🇵🇱 INSTYTUT PODSTAW INŻYNIERII ŚRODOWISKA PL
EnvironmentWater & wastewater
INSTYTUT PODSTAW INŻYNIERII ŚRODOWISKA is a laboratory accredited by PCA under number AB 950 (Zabrze, Poland). Its accreditation scope covers 65 test methods in the following areas: Environment, Water & wastewater. Test objects include: Waste gases, Automated measuring systems (AMS), Water and wastewater, General environment – ambient air samples collected on filters. Most frequently used techniques: Gravimetric method, Ion chromatography with conductometric detection (IC-CD), Chemiluminescence method (CLD).
At a glance
- Accreditation number: PCA AB 950
- Methods in scope: 65
- Types of test objects: 8
- Techniques used: 21
- City: Zabrze, Poland
- Accreditation number
- AB 950
- Accreditation body
- PCA
- Address
- POLSKIEJ AKADEMII NAUK, LABORATORIUM BADAWCZE, ul. M. Skłodowskiej-Curie 34, 41-819 Zabrze
- City
- Zabrze, Poland
What this laboratory tests (8)
- Waste gases — 36 methods
- Automated measuring systems (AMS) — 14 methods
- Water and wastewater — 7 methods
- General environment – ambient air samples collected on filters — 2 methods
- General environment – waste gas samples collected into absorbing solutions — 2 methods
- Waste gas dedusting equipment — 2 methods
- General environment - dusts in waste gases — 1 method
- General environment – waste gas samples collected on filters, into absorbing solutions and on solid sorbent — 1 method
Analytical techniques used (21)
- Gravimetric method — 5 methods
- Ion chromatography with conductometric detection (IC-CD) — 4 methods
- Chemiluminescence method (CLD) — 3 methods
- Non-dispersive infrared spectrometry (NDIR) — 3 methods
- Paramagnetic method (PMD) — 3 methods
- Condensation - adsorption method — 2 methods
- Fourier transform infrared spectroscopy (FTIR) — 2 methods
- Gas chromatography with mass spectrometry detection (GC-MS) — 2 methods
- Ion chromatography (IC) — 2 methods
- Spectrophotometric method — 2 methods
- Thoron method — 2 methods
- Aspiration method using sorbent tubes — 1 method
- Conductometric method — 1 method
- Continuous flame ionisation detection method (FID) — 1 method
- FTIR method — 1 method
- and 6 more
Laboratory sections (2)
- Laboratory P1 — 53 methods
- Laboratory P2 — 12 methods
Laboratory locations
- INSTYTUT PODSTAW INŻYNIERII ŚRODOWISKA (main site) — ul. M. Skłodowskiej-Curie 34, 41-819 Zabrze
- TESTING LABORATORY — ul. M. Skłodowskiej-Curie 34
- Laboratory P1 — ul. M. Skłodowskiej-Curie 34, 41-819 Zabrze
- Laboratory P2 — ul. M. Skłodowskiej-Curie 34, 41-819 Zabrze
Certificate information
- Issue date
- 21.08.2026
- Issue no.
