🇵🇱 LEMITOR OCHRONA ŚRODOWISKA Sp. z o. o. PL

PCA AB 912 • Wrocław, Poland • 114 methods

EnvironmentMaterials & polymers

LEMITOR OCHRONA ŚRODOWISKA Sp. z o. o. is a laboratory accredited by PCA under number AB 912 (Wrocław, Poland). Its accreditation scope covers 114 test methods in the following areas: Environment, Materials & polymers. Test objects include: Waste gases, Waste gases, Waste gas samples collected into absorbing solution, General environment − ambient air – ambient air samples collected i…, General environment − ambient air. Most frequently used techniques: Spectrophotometric method, Direct measurement method, Inductively coupled plasma optical emission spectrometry (ICP-OES).

At a glance

  • Accreditation number: PCA AB 912
  • Methods in scope: 114
  • Types of test objects: 16
  • Techniques used: 23
  • City: Wrocław, Poland
Accreditation number
AB 912
Accreditation body
PCA
Address
LABORATORIUM BADAWCZE, ul. Jana Długosza 40, 51-162 Wrocław
City
Wrocław, Poland

What this laboratory tests (16)

Analytical techniques used (23)

Laboratory locations

Certificate information

Issue date
30.06.2026
Issue no.
22

Accreditation scope — test methods (114)

