🇵🇱 KATALIZATOR Sp. z o.o. PL
Environment
KATALIZATOR Sp. z o.o. is a laboratory accredited by PCA under number AB 753 (Kraków, Poland). Its accreditation scope covers 83 test methods in the following areas: Environment. Test objects include: Waste gases, Automated Measuring Systems (AMS), General environment – noise from installations, equipment and indus…, Waste gas dedusting equipment. Most frequently used techniques: Non-dispersive infrared spectrometry (NDIR), Gravimetric method, Aspiration method.
At a glance
- Accreditation number: PCA AB 753
- Methods in scope: 83
- Types of test objects: 4
- Techniques used: 22
- City: Kraków, Poland
- Accreditation number
- AB 753
- Accreditation body
- PCA
- Address
- ul. Torowa 3s, 30-435 Kraków
- City
- Kraków, Poland
What this laboratory tests (4)
- Waste gases — 59 methods
- Automated Measuring Systems (AMS) — 20 methods
- General environment – noise from installations, equipment and industrial plants — 2 methods
- Waste gas dedusting equipment — 2 methods
Analytical techniques used (22)
- Non-dispersive infrared spectrometry (NDIR) — 7 methods
- Gravimetric method — 4 methods
- Aspiration method — 3 methods
- Chemiluminescence method — 2 methods
- Condensation method — 2 methods
- Continuous flame ionization detection method (FID) — 2 methods
- Paramagnetic method — 2 methods
- Spectrophotometric method — 2 methods
- Thoron method — 2 methods
- Absorption method — 1 method
- Anemometric method — 1 method
- Aspiration method using adsorbents and absorbing solutions — 1 method
- Differential pressure measurement method — 1 method
- Direct measurement method — 1 method
- Fourier transform infrared spectrometry (FTIR) — 1 method
- and 7 more
Laboratory locations
- KATALIZATOR Sp. z o.o. (main site) — ul. Torowa 3s, 30-435 Kraków
- Environmental Testing Laboratory — ul. Torowa 3s, 30-435 Kraków
Certificate information
- Issue date
- 29.06.2026
- Issue no.
- 23
Accreditation scope — test methods (83)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Environmental Testing Laboratory | |||||
| 1 | Waste gases | Gas volume flow rate for dynamic pressures > 10 Pa Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Stagnation pressure method | PN-Z-04030-7:1994 | |
| 2 | Waste gases | Velocity Range (2 - 20) m/s Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Anemometric method | PN-Z-04030-7:1994 | |
| 3 | Waste gases | Sampling for determination of dust concentration Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
PN-Z-04030-7:1994 | ||
| 4 | Waste gases | Dust concentration Range (1 - 100000) mg/m3 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Gravimetric method | PN-Z-04030-7:1994 | |
| 5 | Waste gases | Dust emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
PN-Z-04030-7:1994 | ||
| 6 | Waste gases | Gas velocity and volumetric flow rate for differential pressures >5 Pa Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Differential pressure measurement method | PN-EN-ISO 16911-1:2013-07 | |
| 7 | Waste gases | Sampling for determination of dust concentration Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
PN-EN 13284-1:2018-02 | ||
| 8 | Waste gases | Dust concentration Range (0,3 - 50) mg/m3 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Gravimetric method | PN-EN 13284-1:2018-02 | |
| 9 | Waste gases | Dust emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
PN-EN 13284-1:2018-02 | ||
| 10 | Waste gases | Sampling for the determination of HCl concentration Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
PN-EN 1911:2011 | ||
| 11 | Waste gases | HCl concentration Range (1,0 - 500) mg/m3 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Spectrophotometric method | PN-EN 1911:2011 | |
| 12 | Waste gases | HCl emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
PN-EN 1911:2011 | ||
| 13 | Waste gases | Sampling for determination of HF concentration Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
ISO 15713:2006 | CEN/TS 17340:2020-09 | ||
