🇵🇱 „EKO-LAB” Sp. z o.o. PL
EnvironmentWater & wastewaterMaterials & polymers
„EKO-LAB” Sp. z o.o. is a laboratory accredited by PCA under number AB 940 (Wałbrzych, Poland). Its accreditation scope covers 193 test methods in the following areas: Environment, Water & wastewater, Materials & polymers. Test objects include: Waste gases, Workplace environment − air, Waste gases - waste gas samples collected on a filter and into abso…, Water, wastewater. Most frequently used techniques: Flame atomic absorption spectrometry (FAAS), Gas chromatography with flame ionization detection (GC-FID), Spectrophotometric method.
At a glance
- Accreditation number: PCA AB 940
- Methods in scope: 193
- Types of test objects: 20
- Techniques used: 27
- City: Wałbrzych, Poland
- Accreditation number
- AB 940
- Accreditation body
- PCA
- Address
- ul. Beethovena 1, 58-300 Wałbrzych
- City
- Wałbrzych, Poland
What this laboratory tests (20)
- Waste gases — 64 methods
- Workplace environment − air — 38 methods
- Waste gases - waste gas samples collected on a filter and into absorbing solution — 21 methods
- Water, wastewater — 19 methods
- Workplace environment − air samples collected on sorbent tubes, General environment - waste gas samples collected on sorbent tubes — 8 methods
- Workplace environment − noise — 6 methods
- Workplace environment – emergency lighting — 4 methods
- Workplace environment − noise (selection of hearing protectors) — 4 methods
- Wastewater — 3 methods
- Water intended for consumption — 3 methods
- Working environment - electromagnetic field from industrial installations and equipment: - arc welding equipment - resistance welders - induction heating equipment - electric vehicles - soldering equipment - electrical discharge machines - resistance and arc furnaces - generators and electric motors - inverters — 3 methods
- Workplace environment − hand-arm vibration — 3 methods
- Workplace environment − whole-body vibration — 3 methods
- General environment − noise from installations, or equipment and industrial plants — 2 methods
- Process waters — 2 methods
- and 5 more
Analytical techniques used (27)
- Flame atomic absorption spectrometry (FAAS) — 34 methods
- Gas chromatography with flame ionization detection (GC-FID) — 29 methods
- Spectrophotometric method — 16 methods
- Direct measurement method — 14 methods
- Gravimetric method — 7 methods
- Electrochemical method — 4 methods
- Non-dispersive infrared spectrometry NDIR — 3 methods
- Anemometric method — 2 methods
- Chemiluminescence method — 2 methods
- Potentiometric method — 2 methods
- Aspiration method using absorption tubes — 1 method
- Aspiration method using activated carbon / silica gel / absorbing solutions — 1 method
- Cold vapour atomic absorption spectrometry (CVAAS) — 1 method
- Condensation-adsorption method; Temperature method — 1 method
- Conductometric method — 1 method
- and 12 more
Laboratory locations
- „EKO-LAB” Sp. z o.o. (main site) — ul. Beethovena 1, 58-300 Wałbrzych
- Chromatography Laboratory; "Jedlina Branch" — ul. Warszawska 12A, 58-330 Jedlina Zdrój
Certificate information
- Issue date
- 17.09.2026
- Issue no.
- 21
Accreditation scope — test methods (193)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Workplace environment − air | Sampling for assessment of occupational exposure to: − dust agents inhalable fraction respirable fraction − organic substances, including inhalable fraction − inorganic substances, including inhalable fraction respirable fraction thoracic fraction − metals and their compounds, including inhalable fraction respirable fraction asbestos − respirable fibres man-made mineral fibres except refractory ceramic fibres − respirable fibres fibrous silicon carbide − respirable fibres |
Personal dosimetry method | PN-Z-04008-7:2002+Az1:2004 | |
| 2 | Workplace environment − air | Sampling for occupational exposure assessment to: − organic substances − inorganic substances | Personal dosimetry method; Stationary method | PN-Z-04008-7:2002+Az1:2004 | |
| 3 | Workplace environment − air | Exposure index (calculated) | PN-Z-04008-7:2002+Az1:2004 | ||
| 4 | Workplace environment − air | Concentration/content of the respirable fraction crystalline silica (quartz, cristobalite) Range (0,007 - 0,5) mg/m3 Range (0,007 - 0,40) mg in the sample |
Fourier transform infrared spectrometry method FT-IR | PiMOŚP 2012 No. 4 (74) pp. 117-130 | |
| 5 | Workplace environment − air | Concentration of nitrogen monoxide and nitrogen dioxide NO (0,14 - 17,77) mg/m3 Range (0,112 - 14,28) ppm NO2 (0,04 - 3,55) mg/m3 Range (0,021 - 1,860) ppm |
Spectrophotometric method | PN-Z-04009-11:2008 | |
| 6 | Workplace environment − air | Carbon monoxide concentration Range (2,3 - 232) mg/m3 Range (2 - 200) ppm |
Electrochemical method | PB-01 issue 4 of 15.01.2014 | |
| 7 | Workplace environment − air | Exposure indices (calculated) | PB-01 issue 4 of 15.01.2014 | ||
| 8 | Workplace environment − air | Ammonia concentration/content Range (0,23 - 46) mg/m3 Range (0,002 - 6,0) mg in the sample |
Spectrophotometric method | PN-Z-04041:1971 | PB-10 issue 3 of 03.01.2011 | |
| 9 | Workplace environment − air | Chlorine concentration/content Range (0,07 - 5,0) mg/m3 |
Spectrophotometric method | PN-Z-04037-03:1975 | |
| 10 | Workplace environment − air | Concentration of dust agents harmful to health – inhalable fraction: Apatites and phosphorites Petroleum bitumen Portland cement Titanium dioxide Natural graphite Synthetic graphite Kaolin Amorphous and synthetic silica Wood dusts Flour dusts Dusts not classified according to toxicity Organic dusts of animal and plant origin, except wood and flour dusts Calcium sulfate (VI) (gypsum) Carbon black Man-made mineral fibres except refractory ceramic fibres Talc Coal (hard, brown) Calcium magnesium carbonate (dolomite) Silicon carbide, non-fibrous Fibrous silicon carbide Range (0,13 - 50) mg/m3 |
Gravimetric method | PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08 | |
| 11 | Workplace environment − air | Concentration of dust agents harmful to health – respirable fraction: Apatites and phosphorites Portland cement Natural graphite Amorphous and synthetic silica Organic dusts of animal and plant origin, except wood and flour dusts Talc Coal (hard, brown) Range (0,09 - 7,3) mg/m3 |
