🇵🇱 MIEJSKIE WODOCIĄGI I OCZYSZCZALNIA Sp. z o.o. PL

PCA AB 680 • Grudziądz, Poland • 139 methods

Water & wastewaterEnvironmentMicrobiologyMaterials & polymers

MIEJSKIE WODOCIĄGI I OCZYSZCZALNIA Sp. z o.o. is a laboratory accredited by PCA under number AB 680 (Grudziądz, Poland). Its accreditation scope covers 139 test methods in the following areas: Water & wastewater, Environment, Microbiology, Materials & polymers. Test objects include: Water, Wastewater, Sewage sludge, Water (including swimming pool water). Most frequently used techniques: Spectrophotometric method, Gravimetric method, Titrimetric method.

At a glance

  • Accreditation number: PCA AB 680
  • Methods in scope: 139
  • Types of test objects: 24
  • Techniques used: 29
  • City: Grudziądz, Poland
Accreditation number
AB 680
Accreditation body
PCA
Address
ul. Mickiewicza 28/30, 86-300 Grudziądz, LABORATORIUM CENTRALNE, ul. Curie-Skłodowskiej 10
City
Grudziądz, Poland

What this laboratory tests (24)

Analytical techniques used (29)

Laboratory locations

Certificate information

Issue date
19.12.2025
Issue no.
23

Accreditation scope — test methods (139)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Swimming pool water Sampling for chemical and physical testing PL-IO-22 issue 01 of 15.01.2017
2 Surface water Sampling for chemical and physical testing PN-EN ISO 5667-6:2016-12 excluding cl. 7.5, 7.6
3 Water, water intended for human consumption Sampling for chemical and physical testing Temperature of the water sample taken
Range (1,0 – 60,0)°C
PN-ISO 5667-5:2017-10 | PN-77/C-04584
4 Groundwater Sampling for chemical and physical testing Temperature of the water sample taken
Range (1,0 – 60,0)°C
PN-ISO 5667-11:2017-10 excluding cl. 5.2, 6.2, 6.3 | PN-77/C-04584
5 Water (including swimming pool water) Free, + total chlorine concentration
Range (0,02 – 2,00) mg/l Combined chlorine concentration (calculated)
Colorimetric method PL-PB-30 issue 06 of 28.10.2025 | based on the HACH method No. 8021 and 8167
6 Water (including swimming pool water) Turbidity
Range (0,10 − 40) NTU
Nephelometric method PN-EN ISO 7027-1:2016-09
7 Water (including swimming pool water) Permanganate index
Range (0,5 − 7,0) mg/l O2
Titrimetric method PN-EN ISO 8467:2001
8 Water (including swimming pool water) Nitrate nitrogen concentration
Range (0,04 – 11,3) mg/l
Spectrophotometric method PN-82/C-04576/08
9 Water, water intended for human consumption Odour threshold number
Range (1 – 2) TON
Paired method, simplified, non-forced choice PN-EN 1622:2006
10 Water intended for human consumption Taste threshold number
Range (1 – 2) TFN
Paired method, simplified, non-forced choice PN-EN 1622:2006
11 Water pH
Range 3,0 – 10,0
Potentiometric method PN-EN ISO 10523:2012
12 Water Electrical conductivity
Range (5 − 5000) μS/cm
Conductometric method PN-EN 27888:1999
13 Water Total content of calcium and magnesium (total hardness)
Range (5 − 500) mg/l CaCO3 Range (0,05 – 5) mmol/l
Titrimetric method PN-ISO 6059:1999
14 Water Total alkalinity
Range (4,0 – 10,0) mmol/l
Titrimetric method PN-EN ISO 9963-1:2001 cl. 8.2.2 + Ap1:2004
15 Water Bicarbonates (HCO3-) (calculated) PN-EN ISO 9963-1:2001 cl. 8.2.2 + Ap1:2004
16 Water Colour
Range (5 − 50) mg/l Pt
Visual method PN-EN ISO 7887:2012 cl. 7 + Ap1:2015-06
17 Water Colour
Range (5 − 250) mg/l Pt
Spectrophotometric method PN-EN ISO 7887:2012 cl. 6 + Ap1:2015-06
