🇵🇱 PRACOWNIA BADAŃ ŚRODOWISKA PRACY PL

PCA AB 802 • Jawor, Poland • 139 methods

EnvironmentMaterials & polymers

PRACOWNIA BADAŃ ŚRODOWISKA PRACY is a laboratory accredited by PCA under number AB 802 (Jawor, Poland). Its accreditation scope covers 139 test methods in the following areas: Environment, Materials & polymers. Test objects include: Workplace environment – air – air samples, Workplace environment – non-laser optical radiation, Workplace environment – air, Workplace environment – electric lighting. Most frequently used techniques: Gas chromatography with flame ionization detection (GC-FID), Microwave plasma atomic emission spectrometry (MP-AES), Direct measurement method.

At a glance

  • Accreditation number: PCA AB 802
  • Methods in scope: 139
  • Types of test objects: 14
  • Techniques used: 19
  • City: Jawor, Poland
Accreditation number
AB 802
Accreditation body
PCA
Address
„HIGIENA PRACY” MAREK SMOCZYŃSKI, ul. Jasna 3B/7,59-400 Jawor, ul. Starojaworska 29B/3, 59-400 Jawor (Działalność techniczna)
City
Jawor, Poland

What this laboratory tests (14)

Analytical techniques used (19)

Laboratory locations

Certificate information

Issue date
04.05.2026
Issue no.
24

Accreditation scope — test methods (139)