Gravimetric method | PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08 | |
| 12 | Workplace environment − air | Formaldehyde concentration/content Range (0,025 - 5,5) mg/m3 Range (0,0003 - 0,8) mg in the sample |
Spectrophotometric method | PN-Z-04045-02:1976 | PB-24 issue 2 of 03.01.2011 | |
| 13 | Workplace environment − air | Ozone concentration Range (0,025 - 0,25) mg/ m3 |
Spectrophotometric method | PN-Z-04007-2:1994 | |
| 14 | Workplace environment − air | Concentration/content of iron oxides calculated as Fe – respirable fraction – inhalable fraction Range (0,06 - 15,0) mg/m3 Range (0,015 - 6,0) mg in the sample |
Flame atomic absorption spectrometry (FAAS) | PN-Z-04469:2025-02 | |
| 15 | Workplace environment − air | Concentration/content of manganese and its inorganic compounds – expressed as Mn inhalable fraction respirable fraction Range (0,002 - 12,0) mg/m3 Range (0,002 - 4,8) mg in the sample |
Flame atomic absorption spectrometry (FAAS) | PN-Z-04472:2015-10 | |
| 16 | Workplace environment − air | Concentration/content of nickel and its compounds except nickel tetracarbonyl – calculated as Ni Range (0,001 - 2,78) mg/m3 Range (0,001 - 2,0) mg in the sample |
Flame atomic absorption spectrometry (FAAS) | PN-Z 04502:2019-10 | |
| 17 | Workplace environment − air | Concentration/content of metallic chromium, chromium compounds: chromium (II), chromium (III), chromium (VI) – calculated as Cr. Range (0,001 - 2,3) mg/m3 Range (0,004 - 0,92) mg in the sample |
Flame atomic absorption spectrometry (FAAS) | PN-Z-04434:2011 | |
| 18 | Workplace environment − air | Concentration/content of copper and its inorganic compounds – calculated as Cu Range (0,005 - 2,4) mg/m3 Range (0,0002 - 0,6) mg in the sample |
Flame atomic absorption spectrometry (FAAS) | PN-Z-04106-3:2002 | |
| 19 | Workplace environment − air | Concentration/content of zinc oxide - calculated as Zn – inhalable fraction Range (0,04 - 8,0) mg/m3 Range (0,004 - 0,8) mg in the sample |
Flame atomic absorption spectrometry (FAAS) | PN-Z-04100-03:1987 | |
| 20 | Workplace environment − air | Concentration/content of lead and its inorganic compounds excluding lead (II) arsenate (V) and lead (II) chromate (VI) calculated as Pb – inhalable fraction Range (0,001 - 0,4) mg/m3 Range (0,004 - 0,2) mg in the sample |
Flame atomic absorption spectrometry (FAAS) | PN-ISO 8518:1994 | |
| 21 | Workplace environment − air | Aluminium trioxide concentration/content – calculated as Al: inhalable fraction respirable fraction Range (0,006 - 2,22) mg/m3 Range (0,004 - 1,6) mg in the sample metallic aluminium, aluminium powder (non-stabilised): inhalable fraction respirable fraction Range (0,006 - 2,22) mg/m3 Range (0,004 - 1,6) mg in the sample aluminium hydroxide – calculated as Al: inhalable fraction respirable fraction Range (0,006 - 2,22) mg/m3 Range (0,004 - 1,6) mg in the sample |
Flame atomic absorption spectrometry (FAAS) | PN-Z-04263-1:2012 | |
| 22 | Workplace environment − air | Concentration/content of tin and its inorganic compounds except stannane – calculated as Sn – inhalable fraction Range (0,06 - 12,0) mg/m3 Range (0,02 - 3,0) mg in the sample |
Flame atomic absorption spectrometry (FAAS) | PN-Z-04488:2017-10 | |
| 23 | Workplace environment − air | Concentration/content of cadmium and its inorganic compounds – calculated as Cd: inhalable fraction respirable fraction Range (0,001 - 2,5) mg/m3 Range (0,0001 - 0,5) mg in the sample |
Flame atomic absorption spectrometry (FAAS) | PN-Z-04102-3:2013 | |
| 24 | Workplace environment − air | Concentration/content calcium oxide inhalable fraction respirable fraction Range (0,01 - 8,74) mg/m3 Range (0,002 - 1,75) mg in the sample calcium carbonate (calculated) inhalable fraction Range (0,02 - 15,60) mg/m3 Range (0,003 - 3,12) mg in the sample calcium hydroxide (calculated) inhalable fraction respirable fraction Range (0,013 - 11,55) mg/m3 Range (0,003 - 2,31) mg in the sample |
Flame atomic absorption spectrometry (FAAS) | PN-Z-04442-10:2023-05 | |
| 25 | Workplace environment − moderate microclimate | Air temperature Range (-10) °C - (+30) °C Black globe temperature Range (-10) °C - (+40) °C Air humidity Range (25 - 75) % Air velocity Range (0,15 - 5) m/s |
Direct measurement method | PN-EN ISO 7730:2006+Ap2:2016-04 | |
| 26 | Workplace environment − moderate microclimate | PMV index, PPD index (calculated) | PN-EN ISO 7730:2006+Ap2:2016-04 | ||
| 27 | Workplace environment − hot microclimate | Air temperature Range (20 - 40) °C Natural wet bulb temperature Range (10 - 40) °C Black globe temperature Range (20 - 40) °C |
Direct measurement method | PN-EN ISO 7243:2018-01 +Ap2:2020-04P | |
| 28 | Workplace environment − hot microclimate | WBGT index, WBGTeff index (calculated) | PN-EN ISO 7243:2018-01 +Ap2:2020-04P | ||
| 29 | Workplace environment − cold microclimate | Air temperature Range (-20) °C - (+10) °C Black globe temperature Range (-20) °C - (+10) °C Air humidity Range (20 - 80) % Air velocity Range (0,15 - 5,0) m/s |
Direct measurement method | PN-EN ISO 11079:2008 | |
| 30 | Workplace environment − cold microclimate | IREQmin index, IREQneutral index, twc index (calculated) | PN-EN ISO 11079:2008 | ||
| 31 | Workplace environment − indoor electric lighting | Electric lighting illuminance Range (5 - 9 000) lx |
Direct measurement method | PB-22 issue 4 of 04.02.2020 | |
| 32 | Workplace environment − indoor electric lighting | Uniformity of electric lighting (calculated) | PB-22 issue 4 of 04.02.2020 | ||
| 33 | Workplace environment − hand-arm vibration | Root-mean-square, frequency-weighted vibration acceleration Range (0,5 - 100) m/s² |
Direct measurement method | PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11 | |
| 34 | Workplace environment − hand-arm vibration | Daily exposure expressed as the 8-hour energy-equivalent vector sum of the effective frequency-weighted vibration accelerations determined for the three directional components (ahwx, ahwy, ahwz) | PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11 | ||
| 35 | Workplace environment − hand-arm vibration | Exposure lasting 30 min or less, expressed as the vector sum of the effective frequency-weighted vibration accelerations determined for the three directional components (ahwx, ahwy, ahwz) (calculated) | PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11 | ||
