🇵🇱 PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI Sp. z o.o. PL

PCA AB 862 • Jarocin, Poland • 36 methods

Water & wastewaterMicrobiology

PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI Sp. z o.o. is a laboratory accredited by PCA under number AB 862 (Jarocin, Poland). Its accreditation scope covers 36 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water, wastewater, Water, water intended for human consumption, swimming pool water, Sewage sludge, Wastewater. Most frequently used techniques: Spectrophotometric method, Membrane filtration method, Gravimetric method.

At a glance

  • Accreditation number: PCA AB 862
  • Methods in scope: 36
  • Types of test objects: 11
  • Techniques used: 11
  • City: Jarocin, Poland
Accreditation number
AB 862
Accreditation body
PCA
Address
W JAROCINIE, LABORATORIUM, ul. Gajówka 1, Cielcza, 63-200 Jarocin
City
Jarocin, Poland

What this laboratory tests (11)

Analytical techniques used (11)

Certificate information

Issue date
21.11.2025
Issue no.
20

Accreditation scope — test methods (36)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Water, wastewater pH
Range 4,0 – 10,0
Potentiometric method PN-EN ISO 10523:2012
2 Water, wastewater Ammonium ion concentration
Range (0,03 – 130,0) mg/l N-NH4 Range (0,04 – 167) mg/l NH4
Spectrophotometric method PB 24-LCK 302-304 issue 4 of 25.09.2011 | based on the Hach Lange cuvette test No. LCK 302, LCK 303, LCK 304
3 Water, wastewater Nitrate concentration
Range (1,0 – 60) mg/l NO3 Range (0,23 – 13,5) mg/l N-NO3
Spectrophotometric method PB 24-LCK 339 issue 5 of 31.08.2022 | based on the Hach Lange cuvette test No. LCK 339
4 Water, wastewater Nitrite concentration
Range (0,05 – 2,0) mg/l NO2 Range (0,015 – 0,60) mg/l N-NO2
Spectrophotometric method PB 24-LCK 341 issue 4 of 25.09.2011 | based on the Hach Lange cuvette test No. LCK 341
5 Water, wastewater Total nitrogen concentration
Range (1,0 – 500) mg/l
Spectrophotometric method PB 24-LCK 138-338 issue 5 of 21.08.2014 | based on the Hach Lange cuvette test No. LCK 138 and LCK 338
6 Water, wastewater Chloride concentration
Range (5,0 – 5000) mg/l
Titrimetric method PN-ISO 9297:1994
7 Water, wastewater Chemical oxygen demand
COD-Cr Range (5,0 – 10 000) mg/l O2
Spectrophotometric method PN-ISO 15705:2005
8 Water, wastewater Total phosphorus concentration
Range (0,05 – 200) mg/l P Range (0,15 – 60) mg/l PO4
Spectrophotometric method PB 24-LCK 348-350 issue 5 of 21.08.2014 | based on Hach Lange cuvette tests No. LCK 348, LCK 349, LCK 350
9 Water, wastewater Biochemical oxygen demand
BOD5 Range (3,0 – 6000) mg/l O2
Electrochemical method PN-EN ISO 5815-1:2019-12
10 Water, wastewater Biochemical oxygen demand
BOD5 Range (0,7 – 6,0) mg/l O2
Electrochemical method PN-EN 1899-2:2002
11 Water, wastewater Sulfate concentration
Range (40 – 900) mg/l
Spectrophotometric method PB 24-LCK 153-353 issue 2 of 01.12.2010 | based on the Hach Lange cuvette test No. LCK 153 and LCK 353
12 Water, wastewater Total organic carbon concentration (TOC)
Range (3,0 – 300,0) mg/l
Spectrophotometric method PB 24-LCK 385-386 issue 2 of 01.12.2010 | based on the Hach Lange cuvette test No. LCK 385 and LCK 386
13 Water, wastewater Free and total chlorine concentration
Range (0,10 – 1,5) mg/l
Spectrophotometric method PB 24-LCW 510 issue 5 of 26.11.2014 | based on the Hach Lange cuvette test No. LCW 510
14 Water, wastewater Iron concentration
Range (0,05 – 10) mg/l
Spectrophotometric method PB 24-LCK 521 issue 5 of 21.08.2014 | based on the Hach Lange cuvette test No. LCK 521
15 Water, wastewater, rainwater and snowmelt water Total suspended solids (TSS)
Range (2,0 – 5000) mg/l
Gravimetric method PN-EN 872:2007+Ap1:2007
16 Wastewater Sampling for chemical and physical testing
Temperature of the collected wastewater sample Range (4,0 – 40) °C
Manual method; Automatic method PN-ISO 5667-10:2021-11 | PN-77/C-04584
17 Wastewater Settleable solids
Range (0,1 – 10) ml/l
Volumetric method PN-72/C-04559/03
18 Wastewater Concentration of substances extractable with petroleum ether
Range (10 – 1000) mg/l
Gravimetric method PB-16 issue 4 of 21.08.2023
19 Water Sampling for chemical and physical testing Temperature of the water sample taken
Range (4,0 – 40) °C
PN-ISO 5667-5:2017-10 | PN-EN ISO 5667-6:2016-12 excluding cl. 7.5, 7.6, 8.2, 9.4 | PN-ISO 5667-11:2017-10 excluding cl. 5.2, 6.1.2, 6.2, 6.3 | PN-77/C-04584
20 Water intended for human consumption, well water, swimming pool water Sampling for microbiological testing PN-EN ISO 19458:2007
21 Water (including swimming pool water) Turbidity
Range (0,10 – 40) NTU
Nephelometric method PN-EN ISO 7027-1:2016-09 excluding cl. 5.4
22 Water intended for human consumption Manganese concentration
Range (0,015 – 1,0) mg/l
Spectrophotometric method PB 24-LCW 032 issue 7 of 21.08.2023 | based on the Hach Lange cuvette test No. LCW 032
23 Water intended for human consumption Total calcium and magnesium content (total hardness)
Range (1,0 – 20) dH Range (17,9 – 358) mg/l CaCO3
Spectrophotometric method PB 24-LCK 327 issue 4 of 25.09.2011 | based on the Hach Lange cuvette test No. LCK 327
24 Water intended for human consumption Colour
Range (2 – 200) mg/l Pt
Spectrophotometric method PB-23 issue 3 of 25.09.2011
25 Water intended for human consumption, water Electrical conductivity
Range (100 – 6000) μS/cm
Conductometric method PN-EN 27888:1999
26 Water Total calcium and magnesium content (total hardness)
Range (20 – 800) mg/l CaCO3
Titrimetric method PN-ISO 6059:1999
27 Water, water intended for human consumption Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004
28 Water, water intended for human consumption Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04
29 Water, water intended for human consumption Total viable count at 22°C Plate method (pour plate) PN-EN ISO 6222:2004
30 Water, water intended for human consumption, swimming pool water Total viable count at 36°C Plate method (pour plate) PN-EN ISO 6222:2004
31 Water, water intended for human consumption, swimming pool water Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266:2009
32 Water, water intended for human consumption, swimming pool water Count of bacteria of the genus Legionella
Matrix A Procedure 5 (medium BCYE), Procedure 7 (medium GVPC)
Membrane filtration method PN-EN ISO 11731:2017-08
33 Water, water intended for human consumption, swimming pool water Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04
34 Sewage sludge Sampling for chemical, physical, microbiological and biological testing PN-EN ISO 5667-13:2011
35 Sewage sludge Dry matter
Range (0,7 – 40) % Water content (calculated)
Gravimetric method PN-EN 15934:2013-02 Method A
36 Sewage sludge Loss on ignition of dry matter
Range (15 – 80) %
Gravimetric method PN-EN 15935:2022-01