No. Test object Methodology / Parameters Technique Reference document
Working Environment Testing Laboratory "Higiena Pracy" Marek Smoczyński
1 Workplace environment – air Sampling for the assessment of occupational exposure to:
dust agents – inhalable fraction – respirable fraction organic substances, including – inhalable fraction metals and their compounds, including – inhalable fraction – respirable fraction asbestos – respirable fibres man-made mineral fibres excluding refractory ceramic fibres – respirable fibres silicon carbide fibrous – respirable fibres refractory ceramic fibres refractory ceramic fibres mixed with other man-made mineral fibres
Personal dosimetry method PN-Z-04008-7:2002 + Az1:2004
2 Workplace environment – air Sampling for the assessment of occupational exposure to:
inorganic substances, including – inhalable fraction – respirable fraction – thoracic fraction
Stationary method; Personal dosimetry method PN-Z-04008-7:2002 + Az1:2004
3 Workplace environment – air Exposure index (calculated) PN-Z-04008-7:2002 + Az1:2004
4 Workplace environment – air Concentration / content of crystalline silica – quartz, cristobalite – respirable fraction
Range (0,0098–3,0) mg/m3 Range (0,00773 – 0,5) mg in the sample
Fourier transform infrared spectrometry (FT-IR) Principles and Methods of Assessing the Working Environment 2012, No. 4 (74), pp. 117–130
5 Workplace environment – air Concentration of harmful dust agents – inhalable fraction
apatites and phosphorites petroleum bitumen portland cement titanium dioxide natural graphite synthetic graphite kaolin amorphous and synthetic silica wood dusts flour dusts dusts not classified according to toxicity organic dusts of animal and plant origin, excluding wood and flour dusts carbon black calcium sulfate (VI) (gypsum) talc coal (hard, brown) calcium magnesium carbonate (dolomite) silicon carbide, non-fibrous silicon carbide, fibrous man-made mineral fibres excluding refractory ceramic fibres Range (0,040 -17,36) mg/m3
Gravimetric method PN-Z-04507:2022-05
6 Workplace environment – air Concentration of harmful dust agents – respirable fraction
apatites and phosphorites portland cement natural graphite amorphous and synthetic silica organic dusts of animal and plant origin, excluding wood and flour dusts diesel engine exhaust talc coal (hard, brown) Range (0,031 - 20) mg/m3
Gravimetric method PN-Z-04508:2022-05
7 Workplace environment – air – air samples Concentration / content of iron oxides calculated as Fe iron(III) oxide iron(II) oxide triiron tetraoxide – inhalable fraction
Range (0,035 – 28,6) mg/m3 Range (0,025 – 20,6) mg in the sample – respirable fraction Range (0,032 – 26,0) mg/m3 Range (0,025 – 20,6) mg in the sample
Microwave plasma atomic emission spectrometry (MP-AES) PB-06/08 issue 3 of 06.01.2025
8 Workplace environment – air – air samples Concentration / content of manganese and its inorganic compounds calculated as Mn
inhalable fraction Range (0,0021– 1,04) mg/m3 Range (0,0015 – 0,75) mg in the sample respirable fraction Range (0,0019 – 0,95) mg/m3 Range (0,0015 – 0,75) mg in the sample
Microwave plasma atomic emission spectrometry (MP-AES) PB-06/08 issue 3 of 06.01.2025
9 Workplace environment – air – air samples Concentration / content of copper and its inorganic compounds expressed as Cu
Range (0,0069 – 4,00) mg/m3 Range (0,0050 – 2,88) mg in the sample
Microwave plasma atomic emission spectrometry (MP-AES) PB-06/08 issue 3 of 06.01.2025
10 Workplace environment – air – air samples Concentration/ content of lead and its inorganic compounds - calculated as Pb
inhalable fraction Range (0,00174 – 2,78) mg/m3 Range (0,0013 – 2,00) mg in the sample
Microwave plasma atomic emission spectrometry (MP-AES) PB-06/08 issue 3 of 06.01.2025
11 Workplace environment – air – air samples Concentration / content of sodium hydroxide
Range (0,0060 – 6,04) mg/m3 Range (0,0043 – 4,35) mg in the sample
Microwave plasma atomic emission spectrometry (MP-AES) PB-06/08 issue 3 of 06.01.2025
12 Workplace environment – air – air samples Concentration / content of potassium hydroxide
Range (0,0050 – 4,99) mg/m3 Range (0,0036 – 3,59) mg in the sample
Microwave plasma atomic emission spectrometry (MP-AES) PB-06/08 issue 3 of 06.01.2025
13 Workplace environment – air – air samples Concentration / content of metallic chromium, chromium compounds: chromium (II), chromium (III), chromium (VI) – calculated as Cr
Range (0,0174 – 1,75) mg/m3 Range (0,0125 – 1,26) mg in the sample
Microwave plasma atomic emission spectrometry (MP-AES) PB-06/08 issue 3 of 06.01.2025
14 Workplace environment – air – air samples Content of metallic chromium, chromium (II) compounds – calculated as, Cr (II), chromium (III) compounds – calculated as Cr (III) Calculation method PB-06/32 issue 1 of 20.11.2023
15 Workplace environment – air – air samples Concentration / content of metallic nickel
Range (0,0014 – 1,74) mg/m3 Range (0,00075 - 1,25) mg in the sample
Microwave plasma atomic emission spectrometry (MP-AES) PB-06/08 issue 3 of 06.01.2025
16 Workplace environment – air – air samples Concentration / content of nickel compounds calculated as Ni
inhalable fraction Range (0,0014 – 1,74) mg/m3 Range (0,00075 - 1,25) mg in the sample respirable fraction Range (0,00095 – 1,58) mg/m3 Range (0,00075 - 1,25) mg in the sample
Microwave plasma atomic emission spectrometry (MP-AES) PB-06/08 issue 3 of 06.01.2025
17 Workplace environment – air – air samples Concentration / content of arsenic and its inorganic compounds expressed as As
inhalable fraction Range (0,00035 – 0,087) mg/m3 Range (0,00025 – 0,063) mg in the sample
Microwave plasma atomic emission spectrometry (MP-AES) PB-06/08 issue 3 of 06.01.2025
