🇵🇱 „EKO-LAB” Sp. z o.o. PL

PCA AB 940 • Wałbrzych, Poland • 193 methods

EnvironmentWater & wastewaterMaterials & polymers

„EKO-LAB” Sp. z o.o. is a laboratory accredited by PCA under number AB 940 (Wałbrzych, Poland). Its accreditation scope covers 193 test methods in the following areas: Environment, Water & wastewater, Materials & polymers. Test objects include: Waste gases, Workplace environment − air, Waste gases - waste gas samples collected on a filter and into abso…, Water, wastewater. Most frequently used techniques: Flame atomic absorption spectrometry (FAAS), Gas chromatography with flame ionization detection (GC-FID), Spectrophotometric method.

At a glance

  • Accreditation number: PCA AB 940
  • Methods in scope: 193
  • Types of test objects: 20
  • Techniques used: 27
  • City: Wałbrzych, Poland
Accreditation number
AB 940
Accreditation body
PCA
Address
ul. Beethovena 1, 58-300 Wałbrzych
City
Wałbrzych, Poland

What this laboratory tests (20)

Analytical techniques used (27)

Laboratory locations

Certificate information

Issue date
17.09.2026
Issue no.
21

Accreditation scope — test methods (193)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Workplace environment − air Sampling for assessment of occupational exposure to: − dust agents
inhalable fraction respirable fraction − organic substances, including inhalable fraction − inorganic substances, including inhalable fraction respirable fraction thoracic fraction − metals and their compounds, including inhalable fraction respirable fraction asbestos − respirable fibres man-made mineral fibres except refractory ceramic fibres − respirable fibres fibrous silicon carbide − respirable fibres
Personal dosimetry method PN-Z-04008-7:2002+Az1:2004
2 Workplace environment − air Sampling for occupational exposure assessment to: − organic substances − inorganic substances Personal dosimetry method; Stationary method PN-Z-04008-7:2002+Az1:2004
3 Workplace environment − air Exposure index (calculated) PN-Z-04008-7:2002+Az1:2004
4 Workplace environment − air Concentration/content of the respirable fraction
crystalline silica (quartz, cristobalite) Range (0,007 - 0,5) mg/m3 Range (0,007 - 0,40) mg in the sample
Fourier transform infrared spectrometry method FT-IR PiMOŚP 2012 No. 4 (74) pp. 117-130
5 Workplace environment − air Concentration of nitrogen monoxide and nitrogen dioxide
NO (0,14 - 17,77) mg/m3 Range (0,112 - 14,28) ppm NO2 (0,04 - 3,55) mg/m3 Range (0,021 - 1,860) ppm
Spectrophotometric method PN-Z-04009-11:2008
6 Workplace environment − air Carbon monoxide concentration
Range (2,3 - 232) mg/m3 Range (2 - 200) ppm
Electrochemical method PB-01 issue 4 of 15.01.2014
7 Workplace environment − air Exposure indices (calculated) PB-01 issue 4 of 15.01.2014
8 Workplace environment − air Ammonia concentration/content
Range (0,23 - 46) mg/m3 Range (0,002 - 6,0) mg in the sample
Spectrophotometric method PN-Z-04041:1971 | PB-10 issue 3 of 03.01.2011
9 Workplace environment − air Chlorine concentration/content
Range (0,07 - 5,0) mg/m3
Spectrophotometric method PN-Z-04037-03:1975
10 Workplace environment − air Concentration of dust agents harmful to health – inhalable fraction:
Apatites and phosphorites Petroleum bitumen Portland cement Titanium dioxide Natural graphite Synthetic graphite Kaolin Amorphous and synthetic silica Wood dusts Flour dusts Dusts not classified according to toxicity Organic dusts of animal and plant origin, except wood and flour dusts Calcium sulfate (VI) (gypsum) Carbon black Man-made mineral fibres except refractory ceramic fibres Talc Coal (hard, brown) Calcium magnesium carbonate (dolomite) Silicon carbide, non-fibrous Fibrous silicon carbide Range (0,13 - 50) mg/m3
Gravimetric method PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08
11 Workplace environment − air Concentration of dust agents harmful to health – respirable fraction:
Apatites and phosphorites Portland cement Natural graphite Amorphous and synthetic silica Organic dusts of animal and plant origin, except wood and flour dusts Talc Coal (hard, brown) Range (0,09 - 7,3) mg/m3
Gravimetric method PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08
12 Workplace environment − air Formaldehyde concentration/content
Range (0,025 - 5,5) mg/m3 Range (0,0003 - 0,8) mg in the sample
Spectrophotometric method PN-Z-04045-02:1976 | PB-24 issue 2 of 03.01.2011
13 Workplace environment − air Ozone concentration
Range (0,025 - 0,25) mg/ m3
Spectrophotometric method PN-Z-04007-2:1994
14 Workplace environment − air Concentration/content of iron oxides calculated as Fe – respirable fraction – inhalable fraction
Range (0,06 - 15,0) mg/m3 Range (0,015 - 6,0) mg in the sample
Flame atomic absorption spectrometry (FAAS) PN-Z-04469:2025-02
15 Workplace environment − air Concentration/content of manganese and its inorganic compounds – expressed as Mn
inhalable fraction respirable fraction Range (0,002 - 12,0) mg/m3 Range (0,002 - 4,8) mg in the sample
Flame atomic absorption spectrometry (FAAS) PN-Z-04472:2015-10
16 Workplace environment − air Concentration/content of nickel and its compounds except nickel tetracarbonyl – calculated as Ni
Range (0,001 - 2,78) mg/m3 Range (0,001 - 2,0) mg in the sample
Flame atomic absorption spectrometry (FAAS) PN-Z 04502:2019-10
17 Workplace environment − air Concentration/content of metallic chromium, chromium compounds: chromium (II), chromium (III), chromium (VI) – calculated as Cr.