Reference standards (48)

PB 24-LCK 138-338 issue 5 of 21.08.2014
PB 24-LCK 153-353 issue 2 of 01.12.2010
PB 24-LCK 302-304 issue 4 of 25.09.2011
PB 24-LCK 327 issue 4 of 25.09.2011
PB 24-LCK 339 issue 5 of 31.08.2022
PB 24-LCK 341 issue 4 of 25.09.2011
PB 24-LCK 348-350 issue 5 of 21.08.2014
PB 24-LCK 385-386 issue 2 of 01.12.2010
PB 24-LCK 521 issue 5 of 21.08.2014
PB 24-LCW 032 issue 7 of 21.08.2023
PB 24-LCW 510 issue 5 of 26.11.2014
PB-16 issue 4 of 21.08.2023
PB-23 issue 3 of 25.09.2011
PN-72/C-04559/03
PN-77/C-04584
PN-EN 15934:2013-02 Method A
PN-EN 15935:2022-01
PN-EN 1899-2:2002
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10523:2012
PN-EN ISO 11731:2017-08
PN-EN ISO 16266:2009
PN-EN ISO 19458:2007
PN-EN ISO 5667-13:2011
PN-EN ISO 5667-6:2016-12 excluding cl. 7.5, 7.6, 8.2, 9.4
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6222:2004
PN-EN ISO 7027-1:2016-09 excluding cl. 5.4
PN-EN ISO 7899-2:2004
PN-EN ISO 9308-1:2014-12 +A1:2017-04
PN-ISO 15705:2005
PN-ISO 5667-10:2021-11
PN-ISO 5667-11:2017-10 excluding cl. 5.2, 6.1.2, 6.2, 6.3
PN-ISO 5667-5:2017-10
PN-ISO 6059:1999
PN-ISO 9297:1994
based on the Hach Lange cuvette test No. LCK 138 and LCK 338
based on the Hach Lange cuvette test No. LCK 153 and LCK 353
based on the Hach Lange cuvette test No. LCK 302, LCK 303, LCK 304
based on the Hach Lange cuvette test No. LCK 327
based on the Hach Lange cuvette test No. LCK 339
based on the Hach Lange cuvette test No. LCK 341
based on Hach Lange cuvette tests No. LCK 348, LCK 349, LCK 350
based on the Hach Lange cuvette test No. LCK 385 and LCK 386
based on the Hach Lange cuvette test No. LCK 521
based on the Hach Lange cuvette test No. LCW 032
based on the Hach Lange cuvette test No. LCW 510

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/PL/AB%20862