🇵🇱 Paweł Lisowski EKSPERCKIE BIURO ZARZĄDZANIA PL
Environment
Paweł Lisowski EKSPERCKIE BIURO ZARZĄDZANIA is a laboratory accredited by PCA under number AB 752 (Ostrowiec Świętokrzyski, Poland). Its accreditation scope covers 51 test methods in the following areas: Environment. Test objects include: Workplace environment - air, Workplace environment - non-laser optical radiation, Workplace environment - electromagnetic field, General environment – noise from installations, equipment and indus…. Most frequently used techniques: Direct measurement method, Gravimetric method, Infrared spectrometry (FT-IR).
At a glance
- Accreditation number: PCA AB 752
- Methods in scope: 51
- Types of test objects: 18
- Techniques used: 17
- City: Ostrowiec Świętokrzyski, Poland
- Accreditation number
- AB 752
- Accreditation body
- PCA
- Address
- BEZPIECZEŃSTWEM PRACY, ul. Sandomierska 40, 27-400 Ostrowiec Świętokrzyski
- City
- Ostrowiec Świętokrzyski, Poland
What this laboratory tests (18)
- Workplace environment - air — 12 methods
- Workplace environment - non-laser optical radiation — 12 methods
- Workplace environment - electromagnetic field — 3 methods
- General environment – noise from installations, equipment and industrial plants — 2 methods
- Workplace environment - cold microclimate — 2 methods
- Workplace environment - hand-arm vibration — 2 methods
- Workplace environment - hot microclimate — 2 methods
- Workplace environment - moderate microclimate — 2 methods
- Workplace environment - noise — 2 methods
- Workplace environment - whole-body vibration — 2 methods
- Workplace environment − hearing protectors — 2 methods
- Workplace environment − indoor electric lighting — 2 methods
- Air filter — 1 method
- Cleanrooms and laminar flow cabinets — 1 method
- Compressed air — 1 method
- and 3 more
Analytical techniques used (17)
- Direct measurement method — 14 methods
- Gravimetric method — 2 methods
- Infrared spectrometry (FT-IR) — 2 methods
- Measurement method - measurement with a particle counter — 2 methods
- Measurement method - measurement with a particle counter; Measurement method - measurement with a linear photometer — 2 methods
- Direct measurement method (method A) — 1 method
- Direct measurement method (method M) — 1 method
- Direct measurement method (method O) — 1 method
- Direct measurement method (method X) — 1 method
- Direct measurement method (simplified) — 1 method
- Direct method - time measurement (min); Measurement method - measurement with a particle counter — 1 method
- Electrochemical method — 1 method
- Measurement method - indirect and direct — 1 method
- Measurement method – humidity measurement — 1 method
- Measurement method – pressure difference measurement — 1 method
- and 2 more
Laboratory sections (2)
- Paweł Lisowski Expert Occupational Safety Management Office, Working Environment Testing Section — 42 methods
- Paweł Lisowski Expert Occupational Safety Management Office, Cleanroom Testing Section — 9 methods
Laboratory locations
- Paweł Lisowski EKSPERCKIE BIURO ZARZĄDZANIA (main site) — ul. Sandomierska 40, 27-400 Ostrowiec Świętokrzyski
- Working Environment Testing Section — ul. Sandomierska 40, 27-400 Ostrowiec Świętokrzyski
- Cleanroom Testing Section — ul. Warszawska 31, 05-092 Łomianki
Certificate information
- Issue date
- 08.07.2026
- Issue no.
