🇵🇱 „EKO-SERWIS” s.c. PL

PCA AB 667 • Łódź, Poland • 201 methods

Water & wastewaterEnvironmentMicrobiology

„EKO-SERWIS” s.c. is a laboratory accredited by PCA under number AB 667 (Łódź, Poland). Its accreditation scope covers 201 test methods in the following areas: Water & wastewater, Environment, Microbiology. Test objects include: Water intended for human consumption, Water, Water, wastewater, Swimming pool water. Most frequently used techniques: Spectrophotometric method, Titrimetric method, Membrane filtration method.

At a glance

  • Accreditation number: PCA AB 667
  • Methods in scope: 201
  • Types of test objects: 19
  • Techniques used: 29
  • City: Łódź, Poland
Accreditation number
AB 667
Accreditation body
PCA
Address
Dorota Markowska, Maciej Markowski, ul. Wierzbowa 48, 90-133 Łódź
City
Łódź, Poland

What this laboratory tests (19)

Analytical techniques used (29)

Certificate information

Issue date
15.10.2026
Issue no.
29

Accreditation scope — test methods (201)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Swimming pool water Sampling for chemical and physical testing PN-ISO 5667-5:2017-10 IS-7 edition 3 of 29.01.2018
2 Bathing water Sampling for microbiological testing PN-EN ISO 19458:2007
3 Water (including swimming pool water) Sampling for microbiological testing PN-EN ISO 19458:2007
4 Water (including swimming pool water) Temperature
Range (0,5 – 90) °C
PN-77/C-04584
5 Groundwater Sampling for chemical and physical testing PN-ISO 5667-11:2017-10
6 Sewage sludge, waste o) code: 19 08 05 02 02 04 Sampling for chemical and physical, microbiological and parasitological testing PN-EN ISO 5667-13:2011 excluding 6.3.5; 6.3.8.5.
7 Waste o) code: 19 08 01 19 08 02 10 12 08 10 12 13 Sampling for chemical and physical testing PN-EN ISO 5667-13:2011 excluding 6.3.4; 6.3.5; 6.3.8
8 Soil Sampling for chemical and physical testing PN-R-04031:1997 | PN-ISO 10381-4:2007
9 Surface water Sampling for chemical and physical testing PN-EN ISO 5667-6:2016-12 excluding cl. 7.6
10 Wastewater (including rainwater and snowmelt water) Sampling for chemical and physical testing Manual method; Automatic method PN-ISO 5667-10:2021-11
11 Wastewater (including rainwater and snowmelt water) Temperature:
Range (0,5 – 50) °C
PN-77/C-04584
12 Water intended for human consumption Sampling for chemical and physical testing (including sensory testing)
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
PN-ISO 5667-5:2017-10
13 Water intended for human consumption Temperature
Range (0,5 – 90) °C
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
PN-77/C-04584
14 Water intended for human consumption Sampling for microbiological testing
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
PN-EN ISO 19458:2007
15 Water intended for human consumption Temperature
Range (0,5 – 90) °C
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
PN-77/C-04584
16 Water intended for human consumption Coliform bacteria count
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
Membrane filtration method PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12 /A1:2017-04
17 Water intended for human consumption Escherichia coli count
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
Membrane filtration method PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12 /A1:2017-04
18 Water intended for human consumption Coliform bacteria count
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
Most probable number method (MPN) PN-EN ISO 9308-2:2014-06
19 Water intended for human consumption Escherichia coli count
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
Most probable number method (MPN) PN-EN ISO 9308-2:2014-06
20 Water intended for human consumption Intestinal enterococci count
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
Membrane filtration method PN-EN ISO 7899-2:2004
21 Water intended for human consumption Intestinal enterococci count
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
Most probable number method (MPN) ENTEROLERT-DW (IDEXX), edition 06-18085-07 of 2019 | PN-EN ISO 7899-3:2025-11
22 Water intended for human consumption Total viable count at 22 °C
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
Plate method (pour plate) PN-EN ISO 6222:2004
23 Water intended for human consumption Total viable count at 36 °C
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
Plate method (pour plate) PN-EN ISO 6222:2004
24 Water intended for human consumption Pseudomonas aeruginosa count
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
Membrane filtration method PN-EN ISO 16266:2009
25 Water intended for human consumption Clostridium perfringens count including spores
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
Membrane filtration method PN-EN ISO 14189:2016-10
26 Water intended for human consumption Count of bacteria of the genus Legionella
Matrix A: Procedure 5 (medium A-BCYE), Procedure 7 (medium C-GVPC)
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
Membrane filtration method PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08 /Ap1:2019-12
27 Water intended for human consumption Count of bacteria of the genus Legionella
Matrix B: Procedure 7(medium C-GVPC)
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
Membrane filtration method PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08 /Ap1:2019-12
28 Water intended for human consumption Count of bacteria of the genus Legionella
Matrix A Procedure 1 (medium A-BCYE, medium B-BCYE+AB)
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
Plate method (spread plate) PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08 /Ap1:2019-12
29 Water intended for human consumption Count of bacteria of the genus Legionella
Matrix B: Procedure 1 (medium C –GVPC)
