🇵🇱 LABORATORIUM TECHNIKI BUDOWLANEJ Sp. z o.o. PL
Construction
LABORATORIUM TECHNIKI BUDOWLANEJ Sp. z o.o. is a laboratory accredited by PCA under number AB 661 (Dąbrowa Górnicza, Poland). Its accreditation scope covers 28 test methods in the following areas: Construction. Test objects include: Gates excluding power-operated gates, Width: up to 7000 mm, Height:…, Windows and doors, Width: up to 4000 mm, Height: up to 2500 mm, Windows and doors, Width: up to 7000 mm, Height: up to 4000 mm, Hinged doors. Most frequently used techniques: Calculation method, Pressure difference method.
At a glance
- Accreditation number: PCA AB 661
- Methods in scope: 28
- Types of test objects: 17
- Techniques used: 2
- City: Dąbrowa Górnicza, Poland
- Accreditation number
- AB 661
- Accreditation body
- PCA
- Address
- ul. Laski 83, 41-306 Dąbrowa Górnicza
- City
- Dąbrowa Górnicza, Poland
What this laboratory tests (17)
- Gates excluding power-operated gates, Width: up to 7000 mm, Height: up to 4000 mm — 4 methods
- Windows and doors, Width: up to 4000 mm, Height: up to 2500 mm — 4 methods
- Windows and doors, Width: up to 7000 mm, Height: up to 4000 mm — 3 methods
- Hinged doors — 2 methods
- Single-leaf hinged doors, Width: up to 1350 mm, Height: up to 2550 mm — 2 methods
- Windows — 2 methods
- Curtain walling — 1 method
- Hinged doors, Width: up to 1350 mm, Height: up to 2550 mm — 1 method
- Product(s): Curtain wall kits / as external curtain walls not subject to reaction to fire requirements — 1 method
- Product(s): Doors, windows, shutters, blinds, gates and related building hardware / Doors and gates (with or without related hardware) / other declared specific uses or uses subject to other specific requirements, in particular noise, energy, tightness and safety in use — 1 method
- Product(s): Doors, windows, shutters, blinds, gates and related building hardware / Windows (with or without related hardware) / all other — 1 method
- Roof lights — 1 method
- Sections of window and door frames, their connections with glazing — 1 method
- Side-hung, bottom-hung and tilt-and-turn windows and balcony doors, Width: up to 1350 mm, Height: up to 2550 mm, Weight: up to 150 kg — 1 method
- Unplasticized poly(vinyl chloride) (PVC-U) profiles for the fabrication of windows and doors — 1 method
- and 2 more
Analytical techniques used (2)
- Calculation method — 7 methods
- Pressure difference method — 1 method
Laboratory locations
- LABORATORIUM TECHNIKI BUDOWLANEJ Sp. z o.o. (main site) — ul. Laski 83, 41-306 Dąbrowa Górnicza
- LABORATORIUM TECHNIKI BUDOWLANEJ Sp. z o.o. (BUILDING TECHNOLOGY LABORATORY) — ul. Laski 83, 41-306 Dąbrowa Górnicza
Certificate information
- Issue date
- 23.06.2026
- Issue no.
