🇵🇱 LEMITOR OCHRONA ŚRODOWISKA Sp. z o. o. PL
EnvironmentMaterials & polymers
LEMITOR OCHRONA ŚRODOWISKA Sp. z o. o. is a laboratory accredited by PCA under number AB 912 (Wrocław, Poland). Its accreditation scope covers 114 test methods in the following areas: Environment, Materials & polymers. Test objects include: Waste gases, Waste gases, Waste gas samples collected into absorbing solution, General environment − ambient air – ambient air samples collected i…, General environment − ambient air. Most frequently used techniques: Spectrophotometric method, Direct measurement method, Inductively coupled plasma optical emission spectrometry (ICP-OES).
At a glance
- Accreditation number: PCA AB 912
- Methods in scope: 114
- Types of test objects: 16
- Techniques used: 23
- City: Wrocław, Poland
- Accreditation number
- AB 912
- Accreditation body
- PCA
- Address
- LABORATORIUM BADAWCZE, ul. Jana Długosza 40, 51-162 Wrocław
- City
- Wrocław, Poland
What this laboratory tests (16)
- Waste gases — 42 methods
- Waste gases, Waste gas samples collected into absorbing solution — 23 methods
- General environment − ambient air – ambient air samples collected into absorbing solution — 13 methods
- General environment − ambient air — 9 methods
- General environment − noise from installations, equipment and industrial plants — 3 methods
- General environment − noise from roads, railway lines, tram lines — 3 methods
- Landfill gases — 3 methods
- Rainwater and snowmelt water — 3 methods
- Waste gases, Waste gas samples collected on filters — 3 methods
- General environment – noise barriers „in situ” — 2 methods
- General environment − ambient air − ambient air samples collected on sorbent tubes — 2 methods
- General environment − impulse noise from installations and equipment — 2 methods
- General environment − noise from airports — 2 methods
- Machinery and equipment − noise — 2 methods
- General environment – ambient air – ambient air samples collected on filters — 1 method
- and 1 more
Analytical techniques used (23)
- Spectrophotometric method — 19 methods
- Direct measurement method — 6 methods
- Inductively coupled plasma optical emission spectrometry (ICP-OES) — 6 methods
- Gas chromatography with flame ionization detection (GC-FID) — 4 methods
- Gravimetric method — 4 methods
- Potentiometric method — 4 methods
- Aspiration method — 2 methods
- Aspiration method using absorbing solutions — 2 methods
- Calculation method — 2 methods
- Continuous flame ionization detection method (FID) — 2 methods
- Isolation method using Tedlar bags — 2 methods
- Non-dispersive infrared spectrometry method NDIR — 2 methods
- Anemometric method — 1 method
- Aspiration method using activated carbon, silica gel, chromosorb, XAD-2 — 1 method
- Chemiluminescence method CLA — 1 method
- and 8 more
Laboratory locations
- LEMITOR OCHRONA ŚRODOWISKA Sp. z o. o. (main site) — ul. Jana Długosza 40, 51-162 Wrocław
- TESTING LABORATORY — ul. Jana Długosza 40
Certificate information
- Issue date
- 30.06.2026
- Issue no.
- 22
Accreditation scope — test methods (114)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Testing Laboratory | |||||
| 1 | Waste gases | Gas volume flow rate for dynamic pressures > 10 Pa Velocity Range (1 – 20) m/s Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Stagnation pressure method; Anemometric method | PN-Z-04030-7:1994 | |
| 2 | Waste gases | Dust sampling for determination of dust concentration Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-Z-04030-7:1994 | ||
| 3 | Waste gases | Dust concentration Range (0,0005 – 100) g/m3 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Gravimetric method | PN-Z-04030-7:1994 | |
| 4 | Waste gases | Dust emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-Z-04030-7:1994 | ||
| 5 | Waste gases | Concentration of sulphur dioxide, carbon monoxide, carbon dioxide, nitrogen oxides, nitrogen monoxide, oxygen SO2 (3 – 2900) mg/m3 CO (2,5 – 6250) mg/m3 CO2 (0,1 − 20) % NOX (2 – 4900) mg/m3 NO (2 – 3200) mg/m3 O2 (0,4 – 21) % O2 (0,4 – 21) % Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
NDIR method; Chemiluminescence method; Electrochemical method; Paramagnetic method | PN-ISO 10396:2001 | |
| 6 | Waste gases | Emission of SO2, CO, CO2, NO, NOx (NO and NO2 calculated as NO2), O2 (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-ISO 10396:2001 | ||
| 7 | Waste gases | Mass concentration of total gaseous organic carbon (TVOC) Range (2 – 1000) mg/m3 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Continuous flame ionization detection method (FID) | PN-EN 12619:2013 | |