- 26
Accreditation scope — test methods (51)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Paweł Lisowski Expert Occupational Safety Management Office, Working Environment Testing Section | |||||
| 1 | Workplace environment - noise | A-weighted equivalent sound level, Maximum A-weighted sound level, Range (35 - 135) dB C-weighted peak sound pressure level, Range (40 - 138) dB |
Direct measurement method | PN-EN ISO 9612:2011 excluding the method covering strategy 3 - cl. 11 | PN-N-01307:1994 | |
| 2 | Workplace environment - noise | Noise exposure level referred to: an 8-hour daily working time the average weekly working time (calculated) |
PN-EN ISO 9612:2011 excluding the method covering strategy 3 - cl. 11 | PN-N-01307:1994 | ||
| 3 | Workplace environment − hearing protectors | Equivalent sound pressure level in octave frequency bands Range (63 - 8000) Hz Range (35 - 138) dB |
Direct measurement method | PN-EN 458:2016 | PN-EN ISO 4869-2:2018-12 | |
| 4 | Workplace environment − hearing protectors | A-weighted equivalent sound level under hearing protectors (calculated) | PN-EN 458:2016 | PN-EN ISO 4869-2:2018-12 | ||
| 5 | General environment – noise from installations, equipment and industrial plants | A-weighted equivalent sound pressure level Range (25 - 135) dB |
Direct measurement method | Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023 item 1706) - excluding cl. F | |
| 6 | General environment – noise from installations, equipment and industrial plants | A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) | Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023 item 1706) - excluding cl. F | ||
| 7 | Workplace environment - whole-body vibration | Frequency-weighted r.m.s. vibration acceleration Range (0,04 - 20) m/s2 |
Direct measurement method | PN-EN 14253+A1:2011 | |
| 8 | Workplace environment - whole-body vibration | Daily exposure, expressed as the 8-hour energy-equivalent frequency-weighted RMS vibration acceleration dominant among the vibration accelerations determined for the three directional components taking into account the appropriate coefficients (1,4awx, 1,4awy, awz), Exposure lasting 30 minutes and less, expressed as the frequency-weighted RMS vibration acceleration dominant among the vibration accelerations determined for the three directional components taking into account the appropriate coefficients (1.4awx, 1.4awy, awz) (calculated) | PN-EN 14253+A1:2011 | ||
| 9 | Workplace environment - hand-arm vibration | Frequency-weighted r.m.s. vibration acceleration Range (0,04 - 20) m/s2 |
Direct measurement method | PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/ A1:2015-11 | |
| 10 | Workplace environment - hand-arm vibration | Daily exposure, expressed as the energy-equivalent value for an 8-hour working day of the vector sum of the frequency-corrected r.m.s. vibration accelerations, determined for the three directional components (ahwx, ahwy, ahwz), Exposure lasting 30 minutes or less, expressed as the vector sum of the frequency-weighted r.m.s. vibration accelerations, determined for the three directional components (ahwx, ahwy, ahwz) (calculated) | PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/ A1:2015-11 | ||
| 11 | Workplace environment − indoor electric lighting | Illuminance Range (5,0 - 5000) lx |
Direct measurement method | EB3b-002 issue IV of 20.10.2024 | |
| 12 | Workplace environment − indoor electric lighting | Illuminance uniformity (calculated) | EB3b-002 issue IV of 20.10.2024 | ||
