🇵🇱 Eurofins SEPO Sp. z o. o. PL
EnvironmentMaterials & polymers
Eurofins SEPO Sp. z o. o. is a laboratory accredited by PCA under number AB 746 (Knurów, Poland). Its accreditation scope covers 290 test methods in the following areas: Environment, Materials & polymers. Test objects include: Workplace environment – air – air samples collected into sorbent tubes, Waste gases, Waste gases – waste gas samples collected into absorbing solution, Automated Measuring Systems (AMS). Most frequently used techniques: Gas chromatography with flame ionization detection (GC-FID), Spectrophotometric method, Direct measurement method.
At a glance
- Accreditation number: PCA AB 746
- Methods in scope: 290
- Types of test objects: 41
- Techniques used: 40
- City: Knurów, Poland
- Accreditation number
- AB 746
- Accreditation body
- PCA
- Address
- ul. Dworcowa 47, 44-190 Knurów
- City
- Knurów, Poland
What this laboratory tests (41)
- Workplace environment – air – air samples collected into sorbent tubes — 53 methods
- Waste gases — 37 methods
- Waste gases – waste gas samples collected into absorbing solution — 33 methods
- Automated Measuring Systems (AMS) — 21 methods
- Workplace environment – non-laser optical radiation — 14 methods
- Waste gases – waste gas samples collected into sorbent tubes — 13 methods
- Workplace environment – air — 12 methods
- Workplace environment – air – air samples collected into absorbing solution — 12 methods
- Waste gas cleaning installations — 10 methods
- Waste gases - waste gas samples collected into absorbing solution — 9 methods
- Waste gases - waste gas samples collected into absorbing solution - waste gas samples collected on a filter — 8 methods
- Workplace environment – air – air samples collected on filters — 8 methods
- Waste gases – waste gas samples collected on a filter — 6 methods
- Workplace environment – emergency lighting — 5 methods
- General environment – ambient air — 3 methods
- and 26 more
Analytical techniques used (40)
- Gas chromatography with flame ionization detection (GC-FID) — 61 methods
- Spectrophotometric method — 23 methods
- Direct measurement method — 22 methods
- Gravimetric method — 11 methods
- High-performance liquid chromatography with fluorescence detection (HPLC-FLD) — 7 methods
- Chemiluminescence method — 5 methods
- Potentiometric method — 4 methods
- Thoron method — 4 methods
- Continuous flame ionization detection method (FID) — 3 methods
- Method (NDIR) — 3 methods
- NDIR method — 3 methods
- Condensation-adsorption method — 2 methods
- Electrochemical method — 2 methods
- Filtration and condensation method — 2 methods
- Non-dispersive infrared spectrometry (NDIR) — 2 methods
- and 25 more
Laboratory locations
- Eurofins SEPO Sp. z o. o. (main site) — ul. Dworcowa 47, 44-190 Knurów
- Measurement and Analytical Department — ul. Dworcowa 47, 44-190 Knurów
Certificate information
- Issue date
- 22.07.2026
- Issue no.
- 38
Accreditation scope — test methods (290)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Measurement and Analytical Department | |||||
| 1 | Workplace environment – air | Sampling for the assessment of occupational exposure to: dust agents inhalable fraction respirable fraction organic substances, including inhalable fraction inorganic substances, including inhalable fraction respirable fraction metals and their compounds, including inhalable fraction respirable fraction |
Personal dosimetry method; Stationary method | PN-Z-04008-7:2002+Az1:2004 | |
| 2 | Workplace environment – air | Sampling for the assessment of occupational exposure to: inorganic substances, including thoracic fraction asbestos – respirable fibres man-made mineral fibres excluding refractory ceramic fibres – respirable fibres silicon carbide fibrous – respirable fibres refractory ceramic fibres refractory ceramic fibres mixed with other man-made mineral fibres |
Personal dosimetry method | PN-Z-04008-7:2002+Az1:2004 | |
| 3 | Workplace environment – air | Exposure index (calculated) | PN-Z-04008-7:2002+Az1:2004 | ||
| 4 | Workplace environment – air | Concentration of harmful dust agents - inhalable fraction: Apatites and phosphorites Portland cement Titanium dioxide Natural graphite Synthetic graphite Kaolin Amorphous and synthetic silica Wood dusts Flour dusts Dusts not classified according to toxicity Organic dusts of animal and plant origin, excluding wood and flour dusts Calcium sulfate (VI) (gypsum) Carbon black Talc Coal (hard, brown) Calcium magnesium carbonate (dolomite) Silicon carbide, non-fibrous Silicon carbide, fibrous Man-made mineral fibres excluding refractory ceramic fibres Range (0,05 – 20,0) mg/m3 |
Gravimetric method | PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08 | |
| 5 | Workplace environment – air | Concentration of harmful dust agents - respirable fraction: Apatites and phosphorites Portland cement Natural graphite Amorphous and synthetic silica Organic dusts of animal and plant origin, excluding wood and flour dusts Diesel engine exhaust Talc Coal (hard, brown) Range (0,05 – 7,0) mg/m3 |
Gravimetric method | PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08 | |
| 6 | Workplace environment – air | Concentration of dust collected with a CIP-10 dust sampler – inhalable fraction Range (0,11 – 69) mg/m3 |
Gravimetric method | PN-Z-04507:2022-05 | |
| 7 | Workplace environment – air | Concentration of dust collected with a CIP-10 dust sampler – respirable fraction Range (0,11 – 69) mg/m3 |
Gravimetric method | PN-Z-04508:2022-05 | |
| 8 | Workplace environment – air | Sampling of highly refined mineral oils – excluding metalworking fluids – inhalable fraction | Personal dosimetry method | PN-Z-04108-5:2006 | |
| 9 | Workplace environment – air | Exposure index (calculated) | PN-Z-04108-5:2006 | ||
| 10 | Workplace environment – air | Carbon monoxide concentration CO (3,5 - 234) mg/m3 Range (3,0 - 201) ppm |
Electrochemical method | PB-07/W7-10.09.2021 | |
| 11 | Workplace environment – air | Carbon dioxide concentration CO2 (732 – 55836) mg/m3 |
Infrared spectrometry method | PB-07/W7-10.09.2021 | |
| 12 | Workplace environment – air | Exposure indices (calculated) | PB-07/W7-10.09.2021 | ||
| 13 | Workplace environment – air – air samples collected into absorbing solution | Concentration / content of nitrogen monoxide, nitrogen dioxide NO (0,144 – 22,2) mg/m3 Range (0,115 – 17,8) ppm Range (0,00065 – 0,100) mg in the sample NO2 (0,044 – 4,44) mg/m3 NO2 (0,023 – 2,32) ppm NO2 (0,00020 – 0,020) mg in the sample |
Spectrophotometric method | PN-Z-04009-11:2008 | |
| 14 | Workplace environment – air – air samples collected into absorbing solution | Concentration / content of sulphur dioxide Range (0,10 – 6,40) mg/m3 Range (0,038 – 2,40) ppm Range (0,0010 – 0,0640) mg in the sample |
Spectrophotometric method | PN-Z-04015-12:1996+Ap1:2001 | |
| 15 | Workplace environment – air – air samples collected into absorbing solution | Concentration / content of nitric (V) acid Range (0,28 – 2,44) mg/m3 Range (0,000274 – 0,0274) mg in the sample |
Spectrophotometric method | PN-Z-04009-11:2008 | PN-Z-04073-1:2014-08 | |
| 16 | Workplace environment – air – air samples collected into absorbing solution | Concentration / content of tetraphosphorus decaoxide Range (0,10 – 2,86) mg/m3 Range (0,00070 – 0,020) mg in the sample |
Spectrophotometric method | PN-Z-04009-11:2008 | PN-Z-04073-1:2014-08 | |
| 17 | Workplace environment – air – air samples collected into absorbing solution | Concentration / content of phosphoric (V) acid Range (0,065 – 2,00) mg/m3 Range (0,000455 – 0,0140) mg in the sample |
Spectrophotometric method | PN-Z-04073-1:2014-08 | |
| 18 | Workplace environment – air – air samples collected into absorbing solution | Chlorine concentration / content Range (0,067 – 1,52) mg/m3 Range (0,0010 – 0,0228) mg in the sample |
Spectrophotometric method | PN-75/Z-04037.03 | |
| 19 | Workplace environment – air – air samples collected into absorbing solution | Hydrogen sulphide concentration / content Range (0,70 – 20) mg/m3 Range (0,0070 – 0,20) mg in the sample |
Spectrophotometric method | PN-Z-04015-13:1996 | |
| 20 | Workplace environment – air – air samples collected into absorbing solution | Ammonia concentration / content Range (0,75 – 30) mg/m3 Range (0,00750 – 0,30) mg in the sample |
Spectrophotometric method | PN-71/Z-04041 | |
| 21 | Workplace environment – air – air samples collected into absorbing solution | Concentration / content of fluorides expressed as F - Range (0,06 – 60) mg/m3 Range (0,0030 – 3,0) mg in the sample |
Potentiometric method | PB-61/CzA/W6-24.01.2018 | PB-27/W8-29.03.2021 | |
| 22 | Workplace environment – air – air samples collected into absorbing solution | Concentration / content of fluorine, hydrogen fluoride (calculated) | PB-61/CzA/W6-24.01.2018 | PB-27/W8-29.03.2021 | ||
| 23 | Workplace environment – air – air samples collected into absorbing solution | Concentration / content of N,N dimethylaniline (dimethylaniline, N-dimethylaniline) Range (1,20 – 80,0) mg/m3 Range (0,0120 – 0,80) mg in the sample |
Spectrophotometric method | PN-81/Z-04031.02 | |
| 24 | Workplace environment – air – air samples collected into absorbing solution | Concentration / content of ozone Range (0,0150 – 0,300) mg/m3 Range (0,00060 – 0,0120) mg in the sample |
Spectrophotometric method | PN-Z-04007-2:1994 | |
