🇵🇱 LABORATORIUM BADAŃ I POMIARÓW ŚRODOWISKA PL

PCA AB 875 • Łódź, Poland • 215 methods

Environment

LABORATORIUM BADAŃ I POMIARÓW ŚRODOWISKA is a laboratory accredited by PCA under number AB 875 (Łódź, Poland). Its accreditation scope covers 215 test methods in the following areas: Environment. Test objects include: Waste gases, Workplace environment - air - air samples collected on sorbent tubes, Workplace environment - air - air samples collected on a filter, Workplace environment - air - air samples collected into absorbing…. Most frequently used techniques: Gas chromatography with flame ionization detection (GC-FID), Spectrophotometric method, Flame atomic absorption spectrometry (FAAS).

At a glance

  • Accreditation number: PCA AB 875
  • Methods in scope: 215
  • Types of test objects: 20
  • Techniques used: 22
  • City: Łódź, Poland
Accreditation number
AB 875
Accreditation body
PCA
Address
EKOLAB Spółka Cywilna, Janusz Michalak, Grażyna Felisiak, Anna Wysocka, ul. Dzika 27A, 91-459 Łódź
City
Łódź, Poland

What this laboratory tests (20)

Analytical techniques used (22)

Certificate information

Issue date
29.01.2026
Issue no.
22

Accreditation scope — test methods (215)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Workplace environment - air Sampling for the assessment of occupational exposure to
dust agents – inhalable fraction – respirable fraction organic substances, including – inhalable fraction inorganic substances, including – inhalable fraction – respirable fraction metals and their compounds, including – inhalable fraction – respirable fraction
Stationary method; Personal dosimetry method PN-Z-04008-7:2002+Az1:2004
2 Workplace environment - air Exposure index (calculated) PN-Z-04008-7:2002+Az1:2004
3 Workplace environment - air Carbon monoxide concentration
Range (2 - 200) mg/m3 Range (2 – 172) ppm
Electrochemical method Test procedure PB 398 issue 2 of 02.05.2013
4 Workplace environment - air Exposure indices (calculated) Test procedure PB 398 issue 2 of 02.05.2013
5 Workplace environment - air Concentration of harmful dust agents
inhalable fraction – petroleum bitumen – apatites and phosphorites – Portland cement – titanium dioxide – natural graphite – synthetic graphite – kaolin – amorphous and synthetic silica – wood dusts – flour dusts – dusts not classified according to toxicity – organic dusts of animal and plant origin excluding wood and flour dusts – calcium sulphate(VI) (gypsum) – carbon black – talc – coal (hard, brown) – calcium magnesium carbonate (dolomite) – silicon carbide, non-fibrous Range (0,17-20,45) mg/m3
Gravimetric method PN-Z-04507:2022-05 | PN-Z-04507:2022-05+Ap1:2022-08
6 Workplace environment - air Concentration of harmful dust agents
respirable fraction – apatites and phosphorites – Portland cement – natural graphite – amorphous and synthetic silica – organic dusts of animal and plant origin excluding wood and flour dusts – talc – coal (hard, brown) Range (0,09-15,43) mg/m3
Gravimetric method PN-Z-04508:2022-05 | PN-Z-04508:2022-05+Ap1:2022-08
7 Workplace environment - air Concentration/content of crystalline silica (quartz, cristobalite)
respirable fraction Range (0,008 – 0,56) mg/m3 Range (0,005 – 0,4) mg in the sample
Fourier transform infrared spectrometry (FT-IR) Principles and Methods of Assessing the Working Environment 2012, No. 4 (74), pp. 117–130
8 Workplace environment - air - air samples collected into absorbing solution Concentration/content of acrylaldehyde
Range (0,013 - 8,0) mg/m3 Range (0.0056 – 3,44) ppm Range (0,0001 - 0,0060) mg in the sample
Spectrophotometric method Test procedure PB 006 issue 4 of 02.05.2013
9 Workplace environment - air - air samples collected into absorbing solution Ammonia concentration/content
Range (1 - 100) mg/m3 Range (0,01 - 0,2) mg in the sample
Spectrophotometric method PN-71/Z-04041
10 Workplace environment - air - air samples collected into absorbing solution Chlorine concentration/content
Range (0,055 - 10) mg/m3 Range (0,0004 - 0,05) mg in the sample
Spectrophotometric method PN-75/Z-04037.03
11 Workplace environment - air - air samples collected into absorbing solution Hydrogen chloride concentration/content
Range (0,33 - 50) mg/m3 Range (0,005 - 0,2) mg in the sample
Spectrophotometric method Test procedure PB 089 issue 2 of 02.05.2013
12 Workplace environment - air - air samples collected into absorbing solution Concentration/content of tetraphosphorus decaoxide
Range (0,067 - 10) mg/m3 Range (0,001 - 0,02) mg in the sample
Spectrophotometric method PN-Z-04073-1:2014-08
13 Workplace environment - air - air samples collected into absorbing solution Nitrogen dioxide concentration/content
Range (0,067 - 10,7) mg/m3 Range (0,035 – 5,61) ppm Range (0,00025 - 0,040) mg in the sample
Spectrophotometric method PN-Z-04009-11:2008
14 Workplace environment - air - air samples collected into absorbing solution Hydrogen peroxide concentration/content
Range (0,025 – 5,0) mg/m3 Range (0,0005 - 0,10) mg in the sample
Spectrophotometric method Test procedure PB 299 issue 5 of 02.05.2023
15 Workplace environment - air - air samples collected into absorbing solution Sulphur dioxide concentration/content
Range (0,07 - 12) mg/m3 Range (0,026 – 4,52) ppm Range (0,001 - 0,02) mg in the sample
Spectrophotometric method PN-Z-04015-12:1996
16 Workplace environment - air - air samples collected into absorbing solution Formaldehyde concentration/content
Range (0,013 - 3,2) mg/m3 Range (0,0001 - 0,004) mg in the sample
Spectrophotometric method Test procedure PB 196 issue 4 of 02.05.2013
17 Workplace environment - air - air samples collected into absorbing solution Phosphoric(V) acid concentration/content
Range (0,092 - 15) mg/m3 Range (0,0014 - 0,028) mg in the sample
Spectrophotometric method PN-Z-04073-1:2014-08
18 Workplace environment - air - air samples collected into absorbing solution Formic acid concentration/content
Range (0,33 - 40) mg/m3 Range (0,0025 - 0,075) mg in the sample
Spectrophotometric method PN-88/Z-04196.02
19 Workplace environment - air - air samples collected into absorbing solution Ozone concentration/content
Range (0,013 – 10) mg/m3 Range (0,0002 – 0,005) mg in the sample
Spectrophotometric method Test procedure PB 341 issue 5 of 02.05.2013
