🇵🇱 ZEC DIAGPOM Sp z o. o. PL

PCA AB 782 • Wrocław, Poland • 163 methods

EnvironmentWater & wastewater

ZEC DIAGPOM Sp z o. o. is a laboratory accredited by PCA under number AB 782 (Wrocław, Poland). Its accreditation scope covers 163 test methods in the following areas: Environment, Water & wastewater. Test objects include: Waste gases, Automated Measuring Systems (AMS), Water, Wastewater, Workplace environment − air. Most frequently used techniques: Spectrophotometric method, Gravimetric method, Direct measurement method.

At a glance

  • Accreditation number: PCA AB 782
  • Methods in scope: 163
  • Types of test objects: 18
  • Techniques used: 33
  • City: Wrocław, Poland
Accreditation number
AB 782
Accreditation body
PCA
Address
LABORATORIUM BADAŃ ŚRODOWISKOWYCH, ul. Łowiecka 24, 50-220 Wrocław
City
Wrocław, Poland

What this laboratory tests (18)

Analytical techniques used (33)

Laboratory locations

Certificate information

Issue date
12.10.2026
Issue no.
25

Accreditation scope — test methods (163)

No. Test object Methodology / Parameters Technique Reference document
Environmental Testing Laboratory
1 Waste gases Gas volume flow rate for dynamic pressures > 5 Pa
Velocity Range (1,00 – 8,00) m/s
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. The laboratory formulates opinions and interpretations in test reports for the tests marked with the symbol ←
Stagnation pressure method; Anemometric method PN-Z-04030-7:1994 ←
2 Waste gases Sampling for determination of dust concentration
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. The laboratory formulates opinions and interpretations in test reports for the tests marked with the symbol ←
PN-Z-04030-7:1994 ←
3 Waste gases Dust concentration
Range (0,001 – 100) g/m3
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. The laboratory formulates opinions and interpretations in test reports for the tests marked with the symbol ←
Gravimetric method PN-Z-04030-7:1994 ←
4 Waste gases Dust emission (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. The laboratory formulates opinions and interpretations in test reports for the tests marked with the symbol ←
PN-Z-04030-7:1994 ←
5 Waste gases Sampling for determination of the dust fraction
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. The laboratory formulates opinions and interpretations in test reports for the tests marked with the symbol ←
PN-Z-04030-7:1994 ←
6 Waste gases Emission of the dust fraction (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. The laboratory formulates opinions and interpretations in test reports for the tests marked with the symbol ←
PN-Z-04030-7:1994 ←
7 Waste gases Gas volume flow rate for dynamic pressures > 5 Pa
Velocity Range (1,00 – 8,00) m/s
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Differential pressure measurement method; Anemometric method PN-EN ISO 16911-1:2013 | CEN/TR 17078:2017-03
8 Waste gases Sampling for determination of dust concentration
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. The laboratory formulates opinions and interpretations in test reports for the tests marked with the symbol ←
PN-EN 13284-1:2018-02 ←
9 Waste gases Dust concentration
Range (0,0002– 0,05) g/m3
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. The laboratory formulates opinions and interpretations in test reports for the tests marked with the symbol ←
Gravimetric method PN-EN 13284-1:2018-02 ←
10 Waste gases Dust emission (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. The laboratory formulates opinions and interpretations in test reports for the tests marked with the symbol ←
PN-EN 13284-1:2018-02 ←
11 Waste gases Sampling for determination of the dust fraction
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. The laboratory formulates opinions and interpretations in test reports for the tests marked with the symbol ←
PN-EN 13284-1:2018-02 ←
12 Waste gases Emission of the dust fraction (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. The laboratory formulates opinions and interpretations in test reports for the tests marked with the symbol ←
PN-EN 13284-1:2018-02 ←
13 Waste gases Nitrogen oxides concentration
NO (0,7 – 1340) mg/m3 NO2 (1,1 – 2050) mg/m3 NOx (1,1 – 2050) mg/m3
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. The laboratory formulates opinions and interpretations in test reports for the tests marked with the symbol ←
Chemiluminescence method PN-EN 14792:2017-04 ←
14 Waste gases NOx emission (calculated as NO2) (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. The laboratory formulates opinions and interpretations in test reports for the tests marked with the symbol ←
PN-EN 14792:2017-04 ←
15 Waste gases Sulphur dioxide concentration
SO2 (1,5 – 8580) mg/m3
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. The laboratory formulates opinions and interpretations in test reports for the tests marked with the symbol ←
Non-dispersive infrared spectrometry (NDIR) PN-ISO 10396:2001 ← | PN-ISO 7935:2000
16 Waste gases SO2 emission (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. The laboratory formulates opinions and interpretations in test reports for the tests marked with the symbol ←
PN-ISO 10396:2001 ← | PN-ISO 7935:2000
17 Waste gases Carbon dioxide concentration
Range (0,1 – 30) %
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. The laboratory formulates opinions and interpretations in test reports for the tests marked with the symbol ←