No. Test object Methodology / Parameters Technique Reference document
Testing Laboratory
1 Waste gases Gas volume flow rate for dynamic pressures > 10 Pa
Velocity Range (1 – 20) m/s
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
Stagnation pressure method; Anemometric method PN-Z-04030-7:1994
2 Waste gases Dust sampling for determination of dust concentration
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
PN-Z-04030-7:1994
3 Waste gases Dust concentration
Range (0,0005 – 100) g/m3
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
Gravimetric method PN-Z-04030-7:1994
4 Waste gases Dust emission (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
PN-Z-04030-7:1994
5 Waste gases Concentration of sulphur dioxide, carbon monoxide, carbon dioxide, nitrogen oxides, nitrogen monoxide, oxygen
SO2 (3 – 2900) mg/m3 CO (2,5 – 6250) mg/m3 CO2 (0,1 − 20) % NOX (2 – 4900) mg/m3 NO (2 – 3200) mg/m3 O2 (0,4 – 21) % O2 (0,4 – 21) %
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
NDIR method; Chemiluminescence method; Electrochemical method; Paramagnetic method PN-ISO 10396:2001
6 Waste gases Emission of SO2, CO, CO2, NO, NOx (NO and NO2 calculated as NO2), O2 (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
PN-ISO 10396:2001
7 Waste gases Mass concentration of total gaseous organic carbon (TVOC)
Range (2 – 1000) mg/m3
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
Continuous flame ionization detection method (FID) PN-EN 12619:2013
8 Waste gases TVOC emission (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
PN-EN 12619:2013
9 Waste gases Sampling for determination of hydrogen chloride concentration
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
PN-EN 1911:2011
10 Waste gases Hydrogen chloride concentration/content
Range (0,20 − 200) mg/m3 Range (0,020 – 12,0) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
Spectrophotometric method PN-EN 1911:2011
11 Waste gases Hydrogen chloride emission (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
PN-EN 1911:2011
12 Waste gases Concentration of nitrogen oxides, nitrogen monoxide
NOX (2,1 – 4900) mg/m3 NO (1,4 – 3200) mg/m3
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
Chemiluminescence method CLA PN-EN 14792:2017-04
13 Waste gases NO, NOx emission (NO and NO2 calculated as NO2) (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
PN-EN 14792:2017-04
14 Waste gases Carbon monoxide concentration
Range (2,5 – 6250) mg/m3
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
Non-dispersive infrared spectrometry method NDIR PN-EN 15058:2017-04
15 Waste gases CO emission (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
PN-EN 15058:2017-04
16 Waste gases Oxygen concentration
Range (0,4 - 21) %
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
Paramagnetic method PN-EN 14789:2017-04
17 Waste gases Carbon dioxide concentration
Range (0,1 – 20) %
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
Non-dispersive infrared spectrometry method NDIR ISO 12039:2019
18 Waste gases CO2 emission (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
ISO 12039:2019
19 Waste gases Sampling for determination of dust concentration
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
PN-EN 13284-1:2018-02
20 Waste gases Dust concentration
Range (0,5 – 50) mg/m3
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
Gravimetric method PN-EN 13284-1:2018-02
21 Waste gases Dust emission (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
PN-EN 13284-1:2018-02
22 Waste gases Water vapour concentration (H2O)
Range (4 – 40) % Range (29- 250) g/m3
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
Condensation-adsorption method PN-EN 14790:2017-04
23 Waste gases Sampling for determination of SO2 concentration
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
PN-EN 14791:2017-4
24 Waste gases Sulfur dioxide SO2 concentration
Range (0,83 – 1330) mg/m3 Range (0,1 – 40) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
Thoron method PN-EN 14791:2017-4
25 Waste gases SO2 emission (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
PN-EN 14791:2017-4
26 Waste gases Sampling for determination of hydrogen fluoride concentration
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
ISO 15713:2006
27 Waste gases Hydrogen fluoride concentration/content
Range (0,1 – 200) mg/m3 Range (0,011 – 52,6) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
Potentiometric method ISO 15713:2006
28 Waste gases Hydrogen fluoride emission (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
ISO 15713:2006
29 Waste gases Sampling for the determination of metal concentrations (As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
PN-EN 14385:2005
30 Waste gases Metal concentrations/contents:
antimony (0,00030 – 20) mg/m3 Range (0,0030 – 2,0) mg in the sample arsenic (0,000015 – 20) mg/m3 (0,00015 – 2,0) mg in the sample chromium (0,000030 – 1700) mg/m3 (0,0030 – 170) mg in the sample cadmium (0,000015 – 10) mg/m3 (0,00015 – 1,0) mg in sample cobalt (0,000015 – 20) mg/m3 (0,00015 – 2,0) mg in sample manganese (0,00030 – 20) mg/m3 (0,0030 – 2,0) mg in sample copper (0,00030 – 35) mg/m3 (0,0030 – 3,5) mg in the sample nickel (0,00030 – 150) mg/m3 (0,0030 – 15) mg in the sample lead (0,00030 – 500) mg/m3 (0,0030 – 50) mg in the sample vanadium (0,000015 – 20) mg/m3 (0,00015 – 2,0) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN 14385:2005
31 Waste gases Emission of metals (As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V) (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
PN-EN 14385:2005
32 Waste gases Sampling for determination of total mercury concentration
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
PN-EN 13211+AC:2006
33 Waste gases Hg emission (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
PN-EN 13211+AC:2006
34 Waste gases Sampling for determination of the concentration of individual gaseous organic compounds
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
PN-EN 13649:2005
35 Waste gases Metal content:
antimony (0,0030 – 2,0) mg in the sample arsenic (0,00030 – 2,0) mg in the sample chromium (0,0030 – 170) mg in the sample cadmium (0,00015 – 1,0) mg in the sample cobalt (0,00015 – 2,0) mg in the sample manganese (0,0030 – 2,0) mg in the sample copper (0,0030 – 3,5) mg in the sample nickel (0,0030 – 15) mg in the sample lead (0,0030 – 50) mg in the sample vanadium (0,00015 – 2,0) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN 14385:2005
36 Waste gases Concentration/content of individual gaseous organic compounds
Range 1,2,4-trimethylbenzene Range (0,25 – 2000) mg/m3 Range (0,0050 – 10) mg in the sample acetone (0,25 – 2000) mg/m3 (0,0050 – 10) mg in sample acrolein (0,25 – 400) mg/m3 (0,0050 – 2) mg in sample diacetone alcohol (0,25 – 2000) mg/m3 (0,0050 – 10) mg in sample benzene (0,25 – 2000) mg/m3 (0,0050 – 10) mg in sample butanol (0,25 – 2000) mg/m3 (0,0050 – 10) mg in sample butyl glycol (0,25 – 400) mg/m3 (0,0050 – 20) mg in sample methylene chloride (0,25 – 2000) mg/m3 (0,0050 – 10) mg in sample cyclohexane (0,25 – 2000) mg/m3 (0,0050 – 10) mg in sample cyclohexanol (0,25 – 2000) mg/m3 (0,0050 – 10) mg in the sample cyclohexanone (0,25 – 2000) mg/m3 (0,0050 – 10) mg in sample epichlorohydrin (0,25 – 2000) mg/m3 (0,0050 – 10) mg in sample ethanol (0,25 – 2000) mg/m3 (0,0050 – 10) mg in sample ethylbenzene (0,25 – 2000) mg/m3 (0,0050 – 10) mg in sample phenol (0,25 – 400) mg/m3 (0,0050 – 2) mg in sample benzyl butyl phthalate (0,25 – 400) mg/m3 (0,0050-2) mg in sample diethyl phthalate (0,25 – 400) mg/m3 (0,0050 – 2) mg in sample dibutyl phthalate (0,25 – 400) mg/m3 (0,0050 – 2) mg in sample dimethyl phthalate (0,25 – 400) mg/m3 (0,0050 – 2) mg in sample dioctyl phthalate (0,25 – 400) mg/m3 (0,0050-2) mg in sample bis(2-ethylhexyl) phthalate (0,25 – 400) mg/m3 (0,0050 – 2) mg in sample hexane (0,25 – 2000) mg/m3 (0,0050 – 10) mg in sample isobutanol (0,25 – 2000) mg/m3 (0,0050 – 10) mg in sample isopropanol (0,25 – 2000) mg/m3 (0,0050 – 10) mg in the sample xylene (0,25 – 2000) mg/m3 (0,0050 – 10) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
PN-EN 13649:2005
37 Waste gases Concentration/content of individual gaseous organic compounds
cumene (0,25 – 2000) mg/m3 Range (0,0050 – 10) mg in the sample acetic acid (0,25 – 400) mg/m3 (0,0050 – 10) mg in sample methyl methacrylate (0,25 – 2000) mg/m3 (0,0050 – 10) mg in sample methanol (0,25 – 2000) mg/m3 (0,0050 – 10) mg in sample methyl ethyl ketone (0,25 – 2000) mg/m3 (0,0050 – 10) mg in sample methyl isobutyl ketone (0,25 – 2000) mg/m3 (0,0050 – 10) mg in sample mesitylene (1,3,5-trimethylbenzene) (0,25 – 2000) mg/m3 (0,0050 – 10) mg in sample butyl acetate (0,25 – 2000) mg/m3 (0,0050 – 10) mg in sample ethyl acetate (0,25 – 2000) mg/m3 (0,0050 – 10) mg in sample methyl acetate (0,25 – 2000) mg/m3 (0,0050 – 10) mg in sample vinyl acetate (0,25 – 2000) mg/m3 (0,0050 – 10) mg in sample pentane (0,25 – 2000) mg/m3 (0,0050 – 10) mg in sample propylbenzene (0,25 – 2000) mg/m3 (0,0050 – 10) mg in sample styrene (0,25 – 2000) mg/m3 (0,0050 – 10) mg in sample toluene (0,25 – 2000) mg/m3 (0,0050 – 10) mg in sample aliphatic hydrocarbons (sum C5 - C12) (0,25 – 2000) mg/m3 (0,0050 – 10) mg in sample aromatic hydrocarbons (sum) (0,25 – 2000) mg/m3 (0,0050 – 10) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005
38 Waste gases Emission of individual gaseous organic compounds (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
PN-EN 13649:2005
39 Waste gases Concentration of sulphur dioxide, carbon monoxide, nitrogen monoxide, nitrogen dioxide, oxygen
SO2 (3 – 2900) mg/m3 CO (2,5 – 6250) mg/m3 NO (1,4 – 4020) mg/m3 NO2 (4 – 990) mg/m3 O2 (2 – 21) %
Electrochemical method PN-ISO 10396:2001 | PB-03 edition 4 of 01.02.2023
40 Waste gases Emission of SO2, CO, NO and NOx (calculated as NO2) (calculated) PN-ISO 10396:2001 | PB-03 edition 4 of 01.02.2023