| 8 | Waste gases | TVOC emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-EN 12619:2013 | ||
| 9 | Waste gases | Sampling for determination of hydrogen chloride concentration Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-EN 1911:2011 | ||
| 10 | Waste gases | Hydrogen chloride concentration/content Range (0,20 − 200) mg/m3 Range (0,020 – 12,0) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Spectrophotometric method | PN-EN 1911:2011 | |
| 11 | Waste gases | Hydrogen chloride emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-EN 1911:2011 | ||
| 12 | Waste gases | Concentration of nitrogen oxides, nitrogen monoxide NOX (2,1 – 4900) mg/m3 NO (1,4 – 3200) mg/m3 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Chemiluminescence method CLA | PN-EN 14792:2017-04 | |
| 13 | Waste gases | NO, NOx emission (NO and NO2 calculated as NO2) (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-EN 14792:2017-04 | ||
| 14 | Waste gases | Carbon monoxide concentration Range (2,5 – 6250) mg/m3 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Non-dispersive infrared spectrometry method NDIR | PN-EN 15058:2017-04 | |
| 15 | Waste gases | CO emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-EN 15058:2017-04 | ||
| 16 | Waste gases | Oxygen concentration Range (0,4 - 21) % Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Paramagnetic method | PN-EN 14789:2017-04 | |
| 17 | Waste gases | Carbon dioxide concentration Range (0,1 – 20) % Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Non-dispersive infrared spectrometry method NDIR | ISO 12039:2019 | |
| 18 | Waste gases | CO2 emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
ISO 12039:2019 | ||
| 19 | Waste gases | Sampling for determination of dust concentration Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-EN 13284-1:2018-02 | ||
| 20 | Waste gases | Dust concentration Range (0,5 – 50) mg/m3 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Gravimetric method | PN-EN 13284-1:2018-02 | |
| 21 | Waste gases | Dust emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-EN 13284-1:2018-02 | ||
| 22 | Waste gases | Water vapour concentration (H2O) Range (4 – 40) % Range (29- 250) g/m3 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Condensation-adsorption method | PN-EN 14790:2017-04 | |
| 23 | Waste gases | Sampling for determination of SO2 concentration Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-EN 14791:2017-4 | ||
| 24 | Waste gases | Sulfur dioxide SO2 concentration Range (0,83 – 1330) mg/m3 Range (0,1 – 40) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Thoron method | PN-EN 14791:2017-4 | |
| 25 | Waste gases | SO2 emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-EN 14791:2017-4 | ||
| 26 | Waste gases | Sampling for determination of hydrogen fluoride concentration Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
ISO 15713:2006 | ||
| 27 | Waste gases | Hydrogen fluoride concentration/content Range (0,1 – 200) mg/m3 Range (0,011 – 52,6) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Potentiometric method | ISO 15713:2006 | |
| 28 | Waste gases | Hydrogen fluoride emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
ISO 15713:2006 | ||
| 29 | Waste gases | Sampling for the determination of metal concentrations (As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-EN 14385:2005 | ||
| 30 | Waste gases | Metal concentrations/contents: antimony (0,00030 – 20) mg/m3 Range (0,0030 – 2,0) mg in the sample arsenic (0,000015 – 20) mg/m3 (0,00015 – 2,0) mg in the sample chromium (0,000030 – 1700) mg/m3 (0,0030 – 170) mg in the sample cadmium (0,000015 – 10) mg/m3 (0,00015 – 1,0) mg in sample cobalt (0,000015 – 20) mg/m3 (0,00015 – 2,0) mg in sample manganese (0,00030 – 20) mg/m3 (0,0030 – 2,0) mg in sample copper (0,00030 – 35) mg/m3 (0,0030 – 3,5) mg in the sample nickel (0,00030 – 150) mg/m3 (0,0030 – 15) mg in the sample lead (0,00030 – 500) mg/m3 (0,0030 – 50) mg in the sample vanadium (0,000015 – 20) mg/m3 (0,00015 – 2,0) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Inductively coupled plasma optical emission spectrometry (ICP-OES) | PN-EN 14385:2005 | |
| 31 | Waste gases | Emission of metals (As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V) (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-EN 14385:2005 | ||
