🇵🇱 INSTYTUT ŁĄCZNOŚCI PL

PCA AB 666 • Warszawa, Poland • 33 methods

AutomotiveEnvironment

INSTYTUT ŁĄCZNOŚCI is a laboratory accredited by PCA under number AB 666 (Warszawa, Poland). Its accreditation scope covers 33 test methods in the following areas: Automotive, Environment. Test objects include: Household appliances, audiovisual equipment, audio-video equipment,…, Transmitting antennas and antenna units of television, radio broadc…, Coaxial cables for feeding various types of transmitting antennas, Environment – electromagnetic field in the vicinity of radiocommuni…. Most frequently used techniques: Measurement method: direct, Direct measurement method.

At a glance

  • Accreditation number: PCA AB 666
  • Methods in scope: 33
  • Types of test objects: 9
  • Techniques used: 2
  • City: Warszawa, Poland
Accreditation number
AB 666
Accreditation body
PCA
Address
PAŃSTWOWY INSTYTUT BADAWCZY, ul. Szachowa 1, 04-894 Warszawa, ZAKŁAD KOMPATYBILNOŚCI ELEKTROMAGNETYCZNEJ, LABORATORIUM BADAŃ EMC
City
Warszawa, Poland

What this laboratory tests (9)

Analytical techniques used (2)

Laboratory locations

Certificate information

Issue date
08.06.2026
Issue no.
21

Accreditation scope — test methods (33)