| 25 | Workplace environment – air – air samples collected on filters | Concentration / content of isocyanates: 2,4-TDI (toluene-2,4-diyl diisocyanate, 2,4-diisocyanatotoluene) Range (0,00070 – 0,20) mg/m3 Range (0,10 – 50) μg in the sample 2,6-TDI ( toluene-2,6-diyl diisocyanate, toluene 2,6-diisocyanate) Range (0,00070 – 0,20) mg/m3 Range (0,10 – 50) μg in the sample MDI (methylenebis (phenyl isocyanate), 4,4'-methylenebis(phenyl isocyanate) Range (0,00070 – 0,20) mg/m3 Range (0,10 – 50) μg in the sample HDI (hexane-1,6-diyl diisocyanate, hexamethylene 1,6-diisocyanate) Range (0,00070 – 0,20) mg/m3 Range (0,10 – 50) μg in the sample |
High-performance liquid chromatography with fluorescence detection (HPLC-FLD) | PB-61/CzD/W2-01.04.2015 * | PB-102/W2-18.03.2015 * | |
| 26 | Workplace environment – air – air samples collected on filters | Concentration / content of benzo(a)pyrene Range (0,080 – 6,94) μg/m3 Range (0,050 – 5,0) μg in the sample |
High-performance liquid chromatography with fluorescence detection (HPLC-FLD) | PN-Z-04240-2:1999 * | |
| 27 | Workplace environment – air – air samples collected on filters | Concentration / content of dibenzo(a,h)anthracene Range (0,080 – 13,89) μg/m3 Range (0,050 – 10) μg in the sample |
High-performance liquid chromatography with fluorescence detection (HPLC-FLD) | PN-Z-04240-4:1999 * | |
| 28 | Workplace environment – air – air samples collected on filters and into sorbent tubes | Concentration / content of PAH dibenzo(a,h)anthracene benzo(a)pyrene benzo(a)anthracene benzo(b)fluoranthene benzo(k)fluoranthene indeno(1,2,3-c,d)pyrene anthracene benzo(g,h,i)perylene chrysene Range (0,09 – 59) μg/m3 Range (0,01 – 5,0) μg in the sample Exposure index as the sum of the products of concentrations and carcinogenicity factors of 9 carcinogenic PAHs (calculated) |
High-performance liquid chromatography with fluorescence detection (HPLC-FLD) | PN-Z-04240-5:2006 * | |
| 29 | Workplace environment – air – air samples collected on filters | Concentration / content of crystalline silica (quartz and cristobalite) respirable fraction Range (0,0038 – 0,58) mg/m3 Range (0,006 – 0,40) mg in the sample Fourier (FT-IR) |
Infrared spectrometry with transform | Principles and Methods of Assessing the Working Environment 2012, No. 4 (74), pp. 117–130 | |
| 30 | Workplace environment – air – air samples collected on filters | Concentration / content of highly refined mineral oils excluding metalworking fluids – inhalable fraction Range (0,208 – 20,83) mg/ m3 Range (0,2 – 15) mg in the sample |
Infrared spectrometry (FT-IR) | PN-Z-04108-5:2006 | |
| 31 | Workplace environment – air – air samples collected on filters | Concentration / content of ammonium chloride vapours and inhalable fraction Range (0,13 – 40) mg/m3 Range (0,50 – 15) mg in the sample |
Spectrophotometric method | PN-Z-04265:2000 | |
| 32 | Workplace environment – air – air samples collected on filters | Hydrogen chloride concentration / content Range (0,50 – 10,0) mg/m3 Range (0,360 – 7,20) mg in the sample |
Turbidimetric method | PN-Z-04450:2014-08 | |
| 33 | Workplace environment – air – air samples collected into sorbent tubes | Concentration / content of acetone Range (31,2 – 3600) mg/m3 Range (0,50 – 10) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-89/Z-04023.02 IR-230/W5-08.03.2019 | |
| 34 | Workplace environment – air – air samples collected into sorbent tubes | Concentration / content of toluene Range (0,083 – 417) mg/m3 Range (0,0010 – 5,0) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-89/Z-04023.02 IR-230/W5-08.03.2019 | |
| 35 | Workplace environment – air – air samples collected into sorbent tubes | Concentration / content of ethanol (ethyl alcohol) Range (62,5 – 3800) mg/m3 Range (1,0 – 10) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-89/Z-04023.02 IR-230/W5-08.03.2019 | |
| 36 | Workplace environment – air – air samples collected into sorbent tubes | Concentration / content of xylene Range (0,062 – 400) mg/m3 Range (0,0010 – 5,0) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-89/Z-04023.02 IR-230/W5-08.03.2019 | |
| 37 | Workplace environment – air – air samples collected into sorbent tubes | Concentration / content of butan-1-ol (n-butyl alcohol) Range (0,062 – 300) mg/m3 Range (0,0010 – 5,0) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-89/Z-04023.02 IR-230/W5-08.03.2019 | |
| 38 | Workplace environment – air – air samples collected into sorbent tubes | Concentration / content of ethyl acetate Range (31,2 – 2936) mg/m3 Range (8,5 – 801) ppm Range (0,50 – 5,0) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-89/Z-04023.02 IR-230/W5-08.03.2019 | |
| 39 | Workplace environment – air – air samples collected into sorbent tubes | Concentration / content of n-butyl acetate Range (0,062 – 1440) mg/m3 Range (0,0010 – 10) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-89/Z-04023.02 IR-230/W5-08.03.2019 | |
| 40 | Workplace environment – air – air samples collected into sorbent tubes | Concentration / content of 2-butoxyethanol (butoxyethyl alcohol) Range (0,62 – 400) mg/m3 Range (0,010 – 5,0) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-89/Z-04023.02 IR-230/W5-08.03.2019 | |
| 41 | Workplace environment – air – air samples collected into sorbent tubes | Concentration / content of 2-methylpropan-1-ol (isobutyl alcohol) Range (0,83 – 417) mg/m3 Range (0,010 – 5,0) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-89/Z-04023.02 IR-230/W5-08.03.2019 | |
| 42 | Workplace environment – air – air samples collected into sorbent tubes | Benzene concentration / content Range (0,062 – 3,2) mg/m3 Range (0,019 – 1,0) ppm Range (0,0010 – 2,0) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04016-10:2005 | |
| 43 | Workplace environment – air – air samples collected into sorbent tubes | Concentration / content of ethylbenzene Range (0,062 – 800) mg/m3 Range (0,0010 – 10) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-79/Z-04081.01 | |
| 44 | Workplace environment – air – air samples collected into sorbent tubes | Concentration / content of cumene (isopropylbenzene) Range (0,62 – 500) mg/m3 Range (0,010 – 5,0) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04016-6:1998 | |
| 45 | Workplace environment – air – air samples collected into sorbent tubes | Concentration / content of trimethylbenzene Range (0,62 – 340) mg/m3 Range (0,010 – 5,0) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04016-4:1998 | |
| 46 | Workplace environment – air – air samples collected into sorbent tubes | Concentration / content of butan -2-one (methyl ethyl ketone) Range (6,2 – 1800) mg/m3 Range (0,1 – 15) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04449:2014-06 | |
| 47 | Workplace environment – air – air samples collected into sorbent tubes | Concentration / content of 1-methoxypropan-2-ol Range (6,2 – 720) mg/m3 Range (0,10 – 10) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04354:2005 | |
| 48 | Workplace environment – air – air samples collected into sorbent tubes | Concentration / content of propan-2-ol (isopropyl alcohol) Range (31,2 – 2400) mg/m3 Range (0,50 – 10) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04224-02:1992 | |
| 49 | Workplace environment – air – air samples collected into sorbent tubes | Concentration / content of propan-1-ol (propyl alcohol) Range (6,2 – 1200) mg/m3 Range (0,10 – 10) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04224-3:2003 | |
| 50 | Workplace environment – air – air samples collected into sorbent tubes | Styrene concentration / content Range (0,62 – 200) mg/m3 Range (0,010 – 5,0) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-86/Z-04152.02 | |
| 51 | Workplace environment – air – air samples collected into sorbent tubes | Concentration / content of 4-methylpentan-2-one (methyl isobutyl ketone, hexone) Range (0,62 – 400) mg/m3 Range (0,010 – 5,0) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-86/Z-04165.02 | |
| 52 | Workplace environment – air – air samples collected into sorbent tubes | Concentration / content of 4-hydroxy-4-methylpentan-2-one (diacetone alcohol) Range (6,2 – 480) mg/m3 Range (0,10 – 10) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04368:2008 | |
| 53 | Workplace environment – air – air samples collected into sorbent tubes | Concentration / content of extraction naphtha Range (6,2 – 3000) mg/m3 Range (0,1 – 20) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-81/Z-04134.02 | |
| 54 | Workplace environment – air – air samples collected into sorbent tubes | Concentration / content of white spirit Range (6,2 – 1800) mg/m3 Range (0,10 – 10) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-81/Z-04134.03 | |
| 55 | Workplace environment – air – air samples collected into sorbent tubes | Concentration / content of trichloroethene (trichloroethylene) Range (0,062 – 200) mg/m3 Range (0,0010 – 2,0) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-78/Z-04047.02 | |
| 56 | Workplace environment – air – air samples collected into sorbent tubes | Pentane concentration / content Range (125 – 6000) mg/m3 Range (2,0 – 10) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04318:2005 | |
| 57 | Workplace environment – air – air samples collected into sorbent tubes | Concentration / content of hexane Range (0,062 – 144) mg/m3 Range (0,0010 – 5) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04136-3:2003 | |
| 58 | Workplace environment – air – air samples collected into sorbent tubes | Concentration / content of heptane Range (62,5 – 4000) mg/m3 Range (1,0 – 10) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-84/Z-04138.02 | |
