🇵🇱 GRYFITLAB SP. Z O.O. PL
ConstructionEnvironmentMaterials & polymers
GRYFITLAB SP. Z O.O. is a laboratory accredited by PCA under number AB 818 (Goleniów, Poland). Its accreditation scope covers 57 test methods in the following areas: Construction, Environment, Materials & polymers. Test objects include: Machinery and equipment - noise, Rooms in residential, collective residence and public utility build…, General environment – noise from installations, equipment and indus…, Doors and door leaves (of wood, plastics, metals or mixed construct…. Most frequently used techniques: Direct measurement method, „In situ” method, Accurate method.
At a glance
- Accreditation number: PCA AB 818
- Methods in scope: 57
- Types of test objects: 41
- Techniques used: 9
- City: Goleniów, Poland
- Accreditation number
- AB 818
- Accreditation body
- PCA
- Address
- ZESPÓŁ LABORATORIÓW BADAWCZYCH GRYFITLAB, Łozienica, ul. Prosta 2, 72-100 Goleniów
- City
- Goleniów, Poland
What this laboratory tests (41)
- Machinery and equipment - noise — 6 methods
- Rooms in residential, collective residence and public utility buildings – noise from technical equipment penetrating into the rooms — 4 methods
- General environment – noise from installations, equipment and industrial plants — 3 methods
- Doors and door leaves (of wood, plastics, metals or mixed construction) — 2 methods
- Fire dampers — 2 methods
- General environment – noise from roads, railway lines, tram lines — 2 methods
- Internal walls, internal doors, floors — 2 methods
- Thermal releases — 2 methods
- Workplace environment – noise — 2 methods
- Building structures and elements - floors — 1 method
- Ceilings — 1 method
- Construction products – building and ventilation components and other objects with an area of less than 1 m2 — 1 method
- Construction products – external walls and their components, roofs, gates — 1 method
- Construction products – internal walls, internal doors, external walls, gates, external doors, windows, glazing, blinds, shutters, roof windows — 1 method
- Construction products – sound-absorbing materials and structures, objects and equipment forming interior furnishing elements — 1 method
- and 26 more
Analytical techniques used (9)
- Direct measurement method — 5 methods
- „In situ” method — 1 method
- Accurate method — 1 method
- Calculation method — 1 method
- Indicative method — 1 method
- Method: forced flow of air at a specified temperature — 1 method
- Method: forcing under specified conditions — 1 method
- Method: thermal excitation — 1 method
- Technical method — 1 method
Laboratory sections (2)
- Fire Resistance Tests Laboratory; Łozienica, ul. Prosta 2, 72-100 Goleniów — 29 methods
- Acoustics Laboratory; Łozienica, ul. Prosta 2, 72-100 Goleniów — 28 methods
Laboratory locations
- GRYFITLAB SP. Z O.O. (main site) — ul. Prosta 2, 72-100 Goleniów
- GRYFITLAB TESTING LABORATORIES GROUP — Łozienica, ul. Prosta 2, 72-100 Goleniów
- Acoustics Laboratory — Łozienica, ul. Prosta 2, 72-100 Goleniów
- Fire Testing Laboratory — Łozienica, ul. Prosta 2, 72-100 Goleniów
Certificate information
- Issue date
- 21.07.2026
- Issue no.