| 36 | Workplace environment − whole-body vibration | Root-mean-square, frequency-weighted vibration acceleration Range (0,07 - 35,5) m/s² |
Direct measurement method | PN-EN 14253+A1:2011 | |
| 37 | Workplace environment − whole-body vibration | Daily exposure expressed as the 8-hour energy-equivalent effective frequency-weighted vibration acceleration, dominant among the vibration accelerations determined for the three directional components, taking into account the appropriate coefficients (1.4awx, 1.4awy, awz) | PN-EN 14253+A1:2011 | ||
| 38 | Workplace environment − whole-body vibration | Exposure lasting 30 min or less, expressed as the effective frequency-weighted vibration acceleration, dominant among the vibration accelerations determined for the three directional components, taking into account the appropriate coefficients (1.4awx, 1.4awy, awz) (calculated) | PN-EN 14253+A1:2011 | ||
| 39 | Workplace environment − noise | A-weighted equivalent sound pressure level | PN-N-01307:1994 | PN-EN ISO 9612:2025-11 excluding the method covering strategy 2 - cl. 10 and strategy 3 - cl. 11 | ||
| 40 | Workplace environment − noise | Maximum A-weighted sound pressure level Range (25 - 135) dB |
PN-N-01307:1994 | PN-EN ISO 9612:2025-11 excluding the method covering strategy 2 - cl. 10 and strategy 3 - cl. 11 | ||
| 41 | Workplace environment − noise | C-weighted peak sound pressure level Range (50 - 138) dB |
Direct measurement method | PN-N-01307:1994 | PN-EN ISO 9612:2025-11 excluding the method covering strategy 2 - cl. 10 and strategy 3 - cl. 11 | |
| 42 | Workplace environment − noise | Noise exposure level referred to: | PN-N-01307:1994 | PN-EN ISO 9612:2025-11 excluding the method covering strategy 2 - cl. 10 and strategy 3 - cl. 11 | ||
| 43 | Workplace environment − noise | − for an 8-h daily working time | PN-N-01307:1994 | PN-EN ISO 9612:2025-11 excluding the method covering strategy 2 - cl. 10 and strategy 3 - cl. 11 | ||
| 44 | Workplace environment − noise | − the average weekly working time (calculated) | PN-N-01307:1994 | PN-EN ISO 9612:2025-11 excluding the method covering strategy 2 - cl. 10 and strategy 3 - cl. 11 | ||
| 45 | Workplace environment − noise (selection of hearing protectors) | Equivalent sound pressure level in octave frequency bands Range (63 - 8000) Hz Range (50 - 135) dB |
PN-EN ISO 9612:2025-11 | PN-EN 458:2016-06 | PN-EN ISO 4869-2:2018-2 | ||
| 46 | Workplace environment − noise (selection of hearing protectors) | A-weighted equivalent sound pressure level | PN-EN ISO 9612:2025-11 | PN-EN 458:2016-06 | PN-EN ISO 4869-2:2018-2 | ||
| 47 | Workplace environment − noise (selection of hearing protectors) | Equivalent C-weighted sound level Range (50 - 138) dB |
Direct measurement method | PN-EN ISO 9612:2025-11 | PN-EN 458:2016-06 | PN-EN ISO 4869-2:2018-2 | |
| 48 | Workplace environment − noise (selection of hearing protectors) | A-weighted equivalent sound level under hearing protectors (calculated) | PN-EN ISO 9612:2025-11 | PN-EN 458:2016-06 | PN-EN ISO 4869-2:2018-2 | ||
| 49 | General environment − noise from installations, or equipment and industrial plants | A-weighted equivalent sound pressure level Range (25 - 130) dB |
Direct measurement method | Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023 item 1706) - excluding cl. F | |
| 50 | General environment − noise from installations, or equipment and industrial plants | A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) | Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023 item 1706) - excluding cl. F | ||
| 51 | Workplace environment – emergency lighting | Electric lighting illuminance Range (0,5 - 500) lx |
Direct measurement method | PN-EN 1838:2025-05 excluding cl. 5.1.3, 5.1.4, 5.1.7, 5.1.8, 5.2.3, 5.2.4, 5.2.7, 5.3.4, 5.3.5, 5.3.7, 5.3.8, 6, 7 | |
| 52 | Workplace environment – emergency lighting | Ratio of minimum to maximum illuminance Ud (calculated) | PN-EN 1838:2025-05 excluding cl. 5.1.3, 5.1.4, 5.1.7, 5.1.8, 5.2.3, 5.2.4, 5.2.7, 5.3.4, 5.3.5, 5.3.7, 5.3.8, 6, 7 | ||
| 53 | Workplace environment – emergency lighting | Closing time Range (0,5 - 80) s |
Direct measurement method | PN-EN 1838:2025-05 excluding cl. 5.1.3, 5.1.4, 5.1.7, 5.1.8, 5.2.3, 5.2.4, 5.2.7, 5.3.4, 5.3.5, 5.3.7, 5.3.8, 6, 7 | |
| 54 | Workplace environment – emergency lighting | Operation time Range (1 - 60) min |
Direct measurement method | PN-EN 1838:2025-05 excluding cl. 5.1.3, 5.1.4, 5.1.7, 5.1.8, 5.2.3, 5.2.4, 5.2.7, 5.3.4, 5.3.5, 5.3.7, 5.3.8, 6, 7 | |
| 55 | Working environment - electromagnetic field from industrial installations and equipment: - arc welding equipment - resistance welders - induction heating equipment - electric vehicles - soldering equipment - electrical discharge machines - resistance and arc furnaces - generators and electric motors - inverters | Electric field strength: in the frequency range from 10 Hz to 400 kHz Range (1 – 50000) V/m |
Direct measurement method | PB-09 issue 1 of 07.04.2026 | |
| 56 | Working environment - electromagnetic field from industrial installations and equipment: - arc welding equipment - resistance welders - induction heating equipment - electric vehicles - soldering equipment - electrical discharge machines - resistance and arc furnaces - generators and electric motors - inverters | Magnetic flux density: in the frequency range from 10 Hz to 400 kHz Range (1 – 19000) μT |
Direct measurement method | PB-09 issue 1 of 07.04.2026 | |
| 57 | Working environment - electromagnetic field from industrial installations and equipment: - arc welding equipment - resistance welders - induction heating equipment - electric vehicles - soldering equipment - electrical discharge machines - resistance and arc furnaces - generators and electric motors - inverters | Magnetic field strength (calculated) in the frequency range from 10 Hz to 400 kHz |
PB-09 issue 1 of 07.04.2026 | ||
| 58 | Waste gases | Gas volume flow rate for dynamic pressures > 5 Pa Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Stagnation pressure method | PN-Z-04030-7:1994 | |
| 59 | Waste gases | Velocity Range (1,0 - 6,0) m/s Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Anemometric method | PN-Z-04030-7:1994 | |
