🇵🇱 GŁÓWNY INSPEKTORAT OCHRONY ŚRODOWISKA PL

PCA AB 805 • Warszawa, Poland • 78 methods

Water & wastewaterEnvironment

GŁÓWNY INSPEKTORAT OCHRONY ŚRODOWISKA is a laboratory accredited by PCA under number AB 805 (Warszawa, Poland). Its accreditation scope covers 78 test methods in the following areas: Water & wastewater, Environment. Test objects include: Water, wastewater, Water, Environment: – electromagnetic field in the vicinity of radiocommun…, General environment – noise from installations, equipment and indus…. Most frequently used techniques: Titrimetric method, Spectrophotometric method, Gravimetric method.

At a glance

  • Accreditation number: PCA AB 805
  • Methods in scope: 78
  • Types of test objects: 6
  • Techniques used: 16
  • City: Warszawa, Poland
Accreditation number
AB 805
Accreditation body
PCA
Address
ul. Chmielna 132/134, 00-805 Warszawa, CENTRALNE LABORATORIUM BADAWCZE, ODDZIAŁ W OLSZTYNIE
City
Warszawa, Poland

What this laboratory tests (6)

Analytical techniques used (16)

Laboratory locations

Certificate information

Issue date
02.07.2025
Issue no.
25

Accreditation scope — test methods (78)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Water, wastewater Total suspended solids (TSS)
Range (2,0 – 1000) mg/l
Gravimetric method P N-EN 872:2007+Ap1:2007
2 Water, wastewater Dissolved oxygen concentration
Range (0,2 – 20,0) mg/l O2
Titrimetric method PN-EN 25813:1997
3 Water, wastewater Biochemical oxygen demand
BOD5 Range (0,5 – 6,0) mg/l O2
Titrimetric method PN-EN 1899-2:2002
4 Water, wastewater Biochemical oxygen demand
BOD5 Range (1 – 6000) mg/l O2
Titrimetric method PN-EN ISO 5815-1:2019-12
5 Water, wastewater Chemical oxygen demand
COD-Cr Range (6,0 – 1000) mg/l O2
Spectrophotometric method PN-ISO 15705:2005
6 Water, wastewater Ammonium nitrogen concentration
Range (1,0 – 100) mg/l
Titrimetric method PN-ISO 5664:2002
7 Water, wastewater Nitrite nitrogen concentration
Range (0,0020 – 10) mg/l
Spectrophotometric method PN-EN 26777:1999
8 Water, wastewater Kjeldahl nitrogen concentration
Range (2,0 – 500) mg/l
Titrimetric method PN-EN 25663:2001
9 Water, wastewater Total nitrogen concentration (calculated) PB-01/OL issue 1 of 01.02.2020
10 Water, wastewater Total phosphorus concentration
Range (0,010 – 100) mg/l
Spectrophotometric method PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 cl. 7
11 Water, wastewater Chloride concentration
Range (4,0 – 5050) mg/l
Titrimetric method PN-ISO 9297:1994
12 Water, wastewater Total organic carbon concentration (TOC)
Range (1,0 – 1000) mg/l
High-temperature combustion with IR detection PN-EN 1484:1999
13 Water, wastewater Ammonium nitrogen concentration
Range (0,025 – 100) mg/l
Spectrophotometric method PN-ISO 7150-1:2002
14 Water, wastewater Anion concentrations
chlorides (2,0 – 200) mg/l sulfates (2,5 – 500) mg/l nitrite nitrogen (0,050 – 50) mg/l nitrate nitrogen (0,050 – 50) mg/l fluorides (0,25 – 50) mg/l
Ion chromatography with conductometric detection (IC-CD) PN-EN ISO 10304-1:2009+AC:2012
15 Water, wastewater Substances extractable with petroleum ether
Range (5,0 – 200) mg/l
Gravimetric method PN-86/C-04573-01
16 Water Total dissolved solids (TDS)
Range (100 – 5000) mg/l
Gravimetric method PN-EN 15216:2022-03
17 Water Calcium concentration
Range (10 – 200) mg/l
Titrimetric method PN-ISO 6058:1999
18 Water Total content of calcium and magnesium (total hardness)
Range (30 – 500) mg/l CaCO3
Titrimetric method PN-ISO 6059:1999
19 Water Total alkalinity
Range (20 – 300) mg/l CaCO3
Titrimetric method PN-EN ISO 9963-1:2001+Ap1:2004
20 Water Colour
Range (2 – 250) mg/l Pt
Spectrophotometric method PN-EN ISO 7887:2012
21 Water Permanganate index
Range (1,0 – 100) mg/l O2
Titrimetric method P N-EN ISO 8467:2001
22 Water Phosphate phosphorus concentration
Range (0,005 – 50) mg/l
Spectrophotometric method PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 cl. 4
23 Water, wastewater Dissolved oxygen concentration
Range (0,2 – 20) mg/l O2
Titrimetric method PN-EN 25813:1997 | PN-ISO 5813:1997
24 Water, wastewater Biochemical oxygen demand
BOD5 Range (0,5 – 6,0) mg/l O2
Titrimetric method PN-EN 1899-2:2002
25 Water, wastewater Biochemical oxygen demand