Non-dispersive infrared spectrometry (NDIR) ISO 12039:2019 ← | PN-ISO 10396:2001
18 Waste gases CO2 emission (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. The laboratory formulates opinions and interpretations in test reports for the tests marked with the symbol ←
ISO 12039:2019 ← | PN-ISO 10396:2001
19 Waste gases Carbon monoxide concentration
Range (0,8 – 6250) mg/m3
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. The laboratory formulates opinions and interpretations in test reports for the tests marked with the symbol ←
Non-dispersive infrared spectrometry (NDIR) PN-EN 15058:2017-04 ←
20 Waste gases CO emission (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. The laboratory formulates opinions and interpretations in test reports for the tests marked with the symbol ←
PN-EN 15058:2017-04 ←
21 Waste gases Oxygen concentration
Range (0,1 – 25) %
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. The laboratory formulates opinions and interpretations in test reports for the tests marked with the symbol ←
Paramagnetic method PN-EN 14789:2017-04 ←
22 Waste gases Sampling for the determination of sulfur dioxide concentration
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. The laboratory formulates opinions and interpretations in test reports for the tests marked with the symbol ←
PN-EN 14791:2017-04 ←
23 Waste gases Concentration / content of sulphur dioxide
Range (1 – 15000) mg/m3 Range (0,72 – 450) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. The laboratory formulates opinions and interpretations in test reports for the tests marked with the symbol ←
Thoron method PN-EN 14791:2017-04 ←
24 Waste gases SO2 emission (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. The laboratory formulates opinions and interpretations in test reports for the tests marked with the symbol ←
PN-EN 14791:2017-04 ←
25 Waste gases Sampling for determination of hydrogen chloride concentration
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. The laboratory formulates opinions and interpretations in test reports for the tests marked with the symbol ←
PN-EN 1911:2011 ←
26 Waste gases Hydrogen chloride concentration / content
Range (0,1 – 5000) mg/m3 Range (0,06 – 300) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. The laboratory formulates opinions and interpretations in test reports for the tests marked with the symbol ←
Spectrophotometric method PN-EN 1911:2011 ←
27 Waste gases HCl emission (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. The laboratory formulates opinions and interpretations in test reports for the tests marked with the symbol ←
PN-EN 1911:2011 ←
28 Waste gases Sampling for determination of hydrogen fluoride concentration
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. The laboratory formulates opinions and interpretations in test reports for the tests marked with the symbol ←
ISO 15713:2006 ←
29 Waste gases Concentration / content of hydrogen fluoride
Range (0,1 − 200) mg/m3 Range (0,01 – 20) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. The laboratory formulates opinions and interpretations in test reports for the tests marked with the symbol ←
Method using an ion-selective electrode ISO 15713:2006 ←
30 Waste gases HF emission (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. The laboratory formulates opinions and interpretations in test reports for the tests marked with the symbol ←
ISO 15713:2006 ←
31 Waste gases Sampling for the determination of metal concentrations (As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. The laboratory formulates opinions and interpretations in test reports for the tests marked with the symbol ←
PN-EN 14385:2025-05 ←
32 Waste gases Emission of As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. The laboratory formulates opinions and interpretations in test reports for the tests marked with the symbol ←
PN-EN 14385:2025-05 ←
33 Waste gases Sampling for determination of the mass concentration of PCDD/PCDF
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Filtration-condensation method PN-EN 1948-1:2006
34 Waste gases PCDD/PCDF emission (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
PN-EN 1948-1:2006
35 Waste gases Sampling for determination of total mercury concentration
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. The laboratory formulates opinions and interpretations in test reports for the tests marked with the symbol ←
PN-EN 13211+AC:2006 ←
36 Waste gases Total mercury concentration
Range (0,0033 – 770) μg/m3 Range (0,007 – 87,5) μg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. The laboratory formulates opinions and interpretations in test reports for the tests marked with the symbol ←
Cold vapour atomic absorption spectrometry (CVAAS) PN-EN 13211+AC:2006 ←
37 Waste gases Total mercury emission (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. The laboratory formulates opinions and interpretations in test reports for the tests marked with the symbol ←
PN-EN 13211+AC:2006 ←
38 Waste gases Sampling for determination of the concentration of individual gaseous organic compounds
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. The laboratory formulates opinions and interpretations in test reports for the tests marked with the symbol ←
