🇵🇱 WODOCIĄGI I KANALIZACJA Sp. z o.o. PL

PCA AB 756 • Dzierżoniów, Poland • 43 methods

Water & wastewaterMicrobiology

WODOCIĄGI I KANALIZACJA Sp. z o.o. is a laboratory accredited by PCA under number AB 756 (Dzierżoniów, Poland). Its accreditation scope covers 43 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water, Water intended for human consumption, Wastewater, Water, Wastewater, Water. Most frequently used techniques: Spectrophotometric method, Membrane filtration method, Titrimetric method.

At a glance

  • Accreditation number: PCA AB 756
  • Methods in scope: 43
  • Types of test objects: 6
  • Techniques used: 13
  • City: Dzierżoniów, Poland
Accreditation number
AB 756
Accreditation body
PCA
Address
ul. Kilińskiego 25 A, 58-200 Dzierżoniów, DZIAŁ LABORATORIUM, ul. Relaksowa 5, 58-200 Dzierżoniów
City
Dzierżoniów, Poland

What this laboratory tests (6)

Analytical techniques used (13)

Laboratory locations

Certificate information

Issue date
23.07.2026
Issue no.
18

Accreditation scope — test methods (43)

No. Test object Methodology / Parameters Technique Reference document
Laboratory department
1 Wastewater Sampling for chemical and physical testing. Manual method; Automatic method PN- ISO 5667-10:2021-11
2 Wastewater pH
Range 4,0 – 10,0
Regulated area: + Tests performed at and outside the laboratory premises
Potentiometric method PN-EN ISO 10523:2012
3 Wastewater Ammonium nitrogen concentration
Range (0,10 – 110) mg/l
Spectrophotometric method PL-B-07 issue 3 of 04.05.2010 | based on Merck test No. 1147520001
4 Wastewater Nitrate nitrogen concentration
Range (0,50 – 25,0) mg/l
Spectrophotometric method PL-B-06 issue 3 of 04.05.2010 | based on Merck test No. 1097130001
5 Wastewater Total phosphorus concentration
Range (0,05 – 45) mg/l
Spectrophotometric method PL-B-04 issue 5 of 01.06.2018 | based on Merck test No. 1148480001
6 Wastewater Chloride concentration
Range (2,0 – 1000) mg/l
Titrimetric method PN-ISO 9297:1994
7 Wastewater Sulfate concentration
Range (20 – 1000) mg/l
Turbidimetric method PL-B-05 issue 5 of 22.05.2023 | based on Merck test No. 1145480001 and HACH LANGE No. 8051
8 Wastewater Chemical oxygen demand
COD Range (4,00 – 5000) mg/l O2
Spectrophotometric method PN-ISO 15705:2005
9 Water, Water intended for human consumption, Wastewater Electrical conductivity
Range (100 – 3000) μS/cm
Regulated area: + Tests performed at and outside the laboratory premises
Conductometric method PN-EN 27888:1999
10 Water, Wastewater Total nitrogen concentration
Range (0,50 – 150) mg/l
Spectrophotometric method PL-B-10 issue 3 of 19.05.2016 | based on Merck test No. 1006130001 and 1147630001
11 Water, Wastewater Total suspended solids (TSS)
Range (2,0 – 5000) mg/l
Gravimetric method PN-EN 872:2007+Ap1:2007
12 Water, Wastewater Dissolved oxygen concentration
Range (1,0 – 15,0) mg/l O2
Electrochemical method PN-EN ISO 5814:2013-04
13 Water, Wastewater Biochemical oxygen demand
BOD5 Range (3,0 – 2000) mg/l O2
Electrochemical method PN-EN ISO 5815-1:2019:12
14 Water, Wastewater Biochemical oxygen demand
BOD5 Range (1,0 – 6,0) mg/l O2
Electrochemical method PN-EN 1899-2:2002
15 Water, Water intended for human consumption Sampling for chemical and physical testing PN-ISO 5667-5:2017-10
16 Water, Water intended for human consumption Turbidity
Range (0,10 – 100) NTU
Nephelometric method PN-EN ISO 7027-1:2016-09
17 Water, Water intended for human consumption Free chlorine concentration
Range (0,040 – 2,00) mg/l
Regulated area: + Tests performed at and outside the laboratory premises
Spectrophotometric method PL-B-12 issue 2 of 02.06.2017
18 Water, Water intended for human consumption Permanganate index
Range (0,50 – 10) mg/l
Titrimetric method PN-EN ISO 8467:2001
19 Water, Water intended for human consumption pH
Range 4,0 – 10,0
Potentiometric method PN-EN ISO 10523:2012
20 Water, Water intended for human consumption Ammonium ion concentration
Range (0,040 – 0,60) mg/l
Spectrophotometric method PL-B-07 issue 3 of 04.05.2010 | based on Merck test No. 1147520001
21 Water, Water intended for human consumption Nitrate concentration
Range (2,20– 70,0) mg/l
Spectrophotometric method PL-B-06 issue 3 of 04.05.2010 | based on Merck test No. 1097130001
22 Water, Water intended for human consumption Phosphate concentration
Range (0,10 – 3,00) mg/l
Spectrophotometric method PL-B-04 issue 5 of 01.06.2018 | based on Merck test No. 1148480001
23 Water, Water intended for human consumption Total hardness (Total concentration of calcium and magnesium)
Range (5,0 – 1000 mg) mg/l
Titrimetric method PN-ISO 6059:1999
24 Water, Water intended for human consumption Calcium concentration
Range (2,0 – 200) mg/l
Titrimetric method PN-ISO 6058:1999
25 Water, Water intended for human consumption Magnesium concentration method (calculated) PN-C-04554-4:1999, Annex A
26 Water, Water intended for human consumption Total iron concentration
Range (0,030 – 5,0) mg/l
Spectrophotometric method PL-B-01 issue 5 of 04.05.2010 | based on Merck test No. 1147610001
27 Water, Water intended for human consumption Manganese concentration
Range (0,010 – 2,00) mg/l
Spectrophotometric method PL-B-16 issue 1 of 12.05.2014 | based on HACH LANGE test No. 032
28 Water, Water intended for human consumption Aluminium concentration
Range (0,060 – 0,70) mg/l
Spectrophotometric method PL-B-09 issue 2 of 04.05.2010 | based on Merck test No. 1148250001
29 Water, Water intended for human consumption Chloride concentration
Range (2,00– 250) mg/l
Titrimetric method PN-ISO 9297:1994
30 Water, Water intended for human consumption Sulfate concentration
Range (10 – 250) mg/l
Turbidimetric method PL-B-05 issue 5 of 22.05.2023 | based on Merck test No. 1145480001 and HACH LANGE No. 8051
31 Water, Water intended for human consumption Colour
Range (4 – 100) mg/l Pt/Co
Spectrophotometric method PN-EN ISO 7887:2012 Method C+Ap1:2015-06
32 Water Chemical oxygen demand
COD Range (4,00 – 150) mg/l O2
Spectrophotometric method PN-ISO 15705:2005
33 Water, Water intended for human consumption Sampling for microbiological testing PN-EN ISO 19458:2007, excluding cl. 4.4.3, 4.4.4.1, 4.4.5, 4.4.6
34 Water, Water intended for human consumption Total microorganism count at a temperature of 22°C Plate method, pour plate PN-EN ISO 6222:2004
35 Water, Water intended for human consumption Total microorganism count at 36°C Plate method, pour plate PN-EN ISO 6222:2004
36 Water, Water intended for human consumption Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004
37 Water, Water intended for human consumption Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12+A1:2017-04
38 Water, Water intended for human consumption Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12+A1:2017-04
39 Water, Water intended for human consumption Most probable number of coliform bacteria MPN method PN-EN ISO 9308-2:2014-06
40 Water, Water intended for human consumption Most probable number of Escherichia coli MPN method PN-EN ISO 9308-2:2014-06
41 Water, Water intended for human consumption Clostridium perfringens count (including spores) Membrane filtration method PN-EN ISO 14189:2016-10
42 Water Count of bacteria of the genus Legionella, Matrix B, Procedure 7 (medium C-GVPC) Membrane filtration method PN-EN ISO 11731:2017-08+Ap1:2019-12
43 Water intended for human consumption Most probable number of Pseudomonas aeruginosa MPN method PN-EN ISO 16266-2:2022-04

