🇵🇱 „ECOLABAD” LABORATORIUM FIZYKO-CHEMICZNE PL
Environment
„ECOLABAD” LABORATORIUM FIZYKO-CHEMICZNE is a laboratory accredited by PCA under number AB 647 (Łódź, Poland). Its accreditation scope covers 107 test methods in the following areas: Environment. Test objects include: Workplace environment - air - air samples collected on activated ca…, Workplace environment - air - air samples collected on filters, Workplace environment - air - air samples collected into absorbing…, Workplace environment - air. Most frequently used techniques: Gas chromatography with flame ionization detection (GC-FID), Spectrophotometric method, Flame atomic absorption spectrometry (FAAS).
At a glance
- Accreditation number: PCA AB 647
- Methods in scope: 107
- Types of test objects: 15
- Techniques used: 10
- City: Łódź, Poland
- Accreditation number
- AB 647
- Accreditation body
- PCA
- Address
- BADANIA I ANALIZY ŚRODOWISKA Sp. z o.o., ul. Henryka Wieniawskiego 40, 93-564 Łódź
- City
- Łódź, Poland
What this laboratory tests (15)
- Workplace environment - air - air samples collected on activated carbon tubes — 35 methods
- Workplace environment - air - air samples collected on filters — 27 methods
- Workplace environment - air - air samples collected into absorbing solution — 17 methods
- Workplace environment - air — 6 methods
- Workplace environment - emergency lighting — 4 methods
- Workplace environment - air samples collected on activated carbon tubes — 2 methods
- Workplace environment - cold microclimate — 2 methods
- Workplace environment - hand-arm vibration — 2 methods
- Workplace environment - hot microclimate — 2 methods
- Workplace environment - indoor electric lighting — 2 methods
- Workplace environment - moderate microclimate — 2 methods
- Workplace environment - noise — 2 methods
- Workplace environment - whole-body vibration — 2 methods
- Workplace environment - air - air samples collected on silica gel tubes — 1 method
- Workplace environment - air samples collected on silica gel tubes — 1 method
Analytical techniques used (10)
- Gas chromatography with flame ionization detection (GC-FID) — 40 methods
- Spectrophotometric method — 20 methods
- Flame atomic absorption spectrometry (FAAS) — 18 methods
- Direct measurement method — 10 methods
- Fourier transform infrared spectrometry (FT- IR) — 2 methods
- Gravimetric method — 2 methods
- Electrochemical method — 1 method
- Personal dosimetry method — 1 method
- Stationary method — 1 method
- Turbidimetric method — 1 method
Laboratory locations
- „ECOLABAD” LABORATORIUM FIZYKO-CHEMICZNE (main site) — ul. Henryka Wieniawskiego 40, 93-564 Łódź
- „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.
Certificate information
- Issue date
- 23.07.2026
- Issue no.
- 24
Accreditation scope — test methods (107)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. | |||||
| 1 | Workplace environment - noise | A-weighted equivalent sound level Maximum A-weighted sound level Range (35,0 - 135,0) dB C-weighted peak sound pressure level Range (58,0 - 138,0) dB |
Direct measurement method | PN-N-01307:1994 | PN-EN ISO 9612:2011 excluding the method covering strategies 2 (cl. 10) and 3 – cl. 11 | |
| 2 | Workplace environment - noise | Noise exposure level referred to: an 8-hour daily working time the average weekly working time (calculated) |
PN-N-01307:1994 | PN-EN ISO 9612:2011 excluding the method covering strategies 2 (cl. 10) and 3 – cl. 11 | ||
| 3 | Workplace environment - indoor electric lighting | Illuminance Range (1 - 10 000) lx |
Direct measurement method | PB-06 issue 3 of 02.06.2025 | |
| 4 | Workplace environment - indoor electric lighting | Illuminance uniformity (calculated) | PB-06 issue 3 of 02.06.2025 | ||
| 5 | Workplace environment - emergency lighting | Illuminance Range (0,5 - 3000) lx |
Direct measurement method | PN-EN 1838:2013-11 excluding cl. 4.2.3, 4.2.4, 4.2.7, 4.3.3, 4.3.4, 4.3.7, 4.3.9, 4.4 and 5 | |