| 59 | Workplace environment – air – air samples collected into sorbent tubes | Concentration / content of octane Range (31,2 – 3600) mg/m3 Range (0,50 – 10) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-86/Z-04166.02 | |
| 60 | Workplace environment – air – air samples collected into sorbent tubes | Concentration / content of cyclohexane Range (6,2 – 2000) mg/m3 Range (0,10 – 10) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-86/Z-04151.02 | |
| 61 | Workplace environment – air – air samples collected into sorbent tubes | Concentration / content of methylcyclohexane Range (62,5 – 6000) mg/m3 Range (1,0 – 10) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04137-02:1984 | |
| 62 | Workplace environment – air – air samples collected into sorbent tubes | Concentration / content of cyclohexanone Range (0,062 – 160) mg/m3 Range (0,0010 – 2,0) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04447:2014-06 | |
| 63 | Workplace environment – air – air samples collected into sorbent tubes | Concentration / content of cyclohexanol Range (0,312 – 20) mg/m3 Range (0,005 – 2,0) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04448:2014-06 | |
| 64 | Workplace environment – air – air samples collected into sorbent tubes | Concentration / content of chloroform Range (0,312 – 16) mg/m3 Range (0,005 – 2,0) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-88/Z-04187.02 | |
| 65 | Workplace environment – air – air samples collected into sorbent tubes | Concentration / content of dichloromethane Range (0,62 – 707) mg/m3 Range (0,18 – 200) ppm Range (0,010 – 5,0) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-77/Z-04110.01 | |
| 66 | Workplace environment – air – air samples collected into sorbent tubes | Concentration / content of tetrachloroethene (tetrachloroethylene) Range (0,062 – 340) mg/m3 Range (0,0090 – 49) ppm Range (0,0010 – 5,0) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-78/Z-04118.01 | |
| 67 | Workplace environment – air – air samples collected into sorbent tubes | Concentration / content of carbon tetrachloride Range (0,312 – 64) mg/m3 Range (0,049 – 10) ppm Range (0,0050 – 2,0) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-77/Z-04074.02 | |
| 68 | Workplace environment – air – air samples collected into sorbent tubes | Concentration / content of diethyl ether Range (6,2 – 1200) mg/m3 Range (0,10 – 10) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-86/Z-04158.02 | |
| 69 | Workplace environment – air – air samples collected into sorbent tubes | Concentration / content of butan-2-ol (sec-butyl alcohol) Range (6,2 – 900) mg/m3 Range (0,10 – 10) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04155-4:1996 | |
| 70 | Workplace environment – air – air samples collected into sorbent tubes | Concentration / content of (2-methoxymethylethoxy) propanol Range (6,2 – 960) mg/m3 Range (0,10 – 10) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04346:2006 | |
| 71 | Workplace environment – air – air samples collected into sorbent tubes | Concentration / content of diethylbenzene Range (0,062 – 800) mg/m3 Range (0,0010 – 5,0) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04016-8:1999 | |
| 72 | Workplace environment – air – air samples collected into sorbent tubes | Concentration / content of 2-furylmethanol (furfuryl alcohol) Range (0,062 – 120) mg/m3 Range (0,010 – 2,0) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04214-02:1990 | |
| 73 | Workplace environment – air – air samples collected into sorbent tubes | Concentration / content of 2-butoxyethyl acetate Range (0,062 – 600) mg/m3 Range (0,0010 – 5,0) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04304:2003 | |
| 74 | Workplace environment – air – air samples collected into sorbent tubes | Concentration / content of sec-butyl acetate Range (6,2 – 1440) mg/m3 Range (0,1 – 10) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04119-2:1998 | |
| 75 | Workplace environment – air – air samples collected into sorbent tubes | Concentration / content of tert-butyl acetate Range (31,2 – 1800) mg/m3 Range (0,50 – 10) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04119-3:1998 | |
| 76 | Workplace environment – air – air samples collected into sorbent tubes | Concentration / content of 2-methoxy-1-methylethyl acetate Range (6,2 – 1040) mg/m3 Range (0,10 – 10) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04119-10:2008/Ap1:2011 | |
| 77 | Workplace environment – air – air samples collected into sorbent tubes | Concentration / content of isobutyl acetate Range (0,62 – 1440) mg/m3 Range (0,010 – 10) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04119-11:2008/Ap1:2011 | |
| 78 | Workplace environment – air – air samples collected into sorbent tubes | Concentration / content of carbon disulphide Range (0,62 – 25) mg/m3 Range (0,010 – 2,0) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04015-15:1999 | |
| 79 | Workplace environment – air – air samples collected into sorbent tubes | Concentration / content of methanol Range (0,156 – 600) mg/m3 Range (0,0050 – 10) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PB-61/CzC/W5-24.01.2018 | PB-03/CzG/W8-22.01.2018 | |
| 80 | Workplace environment – air – air samples collected into sorbent tubes | Phenol concentration / content Range (0,312 – 32) mg/m3 Range (0,0050 – 1,0) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04159-10:1989 | |
| 81 | Workplace environment – air – air samples collected into sorbent tubes | Concentration / content of kerosene Range (0,61 – 600) mg/m3 Range (0,010 – 5,0) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04227-02:1992 | |
| 82 | Workplace environment – air – air samples collected into sorbent tubes | Formaldehyde concentration / content Range (0,0147 – 1,48) mg/m3 Range (0,00047 – 0,050) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PB-61/CzC/W5-24.01.2018 | PB-03/CzG/W8-22.01.2018 | |
| 83 | Workplace environment – air – air samples collected into sorbent tubes | Concentration / content of acetic acid Range (0,312 – 100) mg/m3 Range (0,125 – 40) ppm Range (0,0050 – 2,0) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04323:2004 | |
| 84 | Workplace environment – air – air samples collected into sorbent tubes | Naphthalene concentration / content Range (0,62 – 100) mg/m3 Range (0,010 – 1,0) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04098-3:2005 | |
| 85 | Workplace environment – air – air samples collected into sorbent tubes | Concentration / content of nicotine Range (0,04 – 1,0) mg/m3 Range (0,00048 – 0,016) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | Principles and Methods of Assessing the Working Environment 2003, No. 4 (38), pp. 149–155 | |
| 86 | Workplace environment – air – air samples collected on filters | Concentration / content of glycerol – inhalable fraction Range (0,80 – 20) mg/m3 Range (0,14 – 3,6) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04374:2009 | |
| 87 | Workplace environment – air – air samples collected on a filter and into sorbent tubes | Concentration / content of propane-1,2-diol – vapours and inhalable fraction Range (8,0 – 200) mg/m3 Range (1,4 – 36) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | Principles and Methods of Assessing the Working Environment 2017, No. 2 (92), pp. 173–188 | |
| 88 | General environment – ambient air | Sampling of suspended particulate matter, PM 2,5 and PM 10 | PN-EN 12341:2024-01 | ||
| 89 | General environment – ambient air | Concentration of suspended particulate matter PM 2,5 Range (1,0-300,0) μg/m3 |
Gravimetric method | PN-EN 12341:2024-01 | |
| 90 | General environment – ambient air | Concentration of suspended particulate matter PM 10 Range (1,0-300,0) μg/m3 |
Gravimetric method | PN-EN 12341:2024-01 | |
| 91 | Machinery and equipment – noise | A-weighted equivalent sound pressure level Range (40,0 – 137,0) dB |
Direct measurement method | PN-EN ISO 3746:2011+Ap1:2017-09 | |
| 92 | Machinery and equipment – noise | Sound power level (calculated) | PN-EN ISO 3746:2011+Ap1:2017-09 | ||
| 93 | General environment – noise from high-voltage power lines | A-weighted equivalent sound pressure level Range (25,0 – 136,0) dB |
Direct measurement method | PN-N-01339:2000 Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (Journal of Laws of 2023, item 1706) | |
| 94 | General environment – noise from roads, railway and tramway lines | A-weighted equivalent sound level A-weighted sound exposure level Range (28,0 – 136,0) dB |
Direct measurement method | Annex 3 to the Regulation of the Minister of the Environment of 16.06.2011 (Journal of Laws No. 140 item 824 and No. 288 item 1697) | |
| 95 | General environment – noise from roads, railway and tramway lines | A-weighted equivalent sound level over the reference time T expressed by the indicators LAeqD and LaeqN (calculated) | Annex 3 to the Regulation of the Minister of the Environment of 16.06.2011 (Journal of Laws No. 140 item 824 and No. 288 item 1697) | ||
| 96 | General environment - noise from installations, equipment and industrial plants | A-weighted equivalent sound pressure level Range (25,0 – 136,0) dB |
Direct measurement method | Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (Journal of Laws of 2023, item 1706) | |
| 97 | General environment - noise from installations, equipment and industrial plants | A-weighted equivalent sound level over the reference time T expressed by the indicators LAeqD and LaeqN (calculated) | Calculation method | Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (Journal of Laws of 2023, item 1706) | |