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
Plate method (spread plate) PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08 /Ap1:2019-12
30 Water intended for human consumption pH
Range 2,0 – 12,0
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
Potentiometric method PN-EN ISO 10523:2012
31 Water intended for human consumption Chloride concentration
Range (5,0 – 1000) mg/l
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
Titrimetric method PN-ISO 9297:1994
32 Water intended for human consumption Sulphate (VI) concentration
Range (10 – 500) mg/l
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
Gravimetric method PN-ISO 9280:2002
33 Water intended for human consumption Nitrate concentration
Range (0,20– 440) mg/l
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
Spectrophotometric method PN-82/C-04576/08
34 Water intended for human consumption Nitrite concentration
Range (0,023 – 6,6) mg/l
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
Spectrophotometric method PN-EN 26777:1999
35 Water intended for human consumption Total iron concentration
Range (0,010 – 20,0) mg/l
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
Spectrophotometric method PN-ISO 6332:2001+Ap1:2016
36 Water intended for human consumption Element concentration
nickel (6,0 – 6000) μg/l copper (3,0 – 2000) μg/l lead (3,0 – 2500) μg/l cadmium (0,40 – 400) μg/l chromium (2,0 – 2000) μg/l arsenic (3,0 – 2500) μg/l
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
Atomic absorption spectrometry with electrochemical atomization (ETAAS) PN-EN-ISO 15586:2005
37 Water intended for human consumption Anion concentrations
bromides (0,5 – 30) mg/l chlorides (1,0 – 2 500) mg/l sulfates (2,0 – 2 500) mg/l nitrates (0,10 – 100) mg/l fluorides (0,10 – 10) mg/l
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
Ion chromatography with conductometric detection (IC–CD) PN-EN ISO 10304-1:2009 +AC:2012
38 Water intended for human consumption Sodium concentration
Range (5,0 – 500) mg/l
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
Flame atomic absorption spectrometry (FAAS) PN-ISO 9964-1:1994+Ap1:2009 | PN-ISO 9964-1/Ak:1997
39 Water intended for human consumption Electrical conductivity
Range (25 – 3000) μS/cm
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
Conductometric method PN-EN 27888:1999
40 Water intended for human consumption Free chlorine concentration
Range (0,05 – 2,0) mg/l
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
Spectrophotometric method PN-EN ISO 7393-2:2018-04
41 Water intended for human consumption Total chlorine concentration
Range (0,05 – 2,0) mg/l
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
Spectrophotometric method PN-EN ISO 7393-2:2018-04
42 Water intended for human consumption Chloramine concentration (calculated)
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
PN-EN ISO 7393-2:2018-04
43 Water intended for human consumption Element concentration
nickel (2,0 – 2000) μg/l copper (0,050 – 2,0) mg/l lead (1,0 – 2500) μg/l cadmium (0,5 – 1000) μg/l chromium (10,0 – 2000) μg/l arsenic (10,0 – 2500) μg/l manganese (5,0 – 2000) μg/l iron (100 – 20000) μg/l boron (100 – 15000) μg/l aluminium (10,0 – 4000) μg/l silver (1,0 – 1000) μg/l magnesium (1000 –200000) μg/l calcium (1000 –200000) μg/l sodium (1000 –200000) μg/l
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN ISO 11885:2009
44 Water intended for human consumption Total hardness (calculated)
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
45 Water intended for human consumption Element concentration
arsenic (1,0 – 15,0) μg/l antimony (1,0 – 15,0) μg/l selenium (1,0 – 15,0) μg/l
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
Hydride generation inductively coupled plasma optical emission spectrometry (HG-ICP-OES) PN-EN ISO 11885:2009
46 Water intended for human consumption Element concentration
Mercury (0,30 – 10,0) μg/l
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
Inductively coupled plasma atomic emission spectrometry with cold vapour generation (CV-ICP-OES) PN-EN ISO 11885:2009
47 Water intended for human consumption Total organic carbon concentration
Range (2,0 – 30,0) mg/l
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
Spectrophotometric method Nanocolor test OWO 30 NEO No. 985048 issue 11.2025
48 Water intended for human consumption Turbidity
Range (0,10 – 100) NTU
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
Nephelometric method PN-EN ISO 7027-1:2016-09
49 Water intended for human consumption Magnesium concentration (calculated)
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
PN-99/C-04554/04 Annex A
50 Water intended for human consumption Total content of calcium and magnesium (total hardness)
Range (7 – 1000) mg/l CaCO3
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
Titrimetric method PN-ISO 6059:1999
51 Water intended for human consumption Aluminium concentration
Range (0,040 – 1,0) mg/l
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
Spectrophotometric method PN-92/C-04605/02
52 Water intended for human consumption Boron concentration
Range (0,50 – 2,0) mg/l
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
Spectrophotometric method PN-75/C-04563.01
53 Water intended for human consumption Permanganate index
Range (0,50 – 10) mg /l O2
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
Titrimetric method PN-EN ISO 8467:2001
54 Water intended for human consumption Ammonium ion concentration
Range (0,030 – 2,6) mg/l
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
Spectrophotometric method PN-ISO 7150-1:2002
55 Water intended for human consumption Manganese concentration
Range (1,5 – 2000) μg/l
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
Atomic absorption spectrometry with electrochemical atomization (ETAAS) PN-EN-ISO 15586:2005