| 13 | Workplace environment - air | Sampling for the assessment of occupational exposure to: dust agents inhalable fraction respirable fraction organic substances, including inhalable fraction inorganic substances, including inhalable fraction respirable fraction thoracic fraction metals and their compounds, including inhalable fraction respirable fraction |
Personal dosimetry method | PN-Z-04008-7:2002+Az1:2004 | |
| 14 | Workplace environment - air | Exposure index (calculated) | PN-Z-04008-7:2002+Az1:2004 | ||
| 15 | Workplace environment - air | Concentration of harmful dust agents – inhalable fraction: dusts not classified according to toxicity titanium dioxide calcium sulfate (VI) (gypsum) synthetic graphite calcium magnesium carbonate (dolomite) apatites and phosphorites flour dusts natural graphite carbon black amorphous and synthetic silica portland cement wood dusts coal (hard, brown) kaolin organic dusts of animal and plant origin, except wood and flour dusts Range (0,14 - 20,4) mg/m3 |
Gravimetric method | PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08 | |
| 16 | Workplace environment - air | Concentration of harmful dust agents – respirable fraction: apatites and phosphorites natural graphite amorphous and synthetic silica portland cement coal (hard, brown) organic dusts of animal and plant origin, except wood and flour dusts Range (0,15 - 14,6) mg/m3 |
Gravimetric method | PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08 | |
| 17 | Workplace environment - air | Carbon monoxide concentration Range (2,3 - 117) mg/m3 |
Electrochemical method | EB3b-003 issue V of 26.04.2017 | |
| 18 | Workplace environment - air | Exposure indices (calculated) | EB3b-003 issue V of 26.04.2017 | ||
| 19 | Workplace environment - air | Crystalline silica (quartz, cristobalite) concentration – respirable fraction Range (0,008 - 0,5) mg/m3 |
Infrared spectrometry (FT-IR) | Principles and Methods of Assessing the Working Environment 2012, No. 4 (74), pp. 117–130 | |
| 20 | Workplace environment – air samples collected on filters | Crystalline silica content (quartz, cristobalite) – respirable fraction Range (5,0 - 400) μg in the sample |
Infrared spectrometry (FT-IR) | Principles and Methods of Assessing the Working Environment 2012, No. 4 (74), pp. 117–130 | |
| 21 | Workplace environment - hot microclimate | Air temperature Range (15 - 50) °C Natural wet bulb temperature Range (15 - 50) °C Black globe temperature Range (15 - 50) °C |
Direct measurement method | PN-EN ISO 7243:2018-01 | |
| 22 | Workplace environment - hot microclimate | WBGT index, WBGTeff index (calculated) | PN-EN ISO 7243:2018-01 | ||
| 23 | Workplace environment - moderate microclimate | Air temperature Range (10 - 30) °C Black globe temperature Range (10 - 35) °C Air humidity Range (20 - 85) % Air velocity Range (0,15 - 1,0) m/s |
Direct measurement method | PN-EN ISO 7730:2006+Ap2:2016-04 | |
| 24 | Workplace environment - moderate microclimate | PMV index, PPD index (calculated) | PN-EN ISO 7730:2006+Ap2:2016-04 | ||
| 25 | Workplace environment - cold microclimate | Air temperature Range (-30 - 10) °C Black globe temperature Range (-30 - 10) °C Air humidity Range (20 - 90) % Air velocity Range (0,15 - 2,0) m/s |
Direct measurement method | PN-EN ISO 11079:2008 | |
| 26 | Workplace environment - cold microclimate | IREQmin index, IREQneutral index, twc index (calculated) | PN-EN ISO 11079:2008 | ||
| 27 | Workplace environment - electromagnetic field | Electric field strength in the frequency range 10 Hz - 400 kHz Range (20 V/m - 19 kV/m), 100 kHz - 40 MHz Range (0,4 - 253) V/m |
Direct measurement method | PN-T-06580-3:2002 excluding cl. 2.1.4.2 Method adapted to the regulated area | |