| 98 | Rooms in residential, collective residence and public utility buildings – noise | A-weighted equivalent sound level Maximum A-weighted sound level Range (24,0 – 136,0) dB |
Direct measurement method | PN-87/B-02156 | |
| 99 | Rooms in residential, collective residence and public utility buildings – noise | A-weighted equivalent sound level for reference time T (calculated) | PN-87/B-02156 | ||
| 100 | Rooms in residential, collective residence and public buildings – noise originating from building service equipment | A-weighted equivalent sound level A-weighted maximum sound level Range (24,0 – 115,0) dB Equivalent C-weighted sound level Maximum C-weighted sound level Range (40,0 – 135,0) dB |
Direct measurement method | PN-EN ISO 10052:2007 | PN-EN ISO 10052:2007/A1:2010 | |
| 101 | Environment – rooms intended for work and human occupancy | Air flow at terminal units Range (0,4 – 30) m/s |
Anemometric method | PN-EN 12599:2013-04 | |
| 102 | Environment – rooms intended for work and human occupancy | Air change rate (calculated) | PN-EN 12599:2013-04 | ||
| 103 | Workplace environment – noise | A-weighted equivalent sound level Maximum A-weighted sound level Range (25,0 – 136,0) dB C-weighted peak sound pressure level Range (35,0 – 140,0) dB |
Direct measurement method | PN-N-01307:1994 | PN-EN ISO 9612:2011 | PN-EN ISO 9612:2025-11 | |
| 104 | Workplace environment – noise | Noise exposure level referred to: an 8-hour daily working time the average weekly working time (calculated) |
PN-N-01307:1994 | PN-EN ISO 9612:2011 | PN-EN ISO 9612:2025-11 | ||
| 105 | Workplace environment – hand-arm vibration | Frequency-weighted r.m.s. vibration acceleration Range (0,053 – 316) m/s2 |
Direct measurement method | PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11 | |
| 106 | Workplace environment – hand-arm vibration | Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the vector sum of the r.m.s. frequency-corrected vibration accelerations determined for three directional components (ahwx, ahwy, ahwz), Exposure lasting 30 minutes or less, expressed as the vector sum of the r.m.s. frequency-weighted vibration accelerations determined for three directional components (ahwx, ahwy, ahwz) (calculated) | PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11 | ||
| 107 | Workplace environment – whole-body vibration | Frequency-weighted r.m.s. vibration acceleration Range (0,018 – 100) m/s2 |
Direct measurement method | PN-EN 14253+A1:2011 | |
| 108 | Workplace environment – whole-body vibration | Daily exposure expressed as the 8-hour energy-equivalent frequency-weighted RMS vibration acceleration dominant among the vibration accelerations determined for the three directional components taking into account the appropriate coefficients (1,4awx, 1,4awy, awz), Exposure lasting 30 minutes and less, expressed as the frequency-weighted RMS vibration acceleration dominant among the vibration accelerations determined for the three directional components taking into account the appropriate coefficients (1,4awx, 1,4awy, awz), (calculated) | PN-EN 14253+A1:2011 | ||
| 109 | Workplace environment – emergency lighting | Illuminance Range (0,5 – 1000) lx |
Direct measurement method | PN-EN 1838:2013-11 excluding cl. 4.2.3, 4.2.4, 4.3.3, 4.3.4, 4.4.3, 4.4.4 and 5 | |
| 110 | Workplace environment – emergency lighting | Ratio of minimum to maximum illuminance (calculated) | PN-EN 1838:2013-11 excluding cl. 4.2.3, 4.2.4, 4.3.3, 4.3.4, 4.4.3, 4.4.4 and 5 | ||
| 111 | Workplace environment – emergency lighting | Illuminance uniformity for the high-risk zone (calculated) | PN-EN 1838:2013-11 excluding cl. 4.2.3, 4.2.4, 4.3.3, 4.3.4, 4.4.3, 4.4.4 and 5 | ||
| 112 | Workplace environment – emergency lighting | Lighting switch-on time Range (1 – 80) s |
PN-EN 1838:2013-11 excluding cl. 4.2.3, 4.2.4, 4.3.3, 4.3.4, 4.4.3, 4.4.4 and 5 | ||
| 113 | Workplace environment – emergency lighting | Minimum duration of lighting operation Range (1 – 3600) s |
PN-EN 1838:2013-11 excluding cl. 4.2.3, 4.2.4, 4.3.3, 4.3.4, 4.4.3, 4.4.4 and 5 | ||
| 114 | Workplace environment – indoor electric lighting | Illuminance Range (5 – 10000) lx |
Direct measurement method | PN-83/E-04040.03 | |
| 115 | Workplace environment – indoor electric lighting | Illuminance uniformity (calculated) | PN-83/E-04040.03 | ||
| 116 | Workplace environment – electric lighting – mining plants – underground workings | Illuminance Range (1 – 1000) lx |
Direct measurement method | PN-G-02600:1996 | |
| 117 | Workplace environment – electric lighting – mining plants – underground workings | Illuminance uniformity (calculated) | PN-G-02600:1996 | ||
| 118 | Workplace environment – electric lighting – mining plants – surface | Illuminance Range (1 – 1000) lx |
Direct measurement method | PN-G-02601:1999 | |
| 119 | Workplace environment – electric lighting – mining plants – surface | Illuminance uniformity (calculated) | PN-G-02601:1999 | ||
| 120 | Workplace environment – energy expenditure | Air temperature Range (0 – 60) °C Air flow Range (10 – 60) dm3/min |
Direct method | PB-41/W4-31.01.2018 | |
| 121 | Workplace environment – energy expenditure | Energy expenditure (calculated) | PB-41/W4-31.01.2018 | ||
| 122 | Workplace environment – hot microclimate | Air temperature Range (15 – 60) °C Natural wet bulb temperature Range (10 – 50) °C Black globe temperature Range (15 – 60) °C |
Direct measurement method | PN-EN ISO 7243:2018-01 | |
| 123 | Workplace environment – hot microclimate | WBGT index, WBGTeff index (calculated) | PN-EN ISO 7243:2018-01 | ||
| 124 | Workplace environment – cold microclimate | Air temperature Range (-30 – 10) °C Black globe temperature Range (-30 – 15) °C Air humidity Range (20 – 90) % Air velocity Range (0,15 – 5,0) m/s |
Direct measurement method | PN-EN ISO 11079:2008 | |
| 125 | Workplace environment – cold microclimate | twc index, IREQmin index, IREQneutral index (calculated) | PN-EN ISO 11079:2008 | ||
| 126 | Workplace environment – moderate microclimate | Air temperature Range (10 – 30) °C Black globe temperature Range (10 – 40) °C Air humidity Range (20 – 90) % Air velocity Range (0,15 – 1,0) m/s |
Direct measurement method | PN-EN-ISO 7730:2006 | PN-EN ISO 7730:2006+Ap2:2016-04 | |
| 127 | Workplace environment – moderate microclimate | PMV index, PPD index (calculated) | PN-EN-ISO 7730:2006 | PN-EN ISO 7730:2006+Ap2:2016-04 | ||
| 128 | Workplace environment – electromagnetic fields | Electric field strength in the frequency band 10 Hz – 400 kHz Range 1V/m – 50 kV/m |
Direct measurement method | PN-T-06580-3:2002 Method adapted to the regulated area | |
| 129 | Workplace environment – electromagnetic fields | Magnetic flux density: 0 Hz Range 0,5 mT – 1 T Magnetic flux density in the frequency band: 0,5 Hz – 400 Hz Range 0,5 mT – 46 mT Magnetic flux density in the frequency band: 10 Hz – 400 kHz Range 200 nT – 19 mT |
Direct measurement method | PN-T-06580-3:2002 Method adapted to the regulated area | |
| 130 | Workplace environment - electromagnetic field from power systems and AC electrical supply installations in the power industry | Electric field strength: in the frequency range 45 – 55 Hz Range 1 V/m – 50 kV/m Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (Journal of Laws of 2018, item 331) |
Direct measurement method | Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 91–150 | |
| 131 | Workplace environment - electromagnetic field from power systems and AC electrical supply installations in the power industry | Magnetic flux density in the frequency range 45 – 55 Hz Range 200nT – 19 mT Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (Journal of Laws of 2018, item 331) |
Direct measurement method | Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 91–150 | |
| 132 | Workplace environment - electromagnetic field in the workspace from magnetotherapy devices | Magnetic flux density in the frequency range 20 – 50 Hz Range 200nT – 19 mT Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (Journal of Laws of 2018, item 331) |
Direct measurement method (simplified) | Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 151–180 | |
| 133 | Workplace environment – non-laser optical radiation | Effective irradiance for UV in the spectral range 180 – 400 nm Range (10-6 – 39,9) W/m2 |
Direct measurement method (method A) | PN-EN 14255-1:2010 | PN-T-06589:2002 | |
| 134 | Workplace environment – non-laser optical radiation | Effective radiant exposure for UV in the spectral range 180 – 400 nm (calculated) | PN-EN 14255-1:2010 | PN-T-06589:2002 | ||
| 135 | Workplace environment – non-laser optical radiation | Irradiance for UVA in the spectral range 315 – 400 nm Range (10-3 – 3990) W/m2 |
Direct measurement method (method M) | PN-EN 14255-1:2010 | PN-T-06589:2002 | |
| 136 | Workplace environment – non-laser optical radiation | Radiant exposure for UVA in the spectral range: 315 - 400 nm (calculated) | PN-EN 14255-1:2010 | PN-T-06589:2002 | ||
| 137 | Workplace environment – non-laser optical radiation | Effective irradiance for VIS in the spectral range 300 – 700 nm Range (10-6 – 399) W/m2 |
Direct measurement method (method O) | PN-EN 14255-2:2010 | |
| 138 | Workplace environment – non-laser optical radiation | Effective radiance for VIS in the spectral range 300 – 700 nm (calculated) | PN-EN 14255-2:2010 | ||
| 139 | Workplace environment – non-laser optical radiation | Irradiance of IRA and IRB in the spectral range 780 – 3000 nm Range (30 – 3999) W/m2 |