18 Workplace environment – air – air samples Concentration / content of zinc dichloride – inhalable fraction
Range (0,058 – 6,94) mg/m3 Range (0,042 – 5,00) mg in the sample
Microwave plasma atomic emission spectrometry (MP-AES) PB-06/08 issue 3 of 06.01.2025
19 Workplace environment – air – air samples Concentration / content of zinc oxide calculated as Zn – inhalable fraction
Range (0,0069 – 14,5) mg/m3 Range (0,0050 – 10,4) mg in the sample
Microwave plasma atomic emission spectrometry (MP-AES) PB-06/08 issue 3 of 06.01.2025
20 Workplace environment – air – air samples Concentration/ content of silver – inhalable fraction Concentration / content of silver
insoluble compounds Range (0,0024 – 3,47) mg/m3 Range (0,0018 – 2,50) mg in the sample- soluble compounds Range (0,00097 – 3,47) mg/m3 Range (0,00070 – 2,50) mg in the sample
Microwave plasma atomic emission spectrometry (MP-AES) PB-06/08 issue 3 of 06.01.2025
21 Workplace environment – air – air samples Concentration of cadmium and its inorganic compounds calculated as Cd
inhalable fraction Range (0,000097– 0,28) mg/m3 Range (0,00007– 0,20) mg in the sample
Microwave plasma atomic emission spectrometry (MP-AES) PB-06/08 issue 3 of 06.01.2025
22 Workplace environment – air – air samples Concentration / content of tin and its inorganic compounds, except stannane, expressed as Sn
inhalable fraction Range (0,17– 4,00) mg/m3 Range (0,12 – 2,88) mg in the sample
Microwave plasma atomic emission spectrometry (MP-AES) PB-06/08 issue 3 of 06.01.2025
23 Workplace environment – air – air samples Concentration / content of metallic aluminium, aluminium powder Concentration of aluminium hydroxide, aluminium trioxide, expressed as Al
inhalable fraction Range (0,069 – 5,00) mg/m3 Range (0,050 – 3,60) mg in the sample respirable fraction Range (0,063 – 4,54) mg/m3 Range (0,050 – 3,60) mg in the sample
Microwave plasma atomic emission spectrometry (MP-AES) PB-06/08 issue 3 of 06.01.2025
24 Workplace environment – air – air samples Concentration/ content of cobalt and its inorganic compounds calculated as Co
Range (0,0017– 1,04) mg/m3 Range (0,0013 – 0,75) mg in the sample
Microwave plasma atomic emission spectrometry (MP-AES) PB-06/08 issue 3 of 06.01.2025
25 Workplace environment – air – air samples Concentration/ content of magnesium oxide – inhalable fraction
Range (0,0060 – 15,0) mg/m3 Range (0,0043 – 10,8) mg in the sample
Microwave plasma atomic emission spectrometry (MP-AES) PB-06/08 issue 3 of 06.01.2025
26 Workplace environment – air – air samples Concentration/ content of calcium oxide
inhalable fraction Range (0,024 – 25,0) mg/m3 Range (0,018 – 18,0) mg in the sample respirable fraction Range (0,022 – 22,7) mg/m3 Range (0,018 – 18,0) mg in the sample
Microwave plasma atomic emission spectrometry (MP-AES) PB-06/08 issue 3 of 06.01.2025
27 Workplace environment – air – air samples Concentration/ content of calcium hydroxide
inhalable fraction Range (0,032 – 25,0) mg/m3 Range (0,023 – 18,00) mg in the sample respirable fraction Range (0,029 – 22,7) mg/m3 Range (0,023 – 18,0) mg in the sample
Microwave plasma atomic emission spectrometry (MP-AES) PB-06/08 issue 3 of 06.01.2025
28 Workplace environment – air – air samples Concentration/ content of calcium carbonate
inhalable fraction Range (0,043 – 25,0) mg/m3 Range (0,031 – 18,0) mg in the sample
Microwave plasma atomic emission spectrometry (MP-AES) PB-06/08 issue 3 of 06.01.2025
29 Workplace environment – air – air samples Concentration/ content of antimony and its inorganic compounds, except stibine - calculated as Sb
Range (0,0001 – 3,00) mg/m3 Range (0,0001 – 2,16) mg in the sample
Microwave plasma atomic emission spectrometry (MP-AES) PB-06/08 issue 3 of 06.01.2025
30 Workplace environment – air – air samples Concentration/ content of titanium and its compounds - calculated as Ti
Range (0,0347 – 26,0) mg/m3 Range (0,0250 – 18,7) mg in the sample
Microwave plasma atomic emission spectrometry (MP-AES) PB-06/08 issue 3 of 06.01.2025
31 Workplace environment – air – air samples Concentration/ content of selenium and its compounds, except selane - calculated as Se
Range (0,00030 – 1,04) mg/m3 Range (0,00030 – 0,75) mg in the sample
Microwave plasma atomic emission spectrometry (MP-AES) PB-06/08 issue 3 of 06.01.2025
32 Workplace environment – air – air samples Concentration/ content of mercury vapour and its inorganic compounds - calculated as Hg
Range (0,0017 – 1,03) mg/m3 Range (0,00060 – 0,37) mg in the sample
Microwave plasma atomic emission spectrometry (MP-AES) PB-06/08 issue 3 of 06.01.2025
33 Workplace environment – air – air samples Concentration/ content of barium and its soluble compounds - calculated as Ba
Range (0,017 – 1,50) mg/m3 Range (0,013 – 1,08) mg in the sample
Microwave plasma atomic emission spectrometry (MP-AES) PB-06/08 issue 3 of 06.01.2025
34 Workplace environment – air – air samples Concentration/ content of tungsten
inhalable fraction Concentration/ content of tungsten and its insoluble compounds - expressed as W Concentration/ content of tungsten and its soluble compounds - expressed as W Range (0,035 – 15,0) mg/m3 Range (0,025 – 10,8) mg in the sample
Microwave plasma atomic emission spectrometry (MP-AES) PB-06/08 issue 3 of 06.01.2025
35 Workplace environment – air – air samples Concentration/ content of lithium hydride
inhalable fraction Range (0,0008 – 0,20) mg/m3 Range (0,0006 – 0,144) mg in the sample
Microwave plasma atomic emission spectrometry (MP-AES) PB-06/08 issue 3 of 06.01.2025
36 Workplace environment – air – air samples Concentration/ content of zirconium and its compounds – calculated as Zr
Range (0,0694 – 20,0) mg/m3 Range (0,050 – 14,4) mg in the sample
Microwave plasma atomic emission spectrometry (MP-AES) PB-06/08 issue 3 of 06.01.2025