Range (0,001 - 2,3) mg/m3 Range (0,004 - 0,92) mg in the sample
Flame atomic absorption spectrometry (FAAS) PN-Z-04434:2011
18 Workplace environment − air Concentration/content of copper and its inorganic compounds – calculated as Cu
Range (0,005 - 2,4) mg/m3 Range (0,0002 - 0,6) mg in the sample
Flame atomic absorption spectrometry (FAAS) PN-Z-04106-3:2002
19 Workplace environment − air Concentration/content of zinc oxide - calculated as Zn – inhalable fraction
Range (0,04 - 8,0) mg/m3 Range (0,004 - 0,8) mg in the sample
Flame atomic absorption spectrometry (FAAS) PN-Z-04100-03:1987
20 Workplace environment − air Concentration/content of lead and its inorganic compounds excluding lead (II) arsenate (V) and lead (II) chromate (VI) calculated as Pb – inhalable fraction
Range (0,001 - 0,4) mg/m3 Range (0,004 - 0,2) mg in the sample
Flame atomic absorption spectrometry (FAAS) PN-ISO 8518:1994
21 Workplace environment − air Aluminium trioxide concentration/content – calculated as Al:
inhalable fraction respirable fraction Range (0,006 - 2,22) mg/m3 Range (0,004 - 1,6) mg in the sample metallic aluminium, aluminium powder (non-stabilised): inhalable fraction respirable fraction Range (0,006 - 2,22) mg/m3 Range (0,004 - 1,6) mg in the sample aluminium hydroxide – calculated as Al: inhalable fraction respirable fraction Range (0,006 - 2,22) mg/m3 Range (0,004 - 1,6) mg in the sample
Flame atomic absorption spectrometry (FAAS) PN-Z-04263-1:2012
22 Workplace environment − air Concentration/content of tin and its inorganic compounds except stannane – calculated as Sn – inhalable fraction
Range (0,06 - 12,0) mg/m3 Range (0,02 - 3,0) mg in the sample
Flame atomic absorption spectrometry (FAAS) PN-Z-04488:2017-10
23 Workplace environment − air Concentration/content of cadmium and its inorganic compounds – calculated as Cd:
inhalable fraction respirable fraction Range (0,001 - 2,5) mg/m3 Range (0,0001 - 0,5) mg in the sample
Flame atomic absorption spectrometry (FAAS) PN-Z-04102-3:2013
24 Workplace environment − air Concentration/content
calcium oxide inhalable fraction respirable fraction Range (0,01 - 8,74) mg/m3 Range (0,002 - 1,75) mg in the sample calcium carbonate (calculated) inhalable fraction Range (0,02 - 15,60) mg/m3 Range (0,003 - 3,12) mg in the sample calcium hydroxide (calculated) inhalable fraction respirable fraction Range (0,013 - 11,55) mg/m3 Range (0,003 - 2,31) mg in the sample
Flame atomic absorption spectrometry (FAAS) PN-Z-04442-10:2023-05
25 Workplace environment − moderate microclimate Air temperature
Range (-10) °C - (+30) °C Black globe temperature Range (-10) °C - (+40) °C Air humidity Range (25 - 75) % Air velocity Range (0,15 - 5) m/s
Direct measurement method PN-EN ISO 7730:2006+Ap2:2016-04
26 Workplace environment − moderate microclimate PMV index, PPD index (calculated) PN-EN ISO 7730:2006+Ap2:2016-04
27 Workplace environment − hot microclimate Air temperature
Range (20 - 40) °C Natural wet bulb temperature Range (10 - 40) °C Black globe temperature Range (20 - 40) °C
Direct measurement method PN-EN ISO 7243:2018-01 +Ap2:2020-04P
28 Workplace environment − hot microclimate WBGT index, WBGTeff index (calculated) PN-EN ISO 7243:2018-01 +Ap2:2020-04P
29 Workplace environment − cold microclimate Air temperature
Range (-20) °C - (+10) °C Black globe temperature Range (-20) °C - (+10) °C Air humidity Range (20 - 80) % Air velocity Range (0,15 - 5,0) m/s
Direct measurement method PN-EN ISO 11079:2008
30 Workplace environment − cold microclimate IREQmin index, IREQneutral index, twc index (calculated) PN-EN ISO 11079:2008
31 Workplace environment − indoor electric lighting Electric lighting illuminance
Range (5 - 9 000) lx
Direct measurement method PB-22 issue 4 of 04.02.2020
32 Workplace environment − indoor electric lighting Uniformity of electric lighting (calculated) PB-22 issue 4 of 04.02.2020
33 Workplace environment − hand-arm vibration Root-mean-square, frequency-weighted vibration acceleration
Range (0,5 - 100) m/s²
Direct measurement method PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11
34 Workplace environment − hand-arm vibration Daily exposure expressed as the 8-hour energy-equivalent vector sum of the effective frequency-weighted vibration accelerations determined for the three directional components (ahwx, ahwy, ahwz) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11
35 Workplace environment − hand-arm vibration Exposure lasting 30 min or less, expressed as the vector sum of the effective frequency-weighted vibration accelerations determined for the three directional components (ahwx, ahwy, ahwz) (calculated) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11
36 Workplace environment − whole-body vibration Root-mean-square, frequency-weighted vibration acceleration
Range (0,07 - 35,5) m/s²
Direct measurement method PN-EN 14253+A1:2011
37 Workplace environment − whole-body vibration Daily exposure expressed as the 8-hour energy-equivalent effective frequency-weighted vibration acceleration, dominant among the vibration accelerations determined for the three directional components, taking into account the appropriate coefficients (1.4awx, 1.4awy, awz) PN-EN 14253+A1:2011
38 Workplace environment − whole-body vibration Exposure lasting 30 min or less, expressed as the effective frequency-weighted vibration acceleration, dominant among the vibration accelerations determined for the three directional components, taking into account the appropriate coefficients (1.4awx, 1.4awy, awz) (calculated) PN-EN 14253+A1:2011
39 Workplace environment − noise A-weighted equivalent sound pressure level PN-N-01307:1994 | PN-EN ISO 9612:2025-11 excluding the method covering strategy 2 - cl. 10 and strategy 3 - cl. 11
40 Workplace environment − noise Maximum A-weighted sound pressure level
Range (25 - 135) dB
PN-N-01307:1994 | PN-EN ISO 9612:2025-11 excluding the method covering strategy 2 - cl. 10 and strategy 3 - cl. 11
41 Workplace environment − noise C-weighted peak sound pressure level
Range (50 - 138) dB
Direct measurement method PN-N-01307:1994 | PN-EN ISO 9612:2025-11 excluding the method covering strategy 2 - cl. 10 and strategy 3 - cl. 11
42 Workplace environment − noise Noise exposure level referred to: PN-N-01307:1994 | PN-EN ISO 9612:2025-11 excluding the method covering strategy 2 - cl. 10 and strategy 3 - cl. 11
43 Workplace environment − noise − for an 8-h daily working time PN-N-01307:1994 | PN-EN ISO 9612:2025-11 excluding the method covering strategy 2 - cl. 10 and strategy 3 - cl. 11
44 Workplace environment − noise − the average weekly working time (calculated) PN-N-01307:1994 | PN-EN ISO 9612:2025-11 excluding the method covering strategy 2 - cl. 10 and strategy 3 - cl. 11
45 Workplace environment − noise (selection of hearing protectors) Equivalent sound pressure level in octave frequency bands
Range (63 - 8000) Hz Range (50 - 135) dB