| 6 | Workplace environment - emergency lighting | Ratio of minimum to maximum illuminance (calculated) | PN-EN 1838:2013-11 excluding cl. 4.2.3, 4.2.4, 4.2.7, 4.3.3, 4.3.4, 4.3.7, 4.3.9, 4.4 and 5 | ||
| 7 | Workplace environment - emergency lighting | Closing time Range (5 - 70) s |
Direct measurement method | PN-EN 1838:2013-11 excluding cl. 4.2.3, 4.2.4, 4.2.7, 4.3.3, 4.3.4, 4.3.7, 4.3.9, 4.4 and 5 | |
| 8 | Workplace environment - emergency lighting | Minimum duration of lighting operation Range (5 - 3600) s |
Direct measurement method | PN-EN 1838:2013-11 excluding cl. 4.2.3, 4.2.4, 4.2.7, 4.3.3, 4.3.4, 4.3.7, 4.3.9, 4.4 and 5 | |
| 9 | Workplace environment - whole-body vibration | Frequency-weighted r.m.s. vibration acceleration Range (0,03 - 27,0) m/s2 |
Direct measurement method | PN-EN 14253+A1:2011 | |
| 10 | Workplace environment - whole-body vibration | Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the r.m.s. frequency-corrected vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz), Exposure lasting 30 minutes or less, expressed as the r.m.s. frequency-weighted vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz) (calculated) | PN-EN 14253+A1:2011 | ||
| 11 | Workplace environment - hand-arm vibration | Root-mean-square frequency-weighted vibration accelerations Range (0,2 - 50) m/s2 |
Direct measurement method | PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004+A1:2015 | |
| 12 | Workplace environment - hand-arm vibration | Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the vector sum of the r.m.s. frequency-corrected vibration accelerations determined for three directional components (ahwx, ahwy, ahwz), Exposure lasting 30 minutes or less, expressed as the vector sum of the r.m.s. frequency-weighted vibration accelerations determined for three directional components (ahwx, ahwy, ahwz) (calculated) | PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004+A1:2015 | ||
| 13 | Workplace environment - hot microclimate | Air temperature Range (20,0 - 60,0) °C Natural wet bulb temperature Range (10,0 - 60,0) °C Black globe temperature Range (20,0 - 60,0) °C Air velocity Range (0,15 - 2,0) m/s |
Direct measurement method | PN-EN ISO 7243:2018-01 +Ap2:2020-04 | |
| 14 | Workplace environment - hot microclimate | WBGT index, WBGTeff index (calculated) | PN-EN ISO 7243:2018-01 +Ap2:2020-04 | ||
| 15 | Workplace environment - cold microclimate | Air temperature Range (-30,0 - 10,0) °C Black globe temperature Range (-30,0 - 10,0) °C Air humidity Range (20,0 - 90,0) % Air velocity Range (0,15 - 2,0) m/s |
Direct measurement method | PN-EN ISO 11079:2008 | |
| 16 | Workplace environment - cold microclimate | IREQmin index, IREQneutral index, twc index (calculated) | PN-EN ISO 11079:2008 | ||
| 17 | Workplace environment - moderate microclimate | Air temperature Range (5,0 - 60,0) °C Black globe temperature Range (5,0 - 60,0) °C Humidity Range (20,0 - 90,0) % Air velocity Range (0,15 - 2,0) m/s |
Direct measurement method | PN-EN ISO 7730:2006+Ap2:2016-04 | |
| 18 | Workplace environment - moderate microclimate | PMV index, PPD index (calculated) | PN-EN ISO 7730:2006+Ap2:2016-04 | ||
| 19 | Workplace environment - air | Sampling for the assessment of occupational exposure to: dust agents inhalable fraction respirable fraction inorganic substances, including inhalable fraction respirable fraction thoracic fraction organic substances, including inhalable fraction metals and their compounds, including inhalable fraction respirable fraction asbestos respirable fibres refractory ceramic fibres, refractory ceramic fibres mixed with other man-made mineral fibres man-made mineral fibres, excluding refractory ceramic fibres respirable fibres |
Personal dosimetry method | PN-Z-04008-7:2002 | PN-Z-04008-7:2002+Az1:2004 | |
| 20 | Workplace environment - air | Sampling for the assessment of occupational exposure to: inorganic substances, including inhalable fraction organic substances, including inhalable fraction |
Stationary method | PN-Z-04008-7:2002 | PN-Z-04008-7:2002+Az1:2004 | |