Aspiration method using activated carbon PN-EN 13649:2005 ←
39 Waste gases Emission of individual gaseous organic compounds (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. The laboratory formulates opinions and interpretations in test reports for the tests marked with the symbol ←
PN-EN 13649:2005 ←
40 Waste gases Water vapour concentration (H20)
Range (23 – 250) g/m3 Range (3 – 40) % Range (3,14 – 57)%
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. The laboratory formulates opinions and interpretations in test reports for the tests marked with the symbol ←
Condensation-adsorption method; Temperature method PN-EN 14790:2017-04 ←
41 Waste gases Concentration of organic substances in the form of gases and vapours expressed as total gaseous organic carbon
Range (0,5 – 1000) mg/m3
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. The laboratory formulates opinions and interpretations in test reports for the tests marked with the symbol ←
Continuous measurement with flame ionization detection (FID) PN-EN 12619:2013-05 ←
42 Waste gases Emission of organic substances in gaseous and vapour form expressed as total gaseous organic carbon (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. The laboratory formulates opinions and interpretations in test reports for the tests marked with the symbol ←
PN-EN 12619:2013-05 ←
43 Waste gases Sampling for determination of the concentration of sulfuric acid including sulfur trioxide
Regulated area: The laboratory formulates opinions and interpretations in test reports for the tests marked with the symbol ←
Aspiration method using absorbing solutions LBŚ-PB-24 issue 3 of 17.10.2022 ←
44 Waste gases Concentration / content of sulphuric acid
Range (0,38 – 7650) mg/m3 Range (0,102 – 459) mg in the sample
Regulated area: The laboratory formulates opinions and interpretations in test reports for the tests marked with the symbol ←
Thoron method LBŚ-PB-24 issue 3 of 17.10.2022 ←
45 Waste gases Emission of H2SO4 (calculated)
Regulated area: The laboratory formulates opinions and interpretations in test reports for the tests marked with the symbol ←
LBŚ-PB-24 issue 3 of 17.10.2022 ←
46 Waste gases Concentration / content of sulfur trioxide
Range (0,31 – 6250) mg/m3 Range (0,083 – 375) mg in the sample
Regulated area: The laboratory formulates opinions and interpretations in test reports for the tests marked with the symbol ←
Thoron method LBŚ-PB-24 issue 3 of 17.10.2022 ←
47 Waste gases SO3 emission (calculated)
Regulated area: The laboratory formulates opinions and interpretations in test reports for the tests marked with the symbol ←
LBŚ-PB-24 issue 3 of 17.10.2022 ←
48 Waste gases N2O concentration
Range (0,8 – 980) mg/m3
Regulated area: The laboratory formulates opinions and interpretations in test reports for the tests marked with the symbol ←
Non-dispersive infrared spectrometry (NDIR) PN-EN ISO 21258:2010 ←
49 Waste gases N2O emission (calculated)
Regulated area: The laboratory formulates opinions and interpretations in test reports for the tests marked with the symbol ←
PN-EN ISO 21258:2010 ←
50 Waste gases Ammonia concentration
NH3 (0,38 − 38) mg/m3
Regulated area: The laboratory formulates opinions and interpretations in test reports for the tests marked with the symbol ←
Fourier transform infrared spectroscopy (FTIR) LBŚ-PB-23 issue 4 of 13.07.2020 ← | ISO 17179:2016
51 Waste gases NH3 emission (calculated)
Regulated area: The laboratory formulates opinions and interpretations in test reports for the tests marked with the symbol ←
LBŚ-PB-23 issue 4 of 13.07.2020 ← | ISO 17179:2016
52 Waste gases Sampling for determination of ammonia PN-EN ISO 21877:2020-03
53 Waste gases Ammonia concentration / content
Range (0,06 – 629) mg/m3 Range (0,095 – 236) mg/l in the sample
Spectrophotometric method PN-EN ISO 21877:2020-03
54 Waste gases Ammonia emission (calculated) PN-EN ISO 21877:2020-03
55 Waste gases Methane concentration
CH4 (0,4 – 71,0) mg/m3
Regulated area: The laboratory formulates opinions and interpretations in test reports for the tests marked with the symbol ←
Fourier transform infrared spectroscopy method (FT-IR) LBŚ-PB-23 issue 4 of 13.07.2020 ←
56 Waste gases CH4 emission (calculated)
Regulated area: The laboratory formulates opinions and interpretations in test reports for the tests marked with the symbol ←
LBŚ-PB-23 issue 4 of 13.07.2020 ←
57 Waste gases Sampling for the determination of PAH concentration
Regulated area: The laboratory formulates opinions and interpretations in test reports for the tests marked with the symbol ←
Condensation-adsorption method with a heated filter ISO 11338-1:2003 – Method B ←
58 Waste gases PAH emission (calculated)
Regulated area: The laboratory formulates opinions and interpretations in test reports for the tests marked with the symbol ←
ISO 11338-1:2003 – Method B ←
59 Waste gases Sampling for determination of the concentration of oxidised, elemental and particulate mercury LBŚ-PB-22 issue 4 of 30.11.2016
60 Waste gases Emission of Hg22+, Hg2+, Hg0, Hgdust (calculated) LBŚ-PB-22 issue 4 of 30.11.2016
61 Waste gases Sampling for determination of metal concentrations (As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V, Be, Sn, Zn, Se, Te)
Regulated area: The laboratory formulates opinions and interpretations in test reports for the tests marked with the symbol ←
PN-EN 14385:2025 -05 ←