20 Workplace environment - air - air samples collected into absorbing solution Hydrogen sulphide concentration/content
Range (0,67 - 33,3) mg/m3 Range (0,005 - 0,050) mg in the sample
Spectrophotometric method PN-Z-04015-13:1996
21 Workplace environment - air - air samples collected into absorbing solution Nitrogen monoxide concentration/content
Range (0,044 - 7,0) mg/m3 Range (0,035 – 5,62) ppm Range (0,00016 - 0,026) mg in the sample
Spectrophotometric method PN-Z-04009-11:2008
22 Workplace environment - air - air samples collected into absorbing solution Concentration/content of hydrogen cyanide and cyanides – calculated as CN (hydrogen cyanide)
Range (0,063 - 12,5) mg/m3 Range (0,056 – 11,16) ppm Range (0,0005 - 0,05) mg in the sample
Potentiometric method Test procedure PB 094A issue 3 of 02.05.2013
23 Workplace environment - air - air samples collected into absorbing solution Concentration/content:
hydrogen fluoride fluorides expressed as F- Range (0,033 - 13,3) mg/m3 Range (0,001 - 0,1) mg in the sample
Potentiometric method Test procedure PB 192 issue 5 of 02.05.2013
24 Workplace environment - air - air samples collected into absorbing solution Potassium hydroxide concentration/content
Range (0,05 - 9,5) mg/m3 Range (0,0007 - 0,014) mg in the sample
Flame atomic absorption spectrometry (FAAS) PN-87/Z-04005.05
25 Workplace environment - air - air samples collected into absorbing solution Sodium hydroxide concentration/content
Range (0,06 - 11,6) mg/m3 Range (0,0009 - 0,018) mg in the sample
Flame atomic absorption spectrometry (FAAS) PN-88/Z-04005.06
26 Workplace environment - air - air samples collected into absorbing solution Ethanol concentration/content
Range (40 - 3200) mg/m3 Range (0,8 - 64) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-85/Z-04140/02
27 Workplace environment - air - air samples collected into absorbing solution Concentration/content of acrylamide
Range (0,017 – 3,300) mg/m3 Range (0,0010 - 0,0198) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) Test procedure PB 007 issue 3 of 02.05.2013
28 Workplace environment - air - air samples collected into absorbing solution Concentration/content of acrylamide
Range (0,0068- 2,7) mg/m3 Range (0,00081- 0,135) mg in the sample
High-performance liquid chromatography with spectrophotometric detection (HPLC-UV) PN-Z-04486:2017-10
29 Workplace environment - air - air samples collected into absorbing solution - air samples collected on sorbent tubes Methanol concentration/content
Range (8,0 – 600,0) mg/m3 Range (0,080 – 6,0) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04476:2016-10 | PN-81/Z-04028.01
30 Workplace environment - air - air samples collected on sorbent tubes and on a filter Concentration/content of mercury, its vapours and inorganic compounds - calculated as Hg
Range (0,002 - 1) mg/m3 Range (0,0001– 0,006) mg in the sample
Cold vapour atomic absorption spectrometry (CVAAS) PN-Z-04332:2006 test procedure PB 366 issue 6 of 02.05.2022
31 Workplace environment - air - air samples collected on sorbent tubes Formaldehyde concentration/content
Range (0,030- 10,0) mg/m3 Range (0,00030- 0,020) mg in the sample
High-performance liquid chromatography with spectrophotometric detection (HPLC-UV) Test procedure PB 006A issue 2 of 02.05.2013
32 Workplace environment - air - air samples collected on sorbent tubes N,N-Dimethylformamide concentration/content
Range (1,50 – 120,0) mg/m3 Range (0,495 – 39,62) ppm Range (0,0075- 0,30) mg in the sample
High-performance liquid chromatography with spectrophotometric detection (HPLC-UV) Test procedure PB 148A issue 1 of 02.05.2024
33 Workplace environment - air - air samples collected on sorbent tubes Concentration/content of ethyl acrylate
Range (2,0 - 200) mg/m3 Range (0,04 - 4,5) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-78/Z-04113/02
34 Workplace environment - air - air samples collected on sorbent tubes Methyl acrylate concentration/content
Range (1,0 - 100) mg/m3 Range (0,02 - 2) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-86/Z-04113/05
35 Workplace environment - air - air samples collected on sorbent tubes White spirit concentration/content
Range (30 - 1800) mg/m3 Range (0,6 - 18) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-81/Z-04134.03
36 Workplace environment - air - air samples collected on sorbent tubes Concentration/content of chloroethene
Range (0,5 - 64) mg/m3 Range (0,01 - 1,3) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-78/Z-04112/01
37 Workplace environment - air - air samples collected on sorbent tubes Dichloromethane concentration/content
Range (2,5 - 200) mg/m3 Range (0,05 - 4) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-77/Z-04110/01
38 Workplace environment - air - air samples collected on sorbent tubes Ethylene oxide concentration/content
Range (0,1 - 10) mg/m3 Range (0,055 – 5,5) ppm Range (0,002 - 0,2) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04300:2002
39 Workplace environment - air - air samples collected on sorbent tubes Phenol concentration/content
Range (0,1 - 16) mg/m3 Range (0,002 - 0,32) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-89/Z-04159/10
40 Workplace environment - air - air samples collected on sorbent tubes Ethylene glycol concentration/content
Range (1,5 - 150) mg/m3 Range (0,03 - 3) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) Principles and Methods of Assessing the Working Environment 1997, No. 17 pp. 55 – 59
41 Workplace environment - air - air samples collected on sorbent tubes Acetic acid concentration/content
Range (0,5 - 100) mg/m3 Range (0,20 – 40,17) ppm Range (0,025 - 5) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04323:2004
42 Workplace environment - air - air samples collected on sorbent tubes Methyl methacrylate concentration/content
Range (5 - 560) mg/m3 Range (0,1 - 11) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-92/Z-04113/09
43 Workplace environment - air - air samples collected on sorbent tubes Kerosene concentration/content
Range (10 - 1000) mg/m3 Range (0,2 - 20) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-92/Z-04227.02
44 Workplace environment - air - air samples collected on sorbent tubes Vinyl acetate concentration/content
Range (1 - 80) mg/m3 Range (0,02 - 1,6) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-87/Z-04178/02