41 Waste gases Sampling for determination of the concentration of: ammonia chlorine, fluorine and fluorides, formaldehyde, isocyanates – MDI, TDI, sulfuric acid, hydrogen sulfide, hydrogen cyanide Aspiration method using absorbing solutions PB-16B edition 2 of 01.02.2023
42 Waste gases Sampling for determination of the concentration of organosulfur compounds and methane Isolation method using Tedlar bags PB-61 edition 4 of 01.02.2023
43 Waste gases, Waste gas samples collected into absorbing solution Ammonia concentration/content
Range (0,5 – 800) mg/m3 (0,020 − 8) mg in the sample
Spectrophotometric method PB-11 edition 9 of 01.02.2023
44 Waste gases, Waste gas samples collected into absorbing solution Ammonia emission (calculated) PB-11 edition 9 of 01.02.2023
45 Waste gases, Waste gas samples collected into absorbing solution Sampling for determination of ammonia concentration PN-EN ISO 21877:2020-03
46 Waste gases, Waste gas samples collected into absorbing solution Ammonia concentration/content
Range (0,09 − 190) mg/m3 Range (0,01 – 11,25) mg in the sample
Spectrophotometric method PN-EN ISO 21877:2020-03
47 Waste gases, Waste gas samples collected into absorbing solution Ammonia emission (calculated) PN-EN ISO 21877:2020-03
48 Waste gases, Waste gas samples collected into absorbing solution Chlorine concentration/content
Range (0,05 − 1) mg/m3 (0,002 − 0,014) mg in sample
Spectrophotometric method PB-13 edition 7 of 01.02.2023
49 Waste gases, Waste gas samples collected into absorbing solution Chlorine emission (calculated) PB-13 edition 7 of 01.02.2023
50 Waste gases, Waste gas samples collected into absorbing solution Sampling for determination of the concentration of fluorine and its compounds ISO 15713:2006
51 Waste gases, Waste gas samples collected into absorbing solution Concentration/content of fluorine and its compounds
Range (0,1 – 200) mg/m3 Range (0,010 – 50) mg in sample
Potentiometric method ISO 15713:2006
52 Waste gases, Waste gas samples collected into absorbing solution Emission of fluorine and its compounds (calculated) ISO 15713:2006
53 Waste gases, Waste gas samples collected into absorbing solution Concentration/content of fluorine and fluorides
Range (0,1 − 8000) mg/m3 (0,0040 − 20) mg in sample
Potentiometric method PB-15 edition 6 of 01.02.2023
54 Waste gases, Waste gas samples collected into absorbing solution Emission of fluorine and fluorides (calculated) PB-15 edition 6 of 01.02.2023
55 Waste gases, Waste gas samples collected into absorbing solution Formaldehyde concentration/content
Range (0,050 − 160) mg/m3 (0,0020 − 1,6) mg in the sample
Spectrophotometric method PB-06 edition 9 of 01.02.2023
56 Waste gases, Waste gas samples collected into absorbing solution Formaldehyde emission (calculated) PB-06 edition 9 of 01.02.2023
57 Waste gases, Waste gas samples collected into absorbing solution Concentration/content of isocyanates - MDI
Range (0,156 − 250) mg/m3 (0,00625 − 2,5) mg in sample
Spectrophotometric method PB-09 edition 7 of 01.02.2023
58 Waste gases, Waste gas samples collected into absorbing solution Emission of isocyanates - MDI (calculated) PB-09 edition 7 of 01.02.2023
59 Waste gases, Waste gas samples collected into absorbing solution Concentration/content of isocyanates - TDI
Range (0,10 − 320) mg/m3 (0,0040 − 3,2) mg in sample
Spectrophotometric method PB-10 edition 7 of 01.02.2023
60 Waste gases, Waste gas samples collected into absorbing solution Emission of isocyanates - TDI (calculated) PB-10 edition 7 of 01.02.2023
61 Waste gases, Waste gas samples collected into absorbing solution Sulfuric acid concentration/content
Range (0,375 − 480) mg/m3 (0,015 − 4,9) mg in the sample
Spectrophotometric method PB-07 edition 6 of 01.02.2023
62 Waste gases, Waste gas samples collected into absorbing solution Sulfuric acid emission (calculated) PB-07 edition 6 of 01.02.2023
63 Waste gases, Waste gas samples collected into absorbing solution Hydrogen sulphide concentration/content
Range (0,075 − 320) mg/m3 (0,0030 − 3,2) mg in the sample
Spectrophotometric method PB-58 edition 5 of 01.02.2023
64 Waste gases, Waste gas samples collected into absorbing solution Hydrogen sulphide emission (calculated) PB-58 edition 5 of 01.02.2023
65 Waste gases, Waste gas samples collected into absorbing solution Metal content:
barium (0,0030 – 0,50) mg in the sample boron (0,0030 – 2,0) mg in the sample bismuth (0,015 – 2,0) mg in the sample tin (0,015 – 2,0) mg in the sample zinc (0,015 – 50) mg in the sample molybdenum(0,0030 – 2,0) mg in the sample selenium (0,015 – 1,0) mg in the sample titanium (0,015 – 2,0) mg in the sample iron (0,010 – 50) mg in the sample
Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN 14385:2005