Direct measurement method (method R) | PN-EN 14255-2:2010 | |
| 140 | Workplace environment – non-laser optical radiation | Radiant exposure of IRA and IRB in the spectral range 780 – 3000 nm (calculated) | PN-EN 14255-2:2010 | ||
| 141 | Workplace environment – non-laser optical radiation | Irradiance of VIS, IRA, IRB in the spectral range 380 – 3000 nm Range (30 – 3999) W/m2 |
Direct measurement method (method X) | PN-EN 14255-2:2010 | |
| 142 | Workplace environment – non-laser optical radiation | Radiant exposure for VIS, IRA, IRB in the spectral range: 380 – 3000 nm (calculated) | PN-EN 14255-2:2010 | ||
| 143 | Workplace environment – non-laser optical radiation | Effective irradiance for VIS, IRA in the spectral range 380 – 1400 nm Range (10-6 – 3999) W/m2 |
Direct measurement method | PN-T-05687:2002 | |
| 144 | Workplace environment – non-laser optical radiation | Effective radiance for VIS, IRA in the spectral range 380 – 1400 nm (calculated) | PN-T-05687:2002 | ||
| 145 | Workplace environment – non-laser optical radiation | Effective irradiance for IRA in the spectral range 780 – 1400 nm Range (10-3 – 3990) W/m2 |
Direct measurement method | PN-T-05687:2002 | |
| 146 | Workplace environment – non-laser optical radiation | Effective radiance for IRA in the spectral range 780 – 1400 nm (calculated) | PN-T-05687:2002 | ||
| 147 | Waste gases | Gas velocity and volume flow rate for differential pressures > 5 Pa Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Differential pressure measurement method | PN-EN ISO 16911-1:2013-07 CEN/TR 17078:2017 | |
| 148 | Waste gases | Gas volume flow rate for dynamic pressures > 10 Pa Velocity Range (0,15 – 19,5) m/s Velocity Range (0,40 – 25) m/s Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Stagnation pressure method; Thermoanemometric method; Anemometric method | PN-Z-04030-7:1994 | |
| 149 | Waste gases | Sampling for determination of dust concentration Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
PN-Z-04030-7:1994 | ||
| 150 | Waste gases | Dust concentration Range (1,0 – 100000) mg/m3 Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Gravimetric method | PN-Z-04030-7:1994 | |
| 151 | Waste gases | Dust emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
PN-Z-04030-7:1994 | ||
| 152 | Waste gases | Sampling for determination of dust concentration Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
PN-EN 13284-1:2018-02 | ||
| 153 | Waste gases | Dust concentration Range (0,5 – 50) mg/m3 Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Gravimetric method | PN-EN 13284-1:2018-02 | |
| 154 | Waste gases | Dust emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
PN-EN 13284-1:2018-02 | ||
| 155 | Waste gases | Oxygen concentration Range (0,5 – 21) % Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Paramagnetic method | PN-ISO 10396:2001 | PN-EN 14789:2017-04 | |
| 156 | Waste gases | Carbon dioxide concentration Range CO2 (0,03 – 18) % Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Method (NDIR) | PN-ISO 10396:2001 | ISO 12039:2019 | |
| 157 | Waste gases | Carbon dioxide emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
PN-ISO 10396:2001 | ISO 12039:2019 | ||
| 158 | Waste gases | Concentration of nitrogen monoxide, nitrogen oxides, NO (2 – 1300) mg/m3, NOx (3 – 2000) mg/m3 Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Chemiluminescence method | PN-ISO 10396:2001 | PN-EN 14792:2017-04 | |
| 159 | Waste gases | NO, NOx emission (NO and NO2 calculated as NO2) (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
PN-ISO 10396:2001 | PN-EN 14792:2017-04 | ||
| 160 | Waste gases | Nitrogen dioxide NO2 concentration Range (2 – 200) mg/m3 Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Chemiluminescence method | PN-ISO 10396:2001 | PN-EN 14792:2017-04 IR-394/W1-17.01.2020 | |
| 161 | Waste gases | NO2 emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
PN-ISO 10396:2001 | PN-EN 14792:2017-04 IR-394/W1-17.01.2020 | ||
| 162 | Waste gases | Carbon monoxide concentration Range CO (1,25 – 1500) mg/m3 Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Method (NDIR) | PN-ISO 10396:2001 | PN-EN 15058:2017-04 | |
| 163 | Waste gases | Carbon monoxide emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
PN-ISO 10396:2001 | PN-EN 15058:2017-04 | ||
| 164 | Waste gases | Sulfur dioxide SO2 concentration Range (20 – 2860) mg/m3 Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Method (NDIR) | PN-ISO 10396:2001 | |
| 165 | Waste gases | Sulphur dioxide emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
PN-ISO 10396:2001 | ||
| 166 | Waste gases | Concentration of organic substances in the form of gases and vapours expressed as total gaseous organic carbon Range (2 – 1000) mg/m3 Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Continuous flame ionization detection method (FID) | PN-EN 12619:2013-05 | |
| 167 | Waste gases | Emission of organic substances in gaseous and vapour form expressed as total gaseous organic carbon (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
PN-EN 12619:2013-05 | ||
| 168 | Waste gases | Water vapour concentration (H2O) range (4 – 40) % vol. Water vapour content range (29 – 250) g/m3 Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Condensation-adsorption method | PN-EN 14790:2017-4 | |
| 169 | Waste gases | Sampling for the determination of PCDD/PCDF concentration Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Filtration and condensation method | PN-EN 1948-1:2006+Ap1:2017-08 | |
| 170 | Waste gases | PCDD/PCDF emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
PN-EN 1948-1:2006+Ap1:2017-08 | ||
| 171 | Waste gases | Sampling for determination of PCB concentration Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Filtration and condensation method | PN-EN 1948-4+A1:2014-03 | |
| 172 | Waste gases | PCB emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
PN-EN 1948-4+A1:2014-03 | ||
| 173 | Waste gases – waste gas samples collected into absorbing solution | Sampling for determination of hydrogen chloride concentration Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
PN-EN 1911:2011 | ||
| 174 | Waste gases – waste gas samples collected into absorbing solution | Hydrogen chloride concentration / content Range (0,2 – 750) mg/m3 Range (0,0250 – 37,0) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Spectrophotometric method | PN-EN 1911:2011 | |
| 175 | Waste gases – waste gas samples collected into absorbing solution | Hydrogen chloride emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
PN-EN 1911:2011 | ||
| 176 | Waste gases – waste gas samples collected into absorbing solution | Sampling for determination of SO2 concentration Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
PN-EN 14791:2017-4 | ||
| 177 | Waste gases – waste gas samples collected into absorbing solution | Sulfur dioxide SO2 concentration Range (1 – 2000) mg/m3 Range (0,1 – 40) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Thoron method | PN-EN 14791:2017-4 | |
| 178 | Waste gases – waste gas samples collected into absorbing solution | Sulphur dioxide emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
PN-EN 14791:2017-4 | ||
| 179 | Waste gases – waste gas samples collected into absorbing solution | Sampling for determination of hydrogen fluoride concentration Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
ISO 15713:2006 | ||
| 180 | Waste gases – waste gas samples collected into absorbing solution | Hydrogen fluoride concentration Range (0,05 – 200) mg/m3 Range (0,0053 – 5,3) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Potentiometric method | ISO 15713:2006 | |
| 181 | Waste gases – waste gas samples collected into absorbing solution | Hydrogen fluoride emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
ISO 15713:2006 | ||
| 182 | Waste gases - waste gas samples collected into absorbing solution - waste gas samples collected on a filter | Sampling for determination of total mercury concentration Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
PN-EN 13211:2006 | ||
| 183 | Waste gases - waste gas samples collected into absorbing solution - waste gas samples collected on a filter | Total mercury emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
PN-EN 13211:2006 | ||
| 184 | Waste gases - waste gas samples collected into absorbing solution - waste gas samples collected on a filter | Sampling for determination of metal concentrations: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
PN-EN 14385:2025-05 | ||
| 185 | Waste gases - waste gas samples collected into absorbing solution - waste gas samples collected on a filter | Metal emission : As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
PN-EN 14385:2025-05 | ||
| 186 | Waste gases – waste gas samples collected into sorbent tubes | Sampling for determination of the concentration of individual gaseous organic compounds Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
PN-EN 13649:2005 | ||