45 Workplace environment - air - air samples collected on sorbent tubes Pentane concentration/content
Range (50 - 5000) mg/m3 Range (1 - 10) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04318:2005
46 Workplace environment - air - air samples collected on sorbent tubes Tetrachloroethene concentration/content
Range (5 - 1000) mg/m3 Range (0,73 – 145,2) ppm Range (0,1 - 20) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-83/Z-04118/02
47 Workplace environment - air - air samples collected on sorbent tubes Concentration/content of desflurane
Range (4,0 – 900,0) mg/m3 Range (0,020 – 9,6) mg in the sample
Gas chromatography with mass spectrometry detection (GC-MS) PN-Z-04422:2010
48 Workplace environment - air - air samples collected on sorbent tubes Isoflurane concentration/content
Range (1,0 – 240,0) mg/m3 Range (0,005 – 0,240) mg in the sample
Gas chromatography with mass spectrometry detection (GC-MS) PN-Z-04423:2011
49 Workplace environment - air - air samples collected on sorbent tubes Sevoflurane concentration/content
Range (2,0 – 450,0) mg/m3 Range (0,01 – 0,450) mg in the sample
Gas chromatography with mass spectrometry detection (GC-MS) PN-Z-04429:2011
50 Workplace environment - air - air samples collected on sorbent tubes Concentration/content of butane
Range (20,0 – 6000) mg/m3 Range (0,060 – 4,50) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04252-1:2012 test procedure PB 052 issue 2 of 02.05.2013
51 Workplace environment - air - air samples collected on sorbent tubes Propane concentration/content
Range (20 – 4000) mg/m3 Range (0,06 – 3,0) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04252-2:2012 test procedure PB 052 issue 2 of 02.05.2013
52 Workplace environment - air - air samples collected on sorbent tubes Benzene concentration/content
Range (0,1 - 20) mg/m3 Range (0,031 – 6,18) ppm Range (0,002 - 0,4) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) Test procedure PB 025 issue 3 of 02.05.2013
53 Workplace environment - air - air samples collected on sorbent tubes Concentration/content:
cyclohexanone, styrene Range (2,5 - 500) mg/m3 Range (0,05 - 5) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) Test procedure PB 025 issue 3 of 02.05.2013
54 Workplace environment - air - air samples collected on sorbent tubes Concentration/content of 2-methylpropan-1-ol (isobutanol)
Range (5,0 – 500,0) mg/m3 Range (0,10 – 5,0) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-89/Z-04023-02 | NIOSH 1401:1994
55 Workplace environment - air - air samples collected on sorbent tubes 2-butoxyethanol concentration/content
Range (5 - 1000) mg/m3 Range (0,1- 20) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) Test procedure PB 025 issue 3 of 02.05.2013
56 Workplace environment - air - air samples collected on sorbent tubes Concentration/content:
butan-1-ol hexane xylene – mixture of isomers: 1,2-; 1,3-; 1,4-; cumene 4-methylpentan-2-one toluene trimethylbenzene (trimethylbenzene) – mixture of isomers 1,2,3-; 1,2,4- and 1,3,5- Range (5 - 500) mg/m3 Range (0,1 - 5) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) Test procedure PB 025 issue 3 of 02.05.2013
57 Workplace environment - air - air samples collected on sorbent tubes Concentration/content:
butan-2-ol ethylbenzene 1-methoxypropan-2-ol 2-butoxyethyl acetate 2-methoxy-1-methylethyl acetate propyl acetate Range (10 - 1000) mg/m3 Range (0,2 - 10) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) Test procedure PB 025 issue 3 of 02.05.2013
58 Workplace environment - air - air samples collected on sorbent tubes Concentration/content:
butan-2-one n-butyl acetate propan-1-ol propan-2-ol Range (10 - 1500) mg/m3 Range (0,2 - 15) mg in the sample ethyl acetate Range (10 - 1500) mg/m3 Range (2,74 – 410,8) ppm Range (0,2 - 15) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) Test procedure PB 025 issue 3 of 02.05.2013
59 Workplace environment - air - air samples collected on sorbent tubes Concentration/content:
acetone extraction naphtha acyclic isomers of hexane saturated, except hexane 2,2- dimethylbutane, 2,3-dimethylbutane, 3-methylpentane, 2-methylpentane isopropyl acetate Range (10 - 2000) mg/m3 Range (0,2 - 20) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) Test procedure PB 025 issue 3 of 02.05.2013
60 Workplace environment - air - air samples collected on a filter Concentration/content of aluminium trioxide – calculated as Al – inhalable fraction – respirable fraction
Range (0,018 – 8,0) mg/m3 Range (0,00025 - 0,010) mg in the sample
Spectrophotometric method Test procedure PB 425 issue 4 of 02.05.2013
61 Workplace environment - air - air samples collected on a filter Concentration/content of highly refined mineral oils excluding metalworking fluids – inhalable fraction
Range (0,28 - 22,4) mg/m3 Range (0,15 - 10,2) mg in the sample
Spectrophotometric method PN-Z-04108-6:2006+Az1:2009
62 Workplace environment - air - air samples collected on a filter Concentration/content of chromium (VI) compounds – calculated as Cr (VI)
Range (0,0007 – 0,08) mg/m3 Range (0,0005 - 0,625) mg in the sample
Spectrophotometric method NIOSH 7600:2015
63 Workplace environment - air - air samples collected on a filter Concentration/content of chromium and its compounds (chromium (II), (III), (VI)) – calculated as Cr
Range (0,001 – 2,5) mg/m3 Range (0,0005 - 0,625) mg in the sample
Flame atomic absorption spectrometry (FAAS) Test procedure PB 092 issue 2 of 02.05.2013
64 Workplace environment - air - air samples collected on a filter Concentration of metallic chromium, chromium compounds: chromium (II) – calculated as Cr (II), chromium (III) – calculated as Cr (III) Calculation method Test procedure PB 90 issue 1 of 02.05.2021
65 Workplace environment - air - air samples collected on a filter Concentration/content of tin and its inorganic compounds, except stannane – calculated as Sn – inhalable fraction
Range (0,125 – 20) mg/m3 Range (0,05 - 6) mg in the sample
Flame atomic absorption spectrometry (FAAS) PN-Z-04488:2017-10
66 Workplace environment - air - air samples collected on a filter Concentration/content of cadmium and its inorganic compounds – calculated as Cd
inhalable fraction respirable fraction Range (0,0002 - 0,027) mg/m3 Range (0,0001- 0,2) mg in the sample