| 21 | Workplace environment - air | Exposure index (calculated) | PN-Z-04008-7:2002 | PN-Z-04008-7:2002+Az1:2004 | ||
| 22 | Workplace environment - air | Concentration of harmful dust agents – inhalable fraction Range (0,09 - 20,4) mg/m3 |
Gravimetric method | PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08 | |
| 23 | Workplace environment - air | Concentration of harmful dust agents – respirable fraction Range (0,07 - 9,3) mg/m3 |
Gravimetric method | PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08 | |
| 24 | Workplace environment - air - air samples collected into absorbing solution | Ammonia concentration/content Range (0,08 - 56) mg/m3 Range (14 - 420) μg in the sample |
Spectrophotometric method | PN-71/Z-04041 | |
| 25 | Workplace environment - air - air samples collected into absorbing solution | Chlorine concentration/content Range (0,002 - 3) mg/m3 Range (0,4 - 540) μg in the sample |
Spectrophotometric method | PN-75/Z-04037/03 | |
| 26 | Workplace environment - air - air samples collected into absorbing solution | Concentration/content of hydrogen cyanide Range (0,075 - 5) mg/m3 Range (0,066 - 4,5) ppm Range (0,3 - 20,0) μg in the sample |
Spectrophotometric method | PN-70/Z-04053 | |
| 27 | Workplace environment - air - air samples collected into absorbing solution | Sulphur dioxide concentration/content Range (0,009 - 10) mg/m3 Range (0,0033 - 3,77) ppm Range (3,2 - 3600) μg in the sample |
Spectrophotometric method | PN-Z-04015-12:1996 | PN-Z-04015-12:1996+Ap1:2001 | |
| 28 | Workplace environment - air - air samples collected into absorbing solution | Carbon monoxide concentration Range (2,1 - 239) mg/m3 Range (1,8 - 206) ppm |
Electrochemical method | PB-05 issue 1 of 01.12.2008 | |
| 29 | Workplace environment - air - air samples collected into absorbing solution | Exposure indices (calculated) | PB-05 issue 1 of 01.12.2008 | ||
| 30 | Workplace environment - air - air samples collected into absorbing solution | Concentration/content of formaldehyde and acrolein Formaldehyde (0,002 - 2) mg/m3 Range (0,3 - 360) μg in the sample Acrylaldehyde (Acrolein) (0,002 - 0,2) mg/m3 (0,00086 - 0,086) ppm (0,3 - 36) μg in the sample |
Spectrophotometric method | PB-02 issue 2 of 01.08.2006 | |
| 31 | Workplace environment - air - air samples collected into absorbing solution | Formaldehyde concentration/content Range (0,011 - 10,7) mg/m3 Range (1,0 - 80) μg in the sample |
Spectrophotometric method | PN-76/Z-04045/02 | |
| 32 | Workplace environment - air - air samples collected into absorbing solution | Concentration/content of phosphoric(V) acid and tetraphosphorus decaoxide Range (0,008 - 4) mg/m3 Range (1,4 - 720) μg in the sample |
Spectrophotometric method | PN-Z-04073-1:2014-08 | |
| 33 | Workplace environment - air - air samples collected into absorbing solution | Iodine concentration/content Range (0,05 - 2) mg/m3 Range (8,0 - 360) μg in the sample |
Spectrophotometric method | PN-Z-04433:2011 | |
| 34 | Workplace environment - air - air samples collected into absorbing solution | Formic acid concentration/content Range (0,08 - 30) mg/m3 Range (20 - 7200) μg in the sample |
Spectrophotometric method | PN-88/Z-04196/02 | |
| 35 | Workplace environment - air - air samples collected into absorbing solution | Hydrogen peroxide concentration/content Range (0,04 - 2,1) mg/m3 Range (0,4 - 9,6) μg in the sample |
Spectrophotometric method | PN-Z-04548:2023-03 | |
| 36 | Workplace environment - air - air samples collected into absorbing solution | Ozone concentration/content Range (0,015 - 0,3) mg/m3 Range (1,05 - 21) μg in the sample |
Spectrophotometric method | PN-Z-04007-2:1994 | |
| 37 | Workplace environment - air - air samples collected into absorbing solution | Hydrogen sulphide concentration/content Range (0,05 - 40) mg/m3 Range (18 - 14400) μg in the sample |
Spectrophotometric method | PN-Z-04015-13:1996 | |
| 38 | Workplace environment - air - air samples collected into absorbing solution | Concentration/content of nitrogen monoxide and nitrogen dioxide nitrogen oxide (0,22 - 23,1) mg/m3 Range (0,176 - 18,55) ppm Range (1,3 - 104) μg in the sample nitrogen dioxide (0,067 - 7,11) mg/m3 (0,035 - 3,72) ppm (0,4 - 16) μg in the sample |