18 Water Dissolved solids, dry residue
Range (300 − 1600) mg/l
Gravimetric method PN-78/C-04541
19 Water Manganese concentration
Range (50 – 1000) μg/l
Spectrophotometric method PN-92/C-04590/02
20 Water Calcium concentration
Range (2 − 140) mg/l Calcium hardness Range (0,05 – 3,5) mmol/l
Titrimetric method PN-ISO 6058:1999
21 Water Magnesium concentration (calculated) PN-C-04554-4:1999 Annex A
22 Water Orthophosphate concentration
Range (0,025 − 0,80) mg/l
Spectrophotometric method PN-EN ISO 6878:2006 cl. 4 + Ap1:2010+Ap2:2010
23 Water Silica concentration
Range (5,0 − 50) mg/l
Spectrophotometric method PN-71/C-04567/02
24 Water Chromium(VI) concentration
Range (2 – 50) μg/l
Spectrophotometric method PN-EN ISO 18412:2007
25 Water Kjeldahl nitrogen concentration
Range (1,0 − 5,0) mg/l
Titrimetric method PN-EN 25663:2001
26 Water Biochemical oxygen demand (BOD5)
Range (3,0 – 6000) mg/l O2
Electrochemical method PN-EN ISO 5815-1:2019-12
27 Water Total suspended solids (TSS)
Range (2,0 − 50) mg/l
Gravimetric method PN-EN 872:2007+Ap1:2007
28 Water Ammonium nitrogen concentration
Range (0,05 – 10,0) mg/l
Spectrophotometric method PN-ISO 7150-1:2002
29 Water Nitrite nitrogen concentration
Range (0,010 – 0,30) mg/l
Spectrophotometric method PN-EN 26777:1999
30 Water Chloride concentration
Range (5 − 3000) mg/l
Titrimetric method PN-ISO 9297:1994
31 Water Sulfate concentration
Range (10 − 500) mg/l
Gravimetric method PN-ISO 9280:2002
32 Water Chemical oxygen demand (SP-COD)
Range (5,0 − 150) mg/l O2
Spectrophotometric method PN-ISO 15705:2005
33 Water Total phosphorus concentration
Range (0,06 – 5,00) mg/l
Spectrophotometric method PN-EN ISO 6878:2006 cl. 7 + Ap1:2010+Ap2:2010
34 Water, wastewater Total iron concentration
Range (10 – 10000) μg/l
Spectrophotometric method PN-ISO 6332:2001 + Ap1:2016-06
35 Water, wastewater Free cyanide concentration
Range (10 – 600) μg/l
Spectrophotometric method PL-PB-12 issue 02 of 15.05.2014 | based on the Hach Lange cuvette test No. 315
36 Water, wastewater Biochemical oxygen demand (BOD5)
Range (0,5 – 6) mg/l O2
Electrochemical method PN-EN 1899-2:2002
37 Water, wastewater Dissolved oxygen concentration
Range (0,5 – 15) mg/l O2 % oxygen saturation Range (5 – 150) %
Electrochemical method PN-EN ISO 5814:2013
38 Water, wastewater Total nitrogen concentration (calculated) PL-PB-27 issue 03 of 01.10.2019
39 Wastewater Sampling for chemical and physical testing
Temperature of the collected wastewater sample Range (1,0 – 60,0) °C
Manual and automatic method PN-ISO 5667-10:2021-11 | PN-77/C-04584
40 Wastewater pH
Range 3,0 – 10,0
Potentiometric method PN-EN ISO 10523:2012
41 Wastewater Biochemical oxygen demand BOD5
Range (3,0 − 6000) mg/l O2
Electrochemical method PN-EN ISO 5815-1:2019-12
42 Wastewater Total nitrogen concentration
Range (1,00 − 100) mg/l
Spectrophotometric method PL-PB-17 issue 04 of 16.11.2017 | based on the Hach Lange cuvette test No. 138, No. 238, No. 338
43 Wastewater Total phosphorus concentration
Range (0,06 – 80,0) mg/l
Spectrophotometric method PN-EN ISO 6878:2006 cl. 7 + Ap1:2010+Ap2:2010
44 Wastewater Ether extract concentration
Range (5 − 200) mg/l
Gravimetric method PL-PB-05 issue 03 of 15.09.2014
45 Wastewater Kjeldahl nitrogen concentration
Range (1,0 − 500) mg/l
Titrimetric method PN-EN 25663:2001
46 Wastewater Chromium(VI) concentration
Range (0,02 − 7,5) mg/l