| 32 | Waste gases | Sampling for determination of total mercury concentration Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-EN 13211+AC:2006 | ||
| 33 | Waste gases | Hg emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-EN 13211+AC:2006 | ||
| 34 | Waste gases | Sampling for determination of the concentration of individual gaseous organic compounds Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-EN 13649:2005 | ||
| 35 | Waste gases | Metal content: antimony (0,0030 – 2,0) mg in the sample arsenic (0,00030 – 2,0) mg in the sample chromium (0,0030 – 170) mg in the sample cadmium (0,00015 – 1,0) mg in the sample cobalt (0,00015 – 2,0) mg in the sample manganese (0,0030 – 2,0) mg in the sample copper (0,0030 – 3,5) mg in the sample nickel (0,0030 – 15) mg in the sample lead (0,0030 – 50) mg in the sample vanadium (0,00015 – 2,0) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Inductively coupled plasma optical emission spectrometry (ICP-OES) | PN-EN 14385:2005 | |
| 36 | Waste gases | Concentration/content of individual gaseous organic compounds Range 1,2,4-trimethylbenzene Range (0,25 – 2000) mg/m3 Range (0,0050 – 10) mg in the sample acetone (0,25 – 2000) mg/m3 (0,0050 – 10) mg in sample acrolein (0,25 – 400) mg/m3 (0,0050 – 2) mg in sample diacetone alcohol (0,25 – 2000) mg/m3 (0,0050 – 10) mg in sample benzene (0,25 – 2000) mg/m3 (0,0050 – 10) mg in sample butanol (0,25 – 2000) mg/m3 (0,0050 – 10) mg in sample butyl glycol (0,25 – 400) mg/m3 (0,0050 – 20) mg in sample methylene chloride (0,25 – 2000) mg/m3 (0,0050 – 10) mg in sample cyclohexane (0,25 – 2000) mg/m3 (0,0050 – 10) mg in sample cyclohexanol (0,25 – 2000) mg/m3 (0,0050 – 10) mg in the sample cyclohexanone (0,25 – 2000) mg/m3 (0,0050 – 10) mg in sample epichlorohydrin (0,25 – 2000) mg/m3 (0,0050 – 10) mg in sample ethanol (0,25 – 2000) mg/m3 (0,0050 – 10) mg in sample ethylbenzene (0,25 – 2000) mg/m3 (0,0050 – 10) mg in sample phenol (0,25 – 400) mg/m3 (0,0050 – 2) mg in sample benzyl butyl phthalate (0,25 – 400) mg/m3 (0,0050-2) mg in sample diethyl phthalate (0,25 – 400) mg/m3 (0,0050 – 2) mg in sample dibutyl phthalate (0,25 – 400) mg/m3 (0,0050 – 2) mg in sample dimethyl phthalate (0,25 – 400) mg/m3 (0,0050 – 2) mg in sample dioctyl phthalate (0,25 – 400) mg/m3 (0,0050-2) mg in sample bis(2-ethylhexyl) phthalate (0,25 – 400) mg/m3 (0,0050 – 2) mg in sample hexane (0,25 – 2000) mg/m3 (0,0050 – 10) mg in sample isobutanol (0,25 – 2000) mg/m3 (0,0050 – 10) mg in sample isopropanol (0,25 – 2000) mg/m3 (0,0050 – 10) mg in the sample xylene (0,25 – 2000) mg/m3 (0,0050 – 10) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-EN 13649:2005 | ||
| 37 | Waste gases | Concentration/content of individual gaseous organic compounds cumene (0,25 – 2000) mg/m3 Range (0,0050 – 10) mg in the sample acetic acid (0,25 – 400) mg/m3 (0,0050 – 10) mg in sample methyl methacrylate (0,25 – 2000) mg/m3 (0,0050 – 10) mg in sample methanol (0,25 – 2000) mg/m3 (0,0050 – 10) mg in sample methyl ethyl ketone (0,25 – 2000) mg/m3 (0,0050 – 10) mg in sample methyl isobutyl ketone (0,25 – 2000) mg/m3 (0,0050 – 10) mg in sample mesitylene (1,3,5-trimethylbenzene) (0,25 – 2000) mg/m3 (0,0050 – 10) mg in sample butyl acetate (0,25 – 2000) mg/m3 (0,0050 – 10) mg in sample ethyl acetate (0,25 – 2000) mg/m3 (0,0050 – 10) mg in sample methyl acetate (0,25 – 2000) mg/m3 (0,0050 – 10) mg in sample vinyl acetate (0,25 – 2000) mg/m3 (0,0050 – 10) mg in sample pentane (0,25 – 2000) mg/m3 (0,0050 – 10) mg in sample propylbenzene (0,25 – 2000) mg/m3 (0,0050 – 10) mg in sample styrene (0,25 – 2000) mg/m3 (0,0050 – 10) mg in sample toluene (0,25 – 2000) mg/m3 (0,0050 – 10) mg in sample aliphatic hydrocarbons (sum C5 - C12) (0,25 – 2000) mg/m3 (0,0050 – 10) mg in sample aromatic hydrocarbons (sum) (0,25 – 2000) mg/m3 (0,0050 – 10) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN 13649:2005 | |
| 38 | Waste gases | Emission of individual gaseous organic compounds (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-EN 13649:2005 | ||
| 39 | Waste gases | Concentration of sulphur dioxide, carbon monoxide, nitrogen monoxide, nitrogen dioxide, oxygen SO2 (3 – 2900) mg/m3 CO (2,5 – 6250) mg/m3 NO (1,4 – 4020) mg/m3 NO2 (4 – 990) mg/m3 O2 (2 – 21) % |
Electrochemical method | PN-ISO 10396:2001 | PB-03 edition 4 of 01.02.2023 | |
| 40 | Waste gases | Emission of SO2, CO, NO and NOx (calculated as NO2) (calculated) | PN-ISO 10396:2001 | PB-03 edition 4 of 01.02.2023 | ||