- 32
Accreditation scope — test methods (57)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Acoustics Laboratory; Łozienica, ul. Prosta 2, 72-100 Goleniów | |||||
| 1 | General environment – noise from roads, railway lines, tram lines | A-weighted equivalent sound level; A-weighted sound exposure level Range (24 – 135) dB |
Direct measurement method | Annex 3 to the Regulation of the Minister of the Environment of 16.06.2011 (Journal of Laws 2011 No. 140, item 824, Journal of Laws 2011 No. 288, item 1697) excluding cl. H | |
| 2 | General environment – noise from roads, railway lines, tram lines | A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) | Annex 3 to the Regulation of the Minister of the Environment of 16.06.2011 (Journal of Laws 2011 No. 140, item 824, Journal of Laws 2011 No. 288, item 1697) excluding cl. H | ||
| 3 | General environment – noise from installations, equipment and industrial plants | A-weighted equivalent sound pressure level Range (24 – 135) dB |
Direct measurement method | Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023 item 1706) | PN ISO 9613-2:2002 | |
| 4 | General environment – noise from installations, equipment and industrial plants | A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) | Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023 item 1706) | PN ISO 9613-2:2002 | ||
| 5 | General environment – noise from installations, equipment and industrial plants | Equivalent A-weighted sound level for the reference time T expressed by the indicators LAeqD and LAeqN | Calculation method | Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023 item 1706) | PN ISO 9613-2:2002 | |
| 6 | Workplace environment – noise | A-weighted equivalent sound level; A-weighted maximum sound level; C-weighted peak sound level Range (24 – 135) dB |
Direct measurement method | PN-N-01307:1994 | PN-EN ISO 9612:2011 excluding the method covering strategies 2 and 3 - cl. 10 and 11 | |
| 7 | Workplace environment – noise | Noise exposure level normalised to: (calculated) an 8-hour daily working time average weekly working time |
PN-N-01307:1994 | PN-EN ISO 9612:2011 excluding the method covering strategies 2 and 3 - cl. 10 and 11 | ||
| 8 | Rooms in residential, collective residence and public utility buildings – noise from technical equipment penetrating into the rooms | A-weighted equivalent sound level; A-weighted maximum sound level Range (24 – 135) dB |
Direct measurement method | PN-87/B-02156 | |
| 9 | Rooms in residential, collective residence and public utility buildings – noise from technical equipment penetrating into the rooms | A-weighted equivalent sound level for reference time T (calculated) | PN-87/B-02156 | ||
| 10 | Rooms in residential, collective residence and public utility buildings – noise from technical equipment penetrating into the rooms | A- and C-weighted equivalent sound level; A- and C-weighted maximum sound level Range (24 – 135) dB |
Direct measurement method | PN-EN ISO 10052:2007 | PN-EN ISO 10052:2021-12 | |
| 11 | Rooms in residential, collective residence and public utility buildings – noise from technical equipment penetrating into the rooms | Reference and standardized equivalent sound level from building service equipment (calculated) | PN-EN ISO 10052:2007 | PN-EN ISO 10052:2021-12 | ||
| 12 | Rooms in a building (except rooms with special acoustic properties, such as concert halls, rooms with a public address system) | Reverberation time Frequency range (100 ÷ 5000) Hz (measurement possible at 50, 63 and 80 Hz) |
PN-EN ISO 3382-2:2010 excluding cl. 5.3 | ||
| 13 | Construction products – sound-absorbing materials and structures, objects and equipment forming interior furnishing elements | Sound absorption coefficient in a reverberation chamber Frequency range (100 – 5000) Hz Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN ISO 354:2005 „N” | ||
| 14 | Machinery and equipment - noise | A-weighted sound pressure level; Sound pressure level in octave / 1/3 octave bands Range (50 – 10000) Hz Range (24 – 135) dB |