Flame atomic absorption spectrometry (FAAS) PN-Z-04102-3:2013-10
67 Workplace environment - air - air samples collected on a filter Concentration/content of manganese and its inorganic compounds – expressed as Mn
inhalable fraction respirable fraction Range (0,004- 2,5) mg/m3 Range (0,0015 - 0,45) mg in the sample
Flame atomic absorption spectrometry (FAAS) PN-Z-04472:2015-10+Ap1:2015-12
68 Workplace environment - air - air samples collected on a filter Concentration/content of copper and its inorganic compounds – calculated as Cu
Range (0,0014 - 0,5) mg/m3 Range (0,0005 - 0,1) mg in the sample
Flame atomic absorption spectrometry (FAAS) PN-Z-04106-3:2002
69 Workplace environment - air - air samples collected on a filter Concentration/content of nickel and its compounds, except nickel tetracarbonyl – calculated as Ni
Range (0,007 - 1,3) mg/m3 Range (0,0025 - 0,4) mg in the sample
Flame atomic absorption spectrometry (FAAS) PN-Z-04502:2019-10
70 Workplace environment - air - air samples collected on a filter Concentration/content of lead and its inorganic compounds, excluding lead (II) arsenate (V) and lead (II) chromate (VI) - calculated as Pb
inhalable fraction Range (0,004 - 0,3) mg/m3 Range (0,002 - 0,5) mg in the sample
Flame atomic absorption spectrometry (FAAS) PN-Z-04487:2017-10
71 Workplace environment - air - air samples collected on a filter Concentration/content of silver - inhalable fraction, insoluble silver compounds – calculated as Ag, soluble silver compounds – calculated as Ag
Range (0,001 - 0,3) mg/m3 Range (0,001 - 0,4) mg in the sample
Flame atomic absorption spectrometry (FAAS) PN-Z-04216-2:2012 Principles and Methods of Assessing the Working Environment 1998, No. 19 pp. 165 – 169
72 Workplace environment - air - air samples collected on a filter Concentration/content of zinc oxide – calculated as Zn – inhalable fraction
Range (0,03 - 20) mg/m3 Range (0,002 - 0,2) mg in the sample
Flame atomic absorption spectrometry (FAAS) PN-87/Z-04100/03
73 Workplace environment - air - air samples collected on a filter Calcium oxide concentration/content
inhalable fraction respirable fraction Range (0,04 - 12) mg/m3 Range (0,007 - 1) mg in the sample
Flame atomic absorption spectrometry (FAAS) PN-Z-04442:2023-05
74 Workplace environment - air - air samples collected on a filter Concentration/content of iron oxides – calculated as Fe – respirable fraction – inhalable fraction
Range (0,25 - 30) mg/m3 Range (0,005 - 1,2) mg in the sample
Flame atomic absorption spectrometry (FAAS) PN-Z-04469:2015-10
75 Workplace environment - air - air samples collected on a filter Potassium hydroxide concentration/content
Range (0,004 – 4,8) mg/m3 Range (0,0014 – 0,14) mg in the sample
Flame atomic absorption spectrometry (FAAS) PN-Z-04436:2011
76 Workplace environment - air - air samples collected on a filter Sodium hydroxide concentration/content
Range (0,005 – 5,8) mg/m3 Range (0,0017 – 0,17) mg in the sample
Flame atomic absorption spectrometry (FAAS) PN-Z-04435:2011
77 Workplace environment - air - air samples collected on a filter Concentration/content of highly refined mineral oils excluding metalworking fluids – inhalable fraction
Range (0,28 – 22,4) mg/m3 Range (0,15 - 10,2) mg in the sample
Infrared spectrometry (FT-IR) PN-Z-04108-5:2006
78 Workplace environment - air - air samples collected on a filter Concentration/content of dibutyl phthalate – inhalable fraction
Range (0,5 - 20) mg/m3 Range (0,25 - 10) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-89/Z-04208/04
79 Workplace environment - air - air samples collected on a filter Bis(2-ethylhexyl) phthalate concentration/content
Range (0,1 - 20) mg/m3 Range (0,05 - 10) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-89/Z-04208/05
80 Workplace environment - air - air samples collected on a filter Concentration/content of toluene-2,4-diyl diisocyanate (2,4-TDI)
Range (0,0005 – 1,33) mg/m3 Range (0,0001 – 0,02) mg in the sample
High-performance liquid chromatography with fluorimetric detection (HPLC-FLD) PN-Z-04490:2017-10
81 Workplace environment - air - air samples collected on a filter Concentration/content of toluene-2,6-diyl diisocyanate (2,6-TDI)
Range (0,0005 – 1,33) mg/m3 Range (0,0001 – 0,02) mg in the sample
High-performance liquid chromatography with fluorimetric detection (HPLC-FLD) PN-Z-04490:2017-10
82 Workplace environment - air - air samples collected on a filter Concentration/content of methylenebis (phenyl isocyanate) (MDI)
Range (0,0005 – 1,33) mg/m3 Range (0,0001 – 0,02) mg in the sample
High-performance liquid chromatography with fluorimetric detection (HPLC-FLD) Test procedure PB 136A issue 2 of 02.05.2013
83 Workplace environment - indoor electric lighting Illuminance
Range (0,5 – 9000) lx
Direct measurement method Test procedure PB 12464 issue 3 of 02.05.2016
84 Workplace environment - indoor electric lighting Illuminance uniformity (calculated) Test procedure PB 12464 issue 3 of 02.05.2016
85 Workplace environment - emergency lighting Illuminance
Range (0,5 – 1000) lx
Direct measurement method PN-EN 1838:2025-05 Method A
86 Workplace environment - emergency lighting Ratio of minimum to maximum illuminance (calculated) PN-EN 1838:2025-05 Method A
87 Workplace environment - emergency lighting Illuminance uniformity for the high-risk zone (calculated) PN-EN 1838:2025-05 Method A
88 Workplace environment - moderate microclimate Air temperature:
Range (10 – 30) °C Black globe temperature: Range (10 – 40) °C Air humidity: Range (20 – 90) % Air velocity: Range (0,15 – 5) m/s
Direct measurement method PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04
89 Workplace environment - moderate microclimate PMV index, PPD index (calculated) PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04
90 Workplace environment - hot microclimate Air temperature:
Range (10 – 60) °C Natural wet bulb temperature: Range (10 – 60) °C Black globe temperature: Range (10 – 60) °C
Direct measurement method PN-EN ISO 7243:2018 -01
91 Workplace environment - hot microclimate WBGT index, WBGTeff index (calculated) PN-EN ISO 7243:2018 -01
92 Workplace environment - cold microclimate Air temperature:
Range (- 30 – 10) °C Black globe temperature: Range (- 30 – 15) °C Air humidity: Range (20 – 90) % Air velocity: Range (0,15 – 5) m/s