| 28 | Workplace environment - electromagnetic field | Magnetic field strength in the frequency range 10 Hz - 400 kHz Range (0,5 - 800) A/m, 300 kHz - 40 MHz Range (0,010 - 16,0) A/m |
Direct measurement method | PN-T-06580-3:2002 excluding cl. 2.1.4.2 Method adapted to the regulated area | |
| 29 | Workplace environment - electromagnetic field | Magnetic flux density in the frequency range 0 Hz: Range (0,1 - 1000) mT |
Direct measurement method | PN-T-06580-3:2002 excluding cl. 2.1.4.2 Method adapted to the regulated area | |
| 30 | Workplace environment - electromagnetic field in the workspace from magnetotherapy devices | Magnetic field strength in the frequency range from 10 Hz to 1 kHz Range (1 - 800) A/m Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 consolidated text: (Journal of Laws 2018, item 331) |
Direct measurement method (simplified) | Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 151–180 | |
| 31 | Workplace environment - non-laser optical radiation | Effective irradiance UV in the spectral range (180 - 400) nm Range (10-6 - 39,9) W/m2 |
Direct measurement method (method A) | PN-EN 14255-1:2010 | |
| 32 | Workplace environment - non-laser optical radiation | Effective radiant exposure for UV in the spectral range (180 - 400) nm (calculated) | PN-EN 14255-1:2010 | ||
| 33 | Workplace environment - non-laser optical radiation | Irradiance for UVA in the spectral range (315 - 400) nm Range (10-3 - 3990) W/m2 |
Direct measurement method (method M) | PN-EN 14255-1:2010 | |
| 34 | Workplace environment - non-laser optical radiation | Radiant exposure for UVA in the spectral range (315 - 400) nm (calculated) | PN-EN 14255-1:2010 | ||
| 35 | Workplace environment - non-laser optical radiation | Effective irradiance VIS in the spectral range (300 - 700) nm Range (10-6 - 399) W/m2 |
Direct measurement method (method O) | PN-EN 14255-2:2010 | |
| 36 | Workplace environment - non-laser optical radiation | Effective radiance VIS in the spectral range (300 - 700) nm (calculated) | PN-EN 14255-2:2010 | ||
| 37 | Workplace environment - non-laser optical radiation | Irradiance of VIS, IRA and IRB in the spectral range (380 - 3000) nm Range (30 - 3999) W/m2 |
Direct measurement method (method X) | PN-EN 14255-2:2010 | |
| 38 | Workplace environment - non-laser optical radiation | Radiant exposure of VIS, IRA and IRB in the spectral range (380 - 3000) nm (calculated) | PN-EN 14255-2:2010 | ||
| 39 | Workplace environment - non-laser optical radiation | Effective irradiance VIS and IRA in the spectral range (380 - 1 400) nm Range (10-6 - 3990) W/m2 |
Direct measurement method | PN-T 05687: 2002 cl. 2.5.4 | |
| 40 | Workplace environment - non-laser optical radiation | Effective radiance VIS and IRA in the spectral range (380 - 1 400) nm (calculated) | PN-T 05687: 2002 cl. 2.5.4 | ||
| 41 | Workplace environment - non-laser optical radiation | Effective irradiance IRA in the spectral range (780 - 1 400) nm Range (10-3 - 3990) W/m2 |
Direct measurement method | PN-T 05687: 2002 cl. 2.5.4 | |
| 42 | Workplace environment - non-laser optical radiation | Effective radiance IRA in the spectral range (1400 - 3000) nm (calculated) | PN-T 05687: 2002 cl. 2.5.4 | ||
| Paweł Lisowski Expert Occupational Safety Management Office, Cleanroom Testing Section | |||||
| 43 | Workplace environment - air | Air cleanliness: Particle number concentration for diameters: (0,1; 0,3; 0,5; 1,0; 3,0; 5,0) μm Range (1 - 9.999.999) particles/ft3 or Range (35 - 349.999.965) particles/m3 |
Measurement method - measurement with a particle counter | PN-EN ISO 14644-1:2016-03 | |