- 24
Accreditation scope — test methods (65)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Laboratory P1 | |||||
| 1 | Waste gases | Concentration of carbon dioxide, sulphur dioxide, carbon monoxide, nitrogen monoxide, nitrogen dioxide CO2 (0,8 - 24) % SO2 (20 - 1144) mg/m3 CO (10 - 1000) mg/m3 NO (10 - 1072) mg/m3 NO2 (16 - 192) mg/m3 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Fourier transform infrared spectroscopy (FTIR) | PN-ISO 10396:2001 | |
| 2 | Waste gases | Concentration of carbon dioxide, sulphur dioxide, carbon monoxide CO2 (0,8 - 24) % SO2 (20 - 1144) mg/m3 CO (10 - 1000) mg/m3 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Non-dispersive infrared spectrometry (NDIR) | PN-ISO 10396:2001 | |
| 3 | Waste gases | Concentration of nitrogen monoxide, nitrogen oxides NO (10 - 1072) mg/m3 NOx (15 - 1640) mg/m3 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Chemiluminescence method (CLD) | PN-ISO 10396:2001 | |
| 4 | Waste gases | Oxygen concentration Range (0,8 – 25) % Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Paramagnetic method (PMD) | PN-ISO 10396:2001 | |
| 5 | Waste gases | Oxygen concentration Range (0,8 – 25) % Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Zirconia cell method | PN-ISO 10396:2001 | |
| 6 | Waste gases | Emission of NO, NO2, NOx, SO2, CO, CO2 (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-ISO 10396:2001 | ||
| 7 | Waste gases | Gas volume flow rate for dynamic pressures >10Pa Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Stagnation pressure method | PN-Z-04030-07:1994 | |
| 8 | Waste gases | Sampling for determination of dust concentration Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-Z-04030-07:1994 | ||
| 9 | Waste gases | Dust concentration Range (0,001 - 100) g/m3 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Gravimetric method | PN-Z-04030-07:1994 | |
| 10 | Waste gases | Dust emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-Z-04030-07:1994 | ||
| 11 | Waste gases | Concentration of organic substances in the form of gases and vapours expressed as total gaseous organic carbon Range (0,69 – 1000,0) mg/m3 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Continuous flame ionisation detection method (FID) | PN-EN 12619:2013-05 | |
| 12 | Waste gases | Emission of organic substances in gaseous and vapour form expressed as total gaseous organic carbon (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-EN 12619:2013-05 | ||
| 13 | Waste gases | Sampling for the determination of sulfur dioxide concentration Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-EN 14791:2017-04 | ||
| 14 | Waste gases | Sulphur dioxide concentration Range (5 – 2000) mg/m3 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Thoron method | PN-EN 14791:2017-04 | |
| 15 | Waste gases | SO2 emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-EN 14791:2017-04 | ||
| 16 | Waste gases | Oxygen concentration Range (0,8 – 20,9) % Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Paramagnetic method (PMD) | PN-EN 14789:2006 | |
| 17 | Waste gases | Concentration of nitrogen monoxide, nitrogen oxides NO (10,0 – 1071) mg/m3 NOx (9,6 – 1576) mg/m3 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Chemiluminescence method (CLD) | PN-EN 14792:2006 | |
| 18 | Waste gases | NOx emission (calculated as NO2) (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-EN 14792:2006 | ||
| 19 | Waste gases | Sampling for determination of metal concentrations: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-EN 14385:2005 | ||
| 20 | Waste gases | Emission of metals As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-EN 14385:2005 | ||
| 21 | Waste gases | Sampling for determination of hydrogen fluoride concentration Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
ISO 15713:2006 * | ||
| 22 | Waste gases | Hydrogen fluoride emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
ISO 15713:2006 * | ||
| 23 | Waste gases | Sampling for determination of hydrogen chloride concentration Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-EN 1911:2011 * | ||
| 24 | Waste gases | Hydrogen chloride emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-EN 1911:2011 * | ||