| 187 | Waste gases – waste gas samples collected into sorbent tubes | Concentration / content of individual gaseous organic compounds trichloroethylene Range (0,050 – 100) mg/m3 Range (0,0010 – 2,0) mg in the sample dichloromethane Range (0,50 – 100) mg/m3 Range (0,010– 2,0) mg in the sample tetrachloroethylene Range ( 0,050 – 100) mg/m3 Range (0,0010 – 2,0) mg in the sample carbon tetrachloride Range (0,050 – 100) mg/m3 Range (0,010 – 2,0) mg in the sample ethyl alcohol Range ( 0,050 – 100) mg/m3 Range (0,0010 – 2,0) mg in the sample diethyl ether Range (0,050 – 100) mg/m3 Range (0,0010 – 2,0) mg in the sample 2-methoxymethylethoxy propanol Range (0,50 – 100) mg/m3 Range (0,010 – 2,0) mg in the sample butoxyethyl alcohol (2-butoxyethanol) Range ( 0,50 – 100) mg/m3 Range (0,010 – 2,0) mg in the sample trimethylbenzene Range (0,50 – 100) mg/m3 Range (0,010 – 1,0) mg in the sample 1-methoxypropan-2-ol Range (5,0 – 100) mg/m3 Range (0,10– 2,0) mg in the sample isopropyl alcohol (propan-2-ol) Range (5,0 – 100) mg/m3 Range (0,10 – 2,0) mg in the sample propyl alcohol (propan-1-ol) Range (5,0 – 100) mg/m3 Range (0,10 – 2,0) mg in the sample pentane Range (0,05 – 250) mg/m3 Range (0,001 – 5,0) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN 13649:2005 | |
| 188 | Waste gases – waste gas samples collected into sorbent tubes | Emission of individual gaseous organic compounds (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
PN-EN 13649:2005 | ||
| 189 | Waste gases – waste gas samples collected into sorbent tubes | Concentration / content of individual gaseous organic compounds hexane Range (0,05 – 250) mg/m3 Range (0,001 – 5,0) mg in the sample heptane Range (0,05 – 250) mg/m3 Range (0,001 – 5,0) mg in the sample octane Range (0,05 – 250) mg/m3 Range (0,001 – 5,0) mg in the sample methylcyclohexane Range (0,050 – 100) mg/m3 Range (0,0010 – 2,0) mg in the sample butan-2-ol (sec-butyl alcohol) Range (0,50 – 100) mg/m3 Range (0,010 – 2,0) mg in the sample diethylbenzene Range (0,05 – 100) mg/m3 Range (0,0010 – 2,0) mg in the sample 2-butoxyethyl acetate Range (0,050 – 100) mg/m3 Range (0,0010 – 2,0) mg in the sample sec-butyl acetate Range (0,050 – 100) mg/m3 Range (0,0010 – 2,0) mg in the sample tert-butyl acetate Range (0,050 – 100) Range (0,0010 – 2,0) mg in the sample 2-methoxy-1-methylethyl acetate Range (0,50 – 100) mg/m3 Range (0,010 – 2,0) mg in the sample isobutyl acetate Range (0,50 – 100) mg/m3 Range (0,010 – 2,0) mg in the sample acetone Range (0,050– 100) mg/m3 Range (0,0010 – 2,0) mg in the sample furfuryl alcohol (2-furylmethanol) Range (0,50 – 100) mg/m3 Range (0,010 – 2,0) mg in the sample benzene Range (0,050 – 100) mg/m3 Range (0,0010 – 2,0) mg in the sample butan-1-ol (butyl alcohol) Range (0,050 – 250) mg/m3 Range (0,0010 – 2,0) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN 13649:2005 | |
| 190 | Waste gases – waste gas samples collected into sorbent tubes | Concentration / content of individual gaseous organic compounds butan-2-one (methyl ethyl ketone) Range (0,50 – 100) mg/m3 Range (0,010 – 2,0) mg in the sample chloroform Range (0,50 – 100) mg/m3 Range (0,010 – 2,0) mg in the sample cyclohexane Range (0,050 – 100) mg/m3 Range (0,0010 – 2,0) mg in the sample cyclohexanol Range (0,50– 100) mg/m3 Range (0,010 – 2,0) mg in the sample cyclohexanone Range (0,050 – 100) mg/m3 Range (0,0010 – 2,0) mg in the sample carbon disulphide Range (0,50 – 100) mg/m3 Range (0,010 – 2,0) mg in the sample ethylbenzene Range (0,050 – 100) mg/m3 Range (0,0010 – 2,0) mg in the sample 4-hydroxy-4-methylpentan-2-one (diacetone alcohol) Range (0,50 – 100) mg/m3 Range (0,010 – 2,0) mg in the sample isopropylbenzene (cumene) Range (0,5 – 100) mg/m3 Range (0,010– 2,0) mg in the sample xylene Range (0,05 – 100) mg/m3 Range (0,0010 – 2,0) mg in the sample 4-methylpentan-2-one (methyl isobutyl ketone, hexone) Range (0,50 – 100) mg/m3 Range (0,010 – 2,0) mg in the sample 2-methylpropan-1-ol (isobutyl alcohol) Range (0,50 – 100) mg/m3 Range (0,010 – 2,0) mg in the sample mesitylene Range (0,50 – 100) mg/m3 Range (0,010 – 5,0) mg in the sample butyl acetate Range (0,50 – 100) mg/m3 Range (0,0010 – 2,0) mg in the sample ethyl acetate Range (0,050 – 100) mg/m3 Range (0,0010 – 2,0) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN 13649:2005 | |
| 191 | Waste gases – waste gas samples collected into sorbent tubes | Concentration / content of individual gaseous organic compounds vinyl acetate Range (0,50 – 100) mg/m3 Range (0,010 – 2,0) mg in the sample prop-2-en-1-ol (allyl alcohol) Range (0,050 – 100) mg/m3 Range (0,0010 – 2,0) mg in the sample propylbenzene Range (0,050 – 100) mg/m3 Range (0,0010 – 2,0) mg in the sample triethylamine Range (0,50 – 100) mg/m3 Range (0,010 – 2,0) mg in the sample styrene Range (0,50 – 100) mg/m3 Range (0,010 – 1,0) mg in the sample toluene Range (0,050 – 100) mg/m3 Range (0,0010 – 2,0) mg in the sample methanol Range (0,250 – 250) mg/m3 Range (0,0050 – 5,0) mg in the sample phenol Range (0,250 – 50) mg/m3 Range (0,0050 – 1,0) mg in the sample acetaldehyde Range (0,05 – 100) mg/m3 Range (0,001 – 2,0) mg in the sample formaldehyde Range (0,050 – 50) mg/m3 Range (0,0010 – 1,0) mg in the sample acetic acid Range (0,250 – 100) mg/m3 Range (0,0050 – 2,0) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN 13649:2005 | |
| 192 | Waste gases – waste gas samples collected into sorbent tubes | Emission of individual gaseous organic compounds (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
PN-EN 13649:2005 | ||
| 193 | Waste gases – waste gas samples collected into sorbent tubes | Sampling for determination of the concentration of aliphatic hydrocarbons Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
PN-EN 13649:2005 | ||
| 194 | Waste gases – waste gas samples collected into sorbent tubes | Concentration / content of aliphatic hydrocarbons (C5-C12) pentane Range (0,05 – 250) mg/m3 Range (0,001 – 5,0) mg in the sample hexane (0,05 – 250) mg/m3 (0,001 – 5,0) mg in the sample heptane (0,05 – 250) mg/m3 (0,001 – 5,0) mg in the sample octane (0,05 – 250) mg/m3 (0,001 – 5,0) mg in the sample nonane (0,05 – 250) mg/m3 (0,001 – 5,0) mg in the sample decane (0,05 – 250) mg/m3 (0,001 – 5,0) mg in the sample undecane (0,05 – 250) mg/m3 (0,001 – 5,0) mg in the sample dodecane (0,05 – 250) mg/m3 (0,001 – 5,0) mg in the sample Sum of aliphatic hydrocarbons (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN 13649:2005 | |
| 195 | Waste gases – waste gas samples collected into sorbent tubes | Emission of aliphatic hydrocarbons (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
PN-EN 13649:2005 | ||
| 196 | Waste gases – waste gas samples collected into sorbent tubes | Sampling for determination of the concentration of aromatic hydrocarbons Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
PN-EN 13649:2005 | ||
| 197 | Waste gases – waste gas samples collected into sorbent tubes | Concentration / content of aromatic hydrocarbons (C6-C10) 1,2,4-trimethylbenzene Range (0,050 – 50) mg/m3 Range (0,001 – 1,0) mg in the sample 1,4-diethylbenzene Range (0,050 – 50) mg/m3 Range (0,001 – 1,0) mg in the sample 1,2-diethylbenzene Range (0,050 – 50) mg/m3 Range (0,001 – 1,0) mg in the sample Sum of aromatic hydrocarbons (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN 13649:2005 | |
| 198 | Waste gases – waste gas samples collected into sorbent tubes | Emission of aromatic hydrocarbons (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
PN-EN 13649:2005 | ||
| 199 | Waste gases | Sampling for determination of the concentration of PM10, PM2,5 dust | PN-EN ISO 23210:2010 | ||
| 200 | Waste gases | PM10, PM 2,5 dust concentration Range (0,40 – 40) mg/m3 |
Gravimetric method (impactor) | PN-EN ISO 23210:2010 | |
| 201 | Waste gases | PM10, PM2,5 dust emission (calculated) | PN-EN ISO 23210:2010 | ||
| 202 | Waste gases | Dust sampling for particle size analysis | PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02 | ||
| 203 | Waste gases | Emission of the dust fraction (calculated) | PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02 | ||
| 204 | Waste gases | Sampling for determination of the concentration of organic compounds, nitrous oxide, oxygen, carbon dioxide, carbon monoxide, nitrogen, hydrogen sulfide. | Aspiration method using a Tedlar bag. | PB-109/W4-01.06.2026 | |
| 205 | Waste gases | Emission of organic compounds, nitrous oxide, oxygen, carbon dioxide, carbon monoxide, nitrogen, hydrogen sulphide (calculated) | PB-109/W4-01.06.2026 | ||
| 206 | Waste gases | Oxygen concentration O2 (0,5 – 21) % |
Electrochemical method | PN-ISO 10396:2001 | |
| 207 | Waste gases | O2 emission (calculated) | PN-ISO 10396:2001 | ||
| 208 | Waste gases | Nitrous oxide concentration N2O (4 – 700) mg/m3 |
Non-dispersive infrared spectrometry (NDIR) | PN-EN ISO 21258:2010 | |
| 209 | Waste gases | N2O emission (calculated) | PN-EN ISO 21258:2010 | ||
| 210 | Waste gases – waste gas samples collected into absorbing solution | Sampling for the determination of fluorine concentration | PB-33/W11-01.06.2026 | ||
| 211 | Waste gases – waste gas samples collected into absorbing solution | Fluorine concentration (0,09 – 60) mg/m3 (0,01 – 10) mg in the sample | Potentiometric method | PB-27/W8-29.03.2021 | |
| 212 | Waste gases – waste gas samples collected into absorbing solution | Fluorine emission (calculated) | PB-27/W8-29.03.2021 | ||
| 213 | Waste gases – waste gas samples collected into absorbing solution | Sampling for determination of, Sulfur dioxide concentration | PB-33/W11-01.06.2026 | ||
| 214 | Waste gases – waste gas samples collected into absorbing solution | Concentration / content of sulphur dioxide Range (0,05 – 32) mg/m3 Range (0,0008 – 1,6) mg in the sample |
Spectrophotometric method | PB-65/W5-17.03.2016 | |
| 215 | Waste gases – waste gas samples collected into absorbing solution | Sulphur dioxide emission (calculated) | PB-65/W5-17.03.2016 | ||