PN-EN ISO 9612:2025-11 | PN-EN 458:2016-06 | PN-EN ISO 4869-2:2018-2
46 Workplace environment − noise (selection of hearing protectors) A-weighted equivalent sound pressure level PN-EN ISO 9612:2025-11 | PN-EN 458:2016-06 | PN-EN ISO 4869-2:2018-2
47 Workplace environment − noise (selection of hearing protectors) Equivalent C-weighted sound level
Range (50 - 138) dB
Direct measurement method PN-EN ISO 9612:2025-11 | PN-EN 458:2016-06 | PN-EN ISO 4869-2:2018-2
48 Workplace environment − noise (selection of hearing protectors) A-weighted equivalent sound level under hearing protectors (calculated) PN-EN ISO 9612:2025-11 | PN-EN 458:2016-06 | PN-EN ISO 4869-2:2018-2
49 General environment − noise from installations, or equipment and industrial plants A-weighted equivalent sound pressure level
Range (25 - 130) dB
Direct measurement method Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023 item 1706) - excluding cl. F
50 General environment − noise from installations, or equipment and industrial plants A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023 item 1706) - excluding cl. F
51 Workplace environment – emergency lighting Electric lighting illuminance
Range (0,5 - 500) lx
Direct measurement method PN-EN 1838:2025-05 excluding cl. 5.1.3, 5.1.4, 5.1.7, 5.1.8, 5.2.3, 5.2.4, 5.2.7, 5.3.4, 5.3.5, 5.3.7, 5.3.8, 6, 7
52 Workplace environment – emergency lighting Ratio of minimum to maximum illuminance Ud (calculated) PN-EN 1838:2025-05 excluding cl. 5.1.3, 5.1.4, 5.1.7, 5.1.8, 5.2.3, 5.2.4, 5.2.7, 5.3.4, 5.3.5, 5.3.7, 5.3.8, 6, 7
53 Workplace environment – emergency lighting Closing time
Range (0,5 - 80) s
Direct measurement method PN-EN 1838:2025-05 excluding cl. 5.1.3, 5.1.4, 5.1.7, 5.1.8, 5.2.3, 5.2.4, 5.2.7, 5.3.4, 5.3.5, 5.3.7, 5.3.8, 6, 7
54 Workplace environment – emergency lighting Operation time
Range (1 - 60) min
Direct measurement method PN-EN 1838:2025-05 excluding cl. 5.1.3, 5.1.4, 5.1.7, 5.1.8, 5.2.3, 5.2.4, 5.2.7, 5.3.4, 5.3.5, 5.3.7, 5.3.8, 6, 7
55 Working environment - electromagnetic field from industrial installations and equipment: - arc welding equipment - resistance welders - induction heating equipment - electric vehicles - soldering equipment - electrical discharge machines - resistance and arc furnaces - generators and electric motors - inverters Electric field strength:
in the frequency range from 10 Hz to 400 kHz Range (1 – 50000) V/m
Direct measurement method PB-09 issue 1 of 07.04.2026
56 Working environment - electromagnetic field from industrial installations and equipment: - arc welding equipment - resistance welders - induction heating equipment - electric vehicles - soldering equipment - electrical discharge machines - resistance and arc furnaces - generators and electric motors - inverters Magnetic flux density:
in the frequency range from 10 Hz to 400 kHz Range (1 – 19000) μT
Direct measurement method PB-09 issue 1 of 07.04.2026
57 Working environment - electromagnetic field from industrial installations and equipment: - arc welding equipment - resistance welders - induction heating equipment - electric vehicles - soldering equipment - electrical discharge machines - resistance and arc furnaces - generators and electric motors - inverters Magnetic field strength (calculated)
in the frequency range from 10 Hz to 400 kHz
PB-09 issue 1 of 07.04.2026
58 Waste gases Gas volume flow rate for dynamic pressures > 5 Pa
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Stagnation pressure method PN-Z-04030-7:1994
59 Waste gases Velocity
Range (1,0 - 6,0) m/s
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Anemometric method PN-Z-04030-7:1994
60 Waste gases Sampling for determination of dust concentration
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
PN-Z-04030-7:1994
61 Waste gases Dust concentration
Range (0,0005 - 9,5) g/m3
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Gravimetric method PN-Z-04030-7:1994
62 Waste gases Dust emission (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
PN-Z-04030-7:1994
63 Waste gases Sampling for determination of dust concentration
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
PN-EN 13284-1:2018-02
64 Waste gases Dust concentration
Range (0,0002 - 0,1) g/m3
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Gravimetric method PN-EN 13284-1:2018-02
65 Waste gases Dust emission (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
PN-EN 13284-1:2018-02
66 Waste gases Sulphur dioxide concentration
Range (3 - 1700) mg/m3
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Non-dispersive infrared spectrometry NDIR PN-ISO 10396:2001
67 Waste gases SO2 emission (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
PN-ISO 10396:2001
68 Waste gases Carbon monoxide concentration
Range (1 - 5300) mg/m3
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Non-dispersive infrared spectrometry NDIR PN-ISO 10396:2001 | PN-EN 15058:2017-4
69 Waste gases CO emission (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
PN-ISO 10396:2001 | PN-EN 15058:2017-4
70 Waste gases Carbon dioxide concentration
Range (0,1 - 20,0) %
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Non-dispersive infrared spectrometry NDIR PN-ISO 10396:2001 | ISO 12039:2019
71 Waste gases CO2 emission (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
PN-ISO 10396:2001 | ISO 12039:2019
72 Waste gases Nitrogen oxide concentration
Range (1 - 600) mg/m3
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Chemiluminescence method PN-ISO 10396:2001 | PN-EN 14792:2017-4
73 Waste gases Nitrogen oxides concentration
Range (2 - 900) mg/m3
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Chemiluminescence method PN-ISO 10396:2001 | PN-EN 14792:2017-4
74 Waste gases Emission of NO and NOx (NO and NO2 calculated as NO2) (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
PN-ISO 10396:2001 | PN-EN 14792:2017-4
75 Waste gases Oxygen concentration
Range (1,0 - 21,0) %
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Paramagnetic method PN-ISO 10396:2001 | PN-EN 14789:2017-4
76 Waste gases Oxygen concentration
Range (1,0 - 21,0) %
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Electrochemical method PN-ISO 10396:2001
77 Waste gases Sampling for determination of hydrogen chloride concentration
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
PN-EN 1911:2011
78 Waste gases Hydrogen chloride concentration/content
Range (0,95 - 166) mg/m3 Range (0,057 - 10) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Spectrophotometric method PN-EN 1911:2011
79 Waste gases Hydrogen chloride emission (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
PN-EN 1911:2011
80 Waste gases Sampling for determination of hydrogen fluoride concentration
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
ISO 15713:2006
81 Waste gases Hydrogen fluoride concentration
Range (0,1 - 190) mg/m3
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Potentiometric method ISO 15713:2006