Spectrophotometric method PN-77/C-04604/08
47 Wastewater Electrical conductivity
Range (5 − 5000) μS/cm
Conductometric method PN-EN 27888:1999
48 Wastewater Total suspended solids (TSS)
Range (2,0 − 2000) mg/l
Gravimetric method PN-EN 872:2007+Ap1:2007
49 Wastewater Ammonium nitrogen concentration
Range (0,05 – 80,0) mg/l
Spectrophotometric method PN-ISO 7150-1:2002
50 Wastewater Nitrite nitrogen concentration
Range (0,010 − 10) mg/l
Spectrophotometric method PN-EN 26777:1999
51 Wastewater Nitrate nitrogen concentration
Range (0,04 − 35,0) mg/l
Spectrophotometric method PN-82/C-04576/08
52 Wastewater Chloride concentration
Range (5 − 3000) mg/l
Titrimetric method PN-ISO 9297:1994
53 Wastewater Sulfate concentration
Range (10 − 500) mg/l
Gravimetric method PN-ISO 9280:2002
54 Wastewater Chemical oxygen demand (SP-COD)
Range (5,0 − 10 000) mg/l O2
Spectrophotometric method PN-ISO 15705:2005
55 Sewage sludge Sampling for chemical, physical, microbiological and biological testing PN-EN ISO 5667-13:2011 excluding cl. 6.3.3, 6.3.4, 6.3.5, 6.3.10
56 Sewage sludge pH – in H2O
Range 3,0 − 12,0
Potentiometric method PN-EN ISO 10390:2022-09
57 Sewage sludge Total Kjeldahl nitrogen content
Range (0,25 − 13,0) %
Titrimetric method PN-EN 13342:2002
58 Sewage sludge Dry matter content
Range (1,00 − 80,0) %
Gravimetric method PN-EN 15934:2013-02 excluding Method B
59 Sewage sludge Water content (calculated) PN-EN 15934:2013-02 excluding Method B
60 Sewage sludge Loss on ignition (organic matter)
Range (10,0 − 85,0) %
Gravimetric method PN-EN 15935:2022-01
61 Sewage sludge Residue on ignition (mineral substances) (calculated) PN-EN 15935:2022-01
62 Sludges, plant cultivation aids: - soil improvers Ammonium nitrogen content
Range (0,10 − 9,00) %
Titrimetric method PN-75/C-04576-15
63 Sludges, plant cultivation aids: - soil improvers Total phosphorus content
Range (0,10 − 6,0) %
Spectrophotometric method PN-EN 14672:2006
64 Plant cultivation aids: - soil improvers Sampling for chemical, physical, microbiological and biological testing PN-ISO 12579:2013
65 Plant cultivation aids: - soil improvers Total nitrogen content
Range (1,00 − 7,00) %
Titrimetric method PL-PB-28 issue 04 of 20.08.2019
66 Plant cultivation aids: - soil improvers Dry matter content
Range (37,0 − 97,0) %
Gravimetric method PN-EN 13040:2009
67 Plant cultivation aids: - soil improvers Water content (calculated) PN-EN 13040:2009
68 Plant cultivation aids: - soil improvers Loss on ignition (organic matter)
Range (18,0 − 62,0) %
Gravimetric method PN-EN 13039:2011
69 Plant cultivation aids: - soil improvers Residue on ignition (mineral substances) (calculated) PN-EN 13039:2011
70 Soil Sampling for chemical and physical testing PN-R-04031:1997
71 Soil pH – in H2O
Range 3,0 − 10,0
Potentiometric method PN-EN ISO 10390:2022-09
72 Soil Dry matter content
Range (75,0 − 99,5) %
Gravimetric method PN-EN 15934:2013-02 excluding Method B
73 Soil Water content (calculated) PN-EN 15934:2013-02 excluding Method B
74 Soil Loss on ignition (organic matter)
Range (1,50 − 18,0) %
Gravimetric method PN-EN 15935:2022-01
75 Soil Residue on ignition (mineral substances) (calculated) PN-EN 15935:2022-01
76 Mineral soil Available phosphorus content
Range (3,2 − 45) mg P2O5/100 g
Spectrophotometric method PN-R-04023:1996
77 Landfill gases Concentration of: methane, carbon dioxide
CH4 (0,7 − 70,0) % CO2 (0,6 − 25,0) % Oxygen concentration O2 (0,5 – 20,0) %