| 60 | Waste gases | Sampling for determination of dust concentration Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
PN-Z-04030-7:1994 | ||
| 61 | Waste gases | Dust concentration Range (0,0005 - 9,5) g/m3 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Gravimetric method | PN-Z-04030-7:1994 | |
| 62 | Waste gases | Dust emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
PN-Z-04030-7:1994 | ||
| 63 | Waste gases | Sampling for determination of dust concentration Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
PN-EN 13284-1:2018-02 | ||
| 64 | Waste gases | Dust concentration Range (0,0002 - 0,1) g/m3 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Gravimetric method | PN-EN 13284-1:2018-02 | |
| 65 | Waste gases | Dust emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
PN-EN 13284-1:2018-02 | ||
| 66 | Waste gases | Sulphur dioxide concentration Range (3 - 1700) mg/m3 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Non-dispersive infrared spectrometry NDIR | PN-ISO 10396:2001 | |
| 67 | Waste gases | SO2 emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
PN-ISO 10396:2001 | ||
| 68 | Waste gases | Carbon monoxide concentration Range (1 - 5300) mg/m3 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Non-dispersive infrared spectrometry NDIR | PN-ISO 10396:2001 | PN-EN 15058:2017-4 | |
| 69 | Waste gases | CO emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
PN-ISO 10396:2001 | PN-EN 15058:2017-4 | ||
| 70 | Waste gases | Carbon dioxide concentration Range (0,1 - 20,0) % Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Non-dispersive infrared spectrometry NDIR | PN-ISO 10396:2001 | ISO 12039:2019 | |
| 71 | Waste gases | CO2 emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
PN-ISO 10396:2001 | ISO 12039:2019 | ||
| 72 | Waste gases | Nitrogen oxide concentration Range (1 - 600) mg/m3 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Chemiluminescence method | PN-ISO 10396:2001 | PN-EN 14792:2017-4 | |
| 73 | Waste gases | Nitrogen oxides concentration Range (2 - 900) mg/m3 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Chemiluminescence method | PN-ISO 10396:2001 | PN-EN 14792:2017-4 | |
| 74 | Waste gases | Emission of NO and NOx (NO and NO2 calculated as NO2) (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
PN-ISO 10396:2001 | PN-EN 14792:2017-4 | ||
| 75 | Waste gases | Oxygen concentration Range (1,0 - 21,0) % Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Paramagnetic method | PN-ISO 10396:2001 | PN-EN 14789:2017-4 | |
| 76 | Waste gases | Oxygen concentration Range (1,0 - 21,0) % Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Electrochemical method | PN-ISO 10396:2001 | |
| 77 | Waste gases | Sampling for determination of hydrogen chloride concentration Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
PN-EN 1911:2011 | ||
| 78 | Waste gases | Hydrogen chloride concentration/content Range (0,95 - 166) mg/m3 Range (0,057 - 10) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Spectrophotometric method | PN-EN 1911:2011 | |
| 79 | Waste gases | Hydrogen chloride emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
PN-EN 1911:2011 | ||
| 80 | Waste gases | Sampling for determination of hydrogen fluoride concentration Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
ISO 15713:2006 | ||
| 81 | Waste gases | Hydrogen fluoride concentration Range (0,1 - 190) mg/m3 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Potentiometric method | ISO 15713:2006 | |
| 82 | Waste gases | Hydrogen fluoride emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
ISO 15713:2006 | ||
| 83 | Waste gases | Sampling for determination of the concentration of individual gaseous organic compounds. Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Aspiration method using absorption tubes | PN-EN 13649:2005 | |
| 84 | Waste gases | Emission of individual gaseous organic compounds (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
PN-EN 13649:2005 | ||
| 85 | Waste gases | Sampling for determination of the concentrations of organic compounds. Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Aspiration method using activated carbon / silica gel / absorbing solutions | PN-Z-04008-4:1999 | |
| 86 | Waste gases | Emission of organic compounds (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
PN-Z-04008-4:1999 | ||
| 87 | Waste gases | Concentration of organic substances in the form of gases and vapours expressed as total gaseous organic carbon Range (1,0 - 1000) mg/m3 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Continuous flame ionization detection method (FID) | PN-EN 12619:2013 | |
| 88 | Waste gases | Emission of organic substances in gaseous and vapour form expressed as total gaseous organic carbon (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
PN-EN 12619:2013 | ||
| 89 | Waste gases | Sampling for determination of sulfur dioxide concentration SO2 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
PN-EN 14791:2017-04 | ||
| 90 | Waste gases | Concentration/content of sulphur dioxide SO2 Range (1,11 - 2320) mg/m3 Range (0,1 - 209) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Thoron method | PN-EN 14791:2017-04 | |
| 91 | Waste gases | Emission of sulphur dioxide SO2 (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
PN-EN 14791:2017-04 | ||
| 92 | Waste gases | Water vapour concentration (H2O) Range (23 - 250 g/m3 Range (3,0 - 40,0) % Range (3,0 - 57,0) % Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Condensation-adsorption method; Temperature method | PN-EN 14790:2017-04 | |
| 93 | Waste gases - waste gas samples collected on a filter and into absorbing solution | Sampling for determination of metal concentrations: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
PN-EN 14385:2025-05 | ||
| 94 | Waste gases - waste gas samples collected on a filter and into absorbing solution | Concentration/content of manganese Range (0,0003 - 48,0) mg/m3 Range (0,001 - 24,0) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Flame atomic absorption spectrometry (FAAS) | PN-EN 14385:2025-05 | |