37 Workplace environment – air – air samples Concentration/ content of molybdenum and its compounds – calculated as Mo
Range (0,0694 – 20,0) mg/m3 Range (0,050 – 14,4) mg in the sample
Microwave plasma atomic emission spectrometry (MP-AES) PB-06/08 issue 3 of 06.01.2025
38 Workplace environment – air – air samples Concentration/ content of benzene
Range (0,0625 – 19,1) mg/m3 Range (0,0193 – 5,88) ppm Range (0,0018 – 0,80) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PB-06/09 issue 2 of 20.11.2023
39 Workplace environment – air – air samples Concentration/ content of toluene
Range (3,47 – 571) mg/m3 Range (0,100 – 10,0) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PB-06/09 issue 2 of 20.11.2023
40 Workplace environment – air – air samples Concentration/ content of n- butyl acetate
Range (1,39 – 1900) mg/m3 Range (0,040 – 11,2) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PB-06/09 issue 2 of 20.11.2023
41 Workplace environment – air – air samples Concentration/ content of ethyl acetate
Range (1,39 – 3000) mg/m3 Range (0,379 – 818,5) ppm Range (0,040 – 12,0) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PB-06/09 issue 2 of 20.11.2023
42 Workplace environment – air – air samples Concentration/ content of styrene
Range (3,47 – 1048) mg/m3 Range (0,100 – 15,0) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PB-06/09 issue 2 of 20.11.2023
43 Workplace environment – air – air samples Concentration/ content of xylene (mixture of isomers)
Range (1,39 – 250) mg/m3 Range (0,040 – 6,40) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PB-06/09 issue 2 of 20.11.2023
44 Workplace environment – air – air samples Concentration/ content of acetone
Range (1,04 – 3600) mg/m3 Range (0,030 – 14,00) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PB-06/09 issue 2 of 20.11.2023
45 Workplace environment – air – air samples Concentration/ content of butan-1-ol
Range (1,39 – 619) mg/m3 Range (0,040 – 12,0) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PB-06/09 issue 2 of 20.11.2023
46 Workplace environment – air – air samples Concentration/ content of cyclohexane
Range (2,78– 2000) mg/m3 Range (0,080– 15,0) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PB-06/09 issue 2 of 20.11.2023
47 Workplace environment – air – air samples Concentration/ content of butan-2-ol
Range (2,08 – 900) mg/m3 Range (0,060 –15,0) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PB-06/09 issue 2 of 20.11.2023
48 Workplace environment – air – air samples Concentration/ content of 2-butoxyethanol
Range (1,39 – 400) mg/m3 Range (0,040 – 8,00) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PB-06/09 issue 2 of 20.11.2023
49 Workplace environment – air – air samples Concentration/ content of 2-butoxyethyl acetate
Range (0,694 – 600) mg/m3 Range (0,020 – 12,6) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PB-06/09 issue 2 of 20.11.2023
50 Workplace environment – air – air samples Concentration/ content of butan-2-one
Range (1,74 – 1800) mg/m3 Range (0,050 – 9,50) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PB-06/09 issue 2 of 20.11.2023
51 Workplace environment – air – air samples Concentration/ content of ethylbenzene
Range (1,74 – 800) mg/m3 Range (0,050 – 15,0) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PB-06/09 issue 2 of 20.11.2023
52 Workplace environment – air – air samples Concentration/ content of ethyltoluene - mixture of isomers
Range (1,74 – 200) mg/m3 Range (0,050 – 8,40) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PB-06/09 issue 2 of 20.11.2023
53 Workplace environment – air – air samples Concentration/ content of 2-aminoethanol
Range (0,24 – 15,0) mg/m3 Range (0,0070 – 0,30) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PB-06/09 issue 2 of 20.11.2023
54 Workplace environment – air – air samples Concentration/ content of ethylene glycol
Range (1,39 – 60,0) mg/m3 Range (0,040 – 2,00) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PB-06/09 issue 2 of 20.11.2023
55 Workplace environment – air – air samples Concentration/ content of extraction naphtha
Range (1,74 – 3000) mg/m3 Range (0,050 – 18,0) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PB-06/09 issue 2 of 20.11.2023
56 Workplace environment – air – air samples Concentration/ content of white spirit
Range (5,21 – 1800) mg/m3 Range (0,150 – 18,0) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PB-06/09 issue 2 of 20.11.2023
57 Workplace environment – air – air samples Concentration/ content of hexane
Range (3,47 – 140) mg/m3 Range (0,100 – 5,80) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PB-06/09 issue 2 of 20.11.2023
58 Workplace environment – air – air samples Concentration/ content of propan-1-ol
Range (1,39 – 1200) mg/m3 Range (0,040 – 12,0) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PB-06/09 issue 2 of 20.11.2023
59 Workplace environment – air – air samples Concentration/ content of propan-2-ol
Range (1,39 – 2400) mg/m3 Range (0,040 – 11,50) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PB-06/09 issue 2 of 20.11.2023
60 Workplace environment – air – air samples Concentration/ content of 2–methoxy-1-methylethyl acetate
Range (5,21 – 1040) mg/m3 Range (0,150 – 22,0) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PB-06/09 issue 2 of 20.11.2023
61 Workplace environment – air – air samples Concentration/ content of 1-methoxy-2-propanol
Range (1,74 – 720) mg/m3 Range (0,050 – 15,0) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PB-06/09 issue 2 of 20.11.2023
62 Workplace environment – air – air samples Concentration/ content of trichloroethene
Range (1,04 – 200) mg/m3 Range (0,030 – 8,40) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PB-06/09 issue 2 of 20.11.2023