NDIR method; Electrochemical method PL-PB-26 issue 04 of 24.11.2020
78 Landfill gases Gas flow velocity
Range (1,0 – 5,0) m/s CH4 and CO2 emission (calculated)
Thermoanemometric method PL-PB-26 issue 04 of 24.11.2020
79 Waste: code 19 05 03, 19 05 99, 19 08 01, 19 08 02, 19 08 05, 19 12 12, 20 03 03, 20 03 06 Sampling for chemical and physical testing PL-IO-23 issue 05 of 20.10.2022
80 Waste: code 19 05 99, 19 12 12 Oxygen demand (AT4)
Range (0,60 − 40,0) mg O2/g
Manometric method PL-PB-13 issue 03 of 10.09.2021
81 Waste: code 19 05 03, 19 05 99, 19 12 12, Dry residue (dry matter)
Range (40,0 − 98,0) %
Gravimetric method PN-EN 15934:2013-02 excluding Method B
82 Waste: code 19 05 03, 19 05 99, 19 12 12, Water content (calculated) PN-EN 15934:2013-02 excluding Method B
83 Waste: code 19 05 03, 19 05 99, 19 12 12, Loss on ignition Organic substances
Range (10,0 − 30,0) %
Gravimetric method PN-EN 15935:2022-01
84 Waste: code 19 05 03, 19 05 99, 19 12 12, Residue on ignition (mineral substances) (calculated) PN-EN 15935:2022-01
85 Waste: code 19 08 01 Dry residue (dry matter)
Range (10,0 − 80,0) %
Gravimetric method PN-EN 15934:2013-02 excluding Method B
86 Waste: code 19 08 01 Water content (calculated) PN-EN 15934:2013-02 excluding Method B
87 Waste: code 19 08 01 Loss on ignition Organic substances
Range (70,0 − 98,0) %
Gravimetric method PN-EN 15935:2022-01
88 Waste: code 19 08 01 Residue on ignition (mineral substances) (calculated) PN-EN 15935:2022-01
89 Waste: code 19 08 02 Dry residue (dry matter)
Range (75,0 − 99,5) %
Gravimetric method PN-EN 15934:2013-02 excluding Method B
90 Waste: code 19 08 02 Water content (calculated) PN-EN 15934:2013-02 excluding Method B
91 Waste: code 19 08 02 Loss on ignition Organic substances
Range (1,50 − 20,0) %
Gravimetric method PN-EN 15935:2022-01
92 Waste: code 19 08 02 Residue on ignition (mineral substances) (calculated) PN-EN 15935:2022-01
93 Soil Metal content
Pb (2,5 –100) mg/kg Cu (2,5 –100) mg/kg Cd (0,10 – 100) mg/kg Zn (2,5 – 500) mg/kg Cr (2,5 – 200) mg/kg Ni (2,5 – 100) mg/kg
Inductively coupled plasma mass spectrometry (ICP-MS) PN-EN 16171:2017-02
94 Soil Total organic carbon (TOC) content
Range (0,50 – 7,9) %
Spectrometry method in the infrared range IR PN-EN 15936:2022-07 excluding Method A
95 Soil Mercury content
Range (0,013 – 3,3) mg/kg
Cold vapour atomic absorption spectrometry (CVAAS) PN-EN 16175-1:2017-02
96 Mineral soil Available magnesium content
Range (6,0 – 30) mg Mg/100 g
Flame atomic absorption spectrometry (FAAS) PN-R-04020:1994 +Az1:2004
97 Mineral soil Available potassium content
Range (7,0 – 60) mg K2O/100 g
Flame atomic absorption spectrometry (FAAS) PN-R-04022:1996 +Az1:2002
98 plant growth aids: - soil improvers Metal content
Pb (2,5 – 200) mg/kg Cd (0,10 – 100) mg/kg Cr (2,5 – 200) mg/kg Ni (2,5 – 100) mg/kg
Inductively coupled plasma mass spectrometry (ICP-MS) PN-EN 16171:2017-02
99 plant growth aids: - soil improvers Mercury content
Range (0,013 – 33) mg/kg
Cold vapour atomic absorption spectrometry (CVAAS) PN-EN 16175-1:2017-02
100 plant growth aids: - soil improvers Potassium content
Range (0,13 – 1,32) % m/m
Flame atomic absorption spectrometry (FAAS) PL-PB-28 issue 04 of 20.08.2019
101 Sewage sludge Metal content
Pb (2,5 –5000) mg/kg Cu (2,5 –5000) mg/kg Cd (0,10 – 100) mg/kg Zn (2,5 – 10000) mg/kg Cr (2,5 – 5000) mg/kg Ni (2,5 – 5000) mg/kg