| 95 | Waste gases - waste gas samples collected on a filter and into absorbing solution | Concentration/content of nickel Range (0,002 - 20,0) mg/m3 Range (0,004 - 10,0) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Flame atomic absorption spectrometry (FAAS) | PN-EN 14385:2025-05 | |
| 96 | Waste gases - waste gas samples collected on a filter and into absorbing solution | Concentration/content of copper Range (0,0001 - 6,0) mg/m3 Range (0,0002 - 3,0) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Flame atomic absorption spectrometry (FAAS) | PN-EN 14385:2025-05 | |
| 97 | Waste gases - waste gas samples collected on a filter and into absorbing solution | Concentration/content of lead Range (0,0004 - 4,0) mg/m3 Range (0,001 - 2,0) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Flame atomic absorption spectrometry (FAAS) | PN-EN 14385:2025-05 | |
| 98 | Waste gases - waste gas samples collected on a filter and into absorbing solution | Concentration/content of cobalt Range (0,0004 - 5,0) mg/m3 Range (0,002 - 2,5) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Flame atomic absorption spectrometry (FAAS) | PN-EN 14385:2025-05 | |
| 99 | Waste gases - waste gas samples collected on a filter and into absorbing solution | Concentration/content of cadmium Range (0,0001 - 0,7) mg/m3 Range (0,0002 - 2,5) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Flame atomic absorption spectrometry (FAAS) | PN-EN 14385:2025-05 | |
| 100 | Waste gases - waste gas samples collected on a filter and into absorbing solution | Concentration/content of chromium Range (0,0005 - 18,4) mg/m3 Range (0,001 - 9,2) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Flame atomic absorption spectrometry (FAAS) | PN-EN 14385:2025-05 | |
| 101 | Waste gases - waste gas samples collected on a filter and into absorbing solution | Emission of metals: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
PN-EN 14385:2025-05 | ||
| 102 | Waste gases - waste gas samples collected on a filter and into absorbing solution | Sampling for determination of total mercury concentration Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
PN-EN 13211:2006 | ||
| 103 | Waste gases - waste gas samples collected on a filter and into absorbing solution | Total mercury concentration Range (0,0033 - 770,0) µg/m3 Range (0,007 - 87,5) µg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Cold vapour atomic absorption spectrometry (CVAAS) | PN-EN 13211:2006 | |
| 104 | Waste gases - waste gas samples collected on a filter and into absorbing solution | Total mercury concentration (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
PN-EN 13211:2006 | ||
| 105 | Waste gases | Sampling of PM10; PM2,5 dust for testing | PN-EN ISO 23210:2010 | ||
| 106 | Waste gases | PM10; PM2,5 dust concentration Range (0,0005 ÷ 0,04) g/m3 |
Gravimetric method | PN-EN ISO 23210:2010 | |
| 107 | Waste gases | Emission of dust PM10/PM2,5 (calculated) | PN-EN ISO 23210:2010 | ||
| 108 | Waste gases | Waste gas sampling for determination of formaldehyde, ammonia, MDI, TDI, ozone, sulfuric acid, chlorine | PB-47 issue 4 of 27.07.2026 | ||
| 109 | Waste gases | Formaldehyde concentration/content Range (0,07 - 100) mg/m3 Range (0,001 - 0,8) mg in the sample |
Spectrophotometric method | PB-24 issue 2 of 03.01.2011 | |
| 110 | Waste gases | Sulfuric(VI) acid concentration/content Range (0,1 - 200) mg/m3 Range (0,12 - 20,0) mg in the sample |
Turbidimetric method | PB-26 issue 2 of 03.01.2011 | |
| 111 | Waste gases | Ammonia concentration/content Range (0,23 - 230) mg/m3 Range (0,003 - 6,0) mg in the sample |
Spectrophotometric method | PB-10 issue 3 of 03.01.2011 | |
| 112 | Waste gases | Ozone concentration Range (0,025 - 0,25) mg/ m3 |
Spectrophotometric method | PB-34 issue 1 of 10.05.2010 | |
| 113 | Waste gases | Concentration/content of methylenebis(phenyl isocyanate) Range (0,014 - 3,33) mg/m3 Range (0,001 - 0,5) mg in the sample |
Spectrophotometric method | PB- 08 issue 3 of 03.01.2011 | |
| 114 | Waste gases | Emission of formaldehyde, ammonia, MDI, TDI, ozone, sulphuric acid. (calculated) | PB-47 issue 4 of 27.07.2026 | ||
| 115 | Waste gases | Sampling for determination of metals in PM10; PM2,5 dust | PN-EN ISO 23210:2010 | ||
| 116 | Waste gases | Emission of metals in dust PM10; PM2,5 (calculated) | PN-EN ISO 23210:2010 | ||
| 117 | Waste gases | Gas volume flow rate for dynamic pressures > 5 Pa | Differential pressure measurement method | PN-EN ISO 16911-1:2013 | |
| 118 | Waste gases | Velocity Range (1,0 - 6,0) m/s |
Anemometric method | PN-EN ISO 16911-1:2013 | |
| 119 | Waste gases | Chlorine concentration Cl Range (0,03 - 5,0) mg/m3 |
Spectrophotometric method | PB-04 issue 1 of 01.09.2020 | |
| 120 | Waste gases | Emission of chlorine Cl (calculated) | PB-04 issue 1 of 01.09.2020 | ||
| 121 | Waste gases | Sampling for determination of ammonia concentration NH3 | PN-EN ISO 21877:2020-03 | ||
| 122 | Waste gases | Ammonia NH3 concentration Range (0,08 - 32,0) mg/m3 |
Spectrophotometric method | PN-EN ISO 21877:2020-03 | |
| 123 | Waste gases | Ammonia NH3 emission (calculated) | PN-EN ISO 21877:2020-03 | ||
| 124 | Waste gases | Sampling for the determination of PCDD/PCDF mass concentration | PN-EN 1948-1:2006 | ||
| 125 | Waste gases | PCDD/PCDF emission (calculated) | PN-EN 1948-1:2006 | ||
| 126 | Waste gases - waste gas samples collected on a filter and into absorbing solution | Sampling for the determination of metals As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V, Fe, Zn, Al., Sn, Ca, Na, K | PN-EN 14385:2025-05 | ||
| 127 | Waste gases - waste gas samples collected on a filter and into absorbing solution | Iron concentration/content Range (0,0007 - 8,0) mg/m3 Range (0,002 - 40,0) mg in the sample |
Flame atomic absorption spectrometry (FAAS) | PN-EN 14385:2025-05 | |
| 128 | Waste gases - waste gas samples collected on a filter and into absorbing solution | Concentration/content of zinc Range (0,0005 - 16,0) mg/m3 Range (0,002 - 8,0) mg in the sample |
Flame atomic absorption spectrometry (FAAS) | PN-EN 14385:2025-05 | |
| 129 | Waste gases - waste gas samples collected on a filter and into absorbing solution | Aluminium concentration/content Range (0,006 - 32,0) mg/m3 Range (0,02 - 16,0) mg in the sample |
Flame atomic absorption spectrometry (FAAS) | PN-EN 14385:2025-05 | |