56 Water intended for human consumption Colour
Range (2,0 – 70) mg/l Pt
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
Spectrophotometric method PN-EN ISO 7887:2012+Ap1:2015 Method C
57 Water intended for human consumption Calcium concentration
Range (0,05 – 2,5) mmol/l
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
Titrimetric method PN-ISO 6058:1999
58 Water intended for human consumption Pesticide concentrations:
aldrin (0,007 – 1,0) μg/l dieldrin (0,007 – 1,0) μg/l heptachlor (0,007 – 1,0) μg/l p, p’- DDD (0,007 – 1,0) μg/l p, p’- DDE (0,007 – 1,0) μg/l p, p’- DDT (0,007 – 1,0) μg/l endrin (0,007 – 1,0) μg/l alpha- HCH (0,007 – 1,0) μg/l beta- HCH (0,007 – 1,0) μg/l delta- HCH (0,007 – 1,0) μg/l gamma- HCH (0,007 – 1,0) μg/l alpha-endosulfan (0,007 – 1,0) μg/l beta-endosulfan (0,007 – 1,0) μg/l heptachlor epoxide (0,007 – 1,0) μg/l endrin aldehyde (0,007 – 1,0) μg/l methoxychlor (0,007 – 1,0) μg/l
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
Gas chromatography with electron capture detection (GC-ECD) PN-EN ISO 6468:2002
59 Water intended for human consumption Sum of pesticide concentrations (calculated)
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
60 Water intended for human consumption Trihalomethanes (THM) concentration
trichloromethane (chloroform) (1,5 – 100) μg/l bromodichloromethane (1,5– 100) μg/l dibromochloromethane (1,5 – 100) μg/l tribromomethane (bromoform) (1,5 – 100) μg/l
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
Gas chromatography with electron capture detection (GC-ECD) PN-EN ISO 10301:2002
61 Water intended for human consumption Sum of trihalomethane (THM) concentrations (calculated)
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
62 Water intended for human consumption Chlorate, chlorite concentration
Range (0,075 – 2,0) mg/l
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
By ion chromatography with conductometric detection (IC-CD) PN-EN ISO 10304-4:2022-08
63 Water intended for human consumption Presence of foreign taste
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
Organoleptic method PN-EN 1622:2006 Annex C
64 Water intended for human consumption Taste threshold number TFN
Range 1 – 4
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
Simplified method, paired, non-forced choice PN-EN 1622:2006
65 Water intended for human consumption Presence of foreign odour
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
Organoleptic method PN-EN 1622:2006 Annex C
66 Water intended for human consumption Odour threshold number TON
Range 1 – 4
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
Simplified method, paired, non-forced choice PN-EN 1622:2006
67 Water Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12 /A1:2017-04
68 Water Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12 /A1:2017-04
69 Water Coliform bacteria count Most probable number method (MPN) PN-EN ISO 9308-2:2014-06
70 Water Escherichia coli count Most probable number method (MPN) PN-EN ISO 9308-2:2014-06
71 Water Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004
72 Water Intestinal enterococci count Most probable number method (MPN) PN-EN ISO 7899-3:2025-11
73 Water Total viable count at 22 °C Plate method (pour plate) PN-EN ISO 6222:2004
74 Water Total viable count at 36 °C Plate method (pour plate) PN-EN ISO 6222:2004
75 Water Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266:2009
76 Water Clostridium perfringens count including spores Membrane filtration method PN-EN ISO 14189:2016-10
77 Water (including swimming pool water), Water intended for human consumption Count of coagulase – positive staphylococci Membrane filtration method PN-Z-11001-3:2000
78 Water (including swimming pool water) Count of bacteria of the genus Legionella
Matrix A: Procedure 5 (medium A-BCYE), Procedure 7 (medium C-GVPC)
Membrane filtration method PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08 /Ap1:2019-12
79 Water (including swimming pool water) Count of bacteria of the genus Legionella
Matrix B: Procedure 7(medium C-GVPC)
Membrane filtration method PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08 /Ap1:2019-12
80 Water (including swimming pool water) Count of bacteria of the genus Legionella
Matrix A Procedure 1 (medium A-BCYE, medium B-BCYE+AB)
Plate method (spread plate) PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08 /Ap1:2019-12
81 Water (including swimming pool water) Count of bacteria of the genus Legionella
Matrix B: Procedure 1 (medium C –GVPC)
Plate method (spread plate) PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08 /Ap1:2019-12
82 Swimming pool water Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12 /A1:2017-04
83 Swimming pool water Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12 /A1:2017-04
84 Swimming pool water Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266:2009
85 Swimming pool water Total viable count at 36 °C Plate method (pour plate) PN-EN ISO 6222:2004
86 Bathing water Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12 /A1:2017-04
87 Bathing water Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004
88 Water, bathing water Escherichia coli count Most probable number method (MPN) PN-EN ISO 9308-3:2002
89 Sewage sludge, waste o) code: 19 08 05 Presence of bacteria of the genus Salmonella Culture method with biochemical and serological confirmation PN-EN ISO 6579-1:2017-04 | PN-EN ISO 6579-1:2017-04/A1:2020- 09
90 Sewage sludge, waste o) code: 19 08 05 Presence and count of viable eggs of intestinal parasites Ascaris sp., Toxocara sp., Trichuris sp.
Range from 1 ATT/kg of dry matter
Flotation method, microscopic PN-Z-19005:2018
91 Water, wastewater pH
Range 2,0 – 12,0
Potentiometric method PN-EN ISO 10523:2012