| 41 | Waste gases | Sampling for determination of the concentration of: ammonia chlorine, fluorine and fluorides, formaldehyde, isocyanates – MDI, TDI, sulfuric acid, hydrogen sulfide, hydrogen cyanide | Aspiration method using absorbing solutions | PB-16B edition 2 of 01.02.2023 | |
| 42 | Waste gases | Sampling for determination of the concentration of organosulfur compounds and methane | Isolation method using Tedlar bags | PB-61 edition 4 of 01.02.2023 | |
| 43 | Waste gases, Waste gas samples collected into absorbing solution | Ammonia concentration/content Range (0,5 – 800) mg/m3 (0,020 − 8) mg in the sample |
Spectrophotometric method | PB-11 edition 9 of 01.02.2023 | |
| 44 | Waste gases, Waste gas samples collected into absorbing solution | Ammonia emission (calculated) | PB-11 edition 9 of 01.02.2023 | ||
| 45 | Waste gases, Waste gas samples collected into absorbing solution | Sampling for determination of ammonia concentration | PN-EN ISO 21877:2020-03 | ||
| 46 | Waste gases, Waste gas samples collected into absorbing solution | Ammonia concentration/content Range (0,09 − 190) mg/m3 Range (0,01 – 11,25) mg in the sample |
Spectrophotometric method | PN-EN ISO 21877:2020-03 | |
| 47 | Waste gases, Waste gas samples collected into absorbing solution | Ammonia emission (calculated) | PN-EN ISO 21877:2020-03 | ||
| 48 | Waste gases, Waste gas samples collected into absorbing solution | Chlorine concentration/content Range (0,05 − 1) mg/m3 (0,002 − 0,014) mg in sample |
Spectrophotometric method | PB-13 edition 7 of 01.02.2023 | |
| 49 | Waste gases, Waste gas samples collected into absorbing solution | Chlorine emission (calculated) | PB-13 edition 7 of 01.02.2023 | ||
| 50 | Waste gases, Waste gas samples collected into absorbing solution | Sampling for determination of the concentration of fluorine and its compounds | ISO 15713:2006 | ||
| 51 | Waste gases, Waste gas samples collected into absorbing solution | Concentration/content of fluorine and its compounds Range (0,1 – 200) mg/m3 Range (0,010 – 50) mg in sample |
Potentiometric method | ISO 15713:2006 | |
| 52 | Waste gases, Waste gas samples collected into absorbing solution | Emission of fluorine and its compounds (calculated) | ISO 15713:2006 | ||
| 53 | Waste gases, Waste gas samples collected into absorbing solution | Concentration/content of fluorine and fluorides Range (0,1 − 8000) mg/m3 (0,0040 − 20) mg in sample |
Potentiometric method | PB-15 edition 6 of 01.02.2023 | |
| 54 | Waste gases, Waste gas samples collected into absorbing solution | Emission of fluorine and fluorides (calculated) | PB-15 edition 6 of 01.02.2023 | ||
| 55 | Waste gases, Waste gas samples collected into absorbing solution | Formaldehyde concentration/content Range (0,050 − 160) mg/m3 (0,0020 − 1,6) mg in the sample |
Spectrophotometric method | PB-06 edition 9 of 01.02.2023 | |
| 56 | Waste gases, Waste gas samples collected into absorbing solution | Formaldehyde emission (calculated) | PB-06 edition 9 of 01.02.2023 | ||
| 57 | Waste gases, Waste gas samples collected into absorbing solution | Concentration/content of isocyanates - MDI Range (0,156 − 250) mg/m3 (0,00625 − 2,5) mg in sample |
Spectrophotometric method | PB-09 edition 7 of 01.02.2023 | |
| 58 | Waste gases, Waste gas samples collected into absorbing solution | Emission of isocyanates - MDI (calculated) | PB-09 edition 7 of 01.02.2023 | ||
| 59 | Waste gases, Waste gas samples collected into absorbing solution | Concentration/content of isocyanates - TDI Range (0,10 − 320) mg/m3 (0,0040 − 3,2) mg in sample |
Spectrophotometric method | PB-10 edition 7 of 01.02.2023 | |
| 60 | Waste gases, Waste gas samples collected into absorbing solution | Emission of isocyanates - TDI (calculated) | PB-10 edition 7 of 01.02.2023 | ||
| 61 | Waste gases, Waste gas samples collected into absorbing solution | Sulfuric acid concentration/content Range (0,375 − 480) mg/m3 (0,015 − 4,9) mg in the sample |
Spectrophotometric method | PB-07 edition 6 of 01.02.2023 | |
| 62 | Waste gases, Waste gas samples collected into absorbing solution | Sulfuric acid emission (calculated) | PB-07 edition 6 of 01.02.2023 | ||
| 63 | Waste gases, Waste gas samples collected into absorbing solution | Hydrogen sulphide concentration/content Range (0,075 − 320) mg/m3 (0,0030 − 3,2) mg in the sample |
Spectrophotometric method | PB-58 edition 5 of 01.02.2023 | |
| 64 | Waste gases, Waste gas samples collected into absorbing solution | Hydrogen sulphide emission (calculated) | PB-58 edition 5 of 01.02.2023 | ||