| 44 | Workplace environment - air | Recovery time to the initial air cleanliness: Particle number concentration for diameters: (0,1; 0,3; 0,5; 1,0; 3,0; 5,0) μm Range (1 - 9.999.999) particles/ft3 or Range (35 - 349.999.965) particles/m3 |
Direct method - time measurement (min); Measurement method - measurement with a particle counter | PN-EN ISO 14644-3:2020 cl. 4.2.4 and Annex B.4 | |
| 45 | Workplace environment - air | Pressure difference: Range (-2500 - +2500) Pa |
Measurement method – pressure difference measurement | PN-EN ISO 14644-3:2020 cl. 4.2.1 and Annex B.1 | |
| 46 | Workplace environment - air | Temperature Range (-40 - +70) °C |
Measurement method – temperature measurement | PN-EN ISO 14644-3:2020 cl. 4.2.5 and Annex B.5 | |
| 47 | Workplace environment - air | Relative humidity Range (0 - 90) % |
Measurement method – humidity measurement | PN-EN ISO 14644-3:2020 cl. 4.2.6 and Annex B.6 | |
| 48 | Cleanrooms and laminar flow cabinets | Penetration Number content of particles with diameters: (0,1; 0,3; 0,5; 1,0; 3,0; 5,0) μm Range (diluter 1:100): Range (1 - 9.999.999) particles/ft3 or Range (35 - 349.999.965) particles/m3 particle mass concentration Range (0,0003 - 100) g/l |
Measurement method - measurement with a particle counter; Measurement method - measurement with a linear photometer | PN-EN ISO 14644-3:2020 cl. 4.2.8 and Annex B.8 | |
| 49 | Air filter | Integrity and tightness of the filter mounting: Particle number content for diameters: (0,1; 0,3; 0,5; 1,0; 3,0; 5,0) μm Range (diluter 1:100): Range (1 - 9.999.999) particles/ft3 or Range (35 - 349.999.965) particles/m3 Particle mass concentration Range (0,0003 - 100) g/l |
Measurement method - measurement with a particle counter; Measurement method - measurement with a linear photometer | PN-EN ISO 14644-3:2020 cl. 4.2.7 and Annex B.7 | PN-EN 1822-1:2019-05 cl. 5 and 6 | |
| 50 | Compressed air | Cleanliness: - number concentration of particles with diameters: (0,1; 0,3; 0,5; 1,0; 3,0; 5,0) μm Range (diluter 1:100) Range (1 - 9.999.999) particles/ft3 or Range (35 - 349.999.965) particles/m3 |
Measurement method - measurement with a particle counter | EB3b-001 issue VII of 18.07.2022 | |
| 51 | Ventilation | Air velocity: Range (0,2 - 40) m/s Air volume flow rate: Range (50 - 2000) m3/h |
Measurement method - indirect and direct | PN-EN ISO 14644-3:2020 cl. 4.2.2 and Annex B.2 | |
Reference standards (35)
EB3b-001 issue VII of 18.07.2022
EB3b-002 issue IV of 20.10.2024
EB3b-003 issue V of 26.04.2017
PN-EN 14253+A1:2011
PN-EN 14255-1:2010
PN-EN 14255-2:2010
PN-EN 1822-1:2019-05 cl. 5 and 6
PN-EN 458:2016
PN-EN ISO 11079:2008
PN-EN ISO 14644-1:2016-03
PN-EN ISO 14644-3:2020 cl. 4.2.1 and Annex B.1
PN-EN ISO 14644-3:2020 cl. 4.2.2 and Annex B.2
PN-EN ISO 14644-3:2020 cl. 4.2.4 and Annex B.4
PN-EN ISO 14644-3:2020 cl. 4.2.5 and Annex B.5
PN-EN ISO 14644-3:2020 cl. 4.2.6 and Annex B.6
PN-EN ISO 14644-3:2020 cl. 4.2.7 and Annex B.7
PN-EN ISO 14644-3:2020 cl. 4.2.8 and Annex B.8
PN-EN ISO 4869-2:2018-12
PN-EN ISO 5349-1:2004
PN-EN ISO 5349-2:2004
PN-EN ISO 5349-2:2004/ A1:2015-11
PN-EN ISO 7243:2018-01
PN-EN ISO 7730:2006+Ap2:2016-04
PN-EN ISO 9612:2011 excluding the method covering strategy 3 - cl. 11
PN-N-01307:1994
PN-T 05687: 2002 cl. 2.5.4
PN-T-06580-3:2002 excluding cl. 2.1.4.2 Method adapted to the regulated area
PN-Z-04008-7:2002+Az1:2004
PN-Z-04507:2022-05
PN-Z-04507:2022-05/Ap1:2022-08
PN-Z-04508:2022-05
PN-Z-04508:2022-05/Ap1:2022-08
Principles and Methods of Assessing the Working Environment 2012, No. 4 (74), pp. 117–130
Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 151–180
Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023 item 1706) - excluding cl. F