82 Waste gases Hydrogen fluoride emission (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
ISO 15713:2006
83 Waste gases Sampling for determination of the concentration of individual gaseous organic compounds.
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Aspiration method using absorption tubes PN-EN 13649:2005
84 Waste gases Emission of individual gaseous organic compounds (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
PN-EN 13649:2005
85 Waste gases Sampling for determination of the concentrations of organic compounds.
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Aspiration method using activated carbon / silica gel / absorbing solutions PN-Z-04008-4:1999
86 Waste gases Emission of organic compounds (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
PN-Z-04008-4:1999
87 Waste gases Concentration of organic substances in the form of gases and vapours expressed as total gaseous organic carbon
Range (1,0 - 1000) mg/m3
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Continuous flame ionization detection method (FID) PN-EN 12619:2013
88 Waste gases Emission of organic substances in gaseous and vapour form expressed as total gaseous organic carbon (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
PN-EN 12619:2013
89 Waste gases Sampling for determination of sulfur dioxide concentration SO2
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
PN-EN 14791:2017-04
90 Waste gases Concentration/content of sulphur dioxide SO2
Range (1,11 - 2320) mg/m3 Range (0,1 - 209) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Thoron method PN-EN 14791:2017-04
91 Waste gases Emission of sulphur dioxide SO2 (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
PN-EN 14791:2017-04
92 Waste gases Water vapour concentration (H2O)
Range (23 - 250 g/m3 Range (3,0 - 40,0) % Range (3,0 - 57,0) %
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Condensation-adsorption method; Temperature method PN-EN 14790:2017-04
93 Waste gases - waste gas samples collected on a filter and into absorbing solution Sampling for determination of metal concentrations: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
PN-EN 14385:2025-05
94 Waste gases - waste gas samples collected on a filter and into absorbing solution Concentration/content of manganese
Range (0,0003 - 48,0) mg/m3 Range (0,001 - 24,0) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Flame atomic absorption spectrometry (FAAS) PN-EN 14385:2025-05
95 Waste gases - waste gas samples collected on a filter and into absorbing solution Concentration/content of nickel
Range (0,002 - 20,0) mg/m3 Range (0,004 - 10,0) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Flame atomic absorption spectrometry (FAAS) PN-EN 14385:2025-05
96 Waste gases - waste gas samples collected on a filter and into absorbing solution Concentration/content of copper
Range (0,0001 - 6,0) mg/m3 Range (0,0002 - 3,0) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Flame atomic absorption spectrometry (FAAS) PN-EN 14385:2025-05
97 Waste gases - waste gas samples collected on a filter and into absorbing solution Concentration/content of lead
Range (0,0004 - 4,0) mg/m3 Range (0,001 - 2,0) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Flame atomic absorption spectrometry (FAAS) PN-EN 14385:2025-05
98 Waste gases - waste gas samples collected on a filter and into absorbing solution Concentration/content of cobalt
Range (0,0004 - 5,0) mg/m3 Range (0,002 - 2,5) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Flame atomic absorption spectrometry (FAAS) PN-EN 14385:2025-05
99 Waste gases - waste gas samples collected on a filter and into absorbing solution Concentration/content of cadmium
Range (0,0001 - 0,7) mg/m3 Range (0,0002 - 2,5) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Flame atomic absorption spectrometry (FAAS) PN-EN 14385:2025-05
100 Waste gases - waste gas samples collected on a filter and into absorbing solution Concentration/content of chromium
Range (0,0005 - 18,4) mg/m3 Range (0,001 - 9,2) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Flame atomic absorption spectrometry (FAAS) PN-EN 14385:2025-05
101 Waste gases - waste gas samples collected on a filter and into absorbing solution Emission of metals: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
PN-EN 14385:2025-05
102 Waste gases - waste gas samples collected on a filter and into absorbing solution Sampling for determination of total mercury concentration
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
PN-EN 13211:2006
103 Waste gases - waste gas samples collected on a filter and into absorbing solution Total mercury concentration
Range (0,0033 - 770,0) µg/m3 Range (0,007 - 87,5) µg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Cold vapour atomic absorption spectrometry (CVAAS) PN-EN 13211:2006
104 Waste gases - waste gas samples collected on a filter and into absorbing solution Total mercury concentration (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
PN-EN 13211:2006
105 Waste gases Sampling of PM10; PM2,5 dust for testing PN-EN ISO 23210:2010
106 Waste gases PM10; PM2,5 dust concentration
Range (0,0005 ÷ 0,04) g/m3
Gravimetric method PN-EN ISO 23210:2010
107 Waste gases Emission of dust PM10/PM2,5 (calculated) PN-EN ISO 23210:2010