66 Waste gases, Waste gas samples collected on filters Dust sampling for determination of metal concentrations in dust (Cr, Zn, Cd, Co, Mg, Mn, Cu, Ni, Pb, K, Ag, Fe, Sn, As, Cr, V, Bi, B, Ba, Mo, Se, Ti), Sampling for determination of metal concentrations (Zn, Mg, K, Ag, Fe, Sn, Bi, B, Ba, Mo, Se, Ti) PN-Z-04030-7:1994 | PN-EN 14385:2005
67 Waste gases, Waste gas samples collected on filters Metal concentrations/contents:
boron (0,00030 – 20) mg/m3 Range (0,0030 – 2,0) mg in the sample barium (0,00030 – 5,0) mg/m3 (0,0030 – 0,50) mg in sample bismuth (0,0015 – 20) mg/m3 (0,015 – 2,0) mg in the sample tin (0,0015 – 20) mg mg/m3 (0,015 – 2,0) mg in sample zinc (0,0015 – 500) mg/m3 (0,015 – 50) mg in the sample molybdenum (0,000030 – 20) mg/m3 (0,00030 – 2,0) mg in the sample selenium (0,0015 – 10) mg/m3 (0,015 – 1,0) mg in the sample titanium (0,0015 – 20) mg/m3 (0,015 – 2,0) mg in the sample iron (0,0010 – 500) mg/m3 (0,010 – 50) mg in sample
Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-Z-04030-7:1994 | PN-EN 14385:2005
68 Waste gases, Waste gas samples collected on filters Emission of metals (B, Ba, Bi, Sn, Zn, Mo, Se, Ti, Fe) (calculated) PN-Z-04030-7:1994 | PN-EN 14385:2005
69 Landfill gases Concentration of methane, carbon dioxide, oxygen
CH4 (0,5 – 70) % CO2 (0,5 – 60) % O2 (0,5 – 25) %
Infrared spectrophotometry method; Electrochemical method PB-14 edition 4 of 01.02.2023
70 Landfill gases Velocity
Range (0,5 – 10) m/s
Anemometric method PB-14 edition 4 of 01.02.2023
71 Landfill gases Emission of methane, carbon dioxide (calculated) PB-14 edition 4 of 01.02.2023
72 General environment − ambient air Carbon monoxide (CO) concentration
Range (2,5 – 500) mg/m3
Non-dispersive infrared spectrometry (NDIR) PB-02 edition 6 of 17.03.2025
73 General environment − ambient air Volatile organic compounds (VOC) concentration expressed as total organic carbon (TOC)
Range (1 – 100) mg/m3
Continuous flame ionization detection method (FID) PB-30 edition 6 of 17.03.2025
74 General environment − ambient air Dust sampling for testing PB-01 edition 6 of 21.02.2025
75 General environment − ambient air Dust concentration
Range (0,0055 – 10) mg/m3
Gravimetric method PB-01 edition 6 of 21.02.2025
76 General environment − ambient air Sampling for determination of the concentration of: ammonia, chlorine, hydrogen chloride, fluorine and its compounds, formaldehyde, isocyanates – MDI, TDI, sulfuric acid, hydrogen sulfide Aspiration method using absorbing solutions PB-16A edition 2 of 01.02.2023
77 General environment − ambient air Sampling for the determination of organic compound concentration Aspiration method using activated carbon, silica gel, chromosorb, XAD-2 PB-16A edition 2 of 01.02.2023
78 General environment − ambient air Sampling for determination of the concentration of organosulfur compounds and methane Isolation method using Tedlar bags PB-61 edition 4 of 01.02.2023
79 General environment − ambient air Sampling of suspended particulate matter, PM10 or PM2,5 Aspiration method PN-EN 12341:2014 excluding cl. 5.2, 6.2, 6.4, 6.5
80 General environment − ambient air Sampling of PM10 and PM2,5 dust for determination of metal concentrations: As, Ba, B, Bi, Cd, Cr, Co, Cu, Fe, Mn, Mo, Ni, Pb, Sb, Sn, Ti, V, Zn Aspiration method PN-EN 12341:2014 excluding cl. 5.2, 6.2, 6.4, 6.5
81 General environment − ambient air – ambient air samples collected into absorbing solution Ammonia concentration/content
Range (0,25 − 400) mg/m3 (0,010 − 8) mg in the sample
Spectrophotometric method PB-11 edition 9 of 01.02.2023
82 General environment − ambient air – ambient air samples collected into absorbing solution Chlorine concentration/content
Range (0,05 – 0,5) mg/m3 (0,002 − 0,014) mg in sample
Spectrophotometric method PB-13 edition 7 of 01.02.2023
83 General environment − ambient air – ambient air samples collected into absorbing solution Hydrogen chloride concentration/content
Range (0,5 - 10) mg/m3 Range (0,02 – 4,0) mg in the sample
Spectrophotometric method PB-12 edition 6 of 01.02.2023
84 General environment − ambient air – ambient air samples collected into absorbing solution Concentration/content of fluorine and its compounds
Range (0,1 − 4000) mg/m3 (0,0040 − 20) mg in sample
Potentiometric method PB-15 edition 6 of 01.02.2023
85 General environment − ambient air – ambient air samples collected into absorbing solution Formaldehyde concentration/content
Range (0,025 − 40) mg/m3 (0,0010 − 0,8) mg in the sample
Spectrophotometric method PB-06 edition 9 of 01.02.2023
86 General environment − ambient air – ambient air samples collected into absorbing solution Concentration/content of isocyanates - MDI
Range (0,156 − 125) mg/m3 (0,00625 − 2,5) mg in sample
Spectrophotometric method PB-09 edition 7 of 01.02.2023
87 General environment − ambient air – ambient air samples collected into absorbing solution Concentration/content of isocyanates - TDI
Range (0,100 − 250) mg/m3 (0,0040 − 3,2) mg in sample
Spectrophotometric method PB-10 edition 7 of 01.02.2023