| 65 | Waste gases, Waste gas samples collected into absorbing solution | Metal content: barium (0,0030 – 0,50) mg in the sample boron (0,0030 – 2,0) mg in the sample bismuth (0,015 – 2,0) mg in the sample tin (0,015 – 2,0) mg in the sample zinc (0,015 – 50) mg in the sample molybdenum(0,0030 – 2,0) mg in the sample selenium (0,015 – 1,0) mg in the sample titanium (0,015 – 2,0) mg in the sample iron (0,010 – 50) mg in the sample |
Inductively coupled plasma optical emission spectrometry (ICP-OES) | PN-EN 14385:2005 | |
| 66 | Waste gases, Waste gas samples collected on filters | Dust sampling for determination of metal concentrations in dust (Cr, Zn, Cd, Co, Mg, Mn, Cu, Ni, Pb, K, Ag, Fe, Sn, As, Cr, V, Bi, B, Ba, Mo, Se, Ti), Sampling for determination of metal concentrations (Zn, Mg, K, Ag, Fe, Sn, Bi, B, Ba, Mo, Se, Ti) | PN-Z-04030-7:1994 | PN-EN 14385:2005 | ||
| 67 | Waste gases, Waste gas samples collected on filters | Metal concentrations/contents: boron (0,00030 – 20) mg/m3 Range (0,0030 – 2,0) mg in the sample barium (0,00030 – 5,0) mg/m3 (0,0030 – 0,50) mg in sample bismuth (0,0015 – 20) mg/m3 (0,015 – 2,0) mg in the sample tin (0,0015 – 20) mg mg/m3 (0,015 – 2,0) mg in sample zinc (0,0015 – 500) mg/m3 (0,015 – 50) mg in the sample molybdenum (0,000030 – 20) mg/m3 (0,00030 – 2,0) mg in the sample selenium (0,0015 – 10) mg/m3 (0,015 – 1,0) mg in the sample titanium (0,0015 – 20) mg/m3 (0,015 – 2,0) mg in the sample iron (0,0010 – 500) mg/m3 (0,010 – 50) mg in sample |
Inductively coupled plasma optical emission spectrometry (ICP-OES) | PN-Z-04030-7:1994 | PN-EN 14385:2005 | |
| 68 | Waste gases, Waste gas samples collected on filters | Emission of metals (B, Ba, Bi, Sn, Zn, Mo, Se, Ti, Fe) (calculated) | PN-Z-04030-7:1994 | PN-EN 14385:2005 | ||
| 69 | Landfill gases | Concentration of methane, carbon dioxide, oxygen CH4 (0,5 – 70) % CO2 (0,5 – 60) % O2 (0,5 – 25) % |
Infrared spectrophotometry method; Electrochemical method | PB-14 edition 4 of 01.02.2023 | |
| 70 | Landfill gases | Velocity Range (0,5 – 10) m/s |
Anemometric method | PB-14 edition 4 of 01.02.2023 | |
| 71 | Landfill gases | Emission of methane, carbon dioxide (calculated) | PB-14 edition 4 of 01.02.2023 | ||
| 72 | General environment − ambient air | Carbon monoxide (CO) concentration Range (2,5 – 500) mg/m3 |
Non-dispersive infrared spectrometry (NDIR) | PB-02 edition 6 of 17.03.2025 | |
| 73 | General environment − ambient air | Volatile organic compounds (VOC) concentration expressed as total organic carbon (TOC) Range (1 – 100) mg/m3 |
Continuous flame ionization detection method (FID) | PB-30 edition 6 of 17.03.2025 | |
| 74 | General environment − ambient air | Dust sampling for testing | PB-01 edition 6 of 21.02.2025 | ||
| 75 | General environment − ambient air | Dust concentration Range (0,0055 – 10) mg/m3 |
Gravimetric method | PB-01 edition 6 of 21.02.2025 | |
| 76 | General environment − ambient air | Sampling for determination of the concentration of: ammonia, chlorine, hydrogen chloride, fluorine and its compounds, formaldehyde, isocyanates – MDI, TDI, sulfuric acid, hydrogen sulfide | Aspiration method using absorbing solutions | PB-16A edition 2 of 01.02.2023 | |
| 77 | General environment − ambient air | Sampling for the determination of organic compound concentration | Aspiration method using activated carbon, silica gel, chromosorb, XAD-2 | PB-16A edition 2 of 01.02.2023 | |
| 78 | General environment − ambient air | Sampling for determination of the concentration of organosulfur compounds and methane | Isolation method using Tedlar bags | PB-61 edition 4 of 01.02.2023 | |
| 79 | General environment − ambient air | Sampling of suspended particulate matter, PM10 or PM2,5 | Aspiration method | PN-EN 12341:2014 excluding cl. 5.2, 6.2, 6.4, 6.5 | |
| 80 | General environment − ambient air | Sampling of PM10 and PM2,5 dust for determination of metal concentrations: As, Ba, B, Bi, Cd, Cr, Co, Cu, Fe, Mn, Mo, Ni, Pb, Sb, Sn, Ti, V, Zn | Aspiration method | PN-EN 12341:2014 excluding cl. 5.2, 6.2, 6.4, 6.5 | |
| 81 | General environment − ambient air – ambient air samples collected into absorbing solution | Ammonia concentration/content Range (0,25 − 400) mg/m3 (0,010 − 8) mg in the sample |
Spectrophotometric method | PB-11 edition 9 of 01.02.2023 | |
| 82 | General environment − ambient air – ambient air samples collected into absorbing solution | Chlorine concentration/content Range (0,05 – 0,5) mg/m3 (0,002 − 0,014) mg in sample |