No. Test object Methodology / Parameters Technique Reference document
Electromagnetic Compatibility and Radio Networks Department; EMC Testing Laboratory
1 Household appliances, audiovisual equipment, audio-video equipment, TV receivers, telecommunications terminal equipment, industrial equipment, industrial accessories, automotive accessories, automotive equipment, industrial equipment in IN SITU testing, machine tools, welding machines, temperature control and regulation equipment, ISM equipment (industrial, medical, scientific), lighting equipment, information technology and telecommunications equipment, in particular terminal equipment as well as military equipment and rail rolling stock equipment Radiated disturbance emission
Range 9 kHz – 26,5 GHz
Measurement method: direct PN-EN 55011:2016-05 | PN-EN 55011:2016-05/A1:2017-06 | PN-EN 55011:2016-05/A2:2021-08 | PN-EN 55012:2012 | PN-EN IEC 55014-1:2021-08 | PN-EN 55022:2011 | PN-EN 55025:2017-04 | NO-06-A500:2012 | PN-EN 55016-2-3:2017-06 | PN-EN 55016-2-3:2017-06/A1:2020-01 | PN-EN 55016-2-3:2017-06/A2:2024-03 | PN-EN 60601-1-2:2015-11 | PN-EN 60601-1-2:2015-11/A1:2021-07 | PN-E-05118:1977 | PN-E-05118:1977/Az1:2008 | PN-EN 50121-2:2017-06 | PN-EN 50121-3-1:2017-05 | PN-EN 50121-3-1:2017-05/A1:2019-07 | PN-EN 50561-1:2013-12 | PN-EN 55032:2015-09 | PN-EN 55032:2015-09/A1:2021-05
2 Household appliances, audiovisual equipment, audio-video equipment, TV receivers, telecommunications terminal equipment, industrial equipment, industrial accessories, automotive accessories, automotive equipment, industrial equipment in IN SITU testing, machine tools, welding machines, temperature control and regulation equipment, ISM equipment (industrial, medical, scientific), lighting equipment, information technology and telecommunications equipment, in particular terminal equipment as well as military equipment and rail rolling stock equipment Emission of conducted disturbances – disturbance voltages
Range 9 kHz – 30 MHz
Measurement method: direct PN-EN 55011:2016-05 | PN-EN 55011:2016-05/A1:2017-06 | PN-EN 55011:2016-05/A2:2021-08 | PN-EN IEC 55014-1:2021-08 | PN-EN 55022:2011 | PN-EN 55025:2017-04 | NO-06-A500:2012 | PN-EN 55016-2-1:2014-09 | PN-EN 55016-2-1:2014-09/A1:2017-12 | PN-EN 60601-1-2:2015-11 | PN-EN 60601-1-2:2015-11/A1:2021-07 | PN-EN 50121-2:2017-06 | PN-EN 50121-3-2:2017-04 | PN-EN 50121-3-2:2017-04/A1:2019-07 | PN-EN 50561-1:2013-12 | PN-EN 55032:2015-09 | PN-EN 55032:2015-09/A1:2021-05
3 Household appliances, audiovisual equipment, audio-video equipment, TV receivers, telecommunications terminal equipment, industrial equipment, industrial accessories, automotive accessories, automotive equipment, industrial equipment in IN SITU testing, machine tools, welding machines, temperature control and regulation equipment, ISM equipment (industrial, medical, scientific), lighting equipment, information technology and telecommunications equipment, in particular terminal equipment as well as military equipment and rail rolling stock equipment Emission of conducted disturbances – disturbance power Measurement method: direct PN-EN IEC 55014-1:2021-08 | PN-EN 55016-2-2:2011
4 Household appliances, audiovisual equipment, audio-video equipment, TV receivers, telecommunications terminal equipment, industrial equipment, industrial accessories, automotive accessories, automotive equipment, industrial equipment in IN SITU testing, machine tools, welding machines, temperature control and regulation equipment, ISM equipment (industrial, medical, scientific), lighting equipment, information technology and telecommunications equipment, in particular terminal equipment as well as military equipment and rail rolling stock equipment Emission of conducted disturbances – voltage fluctuations and flicker of the supply voltage Measurement method: direct PN-EN 61000-3-3:2013-10 | PN-EN 61000-3-3:2013-10/A1:2019-10 | PN-EN 61000-3-3:2013-10/A2:2022-04 | PN-EN IEC 61000-3-11:2020-01
5 Household appliances, audiovisual equipment, audio-video equipment, TV receivers, telecommunications terminal equipment, industrial equipment, industrial accessories, automotive accessories, automotive equipment, industrial equipment in IN SITU testing, machine tools, welding machines, temperature control and regulation equipment, ISM equipment (industrial, medical, scientific), lighting equipment, information technology and telecommunications equipment, in particular terminal equipment as well as military equipment and rail rolling stock equipment Immunity to electrostatic discharge (ESD)
Range up to 30 kV
PN-EN 61000-4-2:2011 | PN-EN 60601-1-2:2015-11 | PN-EN 60601-1-2:2015-11/A1:2021-07 | PN-EN 55035:2017-09
6 Household appliances, audiovisual equipment, audio-video equipment, TV receivers, telecommunications terminal equipment, industrial equipment, industrial accessories, automotive accessories, automotive equipment, industrial equipment in IN SITU testing, machine tools, welding machines, temperature control and regulation equipment, ISM equipment (industrial, medical, scientific), lighting equipment, information technology and telecommunications equipment, in particular terminal equipment as well as military equipment and rail rolling stock equipment Immunity to radio-frequency electromagnetic fields
Range (20 – 6000) MHz
PN-EN 61000-4-3:2021-06 | NO-06-A500:2012 | PN-EN 60601-1-2:2015-11 | PN-EN 60601-1-2:2015-11/A1:2021-07 | PN-EN 61000-4-20:2011 | PN-EN 55016-2-4:2005 | PN-EN 55035:2017-09
7 Household appliances, audiovisual equipment, audio-video equipment, TV receivers, telecommunications terminal equipment, industrial equipment, industrial accessories, automotive accessories, automotive equipment, industrial equipment in IN SITU testing, machine tools, welding machines, temperature control and regulation equipment, ISM equipment (industrial, medical, scientific), lighting equipment, information technology and telecommunications equipment, in particular terminal equipment as well as military equipment and rail rolling stock equipment Immunity to radio fields in close proximity