62 Waste gases Emission of As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V, Be, Sn, Zn, Se, Te (calculated)
Regulated area: The laboratory formulates opinions and interpretations in test reports for the tests marked with the symbol ←
PN-EN 14385:2025 -05 ←
63 Waste gases Sampling for determination of the mass concentration of dioxin-like PCBs PN-EN 1948-4+A1:2014-03
64 Waste gases PCB emission (calculated) PN-EN 1948-4+A1:2014-03
65 Waste gases Sampling for the determination of formaldehyde CEN/TS 17638:2021
66 Waste gases Formaldehyde concentration / content
Range (0,035 – 700) mg/m3 Range (0,0042 – 42) mg in the sample
Spectrophotometric method CEN/TS 17638:2021
67 Waste gases Emission of CH2O (calculated) CEN/TS 17638:2021
68 Waste gases Sampling for the determination of hydrogen sulphide LBŚ-PB-25 issue 1 of 15.03.2024
69 Waste gases Hydrogen sulphide concentration / content
Range (0,055 – 373) mg/m3 Range (0,01 – 11,2) mg in the sample
Spectrophotometric method LBŚ-PB-25 issue 1 of 15.03.2024
70 Waste gases H2S emission (calculated) LBŚ-PB-25 issue 1 of 15.03.2024
71 Waste gases Sampling for the determination of brominated flame retardants PN-EN 1948-1:2006 | LBŚ-IR-36 issue 6 of 11.03.2024
72 Waste gases Emission of brominated flame retardants (calculated) PN-EN 1948-1:2006 | LBŚ-IR-36 issue 6 of 11.03.2024
73 Waste gases Sampling for determination of methane concentration (CH4)
Regulated area: The laboratory formulates opinions and interpretations in test reports for the tests marked with the symbol ←
PN-EN ISO 25139:2011 ←
74 Waste gases Emission of methane (CH4) (calculated)
Regulated area: The laboratory formulates opinions and interpretations in test reports for the tests marked with the symbol ←
PN-EN ISO 25139:2011 ←
75 Waste gases Dust sampling for the determination of PM 2,5 and PM 10 dust concentration
Regulated area: The laboratory formulates opinions and interpretations in test reports for the tests marked with the symbol ←
PN-EN ISO 23210:2010 ←
76 Waste gases PM 2,5 dust concentration
Range (0,0002 – 0,04) g/m3 PM 10 dust concentration Range (0,0003 – 0,04) g/m3
Regulated area: The laboratory formulates opinions and interpretations in test reports for the tests marked with the symbol ←
Gravimetric method (impactor) PN-EN ISO 23210:2010 ←
77 Waste gases PM 2,5 and PM 10 dust emission (calculated)
Regulated area: The laboratory formulates opinions and interpretations in test reports for the tests marked with the symbol ←
PN-EN ISO 23210:2010 ←
78 Automated Measuring Systems (AMS) AMS calibration (QAL2) for:
dust, SO2, NO, NO2, NOx, CO O2, CO2, N2O, H2O, HF, HCl, Hg, TVOC
Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. The laboratory formulates opinions and interpretations in test reports for the tests marked with the symbol ←
PN-EN 14181:2015 ←
79 Automated Measuring Systems (AMS) Annual surveillance test (AST) for:
dust, SO2, NO, NO2, NOx, CO O2, CO2, N2O, H2O, HF, HCl, Hg, TVOC
Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. The laboratory formulates opinions and interpretations in test reports for the tests marked with the symbol ←
PN-EN 14181:2015 ←
80 Automated Measuring Systems (AMS) Dust concentration
Range (0,001 – 100) g/m3
Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. The laboratory formulates opinions and interpretations in test reports for the tests marked with the symbol ←
Gravimetric method PN-Z-04030-7:1994 ←
81 Automated Measuring Systems (AMS) Dust concentration
Range (0,0002 – 0,05) g/m3
Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. The laboratory formulates opinions and interpretations in test reports for the tests marked with the symbol ←
Gravimetric method PN-EN 13284-1:2018-02 ←
82 Automated Measuring Systems (AMS) SO2 concentration
Range (1 – 15000) mg/m3
Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. The laboratory formulates opinions and interpretations in test reports for the tests marked with the symbol ←
Thoron method PN-EN 14791:2017-04 ←
83 Automated Measuring Systems (AMS) NO concentration
Range (0,7 – 1340) mg/m3
Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. The laboratory formulates opinions and interpretations in test reports for the tests marked with the symbol ←
Chemiluminescence method PN-EN 14792:2017-04 ←
84 Automated Measuring Systems (AMS) NO2 concentration
Range (1,1 – 2050) mg/m3
Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. The laboratory formulates opinions and interpretations in test reports for the tests marked with the symbol ←
Chemiluminescence method PN-EN 14792:2017-04 ←
85 Automated Measuring Systems (AMS) NOx concentration
Range (1,1 – 2050) mg/m3
Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. The laboratory formulates opinions and interpretations in test reports for the tests marked with the symbol ←
Chemiluminescence method PN-EN 14792:2017-04 ←
86 Automated Measuring Systems (AMS) CO concentration
Range (0,8 - 6250) mg/m3
Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. The laboratory formulates opinions and interpretations in test reports for the tests marked with the symbol ←
NDIR method PN-EN 15058:2017-04 ←
87 Automated Measuring Systems (AMS) O2 concentration
Range (0,1 – 25) %
Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. The laboratory formulates opinions and interpretations in test reports for the tests marked with the symbol ←
Paramagnetic method PN-EN 14789:2017-04 ←