92 Water, wastewater Total suspended solids (TSS)
Range (2,0 – 2000) mg/l
Gravimetric method PN-EN 872:2007+Ap1:2007
93 Water, wastewater Dry residue
Range (10 – 2000) mg/l
Gravimetric method PN-78/C-04541
94 Water, wastewater Dissolved solids concentration
Range (10 – 1000) mg/l
Gravimetric method PN-EN 15216:2022-03
95 Water, wastewater Chloride concentration
Range (5,0 – 1000) mg/l
Titrimetric method PN-ISO 9297:1994
96 Water, wastewater Sulphate (VI) concentration
Range (10 – 500) mg/l
Gravimetric method PN-ISO 9280:2002
97 Water, wastewater Kjeldahl nitrogen concentration
Range (0,50 – 250) mg/l
Titrimetric method PN-EN 25663:2001
98 Water, wastewater Dissolved oxygen concentration
Range (0,5 – 15,0) mg/l O2
Electrochemical method PN-EN ISO 5814:2013-04E
99 Water, wastewater Ammonium nitrogen concentration
Range (0,20 – 250) mg/l
Titrimetric method PN-ISO 5664:2002
100 Water, wastewater Nitrate nitrogen concentration
Range (0,050 – 100) mg/l
Spectrophotometric method PN-82/C-04576/08
101 Water, wastewater Nitrite nitrogen concentration
Range (0,007 – 2,0) mg/l
Spectrophotometric method PN-EN 26777:1999
102 Water, wastewater Total nitrogen concentration (calculated) PN-73/C-04576/14
103 Water, wastewater Metal concentrations
zinc (0,10 – 4,0) mg/l
Flame atomic absorption spectrometry (FAAS) PN ISO 8288:2002 Method A
104 Water, wastewater Chemical oxygen demand - COD-Cr
Range (10 – 9000) mg/l O2
Spectrophotometric method PN-ISO 15705:2005
105 Water, wastewater Dissolved oxygen concentration
Range (0,5 – 15,0) mg/l O2
Titrimetric method PN-EN 25813:1997
106 Water, wastewater Mineral oil index
Range (0,10 – 50) mg/l
Gas chromatography with flame ionization detection (GC-FID) PN-EN ISO 9377-2:2003
107 Water, wastewater Phenol index
Range (0,005 – 0,10) mg/l
Spectrophotometric method PN-ISO 6439:1994 Method B
108 Water, wastewater Total iron concentration
Range (0,010 – 20,0) mg/l
Spectrophotometric method PN-ISO 6332:2001+Ap1:2016
109 Water, wastewater Element concentration
nickel (6,0 – 6000) μg/l copper (3,0 – 2000) μg/l lead (3,0 – 2500) μg/l cadmium (0,40 – 400) μg/l total chromium (2,0 – 2000) μg/l arsenic (3,0 – 2500) μg/l
Atomic absorption spectrometry with electrochemical atomization (ETAAS) PN-EN-ISO 15586:2005
110 Water, wastewater Anion concentrations
bromides (0,5 – 30) mg/l chlorides (1,0 – 2 500) mg/l sulfates (2,0 – 2 500) mg/l nitrates (0,10 – 100) mg/l fluorides (0,10 – 10) mg/l
Ion chromatography with conductometric detection (IC–CD) PN-EN ISO 10304-1:2009 +AC:2012
111 Water, wastewater Biochemical oxygen demand - BOD5
Range (1 – 6000) mg/l O2
Electrochemical method; Optical method PN-EN ISO 5815-1:2019-12
112 Water, wastewater Biochemical oxygen demand - BOD5
Range (0,60 – 7,0) mg/l O2
Electrochemical method PN-EN 1899-2:2002
113 Water, wastewater Orthophosphate concentration
Range (0,040 – 50,0) mg/l
Spectrophotometric method PN-EN ISO 6878:2006 +Ap1:2010 +Ap2:2010 cl. 4
114 Water, wastewater Total phosphorus concentration
Range (0,040 – 50,0) mg/l
Spectrophotometric method PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010
115 Water, wastewater Sodium concentration
Range (5,0 – 500) mg/l
Flame atomic absorption spectrometry (FAAS) PN-ISO 9964-1:1994+Ap1:2009 | PN-ISO 9964-1/Ak:1997
116 Water, wastewater Free cyanide concentration
Range (0,03 – 0,6) mg/l
Spectrophotometric method HACH test No. LCK 315 edition 2 of 08.2025
117 Water, wastewater Electrical conductivity
Range (25 – 3000) μS/cm
Conductometric method PN-EN 27888:1999
118 Water, wastewater Free chlorine concentration
Range (0,05 – 2,0) mg/l
Spectrophotometric method PN-EN ISO 7393-2:2018-04
119 Water, wastewater Total chlorine concentration
Range (0,05 – 2,0) mg/l
Spectrophotometric method PN-EN ISO 7393-2:2018-04
120 Water, wastewater Combined chlorine concentration (calculated) PN-EN ISO 7393-2:2018-04
121 Water, wastewater Chloramine concentration (calculated) PN-EN ISO 7393-2:2018-04
122 Water, wastewater Element concentration
nickel (0,0020 – 2,0) mg/l copper (0,050 – 2,0) mg/l lead (0,0010 – 2,5) mg/l cadmium (0,0005 – 1,0) mg/l chromium (0,010 – 2,0) mg/l arsenic (0,010 – 2,5) mg/l manganese (0,0050 – 2,0) mg/l iron (0,010 – 20) mg/l zinc (0,100 – 10,0) mg/l boron (0,100 – 15,0) mg/l aluminium (0,010 – 4,0) mg/l tin (0,020 – 4,0) mg/l antimony (0,050 – 1,0) mg/l barium (0,0010 – 4,0) mg/l molybdenum (0,030 – 2,0) mg/l mercury (0,005 – 0,250) mg/l selenium ( 0,010 – 2,0) mg/l silver (0,0010 – 1,0) mg/l vanadium (0,050 – 4,0) mg/l titanium (0,050 – 2,0) mg/l beryllium (0,100 – 2,0) mg/l cobalt (0,050 – 2,0) mg/l magnesium (1,0 – 200) mg/l calcium (1,0 – 200) mg/l sodium (1,0 – 200) mg/l potassium (1,0 – 200) mg/l phosphorus (0,010 – 50,0) mg/l
Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN ISO 11885:2009
123 Water, wastewater Total hardness (calculated)
124 Water Element concentration
arsenic (1,0 – 15,0) μg/l antimony (1,0 – 15,0) μg/l selenium (1,0 – 15,0) μg/l
Hydride generation inductively coupled plasma optical emission spectrometry (HG-ICP-OES) PN-EN ISO 11885:2009
125 Water Element concentration
Mercury (0,30 – 10,0) μg/l
Inductively coupled plasma atomic emission spectrometry with cold vapour generation (CV-ICP-OES) PN-EN ISO 11885:2009
126 Water Total organic carbon concentration
Range (2,0 – 30,0) mg/l
Spectrophotometric method Nanocolor test OWO 30 NEO No. 985048 issue 11.2025
127 Water Total chlorine concentration
Range (0,05 – 2,0) mg/l
Spectrophotometric method PN-EN ISO 7393-2:2018-04
128 Rainwater and snowmelt water Total suspended solids (TSS)
Range (2,0 – 2000) mg/l
Gravimetric method PN-EN 872:2007+Ap1:2007
129 Rainwater and snowmelt water Mineral oil index
Range (0,10 – 50) mg/l
Gas chromatography with flame ionization detection (GC-FID) PN-EN ISO 9377-2:2003
