🇵🇱 MILAB Czesław Misiun PL

PCA AB 900 • Koszalin, Poland • 24 methods

EnvironmentConstruction

MILAB Czesław Misiun is a laboratory accredited by PCA under number AB 900 (Koszalin, Poland). Its accreditation scope covers 24 test methods in the following areas: Environment, Construction. Test objects include: Workplace environment − air, Workplace environment - emergency lighting, General environment − noise from machines, equipment, installations…, Workplace environment - electromagnetic field from power systems an…. Most frequently used techniques: Direct measurement method, Gravimetric method, Direct measurement method (simplified).

At a glance

  • Accreditation number: PCA AB 900
  • Methods in scope: 24
  • Types of test objects: 11
  • Techniques used: 4
  • City: Koszalin, Poland
Accreditation number
AB 900
Accreditation body
PCA
Address
ul. Westerplatte 23, 75-642 Koszalin
City
Koszalin, Poland

What this laboratory tests (11)

Analytical techniques used (4)

Laboratory locations

Certificate information

Issue date
23.04.2026
Issue no.
19

Accreditation scope — test methods (24)

No. Test object Methodology / Parameters Technique Reference document
Laboratory, ul. Westerplatte 23, 75-642 Koszalin
1 Workplace environment − noise A-weighted equivalent sound level A-weighted maximum sound level C-weighted peak sound level Sound pressure level in octave bands (63 - 8000) Hz
A-weighted equivalent sound pressure level (35,0 – 135,0) dB Maximum A-weighted sound pressure level (35,0 – 135,0) dB C-weighted peak sound pressure level (35,0 – 137,0) dB Sound pressure level in octave bands (63 - 8000) Hz (25,0 – 135,0) dB
Direct measurement method PN-N-01307:1994 | PN-EN ISO 9612:2011 excluding the method covering strategy 2 - cl. 10 and strategy 3 - cl. 11
2 Workplace environment − noise Noise exposure level normalised to: − an 8-hour working day − an average weekly working time (calculated) PN-N-01307:1994 | PN-EN ISO 9612:2011 excluding the method covering strategy 2 - cl. 10 and strategy 3 - cl. 11
3 General environment − noise from machines, equipment, installations, industrial plants A-weighted equivalent sound pressure level
Range (24,0 – 90,0) dB
Direct measurement method Annex 7 to the Regulation of the Minister of Climate and Environment of 7.09.2021 (consolidated text Journal of Laws of 2023 item 1706) excluding cl. F
4 General environment − noise from machines, equipment, installations, industrial plants A-weighted equivalent sound level for reference time T (calculated) Annex 7 to the Regulation of the Minister of Climate and Environment of 7.09.2021 (consolidated text Journal of Laws of 2023 item 1706) excluding cl. F
5 Workplace environment − air Air sampling for the assessment of occupational exposure to:
− dust agents - inhalable fraction - respirable fraction − organic substances, including - inhalable fraction − inorganic substances - respirable fraction − metals and their compounds, including - inhalable fraction - respirable fraction
Personal dosimetry method PN-Z-04008-7:2002+Az1:2004
6 Workplace environment − air Exposure index (calculated) PN-Z-04008-7:2002+Az1:2004
7 Workplace environment − air Concentration of harmful dust agents – inhalable fraction:
Apatites and phosphorites Petroleum bitumen Portland cement Titanium dioxide Natural graphite Synthetic graphite Kaolin Amorphous and synthetic silica Wood dusts Flour dusts Dusts not classified according to toxicity Organic dusts of animal and plant origin, excluding wood and flour dusts Carbon black Calcium sulfate (VI) (gypsum) Talc Coal (hard, brown) Calcium magnesium carbonate (dolomite) Silicon carbide, non-fibrous Range (0,10 – 17,0) mg/m3
Gravimetric method PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08
8 Workplace environment − air Concentration of harmful dust agents – respirable fraction:
Apatites and phosphorites Portland cement Natural graphite Amorphous and synthetic silica Organic dusts of animal and plant origin, excluding wood and flour dusts Talc Coal (hard, brown) Range (0,10 – 15,0) mg/m3
Gravimetric method PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08
9 Workplace environment − indoor electric lighting Illuminance
Range (0,5 – 10000) lx
Direct measurement method PN-83/E-04040.03
10 Workplace environment − indoor electric lighting Illuminance uniformity (calculated) PN-83/E-04040.03
11 Workplace environment - emergency lighting Illuminance
Range (0,5 – 100) lx
Direct measurement method PN-EN 1838:2013-11 cl. 4.2.1, cl. 4.2.2, cl. 4.2.5, cl. 4.2.6
12 Workplace environment - emergency lighting Ratio of minimum to maximum illuminance (calculated) PN-EN 1838:2013-11 cl. 4.2.1, cl. 4.2.2, cl. 4.2.5, cl. 4.2.6
13 Workplace environment - emergency lighting Closing time
Range (1 – 80) s
Direct measurement method PN-EN 1838:2013-11 cl. 4.2.1, cl. 4.2.2, cl. 4.2.5, cl. 4.2.6
14 Workplace environment − hand-arm vibration Frequency-corrected effective vibration acceleration
Range (0,5 – 30) m/s2
Direct measurement method PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11
15 Workplace environment − hand-arm vibration Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the vector sum of the r.m.s. frequency-corrected vibration accelerations determined for three directional components (ahwx, ahwy, ahwz), Exposure lasting 30 minutes or less, expressed as the vector sum of the r.m.s. frequency-weighted vibration accelerations determined for three directional components (ahwx, ahwy, ahwz) (calculated) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11
16 Workplace environment − whole-body vibration Frequency-weighted r.m.s. vibration acceleration
Range (0,07 – 35) m/s2
Direct measurement method PN-EN 14253+A1:2011
17 Workplace environment − whole-body vibration Daily exposure expressed as the energy-equivalent for 8 hours of the r.m.s., frequency-weighted vibration acceleration dominant among the vibration accelerations determined for the three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz)., Exposure lasting 30 min. and less expressed as the r.m.s., frequency-weighted vibration acceleration dominant among the vibration accelerations determined for the three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz) (calculated) PN-EN 14253+A1:2011
18 Workplace environment − electromagnetic field from industrial installations and equipment: - arc welding equipment - resistance welding machines - dielectric heating equipment - induction heating equipment - industrial furnaces, heaters, - electrical discharge machines Electric field strength:
in the frequency range from 10 Hz to 400 kHz (1 – 50 000) V/m in the frequency range from 0,1 MHz to 300 MHz (1,4 − 1100) V/m
Regulated area: Method adapted to the regulated area
Direct measurement method PN-T-06580-3:2002 | IR 18 issue 1 of 22.04.2026 | IR 18A issue 1 of 22.04.2026 | IR 18D issue 1 of 22.04.2026 | IR 18E issue 1 of 22.04.2026
19 Workplace environment − electromagnetic field from industrial installations and equipment: - arc welding equipment - resistance welding machines - dielectric heating equipment - induction heating equipment - industrial furnaces, heaters, - electrical discharge machines Magnetic field strength:
in the frequency range from 10 Hz to 400 kHz (0,8 – 15 800) A/m in the frequency range from 0,2 MHz to 2 MHz (0,03 – 14,2) A/m in the frequency range from 10 MHz to 40 MHz (0,012 − 5) A/m
Regulated area: Method adapted to the regulated area
Direct measurement method PN-T-06580-3:2002 | IR 18 issue 1 of 22.04.2026 | IR 18A issue 1 of 22.04.2026 | IR 18D issue 1 of 22.04.2026 | IR 18E issue 1 of 22.04.2026
20 Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy units - physiotherapy diathermy units Electric field strength:
in the frequency range from 0,1 MHz to 300 MHz (1,4 − 1100) V/m
Regulated area: Method adapted to the regulated area
Direct measurement method PN-T-06580-3:2002 | IR 18 issue 1 of 22.04.2026 | IR 18B issue 1 of 22.04.2026 | IR 18C issue 1 of 22.04.2026
21 Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy units - physiotherapy diathermy units Magnetic field strength:
in the frequency range from 0,2 MHz to 2 MHz (0,03 – 14,2) A/m in the frequency range from 10 MHz to 40 MHz (0,012 − 5) A/m
Regulated area: Method adapted to the regulated area
Direct measurement method PN-T-06580-3:2002 | IR 18 issue 1 of 22.04.2026 | IR 18B issue 1 of 22.04.2026 | IR 18C issue 1 of 22.04.2026
22 Workplace environment - electromagnetic field from power systems and AC electrical supply installations in the power industry Electric field strength:
in the frequency range from 10 Hz to 400 kHz (1 – 50 000) V/m
Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (consolidated text: Journal of Laws of 2018, item 331).
Direct measurement method Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 91–150
23 Workplace environment - electromagnetic field from power systems and AC electrical supply installations in the power industry Magnetic field strength:
in the frequency range from 10 Hz to 400 kHz (0,8 – 15 800) A/m
Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (consolidated text: Journal of Laws of 2018, item 331).
Direct measurement method Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 91–150
24 Workplace environment - electromagnetic field in the workspace from magnetotherapy devices Magnetic field strength:
in the frequency range from 10 Hz to 400 Hz (0,8 – 15 800) A/m
Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (consolidated text: Journal of Laws of 2018, item 331).
Direct measurement method (simplified) Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 151–180