Inductively coupled plasma mass spectrometry (ICP-MS) PN-EN 16171:2017-02
102 Sewage sludge Mercury content
Range (0,013 – 33) mg/kg
Cold vapour atomic absorption spectrometry (CVAAS) PN-EN 16175-1:2017-02
103 Sewage sludge Calcium content
Range (0,40 – 30)% Magnesium content Range (0,10 – 1,00)%
Flame atomic absorption spectrometry (FAAS) PN-EN ISO 7980:2002 | PN-EN 16173:2012
104 Waste: code 19 05 99 Total organic carbon (TOC) content
Range (3,2 – 20) %
Spectrometry method in the infrared range IR PN-EN 15936:2022-07 excluding Method A
105 Waste: code 19 05 03, 19 05 99 Mercury content
Range (0,013 – 33) mg/kg
Cold vapour atomic absorption spectrometry (CVAAS) PN-EN 16175-1:2017-02
106 Waste: code 19 05 03, 19 05 99 Metal content
Pb (2,5 – 400) mg/kg Cu (2,5 – 400) mg/kg Cd (0,10 – 100) mg/kg Zn (2,5 – 4000) mg/kg Cr (2,5 – 400) mg/kg Ni (2,5 – 400) mg/kg
Inductively coupled plasma mass spectrometry (ICP-MS) PN-EN 16171:2017-02
107 Water Mercury concentration
Range (0,50 – 10) μg/l
Hydride generation atomic absorption spectrometry (HGAAS) PN-EN ISO 12846:2012 excluding cl. 6 + Ap1: 2016-07
108 Water Metal concentrations
Al (5,0 – 250) μg/l Cd (0, 50 – 10) μg/l Cr (2,0 – 50) μg/l Cu (0,0050 – 0,50) mg/l Pb (2,0 – 100) μg/l Ni (5,0 – 250) μg/l Mn (5,0 – 250) μg/l Ag (0,0010 – 0,050) mg/l
Electrothermal atomization atomic absorption spectrometry (ETAAS) PN-EN ISO 15586:2005
109 Water Zinc concentration
Range (0,40 – 1,50) mg/l
Flame atomic absorption spectrometry (FAAS) PN-ISO 8288:2002 Method A
110 Water Sodium concentration
Range (0,10 – 250) mg/l
Flame atomic absorption spectrometry (FAAS) PN-ISO 9964-1:1994 + Ak:1997+Ap1:2009
111 Water Potassium concentration
Range (0,10 – 150) mg/l
Flame atomic absorption spectrometry (FAAS) PN-ISO 9964-2:1994 + Ak:1997
112 Water Magnesium concentration
Range (0,10 – 50) mg/l
Flame atomic absorption spectrometry (FAAS) PN-EN ISO 7980:2002
113 Water Bromate concentration
Range (3,0 – 100) μg/l
Ion chromatography with conductometric detection (IC-CD) PL-PB-25 issue 05 of 11.09.2025
114 Water Anion concentrations
Nitrites (0,050 – 1,0) mg/l Chlorides (1,5 – 250) mg/l Bromides (0,050 – 1,0) mg/l Fluorides (0,050 – 8,0 ) mg/l Phosphates (0,10 – 2,0) mg/l Sulfates (2,5 – 250) mg/l
Ion chromatography with conductometric detection (IC-CD) PN-EN ISO 10304-1:2009 + AC:2012
115 Water Anion concentrations
Chlorites (0,010 – 0,50) mg/l Chlorates (0,025 – 0,50) mg/l
Ion chromatography with conductometric detection (IC-CD) PN-EN ISO 10304-4:2022-08
116 Water Sum of chlorates and chlorites (calculated) PL-PB-25 issue 05 of 11.09.2025
117 Water Concentration of polycyclic aromatic hydrocarbons (PAH)
benzo(a)pyrene (0,0020 – 0,10) μg/l fluoranthene (0,0020 – 0,10) μg/l benzo(b)fluoranthene Range (0,0020 – 0,10) μg/l benzo(k)fluoranthene (0,0020 – 0,10) μg/l benzo(ghi)perylene (0,0020 – 0,10) μg/l indeno (1,2,3-c,d)pyrene (0,0020 – 0,10) μg/l Sum of PAH: (benzo(b)fluoranthene, benzo(k)fluoranthene, benzo(g,h,i)perylene, indeno (1,2,3-cd)pyrene) (calculated)
Gas chromatography with mass spectrometry detection (GC-MS) PL-PB-24 issue 03 of 03.06.2019
118 Water Element concentration
Arsenic (2,0 – 100) μg/l Selenium (2,0 – 100) μg/l Antimony (1,0 – 20) μg/l Boron (0,08 – 4,0) mg/l
Inductively coupled plasma mass spectrometry (ICP-MS) PN-EN ISO 17294-2:2024-04
119 Water Concentration of volatile organic compounds