88 General environment − ambient air – ambient air samples collected into absorbing solution Sulfuric acid concentration/content
Range (0,375 − 120) mg/m3 Range (0,015 – 2,45) mg in the sample
Spectrophotometric method PB-07 edition 6 of 01.02.2023
89 General environment − ambient air – ambient air samples collected into absorbing solution Hydrogen sulphide concentration/content
Range (0,019 − 0,5) mg/m3 (0,0015 − 0,010) mg in the sample
Spectrophotometric method PB-58 edition 5 of 01.02.2023
90 General environment − ambient air – ambient air samples collected into absorbing solution Sampling for determination of NO2 concentration PN-Z-04009-9:1997
91 General environment − ambient air – ambient air samples collected into absorbing solution NO2 concentration/content
Range (12,6 – 6285) μg/m3 Range (0,40 – 200) μg in the sample
Spectrophotometric method PN-Z-04009-9:1997
92 General environment − ambient air – ambient air samples collected into absorbing solution Sampling for determination of SO2 concentration PN-ISO 6767:1997
93 General environment − ambient air – ambient air samples collected into absorbing solution SO2 concentration/content
Range (26,7 – 853) μg/m3 Range (1,6 – 25,6) μg in the sample
Spectrophotometric method PN-ISO 6767:1997
94 General environment − ambient air − ambient air samples collected on sorbent tubes Concentration/content of organic compounds
Range 1,2,4-trimethylbenzene Range (0,00260 – 125) mg/m3 Range (0,0050 – 10) mg in the sample acetone (0,00260 – 125) mg/m3 (0,0050 – 10) mg in sample acrolein (0,00260 – 25) mg/m3 (0,0050 – 2) mg in sample diacetone alcohol (0,00260 – 125) mg/m3 (0,0050 – 10) mg in sample benzene (0,00260 – 125) mg/m3 (0,0050 – 10) mg in sample butanol (0,00260 – 125) mg/m3 (0,0050 – 10) mg in sample butyl glycol (0,00260 – 25) mg/m3 (0,0050 – 20) mg in sample methylene chloride (0,00260 – 125) mg/m3 (0,0050 – 10) mg in sample cyclohexane (0,00260 – 125) mg/m3 (0,0050 – 10) mg in sample cyclohexanol (0,00260 – 125) mg/m3 (0,0050 – 10) mg in the sample Cyclohexanone (0,00260 – 125) mg/m3 (0,0050 – 10) mg in sample epichlorohydrin (0,00260 – 125) mg/m3 (0,0050 – 10) mg in sample ethanol (0,00260 – 125) mg/m3 (0,0050 – 10) mg in sample ethylbenzene (0,00260 – 125) mg/m3 (0,0050 – 10) mg in sample phenol (0,00260 – 25) mg/m3 (0,0050 – 2) mg in sample benzyl butyl phthalate (0,00260 – 25) mg/m3 (0,0050-2) mg in sample diethyl phthalate (0,00260 – 25) mg/m3 (0,0050 – 2) mg in sample dibutyl phthalate (0,00260 – 25) mg/m3 (0,0050 – 2) mg in sample dimethyl phthalate (0,00260 – 25) mg/m3 (0,0050 – 2) mg in sample dioctyl phthalate (0,00260 – 25) mg/m3 (0,0050-2) mg in sample bis(2-ethylhexyl) phthalate (0,00260 – 25) mg/m3 (0,0050 – 2) mg in sample hexane (0,00260 – 125) mg/m3 (0,0050 – 10) mg in sample isobutanol (0,00260 – 125) mg/m3 (0,0050 – 10) mg in sample isopropanol (0,00260 – 125) mg/m3 (0,0050 – 10) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PB-05 edition 12 of 01.02.2023
95 General environment − ambient air − ambient air samples collected on sorbent tubes Concentration/content of organic compounds
xylene (0,00260 – 125) mg/m3 Range (0,0050 – 10) mg in the sample cumene (0,00260 – 125) mg/m3 (0,0050 – 10) mg in the sample acetic acid (0,00260 – 125) mg/m3 (0,0050 – 10) mg in sample methyl methacrylate (0,00260 – 125) mg/m3 (0,0050 – 10) mg in sample methanol (0,00260 – 125) mg/m3 (0,0050 – 10) mg in sample methyl ethyl ketone (0,00260 – 125) mg/m3 (0,0050 – 10) mg in sample methyl isobutyl ketone (0,00260 – 125) mg/m3 (0,0050 – 10) mg in sample mesitylene (0,00260 – 125) mg/m3 (0,0050 – 10) mg in sample butyl acetate (0,00260 – 125) mg/m3 (0,0050 – 10) mg in sample ethyl acetate (0,00260 – 125) mg/m3 (0,0050 – 10) mg in sample methyl acetate (0,00260 – 125) mg/m3 (0,0050 – 10) mg in sample vinyl acetate (0,00260 – 125) mg/m3 (0,0050 – 10) mg in sample pentane (0,00260 – 125) mg/m3 (0,0050 – 10) mg in sample propylbenzene (0,00260 – 125) mg/m3 (0,0050 – 10) mg in sample styrene (0,00260 – 125) mg/m3 (0,0050 – 10) mg in sample toluene (0,00260 – 125) mg/m3 (0,0050 – 10) mg in sample aliphatic hydrocarbons (sum C5 - C12) (0,00260 – 125) mg/m3 (0,0050 – 10) mg in sample aromatic hydrocarbons (sum) (0,00260 – 125) mg/m3 (0,0050 – 10) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PB-05 edition 12 of 01.02.2023
96 General environment – ambient air – ambient air samples collected on filters Concentration / content of metals
