🇵🇱 PRZEDSIĘBIORSTWO PRODUKCYJNO HANDLOWO USŁUGOWE PL
EnvironmentMaterials & polymers
PRZEDSIĘBIORSTWO PRODUKCYJNO HANDLOWO USŁUGOWE is a laboratory accredited by PCA under number AB 976 (Poznań, Poland). Its accreditation scope covers 53 test methods in the following areas: Environment, Materials & polymers. Test objects include: Waste gases, General environment - noise from installations, equipment and indus…, Machinery and equipment - noise, Rooms in buildings – ventilation. Most frequently used techniques: Anemometric method; Thermoanemometric method; Stagnation pressure m…, Direct measurement method, Gravimetric method.
At a glance
- Accreditation number: PCA AB 976
- Methods in scope: 53
- Types of test objects: 4
- Techniques used: 16
- City: Poznań, Poland
- Accreditation number
- AB 976
- Accreditation body
- PCA
- Address
- „BM-EKOS” Sp. z o.o., ul. Sienkiewicza 8/12, 60-817 Poznań
- City
- Poznań, Poland
What this laboratory tests (4)
- Waste gases — 47 methods
- General environment - noise from installations, equipment and industrial plants — 2 methods
- Machinery and equipment - noise — 2 methods
- Rooms in buildings – ventilation — 2 methods
Analytical techniques used (16)
- Anemometric method; Thermoanemometric method; Stagnation pressure method — 2 methods
- Direct measurement method — 2 methods
- Gravimetric method — 2 methods
- Aspiration method using filters — 1 method
- Aspiration method using impingers — 1 method
- Aspiration method using sorbent tubes — 1 method
- Calculation method — 1 method
- Chemiluminescence method — 1 method
- Condensation-adsorption method; Temperature method — 1 method
- Continuous flame ionization detection method (FID) — 1 method
- Electrochemical method; Non-dispersive infrared spectrometry method (NDIR) — 1 method
- Non-dispersive infrared spectrometry (NDIR) — 1 method
- Non-dispersive infrared spectrometry method (NDIR); Chemiluminescence method; Electrochemical method, Paramagnetic method — 1 method
- Paramagnetic method — 1 method
- Stagnation pressure method — 1 method
- and 1 more
Certificate information
- Issue date
- 31.07.2026
- Issue no.
- 28
Accreditation scope — test methods (53)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Waste gases | Gas volume flow rate for dynamic pressures > 10 Pa Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law (consolidated text: Journal of Laws of 2020, item 1219, as amended). |
Stagnation pressure method | PN-Z-04030-7:1994 | |
| 2 | Waste gases | Air stream velocity Range (1,0 – 25) m/s Range (0,15-10) m/s Range (5-800) Pa Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law (consolidated text: Journal of Laws of 2020, item 1219, as amended). |
Anemometric method; Thermoanemometric method; Stagnation pressure method | PN-Z-04030-7:1994 | |
| 3 | Waste gases | Sampling for determination of dust concentration Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law (consolidated text: Journal of Laws of 2020, item 1219, as amended). |
PN-Z-04030-7:1994 | ||
| 4 | Waste gases | Dust concentration Range (0,001 – 100) g/m3 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law (consolidated text: Journal of Laws of 2020, item 1219, as amended). |
Gravimetric method | PN-Z-04030-7:1994 | |
| 5 | Waste gases | Dust emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law (consolidated text: Journal of Laws of 2020, item 1219, as amended). |
PN-Z-04030-7:1994 | ||
| 6 | Waste gases | Sampling for determination of dust concentration Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law (consolidated text: Journal of Laws of 2020, item 1219, as amended). |
PN-EN 13284-1:2018-02 | ||
| 7 | Waste gases | Dust concentration Range (0,0001 – 0,05) g/m3 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law (consolidated text: Journal of Laws of 2020, item 1219, as amended). |
Gravimetric method | PN-EN 13284-1:2018-02 | |
| 8 | Waste gases | Dust emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law (consolidated text: Journal of Laws of 2020, item 1219, as amended). |
PN-EN 13284-1:2018-02 | ||
| 9 | Waste gases | Concentration of sulphur dioxide, carbon dioxide, carbon monoxide, nitrogen monoxide, nitrogen oxides, oxygen SO2 (3 – 3000) mg/m3 CO2 (0,3 – 20) % CO (3 – 2500) mg/m3 NO (2 – 1600) mg/m3 NOx (3 – 2450) mg/m3 O2 (0,2 – 21) % Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law (consolidated text: Journal of Laws of 2020, item 1219, as amended). |