130 Wastewater Anionic surfactant concentration.
Range (0,050 – 20) mg/l
Spectrophotometric method PN-EN 903:2002
131 Wastewater Concentration of substances extractable with petroleum ether.
Range (10 – 200) mg/l
Gravimetric method PS-3 edition 4 of 22.02.2013
132 Wastewater Chromium(VI) concentration
Range (0,010 – 1,0) mg/l
Spectrophotometric method PN-77/C-04604/08
133 Wastewater Non-ionic surfactant concentration
Range (0,20 – 100) mg/l
Spectrophotometric method PN-ISO 7875-2:2002
134 Water Turbidity
Range (0,10 – 100) NTU
Nephelometric method PN-EN ISO 7027-1:2016-09
135 Water Magnesium concentration (calculated) PN-99/C-04554/04 Annex A
136 Water Total content of calcium and magnesium (total hardness)
Range (7 – 1000) mg/l CaCO3
Titrimetric method PN-ISO 6059:1999
137 Water Total alkalinity
Range (0,40 – 20) mmol/l
Titrimetric method PN-EN ISO 9963-1:2001+Ap1:2004
138 Water Bicarbonate concentration (calculated) PN-EN ISO 9963-1:2001+Ap1:2004
139 Water Carbonate hardness PN-EN ISO 9963-1:2001+Ap1:2004
140 Water Non-carbonate hardness (calculated) PN-ISO 6059:1999
141 Water Chromium(VI) concentration
Range (0,005 – 0,050) mg/l
Spectrophotometric method PN-EN ISO 18724:2026-04
142 Water Aluminium concentration
Range (0,040 – 1,0) mg/l
Spectrophotometric method PN-92/C-04605/02
143 Water Boron concentration
Range (0,50 – 2,0) mg/l
Spectrophotometric method PN-75/C-04563.01
144 Water Permanganate index
Range (0,50 – 10) mg /l O2
Titrimetric method PN-EN ISO 8467:2001
145 Water Ammonium ion concentration
Range (0,030 – 2,6) mg/l
Spectrophotometric method PN-ISO 7150-1:2002
146 Water Presence of foreign taste Qualitative method PN-EN 1622:2006 Annex C
147 Water Taste threshold number TFN
Range 1 – 4
Simplified method, paired, non-forced choice PN-EN 1622:2006
148 Water Presence of foreign odour Qualitative method PN-EN 1622:2006 Annex C
149 Water Odour threshold number TON
Range 1 – 4
Simplified method, paired, non-forced choice PN-EN 1622:2006
150 Water Manganese concentration
Range (1,5 – 2000) μg/l
Atomic absorption spectrometry with electrochemical atomization (ETAAS) PN-EN-ISO 15586:2005
151 Water Colour
Range (2,0 – 70) mg/l Pt
Spectrophotometric method PN-EN ISO 7887:2012+Ap1:2015 Method C
152 Water Calcium concentration
Range (0,05 – 2,5) mmol/l
Titrimetric method PN-ISO 6058:1999
153 Water Pesticide concentrations:
aldrin (0,007 – 1,0) μg/l dieldrin (0,007 – 1,0) μg/l heptachlor (0,007 – 1,0) μg/l p, p’- DDD (0,007 – 1,0) μg/l p, p’- DDE (0,007 – 1,0) μg/l p, p’- DDT (0,007 – 1,0) μg/l endrin (0,007 – 1,0) μg/l alpha- HCH (0,007 – 1,0) μg/l beta- HCH (0,007 – 1,0) μg/l delta- HCH (0,007 – 1,0) μg/l gamma- HCH (0,007 – 1,0) μg/l alpha-endosulfan (0,007 – 1,0) μg/l beta-endosulfan (0,007 – 1,0) μg/l heptachlor epoxide (0,007 – 1,0) μg/l endrin aldehyde (0,007 – 1,0) μg/l methoxychlor (0,007 – 1,0) μg/l
Gas chromatography with electron capture detection (GC-ECD) PN-EN ISO 6468:2002
154 Water Sum of pesticide concentrations (calculated)
155 Water Trihalomethanes (THM) concentration
trichloromethane (chloroform) (1,5 – 100) μg/l bromodichloromethane (1,5 – 100) μg/l dibromochloromethane (1,5 – 100) μg/l tribromomethane (bromoform) (1,5 – 100) μg/l
Gas chromatography with electron capture detection (GC-ECD) PN-EN ISO 10301:2002
156 Water Sum of trihalomethane (THM) concentrations (calculated)
157 Water Chlorate, chlorite concentration
Range (0,075 – 2,0) mg/l
By ion chromatography with conductometric detection (IC-CD) PN-EN ISO 10304-4:2022-08
158 Water Sum of chlorates, chlorites (calculated)
159 Swimming pool water Free chlorine concentration
Range (0,05 – 2,0) mg/l
Spectrophotometric method PN-EN ISO 7393-2:2018-04
160 Swimming pool water Total chlorine concentration
Range (0,05 – 2,0) mg/l
Spectrophotometric method PN-EN ISO 7393-2:2018-04
161 Swimming pool water Combined chlorine concentration (calculated) PN-EN ISO 7393-2:2018-04
162 Swimming pool water Permanganate index
Range (0,50 – 10) mg/l O2
Titrimetric method PN-EN ISO 8467:2001
163 Swimming pool water Anion concentrations
nitrates (0,10 – 100) mg/l
Ion chromatography with conductometric detection (IC-CD) PN-EN ISO 10304-1:2009+AC:2012
164 Swimming pool water Turbidity
Range (0,10 – 100) NTU
Nephelometric method PN-EN ISO 7027-1:2016-09
165 Swimming pool water Aluminium concentration
Range (0,040 – 1,0) mg/l
Spectrophotometric method PN-92/C-04605/02
166 Swimming pool water pH
Range 2,0 – 12,0
Potentiometric method PN-EN ISO 10523:2012
167 Swimming pool water Oxidation-reduction (redox) potential vs. Ag/AgCl 3,5 mol/l KCl
Range (220 – 1000) mV
Potentiometric method PS-16 edition 1 of 05.07.2016
168 Swimming pool water Trihalomethanes (THM) concentration