| 25 | Waste gases | Water vapour concentration (H2O) Range (4,0 – 40,0) % vol. Range (29 – 250) g/m3 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Condensation - adsorption method | PN-EN 14790:2017-04 | |
| 26 | Automated measuring systems (AMS) | AMS calibration (QAL2) for: SO2, O2, CO2, CO, NO, NOx, dust, H2O Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-EN 14181:2015-02 | ||
| 27 | Automated measuring systems (AMS) | Annual surveillance test (AST) for: SO2, O2, CO2, CO, NO, NOx, dust, H2O Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-EN 14181:2015-02 | ||
| 28 | Automated measuring systems (AMS) | SO2 concentration Range (5 – 2000) mg/m3 Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Thoron method | PN-EN 14791:2017-04 | |
| 29 | Automated measuring systems (AMS) | Concentration of nitrogen monoxide, nitrogen oxides NO (10,0 – 1071) mg/m3 NOx (9,6 – 1576) mg/m3 Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Chemiluminescence method (CLD) | PN-EN 14792:2006 | |
| 30 | Automated measuring systems (AMS) | O2 concentration Range (0,8 – 20,9) % Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Paramagnetic method (PMD) | PN-EN 14789:2006 | |
| 31 | Automated measuring systems (AMS) | Dust concentration Range (0,001 - 100) g/m3 Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Gravimetric method | PN-Z-04030-07:1994 | |
| 32 | Automated measuring systems (AMS) | CO concentration Range (10 - 1000) mg/m3 Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Non-dispersive infrared spectrometry (NDIR) | PN-EN 15058:2006 | |
| 33 | Automated measuring systems (AMS) | Water vapour concentration (H2O) Range (4,0 – 40,0) % vol. Range (29 – 250) g/m3 Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Condensation - adsorption method | PN-EN 14790:2017-04 | |
| 34 | Automated measuring systems (AMS) | Sampling for determination of hydrogen chloride concentration Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-EN 1911:2011 * | ||
| 35 | Automated measuring systems (AMS) | Hydrogen chloride concentration Range (0,42 – 167) mg/m3 Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Ion chromatography (IC) | PN-EN 1911:2011 * | |
| 36 | Waste gases | Emission of dust from the wet coke quenching process | Non-isokinetic Mohrhauer method | Test procedure PB23 issue 5 of 02.01.2024 | |
| 37 | Waste gases | Dust concentration Range (0,007 – 150) g in the sample |
Gravimetric method | Test procedure PB23 issue 5 of 02.01.2024 | |
| 38 | Waste gases | Nitrous oxide concentration Range (19,6 – 235) mg/m3 |
FTIR method | Test procedure PB20 issue 6 of 13.08.2019 | |
| 39 | Waste gases | Sampling for determination of concentrations of organic compounds | Aspiration method using sorbent tubes | Test procedure PB16 issue 6 of 20.02.2024 | |
| 40 | Waste gases | Emission of organic compounds (calculated) | Test procedure PB16 issue 6 of 20.02.2024 | ||
| 41 | Waste gases | Sampling for determination of ammonia concentration | PN-EN ISO 21877:2020-03 | ||
| 42 | Waste gases | Ammonia emission (calculated) | PN-EN ISO 21877:2020-03 | ||
| 43 | Waste gases | Sampling for the determination of H2S concentration | Test procedure PB31 issue 2 of 28.10.2022 | ||
| 44 | Waste gases | H2S emission (calculated) | Test procedure PB31 issue 2 of 28.10.2022 | ||
| 45 | Waste gases | Sampling for the determination of HCN concentration | Test procedure PB31 issue 2 of 28.10.2022 | ||
| 46 | Waste gases | Emission of HCN (calculated) | Test procedure PB31 issue 2 of 28.10.2022 | ||
| 47 | Automated measuring systems (AMS) | Sampling for determination of ammonia concentration | PN-EN ISO 21877:2020-03 * | ||
| 48 | Automated measuring systems (AMS) | Ammonia concentration Range (0,50 – 50) mg/m3 |
Ion chromatography (IC) | PN-EN ISO 21877:2020-03 * | |
| 49 | Automated measuring systems (AMS) | CO2 concentration Range (1 – 24) % |
Fourier transform infrared spectroscopy (FTIR) | PN-ISO 10396:2001 | |
| 50 | Automated measuring systems (AMS) | CO2 concentration Range (0,8 – 24) % |
Non-dispersive infrared spectrometry (NDIR) | PN-ISO 10396:2001 | |
| 51 | General environment - dusts in waste gases | Particle size distribution Range (0,01 - 2100) μm |