108 Waste gases Waste gas sampling for determination of formaldehyde, ammonia, MDI, TDI, ozone, sulfuric acid, chlorine PB-47 issue 4 of 27.07.2026
109 Waste gases Formaldehyde concentration/content
Range (0,07 - 100) mg/m3 Range (0,001 - 0,8) mg in the sample
Spectrophotometric method PB-24 issue 2 of 03.01.2011
110 Waste gases Sulfuric(VI) acid concentration/content
Range (0,1 - 200) mg/m3 Range (0,12 - 20,0) mg in the sample
Turbidimetric method PB-26 issue 2 of 03.01.2011
111 Waste gases Ammonia concentration/content
Range (0,23 - 230) mg/m3 Range (0,003 - 6,0) mg in the sample
Spectrophotometric method PB-10 issue 3 of 03.01.2011
112 Waste gases Ozone concentration
Range (0,025 - 0,25) mg/ m3
Spectrophotometric method PB-34 issue 1 of 10.05.2010
113 Waste gases Concentration/content of methylenebis(phenyl isocyanate)
Range (0,014 - 3,33) mg/m3 Range (0,001 - 0,5) mg in the sample
Spectrophotometric method PB- 08 issue 3 of 03.01.2011
114 Waste gases Emission of formaldehyde, ammonia, MDI, TDI, ozone, sulphuric acid. (calculated) PB-47 issue 4 of 27.07.2026
115 Waste gases Sampling for determination of metals in PM10; PM2,5 dust PN-EN ISO 23210:2010
116 Waste gases Emission of metals in dust PM10; PM2,5 (calculated) PN-EN ISO 23210:2010
117 Waste gases Gas volume flow rate for dynamic pressures > 5 Pa Differential pressure measurement method PN-EN ISO 16911-1:2013
118 Waste gases Velocity
Range (1,0 - 6,0) m/s
Anemometric method PN-EN ISO 16911-1:2013
119 Waste gases Chlorine concentration Cl
Range (0,03 - 5,0) mg/m3
Spectrophotometric method PB-04 issue 1 of 01.09.2020
120 Waste gases Emission of chlorine Cl (calculated) PB-04 issue 1 of 01.09.2020
121 Waste gases Sampling for determination of ammonia concentration NH3 PN-EN ISO 21877:2020-03
122 Waste gases Ammonia NH3 concentration
Range (0,08 - 32,0) mg/m3
Spectrophotometric method PN-EN ISO 21877:2020-03
123 Waste gases Ammonia NH3 emission (calculated) PN-EN ISO 21877:2020-03
124 Waste gases Sampling for the determination of PCDD/PCDF mass concentration PN-EN 1948-1:2006
125 Waste gases PCDD/PCDF emission (calculated) PN-EN 1948-1:2006
126 Waste gases - waste gas samples collected on a filter and into absorbing solution Sampling for the determination of metals As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V, Fe, Zn, Al., Sn, Ca, Na, K PN-EN 14385:2025-05
127 Waste gases - waste gas samples collected on a filter and into absorbing solution Iron concentration/content
Range (0,0007 - 8,0) mg/m3 Range (0,002 - 40,0) mg in the sample
Flame atomic absorption spectrometry (FAAS) PN-EN 14385:2025-05
128 Waste gases - waste gas samples collected on a filter and into absorbing solution Concentration/content of zinc
Range (0,0005 - 16,0) mg/m3 Range (0,002 - 8,0) mg in the sample
Flame atomic absorption spectrometry (FAAS) PN-EN 14385:2025-05
129 Waste gases - waste gas samples collected on a filter and into absorbing solution Aluminium concentration/content
Range (0,006 - 32,0) mg/m3 Range (0,02 - 16,0) mg in the sample
Flame atomic absorption spectrometry (FAAS) PN-EN 14385:2025-05
130 Waste gases - waste gas samples collected on a filter and into absorbing solution Concentration/content of tin
Range (0,01 - 60,0) mg/m3 Range (0,03 - 30,0) mg in the sample
Flame atomic absorption spectrometry (FAAS) PN-EN 14385:2025-05
131 Waste gases - waste gas samples collected on a filter and into absorbing solution Concentration/content of calcium
Range (0,0002 - 9,98) mg/m3 Range (0,006 - 13,0) mg in the sample
Flame atomic absorption spectrometry (FAAS) PN-EN 14385:2025-05
132 Waste gases - waste gas samples collected on a filter and into absorbing solution Concentration/content of sodium
Range (0,001 - 14,0) mg/m3 Range (0,005 - 0,42) mg in the sample
Flame atomic absorption spectrometry (FAAS) PN-EN 14385:2025-05
133 Waste gases - waste gas samples collected on a filter and into absorbing solution Concentration/content of potassium
Range (0,0002 - 30,6) mg/m3 Range (0,001 - 0,92) mg in the sample
Flame atomic absorption spectrometry (FAAS) PN-EN 14385:2025-05
134 Waste gases - waste gas samples collected on a filter and into absorbing solution Emission of metals As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V, Fe, Zn, Al, Sn, Ca, Na, K (calculated) PN-EN 14385:2025-05
135 Water, wastewater pH
Range 4,0 - 12,0
Potentiometric method PN-EN ISO 10523:2012
136 Water, wastewater Biochemical oxygen demand - BOD5
Range (3 - 6000) mg/l O2
Electrochemical method PN-EN ISO 5815-1:2019-12
137 Water, wastewater Chemical oxygen demand - COD
Range (30 - 7000) mg/l O2
Titrimetric method PN-ISO 6060:2006
138 Water, wastewater Chemical oxygen demand - COD
Range (10 - 1500) mg/l O2
Spectrophotometric method PB-45 issue 1 of 15.12.2016 based on the Merck cuvette test 1.14540
139 Water, wastewater Dry residue
Range (5 - 3000) mg/l Dissolved solids Range (5 - 3000) mg/l
Gravimetric method PN-C-04541:1978
140 Water, wastewater Total suspended solids (TSS)
Range (2,0 - 1000) mg/l
Gravimetric method PN-EN 872:2007 + Ap1:2007
141 Water, wastewater Silica concentration
Range (0,005 - 4,0) mg/l
Spectrophotometric method PB-11 issue 2 of 09.01.2009 | based on Nanocolor test 1-48
142 Water, wastewater Electrical conductivity
Range (10 - 1999) μS/cm
Conductometric method PN-EN 27888:1999