trichloromethane (chloroform) (1,5 – 100) μg/l bromodichloromethane (1,5– 100) μg/l dibromochloromethane (1,5 – 100) μg/l tribromomethane (bromoform) (1,5 – 100) μg/l
Gas chromatography with electron capture detection (GC-ECD) PN-EN ISO 10301:2002
169 Swimming pool water Sum of trihalomethane (THM) concentrations (calculated)
170 Soil pH – in KCl, pH – in CaCl2, pH – in H2O
Range 2,0 – 12,0
Potentiometric method PN-EN ISO 10390:2022-09
171 Soil Dry matter / water content
Range (1,0 – 99,0) %
Gravimetric method PN-EN ISO 11465:2026-03
172 Soil Element content
chromium (1,0 – 5000) mg/kg zinc (10 – 10000) mg/kg lead (0,1 – 5000) mg/kg cadmium (0,05 – 50) mg/kg nickel (0,2 – 5000) mg/kg copper (5,0 – 5000) mg/kg mercury (0,5 – 50) mg/kg
Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN ISO 22036:2024-07
173 Soil Available phosphorus content
Range (1,0 – 50) mg/100g P2O5
Spectrophotometric method PN-R-04023:1996
174 Sewage sludge pH – in KCl, pH – in CaCl2, pH – in H2O
Range 4,0 – 12,0
Potentiometric method PN-EN ISO 10390:2022-09
175 Sewage sludge Loss on ignition of dry matter (LOI) / Residue on ignition
Range (1,0 – 99,0) %
Gravimetric method PN-EN 15935:2022-01
176 Sewage sludge Dry matter / water content
Range (1,0 – 99,0) %
Gravimetric method PN-EN ISO 11465:2026-03
177 Sewage sludge Kjeldahl nitrogen content
Range (0,20 – 7,0) %
Titrimetric method PN-EN 13342:2002
178 Sewage sludge Ammonium nitrogen content
Range (0,10 – 100) g/kg
Titrimetric method PN-EN 14671:2007 | PN-ISO 5664:2002
179 Sewage sludge Total phosphorus content
Range (0,50 – 8,0) %
Spectrophotometric method PN-EN 14672:2006 | PN-EN ISO 6878:2006 +Ap1:2010 +Ap2:2010
180 Sewage sludge Calcium content
Range (0,10 – 15) %
Titrimetric method PS-11 edition 3 of 22.02.2013
181 Sewage sludge Magnesium content
Range (0,080 – 1,5) %
Titrimetric method PS-11 edition 3 of 22.02.2013
182 Sewage sludge Element content
chromium (1,0 – 5000) mg/kg zinc (10 – 10000) mg/kg lead (0,1 – 5000) mg/kg cadmium (0,05 – 50) mg/kg nickel (0,2 – 5000) mg/kg copper (5,0 – 5000) mg/kg mercury (0,5 – 50) mg/kg phosphorus (1,0 – 5000) mg/kg magnesium (100 – 15 000) mg/kg Range (0,010 – 1,50) % calcium (100 –150 000) mg/kg (0,010– 15,0) %
Inductively coupled plasma optical emission spectrometry (ICP–OES) PN-EN ISO 22036:2024-07
183 Waste o) code: 19 08 05 Sampling for chemical and physical, microbiological and parasitological testing
Regulated area: Tests performed for the purposes of the regulated area covered by the Regulation of the Minister of the Environment of 6 February 2015 on municipal sewage sludge (Journal of Laws 2015, item 257) o) waste codes according to the Regulation of the Minister of Climate on the waste catalogue
PN-EN ISO 5667-13:2011 excluding 6.3.5, 6.3.8.5
184 Waste o) code: 19 08 05 pH – in KCl, pH – in CaCl2, pH – in H2O
Range 4,0 – 12,0
Regulated area: Tests performed for the purposes of the regulated area covered by the Regulation of the Minister of the Environment of 6 February 2015 on municipal sewage sludge (Journal of Laws 2015, item 257) o) waste codes according to the Regulation of the Minister of Climate on the waste catalogue
Potentiometric method PN-EN ISO 10390:2022-09
185 Waste o) code: 19 08 05 Loss on ignition of dry matter (LOI)/ Residue on ignition
Range (1,0 – 99,0) %
Regulated area: Tests performed for the purposes of the regulated area covered by the Regulation of the Minister of the Environment of 6 February 2015 on municipal sewage sludge (Journal of Laws 2015, item 257) o) waste codes according to the Regulation of the Minister of Climate on the waste catalogue
Gravimetric method PN-EN 15935:2022-01
186 Waste o) code: 19 08 05 Dry matter / water content
Range (1,0 – 99,0) %
Regulated area: Tests performed for the purposes of the regulated area covered by the Regulation of the Minister of the Environment of 6 February 2015 on municipal sewage sludge (Journal of Laws 2015, item 257) o) waste codes according to the Regulation of the Minister of Climate on the waste catalogue
Gravimetric method PN-EN ISO 11465:2026-03
187 Waste o) code: 19 08 05 Kjeldahl nitrogen content
Range (0,20 – 7,0) %
Regulated area: Tests performed for the purposes of the regulated area covered by the Regulation of the Minister of the Environment of 6 February 2015 on municipal sewage sludge (Journal of Laws 2015, item 257) o) waste codes according to the Regulation of the Minister of Climate on the waste catalogue
Titrimetric method PN-EN 13342:2002
188 Waste o) code: 19 08 05 Ammonium nitrogen content
Range (0,10 – 100) g/kg
Regulated area: Tests performed for the purposes of the regulated area covered by the Regulation of the Minister of the Environment of 6 February 2015 on municipal sewage sludge (Journal of Laws 2015, item 257) o) waste codes according to the Regulation of the Minister of Climate on the waste catalogue