| 14 | Waste gases | HF concentration Range (0,1 - 200) mg/m3 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Potentiometric method | ISO 15713:2006 | CEN/TS 17340:2020-09 | |
| 15 | Waste gases | HF emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
ISO 15713:2006 | CEN/TS 17340:2020-09 | ||
| 16 | Waste gases | Concentration of organic substances in the form of gases and vapours expressed as total gaseous organic carbon Range (0,3 - 1000) mg/m3 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Continuous flame ionization detection method (FID) | PN-EN 12619:2013-05 | |
| 17 | Waste gases | Emission of organic substances in gaseous and vapour form expressed as total gaseous organic carbon (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
PN-EN 12619:2013-05 | ||
| 18 | Waste gases | Sampling for the determination of metal concentrations (As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
PN-EN 14385:2025-05 | ||
| 19 | Waste gases | Emission of metals (As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V) (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
PN-EN 14385:2025-05 | ||
| 20 | Waste gases | Sampling for determination of total mercury concentration (Hg) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Aspiration method | PN-EN 13211:2006 | |
| 21 | Waste gases | Emission of total mercury (Hg) (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
PN-EN 13211:2006 | ||
| 22 | Waste gases | CO2, CO, NO, NO2, SO2, O2 concentration, CO2 (1,0 - 24,0) % vol. CO (4,0 - 8060,0) mg/m3 NO (2,0 - 1000,0) mg/m3 NO2 (3,0 - 200,0) mg/m3 SO2 (6 - 3000) mg/m3 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
FTIR method | PN-ISO 10396:2001 | |
| 23 | Waste gases | Concentration of SO2, CO, CO2, O2, NOx SO2 (2,9 - 2800,0) mg/m3 CO (1,3 - 6300,0) mg/m3 CO2 (1,0 - 20,0) % vol. NO (1,9 - 1450,0) mg/m3 NOx (2,8 - 2100,0) mg/m3 O2 (1,0 - 23,0) % vol. O2 (1,0 - 25,0) % vol. O2 (1,0 - 25,0) % vol. Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Non-dispersive infrared spectrometry method (NDIR); Paramagnetic method (PMD); Zirconia cell method; Electrochemical method | PN-ISO 10396:2001 | |
| 24 | Waste gases | Emission of CO2, CO, NO, NO2, NOx (NO and NO2 calculated as NO2), SO2 (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
PN-ISO 10396:2001 | ||
| 25 | Waste gases | Water vapour concentration (H2O) Range (4,0 - 40,0) % Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Condensation method | PN-EN 14790:2017 | |
| 26 | Waste gases | NOx, NO concentration NOx (2,0 - 2200,0) mg/m3 NO (1,2 - 1500,0) mg/m3 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Chemiluminescence method | PN-EN 14792:2017 | |
| 27 | Waste gases | NO, NOx emission (NO and NO2 calculated as NO2) (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
PN-EN 14792:2017 | ||
| 28 | Waste gases | O2 concentration Range (1,0 - 25,0) % Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Paramagnetic method | PN-EN 14789:2017 | |
| 29 | Waste gases | CO concentration Range (1,0 - 3000) mg/m3 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Non-dispersive infrared spectrometry (NDIR) | PN-EN 15058:2017 | |
| 30 | Waste gases | CO emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
PN-EN 15058:2017 | ||
| 31 | Waste gases | Sampling for determination of SO2 concentration Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
PN-EN 14791:2017-04 | ||
| 32 | Waste gases | SO2 concentration Range (5,0 - 5000) mg/m3 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Thoron method | PN-EN 14791:2017-04 | |
| 33 | Waste gases | SO2 emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
PN-EN 14791:2017-04 | ||
| 34 | Waste gases | Sampling for determination of the mass concentration of PCDD/PCDFs Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
PN-EN 1948-1:2006 | ||
| 35 | Waste gases | Emission of PCDD/PCDFs, (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
PN-EN 1948-1:2006 | ||