88 Automated Measuring Systems (AMS) CO2 concentration
Range (0,1 – 30) %
Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. The laboratory formulates opinions and interpretations in test reports for the tests marked with the symbol ←
NDIR method ISO 12039:2019 ←
89 Automated Measuring Systems (AMS) Water vapour concentration (H2O)
Range (23 − 250) mg/m3 Range (3 – 40) % Range (3,14 − 57)%
Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. The laboratory formulates opinions and interpretations in test reports for the tests marked with the symbol ←
Condensation- adsorption method; Temperature method PN-EN 14790:2017-04 ←
90 Automated Measuring Systems (AMS) HF concentration
Range (0,1 − 200) mg/m3
Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. The laboratory formulates opinions and interpretations in test reports for the tests marked with the symbol ←
Method using an ion-selective electrode ISO 15713:2006 ←
91 Automated Measuring Systems (AMS) HCl concentration
Range (0,1 − 5000) mg/m3
Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. The laboratory formulates opinions and interpretations in test reports for the tests marked with the symbol ←
Spectrophotometric method PN-EN 1911:2011 ←
92 Automated Measuring Systems (AMS) Total mercury concentration
Range (0,0033 – 770) μg/m3
Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. The laboratory formulates opinions and interpretations in test reports for the tests marked with the symbol ←
Cold vapour atomic absorption spectrometry (CVAAS) PN-EN 13211+AC:2006 ←
93 Automated Measuring Systems (AMS) Concentration of organic substances in the form of gases and vapours expressed as total gaseous organic carbon
Range (0,5 – 1000) mg/m3
Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. The laboratory formulates opinions and interpretations in test reports for the tests marked with the symbol ←
Continuous measurement method with flame ionization detection (FID) PN-EN 12619:2013-05 ←
94 Automated Measuring Systems (AMS) AMS calibration (QAL2) for: NH3, N2O, CH2O
Regulated area: The laboratory formulates opinions and interpretations in test reports for the tests marked with the symbol ←
PN-EN 14181:2015 ←
95 Automated Measuring Systems (AMS) Annual surveillance test (AST) for: NH3, N2O, CH2O
Regulated area: The laboratory formulates opinions and interpretations in test reports for the tests marked with the symbol ←
PN-EN 14181:2015 ←
96 Automated Measuring Systems (AMS) NH3 concentration
Range (0,38 − 38) mg/m3
Regulated area: The laboratory formulates opinions and interpretations in test reports for the tests marked with the symbol ←
Fourier transform infrared spectroscopy (FTIR) LBŚ-PB-23 issue 4 of 13.07.2020 ← | ISO 17179:2016
97 Automated Measuring Systems (AMS) N2O concentration
Range (1,97 – 3900) mg/m3
Regulated area: The laboratory formulates opinions and interpretations in test reports for the tests marked with the symbol ←
Fourier transform infrared spectroscopy (FTIR) LBŚ-PB-23 issue 4 of 13.07.2020 ←
98 Automated Measuring Systems (AMS) Ammonia concentration
Range (0,06 – 629) mg/m3
Spectrophotometric method PN-EN ISO 21877:2020-03
99 Automated Measuring Systems (AMS) N2O concentration
Range (0,8 – 980) mg/m3
Regulated area: The laboratory formulates opinions and interpretations in test reports for the tests marked with the symbol ←
Non-dispersive infrared spectrometry (NDIR) PN-EN 21258:2010 ←
100 Automated Measuring Systems (AMS) Formaldehyde concentration
Range (0,035 – 700) mg/m3
Spectrophotometric method CEN/TS 17638:2021
101 Waste gas dedusting equipment Dust concentration
Range (0,0002 – 100) g/m3
Regulated area: The laboratory formulates opinions and interpretations in test reports for the tests marked with the symbol ←
Gravimetric method PN-87/M-34129:1987 – Method A ← | PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02
102 Waste gas dedusting equipment Dust removal efficiency (calculated)
Regulated area: The laboratory formulates opinions and interpretations in test reports for the tests marked with the symbol ←
PN-87/M-34129:1987 – Method A ← | PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02
103 General environment – waste gas samples collected on filters Mercury content
Range (0,01 – 0,125) μg in the sample
Regulated area: * - the method is applicable as a reference method in the regulated area
Cold vapour atomic absorption spectrometry (CVAAS) PN-EN 13211+AC:2006*
104 General environment – waste gas samples collected into absorbing solution Mercury content
Range (0,007 – 87,5) μg in the sample
Regulated area: * - the method is applicable as a reference method in the regulated area
Cold vapour atomic absorption spectrometry (CVAAS) PN-EN 13211+AC:2006*
105 General environment – waste gas samples collected into absorbing solution Hydrogen chloride content
Range (0,02 – 300) mg in the sample
Regulated area: * - the method is applicable as a reference method in the regulated area
Spectrophotometric method PN-EN 1911:2011*
106 General environment – waste gas samples collected into absorbing solution Hydrogen fluoride content
Range (0,01 – 20) mg in the sample
Regulated area: * - the method is applicable as a reference method in the regulated area
Method using an ion-selective electrode ISO 15713:2006*
107 General environment – waste gas samples collected into absorbing solution Ammonia content