Non-dispersive infrared spectrometry method (NDIR); Chemiluminescence method; Electrochemical method, Paramagnetic method | PN-ISO 10396:2001 | |
| 10 | Waste gases | Emission of SO2, CO, NO, NOx (NO and NO2 calculated as NO2) (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law (consolidated text: Journal of Laws of 2020, item 1219, as amended). |
PN-ISO 10396:2001 | ||
| 11 | Waste gases | Concentration of nitrogen monoxide, nitrogen oxides NO (2 – 1600) mg/m3 NOx (3 – 2450) mg/m3 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law (consolidated text: Journal of Laws of 2020, item 1219, as amended). |
Chemiluminescence method | PN-EN 14792:2017-04 | |
| 12 | Waste gases | NO, NOx emission (NO and NO2 calculated as NO2) (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law (consolidated text: Journal of Laws of 2020, item 1219, as amended). |
PN-EN 14792:2017-04 | ||
| 13 | Waste gases | Carbon monoxide concentration Range (3 – 2500) mg/m3 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law (consolidated text: Journal of Laws of 2020, item 1219, as amended). |
Non-dispersive infrared spectrometry (NDIR) | PN-EN 15058:2017-04 | |
| 14 | Waste gases | Carbon monoxide emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law (consolidated text: Journal of Laws of 2020, item 1219, as amended). |
PN-EN 15058:2017-04 | ||
| 15 | Waste gases | O2 concentration Range (3-21) % Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law (consolidated text: Journal of Laws of 2020, item 1219, as amended). |
Paramagnetic method | PN-EN 14789 :2017-04 | |
| 16 | Waste gases | Water vapour concentration H2O Range (29-250) g/m3 Range (4 – 40) % Range (3,14 – 57) % Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law (consolidated text: Journal of Laws of 2020, item 1219, as amended). |
Condensation-adsorption method; Temperature method | PN-EN 14790 :2017-04 | |
| 17 | Waste gases | Sampling for determination of the concentration of individual gaseous organic compounds Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law (consolidated text: Journal of Laws of 2020, item 1219, as amended). |
PN-EN 13649:2005 | CN/TS 13649:2014 | ||
| 18 | Waste gases | Emission of individual gaseous organic compounds (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law (consolidated text: Journal of Laws of 2020, item 1219, as amended). |
PN-EN 13649:2005 | CN/TS 13649:2014 | ||
| 19 | Waste gases | Concentration of organic substances in the form of gases and vapours expressed as total gaseous organic carbon Range (3,0 – 2000) mg/m3 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law (consolidated text: Journal of Laws of 2020, item 1219, as amended). |
Continuous flame ionization detection method (FID) | PN-EN 12619:2013-05 | |
| 20 | Waste gases | Emission of organic substances in gaseous and vapour form expressed as total gaseous organic carbon (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law (consolidated text: Journal of Laws of 2020, item 1219, as amended). |
PN-EN 12619:2013-05 | ||
| 21 | Waste gases | Sampling for determination of hydrogen chloride concentration Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law (consolidated text: Journal of Laws of 2020, item 1219, as amended). |
PN-EN 1911:2011 | ||
| 22 | Waste gases | HCl emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law (consolidated text: Journal of Laws of 2020, item 1219, as amended). |
PN-EN 1911:2011 | ||
| 23 | Waste gases | Sampling for determination of total mercury concentration Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law (consolidated text: Journal of Laws of 2020, item 1219, as amended). |
PN-EN 13211+AC:2006 | ||
| 24 | Waste gases | Total mercury emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law (consolidated text: Journal of Laws of 2020, item 1219, as amended). |
PN-EN 13211+AC:2006 | ||
| 25 | Waste gases | Sampling for determination of hydrogen fluoride concentration Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law (consolidated text: Journal of Laws of 2020, item 1219, as amended). |
ISO 15713:2006 | ||
| 26 | Waste gases | Emission of the above-mentioned compound (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law (consolidated text: Journal of Laws of 2020, item 1219, as amended). |
CEN/TS 17340:2020-09 | ||
| 27 | Waste gases | Sampling for determination of metal concentrations: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law (consolidated text: Journal of Laws of 2020, item 1219, as amended). |
PN-EN 14385:2025:05 | ||