Reference standards (23)

IR 18 issue 1 of 22.04.2026
IR 18A issue 1 of 22.04.2026
IR 18B issue 1 of 22.04.2026
IR 18C issue 1 of 22.04.2026
IR 18D issue 1 of 22.04.2026
IR 18E issue 1 of 22.04.2026
PN-83/E-04040.03
PN-EN 14253+A1:2011
PN-EN 1838:2013-11 cl. 4.2.1, cl. 4.2.2, cl. 4.2.5, cl. 4.2.6
PN-EN ISO 5349-1:2004
PN-EN ISO 5349-2:2004
PN-EN ISO 5349-2:2004/A1:2015-11
PN-EN ISO 9612:2011 excluding the method covering strategy 2 - cl. 10 and strategy 3 - cl. 11
PN-N-01307:1994
PN-T-06580-3:2002
PN-Z-04008-7:2002+Az1:2004
PN-Z-04507:2022-05
PN-Z-04507:2022-05/Ap1:2022-08
PN-Z-04508:2022-05
PN-Z-04508:2022-05/Ap1:2022-08
Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 151–180
Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 91–150
Annex 7 to the Regulation of the Minister of Climate and Environment of 7.09.2021 (consolidated text Journal of Laws of 2023 item 1706) excluding cl. F

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/PL/AB%20900