63 Workplace environment – air – air samples Concentration/ content of trimethylbenzene mixture of isomers (1,2,3 -,1,2,4 - and 1,3,5-)
Range (2,08 – 340) mg/m3 Range (0,060 – 8,40) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PB-06/09 issue 2 of 20.11.2023
64 Workplace environment – air – air samples Concentration/ content of trichlorobenzene mixture of isomers (1,2,3-, 1,2,4- and 1,3,5-)
Range (1,04 – 200) mg/m3 Range (0,030 – 8,40) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PB-06/09 issue 2 of 20.11.2023
65 Workplace environment – air – air samples Concentration/ content of tetrachloroethene
Range (1,39 – 340) mg/m3 Range (0,202 – 49,3) ppm Range (0,040 – 8,40) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PB-06/09 issue 2 of 20.11.2023
66 Workplace environment – air – air samples Concentration/ content of 2-methylpropan-1-ol
Range (1,04 – 400) mg/m3 Range (0,030 – 8,40) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PB-06/09 issue 2 of 20.11.2023
67 Workplace environment – air – air samples Concentration/ content of cyclohexanone
Range (0,69 – 160) mg/m3 Range (0,020 – 7,00) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PB-06/09 issue 2 of 20.11.2023
68 Workplace environment – air – air samples Concentration/ content of acetic acid
Range (1,23 – 100) mg/m3 Range (0,492 – 40,03) ppm Range (0,060 – 2,52) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PB-06/09 issue 2 of 20.11.2023
69 Workplace environment – air – air samples Concentration/ content of vinyl acetate
Range (1,04 – 60,0) mg/m3 Range (0,030 – 2,50) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PB-06/09 issue 2 of 20.11.2023
70 Workplace environment – air – air samples Concentration/ content of chloroform
Range (0,69 – 50,0) mg/m3 Range (0,020 – 4,00) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PB-06/09 issue 2 of 20.11.2023
71 Workplace environment – air – air samples Concentration/ content of kerosene
Range (1,74 –600) mg/m3 Range (0,050 – 9,50) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PB-06/09 issue 2 of 20.11.2023
72 Workplace environment – air – air samples Concentration/ content of 4-methylpentan-2-one
Range (1,39 – 400) mg/m3 Range (0,040 – 17,0) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PB-06/09 issue 2 of 20.11.2023
73 Workplace environment – air – air samples Concentration/ content of methanol
Range (5,56 – 600) mg/m3 Range (0,040 – 5,50) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PB-06/09 issue 2 of 20.11.2023
74 Workplace environment – air – air samples Concentration/ content of ethanol
Range (27,50 – 3900) mg/m3 Range (0,055 – 5,00) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PB-06/09 issue 2 of 20.11.2023
75 Workplace environment – air – air samples Concentration/ content of 1-methyl-2-pyrrolidone
Range (2,78 – 200) mg/m3 Range (0,674 – 48,5) ppm Range (0,050 – 5,00) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PB-06/09 issue 2 of 20.11.2023
76 Workplace environment – air – air samples Concentration/ content of 4-hydroxy-4-methylpentan-2-one
Range (5,55 – 600) mg/m3 Range (0,100 – 12,0) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PB-06/09 issue 2 of 20.11.2023
77 Workplace environment – air – air samples Concentration/ content of 2-(2-butoxyethoxy) ethanol
Range (2,78 – 200) mg/m3 Range (0,050 – 6,00) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PB-06/09 issue 2 of 20.11.2023
78 Workplace environment – air – air samples Concentration/ content of heptane
Range (1,74 –4000) mg/m3 Range (0,050 – 18,0) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PB-06/09 issue 2 of 20.11.2023
79 Workplace environment – air – air samples Concentration/ content of chlorobenzene
Range (1,74 – 200) mg/m3 Range (0,050 – 3,00) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PB-06/09 issue 2 of 20.11.2023
80 Workplace environment – air – air samples Concentration/ content of highly refined mineral oil excluding metalworking fluids
inhalable fraction Range (0,42 – 20,8) mg/m3 Range (0,30 – 7,2) mg in the sample
Ultraviolet absorption spectrometry method PN-Z-04108-6:2006 + Az1:2009
81 Workplace environment – air – air samples Ammonia concentration
Range (1,30 – 40,0) mg/m3
Spectrophotometric method PN-71/Z-04041
82 Workplace environment – air – air samples Sulfur trioxide concentration
Range (0,092 – 7,0) mg/m3
Turbidimetric method PN-91/Z-04056/02
83 Workplace environment – air – air samples Chlorine concentration
Range (0,0625 – 3,00) mg/m3
Spectrophotometric method PN-75/Z-04037/03 excluding cl. 5d
84 Workplace environment – air – air samples Ozone concentration
Range (0,0125 – 0,25) mg/m3
Spectrophotometric method PN-94/Z-04007-2
85 Workplace environment – air – air samples Sodium cyanide concentration, calculated as CN
Range (0,069 – 10) mg/m3
Spectrophotometric method PN-Z-04309: 2002
86 Workplace environment – air – air samples Hydrogen sulphide concentration
Range (0,70 – 40) mg/m3
Spectrophotometric method PN-Z-04015-13:1996 excluding cl. 5c, 5d, 5h
87 Workplace environment – air – air samples Hydrogen peroxide concentration
Range (0,040 – 1,6) mg/m3
Spectrophotometric method PN-Z-04548:2023-03
88 Workplace environment – air – air samples Concentration / content of chromium (VI) compounds calculated as Cr (VI)
Range (0,000417– 0,6) mg/m3 Range (0,0003 – 0,432) mg in the sample
Spectrophotometric method PN-87/Z-04126/02
89 Workplace environment – air – air samples Ammonium chloride concentration – vapours and inhalable fraction
Range (0,01 – 40,0) mg/m3
Spectrophotometric method PN-Z-04265:2000
90 Workplace environment – air – air samples Carbon monoxide concentration
Range (2,32 – 232) mg/m3 Range (2,0 – 200,0) ppm
Electrochemical method PB-06/10 issue 1 of 02.01.2020
91 Workplace environment – air – air samples Nitrogen oxide concentration