Direct measurement method PN-EN ISO 11079:2008
93 Workplace environment - cold microclimate tWC index, IREQmin index, IREQneutral index (calculated) PN-EN ISO 11079:2008
94 Workplace environment - noise A-weighted equivalent sound level Maximum A-weighted sound level
Range (30 - 135) dB C-weighted peak sound pressure level Range (50 - 140) dB
Direct measurement method PN-N-01307:1994 | PN-EN ISO 9612:2011 excluding the method covering strategy 2 - cl. 10 and strategy 3 - cl. 11
95 Workplace environment - noise Noise exposure level referred to:
an 8-hour daily working time the average weekly working time (calculated)
PN-N-01307:1994 | PN-EN ISO 9612:2011 excluding the method covering strategy 2 - cl. 10 and strategy 3 - cl. 11
96 Workplace environment - hand-arm vibration Frequency-weighted r.m.s. vibration acceleration
Range (0,32 – 300) m/s2
Direct measurement method PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004 / A1:2015
97 Workplace environment - hand-arm vibration Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the vector sum of the r.m.s. frequency-corrected vibration accelerations determined for three directional components (ahwx, ahwy, ahwz), Exposure lasting 30 minutes or less, expressed as the vector sum of the r.m.s. frequency-weighted vibration accelerations determined for three directional components (ahwx, ahwy, ahwz) (calculated) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004 / A1:2015
98 Workplace environment - whole-body vibration Frequency-weighted r.m.s. vibration acceleration
Range (0,04 – 35) m/s2
Direct measurement method PN-EN 14253+A1:2011
99 Workplace environment - whole-body vibration Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the r.m.s. frequency-corrected vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1,4awx, 1,4awy, awz), Exposure lasting 30 minutes or less, expressed as the r.m.s. frequency-weighted vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1,4awx, 1,4awy, awz) (calculated) PN-EN 14253+A1:2011
100 Waste gases Gas volume flow rate for dynamic pressures > 10 Pa
Velocity Range (0,5 – 20,0) m/s
Stagnation pressure method; Thermoanemometric method PN-Z-04030-7:1994
101 Waste gases Sampling for determination of concentrations of organic compounds Aspiration method using activated carbon PN-Z-04008-4:1999
102 Waste gases Concentration of oxygen, carbon monoxide, nitrogen monoxide, nitrogen dioxide, sulphur dioxide SO2, CO2, NO, CO, O2, NO2:
SO2 (9 - 1500) mg/m3 CO2 ( 0 , 1 – 1 4 ) % NO ( 1 3 - 7 0 0 ) m g/m3 NO2 (8 – 40) mg/m3 CO (25 – 1000) mg/m3 O2 Range (3 - 15) %
Non-dispersive infrared spectrometry (NDIR); Electrochemical method PN ISO 10396:2001
103 Waste gases Emission of CO, NO and NO2, NOx (NO and NO2 calculated as NO2 ), SO2, CO2 (calculated) PN ISO 10396:2001
104 Waste gases Total organic carbon concentration (TVOC)
Range (0,6 – 1000) mg/m3
Continuous flame ionization detection method (FID) PN-EN 12619:2013-05
105 Waste gases TVOC emission (calculated) PN-EN 12619:2013-05
106 Waste gases Sampling for determination of dust concentration PN-EN 13284-1:2018-02 CEN/TR 17078:2017
107 Waste gases Dust concentration
Range (0,5 - 50) mg/m3
Gravimetric method PN-EN 13284-1:2018-02 CEN/TR 17078:2017
108 Waste gases Dust emission (calculated) PN-EN 13284-1:2018-02 CEN/TR 17078:2017
109 Waste gases Sampling for determination of the concentration of individual gaseous organic compounds PN-EN 13649:2005
110 Waste gases Benzene concentration
Range (0,1 - 20) mg/m3
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005
111 Waste gases Concentration:
cyclohexanone, styrene Range (2,5 - 500) mg/m3
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005
112 Waste gases Concentration:
butan-2-ol ethylbenzene 1-methoxypropan-2-ol 2-butoxyethyl acetate 2-methoxy-1-methylethyl acetate propyl acetate Range (10 - 1000) mg/m3
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005
113 Waste gases Concentration:
butan-1-ol hexane xylene – mixture of isomers: 1,2-; 1,3-; 1,4-; cumene 4-methylpentan-2-one toluene trimethylbenzene (trimethylbenzene) – mixture of isomers 1,2,3-; 1,2,4- and 1,3,5- Range (5 - 500) mg/m3
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005
114 Waste gases 2-butoxyethanol concentration
Range (5 - 1000) mg/m3
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005
115 Waste gases Concentration:
butan-2-one n-butyl acetate ethyl acetate propan-1-ol propan-2-ol Range (10 - 1500) mg/m3
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005
116 Waste gases Concentration:
acetone extraction naphtha acyclic isomers of hexane saturated, except hexane 2,2- dimethylbutane, 2,3-dimethylbutane, 3-methylpentane, 2-methylpentane isopropyl acetate Range (10 - 2000) mg/m3
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005
117 Waste gases Emission of the above-mentioned organic compounds (calculated) PN-EN 13649:2005
118 Waste gases Sampling for the determination of mercury concentration PN-EN 13211+AC:2006
119 Waste gases Mercury concentration
Range (0,00042 – 1,0) mg/m3 Range (0,000025 – 0,06) mg in the sample
Cold vapour atomic absorption spectrometry (CVAAS) PN-EN 13211+AC:2006
120 Waste gases Mercury emission (calculated) PN-EN 13211+AC:2006
121 Waste gases Sampling for determination of methanol PN-EN 13649:2005
122 Waste gases Methanol concentration
Range (8 – 600) mg/m3
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005
123 Waste gases Methanol emission (calculated) PN-EN 13649:2005
124 Waste gases Sampling for the determination of hydrogen chloride PN-EN 1911:2011
125 Waste gases Hydrogen chloride concentration
Range (0,67 - 50) mg/m3
Spectrophotometric method PN-EN 1911:2011
126 Waste gases Hydrogen chloride emission (calculated) PN-EN 1911:2011
127 Waste gases Water vapour content
Range (29 – 250) g/m3 Range (4 – 40) %
Adsorption method PN-EN 14790:2017-04
128 Waste gases Sampling for determination of chromium concentration in dust Aspiration method Test procedure PB 092 issue 2 of 02.05.2013
129 Waste gases Chromium concentration in dust
Range (0,006 – 2,5) mg/m3
Flame atomic absorption spectrometry (FAAS) Test procedure PB 092 issue 2 of 02.05.2013
130 Waste gases Emission of chromium in dust (calculated) Test procedure PB 092 issue 2 of 02.05.2013