143 Water, wastewater Total nitrogen concentration
Range (0,5 - 150) mg/l
Spectrophotometric method PB-27 issue 1 of 07.01.2010 | based on Merck test 1.14537 and 1.14763
144 Water, wastewater Iron concentration
Range (0,01 - 50,0) mg/l
Flame atomic absorption spectrometry (FAAS) PB-41 issue 3 of 09.01.2012
145 Water, wastewater Manganese concentration
Range (0,006 - 30,0) mg/l
Flame atomic absorption spectrometry (FAAS) PB-41 issue 3 of 09.01.2012
146 Water, wastewater Lead concentration
Range (0,04 - 50) mg/l
Flame atomic absorption spectrometry (FAAS) PN-ISO 8288:2002; Method A
147 Water, wastewater Nickel concentration
Range (0,01 - 50) mg/l
Flame atomic absorption spectrometry (FAAS) PN-ISO 8288:2002; Method A
148 Water, wastewater Cobalt concentration
Range (0,03 - 50) mg/l
Flame atomic absorption spectrometry (FAAS) PN-ISO 8288:2002; Method A
149 Water, wastewater Zinc concentration
Range (0,05 - 10) mg/l
Flame atomic absorption spectrometry (FAAS) PN-ISO 8288:2002; Method A
150 Water, wastewater Copper concentration
Range (0,005 - 30) mg/l
Flame atomic absorption spectrometry (FAAS) PN-ISO 8288:2002; Method A
151 Water, wastewater Cadmium concentration
Range (0,004 - 50) mg/l
Flame atomic absorption spectrometry (FAAS) PN-ISO 8288:2002; Method A
152 Water, wastewater Chromium concentration
Range (0,01 - 60) mg/l
Flame atomic absorption spectrometry (FAAS) PN-EN 1233:2000
153 Water, wastewater Dissolved oxygen concentration
Range (0,5 - 15,0) mg/l O2
Electrochemical method PB-07 issue 2 of 09.01.2009
154 Wastewater Sampling for physical and chemical testing Manual and automatic method PN-ISO 5667-10:2021-11
155 Wastewater Temperature of wastewater and of the collected wastewater sample
Range (0,0 - 50,0) ºC
PN-C-04584:1977
156 Wastewater Phenol concentration
Range (0,1 - 2,5) mg/l
Spectrophotometric method PB-28 issue 1 of 07.01.2010 | based on Merck test 1.14551
157 Surface waters Sampling for physical and chemical testing PN-EN ISO 5667-6:2016-12 excluding cl. 7.4, 7.5, 7.6
158 Surface waters Temperature of water and of the collected water sample
Range (0,0 - 50,0) ºC
PN-C-04584:1977
159 Process waters Sampling for physical and chemical testing PB-35 issue 1 of 10.05.2010
160 Process waters Temperature of water and of the collected water sample
Range (0,0 - 50,0) ºC
PN-C-04584:1977
161 Water intended for consumption Sampling for physical, chemical testing PN-ISO 5667-5:2017-10
162 Water intended for consumption Temperature of water and of the collected water sample
Range (0,0 - 50,0) ºC
PN-C-04584:1977
163 Water intended for consumption Sampling for microbiological testing PN-EN ISO 19458:2007
Chromatography Laboratory; "Jedlina Branch"
164 Workplace environment − air Concentration of organic compounds
Hexane (6,5 - 260) mg/m3 Acetone (20,0 - 2540) mg/m3 Ethyl acetate (10,0 - 1560) mg/m3 Range (2,74 - 427,2) ppm n-butyl acetate (10,0 - 1056) mg/m3 Toluene (8,0 - 350) mg/m3 Xylene - mixture of isomers: 1,2-; 1,3-; 1,4- (8,0 - 340) mg/m3 Ethanol (50,0 - 2520) mg/m3 Butan-2-one (10,0 - 966) mg/m3 4-methylpentan-2-one (8,0 - 320) mg/m3
Gas chromatography with flame ionization detection (GC-FID) PB-13 issue 5 of 22.04.2024
165 Workplace environment − air Concentration of organic compounds
Dichloromethane (6,2 - 550) mg/m3 Range (1,76 - 156,1) ppm Trichloroethene (6,4 - 290) mg/m3 Tetrachloroethene (6,8 - 320) mg/m3 Range (0,98 - 46,5) ppm
Gas chromatography with flame ionization detection (GC-FID) PB-14 issue 5 of 22.04.2024
166 Workplace environment − air Concentration of organic compounds
Propan-2-ol (50,0 - 1258) mg/m3 Butan-2-ol (10,0 - 648) mg/m3 Propan-1-ol (10,0 - 640) mg/m3 2-Methylpropan-1-ol (8,0 - 320) mg/m3 Butan-1-ol (4,0 - 160) mg/m3
Gas chromatography with flame ionization detection (GC-FID) PB-15 issue 5 of 29.08.2023
167 Workplace environment − air Concentration of organic compounds
Ethylbenzene (10,0 - 696) mg/m3 Cumene (7,5 - 340) mg/m3 1,3,5- trimethylbenzene (8,0 - 340) mg/m3 1,2,4- trimethylbenzene (8,0 - 350) mg/m3 1,2,3- trimethylbenzene (8,0 - 350) mg/m3
Gas chromatography with flame ionization detection (GC-FID) PB-16 issue 5 of 22.04.2024
168 Workplace environment − air Concentration of organic compounds
1-methoxypropan-2-ol (10,0 - 550) mg/m3 2-Methoxy-1-methylethyl acetate (10,0 - 776) mg/m3 Cyclohexanone (3,0 - 190) mg/m3 2-butoxyethanol (7,7 - 360) mg/m3 2-butoxyethyl acetate (8,2 - 370) mg/m3
Gas chromatography with flame ionization detection (GC-FID) PB-17 issue 5 of 22.04.2024
169 Workplace environment − air Styrene concentration
Range (4,0 - 180,0) mg/m3
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04152-02:1986 | PB-19 issue 5 of 22.04.2024
170 Workplace environment − air Extraction naphtha concentration
Range (20,0 - 1222) mg/m3 Benzene concentration Range (0,05 - 15,0) mg/m3 Range (0,015 - 4,63) ppm
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04134-02:1981 | PB-18 issue 3 of 22.04.2024
171 Workplace environment − air Vinyl acetate concentration
Range ( 0,21 - 124,0 ) mg/m3
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04178-02:1987
172 Workplace environment − air Kerosene concentration
Range (0,625 - 400,0 ) mg/m3
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04227-02:1992
173 Workplace environment − air Phenol concentration
Range (0,625 - 20,0 ) mg/m3