Laser beam diffraction method | ISO 13320:2020-01 | |
| 52 | Waste gas dedusting equipment | Dust concentration Range (0,001 – 100) g/m3 |
Gravimetric method | PN-87/M-34129:1987 - Method A | PN-Z-04030-7:1994 | |
| 53 | Waste gas dedusting equipment | Dust removal efficiency (calculated) | PN-87/M-34129:1987 - Method A | PN-Z-04030-7:1994 | ||
| Laboratory P2 | |||||
| 54 | General environment – waste gas samples collected on filters, into absorbing solutions and on solid sorbent | PAH content: naphthalene acenaphthalene acenaphthylene phenanthrene fluoranthene benzo(a)anthracene benzo(k)fluoranthene benzo(a)pyrene benzo(e)pyrene dibenzo(a,h)anthracene fluorene anthracene pyrene chrysene benzo(b)fluoranthene perylene indeno(1,2,3-cd)pyrene benzo(gh)perylene Range (0,03 – 20) μg in the sample |
Gas chromatography with mass spectrometry detection (GC-MS) | Test procedure PB-22 issue 2 of 05.12.2024 | |
| 55 | General environment – waste gas samples collected into absorbing solutions | Ammonia content Range (0,05 – 5,0) mg in the sample Range (1 – 100) mg/L |
Ion chromatography with conductometric detection (IC-CD) | PN-EN ISO 21877:2020-03 | |
| 56 | General environment – waste gas samples collected into absorbing solutions | Hydrogen chloride content Range (0,05 – 20) mg in the sample Range (1 – 400) mg/L |
Ion chromatography with conductometric detection (IC-CD) | PN-EN 1911:2011 * | |
| 57 | General environment – ambient air samples collected on filters | Metal content: As (0,1 – 1000) µg in the sample Cd (0,1 – 1000) µg in the sample Ni (0,3 – 1000) µg in the sample Pb (0,75 – 1000) µg in the sample |
Inductively coupled plasma mass spectrometry (ICP-MS) | PN-EN 14902:2010 | |
| 58 | General environment – ambient air samples collected on filters | PAH content: naphthalene acenaphthalene acenaphthylene phenanthrene fluoranthene benzo(a)anthracene benzo(k)fluoranthene benzo(a)pyrene benzo(e)pyrene dibenzo(a,h)anthracene fluorene anthracene pyrene chrysene benzo(b)fluoranthene perylene indeno(1,2,3-cd)pyrene benzo(gh)perylene Range (0,03 – 20) μg in the sample |
Gas chromatography with mass spectrometry detection (GC-MS) | Test procedure PB-22 issue 2 of 05.12.2024 | |
| 59 | Water and wastewater | Chemical oxygen demand - COD Range (5 – 1000) mg/l O2 |
Spectrophotometric method | PN-ISO 15705:2005 | |
| 60 | Water and wastewater | Total suspended solids (TSS) Range (2 – 500) mg/l |
Gravimetric method | PN-EN 872:2007 | |
| 61 | Water and wastewater | Phosphorus concentration orthophosphates (0,05 – 24) mg/l total phosphorus (0,05 – 48) mg/l |
Spectrophotometric method | PN-EN ISO 6878:2006 +Ap1:2010 +Ap2:2010 | |
| 62 | Water and wastewater | Cation concentrations: Li+ (0,05 – 50) mg/l Na+ (0,5 – 500) mg/l NH4+ (0,1 – 100) mg/l K+ (0,5 – 500) ) mg/l Ca2+ (1 – 1000) ) mg/l Mg2+ (0,5 – 500) ) mg/l |
Ion chromatography with conductometric detection (IC-CD) | PN-EN ISO 14911:2002 | |
| 63 | Water and wastewater | Anion concentrations: Cl- (3 – 3000) mg/l F- (0,1 – 100) mg/l NO2- (0,1 – 100) mg/l NO3- (1 – 1000) ) mg/l PO4- (1 – 100) ) mg/l SO4- (3 – 3000) ) mg/l |
Ion chromatography with conductometric detection (IC-CD) | PN-EN ISO 10304-1:2009 | |
| 64 | Water and wastewater | pH Range 2,0 – 12,0 |
Potentiometric method | PN-EN ISO 10523:2012 | |
| 65 | Water and wastewater | Electrical conductivity Range (84 – 12800) μS/cm |
Conductometric method | PN-EN 27888:1999 | |
Reference standards (30)
ISO 13320:2020-01
ISO 15713:2006 *
PN-87/M-34129:1987 - Method A
PN-EN 12619:2013-05
PN-EN 14181:2015-02
PN-EN 14385:2005
PN-EN 14789:2006
PN-EN 14790:2017-04
PN-EN 14791:2017-04
PN-EN 14792:2006
PN-EN 14902:2010
PN-EN 15058:2006
PN-EN 1911:2011 *
PN-EN 27888:1999
PN-EN 872:2007
PN-EN ISO 10304-1:2009
PN-EN ISO 10523:2012
PN-EN ISO 14911:2002
PN-EN ISO 21877:2020-03
PN-EN ISO 21877:2020-03 *
PN-EN ISO 6878:2006 +Ap1:2010 +Ap2:2010
PN-ISO 10396:2001
PN-ISO 15705:2005
PN-Z-04030-07:1994
PN-Z-04030-7:1994
Test procedure PB-22 issue 2 of 05.12.2024
Test procedure PB16 issue 6 of 20.02.2024
Test procedure PB20 issue 6 of 13.08.2019
Test procedure PB23 issue 5 of 02.01.2024
Test procedure PB31 issue 2 of 28.10.2022