🇵🇱 KWANT-LAB PL
EnvironmentAutomotive
KWANT-LAB is a laboratory accredited by PCA under number AB 982 (Poznań, Poland). Its accreditation scope covers 20 test methods in the following areas: Environment, Automotive. Test objects include: Workplace environment − electromagnetic field from equipment used i…, Workplace environment − electromagnetic field originating from indu…, Environment - electromagnetic field in the vicinity of electric pow…, Workplace environment - electromagnetic field from power systems an…. Most frequently used techniques: Direct measurement method.
At a glance
- Accreditation number: PCA AB 982
- Methods in scope: 20
- Types of test objects: 6
- Techniques used: 1
- City: Poznań, Poland
- Accreditation number
- AB 982
- Accreditation body
- PCA
- Address
- Tomasz Kaźmierowski, ul. Pokrzywno 4, 61-315 Poznań
- City
- Poznań, Poland
What this laboratory tests (6)
- Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy units - physiotherapy diathermy units - magnetic resonance scanners — 4 methods
- Workplace environment − electromagnetic field originating from industrial installations and equipment: - arc welding equipment - resistance welding machines - industrial magnetisers and demagnetisers - electrolytic installations - NMR spectrometers - dielectric heating equipment - induction heating equipment - industrial microwave furnaces, heaters and dryers, - equipment for the production and processing of plastics - electric vehicles - soldering equipment - electrical discharge machines - resistance and arc furnaces - electric generators and motors - inverters - special equipment: magnetic separators and industrial static field devices — 4 methods
- Environment - electromagnetic field in the vicinity of electric power substations and power lines — 3 methods
- Workplace environment - electromagnetic field from power systems and AC electrical supply installations in the power industry — 3 methods
- Workplace environment - electromagnetic field in the workspace originating from magnetotherapy or magnetostimulation devices — 3 methods
- Workplace environment − electromagnetic field from radiocommunication and anti-theft systems: - hand-held radiotelephones — 3 methods
Analytical techniques used (1)
- Direct measurement method — 14 methods
Certificate information
- Issue date
- 19.09.2025
- Issue no.
- 22
Accreditation scope — test methods (20)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Workplace environment - electromagnetic field from power systems and AC electrical supply installations in the power industry | Electric field strength: in the frequency range from 10 Hz up to 1 kHz Range 1 V/m – 50 kV/m |
Direct measurement method | Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 91–150 | |
| 2 | Workplace environment - electromagnetic field from power systems and AC electrical supply installations in the power industry | Magnetic flux density: in the frequency range from 10 Hz up to 1 kHz Range 0,023 μT – 19 mT |
Direct measurement method | Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 91–150 | |
| 3 | Workplace environment - electromagnetic field from power systems and AC electrical supply installations in the power industry | Magnetic field strength: in the frequency range from 10 Hz up to 1 kHz (calculated) |
Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 91–150 | ||
| 4 | Workplace environment - electromagnetic field in the workspace originating from magnetotherapy or magnetostimulation devices | Electric field strength: in the frequency range from 10 Hz up to 1 kHz Range 1 V/m – 50 kV/m from 1 kHz up to 100 kHz Range 1 V/m – 20 kV/m |
Direct measurement method | Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 151–180 | |
| 5 | Workplace environment - electromagnetic field in the workspace originating from magnetotherapy or magnetostimulation devices | Magnetic flux density: in the frequency range from 10 Hz up to 1 kHz Range 0,023 μT – 19 mT from 1 kHz up to 100 kHz Range 0,023 μT – 2 mT |
Direct measurement method | Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 151–180 | |
| 6 | Workplace environment - electromagnetic field in the workspace originating from magnetotherapy or magnetostimulation devices | Magnetic field strength: in the frequency range from 10 Hz up to 100 kHz (calculated) |
Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 151–180 | ||
| 7 | Workplace environment − electromagnetic field originating from industrial installations and equipment: - arc welding equipment - resistance welding machines - industrial magnetisers and demagnetisers - electrolytic installations - NMR spectrometers - dielectric heating equipment - induction heating equipment - industrial microwave furnaces, heaters and dryers, - equipment for the production and processing of plastics - electric vehicles - soldering equipment - electrical discharge machines - resistance and arc furnaces - electric generators and motors - inverters - special equipment: magnetic separators and industrial static field devices | Electric field strength: in the frequency range from 10 Hz up to 1 kHz Range 1 V/m − 50 kV/m in the frequency range from 1 kHz up to 100 kHz Range 1 V/m − 20 kV/m in the frequency range from 100 kHz up to 500 kHz Range 1 V/m − 2 kV/m in the frequency range from 100 kHz up to 3 GHz Range (0,84 – 970) V/m |
Direct measurement method | PN-T-06580-3:2002 Method adapted to the regulated area | PB 17-1 issue 3 of 15.05.2025 | |
| 8 | Workplace environment − electromagnetic field originating from industrial installations and equipment: - arc welding equipment - resistance welding machines - industrial magnetisers and demagnetisers - electrolytic installations - NMR spectrometers - dielectric heating equipment - induction heating equipment - industrial microwave furnaces, heaters and dryers, - equipment for the production and processing of plastics - electric vehicles - soldering equipment - electrical discharge machines - resistance and arc furnaces - electric generators and motors - inverters - special equipment: magnetic separators and industrial static field devices | Magnetic flux density: in the frequency range 0 Hz Range (0,125 – 1000) mT from 10 Hz up to 600 kHz Range 0,023 μT – 19 mT |