| 130 | Waste gases - waste gas samples collected on a filter and into absorbing solution | Concentration/content of tin Range (0,01 - 60,0) mg/m3 Range (0,03 - 30,0) mg in the sample |
Flame atomic absorption spectrometry (FAAS) | PN-EN 14385:2025-05 | |
| 131 | Waste gases - waste gas samples collected on a filter and into absorbing solution | Concentration/content of calcium Range (0,0002 - 9,98) mg/m3 Range (0,006 - 13,0) mg in the sample |
Flame atomic absorption spectrometry (FAAS) | PN-EN 14385:2025-05 | |
| 132 | Waste gases - waste gas samples collected on a filter and into absorbing solution | Concentration/content of sodium Range (0,001 - 14,0) mg/m3 Range (0,005 - 0,42) mg in the sample |
Flame atomic absorption spectrometry (FAAS) | PN-EN 14385:2025-05 | |
| 133 | Waste gases - waste gas samples collected on a filter and into absorbing solution | Concentration/content of potassium Range (0,0002 - 30,6) mg/m3 Range (0,001 - 0,92) mg in the sample |
Flame atomic absorption spectrometry (FAAS) | PN-EN 14385:2025-05 | |
| 134 | Waste gases - waste gas samples collected on a filter and into absorbing solution | Emission of metals As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V, Fe, Zn, Al, Sn, Ca, Na, K (calculated) | PN-EN 14385:2025-05 | ||
| 135 | Water, wastewater | pH Range 4,0 - 12,0 |
Potentiometric method | PN-EN ISO 10523:2012 | |
| 136 | Water, wastewater | Biochemical oxygen demand - BOD5 Range (3 - 6000) mg/l O2 |
Electrochemical method | PN-EN ISO 5815-1:2019-12 | |
| 137 | Water, wastewater | Chemical oxygen demand - COD Range (30 - 7000) mg/l O2 |
Titrimetric method | PN-ISO 6060:2006 | |
| 138 | Water, wastewater | Chemical oxygen demand - COD Range (10 - 1500) mg/l O2 |
Spectrophotometric method | PB-45 issue 1 of 15.12.2016 based on the Merck cuvette test 1.14540 | |
| 139 | Water, wastewater | Dry residue Range (5 - 3000) mg/l Dissolved solids Range (5 - 3000) mg/l |
Gravimetric method | PN-C-04541:1978 | |
| 140 | Water, wastewater | Total suspended solids (TSS) Range (2,0 - 1000) mg/l |
Gravimetric method | PN-EN 872:2007 + Ap1:2007 | |
| 141 | Water, wastewater | Silica concentration Range (0,005 - 4,0) mg/l |
Spectrophotometric method | PB-11 issue 2 of 09.01.2009 | based on Nanocolor test 1-48 | |
| 142 | Water, wastewater | Electrical conductivity Range (10 - 1999) μS/cm |
Conductometric method | PN-EN 27888:1999 | |
| 143 | Water, wastewater | Total nitrogen concentration Range (0,5 - 150) mg/l |
Spectrophotometric method | PB-27 issue 1 of 07.01.2010 | based on Merck test 1.14537 and 1.14763 | |
| 144 | Water, wastewater | Iron concentration Range (0,01 - 50,0) mg/l |
Flame atomic absorption spectrometry (FAAS) | PB-41 issue 3 of 09.01.2012 | |
| 145 | Water, wastewater | Manganese concentration Range (0,006 - 30,0) mg/l |
Flame atomic absorption spectrometry (FAAS) | PB-41 issue 3 of 09.01.2012 | |
| 146 | Water, wastewater | Lead concentration Range (0,04 - 50) mg/l |
Flame atomic absorption spectrometry (FAAS) | PN-ISO 8288:2002; Method A | |
| 147 | Water, wastewater | Nickel concentration Range (0,01 - 50) mg/l |
Flame atomic absorption spectrometry (FAAS) | PN-ISO 8288:2002; Method A | |
| 148 | Water, wastewater | Cobalt concentration Range (0,03 - 50) mg/l |
Flame atomic absorption spectrometry (FAAS) | PN-ISO 8288:2002; Method A | |
| 149 | Water, wastewater | Zinc concentration Range (0,05 - 10) mg/l |
Flame atomic absorption spectrometry (FAAS) | PN-ISO 8288:2002; Method A | |
| 150 | Water, wastewater | Copper concentration Range (0,005 - 30) mg/l |
Flame atomic absorption spectrometry (FAAS) | PN-ISO 8288:2002; Method A | |
| 151 | Water, wastewater | Cadmium concentration Range (0,004 - 50) mg/l |
Flame atomic absorption spectrometry (FAAS) | PN-ISO 8288:2002; Method A | |
| 152 | Water, wastewater | Chromium concentration Range (0,01 - 60) mg/l |
Flame atomic absorption spectrometry (FAAS) | PN-EN 1233:2000 | |
| 153 | Water, wastewater | Dissolved oxygen concentration Range (0,5 - 15,0) mg/l O2 |
Electrochemical method | PB-07 issue 2 of 09.01.2009 | |
| 154 | Wastewater | Sampling for physical and chemical testing | Manual and automatic method | PN-ISO 5667-10:2021-11 | |
| 155 | Wastewater | Temperature of wastewater and of the collected wastewater sample Range (0,0 - 50,0) ºC |
PN-C-04584:1977 | ||
| 156 | Wastewater | Phenol concentration Range (0,1 - 2,5) mg/l |
Spectrophotometric method | PB-28 issue 1 of 07.01.2010 | based on Merck test 1.14551 | |
| 157 | Surface waters | Sampling for physical and chemical testing | PN-EN ISO 5667-6:2016-12 excluding cl. 7.4, 7.5, 7.6 | ||
| 158 | Surface waters | Temperature of water and of the collected water sample Range (0,0 - 50,0) ºC |
PN-C-04584:1977 | ||
| 159 | Process waters | Sampling for physical and chemical testing | PB-35 issue 1 of 10.05.2010 | ||
| 160 | Process waters | Temperature of water and of the collected water sample Range (0,0 - 50,0) ºC |
PN-C-04584:1977 | ||
| 161 | Water intended for consumption | Sampling for physical, chemical testing | PN-ISO 5667-5:2017-10 | ||
| 162 | Water intended for consumption | Temperature of water and of the collected water sample Range (0,0 - 50,0) ºC |
PN-C-04584:1977 | ||
| 163 | Water intended for consumption | Sampling for microbiological testing | PN-EN ISO 19458:2007 | ||
| Chromatography Laboratory; "Jedlina Branch" | |||||
| 164 | Workplace environment − air | Concentration of organic compounds Hexane (6,5 - 260) mg/m3 Acetone (20,0 - 2540) mg/m3 Ethyl acetate (10,0 - 1560) mg/m3 Range (2,74 - 427,2) ppm n-butyl acetate (10,0 - 1056) mg/m3 Toluene (8,0 - 350) mg/m3 Xylene - mixture of isomers: 1,2-; 1,3-; 1,4- (8,0 - 340) mg/m3 Ethanol (50,0 - 2520) mg/m3 Butan-2-one (10,0 - 966) mg/m3 4-methylpentan-2-one (8,0 - 320) mg/m3 |
Gas chromatography with flame ionization detection (GC-FID) | PB-13 issue 5 of 22.04.2024 | |
| 165 | Workplace environment − air | Concentration of organic compounds Dichloromethane (6,2 - 550) mg/m3 Range (1,76 - 156,1) ppm Trichloroethene (6,4 - 290) mg/m3 Tetrachloroethene (6,8 - 320) mg/m3 Range (0,98 - 46,5) ppm |
Gas chromatography with flame ionization detection (GC-FID) | PB-14 issue 5 of 22.04.2024 | |
| 166 | Workplace environment − air | Concentration of organic compounds Propan-2-ol (50,0 - 1258) mg/m3 Butan-2-ol (10,0 - 648) mg/m3 Propan-1-ol (10,0 - 640) mg/m3 2-Methylpropan-1-ol (8,0 - 320) mg/m3 Butan-1-ol (4,0 - 160) mg/m3 |