Gas chromatography with flame ionization detection (GC-FID) PB-29 issue 2 of 22.04.2024
174 Workplace environment − air Pentane concentration
Range (0,21 - 3060 ) mg/m3
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04318:2005
175 Workplace environment − air Acrylaldehyde concentration
Range (0,004 - 20,0) mg/m3 Range (0,0017 - 8,61) ppm
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04045-06:1982
176 Workplace environment − air Turpentine concentration
Range (11 - 600) mg/m3
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04333:2006
177 Workplace environment − air Ethylene glycol concentration
Range (0,5 - 150) mg/m3
Gas chromatography with flame ionization detection (GC-FID) PB-43 issue 3 of 22.04.2024
178 Waste gases Concentration of organic compounds
Hexane (0,067 - 86,67) mg/m3 Acetone (0,067 - 210,00) mg/m3 Ethyl acetate (0,067 - 120,00) mg/m3 n-butyl acetate (0,067 - 116,67) mg/m3 Toluene (0,067 - 113,33) mg/m3 Xylene - mixture of isomers: 1,2-; 1,3-; 1,4- (0,067 - 113,33) mg/m3 Ethanol (0,100 - 210,00) mg/m3 Butan-2-one (0,067 - 106,67) mg/m3 4-methylpentan-2-one (0,067 - 106,67) mg/m3 Dichloromethane (0,067 - 86,67) mg/m3 Trichloroethene (0,067 - 96,67) mg/m3 Tetrachloroethene (0,067 - 106,67) mg/m3 Propan-2-ol (0,067 - 200,00) mg/m3 Butan-2-ol (0,067 - 106,67) mg/m3 Propan-1-ol (0,067 - 106,67) mg/m3 2-Methylpropan-1-ol (0,067 - 106,67) mg/m3 Butan-1-ol (0,067 - 67,00) mg/m3 Ethylbenzene (0,067 - 113,33) mg/m3 Cumene (0,067 - 113,33) mg/m3 1,3,5- trimethylbenzene (0,067 - 113,33) mg/m3 1,2,4- trimethylbenzene (0,067 - 113,33) mg/m3 1,2,3- trimethylbenzene (0,067 - 113,33) mg/m3 1-Methoxypropan-2-ol (0,133 - 120,00) mg/m3 2-Methoxy-1-methylethyl acetate (0,100 - 126,67) mg/m3 Cyclohexanone (0,100 - 60,00) mg/m3 2-butoxyethanol (0,100 - 120,00) mg/m3 2-butoxyethyl acetate (0,100 - 120,00) mg/m3 Styrene (0,033 - 60,00) mg/m3 Extraction naphtha (0,067 - 180,00) mg/m3 Benzene (0,033 - 5,67) mg/m3
Regulated area: The method is applicable as a reference method in the regulated area (see page 11)
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005 * | PB-23 issue 3 of 22.04.2024
179 Waste gases Phenol concentration
Range (0,5 - 105) mg/m3
Regulated area: The method is applicable as a reference method in the regulated area (see page 11)
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04008-4:1999 * | PB-29 issue 2 of 22.04.2024
180 Waste gases Concentration of aliphatic hydrocarbons (C4 – C10) in air
Range (0,66 - 233,0) mg/m3
Regulated area: The method is applicable as a reference method in the regulated area (see page 11)
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005 * | PB-36 issue 2 of 22.04.2024
181 Waste gases Kerosene concentration
Range (0,83 - 200,0) mg/m3
Regulated area: The method is applicable as a reference method in the regulated area (see page 11)
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005 * | PB-32 issue 2 of 22.04.2024
182 Waste gases Vinyl acetate concentration
Range (0,40 - 310) mg/m3
Regulated area: The method is applicable as a reference method in the regulated area (see page 11)
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005 * | PB-31 issue 2 of 22.04.2024
183 Waste gases Pentane concentration
Range (0,90 - 340) mg/m3
Regulated area: The method is applicable as a reference method in the regulated area (see page 11)
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005 * | PB-33 issue 2 of 22.04.2024
184 Waste gases Turpentine concentration
Range (2,72 - 600) mg/m3
Regulated area: The method is applicable as a reference method in the regulated area (see page 11)
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005 * | PB-42 issue 2 of 22.04.2024
185 Waste gases Ethylene glycol concentration
Range (0,5 - 50) mg/m3
Regulated area: The method is applicable as a reference method in the regulated area (see page 11)
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005 * | PB-43 issue 3 of 22.04.2024
186 Workplace environment − air samples collected on sorbent tubes, General environment - waste gas samples collected on sorbent tubes Phenol content
Range (0,015 - 0,50) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PB-29 issue 2 of 22.04.2024
187 Workplace environment − air samples collected on sorbent tubes, General environment - waste gas samples collected on sorbent tubes Content of aliphatic hydrocarbons (C4 – C10) in air
Range (0,020 - 0,7) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04017-03:1990 excluding cl. 8
188 Workplace environment − air samples collected on sorbent tubes, General environment - waste gas samples collected on sorbent tubes Kerosene content
Range (0,015 - 1,0) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04227-02:1992 excluding cl. 8
189 Workplace environment − air samples collected on sorbent tubes, General environment - waste gas samples collected on sorbent tubes Vinyl acetate content
Range (0,005 - 0,93) mg in the sample
Gas chromatography with flame ionization detection (GC-FID PN-Z-04178-02:1987 excluding cl. 8
190 Workplace environment − air samples collected on sorbent tubes, General environment - waste gas samples collected on sorbent tubes Pentane content
Range (0,005 - 1,02 ) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04318:2005 excluding cl. 8