antimony (0,00030 – 0,56) mg/m3 Range (0,0030 – 2,0) mg in the sample arsenic (0,000015 – 0,56) mg/m3 (0,00015 – 2,0) mg in the sample boron (0,00030 – 0,56) mg/m3 (0,0030 – 2,0) mg in the sample barium (0,00030 – 0,14) mg/m3 (0,0030 – 0,50) mg in sample bismuth (0,00150 – 0,56) mg/m3 (0,015 – 2,0) mg in the sample chromium (0,00030 – 47,2) mg/m3 (0,0030 – 170) mg in the sample tin (0,00150 – 0,56) mg/m3 (0,015 – 2,0) mg in sample zinc (0,00150 – 13,9) mg/m3 (0,015 – 50) mg in the sample cadmium (0,000015 – 0,28) mg/m3 (0,00015 – 1,0) mg in sample cobalt (0,000015 – 0,56) mg/m3 (0,00015 – 2,0) mg in sample manganese (0,00030 – 0,56) mg/m3 (0,0030 – 2,0) mg in sample copper (0,00030 – 0,97) mg/m3 (0,0030 – 3,50) mg in the sample molybdenum (0,000030 – 0,56) mg/m3 (0,00030 – 2,0) mg in the sample nickel (0,00030 – 4,2) mg/m3 (0,0030 – 150) mg in the sample lead (0,00030 – 13,9) mg/m3 (0,0030 – 50) mg in the sample titanium (0,00150 – 0,56) mg/m3 (0,015 – 2,0) mg in the sample vanadium (0,000015 – 0,56) mg/m3 (0,00015 – 2,0) mg in the sample iron (0,0010 – 13,9) mg/m3 (0,010 – 50) mg in sample
Inductively coupled plasma optical emission spectrometry (ICP-OES) PB-60 edition 3 of 01.02.2023
97 General environment – ambient air – ambient air samples collected on filters – ambient air samples collected into absorbing solution Metal content:
antimony (0,0030 – 2,0) mg in the sample arsenic (0,00030 – 2,0) mg in the sample barium (0,0030 – 0,50) mg in the sample boron (0,0030 – 2,0) mg in the sample bismuth (0,015 – 2,0) mg in the sample tin (0,015 – 2,0) mg in the sample zinc (0,015 – 50) mg in the sample chromium (0,0030 – 170) mg in the sample cadmium (0,00015 – 1,0) mg in the sample cobalt (0,00015 – 2,0) mg in the sample manganese (0,0030 – 2,0) mg in the sample copper (0,0030 – 3,5) mg in the sample molybdenum(0,0030 – 2,0) mg in the sample nickel (0,0030 – 15) mg in the sample lead (0,0030 – 50) mg in the sample selenium (0,015 – 1,0) mg in the sample vanadium (0,00015 – 2,0) mg in the sample titanium (0,015 – 2,0) mg in the sample iron (0,010 – 50) mg in the sample
Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN 14385:2005
98 Rainwater and snowmelt water Sampling for chemical and physical testing Temperature of the water sample taken
Range (0,0 – 50,0) oC
PN-ISO 5667-10:1997 | PB-32 edition 4 of 01.02.2023
99 Rainwater and snowmelt water Mineral oil index C10 – C40 (petroleum hydrocarbons)
Range (0,60 – 50) mg/l
Gas chromatography with flame ionization detection (GC-FID) PN-EN ISO 9377-2:2003
100 Rainwater and snowmelt water Total suspended solids (TSS)
Range (2,0 – 1000) mg/l
Gravimetric method PN-EN 872:2007+Ap1:2007
101 General environment − noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level
Range (25 – 137) dB
Direct measurement method Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023, item 1706)
102 General environment − noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023, item 1706)
103 General environment − noise from installations, equipment and industrial plants Calculation method PN-ISO 9613-2:2002 CNOSSOS-EU (Industry)
104 General environment − impulse noise from installations and equipment A-weighted equivalent sound level A-weighted sound exposure level
Range (25 – 137) dB
Direct measurement method Annex 8 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023, item 1706) | PN-ISO 1996-2:1999+A1:2002
105 General environment − impulse noise from installations and equipment A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Annex 8 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023, item 1706) | PN-ISO 1996-2:1999+A1:2002
106 Machinery and equipment − noise A-weighted equivalent sound pressure level
Range (25 – 137) dB
Direct measurement method PN-EN ISO 3746:2011+Ap1:2017-09
107 Machinery and equipment − noise Sound power level, Sound energy level (calculated) PN-EN ISO 3746:2011+Ap1:2017-09
108 General environment – noise barriers „in situ” A-weighted equivalent sound pressure level
Range (25 − 137) dB
Direct measurement method PN-ISO 10847:2002
109 General environment – noise barriers „in situ” Effectiveness of screens (calculated) PN-ISO 10847:2002
110 General environment − noise from roads, railway lines, tram lines A-weighted equivalent sound level A-weighted sound exposure level
Range (25 – 137) dB
Direct measurement method Annex 3 to the Regulation of the Minister of the Environment of 16.06.2011 (Journal of Laws No. 140, item 824 and No. 288, item 1697)
111 General environment − noise from roads, railway lines, tram lines A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Annex 3 to the Regulation of the Minister of the Environment of 16.06.2011 (Journal of Laws No. 140, item 824 and No. 288, item 1697)
112 General environment − noise from roads, railway lines, tram lines Calculation method NMBP-Roads-1996/NFS 31-133 (XPS 31-133) NMPB-Roads-2008 CNOSSOS-EU (Road) RMR/SRM II CNOSSOS-EU (Rail)
113 General environment − noise from airports A-weighted equivalent sound level A-weighted sound exposure level
Range (25 −137) dB
Direct measurement method Annexes 1 and 2 to the Regulation of the Minister of the Environment of 16.06.2011 (Journal of Laws 2011 No. 140, item 824)
114 General environment − noise from airports A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Annexes 1 and 2 to the Regulation of the Minister of the Environment of 16.06.2011 (Journal of Laws 2011 No. 140, item 824)