Titrimetric method PN-EN 14671:2007 | PN-ISO 5664:2002
189 Waste o) code: 19 08 05 Total phosphorus content
Range (0,50 – 8,0) %
Regulated area: Tests performed for the purposes of the regulated area covered by the Regulation of the Minister of the Environment of 6 February 2015 on municipal sewage sludge (Journal of Laws 2015, item 257) o) waste codes according to the Regulation of the Minister of Climate on the waste catalogue
Spectrophotometric method PN-EN 14672:2006 | PN-EN ISO 6878:2006 +Ap1:2010 +Ap2:2010
190 Waste o) code: 19 08 05 Calcium content
Range (0,10 – 15) %
Regulated area: Tests performed for the purposes of the regulated area covered by the Regulation of the Minister of the Environment of 6 February 2015 on municipal sewage sludge (Journal of Laws 2015, item 257) o) waste codes according to the Regulation of the Minister of Climate on the waste catalogue
Titrimetric method PS-11 edition 3 of 22.02.2013
191 Waste o) code: 19 08 05 Magnesium content
Range (0,080 – 1,5) %
Regulated area: Tests performed for the purposes of the regulated area covered by the Regulation of the Minister of the Environment of 6 February 2015 on municipal sewage sludge (Journal of Laws 2015, item 257) o) waste codes according to the Regulation of the Minister of Climate on the waste catalogue
Titrimetric method PS-11 edition 3 of 22.02.2013
192 Waste o) code: 19 08 05 Element content
chromium (1,0 – 5000) mg/kg zinc (10 – 10000) mg/kg lead (0,1 – 5000) mg/kg cadmium (0,05 – 50) mg/kg nickel (0,2 – 5000) mg/kg copper (5,0 – 5000) mg/kg mercury (0,5 – 50) mg/kg phosphorus (1,0 – 5000) mg/kg magnesium (100 – 15 000) mg/kg Range (0,010 – 1,50) % calcium (100 – 150 000) mg/kg (0,010– 15,0) %
Regulated area: Tests performed for the purposes of the regulated area covered by the Regulation of the Minister of the Environment of 6 February 2015 on municipal sewage sludge (Journal of Laws 2015, item 257) o) waste codes according to the Regulation of the Minister of Climate on the waste catalogue
Inductively coupled plasma optical emission spectrometry (ICP–OES) PN-EN ISO 22036:2024-07
193 Waste o) code: 19 08 05 Presence and count of viable eggs of intestinal parasites Ascaris sp., Toxocara sp., Trichuris sp.
Range from 1 ATT/kg of dry matter
Regulated area: Tests performed for the purposes of the regulated area covered by the Regulation of the Minister of the Environment of 6 February 2015 on municipal sewage sludge (Journal of Laws 2015, item 257) o) waste codes according to the Regulation of the Minister of Climate on the waste catalogue
Flotation method, microscopic PN-Z-19005:2018
194 Waste o) code: 19 08 05 Presence of bacteria of the genus Salmonella
Regulated area: Tests performed for the purposes of the regulated area covered by the Regulation of the Minister of the Environment of 6 February 2015 on municipal sewage sludge (Journal of Laws 2015, item 257) o) waste codes according to the Regulation of the Minister of Climate on the waste catalogue
Culture method with biochemical and serological confirmation PN-EN ISO 6579-1:2017-04 | PN-EN ISO 6579-1:2017-04/ A1:2020- 09
195 Waste o) code: 19 08 01 19 08 02 10 12 08 10 12 13 Sampling for chemical and physical testing
Regulated area: Tests performed for the purposes of the regulated area covered by the Regulation of the Minister of Economy of 16 July 2015 on the admission of waste to landfills (Journal of Laws 2015, item 1277) o) waste codes according to the Regulation of the Minister of Climate on the waste catalogue
PN-EN ISO 5667-13:2011 excluding 6.3.4; 6.3.5; 6.3.8
196 Waste o) code: 19 08 01 19 08 02 10 12 08 10 12 13 Total dissolved solids (TDS)
Range (10 – 7500) mg/kg
Regulated area: Tests performed for the purposes of the regulated area covered by the Regulation of the Minister of Economy of 16 July 2015 on the admission of waste to landfills (Journal of Laws 2015, item 1277) o) waste codes according to the Regulation of the Minister of Climate on the waste catalogue
Gravimetric method PN-EN 15216:2022-03 | PN-EN 12457-4:2006
197 Waste o) code: 19 08 01 19 08 02 10 12 08 10 12 13 Sulfate content
Range (100 – 2500) mg/kg
Regulated area: Tests performed for the purposes of the regulated area covered by the Regulation of the Minister of Economy of 16 July 2015 on the admission of waste to landfills (Journal of Laws 2015, item 1277) o) waste codes according to the Regulation of the Minister of Climate on the waste catalogue
Gravimetric method PN-ISO 9280:2002 | PN-EN 12457-4:2006
198 Waste o) code: 19 08 01 19 08 02 10 12 08 10 12 13 Chloride content