BOD5 Range (1 – 6000) mg/l O2
Titrimetric method PN-EN ISO 5815-1:2019-12
26 Water, wastewater Chemical oxygen demand
COD-Cr Range (6,0 – 1000) mg/l O2
Spectrophotometric method PN-ISO 15705:2005
27 Water, wastewater Ammonium nitrogen concentration
Range (1,0 – 100) mg/l
Titrimetric method PN-ISO 5664:2002
28 Water, wastewater Ammonium nitrogen concentration, Range; (0,025 – 100) mg/l Spectrophotometric method PN-ISO 7150-1:2002
29 Water, wastewater Nitrite nitrogen concentration
Range (0,0020 – 10) mg/l
Spectrophotometric method PN-EN 26777:1999
30 Water, wastewater Kjeldahl nitrogen concentration
Range (2,0 – 500) mg/l
Titrimetric method PN-EN 25663:2001
31 Water, wastewater Total nitrogen concentration (calculated) PB-01/OL issue 1 of 01.02.2020
32 Water, wastewater Total suspended solids (TSS)
Range (2,0 – 500) mg/l
Gravimetric method PN-EN 872:2007+Ap1:2007
33 Water, wastewater Total phosphorus concentration
Range (0,010 – 100) mg/l
Spectrophotometric method PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 cl. 7
34 Wastewater Concentration of polycyclic
aromatic hydrocarbons (PAH) benzo(b)fluoranthene Range (0,0010 – 0,040) μg/l benzo(k)fluoranthene (0,0010 – 0,050) μg/l benzo(a)pyrene (0,000050 – 0,050) μg/l benzo(g,h,i)perylene (0,00040 – 0,040) μg/l indeno (1,2,3-cd)pyrene (0,00020 – 0,040) μg/l dibenzo(a,h)anthracene (0,0010 – 0,050) μg/l Sum of PAH (calculated)
High-performance liquid chromatography with fluorescence detection (HPLC-FLD) PN-EN ISO 17993:2005
35 Water Colour
Range (2 – 250) mg/l Pt
Spectrophotometric method PN-EN ISO 7887:2012
36 Water Total dissolved solids (TDS)
Range (100 – 2400) mg/l
Gravimetric method PN-EN 15216:2022-03
37 Water Total alkalinity
Range (20 – 500) mg/l CaCO3
Titrimetric method PN-EN ISO 9963-1:2001+Ap1:2004
38 Water Concentration of polycyclic
aromatic hydrocarbons (PAH) naphthalene (0,010 – 0,20) μg/l anthracene (0,0010 – 0,010) μg/l fluoranthene (0,0010 – 0,080) μg/l benzo(b)fluoranthene Range (0,0010 – 0,040) μg/l benzo(k)fluoranthene (0,0010 – 0,050) μg/l benzo(a)pyrene (0,000050 – 0,050) μg/l benzo(g,h,i)perylene (0,00040 – 0,040) μg/l indeno (1,2,3-cd)pyrene (0,00020 – 0,040) μg/l dibenzo(a,h)anthracene (0,0010 – 0,050) μg/l Sum of PAH (calculated)
High-performance liquid chromatography with fluorescence detection (HPLC-FLD) PN-EN ISO 17993:2005
39 Water Calcium concentration
Range (10 – 100) mg/l
Titrimetric method PN-ISO 6058:1999
40 Water Total content of calcium and magnesium (total hardness)
Range (30 – 350) mg/l CaCO3
Titrimetric method PN-ISO 6059:1999
41 Water Permanganate index
Range (1,0 – 1000) mg/l O2
Titrimetric method PN-EN ISO 8467:2001
42 Water Phosphate phosphorus concentration
Range (0,005 – 50) mg/l
Spectrophotometric method PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 cl. 4
43 Water, wastewater Total suspended solids (TSS)
Range (2,0 – 1000) mg/l
Gravimetric method PN-EN 872:2007+Ap1:2007
44 Water, wastewater Dissolved oxygen concentration
Range (0,2 – 20) mg/l O2
Titrimetric method PN-EN 25813:1997
45 Water, wastewater Dissolved oxygen concentration
Range (0,2 – 20) mg/l O2
Electrochemical method PN-EN ISO 5814:2013-04
46 Water, wastewater Biochemical oxygen demand
BOD5 Range (0,5 – 6,0) mg/l O2
Titrimetric method PN-EN 1899-2:2002
47 Water, wastewater Biochemical oxygen demand
BOD5 Range (0,5 – 6,0) mg/l O2
Electrochemical method PN-EN 1899-2:2002
48 Water, wastewater Biochemical oxygen demand
BOD5 Range (1,0 – 6000) mg/l O2
Electrochemical method PN-EN ISO 5815-1:2019-12
49 Water, wastewater Ammonium nitrogen concentration
Range (1,0 – 200) mg/l
Titrimetric method PN-ISO 5664:2002
50 Water, wastewater Ammonium nitrogen concentration
Range (0,025 – 100) mg/l
Spectrophotometric method PN-ISO 7150-1:2002
51 Water, wastewater Nitrite nitrogen concentration
Range (0,0020 – 70) mg/l
Spectrophotometric method PN-EN 26777:1999
52 Water, wastewater Kjeldahl nitrogen concentration
Range (2,0 – 500) mg/l
Titrimetric method PN-EN 25663:2001
53 Water, wastewater Total nitrogen concentration (calculated ) PB-01/OL issue 1 of 01.02.2020
54 Water, wastewater Total phosphorus concentration
Range (0,010 – 100) mg/l