Accurate method | PN-EN ISO 3741:2011 excluding cl. 9.2 | |
| 15 | Machinery and equipment - noise | Sound power level (calculated) | PN-EN ISO 3741:2011 excluding cl. 9.2 | ||
| 16 | Machinery and equipment - noise | A-weighted sound pressure level Range (24 – 135) dB |
Technical method | PN-EN ISO 3743-2:2010 | |
| 17 | Machinery and equipment - noise | Sound power level (calculated) | PN-EN ISO 3743-2:2010 | ||
| 18 | Machinery and equipment - noise | A-weighted sound pressure level Range (24 – 135) dB |
Indicative method | PN-EN ISO 3746:2011+Ap1:2017-09 excluding cl. 8.4 | |
| 19 | Machinery and equipment - noise | Sound power level (calculated) | PN-EN ISO 3746:2011+Ap1:2017-09 excluding cl. 8.4 | ||
| 20 | Construction products – internal walls, internal doors, external walls, gates, external doors, windows, glazing, blinds, shutters, roof windows | Airborne sound insulation of building elements Frequency range (50 – 5000) Hz Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN ISO 10140-1:2021-10 „N” | PN-EN ISO 10140-2:2021-10 „N” | PN-EN ISO 10140-4:2021-10 „N” | PN-EN ISO 10140-5:2021-10 „N” | PN-EN 20140-3:1999 | PN-EN 20140-3:1999/A1:2007 | ASTM E90-09(2016) | ||
| 21 | Construction products – building and ventilation components and other objects with an area of less than 1 m2 | Airborne sound insulation of building elements Frequency range (50 – 5000) Hz Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN ISO 10140-1:2021-10 „N” | PN-EN ISO 10140-2:2021-10 „N” | PN-EN ISO 10140-4:2021-10 „N” | PN-EN ISO 10140-5:2021-10 „N” | PN-EN 20140-10:1994 | ASTM E90-09(2016) | ||
| 22 | Building structures and elements - floors | Impact sound insulation of floors Frequency range (100 ÷ 5000) Hz (measurement possible at 50, 63 and 80) Hz |
PN-EN ISO 140-7:2000 | PN-EN ISO 16283-2:2021-02 | ||
| 23 | Internal walls, internal doors, floors | Apparent airborne sound reduction index of building elements Frequency range (100 – 5000) Hz |
PN-EN ISO 140-4:2000 | ||
| 24 | Internal walls, internal doors, floors | Airborne sound insulation between rooms Frequency range (100 ÷ 5000) Hz (measurement possible at 50, 63 and 80 Hz) |
PN-EN ISO 16283-1:2014-05 | ||
| 25 | Construction products – external walls and their components, roofs, gates | Apparent airborne sound reduction index; Standardised sound pressure level difference; Normalised sound pressure level difference Frequency range (50 – 5000) Hz Frequency range (50 – 5000) Hz Frequency range (50 – 5000) Hz |
„In situ” method | PN-EN ISO 140-5:1999 | |
| 26 | Flat or curved glass panels (specially processed) | Airborne sound insulation Frequency range (50 – 5000) Hz Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN ISO 10140-1:2021-10 „N” | PN-EN ISO 10140-2:2021-10 „N” | PN-EN ISO 10140-4:2021-10 „N” | PN-EN ISO 10140-5:2021-10 „N” | PN-EN 20140-3:1999 | PN-EN 20140-3:1999/A1:2007 | ASTM E90-09(2016) | ||
| 27 | Insulating glass units | Airborne sound insulation Frequency range (50 – 5000) Hz Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN ISO 10140-1:2021-10 „N” | PN-EN ISO 10140-2:2021-10 „N” | PN-EN ISO 10140-4:2021-10 „N” | PN-EN ISO 10140-5:2021-10 „N” | PN-EN 20140-3:1999 | PN-EN 20140-3:1999/A1:2007 | ASTM E90-09(2016) | ||
| 28 | Windows with double-cavity glazing | Airborne sound insulation; Insulation indices RA2, RA1, RW | Test procedure PB-02, issue 1 of 31.07.2022 | ||
| Fire Resistance Tests Laboratory; Łozienica, ul. Prosta 2, 72-100 Goleniów | |||||
| 29 | Walls | Fire integrity, fire insulation, displacement, radiation Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 1364-1:2001 „N” | PN-EN 1364-1:2015-08 „N” | PN-EN 1363-1:2001 „N” | PN-EN 1363-1:2012 „N” | PN-EN 1363-1:2020-07 „N” | PN-EN 1363-2:2001 excluding P.7 „N” | ||
| 30 | Ceilings | Fire integrity, fire insulation Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 1364-2:2018-02 „N” | PN-EN 1363-1:2012 „N” | PN-EN 1363-1:2020-07 „N” | PN-EN 1363-2:2001 excluding P.7 „N” | PN-98/B-02875 | ||