Spectrophotometric method | PB-13 edition 7 of 01.02.2023 | |
| 83 | General environment − ambient air – ambient air samples collected into absorbing solution | Hydrogen chloride concentration/content Range (0,5 - 10) mg/m3 Range (0,02 – 4,0) mg in the sample |
Spectrophotometric method | PB-12 edition 6 of 01.02.2023 | |
| 84 | General environment − ambient air – ambient air samples collected into absorbing solution | Concentration/content of fluorine and its compounds Range (0,1 − 4000) mg/m3 (0,0040 − 20) mg in sample |
Potentiometric method | PB-15 edition 6 of 01.02.2023 | |
| 85 | General environment − ambient air – ambient air samples collected into absorbing solution | Formaldehyde concentration/content Range (0,025 − 40) mg/m3 (0,0010 − 0,8) mg in the sample |
Spectrophotometric method | PB-06 edition 9 of 01.02.2023 | |
| 86 | General environment − ambient air – ambient air samples collected into absorbing solution | Concentration/content of isocyanates - MDI Range (0,156 − 125) mg/m3 (0,00625 − 2,5) mg in sample |
Spectrophotometric method | PB-09 edition 7 of 01.02.2023 | |
| 87 | General environment − ambient air – ambient air samples collected into absorbing solution | Concentration/content of isocyanates - TDI Range (0,100 − 250) mg/m3 (0,0040 − 3,2) mg in sample |
Spectrophotometric method | PB-10 edition 7 of 01.02.2023 | |
| 88 | General environment − ambient air – ambient air samples collected into absorbing solution | Sulfuric acid concentration/content Range (0,375 − 120) mg/m3 Range (0,015 – 2,45) mg in the sample |
Spectrophotometric method | PB-07 edition 6 of 01.02.2023 | |
| 89 | General environment − ambient air – ambient air samples collected into absorbing solution | Hydrogen sulphide concentration/content Range (0,019 − 0,5) mg/m3 (0,0015 − 0,010) mg in the sample |
Spectrophotometric method | PB-58 edition 5 of 01.02.2023 | |
| 90 | General environment − ambient air – ambient air samples collected into absorbing solution | Sampling for determination of NO2 concentration | PN-Z-04009-9:1997 | ||
| 91 | General environment − ambient air – ambient air samples collected into absorbing solution | NO2 concentration/content Range (12,6 – 6285) μg/m3 Range (0,40 – 200) μg in the sample |
Spectrophotometric method | PN-Z-04009-9:1997 | |
| 92 | General environment − ambient air – ambient air samples collected into absorbing solution | Sampling for determination of SO2 concentration | PN-ISO 6767:1997 | ||
| 93 | General environment − ambient air – ambient air samples collected into absorbing solution | SO2 concentration/content Range (26,7 – 853) μg/m3 Range (1,6 – 25,6) μg in the sample |
Spectrophotometric method | PN-ISO 6767:1997 | |
| 94 | General environment − ambient air − ambient air samples collected on sorbent tubes | Concentration/content of organic compounds Range 1,2,4-trimethylbenzene Range (0,00260 – 125) mg/m3 Range (0,0050 – 10) mg in the sample acetone (0,00260 – 125) mg/m3 (0,0050 – 10) mg in sample acrolein (0,00260 – 25) mg/m3 (0,0050 – 2) mg in sample diacetone alcohol (0,00260 – 125) mg/m3 (0,0050 – 10) mg in sample benzene (0,00260 – 125) mg/m3 (0,0050 – 10) mg in sample butanol (0,00260 – 125) mg/m3 (0,0050 – 10) mg in sample butyl glycol (0,00260 – 25) mg/m3 (0,0050 – 20) mg in sample methylene chloride (0,00260 – 125) mg/m3 (0,0050 – 10) mg in sample cyclohexane (0,00260 – 125) mg/m3 (0,0050 – 10) mg in sample cyclohexanol (0,00260 – 125) mg/m3 (0,0050 – 10) mg in the sample Cyclohexanone (0,00260 – 125) mg/m3 (0,0050 – 10) mg in sample epichlorohydrin (0,00260 – 125) mg/m3 (0,0050 – 10) mg in sample ethanol (0,00260 – 125) mg/m3 (0,0050 – 10) mg in sample ethylbenzene (0,00260 – 125) mg/m3 (0,0050 – 10) mg in sample phenol (0,00260 – 25) mg/m3 (0,0050 – 2) mg in sample benzyl butyl phthalate (0,00260 – 25) mg/m3 (0,0050-2) mg in sample diethyl phthalate (0,00260 – 25) mg/m3 (0,0050 – 2) mg in sample dibutyl phthalate (0,00260 – 25) mg/m3 (0,0050 – 2) mg in sample dimethyl phthalate (0,00260 – 25) mg/m3 (0,0050 – 2) mg in sample dioctyl phthalate (0,00260 – 25) mg/m3 (0,0050-2) mg in sample bis(2-ethylhexyl) phthalate (0,00260 – 25) mg/m3 (0,0050 – 2) mg in sample hexane (0,00260 – 125) mg/m3 (0,0050 – 10) mg in sample isobutanol (0,00260 – 125) mg/m3 (0,0050 – 10) mg in sample isopropanol (0,00260 – 125) mg/m3 (0,0050 – 10) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PB-05 edition 12 of 01.02.2023 | |