Range (0,62 – 25) mg/m3 Range (0,50 – 20,0) ppm
Electrochemical method PB-06/10 issue 1 of 02.01.2020
92 Workplace environment – air – air samples Nitrogen dioxide concentration
Range (0,11 – 29) mg/m3 Range (0,06 – 15,00) ppm
Electrochemical method PB-06/10 issue 1 of 02.01.2020
93 Workplace environment – air – air samples Exposure index (calculated) PB-06/10 issue 1 of 02.01.2020
94 Workplace environment – air – air samples Fluoride concentration calculated as F
Range (0,014 – 5,0) mg/m3
Ion chromatography with conductometric detection (IC-CD) NIOSH 7906 Method, Issue 2, 20 May 2014
95 Workplace environment – air – air samples Hydrogen fluoride concentration
Range (0,015 – 20,0) mg/m3
Ion chromatography with conductometric detection (IC-CD) NIOSH 7906 Method, Issue 2, 20 May 2014
96 Workplace environment – air – air samples Hydrogen chloride concentration
Range (0,16 – 20,0) mg/m3
Ion chromatography with conductometric detection (IC-CD) NIOSH 7907 Method, Issue 1, 20 May 2014
97 Workplace environment – air – air samples Nitric acid concentration
Range (0,10 – 5,60) mg/m3
Ion chromatography with conductometric detection (IC-CD) NIOSH 7907 Method, Issue 1, 20 May 2014
98 Workplace environment – air – air samples Concentration / content of sulphuric acid
thoracic fraction Range (0,0046 – 0,15) mg/m3 Range (0,0033 – 0,050) mg in the sample
Ion chromatography with conductometric detection (IC-CD) Principles and Methods of Assessing the Working Environment 2012, No. 1 (71), pp. 97–103 Principles and Methods of Assessing the Working Environment 2017, No. 2 (92), pp. 5–19
99 Workplace environment – air – air samples Nitrogen oxide concentration / content
Range (0,03 – 5,0) mg/m3 Range (0,024 – 4,01) ppm Range (0,00030 – 0,050) mg in the sample
Ion chromatography with conductometric detection (IC-CD) OSHA Method190
100 Workplace environment – air – air samples Nitrogen dioxide concentration / content
Range (0,046 – 5) mg/m3 Range (0,024 – 2,61) ppm Range (0,00046 – 0,050) mg in the sample
Ion chromatography with conductometric detection (IC-CD) OSHA Method182
101 Workplace environment – air – air samples Concentration / content of phosphoric acid
Range (0,0014 – 5,37) mg/m3 Range (0,0010 – 3,87) mg in the sample
Ion chromatography with conductometric detection (IC-CD) NIOSH 7908 Method Issue 2, 16 November 2023
102 Workplace environment – air – air samples Concentration / content of sulphur dioxide
Range (0,110 – 4,40) mg/m3 Range (0,041 – 1,66) ppm Range (0,020 – 0,792) mg in the sample
Ion chromatography with conductometric detection (IC-CD) Principles and Methods of Assessing the Working Environment 2025, No. 4 (126), pp. 133–146
103 Workplace environment – air – air samples Formaldehyde concentration / content
Range (0,0057 – 20) mg/m3 Range (0,0016 – 0,072) mg in the sample
High-performance liquid chromatography with spectrophotometric detection (HPLC-UV) NIOSH 2016, Issue 2:15 March 2003 | PB-06/17 issue 1 of 06.03.2025
104 Workplace environment – air – air samples collected on impregnated filters Concentration / content of: toluene-2,4-diyl diisocyanate, toluene 2,6-diyl diisocyanate, toluenediyl diisocyanate – mixture of isomers 2,4-, 2,6- expressed as NCO group
Range (0,0000676 – 0,24) mg/m3 Range (0,0135– 7,24) μg in the sample Diisocyanates – expressed as NCO group (sum of concentrations/contents of isocyanate functional groups of diisocyanate compounds)
High-performance liquid chromatography with fluorescence detection (HPLC-FLD) PN-Z-04490:2017-10
105 Workplace environment – air – air samples collected on impregnated filters Concentration / content of: hexane-1,6-diyl diisocyanate expressed as NCO group
Range (0,0002248 – 0,25) mg/m3 Range (0,0450 – 7,49) μg in the sample Diisocyanates – expressed as NCO group (sum of concentrations/contents of isocyanate functional groups of diisocyanate compounds)
High-performance liquid chromatography with fluorescence detection (HPLC-FLD) OSHA Method 5002
106 Workplace environment – air – air samples collected on impregnated filters Concentration / content of: 4,4’ methylenebis(phenyl isocyanate) expressed as NCO group
: (0,000151 – 0,17) mg/m3 : (0,0302 – 5,037) μg in the sample Diisocyanates – expressed as NCO group (sum of concentrations/contents of isocyanate functional groups of diisocyanate compounds)
High-performance liquid chromatography with fluorescence detection (HPLC-FLD) OSHA Method 5002
107 Workplace environment – noise A-weighted equivalent sound level Maximum A-weighted sound level
Range (25 - 135) dB C-weighted peak sound pressure level Range (35 - 140) dB
Direct measurement method PN-N-01307:1994 | PN-EN ISO 9612:2025-11 excluding the method covering strategies 2 and 3 - cl. 10 and 11
108 Workplace environment – noise Noise exposure level referred to:
8-hour daily working time the average weekly working time (calculated)
PN-N-01307:1994 | PN-EN ISO 9612:2025-11 excluding the method covering strategies 2 and 3 - cl. 10 and 11
109 Workplace environment – noise Equivalent sound pressure level in octave bands with centre frequencies from 16 Hz to 16000 Hz
Range (35 - 140) dB
PB-06/03 edition 1 of 02.01.2020
110 Workplace environment – ultrasonic noise Equivalent sound pressure levels in one-third octave bands with centre frequencies from 10 kHz to 40 kHz Maximum sound pressure levels in one-third octave bands with centre frequencies from 10 kHz to 40 kHz
Range (60 - 140) dB
Direct measurement method PN-Z-01339:2020-12
111 Workplace environment – ultrasonic noise Equivalent sound pressure levels in third-octave bands with centre frequencies from 10 kHz to 40 kHz referred to:
an 8-hour daily working time the average weekly working time (calculated)
PN-Z-01339:2020-12