| 31 | Curtain walling – full configuration | Fire integrity, fire insulation, displacement, radiation Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 1364-3:2014 – 03 „N” | PN-EN 1363-1:2012 „N” | PN-EN 1363-1:2020-07 „N” | PN-EN 1363-2:2001 excluding P.7 „N” | ||
| 32 | Curtain walling – partial configuration | Fire integrity, fire insulation, displacements Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 1364-4:2014-04 „N” | PN-EN 1363-1:2012 „N” | PN-EN 1363-1:2020-07 „N” | PN-EN 1363-2:2001 excluding P.7 „N” | ||
| 33 | Doors, windows and shutters | Fire integrity, fire insulation, self-closing ability, displacements, gaps, radiation Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 1634-1:2009 „N” | PN-EN 1634-1+A1:2018-03 „N” | PN-EN 1363-1 :2001 „N” | PN-EN 1363-1:2012 „N” | PN-EN 1363-1:2020-07 „N” | PN-EN 1363-2:2001 excluding P.7 „N” | ||
| 34 | Fire dampers | Fire integrity, fire insulation, fire smoke tightness Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 1366-2:2001 „N” | PN-EN 1366-2:2015-08 „N” | PN-EN 1363-1:2001 „N” | PN-EN 1363-1:2012 „N” | PN-EN 1363-1:2020-07 „N” | PN-EN 1363-2:2001 excluding P.7 „N” | ||
| 35 | Smoke control dampers in fire ventilation systems | Fire integrity, fire insulation, fire smoke tightness, reduction of cross-sectional area Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 1366-10+A1:2017-05 „N” | PN-EN 1366-10+A1:2025-03 „N” | PN-EN 1363-1:2012 „N” | PN-EN 1363-1:2020-07 „N” | PN-EN 1363-2:2001 excluding P.7 „N” | ||
| 36 | Penetration seals | Fire integrity, fire insulation Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 1366-3+A1:2025-04 „N” | PN-EN 1363-1:2012 „N” | PN-EN 1363-1:2020-07 „N” | PN-EN 1363-1:2001 „N” | PN-EN 1363-2:2001 excluding P.7 „N” | ||
| 37 | Floors and roofs | Fire integrity, fire insulation, fire load-bearing capacity Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 1365-2:2014-12 „N” | PN-EN 1363-1:2012 „N” | PN-EN 1363-1:2020-07 „N” | PN-EN 1363-2:2001 excluding P.7 „N” | ||
| 38 | Raised access floors and raised floors | Fire integrity, fire insulation, fire load-bearing capacity Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 1366-6:2006 „N” | PN-EN 1363-1:2012 „N” | PN-EN 1363-1:2020-07 „N” | PN-EN 1363-1:2001 „N” | PN-EN 1363-2:2001 excluding P.7 „N” | ||
| 39 | Smoke barriers | Temperature–time resistance; Smoke leakage Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 12101-1:2007 excluding cl. 6, 7, 8, 9, Annex B, E, ZA | PN-EN 1363-1:2012 „N” | PN-EN 1363-1:2020-07 „N” | PN-EN 1363-2:2001 excluding cl. 7 „N” | PN-EN 1634-3:2006+AC:2006 „N” | ||
| 40 | Light fire-resisting units, fire-resistant cabinets | Temperature rise inside the test specimen in °C Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 15659:2019-12 | PN-EN 1363-1:2012 „N” | PN-EN 1363-1:2020-07 „N” | PN-EN 1363-1:2001 „N” | PN-EN 1363-2:2001 excluding cl. 7 „N” | ||
| 41 | Storage cabinets for flammable liquids | Temperature rise inside the test specimen, self-closing, closing force, load-bearing capacity, aerotechnical test | PN-EN 14470-1:2023-12 | ||
| 42 | Thermal releases | Operating temperature Range (20 – 220) °C |
Method: thermal excitation | ISO 10294-4:2001 excluding Annex A | ISO 21925-1:2018-11 (Annex C) | |
| 43 | Thermal releases | Operational reliability Range (20 – 220) °C |
Method: forced flow of air at a specified temperature | ISO 10294-4:2001 excluding Annex A | ISO 21925-1:2018-11 (Annex C) | |
| 44 | Fire dampers | Correctness of the opening and closing cycles Voltage range (0 – 300) V Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
Method: forcing under specified conditions | PN-EN 15650:2010 Annex C | PN-EN 1366-10+A1:2017-05 | PN-EN 1366-10+A1:2025-03 „N” | |
| 45 | Smoke control doors and shutters | Smoke leakage, self-closing flow rate self-closing ability Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 1634-3:2006+AC:2006 „N” | ||