131 Waste gases Sampling for determination of tin concentration in dust Aspiration method Test procedure PB 095 issue 2 of 02.05.2013
132 Waste gases Tin concentration in dust
Range (0,125 – 20) mg/m3
Flame atomic absorption spectrometry (FAAS) Test procedure PB 095 issue 2 of 02.05.2013
133 Waste gases Emission of tin in dust (calculated) Test procedure PB 095 issue 2 of 02.05.2013
134 Waste gases Sampling for the determination of hydrogen sulphide Aspiration method Test procedure PB 370 issue 5 of 02.05.2013
135 Waste gases Hydrogen sulphide concentration
Range (0,67 - 33,3) mg/m3
Spectrophotometric method Test procedure PB 370 issue 5 of 02.05.2013
136 Waste gases Hydrogen sulphide emission (calculated) Test procedure PB 370 issue 5 of 02.05.2013
137 Waste gases Sampling for determination of formaldehyde concentration Aspiration method CEN/TS 17638:2021 test procedure PB 197 issue 2 of 21.11.2022
138 Waste gases Formaldehyde concentration
Range (0,050 – 10,0) mg/m3
Spectrophotometric method CEN/TS 17638:2021 test procedure PB 197 issue 2 of 21.11.2022
139 Waste gases Formaldehyde emission (calculated) CEN/TS 17638:2021 test procedure PB 197 issue 2 of 21.11.2022
140 Waste gases Sampling for determination of hydrogen cyanide and cyanides – expressed as CN (hydrogen cyanide, sodium cyanide, potassium cyanide, calcium cyanide) Aspiration method Test procedure PB 094A issue 3 of 02.05.2013
141 Waste gases Concentration of hydrogen cyanide and cyanides – calculated as CN (hydrogen cyanide, sodium cyanide, potassium cyanide, calcium cyanide)
Range (0,063 - 12,5) mg/m3
Potentiometric method Test procedure PB 094A issue 3 of 02.05.2013
142 Waste gases Emission of hydrogen cyanide and cyanides – calculated as CN (hydrogen cyanide, sodium cyanide, potassium cyanide, calcium cyanide) (calculated) Test procedure PB 094A issue 3 of 02.05.2013
143 Waste gases Sampling for determination of the concentration of 4,4’-methylenebis(phenyl isocyanate) (MDI), toluene-2,4-diyl diisocyanate (2,4-TDI), toluene-2,6-diyl diisocyanate (2,6-TDI) Aspiration method Test procedure PB 136A issue 2 of 02.05.2013
144 Waste gases 4,4’-methylenebis (phenyl isocyanate) (MDI) concentration
Range (0,0005 – 1,33) mg/m3
High-performance liquid chromatography with fluorimetric detection (HPLC-FLD) Test procedure PB 136A issue 2 of 02.05.2013
145 Waste gases Toluene-2,4-diyl diisocyanate (2,4-TDI) concentration
Range (0,0005 – 1,33) mg/m3
High-performance liquid chromatography with fluorimetric detection (HPLC- FLD) Test procedure PB 136A issue 2 of 02.05.2013
146 Waste gases Toluene-2,6-diyl diisocyanate (2,6-TDI) concentration
Range (0,0005 – 1,33) mg/m3
High-performance liquid chromatography with fluorimetric detection (HPLC- FLD) Test procedure PB 136A issue 2 of 02.05.2013
147 Waste gases Emission of 4,4’-methylenebis(phenyl isocyanate) (MDI), toluene-2,4-diyl diisocyanate (2,4-TDI), toluene-2,6-diyl diisocyanate (2,6-TDI) (calculated) Test procedure PB 136A issue 2 of 02.05.2013
148 Waste gases Sampling for the determination of formaldehyde Aspiration method Test procedure PB 006A issue 2 of 02.05.2013
149 Waste gases Formaldehyde concentration
Range (0,030 – 10,0) mg/m3
High-performance liquid chromatography with spectrophotometric detection (HPLC-UV) Test procedure PB 006A issue 2 of 02.05.2013
150 Waste gases Formaldehyde emission (calculated) Test procedure PB 006A issue 2 of 02.05.2013
151 Waste gases Sampling for determination of hydrogen fluoride and fluorides expressed as F- Aspiration method Test procedure PB 192 issue 5 of 02.05.2013
152 Waste gases Concentration of hydrogen fluoride and fluorides calculated as F-
Range (0,033 - 13,3) mg/m3
Potentiometric method Test procedure PB 192 issue 5 of 02.05.2013
153 Waste gases Emission of hydrogen fluoride and fluorides calculated as F-(calculated) Test procedure PB 192 issue 5 of 02.05.2013
154 Waste gases Sampling for determination of methanol Aspiration method Test procedure PB 272 issue 2 of 02.05.2013
155 Waste gases Methanol concentration
Range (8 – 400) mg/m3
Gas chromatography with flame ionization detection (GC-FID) Test procedure PB 272 issue 2 of 02.05.2013
156 Waste gases Methanol emission (calculated) Test procedure PB 272 issue 2 of 02.05.2013
157 Waste gases Sampling for determination of the concentration of 2-methylpropan-1-ol (isobutanol) Aspiration method PN-EN 13649:2005 | NIOSH 1401:1994
158 Waste gases 2-methylpropan-1-ol (isobutanol) concentration
Range (5,0 – 500,0) mg/m3
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005 | NIOSH 1401:1994
159 Waste gases Emission of 2-methylpropan-1-ol (isobutanol) (calculated) PN-EN 13649:2005 | NIOSH 1401:1994
160 Waste gases Sampling for determination of ammonia concentration Aspiration method Test procedure PB 019 issue 4 of 02.05.2013 | PN-EN ISO 21877:2020-03
161 Waste gases Ammonia concentration
Range (0,02 – 80) mg/m3
Spectrophotometric method Test procedure PB 019 issue 4 of 02.05.2013 | PN-EN ISO 21877:2020-03
162 Waste gases Ammonia emission (calculated) Test procedure PB 019 issue 4 of 02.05.2013 | PN-EN ISO 21877:2020-03
163 Waste gases Sampling for the determination of chlorine concentration Aspiration method Test procedure PB 062 issue 3 of 02.05.2013
164 Waste gases Chlorine concentration
Range (0,13 – 10) mg/m3
Spectrophotometric method Test procedure PB 062 issue 3 of 02.05.2013
165 Waste gases Chlorine emission (calculated) Test procedure PB 062 issue 3 of 02.05.2013
166 Waste gases, General environment - waste gas samples collected on sorbent tubes Sampling for determination of butane concentration Aspiration method PN-Z-04252-1:2012 test procedure PB 052 issue 2 of 02.05.2013
167 Waste gases, General environment - waste gas samples collected on sorbent tubes Concentration/content of butane
Range (20,0 - 6000) mg/m3 Range (0,060 – 4,50) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04252-1:2012 test procedure PB 052 issue 2 of 02.05.2013
168 Waste gases, General environment - waste gas samples collected on sorbent tubes Emission of butane (calculated) PN-Z-04252-1:2012 test procedure PB 052 issue 2 of 02.05.2013
169 Waste gases, General environment - waste gas samples collected on sorbent tubes Sampling for determination of propane concentration Aspiration method PN-Z-04252-2:2012 test procedure PB 052 issue 2 of 02.05.2013