Range (0,095 – 236) mg/l in the sample
Spectrophotometric method PN-EN 21877:2020-03
108 General environment – waste gas samples collected into absorbing solution Formaldehyde content
Range (0,0042 – 42) mg in the sample
Spectrophotometric method CEN/TS 17638:2021
109 General environment – waste gas samples collected into absorbing solution Hydrogen sulphide content
Range (0,01 – 11,2) mg in the sample
Spectrophotometric method LBŚ-PB-25 issue 1 of 15.03.2024
110 General environment − noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level
Range (26 – 136) dB
Regulated area: The laboratory formulates opinions and interpretations in test reports for the tests marked with the symbol ←
Direct measurement method Annex No. 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws of 2023, item 1706) excluding point EII1 and point F ←
111 General environment − noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated)
Regulated area: The laboratory formulates opinions and interpretations in test reports for the tests marked with the symbol ←
Annex No. 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws of 2023, item 1706) excluding point EII1 and point F ←
112 Machinery and equipment – noise A-weighted equivalent sound pressure level
Range (26 − 136) dB
Direct measurement method PN-EN ISO 3746:2011 | PN-EN ISO 3746:2011/Ap1:2017-09
113 Machinery and equipment – noise Sound power level (calculated) PN-EN ISO 3746:2011 | PN-EN ISO 3746:2011/Ap1:2017-09
114 Workplace environment − noise A-weighted equivalent sound level Maximum A-weighted sound level
Range (26 – 136) dB C-weighted peak sound pressure level Range (40 – 140) dB
Direct measurement method PN-N-01307:1994 | PN-EN ISO 9612:2011 excluding the method covering strategy 2 - cl. 10 and strategy 3 - cl. 11
115 Workplace environment − noise Noise exposure level referred to:
an 8-hour daily working time the average weekly working time (calculated)
PN-N-01307:1994 | PN-EN ISO 9612:2011 excluding the method covering strategy 2 - cl. 10 and strategy 3 - cl. 11
116 Workplace environment − lighting Illuminance
Range (0,5 – 9 750) lx
Direct measurement method LBŚ-PB-14 issue 4 of 30.06.2025 | PN-83/E-04040.03
117 Workplace environment − lighting Illuminance uniformity (calculated) LBŚ-PB-14 issue 4 of 30.06.2025 | PN-83/E-04040.03
118 Workplace environment − whole-body vibration Frequency-weighted r.m.s. vibration acceleration
Range (0,053 – 100) m/s2
Direct measurement method PN-EN 14253+A1:2011
119 Workplace environment − whole-body vibration Daily exposure, expressed as the energy-equivalent for 8 hours of the r.m.s., frequency-weighted vibration acceleration, dominant among the vibration accelerations, determined for the three directional components taking into account the appropriate factors (1,4awx, 1,4awy, awz), Exposure lasting 30 minutes and less, expressed as the r.m.s., frequency-weighted vibration acceleration, dominant among the vibration accelerations, determined for the three directional components taking into account the appropriate factors (1,4awx, 1,4awy, awz) (calculated) PN-EN 14253+A1:2011
120 Workplace environment - moderate microclimate Air temperature
Range (10 – 50) 0C Black globe temperature Range (10 – 50) 0C Air humidity Range (25 – 75) % Air velocity Range (0,20 – 5) m/s
Direct measurement method PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04
121 Workplace environment - moderate microclimate PMV and PPD index (calculated) PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04
122 Workplace environment - hot microclimate Air temperature
Range (10 – 50) 0C Natural wet bulb temperature Range (10 – 50) 0C Black globe temperature Range (10 – 50) 0C
Direct measurement method PN-EN ISO 7243:2018-01 | PN-EN ISO 7243:2018-01/Ap2:2020-04
123 Workplace environment - hot microclimate WBGT index, WBGTeff index (calculated) PN-EN ISO 7243:2018-01 | PN-EN ISO 7243:2018-01/Ap2:2020-04
124 Workplace environment − air Sampling for assessment of occupational exposure:
dust agents inhalable fraction respirable fraction metals and their compounds, including inhalable fraction respirable fraction organic substances, including inhalable fraction inorganic substances, including inhalable fraction respirable fraction thoracic fraction
Personal dosimetry method PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004
125 Workplace environment − air Sampling for assessment of occupational exposure:
inorganic substances, including inhalable fraction respirable fraction thoracic fraction
Stationary method PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004
126 Workplace environment − air Exposure index (calculated) PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004
127 Workplace environment − air Concentration of harmful dust agents - inhalable fraction
Petroleum bitumen Apatites and phosphorites Portland cement Titanium dioxide Natural graphite Synthetic graphite Kaolin Amorphous and synthetic silica Wood dusts Flour dusts Dusts not classified according to toxicity Organic dusts of animal and plant origin, excluding wood and flour dusts Calcium sulfate (VI) (gypsum) Carbon black Talc Coal (hard, brown) Calcium magnesium carbonate (dolomite) Silicon carbide, non-fibrous Range (0,08 – 81,6) mg/m3 Range (0,06 – 2,45) mg in the sample
Gravimetric method PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08