| 28 | Waste gases | Emission of metals: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law (consolidated text: Journal of Laws of 2020, item 1219, as amended). |
PN-EN 14385:2025:05 | ||
| 29 | Waste gases | Sampling for determination of the concentration of: sulphuric acid aerosol isocyanates fluorides benzo[a]pyrene |
Aspiration method using filters | SOP 305 issue XIII of 01.04.2020 | |
| 30 | Waste gases | Emission of the above-mentioned compounds (calculated) | SOP 305 issue XIII of 01.04.2020 | ||
| 31 | Waste gases | Sampling for determination of the concentration of: acetic acid cresols methanol aldehydes phenol mercaptans amines organic acids lactams |
Aspiration method using sorbent tubes | SOP 306 issue VIII of 07.05.2025 | |
| 32 | Waste gases | Emission of the above-mentioned compounds (calculated) | SOP 306 issue VIII of 07.05.2025 | ||
| 33 | Waste gases | Sampling for determination of SO2 concentration | PN-EN 14791:2017-04 | ||
| 34 | Waste gases | SO2 concentration SO2 (5,0 – 2000) mg/m3 |
Thoron method | PN-EN 14791:2017-04 | |
| 35 | Waste gases | SO2 emission (calculated) | PN-EN 14791:2017-04 | ||
| 36 | Waste gases | Sampling for determination of the concentration of: methanol, ethanol, fluorides ammonia hydrogen sulfide chlorine hydrogen fluoride formaldehyde |
Aspiration method using impingers | SOP 307 issue VIII of 06.04.2020 | |
| 37 | Waste gases | Emission of the above-mentioned compounds (calculated) | SOP 307 issue VIII of 06.04.2020 | ||
| 38 | Waste gases | Concentration of carbon monoxide, sulphur dioxide, nitrogen monoxide, nitrogen dioxide, oxygen, carbon dioxide CO (2 – 2500) mg/m3 SO2 (3 – 2000) mg/m3 NO (4 – 1600) mg/m3 NO2 (4 – 280) mg/m3 O2 (0,2 – 21) % CO2 (0,3 – 20) % |
Electrochemical method; Non-dispersive infrared spectrometry method (NDIR) | PN-ISO 10396:2001 | |
| 39 | Waste gases | Emission of CO, SO2, NO, NO2 (calculated) | PN-ISO 10396:2001 | ||
| 40 | Waste gases | Sampling for determination of metal concentrations in dust | PN-Z-04030-7:1994 | ||
| 41 | Waste gases | Metal emission (calculated) | PN-Z-04030-7:1994 | ||
| 42 | Waste gases | Sampling for determination of PM 2,5 and PM 10 dust concentration | PN-Z-04030-7:1994 | ||
| 43 | Waste gases | PM 2,5 and PM 10 dust emission (calculated) | PN-Z-04030-7:1994 | ||
| 44 | Waste gases | Sampling for determination of ammonia concentration | PN-EN ISO 21877 :2020-03 | ||
| 45 | Waste gases | Emission of NH3 ( calculated) | PN-EN ISO 21877 :2020-03 | ||
| 46 | Waste gases | Sampling for the determination of the concentration of metals: Se, Te, Be, Sn, Zn | PN-EN 14385:2025:05 | ||
| 47 | Waste gases | Emission of metals: Se, Te, Be, Sn, Zn (calculated) | PN-EN 14385:2025:05 | ||
| 48 | Rooms in buildings – ventilation | Air stream velocity Range (1,0 – 25) m/s Range (0,15-10) m/s Range (5 – 800) Pa |
Anemometric method; Thermoanemometric method; Stagnation pressure method | PN-EN 12599:2013-04 | |
| 49 | Rooms in buildings – ventilation | Air volume flow rate, Air change rate (calculated) | PN-EN 12599:2013-04 | ||
| 50 | General environment - noise from installations, equipment and industrial plants | A-weighted equivalent sound pressure level Range (30 – 115) dB |
Direct measurement method | Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023 item 1706) | PN-ISO 9613-2:2002 | |
| 51 | General environment - noise from installations, equipment and industrial plants | A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) | Calculation method | Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023 item 1706) | PN-ISO 9613-2:2002 | |
| 52 | Machinery and equipment - noise | A-frequency-weighted sound pressure level Range (30-115) dB |
Direct measurement method | PN-EN ISO 3746:2011+Ap1:2017-09 excluding cl. 8.4 | |
| 53 | Machinery and equipment - noise | Sound power level (calculated) | PN-EN ISO 3746:2011+Ap1:2017-09 excluding cl. 8.4 | ||
Reference standards (24)
CEN/TS 17340:2020-09
CN/TS 13649:2014
ISO 15713:2006
PN-EN 12599:2013-04
PN-EN 12619:2013-05
PN-EN 13211+AC:2006
PN-EN 13284-1:2018-02
PN-EN 13649:2005
PN-EN 14385:2025:05
PN-EN 14789 :2017-04
PN-EN 14790 :2017-04
PN-EN 14791:2017-04
PN-EN 14792:2017-04
PN-EN 15058:2017-04
PN-EN 1911:2011
PN-EN ISO 21877 :2020-03
PN-EN ISO 3746:2011+Ap1:2017-09 excluding cl. 8.4
PN-ISO 10396:2001
PN-ISO 9613-2:2002
PN-Z-04030-7:1994
SOP 305 issue XIII of 01.04.2020
SOP 306 issue VIII of 07.05.2025
SOP 307 issue VIII of 06.04.2020
Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023 item 1706)