| 36 | Waste gases | Waste gas sampling for determination of the concentration of organic compounds. Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Aspiration method using adsorbents and absorbing solutions | PN-Z-04008-4:1999 | |
| 37 | Waste gases | Emission of organic compounds (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
PN-Z-04008-4:1999 | ||
| 38 | Waste gases | Sampling for determination of the concentration of individual gaseous organic compounds. Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Aspiration method | PN-EN 13649:2005 | |
| 39 | Waste gases | Emission of individual gaseous organic compounds (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
PN-EN 13649:2005 | ||
| 40 | Waste gases | CO2 concentration Range (1 - 22) % Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Non-dispersive infrared spectrometry (NDIR) | ISO 12039:2019 | |
| 41 | Waste gases | CO2 emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
ISO 12039:2019 | ||
| 42 | Automated Measuring Systems (AMS) | AMS calibration (QAL2) for: dust, CO2, TVOC, HCl, HF, CO, NOx, NO, NO2, SO2, H2O, O2, Hg, NH3, N2O Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
PN-EN 14181:2015-02 | ||
| 43 | Automated Measuring Systems (AMS) | Annual surveillance tests (AST) for: dust, CO2, TVOC, HCl, HF, CO, NOx, NO, NO2, SO2, H2O, O2, Hg, NH3, N2O Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
PN-EN 14181:2015-02 | ||
| 44 | Automated Measuring Systems (AMS) | Dust concentration Range (0,3 - 50,0) mg/m3 Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Gravimetric method | PN-EN 13284-1:2018-02 | |
| 45 | Automated Measuring Systems (AMS) | CO2 concentration Range (1,0 - 24,0) % vol. Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Fourier transform infrared spectrometry (FTIR) | PN-ISO 10396:2001 | |
| 46 | Automated Measuring Systems (AMS) | Concentration of organic substances in the form of gases and vapours expressed as total gaseous organic carbon Range (0,3 - 1000) mg/m3 Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Continuous flame ionization detection method (FID) | PN-EN 12619:2013-05 | |
| 47 | Automated Measuring Systems (AMS) | HF concentration Range (0,1 - 200) mg/m3 Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Ion-selective electrode method | ISO 15713:2006 | CEN/TS 17340:2020-09 | |
| 48 | Automated Measuring Systems (AMS) | HCl concentration Range (1,0 - 500) mg/m3 Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Spectrophotometric method | PN-EN 1911:2011 | |
| 49 | Automated Measuring Systems (AMS) | CO concentration Range (1,0 - 3000) mg/m3 Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Non-dispersive infrared spectrometry (NDIR) | PN-EN 15058:2017 | |
| 50 | Automated Measuring Systems (AMS) | Water vapour concentration (H2O) Range (4,0 - 40,0) % Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Condensation method | PN-EN 14790:2017 | |
| 51 | Automated Measuring Systems (AMS) | O2 concentration Range (1,0 - 25,0) % Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Paramagnetic method | PN-EN 14789:2017 | |
| 52 | Automated Measuring Systems (AMS) | NOx, NO concentration NOx (2,0 - 2200,0) mg/m3 NO (1,2 - 1500,0) mg/m3 Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Chemiluminescence method | PN-EN 14792:2017 | |
| 53 | Automated Measuring Systems (AMS) | SO2 concentration Range (5,0 - 5000) mg/m3 Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Thoron method | PN-EN 14791:2017-04 | |
| 54 | Waste gases | Dust sampling for particle size determinations | PB/01/05:20.05.2024 | ||
| 55 | Waste gases | Emission of dust fractions PM10, PM2,5 (calculated) | PB/01/05:20.05.2024 | ||
| 56 | Waste gases | Sampling for the determination of the concentration of metals (Fe, Se, Sn, Ti, Zn) | PN-EN 14385:2025-05 | ||
| 57 | Waste gases | Emission of metals (Fe, Se, Sn, Ti, Zn) (calculated) | PN-EN 14385:2025-05 | ||
| 58 | Waste gases | Sampling for determination of the mass concentration of dioxin-like PCBs | PN-EN 1948-4+A1:2014-3 | ||