Range 9 kHz – 150 kHz Range 150 kHz – 26 MHz
PN-EN 61000-4-39:2017-07 | PN-EN 60601-1-2:2015-11 | PN-EN 60601-1-2:2015-11/A1:2021-07
8 Household appliances, audiovisual equipment, audio-video equipment, TV receivers, telecommunications terminal equipment, industrial equipment, industrial accessories, automotive accessories, automotive equipment, industrial equipment in IN SITU testing, machine tools, welding machines, temperature control and regulation equipment, ISM equipment (industrial, medical, scientific), lighting equipment, information technology and telecommunications equipment, in particular terminal equipment as well as military equipment and rail rolling stock equipment Immunity to fast transients
Range up to 5,5 kV
PN-EN 61000-4-4:2013-05 | PN-EN 60601-1-2:2015-11 | PN-EN 60601-1-2:2015-11/A1:2021-07 | PN-EN 55035:2017-09
9 Household appliances, audiovisual equipment, audio-video equipment, TV receivers, telecommunications terminal equipment, industrial equipment, industrial accessories, automotive accessories, automotive equipment, industrial equipment in IN SITU testing, machine tools, welding machines, temperature control and regulation equipment, ISM equipment (industrial, medical, scientific), lighting equipment, information technology and telecommunications equipment, in particular terminal equipment as well as military equipment and rail rolling stock equipment Immunity to surges
Range up to 5 kV
PN-EN 61000-4-5:2014-10 | PN-EN 61000-4-5:2014-10/A1:2018-01 | PN-EN 60601-1-2:2015-1 | PN-EN 60601-1-2:2015-11/A1:2021-07 | PN-EN 55035:2017-09
10 Household appliances, audiovisual equipment, audio-video equipment, TV receivers, telecommunications terminal equipment, industrial equipment, industrial accessories, automotive accessories, automotive equipment, industrial equipment in IN SITU testing, machine tools, welding machines, temperature control and regulation equipment, ISM equipment (industrial, medical, scientific), lighting equipment, information technology and telecommunications equipment, in particular terminal equipment as well as military equipment and rail rolling stock equipment Immunity to conducted disturbances induced by radio-frequency fields
Range (0,15 – 80) MHz
PN-EN IEC 61000-4-6:2024-03 | PN-EN 60601-1-2:2015-11 | PN-EN 60601-1-2:2015-11/A1:2021-07 | PN-EN 55016-2-4:2005 | NO-06-A500:2012 | PN-EN 55035:2017-09
11 Household appliances, audiovisual equipment, audio-video equipment, TV receivers, telecommunications terminal equipment, industrial equipment, industrial accessories, automotive accessories, automotive equipment, industrial equipment in IN SITU testing, machine tools, welding machines, temperature control and regulation equipment, ISM equipment (industrial, medical, scientific), lighting equipment, information technology and telecommunications equipment, in particular terminal equipment as well as military equipment and rail rolling stock equipment Immunity to voltage dips and power supply interruptions
Range up to 16 A (single-phase and DC)
PN-EN IEC 61000-4-11:2020-11 | PN-EN 61000-4-29:2004 | PN-EN 60601-1-2:2015-11 | PN-EN 60601-1-2:2015-11/A1:2021-07 | PN-EN 55035:2017-09
12 Household appliances, audiovisual equipment, audio-video equipment, TV receivers, telecommunications terminal equipment, industrial equipment, industrial accessories, automotive accessories, automotive equipment, industrial equipment in IN SITU testing, machine tools, welding machines, temperature control and regulation equipment, ISM equipment (industrial, medical, scientific), lighting equipment, information technology and telecommunications equipment, in particular terminal equipment as well as military equipment and rail rolling stock equipment Immunity to power-frequency magnetic field
Range up to 100 A/m
PN-EN 61000-4-8:2010 | PN-EN 55035:2017-09
13 Household appliances, audiovisual equipment, audio-video equipment, TV receivers, telecommunications terminal equipment, industrial equipment, industrial accessories, automotive accessories, automotive equipment, industrial equipment in IN SITU testing, machine tools, welding machines, temperature control and regulation equipment, ISM equipment (industrial, medical, scientific), lighting equipment, information technology and telecommunications equipment, in particular terminal equipment as well as military equipment and rail rolling stock equipment Immunity to damped oscillatory wave PN-EN IEC 61000-4-18:2019-08
14 Household appliances, audiovisual equipment, audio-video equipment, TV receivers, telecommunications terminal equipment, industrial equipment, industrial accessories, automotive accessories, automotive equipment, industrial equipment in IN SITU testing, machine tools, welding machines, temperature control and regulation equipment, ISM equipment (industrial, medical, scientific), lighting equipment, information technology and telecommunications equipment, in particular terminal equipment as well as military equipment and rail rolling stock equipment Immunity to damped sinusoidal wave PN-EN 61000-4-12:2017-12
15 Power lines and substations Power quality
Range for 50 Hz mains, single-phase and three-phase, configurations: delta, star and others within the measuring capabilities of the instrument Single-phase supply voltage (58 – 400) V Three-phase supply voltage (100 – 693) V Supply current up to 16A
Measurement method: direct PN-EN 61000-4-30:2015-05
16 Household appliances, audiovisual equipment, audio-video equipment, TV receivers, telecommunications terminal equipment, industrial equipment, industrial accessories, automotive accessories, automotive equipment, industrial equipment in IN SITU testing, machine tools, welding machines, temperature control and regulation equipment, ISM equipment (industrial, medical, scientific), lighting equipment, information technology and telecommunications equipment, in particular terminal equipment as well as military equipment and rail rolling stock equipment Emission of harmonics into the supply network (single-phase and three-phase equipment)