191 Workplace environment − air samples collected on sorbent tubes, General environment - waste gas samples collected on sorbent tubes Turpentine content
Range (0,082 - 3,0) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PB-42 issue 2 of 22.04.2024
192 Workplace environment − air samples collected on sorbent tubes, General environment - waste gas samples collected on sorbent tubes Ethylene glycol content
Range (0,02 - 2,0) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PB-43 issue 3 of 22.04.2024
193 Workplace environment − air samples collected on sorbent tubes, General environment - waste gas samples collected on sorbent tubes Content of organic compounds
Hexane (0,002 - 0,31) mg in the sample Acetone (0,002 - 0,77) mg in the sample Ethyl acetate (0,002 - 0,39) mg in the sample n-butyl acetate (0,002 - 0,36) mg in the sample Toluene (0,002 - 0,36) mg in the sample Xylene - mixture of isomers: 1,2-; 1,3-; 1,4- (0,002 - 0,36) mg in the sample Ethanol (0,003 - 0,64) mg in the sample Butan-2-one (0,002 - 0,39) mg in the sample 4-methylpentan-2-one (0,002 - 0,39) mg in the sample Dichloromethane (0,002 - 0,30) mg in the sample Trichloroethene (0,002 - 0,31) mg in the sample Tetrachloroethene (0,002 - 0,32) mg in the sample Propan-2-ol (0,002 - 0,63) mg in the sample Butan-2-ol (0,002 - 0,36) mg in the sample Propan-1-ol (0,002 - 0,39) mg in the sample 2-Methylpropan-1-ol (0,002 - 0,39) mg in the sample Butan-1-ol (0,002 - 0,20) mg in the sample Ethylbenzene (0,002 - 0,37) mg in the sample Cumene (0,002 - 0,36) mg in the sample 1,3,5- trimethylbenzene (0,002 - 0,38) mg in the sample 1,2,4- trimethylbenzene (0,002 - 0,36) mg in the sample 1,2,3- trimethylbenzene (0,002 - 0,38) mg in the sample 1-Methoxypropan-2-ol (0,004 - 0,39) mg in the sample 2-Methoxy-1-methylethyl acetate (0,003 - 0,40) mg in the sample Cyclohexanone (0,003 - 0,23) mg in the sample 2-butoxyethanol (0,003 - 0,38) mg in the sample 2-butoxyethyl acetate (0,003 - 0,40) mg in the sample Styrene (0,001 - 0,19) mg in the sample Extraction naphtha (0,002 - 0,57) mg in the sample Benzene (0,001 - 0,02) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PB-23 issue 3 of 22.04.2024

Reference standards (117)

ISO 12039:2019
ISO 15713:2006
PB- 08 issue 3 of 03.01.2011
PB-01 issue 4 of 15.01.2014
PB-04 issue 1 of 01.09.2020
PB-07 issue 2 of 09.01.2009
PB-09 issue 1 of 07.04.2026
PB-10 issue 3 of 03.01.2011
PB-11 issue 2 of 09.01.2009
PB-13 issue 5 of 22.04.2024
PB-14 issue 5 of 22.04.2024
PB-15 issue 5 of 29.08.2023
PB-16 issue 5 of 22.04.2024
PB-17 issue 5 of 22.04.2024
PB-18 issue 3 of 22.04.2024
PB-19 issue 5 of 22.04.2024
PB-22 issue 4 of 04.02.2020
PB-23 issue 3 of 22.04.2024
PB-24 issue 2 of 03.01.2011
PB-26 issue 2 of 03.01.2011
PB-27 issue 1 of 07.01.2010
PB-28 issue 1 of 07.01.2010
PB-29 issue 2 of 22.04.2024
PB-31 issue 2 of 22.04.2024
PB-32 issue 2 of 22.04.2024
PB-33 issue 2 of 22.04.2024
PB-34 issue 1 of 10.05.2010
PB-35 issue 1 of 10.05.2010
PB-36 issue 2 of 22.04.2024
PB-41 issue 3 of 09.01.2012
PB-42 issue 2 of 22.04.2024
PB-43 issue 3 of 22.04.2024
PB-45 issue 1 of 15.12.2016 based on the Merck cuvette test 1.14540
PB-47 issue 4 of 27.07.2026
PN-C-04541:1978
PN-C-04584:1977
PN-EN 1233:2000
PN-EN 12619:2013
PN-EN 13211:2006
PN-EN 13284-1:2018-02
PN-EN 13649:2005
PN-EN 13649:2005 *
PN-EN 14253+A1:2011
PN-EN 14385:2025-05
PN-EN 14789:2017-4
PN-EN 14790:2017-04
PN-EN 14791:2017-04
PN-EN 14792:2017-4
PN-EN 15058:2017-4
PN-EN 1838:2025-05 excluding cl. 5.1.3, 5.1.4, 5.1.7, 5.1.8, 5.2.3, 5.2.4, 5.2.7, 5.3.4, 5.3.5, 5.3.7, 5.3.8, 6, 7
PN-EN 1911:2011
PN-EN 1948-1:2006
PN-EN 27888:1999
PN-EN 458:2016-06
PN-EN 872:2007 + Ap1:2007
PN-EN ISO 10523:2012
PN-EN ISO 11079:2008
PN-EN ISO 16911-1:2013
PN-EN ISO 19458:2007
PN-EN ISO 21877:2020-03
PN-EN ISO 23210:2010
PN-EN ISO 4869-2:2018-2
PN-EN ISO 5349-1:2004
PN-EN ISO 5349-2:2004
PN-EN ISO 5349-2:2004/A1:2015-11
PN-EN ISO 5667-6:2016-12 excluding cl. 7.4, 7.5, 7.6
PN-EN ISO 5815-1:2019-12
PN-EN ISO 7243:2018-01 +Ap2:2020-04P
PN-EN ISO 7730:2006+Ap2:2016-04
PN-EN ISO 9612:2025-11
PN-EN ISO 9612:2025-11 excluding the method covering strategy 2 - cl. 10 and strategy 3 - cl. 11
PN-ISO 10396:2001
PN-ISO 5667-10:2021-11
PN-ISO 5667-5:2017-10
PN-ISO 6060:2006
PN-ISO 8288:2002; Method A
PN-ISO 8518:1994
PN-N-01307:1994
PN-Z 04502:2019-10
PN-Z-04007-2:1994
PN-Z-04008-4:1999
PN-Z-04008-4:1999 *
PN-Z-04008-7:2002+Az1:2004
PN-Z-04009-11:2008
PN-Z-04017-03:1990 excluding cl. 8
PN-Z-04030-7:1994
PN-Z-04037-03:1975
PN-Z-04041:1971
PN-Z-04045-02:1976
PN-Z-04045-06:1982
PN-Z-04100-03:1987
PN-Z-04102-3:2013
PN-Z-04106-3:2002
PN-Z-04134-02:1981
PN-Z-04152-02:1986
PN-Z-04178-02:1987
PN-Z-04178-02:1987 excluding cl. 8
PN-Z-04227-02:1992
PN-Z-04227-02:1992 excluding cl. 8
PN-Z-04263-1:2012
PN-Z-04318:2005
PN-Z-04318:2005 excluding cl. 8
PN-Z-04333:2006
PN-Z-04434:2011
PN-Z-04442-10:2023-05
PN-Z-04469:2025-02
PN-Z-04472:2015-10
PN-Z-04488:2017-10
PN-Z-04507:2022-05
PN-Z-04507:2022-05/Ap1:2022-08
PN-Z-04508:2022-05
PN-Z-04508:2022-05/Ap1:2022-08
PiMOŚP 2012 No. 4 (74) pp. 117-130
Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023 item 1706) - excluding cl. F
based on Merck test 1.14537 and 1.14763
based on Merck test 1.14551
based on Nanocolor test 1-48

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/PL/AB%20940