Continuous flow analysis (CFA) with spectrophotometric detection PN-EN ISO 15681-2:2019-02
55 Water, wastewater Orthophosphate concentration
Range (0,015-153) mg/l PO4 Phosphate phosphorus concentration Range (0,005-50) mg/l
Continuous flow analysis (CFA) with spectrophotometric detection PN-EN ISO 15681-2:2019-02
56 Water, wastewater Chemical oxygen demand
COD-Cr Range (6,0 – 10000) mg/l O2
Spectrophotometric method PN-ISO 15705:2005
57 Water, wastewater Anion concentrations
chlorides (2,0 – 500) mg/l sulfates (2,5 – 500) mg/l nitrate nitrogen (0,050 – 100) mg/l fluorides (0,25 – 10) mg/l
Ion chromatography with conductometric detection (IC-CD) PN-EN ISO 10304-1:2009+AC:2012
58 Water, wastewater Metal concentrations
arsenic (0,010 – 10) mg/l boron (0,10 – 100) mg/l barium (0,010 – 100) mg/l selenium (0,010 – 1000) mg/l copper (0,0020 – 100) mg/l lead (0,0050 – 100) mg/l nickel (0,0010 – 100) mg/l manganese (0,0010 – 100) mg/l iron (0,0020 – 100) mg/l zinc (0,010 – 50) mg/l cadmium (0,0010 – 10) mg/l chromium (0,0020 – 50) mg/l aluminium (0,010 – 100) mg/l silver (0,0010 – 1,0) mg/l vanadium (0,010 – 10) mg/l
Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN ISO 11885:2009
59 Water, wastewater Mineral oil index
Range (0,050 – 1000) mg/l
Gas chromatography with flame ionization detection (GC-FID) PN-EN ISO 9377-2:2003
60 Water Total alkalinity
Range (20 – 500) mg/l CaCO3
Titrimetric method PN-EN ISO 9963-1:2001+Ap1:2004
61 Water Total dissolved solids (TDS)
Range (100 – 5000) mg/l
Gravimetric method PN-EN 15216:2022-03
62 Water Permanganate index
Range (1,0 – 200) mg/l O2
Titrimetric method PN-EN ISO 8467:2001
63 Water Sodium concentration
Range (0,040 – 40) mg/l
Flame atomic absorption spectrometry (FAAS) PN-ISO 9964-1:1994+Ap1:2009
64 Water Element concentration
Magnesium (1,0 – 200) mg/l Calcium (1,0 – 1000) mg/l
Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN ISO 11885:2009
65 Water Potassium concentration
Range (0,020 – 40) mg/l
Flame atomic absorption spectrometry (FAAS) PN-ISO 9964-2:1994
66 Water Total hardness (calculated) PB-07/OL issue 1 of 01.02.2020
67 Water Colour
Range (2 – 250) mg/l Pt
Spectrophotometric method PN-EN ISO 7887:2012
68 Soil Content of petroleum hydrocarbons C12-C35
Range ( 3 0 – 3 0 0 0 ) m g / k g
Gas chromatography with flame ionization detection (GC-FID) PN-EN ISO 16703:2011
69 Water Sampling for chemical and physical testing Temperature of water / of the water sample taken
Range (0,0 – 30,0) °C
PN-ISO 5667-4:2017-10 | PN-EN ISO 5667-6:2016-12 | PN-EN ISO 5667-11:2017-10 excluding cl. 5.2 and 6.2 | PN-77/C-04584
70 Water Dissolved oxygen concentration
Range (0,1 – 20,0) mg/l O2
Optical method ISO 17289:2014
71 Wastewater Sampling for chemical and physical testing
Temperature of wastewater /of the collected wastewater sample Range (0,0 – 50,0) °C
Manual method; Automatic method PN-ISO 5667-10:2021-11 | PN-77/C-04584
72 Soil Sampling for chemical and physical testing PN-ISO 10381-4:2007 | PN-ISO 10381-5:2009
73 Water, wastewater pH
Range 4,0 – 10,0
Potentiometric method PN-EN ISO 10523:2012
74 Water, wastewater Electrical conductivity
Range (100 – 20000) μS/cm
Conductometric method PN-EN 27888:1999
75 General environment – noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level
Range (25 – 135) dB
Direct measurement method Annex 7 to the Regulation of the Minister of Climate and Environment of 7.09.2021 (consolidated text Journal of Laws of 2023, item 1706) excluding cl. F
76 General environment – noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Annex 7 to the Regulation of the Minister of Climate and Environment of 7.09.2021 (consolidated text Journal of Laws of 2023, item 1706) excluding cl. F
77 Environment: – electromagnetic field in the vicinity of radiocommunication installations: broadband measurements
in the frequency range from 10 MHz up to 40 GHz Range (0,2 – 300) V/m
Direct measurement method Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630)
78 Environment: – electromagnetic field in the vicinity of radiocommunication installations: broadband measurements Magnetic field strength:
in the frequency range from 10 MHz up to 40 GHz (calculated)
Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630)