Range (0,1 – 100) %
Measurement method: direct PN-EN 61000-3-2:2019-04 | PN-EN 61000-3-2:2019-04/A1:2021-08 | PN-EN 61000-3-2:2019-04/A2:2024-12 | PN-EN 61000-4-7:2007 | PN-EN 61000-4-7:2007/A1:2011 | PN-EN 61000-3-12:2012 | PN-EN 61000-3-12:2012/A1:2024-11
17 Shielded cabins and other shielded enclosures Shielding effectiveness
Range (10 – 18 000 000) kHz
Measurement method: direct NO-06-A501:2009 +A1:2018
18 Test sites for radiated emission measurements NSA factor / Field distribution (VSWR)
Range (30 – 1000) MHz / (1 – 18) GHz
PN-EN 55016-1-4:2019:04 | PN-EN 55016-1-4:2019:04/A1:2021-03 | PN-EN 55016-1-4:2019:04/A2:2024-01
19 Transmitting antennas and antenna units of television, radio broadcasting and radiocommunication antenna systems, professional and general-purpose receiving antennas Radiation characteristics
Range (30 MHz – 18 GHz)
Measurement method: direct PN-T-84712-2:1996
20 Transmitting antennas and antenna units of television, radio broadcasting and radiocommunication antenna systems, professional and general-purpose receiving antennas Energy gain
Range (30 MHz – 18 GHz)
Measurement method: direct PN-T-84712-3:1996
21 Transmitting antennas and antenna units of television, radio broadcasting and radiocommunication antenna systems, professional and general-purpose receiving antennas Standing wave ratio SWR
Range (30 MHz –18 GHz)
Measurement method: direct PN-T-84710-02:1984
22 Transmitting antennas and antenna units of television, radio broadcasting and radiocommunication antenna systems, professional and general-purpose receiving antennas Front-to-back radiation ratio
Range (30 MHz – 18 GHz)
Measurement method: direct PN-T-84710-01:1984
23 Transmitting antennas and antenna units of television, radio broadcasting and radiocommunication antenna systems, professional and general-purpose receiving antennas Antenna immunity to orthogonal polarisation
Range (30 MHz – 18 GHz)
Measurement method: direct PN-T-84710-02:1984
24 Coaxial cables for feeding various types of transmitting antennas Attenuation per unit length
Range (9 kHz – 8,5 GHz)
Measurement method: direct IEC 1196-1:1995
25 Coaxial cables for feeding various types of transmitting antennas Standing wave ratio
Range (9 kHz – 8,5 GHz)
Measurement method: direct IEC 1196-1:1995
26 Coaxial cables for feeding various types of transmitting antennas Shortening factor
Range (9 kHz – 8,5 GHz)
Measurement method: direct IEC 1196-1:1995
27 Environment – electromagnetic field in the vicinity of radiocommunication installations: broadband measurements Electric field strength in the frequency range: 27MHz – 60 GHz
Range 1 V/m – 350 V/m
Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the legally regulated area; The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Direct measurement method Annex to the Regulation of the Minister of Climate of 17.02.2020 (consolidated text Journal of Laws 2022, item 2630)
28 Environment – electromagnetic field in the vicinity of radiocommunication installations: broadband measurements Magnetic field strength in the frequency range: 3 kHz – 3 MHz
Range 0,5 A/m – 100 A/m
Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the legally regulated area; The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Direct measurement method Annex to the Regulation of the Minister of Climate of 17.02.2020 (consolidated text Journal of Laws 2022, item 2630)
29 Environment – electromagnetic field in the vicinity of radiocommunication installations: broadband measurements Magnetic field strength in the frequency range: 27MHz – 60 GHZ (calculated)
Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the legally regulated area; The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Clause 3 of the Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630)
30 Environment – electromagnetic field in the vicinity of radiocommunication installations: selective measurements Electric field strength in the frequency range: 27 MHz – 6 GHz
Range 0,1 V/m – 200 V/m
Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the legally regulated area; The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Direct measurement method Annex to the Regulation of the Minister of Climate of 17.02.2020 (consolidated text Journal of Laws 2022, item 2630)
31 Environment – electromagnetic field in the vicinity of radiocommunication installations: selective measurements Magnetic field strength in the frequency range: 27 MHz – 6 GHz (calculated)
Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the legally regulated area; The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Clause 3 of the Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630)
32 Workplace environment – electromagnetic fields originating from transmitting devices of radiocommunication systems (base stations of mobile telephony systems) Electric field strength in the frequency range: 800 MHz – 60 GHz
Range 1 V/m – 350 V/m
Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the regulated area; The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (consolidated text: Journal of Laws of 2018, item 331)
Direct measurement method Principles and Methods of Assessing the Working Environment 2017, No. 2 (92), pp. 89–131
33 Workplace environment – electromagnetic fields originating from transmitting devices of radiocommunication systems (base stations of mobile telephony systems) Magnetic field strength in the frequency range: 800 MHz – 60 GHz (calculated)
Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the regulated area; The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (consolidated text: Journal of Laws of 2018, item 331)
Principles and Methods of Assessing the Working Environment 2017, No. 2 (92), pp. 89–131