- 22
Accreditation scope — test methods (28)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Laboratorium Techniki Budowlanej Sp. z o.o. | |||||
| 1 | Windows and doors, Width: up to 7000 mm, Height: up to 4000 mm | Air permeability Range (1,3 - 520) m3/h Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 1026:2016 „N” | ||
| 2 | Windows and doors, Width: up to 7000 mm, Height: up to 4000 mm | Watertightness Range (0 - 3600) Pa Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 1027:2016 „N” | ||
| 3 | Windows and doors, Width: up to 7000 mm, Height: up to 4000 mm | Resistance to wind load Range (-3600 - +3600) Pa Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 12211:2016 „N” | ||
| 4 | Windows and doors | Thermal transmittance Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
Calculation method | PN-EN ISO 10077-1:2017-10 „N” | |
| 5 | Windows and doors, Width: up to 4000 mm, Height: up to 2500 mm | Resistance to static load Range (0 - 15) kN |
PN-EN 1628:2021-11 | ||
| 6 | Windows and doors, Width: up to 4000 mm, Height: up to 2500 mm | Resistance to dynamic load | PN-EN 1629:2021-11 | ||
| 7 | Windows and doors, Width: up to 4000 mm, Height: up to 2500 mm | Resistance to burglary attempts | PN-EN 1630:2021-11 | ||
| 8 | Windows and doors, Width: up to 4000 mm, Height: up to 2500 mm | Resistance to soft and heavy body impact | PN-EN 13049:2024-03 | ||
| 9 | Windows | Resistance to torsion Range (20 - 350) N Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 14609:2006 „N” | ||
| 10 | Windows | Sound insulation | Calculation method | PN-EN 14351-1+A2:2016 Annex B | Procedure LTB PL131 edition 4 issue of 25.03.2019 | |
| 11 | Windows and balcony doors, Width: up to 1350 mm, Height: up to 2550 mm | Operating forces Range (4 - 100) N Range (1 - 10) Nm |
PN-EN 12046-1:2005 | ||
| 12 | Side-hung, bottom-hung and tilt-and-turn windows and balcony doors, Width: up to 1350 mm, Height: up to 2550 mm, Weight: up to 150 kg | Repeated opening and closing | PN-EN 1191:2013-06 | ||
| 13 | Unplasticized poly(vinyl chloride) (PVC-U) profiles for the fabrication of windows and doors | Flexural strength by compression of welded corners and T-joints Range (0 - 20) kN |
PN-EN 514:2018-02 | ||
| 14 | Hinged doors | Static torsional strength Range (200 - 350) N Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 948:2000 „N” | ||
| 15 | Hinged doors | Sound insulation | Calculation method | PN-EN 14351-2:2018 Annex B | Procedure LTB PL 131 edition 4 issue of 25.03.2019 | |
| 16 | Hinged doors, Width: up to 1350 mm, Height: up to 2550 mm | Resistance to vertical load | PN-EN 947:2000 | ||
| 17 | Single-leaf hinged doors, Width: up to 1350 mm, Height: up to 2550 mm | Operating forces Range (4 - 100) N Range (1 - 10) Nm |
PN-EN 12046-2:2001 | ||
| 18 | Single-leaf hinged doors, Width: up to 1350 mm, Height: up to 2550 mm | Repeated opening and closing | PN-EN 1191:2013-06 | ||
| 19 | Sections of window and door frames, their connections with glazing | Thermal transmittance Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
Calculation method | PN-EN ISO 10077-2:2017-10 „N” | |
| 20 | Gates excluding power-operated gates, Width: up to 7000 mm, Height: up to 4000 mm | Air permeability Range (1,3 - 520) m3/h Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 12427:2002 „N” | ||
| 21 | Gates excluding power-operated gates, Width: up to 7000 mm, Height: up to 4000 mm | Resistance to water penetration Range (0 - 3600) Pa Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 12489:2002 „N” | ||
| 22 | Gates excluding power-operated gates, Width: up to 7000 mm, Height: up to 4000 mm | Resistance to wind load Range (-3600 - +3600) Pa Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
Pressure difference method | PN-EN 12444:2002 „N” except cl. 8 | |
| 23 | Gates excluding power-operated gates, Width: up to 7000 mm, Height: up to 4000 mm | Thermal transmittance Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
Calculation method | PN-EN 12428:2013-06 „N” | |
| 24 | Curtain walling | Thermal transmittance Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