Direct measurement method | PN-T-06580-3:2002 Method adapted to the regulated area | PB 17-1 issue 3 of 15.05.2025 | |
| 9 | Workplace environment − electromagnetic field originating from industrial installations and equipment: - arc welding equipment - resistance welding machines - industrial magnetisers and demagnetisers - electrolytic installations - NMR spectrometers - dielectric heating equipment - induction heating equipment - industrial microwave furnaces, heaters and dryers, - equipment for the production and processing of plastics - electric vehicles - soldering equipment - electrical discharge machines - resistance and arc furnaces - electric generators and motors - inverters - special equipment: magnetic separators and industrial static field devices | Magnetic field strength: in the frequency range from 0,3 MHz up to 30 MHz Range (0,01 – 16,0) A/m |
Direct measurement method | PN-T-06580-3:2002 Method adapted to the regulated area | PB 17-1 issue 3 of 15.05.2025 | |
| 10 | Workplace environment − electromagnetic field originating from industrial installations and equipment: - arc welding equipment - resistance welding machines - industrial magnetisers and demagnetisers - electrolytic installations - NMR spectrometers - dielectric heating equipment - induction heating equipment - industrial microwave furnaces, heaters and dryers, - equipment for the production and processing of plastics - electric vehicles - soldering equipment - electrical discharge machines - resistance and arc furnaces - electric generators and motors - inverters - special equipment: magnetic separators and industrial static field devices | Magnetic field strength: in the frequency range 0 Hz in the frequency range from 10 Hz up to 600 kHz in the frequency range from 800 MHz up to 3 GHz (calculated) |
PN-T-06580-3:2002 Method adapted to the regulated area | PB 17-1 issue 3 of 15.05.2025 | ||
| 11 | Workplace environment − electromagnetic field from radiocommunication and anti-theft systems: - hand-held radiotelephones | Electric field strength: in the frequency range from 100 kHz up to 3 GHz Range (0,84 – 970) V/m |
Direct measurement method | PN-T-06580-3:2002 Method adapted to the regulated area | PB 17-1 issue 3 of 15.05.2025 | |
| 12 | Workplace environment − electromagnetic field from radiocommunication and anti-theft systems: - hand-held radiotelephones | Magnetic field strength: in the frequency range from 0,3 MHz up to 30 MHz Range (0,01 – 16,0) A/m |
Direct measurement method | PN-T-06580-3:2002 Method adapted to the regulated area | PB 17-1 issue 3 of 15.05.2025 | |
| 13 | Workplace environment − electromagnetic field from radiocommunication and anti-theft systems: - hand-held radiotelephones | Magnetic field strength: in the frequency range from 30 MHz up to 3 GHz (calculated) |
PN-T-06580-3:2002 Method adapted to the regulated area | PB 17-1 issue 3 of 15.05.2025 | ||
| 14 | Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy units - physiotherapy diathermy units - magnetic resonance scanners | Electric field strength: in the frequency range from 10 Hz up to 1 kHz Range 1 V/m − 50 kV/m in the frequency range from 1 kHz up to 100 kHz Range 1 V/m − 20 kV/m in the frequency range from 100 kHz up to 500 kHz Range 1 V/m − 2 kV/m in the frequency range from 100 kHz up to 3 GHz Range (0,84 – 970) V/m |
Direct measurement method | PN-T-06580-3:2002 Method adapted to the regulated area | PB 17-1 issue 3 of 15.05.2025 | |
| 15 | Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy units - physiotherapy diathermy units - magnetic resonance scanners | Magnetic flux density: in the frequency range 0 Hz Range (0,125 – 1000) mT in the frequency range from 10 Hz up to 600 kHz Range 0,023 μT – 19 mT |
Direct measurement method | PN-T-06580-3:2002 Method adapted to the regulated area | PB 17-1 issue 3 of 15.05.2025 | |
| 16 | Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy units - physiotherapy diathermy units - magnetic resonance scanners | Magnetic field strength: in the frequency range from 0,3 MHz up to 30 MHz Range (0,01 – 16,0) A/m |
Direct measurement method | PN-T-06580-3:2002 Method adapted to the regulated area | PB 17-1 issue 3 of 15.05.2025 | |
| 17 | Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy units - physiotherapy diathermy units - magnetic resonance scanners | Magnetic field strength: in the frequency range from 10 Hz up to 600 kHz in the frequency range from 800 MHz up to 3 GHz (calculated) |
PN-T-06580-3:2002 Method adapted to the regulated area | PB 17-1 issue 3 of 15.05.2025 | ||
| 18 | Environment - electromagnetic field in the vicinity of electric power substations and power lines | Electric field strength: in the frequency range from 10 Hz up to 1 kHz Range 1 V/m – 50 kV/m |
Direct measurement method | Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630) | |
| 19 | Environment - electromagnetic field in the vicinity of electric power substations and power lines | Magnetic flux density: in the frequency range from 10 Hz up to 1 kHz Range 0,023 μT – 19 mT |
Direct measurement method | Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630) | |
| 20 | Environment - electromagnetic field in the vicinity of electric power substations and power lines | Magnetic field strength: in the frequency range from 10 Hz up to 1 kHz (calculated) |
Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630) | ||
Reference standards (5)
PB 17-1 issue 3 of 15.05.2025
PN-T-06580-3:2002 Method adapted to the regulated area
Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 151–180
Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 91–150
Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630)