| 95 | General environment − ambient air − ambient air samples collected on sorbent tubes | Concentration/content of organic compounds xylene (0,00260 – 125) mg/m3 Range (0,0050 – 10) mg in the sample cumene (0,00260 – 125) mg/m3 (0,0050 – 10) mg in the sample acetic acid (0,00260 – 125) mg/m3 (0,0050 – 10) mg in sample methyl methacrylate (0,00260 – 125) mg/m3 (0,0050 – 10) mg in sample methanol (0,00260 – 125) mg/m3 (0,0050 – 10) mg in sample methyl ethyl ketone (0,00260 – 125) mg/m3 (0,0050 – 10) mg in sample methyl isobutyl ketone (0,00260 – 125) mg/m3 (0,0050 – 10) mg in sample mesitylene (0,00260 – 125) mg/m3 (0,0050 – 10) mg in sample butyl acetate (0,00260 – 125) mg/m3 (0,0050 – 10) mg in sample ethyl acetate (0,00260 – 125) mg/m3 (0,0050 – 10) mg in sample methyl acetate (0,00260 – 125) mg/m3 (0,0050 – 10) mg in sample vinyl acetate (0,00260 – 125) mg/m3 (0,0050 – 10) mg in sample pentane (0,00260 – 125) mg/m3 (0,0050 – 10) mg in sample propylbenzene (0,00260 – 125) mg/m3 (0,0050 – 10) mg in sample styrene (0,00260 – 125) mg/m3 (0,0050 – 10) mg in sample toluene (0,00260 – 125) mg/m3 (0,0050 – 10) mg in sample aliphatic hydrocarbons (sum C5 - C12) (0,00260 – 125) mg/m3 (0,0050 – 10) mg in sample aromatic hydrocarbons (sum) (0,00260 – 125) mg/m3 (0,0050 – 10) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PB-05 edition 12 of 01.02.2023 | |
| 96 | General environment – ambient air – ambient air samples collected on filters | Concentration / content of metals antimony (0,00030 – 0,56) mg/m3 Range (0,0030 – 2,0) mg in the sample arsenic (0,000015 – 0,56) mg/m3 (0,00015 – 2,0) mg in the sample boron (0,00030 – 0,56) mg/m3 (0,0030 – 2,0) mg in the sample barium (0,00030 – 0,14) mg/m3 (0,0030 – 0,50) mg in sample bismuth (0,00150 – 0,56) mg/m3 (0,015 – 2,0) mg in the sample chromium (0,00030 – 47,2) mg/m3 (0,0030 – 170) mg in the sample tin (0,00150 – 0,56) mg/m3 (0,015 – 2,0) mg in sample zinc (0,00150 – 13,9) mg/m3 (0,015 – 50) mg in the sample cadmium (0,000015 – 0,28) mg/m3 (0,00015 – 1,0) mg in sample cobalt (0,000015 – 0,56) mg/m3 (0,00015 – 2,0) mg in sample manganese (0,00030 – 0,56) mg/m3 (0,0030 – 2,0) mg in sample copper (0,00030 – 0,97) mg/m3 (0,0030 – 3,50) mg in the sample molybdenum (0,000030 – 0,56) mg/m3 (0,00030 – 2,0) mg in the sample nickel (0,00030 – 4,2) mg/m3 (0,0030 – 150) mg in the sample lead (0,00030 – 13,9) mg/m3 (0,0030 – 50) mg in the sample titanium (0,00150 – 0,56) mg/m3 (0,015 – 2,0) mg in the sample vanadium (0,000015 – 0,56) mg/m3 (0,00015 – 2,0) mg in the sample iron (0,0010 – 13,9) mg/m3 (0,010 – 50) mg in sample |
Inductively coupled plasma optical emission spectrometry (ICP-OES) | PB-60 edition 3 of 01.02.2023 | |
| 97 | General environment – ambient air – ambient air samples collected on filters – ambient air samples collected into absorbing solution | Metal content: antimony (0,0030 – 2,0) mg in the sample arsenic (0,00030 – 2,0) mg in the sample barium (0,0030 – 0,50) mg in the sample boron (0,0030 – 2,0) mg in the sample bismuth (0,015 – 2,0) mg in the sample tin (0,015 – 2,0) mg in the sample zinc (0,015 – 50) mg in the sample chromium (0,0030 – 170) mg in the sample cadmium (0,00015 – 1,0) mg in the sample cobalt (0,00015 – 2,0) mg in the sample manganese (0,0030 – 2,0) mg in the sample copper (0,0030 – 3,5) mg in the sample molybdenum(0,0030 – 2,0) mg in the sample nickel (0,0030 – 15) mg in the sample lead (0,0030 – 50) mg in the sample selenium (0,015 – 1,0) mg in the sample vanadium (0,00015 – 2,0) mg in the sample titanium (0,015 – 2,0) mg in the sample iron (0,010 – 50) mg in the sample |
Inductively coupled plasma optical emission spectrometry (ICP-OES) | PN-EN 14385:2005 | |
| 98 | Rainwater and snowmelt water | Sampling for chemical and physical testing Temperature of the water sample taken Range (0,0 – 50,0) oC |
PN-ISO 5667-10:1997 | PB-32 edition 4 of 01.02.2023 | ||
| 99 | Rainwater and snowmelt water | Mineral oil index C10 – C40 (petroleum hydrocarbons) Range (0,60 – 50) mg/l |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN ISO 9377-2:2003 | |
| 100 | Rainwater and snowmelt water | Total suspended solids (TSS) Range (2,0 – 1000) mg/l |
Gravimetric method | PN-EN 872:2007+Ap1:2007 | |
| 101 | General environment − noise from installations, equipment and industrial plants | A-weighted equivalent sound pressure level Range (25 – 137) dB |
Direct measurement method | Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023, item 1706) | |