170 Waste gases, General environment - waste gas samples collected on sorbent tubes Propane concentration/content
Range (20 – 4000) mg/m3 Range (0,06 – 3,0) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04252-2:2012 test procedure PB 052 issue 2 of 02.05.2013
171 Waste gases, General environment - waste gas samples collected on sorbent tubes Emission of propane (calculated) PN-Z-04252-2:2012 test procedure PB 052 issue 2 of 02.05.2013
172 Waste gases Sampling for determination of the concentration of sulfuric (VI) acid and sulfur trioxide Aspiration method Test procedure PB 270 issue 2 of 02.05.2013
173 Waste gases Sulphuric acid (VI) and sulphur trioxide concentration
Range (0,05 - 10) mg/m3
Spectrophotometric method Test procedure PB 270 issue 2 of 02.05.2013
174 Waste gases Emission of sulphuric acid and sulphur trioxide (calculated) Test procedure PB 270 issue 2 of 02.05.2013
175 Waste gases Sampling for the determination of ozone concentration Aspiration method Test procedure PB 341 issue 5 of 02.05.2013
176 Waste gases Ozone concentration
Range (0,013 - 10) mg/m3
Spectrophotometric method Test procedure PB 341 issue 5 of 02.05.2013
177 Waste gases Ozone emission (calculated) Test procedure PB 341 issue 5 of 02.05.2013
178 Waste gases Sampling for determination of the concentration of chromium (VI) compounds expressed as chromium (VI) Aspiration method Test procedure PB 093 issue 2 of 23.11.2021
179 Waste gases Concentration of chromium (VI) compounds – calculated as Cr (VI)
Range (0,0005 - 0,6) mg/m3
Spectrophotometric method NIOSH 7600:2015
180 Waste gases Emission of chromium (VI) compounds calculated as chromium (VI) (calculated) Test procedure PB 093 issue 2 of 23.11.2021
181 Waste gases Sampling for determination of potassium hydroxide concentration Aspiration method Test procedure PB 435 issue 2 of 02.05.2013
182 Waste gases Potassium hydroxide concentration
Range (0,05 - 9,5) mg/m3
Flame atomic absorption spectrometry (FAAS) Test procedure PB 435 issue 2 of 02.05.2013
183 Waste gases Emission of potassium hydroxide (calculated) Test procedure PB 435 issue 2 of 02.05.2013
184 Waste gases Sampling for determination of sodium hydroxide concentration Aspiration method Test procedure PB 435 issue 2 of 02.05.2013
185 Waste gases Sodium hydroxide concentration
Range (0,06 - 11,6) mg/m3
Flame atomic absorption spectrometry (FAAS) Test procedure PB 435 issue 2 of 02.05.2013
186 Waste gases Emission of sodium hydroxide (calculated) Test procedure PB 435 issue 2 of 02.05.2013
187 General environment - waste gas samples collected on a filter Chromium content
Range (0,0025 – 0,625) mg in the sample
Flame atomic absorption spectrometry (FAAS) Test procedure PB 092 issue 2 of 02.05.2013
188 General environment - waste gas samples collected on a filter Tin content
Range (0,05 – 6) mg in the sample
Flame atomic absorption spectrometry (FAAS) Test procedure PB 095 issue 2 of 02.05.2013
189 General environment - waste gas samples collected on a filter 4,4’-methylenebis (phenyl isocyanate) (MDI) content
Range (0,0001 - 0,02) mg in the sample
High-performance liquid chromatography with fluorimetric detection (HPLC-FLD) Test procedure PB 136A issue 2 of 02.05.2013
190 General environment - waste gas samples collected on a filter Toluene-2,4-diyl diisocyanate (2,4-TDI) content
Range (0,0001 - 0,02) mg in the sample
High-performance liquid chromatography with fluorimetric detection (HPLC- FLD) Test procedure PB 136A issue 2 of 02.05.2013
191 General environment - waste gas samples collected on a filter Toluene-2,6-diyl diisocyanate (2,6-TDI) content
Range (0,0001 - 0,02) mg in the sample
High-performance liquid chromatography with fluorimetric detection (HPLC- FLD) Test procedure PB 136A issue 2 of 02.05.2013
192 General environment - waste gas samples collected on a filter Mercury content
Range (0,000025 - 0,06) mg in the sample
Cold vapour atomic absorption spectrometry (CVAAS) PN-EN 13211+AC:2006
193 General environment - waste gas samples collected on a filter Content of chromium (VI) compounds – expressed as Cr (VI)
Range (0,0005 - 0,06) mg in the sample
Spectrophotometric method NIOSH 7600:2015
194 General environment - waste gas samples collected on sorbent tubes Formaldehyde content
Range (0,00030 - 0,020) mg in the sample
High-performance liquid chromatography with spectrophotometric detection (HPLC-UV) Test procedure PB 006A issue 2 of 02.05.2013
195 General environment - waste gas samples collected on sorbent tubes Benzene content
Range (0,002 - 0,4) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005
196 General environment - waste gas samples collected on sorbent tubes Content:
cyclohexanone, styrene Range (0,05 - 10) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005
197 General environment - waste gas samples collected on sorbent tubes Content:
butan-1-ol hexane xylene – mixture of isomers: 1,2-; 1,3-; 1,4-; cumene 4-methylpentan-2-one toluene trimethylbenzene (trimethylbenzene) – mixture of isomers 1,2,3-; 1,2,4- and 1,3,5- Range (0,1 – 10) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005
198 General environment - waste gas samples collected on sorbent tubes 2-methylpropan-1-ol (isobutanol) content
Range (0,10 – 5,0) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-89/Z-04023-02 | NIOSH 1401:1994
199 General environment - waste gas samples collected on sorbent tubes 2-butoxyethanol content
Range (0,1 - 20) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005
200 General environment - waste gas samples collected on sorbent tubes Content:
butan-2-ol ethylbenzene 1-methoxypropan-2-ol 2-butoxyethyl acetate 2-methoxy-1-methylethyl acetate propyl acetate Range (0,2 - 20) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005
201 General environment - waste gas samples collected on sorbent tubes Content:
butan-2-one n-butyl acetate ethyl acetate propan-1-ol propan-2-ol Range (0,2 - 20) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005
202 General environment - waste gas samples collected on sorbent tubes Content:
acetone extraction naphtha acyclic isomers of hexane saturated, except hexane 2,2- dimethylbutane, 2,3-dimethylbutane, 3-methylpentane, 2-methylpentane isopropyl acetate Range (0,2 - 20) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005