112 Workplace environment – hand-arm vibration transmitted to the human body Frequency-weighted r.m.s. vibration acceleration
Range (0,1 – 100) m/s2
Direct measurement method PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004+A1:2015-11
113 Workplace environment – hand-arm vibration transmitted to the human body Daily exposure, expressed as the energy-equivalent value for an 8-hour working day of the vector sum of the frequency-corrected r.m.s. vibration accelerations, determined for the three directional components (ahwx, ahwy, ahwz), Exposure lasting 30 minutes or less, expressed as the vector sum of the frequency-weighted r.m.s. vibration accelerations, determined for the three directional components (ahwx, ahwy, ahwz) (calculated) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004+A1:2015-11
114 Workplace environment – whole-body vibration Frequency-weighted r.m.s. vibration acceleration
Range (0,01 – 50) m/s2
Direct measurement method PN-EN 14253+A1:2011
115 Workplace environment – whole-body vibration Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the r.m.s. frequency-corrected vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz), Exposure lasting 30 minutes or less, expressed as the r.m.s. frequency-weighted vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz) (calculated) PN-EN 14253+A1:2011
116 Workplace environment – moderate microclimate Air temperature
Range (5 – 50) °C Black globe temperature Range (5 – 60) °C Air humidity Range (20,0 – 90) % Air velocity Range (0,15 – 5,0) m/s
Direct measurement method PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04
117 Workplace environment – moderate microclimate PMV index, PPD index (calculated) PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04
118 Workplace environment – hot microclimate Air temperature
Range (10 – 50) °C Natural wet bulb temperature Range (5 – 45) °C Black globe temperature Range (10 – 60) °C Air velocity Range (0,15 – 5,0) m/s
Direct measurement method PN-EN ISO 7243:2018-01 | PN-EN ISO 7243:2018-01/Ap2:2020-04
119 Workplace environment – hot microclimate WBGT index, WBGTeff index (calculated) PN-EN ISO 7243:2018-01 | PN-EN ISO 7243:2018-01/Ap2:2020-04
120 Workplace environment – cold microclimate Air temperature
Range (-20 – 10) °C Black globe temperature Range (-20 – 10) °C Air humidity Range (20 – 90) % Air velocity Range (0,15 – 5,0) m/s
Direct measurement method PN-EN ISO11079:2008+Ap1:2013-10
121 Workplace environment – cold microclimate IREQmin index, IREQneutral index, twc index (calculated) PN-EN ISO11079:2008+Ap1:2013-10
122 Workplace environment – electric lighting Illuminance
Range (5 – 5000) lx
Direct measurement method PB-06/01 issue 2 of 01.02.2024
123 Workplace environment – electric lighting Illuminance uniformity (calculated) PB-06/01 issue 2 of 01.02.2024
124 Workplace environment – electric lighting Luminance
Range (25 – 400) cd/m2
PB-06/01 issue 2 of 01.02.2024
125 Workplace environment – electric lighting Reflection coefficients on the main interior surfaces (calculated) PB-06/01 issue 2 of 01.02.2024
126 Workplace environment – non-laser optical radiation Effective irradiance of UVA, UVB and UVC in the spectral range (180 – 400) nm
Range (3,0*10 -6 – 25,0) W/m2
Direct measurement method (method A) PN-EN 14255-1:2010
127 Workplace environment – non-laser optical radiation Effective radiant exposure to hazardous ultraviolet in the spectral range (180 – 400) nm (calculated) PN-EN 14255-1:2010
128 Workplace environment – non-laser optical radiation Irradiance of UVA radiation in the spectral range (315 – 400) nm
Range (2,00-6 – 1000) W/m2
Direct measurement method (method M) PN-EN 14255-1:2010
129 Workplace environment – non-laser optical radiation Radiant exposure to UVA radiation in the spectral range (315 – 400) nm (calculated) PN-EN 14255-1:2010
130 Workplace environment – non-laser optical radiation Effective irradiance VIS in the spectral range (305 – 700) nm
Range (7,69*10-7– 1540) W/m2
Direct measurement method (method O) PN-EN 14255-2:2010
131 Workplace environment – non-laser optical radiation Effective radiance of VIS radiation in the spectral range (305 – 700) nm (calculated) PN-EN 14255-2:2010
132 Workplace environment – non-laser optical radiation Irradiance of IRA and IRB in the spectral range (780 – 3000) nm
Range (0,9 – 4000) W/m2
Direct measurement method (method R) PN-EN 14255-2:2010
133 Workplace environment – non-laser optical radiation Radiant exposure in the spectral range (780 – 3000) nm (calculated) PN-EN 14255-2:2010
134 Workplace environment – non-laser optical radiation Effective irradiance of IRA in the spectral range (780 – 1400) nm
Range (4,0*10-7 – 300) W/m2
Direct measurement method PN-T-05687:2002 cl. 2.5.4 and cl. 2.5.5
135 Workplace environment – non-laser optical radiation Effective radiance IRA in the spectral range (770 –1400) nm (calculated) PN-T-05687:2002 cl. 2.5.4 and cl. 2.5.5
136 General environment – noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level
Range (25 – 110) dB A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated)
Direct measurement method Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023 item 1706)
137 General environment – noise from installations, equipment and industrial plants Equivalent A-weighted sound level for the reference time T expressed by the indicators LAeqD and LAeqN Calculation method PN ISO 9613-2:2002
138 Machinery and equipment - noise Sound pressure level
weighted with the characteristic frequency weighting A Range (25 – 110) dB
Direct measurement method PN-EN ISO 3746:2011 | PN-EN ISO 3746:2011/Ap1:2017-09
139 Machinery and equipment - noise Sound power level (calculated) PN-EN ISO 3746:2011 | PN-EN ISO 3746:2011/Ap1:2017-09