Reference standards (42)

PL-B-01 issue 5 of 04.05.2010
PL-B-04 issue 5 of 01.06.2018
PL-B-05 issue 5 of 22.05.2023
PL-B-05 issue 5 of 22.05.2023
PL-B-06 issue 3 of 04.05.2010
PL-B-07 issue 3 of 04.05.2010
PL-B-09 issue 2 of 04.05.2010
PL-B-10 issue 3 of 19.05.2016
PL-B-12 issue 2 of 02.06.2017
PL-B-16 issue 1 of 12.05.2014
PN- ISO 5667-10:2021-11
PN-C-04554-4:1999, Annex A
PN-EN 1899-2:2002
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10523:2012
PN-EN ISO 11731:2017-08+Ap1:2019-12
PN-EN ISO 14189:2016-10
PN-EN ISO 16266-2:2022-04
PN-EN ISO 19458:2007, excluding cl. 4.4.3, 4.4.4.1, 4.4.5, 4.4.6
PN-EN ISO 5814:2013-04
PN-EN ISO 5815-1:2019:12
PN-EN ISO 6222:2004
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7887:2012 Method C+Ap1:2015-06
PN-EN ISO 7899-2:2004
PN-EN ISO 8467:2001
PN-EN ISO 9308-1:2014-12+A1:2017-04
PN-EN ISO 9308-2:2014-06
PN-ISO 15705:2005
PN-ISO 5667-5:2017-10
PN-ISO 6058:1999
PN-ISO 6059:1999
PN-ISO 9297:1994
based on HACH LANGE test No. 032
based on Merck test No. 1006130001 and 1147630001
based on Merck test No. 1097130001
based on Merck test No. 1145480001 and HACH LANGE No. 8051
based on Merck test No. 1147520001
based on Merck test No. 1147610001
based on Merck test No. 1148250001
based on Merck test No. 1148480001

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/PL/AB%20756