Gas chromatography with flame ionization detection (GC-FID) | PB-15 issue 5 of 29.08.2023 | |
| 167 | Workplace environment − air | Concentration of organic compounds Ethylbenzene (10,0 - 696) mg/m3 Cumene (7,5 - 340) mg/m3 1,3,5- trimethylbenzene (8,0 - 340) mg/m3 1,2,4- trimethylbenzene (8,0 - 350) mg/m3 1,2,3- trimethylbenzene (8,0 - 350) mg/m3 |
Gas chromatography with flame ionization detection (GC-FID) | PB-16 issue 5 of 22.04.2024 | |
| 168 | Workplace environment − air | Concentration of organic compounds 1-methoxypropan-2-ol (10,0 - 550) mg/m3 2-Methoxy-1-methylethyl acetate (10,0 - 776) mg/m3 Cyclohexanone (3,0 - 190) mg/m3 2-butoxyethanol (7,7 - 360) mg/m3 2-butoxyethyl acetate (8,2 - 370) mg/m3 |
Gas chromatography with flame ionization detection (GC-FID) | PB-17 issue 5 of 22.04.2024 | |
| 169 | Workplace environment − air | Styrene concentration Range (4,0 - 180,0) mg/m3 |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04152-02:1986 | PB-19 issue 5 of 22.04.2024 | |
| 170 | Workplace environment − air | Extraction naphtha concentration Range (20,0 - 1222) mg/m3 Benzene concentration Range (0,05 - 15,0) mg/m3 Range (0,015 - 4,63) ppm |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04134-02:1981 | PB-18 issue 3 of 22.04.2024 | |
| 171 | Workplace environment − air | Vinyl acetate concentration Range ( 0,21 - 124,0 ) mg/m3 |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04178-02:1987 | |
| 172 | Workplace environment − air | Kerosene concentration Range (0,625 - 400,0 ) mg/m3 |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04227-02:1992 | |
| 173 | Workplace environment − air | Phenol concentration Range (0,625 - 20,0 ) mg/m3 |
Gas chromatography with flame ionization detection (GC-FID) | PB-29 issue 2 of 22.04.2024 | |
| 174 | Workplace environment − air | Pentane concentration Range (0,21 - 3060 ) mg/m3 |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04318:2005 | |
| 175 | Workplace environment − air | Acrylaldehyde concentration Range (0,004 - 20,0) mg/m3 Range (0,0017 - 8,61) ppm |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04045-06:1982 | |
| 176 | Workplace environment − air | Turpentine concentration Range (11 - 600) mg/m3 |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04333:2006 | |
| 177 | Workplace environment − air | Ethylene glycol concentration Range (0,5 - 150) mg/m3 |
Gas chromatography with flame ionization detection (GC-FID) | PB-43 issue 3 of 22.04.2024 | |
| 178 | Waste gases | Concentration of organic compounds Hexane (0,067 - 86,67) mg/m3 Acetone (0,067 - 210,00) mg/m3 Ethyl acetate (0,067 - 120,00) mg/m3 n-butyl acetate (0,067 - 116,67) mg/m3 Toluene (0,067 - 113,33) mg/m3 Xylene - mixture of isomers: 1,2-; 1,3-; 1,4- (0,067 - 113,33) mg/m3 Ethanol (0,100 - 210,00) mg/m3 Butan-2-one (0,067 - 106,67) mg/m3 4-methylpentan-2-one (0,067 - 106,67) mg/m3 Dichloromethane (0,067 - 86,67) mg/m3 Trichloroethene (0,067 - 96,67) mg/m3 Tetrachloroethene (0,067 - 106,67) mg/m3 Propan-2-ol (0,067 - 200,00) mg/m3 Butan-2-ol (0,067 - 106,67) mg/m3 Propan-1-ol (0,067 - 106,67) mg/m3 2-Methylpropan-1-ol (0,067 - 106,67) mg/m3 Butan-1-ol (0,067 - 67,00) mg/m3 Ethylbenzene (0,067 - 113,33) mg/m3 Cumene (0,067 - 113,33) mg/m3 1,3,5- trimethylbenzene (0,067 - 113,33) mg/m3 1,2,4- trimethylbenzene (0,067 - 113,33) mg/m3 1,2,3- trimethylbenzene (0,067 - 113,33) mg/m3 1-Methoxypropan-2-ol (0,133 - 120,00) mg/m3 2-Methoxy-1-methylethyl acetate (0,100 - 126,67) mg/m3 Cyclohexanone (0,100 - 60,00) mg/m3 2-butoxyethanol (0,100 - 120,00) mg/m3 2-butoxyethyl acetate (0,100 - 120,00) mg/m3 Styrene (0,033 - 60,00) mg/m3 Extraction naphtha (0,067 - 180,00) mg/m3 Benzene (0,033 - 5,67) mg/m3 Regulated area: The method is applicable as a reference method in the regulated area (see page 11) |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN 13649:2005 * | PB-23 issue 3 of 22.04.2024 | |
| 179 | Waste gases | Phenol concentration Range (0,5 - 105) mg/m3 Regulated area: The method is applicable as a reference method in the regulated area (see page 11) |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04008-4:1999 * | PB-29 issue 2 of 22.04.2024 | |
| 180 | Waste gases | Concentration of aliphatic hydrocarbons (C4 – C10) in air Range (0,66 - 233,0) mg/m3 Regulated area: The method is applicable as a reference method in the regulated area (see page 11) |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN 13649:2005 * | PB-36 issue 2 of 22.04.2024 | |
| 181 | Waste gases | Kerosene concentration Range (0,83 - 200,0) mg/m3 Regulated area: The method is applicable as a reference method in the regulated area (see page 11) |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN 13649:2005 * | PB-32 issue 2 of 22.04.2024 | |
| 182 | Waste gases | Vinyl acetate concentration Range (0,40 - 310) mg/m3 Regulated area: The method is applicable as a reference method in the regulated area (see page 11) |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN 13649:2005 * | PB-31 issue 2 of 22.04.2024 | |
| 183 | Waste gases | Pentane concentration Range (0,90 - 340) mg/m3 Regulated area: The method is applicable as a reference method in the regulated area (see page 11) |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN 13649:2005 * | PB-33 issue 2 of 22.04.2024 | |
| 184 | Waste gases | Turpentine concentration Range (2,72 - 600) mg/m3 Regulated area: The method is applicable as a reference method in the regulated area (see page 11) |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN 13649:2005 * | PB-42 issue 2 of 22.04.2024 | |
| 185 | Waste gases | Ethylene glycol concentration Range (0,5 - 50) mg/m3 Regulated area: The method is applicable as a reference method in the regulated area (see page 11) |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN 13649:2005 * | PB-43 issue 3 of 22.04.2024 | |
| 186 | Workplace environment − air samples collected on sorbent tubes, General environment - waste gas samples collected on sorbent tubes | Phenol content Range (0,015 - 0,50) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PB-29 issue 2 of 22.04.2024 | |