Trichloroethene (0,10 – 10) μg/l Tetrachloroethene (0,10 – 10) μg/l Sum of trichloroethene and tetrachloroethene (calculated) Carbon tetrachloride (0,10 – 10) μg/l
Gas chromatography with electron capture detection (GC-ECD) PN-EN ISO 10301:2002
120 Water Total organic carbon (TOC) concentration
Range (1,40 – 18,6) mg/l
Spectrometry method in the infrared range IR PN-EN 1484:1999
121 Water (including swimming pool water) Concentration of volatile organic compounds
Chloroform (trichloromethane) Range (1,0 – 120) μg/l Dibromochloromethane (1,0 – 120) μg/l Bromodichloromethane (1,0 – 120) μg/l Bromoform (1,0 – 120) μg/l Sum of THM (the above four compounds) (calculated)
Gas chromatography with electron capture detection (GC-ECD) PN-EN ISO 10301:2002
122 Water (including swimming pool water) Anion concentrations
Nitrates (0,50 – 50) mg/l
Ion chromatography with conductometric detection (IC-CD) PN-EN ISO 10304-1:2009 + AC:2012
123 Water, wastewater Mineral oil index
Range (0,10 – 100) mg/l
Gas chromatography with flame ionization detection (GC-FID) PN-EN ISO 9377-2:2003
124 Wastewater Zinc concentration
Range (0,40 – 250) mg/l
Flame atomic absorption spectrometry (FAAS) PN-ISO 8288:2002 Method A
125 Wastewater Metal concentrations:
Cd (0,0005 – 0,04) mg/l Cr (0,0020 – 0,20) mg/l Cu (0,0050 – 4,0) mg/l Pb (0,0020 – 0,40) mg/l Ni (0,0050 – 1,0) mg/l
Electrothermal atomization atomic absorption spectrometry (ETAAS) PN-EN ISO 15586:2005
126 Wastewater Mercury concentration
Range (0,0010 – 0,04) mg/l
Hydride generation atomic absorption spectrometry (HGAAS) PN-EN ISO 12846:2012 excluding cl. 6 + Ap1: 2016-07
127 Wastewater Total organic carbon (TOC) concentration
Range (4,30 – 380) mg/l
Spectrometry method in the infrared range IR PN-EN 1484:1999
128 Water Sampling for microbiological testing PN-EN ISO 19458:2007 excluding cl. 4.4.4.2; 4.4.5; 4.4.6
129 Water intended for human consumption Total count of microorganisms at 22 0C Plate method (pour plate) PN-EN ISO 6222:2004
130 Water (including swimming pool water) Total microorganism count at 36 0C Plate method (pour plate) PN-EN ISO 6222:2004
131 Water Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 + A1:2017-04
132 Water (including swimming pool water) Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 + A1:2017-04
133 Water Enterococci (faecal streptococci) count Membrane filtration method PN-EN ISO 7899-2:2004
134 Water (including swimming pool water) Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266:2009
135 Water (including swimming pool water) Count of bacteria of the genus Legionella
Matrix A; Procedure 5; Medium A-BCYE Matrix A; Procedure 7; Medium C-GVPC Matrix B; Procedure 7; Medium C-GVPC
Membrane filtration method PN-EN ISO 11731:2017-08 + Ap1:2019-12
136 Water Most probable number, Escherichia coli MPN method (miniaturized) PN-EN ISO 9308-3:2002
137 Water Most probable number of enterococci (faecal streptococci) MPN method (miniaturized) PN-EN ISO 7899-1:2002
138 Sewage sludge, plant cultivation aids: - soil improvers Presence of bacteria of the genus Salmonella Culture method with biochemical and serological confirmation PL-PB-23 issue 05 of 01.10.2019
139 Sewage sludge Presence and number of viable eggs of intestinal parasites ATT (Ascaris spp., Trichuris spp., Toxocara spp.) Isolation, flotation, incubation and microscopic observation method PN-Z-19005:2018-10