128 Workplace environment − air Concentration of harmful dust agents - respirable fraction
Apatites and phosphorites Portland cement Natural graphite Amorphous and synthetic silica Organic dusts of animal and plant origin, excluding wood and flour dusts Talc Coal (hard, brown) Range (0,05 – 43,8) mg/m3 Range (0,05 – 5,0) mg in the sample
Gravimetric method PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08
129 Workplace environment − air Concentration of highly refined mineral oils excluding metalworking fluids
inhalable fraction Range (0,42 – 22,2) mg/m3
UV spectrophotometry method PN-Z-04108-6:2006+Az1:2009
130 Workplace environment − air Carbon monoxide concentration
Range (2,3 – 250) mg/m3 Range (2,00 – 215) ppm
Electrochemical method LBŚ-PB-12 issue 4 of 30.06.2025
131 Workplace environment − air Nitrogen oxide concentration
Range (0,012 – 11,56) mg/m3 Range (0,0096 – 9,28) ppm
Spectrophotometric method PN-Z-04009-11:2008
132 Workplace environment − air Nitrogen dioxide concentration
Range (0,018 – 17,78) mg/m3 Range (0,0094 – 9,31) ppm
Spectrophotometric method PN-Z-04009-11:2008
133 Workplace environment − air Hydrogen chloride concentration/content
Range (0,5 – 50,0) mg/m3 Range (0,2 – 20,0) mg in the sample
Turbidimetric method PN-Z-04450:2014-08
134 Workplace environment − air Sulphur dioxide concentration/content
Range (0,13 − 6,40) mg/m3 Range (0,049 – 2,41) ppm Range (0,0032 – 0,064) mg in the sample
Spectrophotometric method PN-Z-04015-12:1996+Ap1:2001
135 Workplace environment − air Ammonia concentration/content
Range (1,3 – 60) mg/m3 Range (0,02 – 0,2) mg in the sample
Spectrophotometric method PN-71/Z-04041
136 Workplace environment − air Concentration / content of crystalline silica - quartz; cristobalite
respirable fraction Range (0,0093 – 0,58) mg/m3 Range (0,01 – 0,4) mg in the sample
Fourier transform infrared spectrometry (FT-IR) Principles and Methods of Assessing the Working Environment 2012, No. 4 (74), pp. 117–130
137 Groundwater Sampling for chemical and physical testing PN-ISO 5667-11:2017-10 excluding cl. 5.2, 6.1.2, 6.2, 6.3
138 Groundwater Temperature
Range (0,5 – 50,0) °C
PN-77/C-04584
139 Wastewater, Rainwater, Snowmelt water Sampling for chemical and physical testing Manual method PN-ISO 5667-10:2021-11
140 Wastewater, Rainwater, Snowmelt water Temperature
Range (0,5 – 50,0) °C
PN-77/C-04584
141 Surface water Sampling for chemical and physical testing Manual method PN-EN ISO 5667-6:2016-12 excluding cl. 7.6 | PN-EN ISO 5667-6:2016-12 /A11:2020-10
142 Surface water Temperature
Range (0,5 – 50,0) °C
PN-77/C-04584
143 Water, Wastewater pH
Range (2,0 – 12)
Regulated area: + Tests performed at and outside the laboratory premises
Potentiometric method PN-EN ISO 10523:2012
144 Water, Wastewater Electrical conductivity
Range (5 – 12900) μS/cm
Regulated area: + Tests performed at and outside the laboratory premises
Conductometric method PN-EN 27888:1999
145 Water, Wastewater Total alkalinity Composite alkalinity
Range (0,40 – 20) mmol/l Range (0,20 – 10) mmol/l CaCO3
Titrimetric method PN-EN ISO 9963-1:2001+Ap1:2004
146 Water, Wastewater Bicarbonate (HCO3-) concentration (calculated) PN-EN ISO 9963-1:2001+Ap1:2004
147 Water, Wastewater Total acidity
Range (0,05 – 5) mmol/l
Titrimetric method PN-90/C-04540/03+Az1:2003
148 Water, Wastewater Total content of calcium and magnesium (total hardness)
Range (0,05 – 10) mmol/l Range (5 – 1000) mg/l CaCO3
Titrimetric method PN-ISO 6059:1999
149 Water, Wastewater Calcium concentration
Range (0,05 – 10) mmol/l Range (2 – 400) mg/l Ca
Titrimetric method PN-ISO 6058:1999
150 Water, Wastewater Iron concentration
Range (0,02 – 25) mg/l
Spectrophotometric method PN-ISO 6332:2001
151 Water, Wastewater Orthophosphate concentration
Range (0,04 – 6,4) mg/l
Spectrophotometric method PN-EN ISO 6878:2006+Ap1:2010 + Ap2:2010 cl. 4
152 Water, Wastewater Total phosphorus concentration
Range (0,04 – 8,0) mg/l
Spectrophotometric method PN-EN ISO 6878:2006+Ap1:2010 + Ap2:2010 cl. 7
153 Water, Wastewater Chemical oxygen demand COD-Cr
Range (30 – 700) mg/l
Titrimetric method PN ISO 6060:2006
154 Water, Wastewater Dissolved solids
Range (40 – 2000) mg/l
Gravimetric method PN-EN 15216:2022-03
155 Water, Wastewater Dry residue
Range (40 – 2500) mg/l
Gravimetric method PN-78/C-04541
156 Water, Wastewater, Rainwater, Snowmelt water Total suspended solids (TSS)
Range (2,0 – 1000) mg/l
Gravimetric method PN-EN 872:2007+Ap1:2007
157 Water, Wastewater Chloride concentration
Range (5,0 − 1000) mg/l
Titrimetric method PN-ISO 9297:1994
158 Water, Wastewater Sulfate concentration
Range (10,0 1000) mg/l
Gravimetric method PN-ISO 9280:2002
159 Water, Wastewater Fluoride concentration
range (0,10 - 10) mg/l
Potentiometric method PN-78/C-04588.03
160 Water, Wastewater Nitrate nitrogen concentration
Range (0,10 – 50) mg/l Nitrate concentration Range (0,44 - 221) mg/l
Spectrophotometric method PN-82/C-04576.08
161 Water, Wastewater Nitrite nitrogen concentration
range (0,006 – 3,0) mg/l Nitrite concentration Range (0,02 – 10,0) mg/l
Spectrophotometric method PN-EN 26777:1999
162 Water, Wastewater Ammonium nitrogen concentration
Range (0,025 – 40,0) mg/l Ammonium ion concentration Range (0,032 – 51,6) mg/l
Spectrophotometric method PN-ISO 7150-1:2002
163 Water, Wastewater Mercury concentration
Range (0,1 – 1250) μg/l
Cold vapour atomic absorption spectrometry (CVAAS) PN-EN ISO 12846:2012+Ap1:2016-07