| 102 | General environment − noise from installations, equipment and industrial plants | A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) | Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023, item 1706) | ||
| 103 | General environment − noise from installations, equipment and industrial plants | Calculation method | PN-ISO 9613-2:2002 CNOSSOS-EU (Industry) | ||
| 104 | General environment − impulse noise from installations and equipment | A-weighted equivalent sound level A-weighted sound exposure level Range (25 – 137) dB |
Direct measurement method | Annex 8 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023, item 1706) | PN-ISO 1996-2:1999+A1:2002 | |
| 105 | General environment − impulse noise from installations and equipment | A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) | Annex 8 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023, item 1706) | PN-ISO 1996-2:1999+A1:2002 | ||
| 106 | Machinery and equipment − noise | A-weighted equivalent sound pressure level Range (25 – 137) dB |
Direct measurement method | PN-EN ISO 3746:2011+Ap1:2017-09 | |
| 107 | Machinery and equipment − noise | Sound power level, Sound energy level (calculated) | PN-EN ISO 3746:2011+Ap1:2017-09 | ||
| 108 | General environment – noise barriers „in situ” | A-weighted equivalent sound pressure level Range (25 − 137) dB |
Direct measurement method | PN-ISO 10847:2002 | |
| 109 | General environment – noise barriers „in situ” | Effectiveness of screens (calculated) | PN-ISO 10847:2002 | ||
| 110 | General environment − noise from roads, railway lines, tram lines | A-weighted equivalent sound level A-weighted sound exposure level Range (25 – 137) dB |
Direct measurement method | Annex 3 to the Regulation of the Minister of the Environment of 16.06.2011 (Journal of Laws No. 140, item 824 and No. 288, item 1697) | |
| 111 | General environment − noise from roads, railway lines, tram lines | A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) | Annex 3 to the Regulation of the Minister of the Environment of 16.06.2011 (Journal of Laws No. 140, item 824 and No. 288, item 1697) | ||
| 112 | General environment − noise from roads, railway lines, tram lines | Calculation method | NMBP-Roads-1996/NFS 31-133 (XPS 31-133) NMPB-Roads-2008 CNOSSOS-EU (Road) RMR/SRM II CNOSSOS-EU (Rail) | ||
| 113 | General environment − noise from airports | A-weighted equivalent sound level A-weighted sound exposure level Range (25 −137) dB |
Direct measurement method | Annexes 1 and 2 to the Regulation of the Minister of the Environment of 16.06.2011 (Journal of Laws 2011 No. 140, item 824) | |
| 114 | General environment − noise from airports | A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) | Annexes 1 and 2 to the Regulation of the Minister of the Environment of 16.06.2011 (Journal of Laws 2011 No. 140, item 824) | ||
Reference standards (51)
ISO 12039:2019
ISO 15713:2006
NMBP-Roads-1996/NFS 31-133 (XPS 31-133) NMPB-Roads-2008 CNOSSOS-EU (Road) RMR/SRM II CNOSSOS-EU (Rail)
PB-01 edition 6 of 21.02.2025
PB-02 edition 6 of 17.03.2025
PB-03 edition 4 of 01.02.2023
PB-05 edition 12 of 01.02.2023
PB-06 edition 9 of 01.02.2023
PB-07 edition 6 of 01.02.2023
PB-09 edition 7 of 01.02.2023
PB-10 edition 7 of 01.02.2023
PB-11 edition 9 of 01.02.2023
PB-12 edition 6 of 01.02.2023
PB-13 edition 7 of 01.02.2023
PB-14 edition 4 of 01.02.2023
PB-15 edition 6 of 01.02.2023
PB-16A edition 2 of 01.02.2023
PB-16B edition 2 of 01.02.2023
PB-30 edition 6 of 17.03.2025
PB-32 edition 4 of 01.02.2023
PB-58 edition 5 of 01.02.2023
PB-60 edition 3 of 01.02.2023
PB-61 edition 4 of 01.02.2023
PN-EN 12341:2014 excluding cl. 5.2, 6.2, 6.4, 6.5
PN-EN 12619:2013
PN-EN 13211+AC:2006
PN-EN 13284-1:2018-02
PN-EN 13649:2005
PN-EN 14385:2005
PN-EN 14789:2017-04
PN-EN 14790:2017-04
PN-EN 14791:2017-4
PN-EN 14792:2017-04
PN-EN 15058:2017-04
PN-EN 1911:2011
PN-EN 872:2007+Ap1:2007
PN-EN ISO 21877:2020-03
PN-EN ISO 3746:2011+Ap1:2017-09
PN-EN ISO 9377-2:2003
PN-ISO 10396:2001
PN-ISO 10847:2002
PN-ISO 1996-2:1999+A1:2002
PN-ISO 5667-10:1997
PN-ISO 6767:1997
PN-ISO 9613-2:2002 CNOSSOS-EU (Industry)
PN-Z-04009-9:1997
PN-Z-04030-7:1994
Annexes 1 and 2 to the Regulation of the Minister of the Environment of 16.06.2011 (Journal of Laws 2011 No. 140, item 824)
Annex 3 to the Regulation of the Minister of the Environment of 16.06.2011 (Journal of Laws No. 140, item 824 and No. 288, item 1697)
Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023, item 1706)
Annex 8 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023, item 1706)