Reference standards (47)

ISO 17289:2014
P N-EN 872:2007+Ap1:2007
P N-EN ISO 8467:2001
PB-01/OL issue 1 of 01.02.2020
PB-01/OL issue 1 of 01.02.2020
PB-07/OL issue 1 of 01.02.2020
PN-77/C-04584
PN-86/C-04573-01
PN-EN 1484:1999
PN-EN 15216:2022-03
PN-EN 1899-2:2002
PN-EN 25663:2001
PN-EN 25813:1997
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10304-1:2009+AC:2012
PN-EN ISO 10523:2012
PN-EN ISO 11885:2009
PN-EN ISO 15681-2:2019-02
PN-EN ISO 16703:2011
PN-EN ISO 17993:2005
PN-EN ISO 5667-11:2017-10 excluding cl. 5.2 and 6.2
PN-EN ISO 5667-6:2016-12
PN-EN ISO 5814:2013-04
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 cl. 4
PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 cl. 7
PN-EN ISO 7887:2012
PN-EN ISO 8467:2001
PN-EN ISO 9377-2:2003
PN-EN ISO 9963-1:2001+Ap1:2004
PN-ISO 10381-4:2007
PN-ISO 10381-5:2009
PN-ISO 15705:2005
PN-ISO 5664:2002
PN-ISO 5667-10:2021-11
PN-ISO 5667-4:2017-10
PN-ISO 5813:1997
PN-ISO 6058:1999
PN-ISO 6059:1999
PN-ISO 7150-1:2002
PN-ISO 9297:1994
PN-ISO 9964-1:1994+Ap1:2009
PN-ISO 9964-2:1994
Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630)
Annex 7 to the Regulation of the Minister of Climate and Environment of 7.09.2021 (consolidated text Journal of Laws of 2023, item 1706) excluding cl. F

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/PL/AB%20805