Calculation method | PN-EN 12631:2017-10 „N” | Procedure PL 121 edition 10 issue of 07.01.2021 | |
| 25 | Roof lights | Thermal transmittance. | Calculation method | PN-EN 1873:2014-07 | Procedure PL 121 edition 10 issue of 07.01.2021 | |
| 26 | Product(s): Doors, windows, shutters, blinds, gates and related building hardware / Windows (with or without related hardware) / all other | ASSESSMENT OF PERFORMANCE ON THE BASIS OF TESTS AND CALCULATIONS, TABULATED VALUES OR DESCRIPTIVE DOCUMENTATION OF THE CONSTRUCTION PRODUCT (System 3) Commission decision number 99/93/WE Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decision: 99/93/EC; 96/580/EC. The laboratory meets the requirements of Regulation No 305/2011 of 9 March 2011 for the activities provided for a testing laboratory (Annex V, point 2, subpoint 3 of Regulation No 305/2011) in the above scope. |
Harmonised technical specifications: EN 14351-1:2006+A2:2016 | Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011, as amended, laying down harmonised conditions for the marketing of construction products and repealing Council Directive 89/106/EEC (OJ L 88 of 4.4.2011, as amended) | ||
| 27 | Product(s): Doors, windows, shutters, blinds, gates and related building hardware / Doors and gates (with or without related hardware) / other declared specific uses or uses subject to other specific requirements, in particular noise, energy, tightness and safety in use | ASSESSMENT OF PERFORMANCE ON THE BASIS OF TESTS AND CALCULATIONS, TABULATED VALUES OR DESCRIPTIVE DOCUMENTATION OF THE CONSTRUCTION PRODUCT (System 3) Commission decision number 99/93/WE Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decision: 99/93/EC; 96/580/EC. The laboratory meets the requirements of Regulation No 305/2011 of 9 March 2011 for the activities provided for a testing laboratory (Annex V, point 2, subpoint 3 of Regulation No 305/2011) in the above scope. |
Harmonised technical specifications: EN 13241:2003+A2:2016 | Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011, as amended, laying down harmonised conditions for the marketing of construction products and repealing Council Directive 89/106/EEC (OJ L 88 of 4.4.2011, as amended) | ||
| 28 | Product(s): Curtain wall kits / as external curtain walls not subject to reaction to fire requirements | ASSESSMENT OF PERFORMANCE ON THE BASIS OF TESTS AND CALCULATIONS, TABULATED VALUES OR DESCRIPTIVE DOCUMENTATION OF THE CONSTRUCTION PRODUCT (System 3) Commission decision number 96/580/WE Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decision: 99/93/EC; 96/580/EC. The laboratory meets the requirements of Regulation No 305/2011 of 9 March 2011 for the activities provided for a testing laboratory (Annex V, point 2, subpoint 3 of Regulation No 305/2011) in the above scope. |
Harmonised technical specifications: EN 13830:2003 | Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011, as amended, laying down harmonised conditions for the marketing of construction products and repealing Council Directive 89/106/EEC (OJ L 88 of 4.4.2011, as amended) | ||
Reference standards (31)
PN-EN 1026:2016 „N”
PN-EN 1027:2016 „N”
PN-EN 1191:2013-06
PN-EN 12046-1:2005
PN-EN 12046-2:2001
PN-EN 12211:2016 „N”
PN-EN 12427:2002 „N”
PN-EN 12428:2013-06 „N”
PN-EN 12444:2002 „N” except cl. 8
PN-EN 12489:2002 „N”
PN-EN 12631:2017-10 „N”
PN-EN 13049:2024-03
PN-EN 14351-1+A2:2016 Annex B
PN-EN 14351-2:2018 Annex B
PN-EN 14609:2006 „N”
PN-EN 1628:2021-11
PN-EN 1629:2021-11
PN-EN 1630:2021-11
PN-EN 1873:2014-07
PN-EN 514:2018-02
PN-EN 947:2000
PN-EN 948:2000 „N”
PN-EN ISO 10077-1:2017-10 „N”
PN-EN ISO 10077-2:2017-10 „N”
Procedure LTB PL 131 edition 4 issue of 25.03.2019
Procedure LTB PL131 edition 4 issue of 25.03.2019
Procedure PL 121 edition 10 issue of 07.01.2021
Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011, as amended, laying down harmonised conditions for the marketing of construction products and repealing Council Directive 89/106/EEC (OJ L 88 of 4.4.2011, as amended)
Harmonised technical specifications: EN 13241:2003+A2:2016
Harmonised technical specifications: EN 13830:2003