| 216 | Waste gases – waste gas samples collected into absorbing solution | Sampling for determination of sulfur trioxide concentration | PB-94/W5-01.06.2026 | ||
| 217 | Waste gases – waste gas samples collected into absorbing solution | Concentration / content of sulfur trioxide Range (2,0 – 40) mg/m3 Range (2,0 – 20,0) mg in the sample |
Thoron method | PB-95/W3-22.06.2012 | |
| 218 | Waste gases – waste gas samples collected into absorbing solution | Emission of sulphur trioxide (calculated) | PB-95/W3-22.06.2012 | ||
| 219 | Waste gases – waste gas samples collected into absorbing solution | Sampling for determination of hydrogen sulphide concentration | PB-33/W11-01.06.2026 | ||
| 220 | Waste gases – waste gas samples collected into absorbing solution | Hydrogen sulphide concentration / content Range (0,5 – 80) mg/m3 Range (0,01 – 2,0) mg in the sample |
Spectrophotometric method | PB-66/W3-17.03.2016 | |
| 221 | Waste gases – waste gas samples collected into absorbing solution | Hydrogen sulphide emission (calculated) | PB-66/W3-17.03.2016 | ||
| 222 | Waste gases – waste gas samples collected into absorbing solution | Sampling for the determination of chlorine concentration | PB-33/W11-01.06.2026 | ||
| 223 | Waste gases – waste gas samples collected into absorbing solution | Chlorine concentration / content Range (0,1 – 1,6) mg/m3 Range (0,001 – 0,032) mg in the sample |
Spectrophotometric method | PB-58/W6-17.03.2016 | |
| 224 | Waste gases – waste gas samples collected into absorbing solution | Chlorine emission (calculated) | PB-58/W6-17.03.2016 | ||
| 225 | Waste gases – waste gas samples collected into absorbing solution | Sampling for determination of phenol concentration | PB-33/W11-01.06.2026 | ||
| 226 | Waste gases – waste gas samples collected into absorbing solution | Phenol concentration / content Range (0,2 – 16) mg/m3 Range (0,002 – 0,4) mg in the sample |
Spectrophotometric method | PB-31/W7-17.03.2016 | |
| 227 | Waste gases – waste gas samples collected into absorbing solution | Phenol emission (calculated) | PB-31/W7-17.03.2016 | ||
| 228 | Waste gases – waste gas samples collected into absorbing solution | Sampling for determination of the concentration/content of formaldehyde | PB-33/W11-01.06.2026 | ||
| 229 | Waste gases – waste gas samples collected into absorbing solution | Formaldehyde concentration / content Range (0,04 – 60) mg/m3 Range (0,0004 – 0,66) mg in the sample |
Spectrophotometric method | PB-67/W3-17.03.2016 | |
| 230 | Waste gases – waste gas samples collected into absorbing solution | Formaldehyde emission (calculated) | PB-67/W3-17.03.2016 | ||
| 231 | Waste gases – waste gas samples collected into absorbing solution | Sampling for the determination of ozone concentration | Aspiration method using absorbing solutions | PB-33/W11-01.06.2026 | |
| 232 | Waste gases – waste gas samples collected into absorbing solution | Concentration / content of ozone Range (0,02 – 6,67) mg/m3 Range (0,001 – 0,20) mg in the sample |
Spectrophotometric method | PB-104/W3-17.03.2016 | |
| 233 | Waste gases – waste gas samples collected into absorbing solution | Ozone emission (calculated) | PB-104/W3-17.03.2016 | ||
| 234 | Waste gases - waste gas samples collected into absorbing solution | Sampling for determination of the concentration of NO2, NOx | PB-33/W11-01.06.2026 | ||
| 235 | Waste gases - waste gas samples collected into absorbing solution | Concentration / content of NO2 and NOx (sum of NO and NO2 expressed as NO2) Range (0,04 – 100) mg/m3 Range (0,0002 – 0,4) mg in the sample |
Spectrophotometric method | PB-59/W5-17.03.2016 | |
| 236 | Waste gases - waste gas samples collected into absorbing solution | Emission of NO2 and NOx (sum of NO and NO2 calculated as NO2) (calculated) | PB-59/W5-17.03.2016 | ||
| 237 | Waste gases - waste gas samples collected into absorbing solution | Sampling for determination of NO concentration | PB-33/W11-01.06.2026 | ||
| 238 | Waste gases - waste gas samples collected into absorbing solution | Concentration / content of NO Range ( 0,026 – 65,2) mg/m3 Range (0,00013- 0,26) mg in the sample |
Spectrophotometric method | PB-59/W5-17.03.2016 | |
| 239 | Waste gases - waste gas samples collected into absorbing solution | NO emission (calculated) | PB-59/W5-17.03.2016 | ||
| 240 | Waste gases - waste gas samples collected into absorbing solution | Sampling for determination of ammonia concentration | PN-EN ISO 21877:2020-03 | ||
| 241 | Waste gases - waste gas samples collected into absorbing solution | Ammonia concentration / content Range (0,1 – 150) mg/m3 Range (0,000145 – 0,045) mg/ml |
Spectrophotometric method | PN-EN ISO 21877:2020-03 | |
| 242 | Waste gases - waste gas samples collected into absorbing solution | Ammonia emission (calculated) | PN-EN ISO 21877:2020-03 | ||
| 243 | Waste gases - waste gas samples collected into absorbing solution - waste gas samples collected on a filter | Sampling for determination of metal concentrations Fe, Al, | PN-EN 14385:2025-05 | ||
| 244 | Waste gases - waste gas samples collected into absorbing solution - waste gas samples collected on a filter | Emission of Fe, Al (calculated) | PN-EN 14385:2025-05 | ||
| 245 | Waste gases - waste gas samples collected into absorbing solution - waste gas samples collected on a filter | Sampling for determination of metal concentrations Ba, Bi, Zn, Sn, Mo, Se, Ag | PN-EN 14385:2025-05 | ||
| 246 | Waste gases - waste gas samples collected into absorbing solution - waste gas samples collected on a filter | Emission of Ba, Bi, Zn, Sn, Mo, Se, Ag (calculated) | PN-EN 14385:2025-05 | ||
| 247 | Waste gases – waste gas samples collected on a filter | Sampling for determination of sulfuric acid concentration | PB-97/W5-01.06.2026 | ||
| 248 | Waste gases – waste gas samples collected on a filter | Concentration / content of sulphuric acid Range (0,2 – 4,0) mg/m3 Range (0,20 – 1,0) mg in the sample |
Turbidimetric method | PB-69/W4-18.03.2015 | |
| 249 | Waste gases – waste gas samples collected on a filter | Sulfuric acid emission (calculated) | PB-69/W4-18.03.2015 | ||
| 250 | Waste gases – waste gas samples collected on a filter | Sampling for determination of the concentration of isocyanates: 2,4-TDI, 2,6-TDI, MDI, HDI | Aspiration method using filters | PB-105/W2-03.08.2015 | |
| 251 | Waste gases – waste gas samples collected on a filter | Concentration / content of isocyanates Range 2,4-TDI (toluene-2,4- diyl; 2,4-diisocyanatotoluene) Range (0,0001 – 0,2) mg/m3 Range (0,10 – 50,0) μg in the sample 2,6-TDI ( toluene-2,6-diyl diisocyanate; toluene 2,6-diisocyanate) Range (0,0001 – 0,2) mg/m3 Range (0,10 – 50,0) μg in the sample MDI (methylenebis (phenyl isocyanate), 4,4’-methylenebis(phenyl isocyanate) Range (0,0001 – 0,2) mg/m3 Range (0,10 – 50,0) μg in the sample HDI (hexane-1,6-diyl diisocyanate; hexamethylene 1,6-diisocyanate) Range (0,0001 – 0,2) mg/m3 Range (0,10 – 50,0) μg in the sample |
High-performance liquid chromatography with fluorescence detection (HPLC-FLD) | PB-103/W2-18.03.2015 * | |
| 252 | Waste gases – waste gas samples collected on a filter | Isocyanate emission (calculated) | PB-103/W2-18.03.2015 * | ||
| 253 | Waste gases – waste gas samples collected on a filter, sorbent and into an absorbing solution | Sampling for the determination of PAH concentration | ISO 11338-1:2003 | ||
| 254 | Waste gases – waste gas samples collected on a filter, sorbent and into an absorbing solution | Concentration / content of PAH naphthalene acenaphthalene phenanthrene fluoranthene benzo(a)anthracene benzo(k)fluoranthene benzo(a)pyrene dibenzo(a,h)anthracene fluorene anthracene pyrene chrysene benzo(b)fluoranthene indeno(1,2,3-cd)pyrene benzo(ghi)perylene Range (0,00005 – 1) mg/m3 Range (0,050 – 5,0) μg in the sample Sum of aromatic hydrocarbons (calculated) |
High-performance liquid chromatography with fluorescence detection (HPLC-FLD) | ISO 11338-2:2003 * | |
| 255 | Waste gases – waste gas samples collected on a filter, sorbent and into an absorbing solution | Emission of PAHs: naphthalene, acenaphthylene, phenanthrene, fluoranthene, benzo(a)anthracene, benzo(k)fluoranthene, benzo(a)pyrene dibenzo(a,h)anthracene, fluorene, anthracene, pyrene, chrysene, benzo(b)fluoranthene, indeno(1,2,3-cd)pyrene, benzo(g,h,i)perylene (calculated) | ISO 11338-2:2003 * | ||
| 256 | Waste gas dedusting equipment | Dust concentration Range (1,0 – 100000) mg/m3 |
Gravimetric method | PN-EN 13284-1:2018-02 | PN-Z-04030-7:1994 | PN-87/M-34129 Method A | |
| 257 | Waste gas dedusting equipment | Dust removal efficiency (calculated) | PN-EN 13284-1:2018-02 | PN-Z-04030-7:1994 | PN-87/M-34129 Method A | ||
| 258 | Waste gas cleaning installations | Sulfur dioxide SO2 concentration Range (1,0 – 2000) mg/m3 |
Thoron method | PN-EN 14791:2017-4 | PB-35/W5-01.06.2026 | |
| 259 | Waste gas cleaning installations | SO2 reduction efficiency (calculated) | PN-EN 14791:2017-4 | PB-35/W5-01.06.2026 | ||
| 260 | Waste gas cleaning installations | Sulfur dioxide SO2 concentration Range (20 – 2860) mg/m3 |
NDIR method | PN-ISO 10396:2001 | PB-35/W5-01.06.2026 | |
| 261 | Waste gas cleaning installations | SO2 reduction efficiency (calculated) | PN-ISO 10396:2001 | PB-35/W5-01.06.2026 | ||
| 262 | Waste gas cleaning installations | Concentration of nitrogen monoxide, nitrogen oxides NO (2 – 1300) mg/m3 NOx (3 – 2000) mg/m3 |
Chemiluminescence method | PN-ISO 10396:2001 | PN-EN 14792:2017-04 | PB-35/W5-01.06.2026 | |