Reference standards (90)

PL-IO-22 issue 01 of 15.01.2017
PL-IO-23 issue 05 of 20.10.2022
PL-PB-05 issue 03 of 15.09.2014
PL-PB-12 issue 02 of 15.05.2014
PL-PB-13 issue 03 of 10.09.2021
PL-PB-17 issue 04 of 16.11.2017
PL-PB-23 issue 05 of 01.10.2019
PL-PB-24 issue 03 of 03.06.2019
PL-PB-25 issue 05 of 11.09.2025
PL-PB-26 issue 04 of 24.11.2020
PL-PB-27 issue 03 of 01.10.2019
PL-PB-28 issue 04 of 20.08.2019
PL-PB-30 issue 06 of 28.10.2025
PN-71/C-04567/02
PN-75/C-04576-15
PN-77/C-04584
PN-77/C-04604/08
PN-78/C-04541
PN-82/C-04576/08
PN-92/C-04590/02
PN-C-04554-4:1999 Annex A
PN-EN 13039:2011
PN-EN 13040:2009
PN-EN 13342:2002
PN-EN 14672:2006
PN-EN 1484:1999
PN-EN 15934:2013-02 excluding Method B
PN-EN 15935:2022-01
PN-EN 15936:2022-07 excluding Method A
PN-EN 16171:2017-02
PN-EN 16173:2012
PN-EN 16175-1:2017-02
PN-EN 1622:2006
PN-EN 1899-2:2002
PN-EN 25663:2001
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10301:2002
PN-EN ISO 10304-1:2009 + AC:2012
PN-EN ISO 10304-4:2022-08
PN-EN ISO 10390:2022-09
PN-EN ISO 10523:2012
PN-EN ISO 11731:2017-08 + Ap1:2019-12
PN-EN ISO 12846:2012 excluding cl. 6 + Ap1: 2016-07
PN-EN ISO 15586:2005
PN-EN ISO 16266:2009
PN-EN ISO 17294-2:2024-04
PN-EN ISO 18412:2007
PN-EN ISO 19458:2007 excluding cl. 4.4.4.2; 4.4.5; 4.4.6
PN-EN ISO 5667-13:2011 excluding cl. 6.3.3, 6.3.4, 6.3.5, 6.3.10
PN-EN ISO 5667-6:2016-12 excluding cl. 7.5, 7.6
PN-EN ISO 5814:2013
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6222:2004
PN-EN ISO 6878:2006 cl. 4 + Ap1:2010+Ap2:2010
PN-EN ISO 6878:2006 cl. 7 + Ap1:2010+Ap2:2010
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7887:2012 cl. 6 + Ap1:2015-06
PN-EN ISO 7887:2012 cl. 7 + Ap1:2015-06
PN-EN ISO 7899-1:2002
PN-EN ISO 7899-2:2004
PN-EN ISO 7980:2002
PN-EN ISO 8467:2001
PN-EN ISO 9308-1:2014-12 + A1:2017-04
PN-EN ISO 9308-3:2002
PN-EN ISO 9377-2:2003
PN-EN ISO 9963-1:2001 cl. 8.2.2 + Ap1:2004
PN-ISO 12579:2013
PN-ISO 15705:2005
PN-ISO 5667-10:2021-11
PN-ISO 5667-11:2017-10 excluding cl. 5.2, 6.2, 6.3
PN-ISO 5667-5:2017-10
PN-ISO 6058:1999
PN-ISO 6059:1999
PN-ISO 6332:2001 + Ap1:2016-06
PN-ISO 7150-1:2002
PN-ISO 8288:2002 Method A
PN-ISO 9280:2002
PN-ISO 9297:1994
PN-ISO 9964-1:1994 + Ak:1997+Ap1:2009
PN-ISO 9964-2:1994 + Ak:1997
PN-R-04020:1994 +Az1:2004
PN-R-04022:1996 +Az1:2002
PN-R-04023:1996
PN-R-04031:1997
PN-Z-19005:2018-10
based on the HACH method No. 8021 and 8167
based on the Hach Lange cuvette test No. 138, No. 238, No. 338
based on the Hach Lange cuvette test No. 315

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/PL/AB%20680