Reference standards (49)

NIOSH 2016, Issue 2:15 March 2003
NIOSH 7906 Method, Issue 2, 20 May 2014
NIOSH 7907 Method, Issue 1, 20 May 2014
NIOSH 7908 Method Issue 2, 16 November 2023
OSHA Method 5002
OSHA Method182
OSHA Method190
PB-06/01 issue 2 of 01.02.2024
PB-06/03 edition 1 of 02.01.2020
PB-06/08 issue 3 of 06.01.2025
PB-06/09 issue 2 of 20.11.2023
PB-06/10 issue 1 of 02.01.2020
PB-06/17 issue 1 of 06.03.2025
PB-06/32 issue 1 of 20.11.2023
PN ISO 9613-2:2002
PN-71/Z-04041
PN-75/Z-04037/03 excluding cl. 5d
PN-87/Z-04126/02
PN-91/Z-04056/02
PN-94/Z-04007-2
PN-EN 14253+A1:2011
PN-EN 14255-1:2010
PN-EN 14255-2:2010
PN-EN ISO 3746:2011
PN-EN ISO 3746:2011/Ap1:2017-09
PN-EN ISO 5349-1:2004
PN-EN ISO 5349-2:2004+A1:2015-11
PN-EN ISO 7243:2018-01
PN-EN ISO 7243:2018-01/Ap2:2020-04
PN-EN ISO 7730:2006
PN-EN ISO 7730:2006/Ap2:2016-04
PN-EN ISO 9612:2025-11 excluding the method covering strategies 2 and 3 - cl. 10 and 11
PN-EN ISO11079:2008+Ap1:2013-10
PN-N-01307:1994
PN-T-05687:2002 cl. 2.5.4 and cl. 2.5.5
PN-Z-01339:2020-12
PN-Z-04008-7:2002 + Az1:2004
PN-Z-04015-13:1996 excluding cl. 5c, 5d, 5h
PN-Z-04108-6:2006 + Az1:2009
PN-Z-04265:2000
PN-Z-04309: 2002
PN-Z-04490:2017-10
PN-Z-04507:2022-05
PN-Z-04508:2022-05
PN-Z-04548:2023-03
Principles and Methods of Assessing the Working Environment 2012, No. 1 (71), pp. 97–103 Principles and Methods of Assessing the Working Environment 2017, No. 2 (92), pp. 5–19
Principles and Methods of Assessing the Working Environment 2012, No. 4 (74), pp. 117–130
Principles and Methods of Assessing the Working Environment 2025, No. 4 (126), pp. 133–146
Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023 item 1706)

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/PL/AB%20802