Reference standards (66)

IEC 1196-1:1995
NO-06-A500:2012
NO-06-A501:2009 +A1:2018
PN-E-05118:1977
PN-E-05118:1977/Az1:2008
PN-EN 50121-2:2017-06
PN-EN 50121-3-1:2017-05
PN-EN 50121-3-1:2017-05/A1:2019-07
PN-EN 50121-3-2:2017-04
PN-EN 50121-3-2:2017-04/A1:2019-07
PN-EN 50561-1:2013-12
PN-EN 55011:2016-05
PN-EN 55011:2016-05/A1:2017-06
PN-EN 55011:2016-05/A2:2021-08
PN-EN 55012:2012
PN-EN 55016-1-4:2019:04
PN-EN 55016-1-4:2019:04/A1:2021-03
PN-EN 55016-1-4:2019:04/A2:2024-01
PN-EN 55016-2-1:2014-09
PN-EN 55016-2-1:2014-09/A1:2017-12
PN-EN 55016-2-2:2011
PN-EN 55016-2-3:2017-06
PN-EN 55016-2-3:2017-06/A1:2020-01
PN-EN 55016-2-3:2017-06/A2:2024-03
PN-EN 55016-2-4:2005
PN-EN 55022:2011
PN-EN 55025:2017-04
PN-EN 55032:2015-09
PN-EN 55032:2015-09/A1:2021-05
PN-EN 55035:2017-09
PN-EN 60601-1-2:2015-1
PN-EN 60601-1-2:2015-11
PN-EN 60601-1-2:2015-11/A1:2021-07
PN-EN 61000-3-12:2012
PN-EN 61000-3-12:2012/A1:2024-11
PN-EN 61000-3-2:2019-04
PN-EN 61000-3-2:2019-04/A1:2021-08
PN-EN 61000-3-2:2019-04/A2:2024-12
PN-EN 61000-3-3:2013-10
PN-EN 61000-3-3:2013-10/A1:2019-10
PN-EN 61000-3-3:2013-10/A2:2022-04
PN-EN 61000-4-12:2017-12
PN-EN 61000-4-20:2011
PN-EN 61000-4-29:2004
PN-EN 61000-4-2:2011
PN-EN 61000-4-30:2015-05
PN-EN 61000-4-39:2017-07
PN-EN 61000-4-3:2021-06
PN-EN 61000-4-4:2013-05
PN-EN 61000-4-5:2014-10
PN-EN 61000-4-5:2014-10/A1:2018-01
PN-EN 61000-4-7:2007
PN-EN 61000-4-7:2007/A1:2011
PN-EN 61000-4-8:2010
PN-EN IEC 55014-1:2021-08
PN-EN IEC 61000-3-11:2020-01
PN-EN IEC 61000-4-11:2020-11
PN-EN IEC 61000-4-18:2019-08
PN-EN IEC 61000-4-6:2024-03
PN-T-84710-01:1984
PN-T-84710-02:1984
PN-T-84712-2:1996
PN-T-84712-3:1996
Principles and Methods of Assessing the Working Environment 2017, No. 2 (92), pp. 89–131
Clause 3 of the Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630)
Annex to the Regulation of the Minister of Climate of 17.02.2020 (consolidated text Journal of Laws 2022, item 2630)

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/PL/AB%20666