| 263 | Waste gas cleaning installations | NO, NOx reduction efficiency (calculated) | PN-ISO 10396:2001 | PN-EN 14792:2017-04 | PB-35/W5-01.06.2026 | ||
| 264 | Waste gas cleaning installations | Concentration of organic substances in the form of gases and vapours expressed as total gaseous organic carbon Range (2 – 1000) mg/m3 |
Continuous flame ionization detection method (FID) | PN-EN 12619:2013-05 | PB-35/W5-01.06.2026 | |
| 265 | Waste gas cleaning installations | Reduction efficiency of organic substances in the form of gases and vapours expressed as total gaseous organic carbon (calculated) | PN-EN 12619:2013-05 | PB-35/W5-01.06.2026 | ||
| 266 | Waste gas cleaning installations | PAH concentration Range (0,00005 – 1) mg/m3 |
High-performance liquid chromatography with fluorescence detection (HPLC-FLD) | ISO 11338-1:2003 * | ISO 11338-2:2003 * | PB-35/W5-01.06.2026* | |
| 267 | Waste gas cleaning installations | PAH reduction efficiency (calculated) | ISO 11338-1:2003 * | ISO 11338-2:2003 * | PB-35/W5-01.06.2026* | ||
| 268 | Automated Measuring Systems (AMS) | AMS calibration (QAL2) for: Hg, NH3, N2O | PN-EN 14181:2015-02 | ||
| 269 | Automated Measuring Systems (AMS) | Annual surveillance test (AST) for: Hg, NH3, N2O | PN-EN 14181:2015-02 | ||
| 270 | Automated Measuring Systems (AMS) | Mercury concentration Range (0,025 – 104) μg/m3 |
Cold vapour atomic absorption spectrometry (CVAAS) | PN-EN 13211:2006 | |
| 271 | Automated Measuring Systems (AMS) | Ammonia concentration Range (0,1 – 150) mg/m3 |
Spectrophotometric method | PN-EN ISO 21877:2020-03 | |
| 272 | Automated Measuring Systems (AMS) | N2O concentration Range (4 – 700) mg/m3 |
Non-dispersive infrared spectrometry (NDIR) | PN-EN ISO 21258:2010 | |
| 273 | Automated Measuring Systems (AMS) | N2O emission (calculated) | PN-EN ISO 21258:2010 | ||
| 274 | Automated Measuring Systems (AMS) | AMS calibration (QAL2) for: dust, SO2, CO2, HCl, HF, TVOC, H2O, CO, NO, NO2, NOx, O2 Regulated area: Continuous measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
PN-EN 14181:2015-02 | ||
| 275 | Automated Measuring Systems (AMS) | Annual surveillance test (AST) for: dust, SO2, CO2, HCl, HF, TVOC, H2O, CO, NO, NO2, NOx, O2 Regulated area: Continuous measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
PN-EN 14181:2015-02 | ||
| 276 | Automated Measuring Systems (AMS) | Dust concentration Range (1 – 100000) mg/m3 Regulated area: Continuous measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Gravimetric method | PN-Z-04030-7:1994 | |
| 277 | Automated Measuring Systems (AMS) | Dust concentration Range (0,5 – 50) mg/m3 Regulated area: Continuous measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Gravimetric method | PN-EN 13284-1:2018-02 | |
| 278 | Automated Measuring Systems (AMS) | SO2 concentration Range (1 – 2000) mg/m3 Regulated area: Continuous measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Thoron method | PN-EN 14791:2017-4 | |
| 279 | Automated Measuring Systems (AMS) | CO2 concentration Range (0,03 – 18) % Regulated area: Continuous measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
NDIR method | PN-ISO 10396:2001 | ISO 12039:2019 | |
| 280 | Automated Measuring Systems (AMS) | O2 concentration Range (3,0 – 21) % Regulated area: Continuous measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Paramagnetic method | PN-EN 14789:2017-04 | |
| 281 | Automated Measuring Systems (AMS) | NO, NOx concentration, NO (2 – 1300) mg/m3, NOx (3 – 2000) mg/m3 Regulated area: Continuous measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Chemiluminescence method | PN-EN 14792:2017-04 | |
| 282 | Automated Measuring Systems (AMS) | Nitrogen dioxide NO2 concentration Range (2 – 200) mg/m3 Regulated area: Continuous measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Chemiluminescence method | PN-EN 14792:2017-04 IR-394/W1-17.01.2020 | |
| 283 | Automated Measuring Systems (AMS) | NO2 emission (calculated) Regulated area: Continuous measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
PN-EN 14792:2017-04 IR-394/W1-17.01.2020 | ||
| 284 | Automated Measuring Systems (AMS) | CO concentration Range (1,25 – 1500) mg/m3 Regulated area: Continuous measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
NDIR method | PN-ISO 10396:2001 | PN-EN 15058:2017-04 | |
| 285 | Automated Measuring Systems (AMS) | Hydrogen chloride concentration Range (0,2 – 750) mg/m3 Regulated area: Continuous measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Spectrophotometric method | PN-EN 1911:2011 | |
| 286 | Automated Measuring Systems (AMS) | Hydrogen fluoride concentration Range (0,05 – 200) mg/m3 Regulated area: Continuous measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Potentiometric method | ISO 15713:2006 | |
| 287 | Automated Measuring Systems (AMS) | Concentration of organic substances in the form of gases and vapours expressed as total gaseous organic carbon Range (2 – 1000) mg/m3 Regulated area: Continuous measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Continuous flame ionization detection method (FID) | PN-EN 12619:2013-05 | |
| 288 | Automated Measuring Systems (AMS) | Water vapour concentration (H2O) Range (4 – 40) % vol. Water vapour content range (29 – 250) g/m3 Regulated area: Continuous measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Condensation-adsorption method | PN-EN 14790:2017-4 | |
| 289 | General environment air – immission | Dust sampling Dust deposition Range (1 – 1110) g/m2 |
Deposition method (settling particulate matter) | ASTM D 1739-98(2017) | PB-64/W2-22.06.2012 | |
| 290 | Dust samples | Concentration of dust fractions (particle size distribution) including PM2,5 and PM10 Range (0,01 – 2100) um |
Laser diffraction method with liquid dispersion | ISO 13320:2020 | ISO 14488:2007 | |
Reference standards (152)
ASTM D 1739-98(2017)
ISO 11338-1:2003
ISO 11338-1:2003 *
ISO 11338-2:2003 *
ISO 12039:2019
ISO 13320:2020
ISO 14488:2007
ISO 15713:2006
PB-03/CzG/W8-22.01.2018
PB-07/W7-10.09.2021
PB-102/W2-18.03.2015 *
PB-103/W2-18.03.2015 *
PB-104/W3-17.03.2016
PB-105/W2-03.08.2015
PB-109/W4-01.06.2026
PB-27/W8-29.03.2021
PB-31/W7-17.03.2016
PB-33/W11-01.06.2026
PB-35/W5-01.06.2026
PB-35/W5-01.06.2026*
PB-41/W4-31.01.2018
PB-58/W6-17.03.2016
PB-59/W5-17.03.2016
PB-61/CzA/W6-24.01.2018
PB-61/CzC/W5-24.01.2018
PB-61/CzD/W2-01.04.2015 *
PB-64/W2-22.06.2012
PB-65/W5-17.03.2016
PB-66/W3-17.03.2016
PB-67/W3-17.03.2016
PB-69/W4-18.03.2015
PB-94/W5-01.06.2026
PB-95/W3-22.06.2012
PB-97/W5-01.06.2026
PN-71/Z-04041
PN-75/Z-04037.03
PN-77/Z-04074.02
PN-77/Z-04110.01
PN-78/Z-04047.02
PN-78/Z-04118.01
PN-79/Z-04081.01
PN-81/Z-04031.02
PN-81/Z-04134.02
PN-81/Z-04134.03
PN-83/E-04040.03
PN-84/Z-04138.02
PN-86/Z-04151.02
PN-86/Z-04152.02
PN-86/Z-04158.02
PN-86/Z-04165.02
PN-86/Z-04166.02
PN-87/B-02156
PN-87/M-34129 Method A
PN-88/Z-04187.02
PN-89/Z-04023.02 IR-230/W5-08.03.2019
PN-EN 12341:2024-01
PN-EN 12599:2013-04
PN-EN 12619:2013-05
PN-EN 13211:2006
PN-EN 13284-1:2018-02
PN-EN 13649:2005
PN-EN 14181:2015-02
PN-EN 14253+A1:2011
PN-EN 14255-1:2010
PN-EN 14255-2:2010
PN-EN 14385:2025-05
PN-EN 14789:2017-04
PN-EN 14790:2017-4
PN-EN 14791:2017-4
PN-EN 14792:2017-04
PN-EN 14792:2017-04 IR-394/W1-17.01.2020
PN-EN 15058:2017-04
PN-EN 1838:2013-11 excluding cl. 4.2.3, 4.2.4, 4.3.3, 4.3.4, 4.4.3, 4.4.4 and 5
PN-EN 1911:2011
PN-EN 1948-1:2006+Ap1:2017-08
PN-EN 1948-4+A1:2014-03
PN-EN ISO 10052:2007
PN-EN ISO 10052:2007/A1:2010
PN-EN ISO 11079:2008
PN-EN ISO 16911-1:2013-07 CEN/TR 17078:2017
PN-EN ISO 21258:2010
PN-EN ISO 21877:2020-03
PN-EN ISO 23210:2010
PN-EN ISO 3746:2011+Ap1:2017-09
PN-EN ISO 5349-1:2004
PN-EN ISO 5349-2:2004
PN-EN ISO 5349-2:2004/A1:2015-11
PN-EN ISO 7243:2018-01
PN-EN ISO 7730:2006+Ap2:2016-04
PN-EN ISO 9612:2011
PN-EN ISO 9612:2025-11
PN-EN-ISO 7730:2006
PN-G-02600:1996
PN-G-02601:1999
PN-ISO 10396:2001
PN-N-01307:1994
PN-N-01339:2000 Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (Journal of Laws of 2023, item 1706)
PN-T-05687:2002
PN-T-06580-3:2002 Method adapted to the regulated area
PN-T-06589:2002
PN-Z-04007-2:1994
PN-Z-04008-7:2002+Az1:2004
PN-Z-04009-11:2008
PN-Z-04015-12:1996+Ap1:2001
PN-Z-04015-13:1996
PN-Z-04015-15:1999
PN-Z-04016-10:2005
PN-Z-04016-4:1998
PN-Z-04016-6:1998
PN-Z-04016-8:1999
PN-Z-04030-7:1994
PN-Z-04073-1:2014-08
PN-Z-04098-3:2005
PN-Z-04108-5:2006
PN-Z-04119-10:2008/Ap1:2011
PN-Z-04119-11:2008/Ap1:2011
PN-Z-04119-2:1998
PN-Z-04119-3:1998
PN-Z-04136-3:2003
PN-Z-04137-02:1984
PN-Z-04155-4:1996
PN-Z-04159-10:1989
PN-Z-04214-02:1990
PN-Z-04224-02:1992
PN-Z-04224-3:2003
PN-Z-04227-02:1992
PN-Z-04240-2:1999 *
PN-Z-04240-4:1999 *
PN-Z-04240-5:2006 *
PN-Z-04265:2000
PN-Z-04304:2003
PN-Z-04318:2005
PN-Z-04323:2004
PN-Z-04346:2006
PN-Z-04354:2005
PN-Z-04368:2008
PN-Z-04374:2009
PN-Z-04447:2014-06
PN-Z-04448:2014-06
PN-Z-04449:2014-06
PN-Z-04450:2014-08
PN-Z-04507:2022-05
PN-Z-04507:2022-05/Ap1:2022-08
PN-Z-04508:2022-05
PN-Z-04508:2022-05/Ap1:2022-08
Principles and Methods of Assessing the Working Environment 2003, No. 4 (38), pp. 149–155
Principles and Methods of Assessing the Working Environment 2012, No. 4 (74), pp. 117–130
Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 151–180
Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 91–150
Principles and Methods of Assessing the Working Environment 2017, No. 2 (92), pp. 173–188
Annex 3 to the Regulation of the Minister of the Environment of 16.06.2011 (Journal of Laws No. 140 item 824 and No. 288 item 1697)
Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (Journal of Laws of 2023, item 1706)