Range (50 – 10000) mg/kg
Regulated area: Tests performed for the purposes of the regulated area covered by the Regulation of the Minister of Economy of 16 July 2015 on the admission of waste to landfills (Journal of Laws 2015, item 1277) o) waste codes according to the Regulation of the Minister of Climate on the waste catalogue
Titrimetric method PN-ISO 9297:1994 | PN-EN 12457-4:2006
199 Waste o) code: 19 08 01 19 08 02 10 12 08 10 12 13 Anion content
sulfates (100 – 2500) mg/kg chlorides (10 – 10000) mg/kg fluorides (1,0 – 100) mg/kg
Regulated area: Tests performed for the purposes of the regulated area covered by the Regulation of the Minister of Economy of 16 July 2015 on the admission of waste to landfills (Journal of Laws 2015, item 1277) o) waste codes according to the Regulation of the Minister of Climate on the waste catalogue
Ion chromatography with conductometric detection (IC–CD) PN-EN ISO 10304-1:2009+AC:2012 | PN-EN 12457-4:2006
200 Waste o) code: 19 08 01 19 08 02 10 12 08 10 12 13 Element content
nickel (0,020 – 20,0) mg/kg copper (0,50 – 20,0) mg/kg lead (0,010 – 25,0) mg/kg cadmium (0,0050 – 10,0) mg/kg chromium (0,050 – 20,0) mg/kg arsenic (0,10 – 20,0) mg/kg zinc (1,00 – 100) mg/kg barium (0,010 – 40,0) mg/kg molybdenum (0,30 – 20,0) mg/kg selenium (0,10 – 20,0) mg/kg
Regulated area: Tests performed for the purposes of the regulated area covered by the Regulation of the Minister of Economy of 16 July 2015 on the admission of waste to landfills (Journal of Laws 2015, item 1277) o) waste codes according to the Regulation of the Minister of Climate on the waste catalogue
Inductively coupled plasma optical emission spectrometry (ICP–OES) PN-EN ISO 11885:2009 | PN-EN 12457-4:2006
201 Waste o) code: 19 08 01 19 08 02 10 12 08 10 12 13 Element content
mercury (0,0040- 0,10) mg/kg antimony (0,010 – 0,15) mg/kg
Regulated area: Tests performed for the purposes of the regulated area covered by the Regulation of the Minister of Economy of 16 July 2015 on the admission of waste to landfills (Journal of Laws 2015, item 1277) o) waste codes according to the Regulation of the Minister of Climate on the waste catalogue
Hydride generation inductively coupled plasma optical emission spectrometry (HG-ICP-OES) PN-EN ISO 11885:2009 | PN-EN 12457-4:2006

Reference standards (93)

ENTEROLERT-DW (IDEXX), edition 06-18085-07 of 2019
PN ISO 8288:2002 Method A
PN-73/C-04576/14
PN-75/C-04563.01
PN-77/C-04584
PN-77/C-04604/08
PN-78/C-04541
PN-82/C-04576/08
PN-92/C-04605/02
PN-99/C-04554/04 Annex A
PN-EN 12457-4:2006
PN-EN 13342:2002
PN-EN 14671:2007
PN-EN 14672:2006
PN-EN 15216:2022-03
PN-EN 15935:2022-01
PN-EN 1622:2006
PN-EN 1622:2006 Annex C
PN-EN 1899-2:2002
PN-EN 25663:2001
PN-EN 25813:1997
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN 903:2002
PN-EN ISO 10301:2002
PN-EN ISO 10304-1:2009 +AC:2012
PN-EN ISO 10304-1:2009+AC:2012
PN-EN ISO 10304-4:2022-08
PN-EN ISO 10390:2022-09
PN-EN ISO 10523:2012
PN-EN ISO 11465:2026-03
PN-EN ISO 11731:2017-08
PN-EN ISO 11731:2017-08 /Ap1:2019-12
PN-EN ISO 11885:2009
PN-EN ISO 14189:2016-10
PN-EN ISO 16266:2009
PN-EN ISO 18724:2026-04
PN-EN ISO 19458:2007
PN-EN ISO 22036:2024-07
PN-EN ISO 5667-13:2011 excluding 6.3.4; 6.3.5; 6.3.8
PN-EN ISO 5667-13:2011 excluding 6.3.5, 6.3.8.5
PN-EN ISO 5667-13:2011 excluding 6.3.5; 6.3.8.5.
PN-EN ISO 5667-6:2016-12 excluding cl. 7.6
PN-EN ISO 5814:2013-04E
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6222:2004
PN-EN ISO 6468:2002
PN-EN ISO 6579-1:2017-04
PN-EN ISO 6579-1:2017-04/ A1:2020- 09
PN-EN ISO 6579-1:2017-04/A1:2020- 09
PN-EN ISO 6878:2006 +Ap1:2010 +Ap2:2010
PN-EN ISO 6878:2006 +Ap1:2010 +Ap2:2010 cl. 4
PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7393-2:2018-04
PN-EN ISO 7887:2012+Ap1:2015 Method C
PN-EN ISO 7899-2:2004
PN-EN ISO 7899-3:2025-11
PN-EN ISO 8467:2001
PN-EN ISO 9308-1:2014-12
PN-EN ISO 9308-1:2014-12 /A1:2017-04
PN-EN ISO 9308-2:2014-06
PN-EN ISO 9308-3:2002
PN-EN ISO 9377-2:2003
PN-EN ISO 9963-1:2001+Ap1:2004
PN-EN-ISO 15586:2005
PN-ISO 10381-4:2007
PN-ISO 15705:2005
PN-ISO 5664:2002
PN-ISO 5667-10:2021-11
PN-ISO 5667-11:2017-10
PN-ISO 5667-5:2017-10
PN-ISO 5667-5:2017-10 IS-7 edition 3 of 29.01.2018
PN-ISO 6058:1999
PN-ISO 6059:1999
PN-ISO 6332:2001+Ap1:2016
PN-ISO 6439:1994 Method B
PN-ISO 7150-1:2002
PN-ISO 7875-2:2002
PN-ISO 9280:2002
PN-ISO 9297:1994
PN-ISO 9964-1/Ak:1997
PN-ISO 9964-1:1994+Ap1:2009
PN-R-04023:1996
PN-R-04031:1997
PN-Z-11001-3:2000
PN-Z-19005:2018
PS-11 edition 3 of 22.02.2013
PS-16 edition 1 of 05.07.2016
PS-3 edition 4 of 22.02.2013
HACH test No. LCK 315 edition 2 of 08.2025
Nanocolor test OWO 30 NEO No. 985048 issue 11.2025

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/PL/AB%20667