| 46 | Fire-resistant cabinets for the storage of data recorded on paper, magnetic media and diskettes | Temperature rise inside the test specimen [°C] | NT FIRE 017, edition 3, approved 2003-09 | ISO 834-1:1999 | ||
| 47 | Fire-resistant cabinets for the storage of lithium-ion batteries | Temperature rise inside and outside the test sample; Propagation | VDMA 24994:2024-08 | ||
| 48 | Non-mechanical fire barriers for ventilation systems | Fire integrity, Fire insulation Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 1366-12+A1:2020-04 | PN-EN 1363-1:2012 „N” | PN-EN 1363-1:2020-07 „N” | PN-EN 1363-2:2001 excluding cl. 7 „N” | PN-EN 1366-2:2015-08 „N” | ||
| 49 | Hinged doors with closing devices | Resistance to repeated opening and closing | PN-EN 1191:2013-06 | ||
| 50 | Doors and door leaves (of wood, plastics, metals or mixed construction) | Resistance of doors to vertical loads | PN-EN 947:2000 | ||
| 51 | Doors and door leaves (of wood, plastics, metals or mixed construction) | Operating forces | PN-EN 12046-2:2001 | ||
| 52 | Doors, shutters, openable windows, gates, movable curtains | Self-closing; Ability to release; Durability of self-closing | PN-EN 16034:2014-11 | ||
| 53 | Ventilation grilles | Fire integrity, fire insulation, radiation Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 1364-5:2017-08 | PN-EN 1363-1:2012 „N” | PN-EN 1363-1:2020-07 „N” | PN-EN 1363-2:2001 excluding cl. 7 | ||
| 54 | Facade claddings | Effectiveness of fixing under fire conditions | Test procedure PB-01 issue 1 of 01.09.2021 | ||
| 55 | Service installations – linear joint seals | Fire resistance | PN-EN 1366-4:2021-07 excluding Annex B | ||
| 56 | Construction products and materials | Sampling | PN-83/N-03010 | NB-CPR/15/639 | ||
| 57 | Fire resistance tests for non-loadbearing elements - Part 6: Cavity barriers | Fire integrity, fire insulation | PN-EN 1364-6:2025-07 | ||
Reference standards (71)
ASTM E90-09(2016)
ISO 10294-4:2001 excluding Annex A
ISO 21925-1:2018-11 (Annex C)
ISO 834-1:1999
NB-CPR/15/639
NT FIRE 017, edition 3, approved 2003-09
PN ISO 9613-2:2002
PN-83/N-03010
PN-87/B-02156
PN-98/B-02875
PN-EN 1191:2013-06
PN-EN 12046-2:2001
PN-EN 12101-1:2007 excluding cl. 6, 7, 8, 9, Annex B, E, ZA
PN-EN 1363-1 :2001 „N”
PN-EN 1363-1:2001 „N”
PN-EN 1363-1:2012 „N”
PN-EN 1363-1:2020-07 „N”
PN-EN 1363-2:2001 excluding P.7 „N”
PN-EN 1363-2:2001 excluding cl. 7
PN-EN 1363-2:2001 excluding cl. 7 „N”
PN-EN 1364-1:2001 „N”
PN-EN 1364-1:2015-08 „N”
PN-EN 1364-2:2018-02 „N”
PN-EN 1364-3:2014 – 03 „N”
PN-EN 1364-4:2014-04 „N”
PN-EN 1364-5:2017-08
PN-EN 1364-6:2025-07
PN-EN 1365-2:2014-12 „N”
PN-EN 1366-10+A1:2017-05
PN-EN 1366-10+A1:2017-05 „N”
PN-EN 1366-10+A1:2025-03 „N”
PN-EN 1366-12+A1:2020-04
PN-EN 1366-2:2001 „N”
PN-EN 1366-2:2015-08 „N”
PN-EN 1366-3+A1:2025-04 „N”
PN-EN 1366-4:2021-07 excluding Annex B
PN-EN 1366-6:2006 „N”
PN-EN 14470-1:2023-12
PN-EN 15650:2010 Annex C
PN-EN 15659:2019-12
PN-EN 16034:2014-11
PN-EN 1634-1+A1:2018-03 „N”
PN-EN 1634-1:2009 „N”
PN-EN 1634-3:2006+AC:2006 „N”
PN-EN 20140-10:1994
PN-EN 20140-3:1999
PN-EN 20140-3:1999/A1:2007
PN-EN 947:2000
PN-EN ISO 10052:2007
PN-EN ISO 10052:2021-12
PN-EN ISO 10140-1:2021-10 „N”
PN-EN ISO 10140-2:2021-10 „N”
PN-EN ISO 10140-4:2021-10 „N”
PN-EN ISO 10140-5:2021-10 „N”
PN-EN ISO 140-4:2000
PN-EN ISO 140-5:1999
PN-EN ISO 140-7:2000
PN-EN ISO 16283-1:2014-05
PN-EN ISO 16283-2:2021-02
PN-EN ISO 3382-2:2010 excluding cl. 5.3
PN-EN ISO 354:2005 „N”
PN-EN ISO 3741:2011 excluding cl. 9.2
PN-EN ISO 3743-2:2010
PN-EN ISO 3746:2011+Ap1:2017-09 excluding cl. 8.4
PN-EN ISO 9612:2011 excluding the method covering strategies 2 and 3 - cl. 10 and 11
PN-N-01307:1994
Test procedure PB-01 issue 1 of 01.09.2021
Test procedure PB-02, issue 1 of 31.07.2022
VDMA 24994:2024-08
Annex 3 to the Regulation of the Minister of the Environment of 16.06.2011 (Journal of Laws 2011 No. 140, item 824, Journal of Laws 2011 No. 288, item 1697) excluding cl. H
Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023 item 1706)