| 59 | Waste gases | PCB emission (calculated) | PN-EN 1948-4+A1:2014-3 | ||
| 60 | Waste gases | Sampling for the determination of ammonia (NH3) concentration | Manual method | PN-EN ISO 21877:2020-03 | |
| 61 | Waste gases | Ammonia (NH3) emission (calculated) | PN-EN ISO 21877:2020-03 | ||
| 62 | Waste gases | Sampling for determination of hydrogen sulfide concentration (H2S) | Absorption method | PB/04/01:19.02.2024 | |
| 63 | Waste gases | Hydrogen sulfide (H2S) emission (calculated) | PB/04/01:19.02.2024 | ||
| 64 | Waste gases | Sampling for determination of the mass concentration of brominated flame retardants | PN-EN 1948-1:2006 | PN-EN 1948-4+A1:2014-3 | PB/03/01:19.02.2024 | ||
| 65 | Waste gases | Emission of brominated flame retardants (calculated) | PN-EN 1948-1:2006 | PN-EN 1948-4+A1:2014-3 | PB/03/01:19.02.2024 | ||
| 66 | Waste gases | Sampling for determination of benzo(a)pyrene concentration | PB/06/01:01.02.2025 | ||
| 67 | Waste gases | Emission of benzo(a)pyrene (calculated) | PB/06/01:01.02.2025 | ||
| 68 | Waste gases | N2O concentration Range (2,0 - 400,0) mg/m3 |
Non-dispersive infrared spectrometry (NDIR) | PN-EN ISO 21258:2010 | |
| 69 | Waste gases | N2O emission (calculated) | PN-EN ISO 21258:2010 | ||
| 70 | Waste gases | CO2 concentration Range (1 - 22) % |
Non-dispersive infrared spectrometry (NDIR) | ISO 12039:2019 | |
| 71 | Waste gases | CO2 emission (calculated) | ISO 12039:2019 | ||
| 72 | Waste gas dedusting equipment | Dust concentration Range (1 - 100000) mg/m3 |
Gravimetric method | PN-Z-04030-7:1994 | PN-87/M-34129 Method A | |
| 73 | Waste gas dedusting equipment | Dust removal efficiency (calculated) | PN-Z-04030-7:1994 | PN-87/M-34129 Method A | ||
| 74 | Automated Measuring Systems (AMS) | AMS calibration (QAL2) for: NH3, NO2, N2O | PN-EN 14181:2015-02 | ||
| 75 | Automated Measuring Systems (AMS) | Annual surveillance tests (AST) for: NH3, NO2, N2O | PN-EN 14181:2015-02 | ||
| 76 | Automated Measuring Systems (AMS) | NO2 concentration, NO2 (3,0 - 200) mg/m3 |
Fourier transform infrared spectrometry method (FTIR) | PN-ISO 10396:2001 | |
| 77 | Automated Measuring Systems (AMS) | Sampling for the determination of ammonia (NH3) concentration | PN-EN ISO 21877:2020-03 | ||
| 78 | Automated Measuring Systems (AMS) | Sampling for determination of total mercury concentration (Hg) | Aspiration method | PN-EN 13211:2006 | |
| 79 | Automated Measuring Systems (AMS) | Emission of total mercury (Hg) (calculated) | PN-EN 13211:2006 | ||
| 80 | Automated Measuring Systems (AMS) | N2O concentration Range (2,0 - 400,0) mg/m3 |
Non-dispersive infrared spectrometry (NDIR) | PN-EN ISO 21258:2010 | |
| 81 | Automated Measuring Systems (AMS) | CO2 concentration Range (1 - 22) % |
Non-dispersive infrared spectrometry (NDIR) | ISO 12039:2019 | |
| 82 | General environment – noise from installations, equipment and industrial plants | A-weighted equivalent sound level, Range (25 - 135) dB |
Direct measurement method | Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023 item 1706) - excluding cl. F | |
| 83 | General environment – noise from installations, equipment and industrial plants | A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) | Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023 item 1706) - excluding cl. F | ||
Reference standards (29)
CEN/TS 17340:2020-09
ISO 12039:2019
ISO 15713:2006
PB/01/05:20.05.2024
PB/03/01:19.02.2024
PB/04/01:19.02.2024
PB/06/01:01.02.2025
PN-87/M-34129 Method A
PN-EN 12619:2013-05
PN-EN 13211:2006
PN-EN 13284-1:2018-02
PN-EN 13649:2005
PN-EN 14181:2015-02
PN-EN 14385:2025-05
PN-EN 14789:2017
PN-EN 14790:2017
PN-EN 14791:2017-04
PN-EN 14792:2017
PN-EN 15058:2017
PN-EN 1911:2011
PN-EN 1948-1:2006
PN-EN 1948-4+A1:2014-3
PN-EN ISO 21258:2010
PN-EN ISO 21877:2020-03
PN-EN-ISO 16911-1:2013-07
PN-ISO 10396:2001
PN-Z-04008-4:1999
PN-Z-04030-7:1994
Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023 item 1706) - excluding cl. F