Reference standards (51)

ISO 12039:2019
ISO 15713:2006
NMBP-Roads-1996/NFS 31-133 (XPS 31-133) NMPB-Roads-2008 CNOSSOS-EU (Road) RMR/SRM II CNOSSOS-EU (Rail)
PB-01 edition 6 of 21.02.2025
PB-02 edition 6 of 17.03.2025
PB-03 edition 4 of 01.02.2023
PB-05 edition 12 of 01.02.2023
PB-06 edition 9 of 01.02.2023
PB-07 edition 6 of 01.02.2023
PB-09 edition 7 of 01.02.2023
PB-10 edition 7 of 01.02.2023
PB-11 edition 9 of 01.02.2023
PB-12 edition 6 of 01.02.2023
PB-13 edition 7 of 01.02.2023
PB-14 edition 4 of 01.02.2023
PB-15 edition 6 of 01.02.2023
PB-16A edition 2 of 01.02.2023
PB-16B edition 2 of 01.02.2023
PB-30 edition 6 of 17.03.2025
PB-32 edition 4 of 01.02.2023
PB-58 edition 5 of 01.02.2023
PB-60 edition 3 of 01.02.2023
PB-61 edition 4 of 01.02.2023
PN-EN 12341:2014 excluding cl. 5.2, 6.2, 6.4, 6.5
PN-EN 12619:2013
PN-EN 13211+AC:2006
PN-EN 13284-1:2018-02
PN-EN 13649:2005
PN-EN 14385:2005
PN-EN 14789:2017-04
PN-EN 14790:2017-04
PN-EN 14791:2017-4
PN-EN 14792:2017-04
PN-EN 15058:2017-04
PN-EN 1911:2011
PN-EN 872:2007+Ap1:2007
PN-EN ISO 21877:2020-03
PN-EN ISO 3746:2011+Ap1:2017-09
PN-EN ISO 9377-2:2003
PN-ISO 10396:2001
PN-ISO 10847:2002
PN-ISO 1996-2:1999+A1:2002
PN-ISO 5667-10:1997
PN-ISO 6767:1997
PN-ISO 9613-2:2002 CNOSSOS-EU (Industry)
PN-Z-04009-9:1997
PN-Z-04030-7:1994
Annexes 1 and 2 to the Regulation of the Minister of the Environment of 16.06.2011 (Journal of Laws 2011 No. 140, item 824)
Annex 3 to the Regulation of the Minister of the Environment of 16.06.2011 (Journal of Laws No. 140, item 824 and No. 288, item 1697)
Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023, item 1706)
Annex 8 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023, item 1706)

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/PL/AB%20912