| 187 | Workplace environment − air samples collected on sorbent tubes, General environment - waste gas samples collected on sorbent tubes | Content of aliphatic hydrocarbons (C4 – C10) in air Range (0,020 - 0,7) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04017-03:1990 excluding cl. 8 | |
| 188 | Workplace environment − air samples collected on sorbent tubes, General environment - waste gas samples collected on sorbent tubes | Kerosene content Range (0,015 - 1,0) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04227-02:1992 excluding cl. 8 | |
| 189 | Workplace environment − air samples collected on sorbent tubes, General environment - waste gas samples collected on sorbent tubes | Vinyl acetate content Range (0,005 - 0,93) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID | PN-Z-04178-02:1987 excluding cl. 8 | |
| 190 | Workplace environment − air samples collected on sorbent tubes, General environment - waste gas samples collected on sorbent tubes | Pentane content Range (0,005 - 1,02 ) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04318:2005 excluding cl. 8 | |
| 191 | Workplace environment − air samples collected on sorbent tubes, General environment - waste gas samples collected on sorbent tubes | Turpentine content Range (0,082 - 3,0) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PB-42 issue 2 of 22.04.2024 | |
| 192 | Workplace environment − air samples collected on sorbent tubes, General environment - waste gas samples collected on sorbent tubes | Ethylene glycol content Range (0,02 - 2,0) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PB-43 issue 3 of 22.04.2024 | |
| 193 | Workplace environment − air samples collected on sorbent tubes, General environment - waste gas samples collected on sorbent tubes | Content of organic compounds Hexane (0,002 - 0,31) mg in the sample Acetone (0,002 - 0,77) mg in the sample Ethyl acetate (0,002 - 0,39) mg in the sample n-butyl acetate (0,002 - 0,36) mg in the sample Toluene (0,002 - 0,36) mg in the sample Xylene - mixture of isomers: 1,2-; 1,3-; 1,4- (0,002 - 0,36) mg in the sample Ethanol (0,003 - 0,64) mg in the sample Butan-2-one (0,002 - 0,39) mg in the sample 4-methylpentan-2-one (0,002 - 0,39) mg in the sample Dichloromethane (0,002 - 0,30) mg in the sample Trichloroethene (0,002 - 0,31) mg in the sample Tetrachloroethene (0,002 - 0,32) mg in the sample Propan-2-ol (0,002 - 0,63) mg in the sample Butan-2-ol (0,002 - 0,36) mg in the sample Propan-1-ol (0,002 - 0,39) mg in the sample 2-Methylpropan-1-ol (0,002 - 0,39) mg in the sample Butan-1-ol (0,002 - 0,20) mg in the sample Ethylbenzene (0,002 - 0,37) mg in the sample Cumene (0,002 - 0,36) mg in the sample 1,3,5- trimethylbenzene (0,002 - 0,38) mg in the sample 1,2,4- trimethylbenzene (0,002 - 0,36) mg in the sample 1,2,3- trimethylbenzene (0,002 - 0,38) mg in the sample 1-Methoxypropan-2-ol (0,004 - 0,39) mg in the sample 2-Methoxy-1-methylethyl acetate (0,003 - 0,40) mg in the sample Cyclohexanone (0,003 - 0,23) mg in the sample 2-butoxyethanol (0,003 - 0,38) mg in the sample 2-butoxyethyl acetate (0,003 - 0,40) mg in the sample Styrene (0,001 - 0,19) mg in the sample Extraction naphtha (0,002 - 0,57) mg in the sample Benzene (0,001 - 0,02) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PB-23 issue 3 of 22.04.2024 | |
Reference standards (117)
ISO 12039:2019
ISO 15713:2006
PB- 08 issue 3 of 03.01.2011
PB-01 issue 4 of 15.01.2014
PB-04 issue 1 of 01.09.2020
PB-07 issue 2 of 09.01.2009
PB-09 issue 1 of 07.04.2026
PB-10 issue 3 of 03.01.2011
PB-11 issue 2 of 09.01.2009
PB-13 issue 5 of 22.04.2024
PB-14 issue 5 of 22.04.2024
PB-15 issue 5 of 29.08.2023
PB-16 issue 5 of 22.04.2024
PB-17 issue 5 of 22.04.2024
PB-18 issue 3 of 22.04.2024
PB-19 issue 5 of 22.04.2024
PB-22 issue 4 of 04.02.2020
PB-23 issue 3 of 22.04.2024
PB-24 issue 2 of 03.01.2011
PB-26 issue 2 of 03.01.2011
PB-27 issue 1 of 07.01.2010
PB-28 issue 1 of 07.01.2010
PB-29 issue 2 of 22.04.2024
PB-31 issue 2 of 22.04.2024
PB-32 issue 2 of 22.04.2024
PB-33 issue 2 of 22.04.2024
PB-34 issue 1 of 10.05.2010
PB-35 issue 1 of 10.05.2010
PB-36 issue 2 of 22.04.2024
PB-41 issue 3 of 09.01.2012
PB-42 issue 2 of 22.04.2024
PB-43 issue 3 of 22.04.2024
PB-45 issue 1 of 15.12.2016 based on the Merck cuvette test 1.14540
PB-47 issue 4 of 27.07.2026
PN-C-04541:1978
PN-C-04584:1977
PN-EN 1233:2000
PN-EN 12619:2013
PN-EN 13211:2006
PN-EN 13284-1:2018-02
PN-EN 13649:2005
PN-EN 13649:2005 *
PN-EN 14253+A1:2011
PN-EN 14385:2025-05
PN-EN 14789:2017-4
PN-EN 14790:2017-04
PN-EN 14791:2017-04
PN-EN 14792:2017-4
PN-EN 15058:2017-4
PN-EN 1838:2025-05 excluding cl. 5.1.3, 5.1.4, 5.1.7, 5.1.8, 5.2.3, 5.2.4, 5.2.7, 5.3.4, 5.3.5, 5.3.7, 5.3.8, 6, 7
PN-EN 1911:2011
PN-EN 1948-1:2006
PN-EN 27888:1999
PN-EN 458:2016-06
PN-EN 872:2007 + Ap1:2007
PN-EN ISO 10523:2012
PN-EN ISO 11079:2008
PN-EN ISO 16911-1:2013
PN-EN ISO 19458:2007
PN-EN ISO 21877:2020-03
PN-EN ISO 23210:2010
PN-EN ISO 4869-2:2018-2
PN-EN ISO 5349-1:2004
PN-EN ISO 5349-2:2004
PN-EN ISO 5349-2:2004/A1:2015-11
PN-EN ISO 5667-6:2016-12 excluding cl. 7.4, 7.5, 7.6
PN-EN ISO 5815-1:2019-12
PN-EN ISO 7243:2018-01 +Ap2:2020-04P
PN-EN ISO 7730:2006+Ap2:2016-04
PN-EN ISO 9612:2025-11
PN-EN ISO 9612:2025-11 excluding the method covering strategy 2 - cl. 10 and strategy 3 - cl. 11
PN-ISO 10396:2001
PN-ISO 5667-10:2021-11
PN-ISO 5667-5:2017-10
PN-ISO 6060:2006
PN-ISO 8288:2002; Method A
PN-ISO 8518:1994
PN-N-01307:1994
PN-Z 04502:2019-10
PN-Z-04007-2:1994
PN-Z-04008-4:1999
PN-Z-04008-4:1999 *
PN-Z-04008-7:2002+Az1:2004
PN-Z-04009-11:2008
PN-Z-04017-03:1990 excluding cl. 8
PN-Z-04030-7:1994
PN-Z-04037-03:1975
PN-Z-04041:1971
PN-Z-04045-02:1976
PN-Z-04045-06:1982
PN-Z-04100-03:1987
PN-Z-04102-3:2013
PN-Z-04106-3:2002
PN-Z-04134-02:1981
PN-Z-04152-02:1986
PN-Z-04178-02:1987
PN-Z-04178-02:1987 excluding cl. 8
PN-Z-04227-02:1992
PN-Z-04227-02:1992 excluding cl. 8
PN-Z-04263-1:2012
PN-Z-04318:2005
PN-Z-04318:2005 excluding cl. 8
PN-Z-04333:2006
PN-Z-04434:2011
PN-Z-04442-10:2023-05
PN-Z-04469:2025-02
PN-Z-04472:2015-10
PN-Z-04488:2017-10
PN-Z-04507:2022-05
PN-Z-04507:2022-05/Ap1:2022-08
PN-Z-04508:2022-05
PN-Z-04508:2022-05/Ap1:2022-08
PiMOŚP 2012 No. 4 (74) pp. 117-130
Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023 item 1706) - excluding cl. F
based on Merck test 1.14537 and 1.14763
based on Merck test 1.14551
based on Nanocolor test 1-48