Reference standards (93)

CEN/TR 17078:2017-03
CEN/TS 17638:2021
ISO 11338-1:2003 – Method B ←
ISO 12039:2019 ←
ISO 15713:2006 ←
ISO 15713:2006*
ISO 17179:2016
LBŚ-IR-36 issue 6 of 11.03.2024
LBŚ-PB-12 issue 4 of 30.06.2025
LBŚ-PB-14 issue 4 of 30.06.2025
LBŚ-PB-22 issue 4 of 30.11.2016
LBŚ-PB-23 issue 4 of 13.07.2020 ←
LBŚ-PB-24 issue 3 of 17.10.2022 ←
LBŚ-PB-25 issue 1 of 15.03.2024
PN ISO 6060:2006
PN-71/Z-04041
PN-77/C-04584
PN-78/C-04541
PN-78/C-04588.03
PN-82/C-04576.08
PN-83/E-04040.03
PN-87/M-34129:1987 – Method A ←
PN-90/C-04540/03+Az1:2003
PN-EN 12619:2013-05 ←
PN-EN 13211+AC:2006 ←
PN-EN 13211+AC:2006*
PN-EN 13284-1:2018-02
PN-EN 13284-1:2018-02 ←
PN-EN 13649:2005 ←
PN-EN 14181:2015 ←
PN-EN 14253+A1:2011
PN-EN 14385:2025 -05 ←
PN-EN 14385:2025-05 ←
PN-EN 14789:2017-04 ←
PN-EN 14790:2017-04 ←
PN-EN 14791:2017-04 ←
PN-EN 14792:2017-04 ←
PN-EN 15058:2017-04 ←
PN-EN 15216:2022-03
PN-EN 1911:2011 ←
PN-EN 1911:2011*
PN-EN 1948-1:2006
PN-EN 1948-4+A1:2014-03
PN-EN 21258:2010 ←
PN-EN 21877:2020-03
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10523:2012
PN-EN ISO 12846:2012+Ap1:2016-07
PN-EN ISO 16911-1:2013
PN-EN ISO 21258:2010 ←
PN-EN ISO 21877:2020-03
PN-EN ISO 23210:2010 ←
PN-EN ISO 25139:2011 ←
PN-EN ISO 3746:2011
PN-EN ISO 3746:2011/Ap1:2017-09
PN-EN ISO 5667-6:2016-12 /A11:2020-10
PN-EN ISO 5667-6:2016-12 excluding cl. 7.6
PN-EN ISO 6878:2006+Ap1:2010 + Ap2:2010 cl. 4
PN-EN ISO 6878:2006+Ap1:2010 + Ap2:2010 cl. 7
PN-EN ISO 7243:2018-01
PN-EN ISO 7243:2018-01/Ap2:2020-04
PN-EN ISO 7730:2006
PN-EN ISO 7730:2006/Ap2:2016-04
PN-EN ISO 9612:2011 excluding the method covering strategy 2 - cl. 10 and strategy 3 - cl. 11
PN-EN ISO 9963-1:2001+Ap1:2004
PN-ISO 10396:2001
PN-ISO 10396:2001 ←
PN-ISO 5667-10:2021-11
PN-ISO 5667-11:2017-10 excluding cl. 5.2, 6.1.2, 6.2, 6.3
PN-ISO 6058:1999
PN-ISO 6059:1999
PN-ISO 6332:2001
PN-ISO 7150-1:2002
PN-ISO 7935:2000
PN-ISO 9280:2002
PN-ISO 9297:1994
PN-N-01307:1994
PN-Z-04008-7:2002
PN-Z-04008-7:2002/Az1:2004
PN-Z-04009-11:2008
PN-Z-04015-12:1996+Ap1:2001
PN-Z-04030-7:1994
PN-Z-04030-7:1994 ←
PN-Z-04108-6:2006+Az1:2009
PN-Z-04450:2014-08
PN-Z-04507:2022-05
PN-Z-04507:2022-05/Ap1:2022-08
PN-Z-04508:2022-05
PN-Z-04508:2022-05/Ap1:2022-08
Principles and Methods of Assessing the Working Environment 2012, No. 4 (74), pp. 117–130
Annex No. 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws of 2023, item 1706) excluding point EII1 and point F ←

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/PL/AB%20782