203 General environment - waste gas samples collected into absorbing solution Content of hydrogen cyanide and cyanides – calculated as CN (hydrogen cyanide, sodium cyanide, potassium cyanide, calcium cyanide)
Range (0,0005 - 0,05) mg in the sample
Potentiometric method Test procedure PB 094A issue 3 of 02.05.2013
204 General environment - waste gas samples collected into absorbing solution Hydrogen fluoride and fluoride content calculated as F-
Range (0,001 - 0,1) mg in the sample
Potentiometric method Test procedure PB 192 issue 5 of 02.05.2013
205 General environment - waste gas samples collected into absorbing solution Ammonia content
Range (0,0002 – 0,08) mg in the sample
Spectrophotometric method Test procedure PB 019 issue 4 of 02.05.2013 | PN-EN ISO 21877:2020-03
206 General environment - waste gas samples collected into absorbing solution Chlorine content
Range (0,001 - 0,05) mg in the sample
Spectrophotometric method Test procedure PB 062 issue 3 of 02.05.2013
207 General environment - waste gas samples collected into absorbing solution Hydrogen chloride content
Range (0,01 - 0,2) mg in the sample
Spectrophotometric method PN-EN 1911:2011
208 General environment - waste gas samples collected into absorbing solution Sulphuric (VI) acid and sulphur trioxide content
Range (0,025 - 0,55) mg in the sample
Spectrophotometric method Test procedure PB 270 issue 2 of 02.05.2013
209 General environment - waste gas samples collected into absorbing solution Ozone content
Range (0,0002 – 0,005) mg in the sample
Spectrophotometric method Test procedure PB 341 issue 5 of 02.05.2013
210 General environment - waste gas samples collected into absorbing solution Potassium hydroxide content
Range (0,0007 - 0,014) mg in the sample
Flame atomic absorption spectrometry (FAAS) Test procedure PB 435 issue 2 of 02.05.2013
211 General environment - waste gas samples collected into absorbing solution Sodium hydroxide content
Range (0,0009 - 0,018) mg in the sample
Flame atomic absorption spectrometry (FAAS) Test procedure PB 435 issue 2 of 02.05.2013
212 General environment - waste gas samples collected into absorbing solution Hydrogen sulphide content
Range (0,005 – 0,05) mg in the sample
Spectrophotometric method Test procedure PB 370 issue 5 of 02.05.2013
213 General environment - waste gas samples collected into absorbing solution Formaldehyde content
Range (0,00050 – 0,020) mg in the sample
Spectrophotometric method CEN/TS 17638:2021 test procedure PB 197 issue 2 of 21.11.2022
214 General environment - waste gas samples collected into absorbing solution Mercury content
Range (0,000025 - 0,06) mg in the sample
Cold vapour atomic absorption spectrometry (CVAAS) PN-EN 13211+AC:2006
215 General environment - waste gas samples collected into absorbing solution - waste gas samples collected on sorbent tubes Methanol content
Range (0,080 – 6,0) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) Test procedure PB 272 issue 2 of 02.05.2013 | PN-EN 13649:2005 | PN-Z-04476:2016-10

Reference standards (106)

CEN/TS 17638:2021 test procedure PB 197 issue 2 of 21.11.2022
NIOSH 1401:1994
NIOSH 7600:2015
PN ISO 10396:2001
PN-71/Z-04041
PN-75/Z-04037.03
PN-77/Z-04110/01
PN-78/Z-04112/01
PN-78/Z-04113/02
PN-81/Z-04028.01
PN-81/Z-04134.03
PN-83/Z-04118/02
PN-85/Z-04140/02
PN-86/Z-04113/05
PN-87/Z-04005.05
PN-87/Z-04100/03
PN-87/Z-04178/02
PN-88/Z-04005.06
PN-88/Z-04196.02
PN-89/Z-04023-02
PN-89/Z-04159/10
PN-89/Z-04208/04
PN-89/Z-04208/05
PN-92/Z-04113/09
PN-92/Z-04227.02
PN-EN 12619:2013-05
PN-EN 13211+AC:2006
PN-EN 13284-1:2018-02 CEN/TR 17078:2017
PN-EN 13649:2005
PN-EN 14253+A1:2011
PN-EN 14790:2017-04
PN-EN 1838:2025-05 Method A
PN-EN 1911:2011
PN-EN ISO 11079:2008
PN-EN ISO 21877:2020-03
PN-EN ISO 5349-1:2004
PN-EN ISO 5349-2:2004
PN-EN ISO 5349-2:2004 / A1:2015
PN-EN ISO 7243:2018 -01
PN-EN ISO 7730:2006
PN-EN ISO 7730:2006/Ap2:2016-04
PN-EN ISO 9612:2011 excluding the method covering strategy 2 - cl. 10 and strategy 3 - cl. 11
PN-N-01307:1994
PN-Z-04008-4:1999
PN-Z-04008-7:2002+Az1:2004
PN-Z-04009-11:2008
PN-Z-04015-12:1996
PN-Z-04015-13:1996
PN-Z-04030-7:1994
PN-Z-04073-1:2014-08
PN-Z-04102-3:2013-10
PN-Z-04106-3:2002
PN-Z-04108-5:2006
PN-Z-04108-6:2006+Az1:2009
PN-Z-04216-2:2012 Principles and Methods of Assessing the Working Environment 1998, No. 19 pp. 165 – 169
PN-Z-04252-1:2012 test procedure PB 052 issue 2 of 02.05.2013
PN-Z-04252-2:2012 test procedure PB 052 issue 2 of 02.05.2013
PN-Z-04300:2002
PN-Z-04318:2005
PN-Z-04323:2004
PN-Z-04332:2006 test procedure PB 366 issue 6 of 02.05.2022
PN-Z-04422:2010
PN-Z-04423:2011
PN-Z-04429:2011
PN-Z-04435:2011
PN-Z-04436:2011
PN-Z-04442:2023-05
PN-Z-04469:2015-10
PN-Z-04472:2015-10+Ap1:2015-12
PN-Z-04476:2016-10
PN-Z-04486:2017-10
PN-Z-04487:2017-10
PN-Z-04488:2017-10
PN-Z-04490:2017-10
PN-Z-04502:2019-10
PN-Z-04507:2022-05
PN-Z-04507:2022-05+Ap1:2022-08
PN-Z-04508:2022-05
PN-Z-04508:2022-05+Ap1:2022-08
Principles and Methods of Assessing the Working Environment 1997, No. 17 pp. 55 – 59
Principles and Methods of Assessing the Working Environment 2012, No. 4 (74), pp. 117–130
Test procedure PB 006 issue 4 of 02.05.2013
Test procedure PB 006A issue 2 of 02.05.2013
Test procedure PB 007 issue 3 of 02.05.2013
Test procedure PB 019 issue 4 of 02.05.2013
Test procedure PB 025 issue 3 of 02.05.2013
Test procedure PB 062 issue 3 of 02.05.2013
Test procedure PB 089 issue 2 of 02.05.2013
Test procedure PB 092 issue 2 of 02.05.2013
Test procedure PB 093 issue 2 of 23.11.2021
Test procedure PB 094A issue 3 of 02.05.2013
Test procedure PB 095 issue 2 of 02.05.2013
Test procedure PB 12464 issue 3 of 02.05.2016
Test procedure PB 136A issue 2 of 02.05.2013
Test procedure PB 148A issue 1 of 02.05.2024
Test procedure PB 192 issue 5 of 02.05.2013
Test procedure PB 196 issue 4 of 02.05.2013
Test procedure PB 270 issue 2 of 02.05.2013
Test procedure PB 272 issue 2 of 02.05.2013
Test procedure PB 299 issue 5 of 02.05.2023
Test procedure PB 341 issue 5 of 02.05.2013
Test procedure PB 370 issue 5 of 02.05.2013
Test procedure PB 398 issue 2 of 02.05.2013
Test procedure PB 425 issue 4 of 02.05.2013
Test procedure PB 435 issue 2 of 02.05.2013
Test procedure PB 90 issue 1 of 02.05.2021

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/PL/AB%20875