Spectrophotometric method | PN-Z-04009-11:2008 | |
| 39 | Workplace environment - air - air samples collected into absorbing solution | Potassium hydroxide concentration/content Range (0,02 - 2,3) mg/m3 Range (7,3 - 810) μg in the sample |
Spectrophotometric method | PN-87/Z-04005/03 | |
| 40 | Workplace environment - air - air samples collected into absorbing solution | Sodium hydroxide concentration/content Range (0,011 - 2,0) mg/m3 Range (4,3 - 709) μg in the sample |
Spectrophotometric method | PN-84/Z-04005/02 | |
| 41 | Workplace environment - air - air samples collected on filters | Concentration/content of methylenebis (phenyl isocyanate) Range (0,0017 - 0,83) mg/m3 Range (0,62 - 12,5) μg in the sample |
Spectrophotometric method | PN-81/Z-04131/02 | |
| 42 | Workplace environment - air - air samples collected on filters | Concentration/content of barium Range (0,07 - 1,8) mg/m3 Range (53 - 1282) μg in the sample |
Spectrophotometric method | PN-82/Z-04024/02 | |
| 43 | Workplace environment - air - air samples collected on filters | Concentration/content of ammonium chloride – vapours and inhalable fraction Range (0,12 - 40) mg/m3 Range (86 - 28800) μg in the sample |
Spectrophotometric method | PN-Z-04265:2000 | |
| 44 | Workplace environment - air - air samples collected on filters | Concentration/content of chromates (VI) and dichromates (VI) (chromates) (calculated as Cr (VI) Range (0,006 - 0,6) mg/m3 Range (3,9 - 432) μg in the sample |
Spectrophotometric method | PN-87/Z-04126/03 | |
| 45 | Workplace environment - air - air samples collected on filters | Concentration/content of chromium (VI) compounds - calculated as Cr (VI) Range (0,00028 - 0,02) mg/m3 Range (0,192 - 13,4) μg in the sample |
Spectrophotometric method | NIOSH 7600:2015 | |
| 46 | Workplace environment - air - air samples collected on filters | Concentration/content of metallic chromium, chromium compounds: chromium(II), chromium (III),chromium (VI) calculated as Cr. Range (0,029 - 1,17) mg/m3 Range (20,0 - 800) μg in the sample |
Flame atomic absorption spectrometry (FAAS) | PN-Z-04434:2011 | |
| 47 | Workplace environment - air - air samples collected on filters | Concentration of metallic chromium, chromium compounds: chromium (II) - calculated as Cr (II), chromium III – calculated as Cr (III) (calculated) | PB-03 issue 1 of 01.04.2021 | ||
| 48 | Workplace environment - air - air samples collected on filters | Concentration/content of tin and its inorganic compounds, except stannane – calculated as Sn inhalable fraction Range (0,17 - 4,2) mg/m3 Range (125 - 3024) μg in the sample |
Flame atomic absorption spectrometry (FAAS) | PN-Z-04488:2017-10 | |
| 49 | Workplace environment - air - air samples collected on filters | Concentration/content of zinc oxide calculated as Zn inhalable fraction Range (0,003 - 20) mg/m3 Range (2,1 - 14400) μg in the sample |
Flame atomic absorption spectrometry (FAAS) | PN-87/Z-04100/03 | |
| 50 | Workplace environment - air - air samples collected on filters | Concentration/content of cadmium and its inorganic compounds – calculated as Cd inhalable fraction respirable fraction Range (0,0001 - 0,013) mg/m3 Range (0,15 - 15,0) μg in the sample |
Flame atomic absorption spectrometry (FAAS) | PN-Z-04102-3:2013 | |
| 51 | Workplace environment - air - air samples collected on filters | Concentration/content of cobalt and its inorganic compounds – calculated as Co Range (0,002 - 0,4) mg/m3 Range (1,0 - 288) μg in the sample |
Flame atomic absorption spectrometry (FAAS) | PN-Z-04291:2003 | |
| 52 | Workplace environment - air - air samples collected on filters | Concentration/content of manganese and its inorganic compounds - calculated as Mn inhalable fraction respirable fraction Range (0,005 - 0,6) mg/m3 Range (3,6 - 432) μg in the sample |
Flame atomic absorption spectrometry (FAAS) | PN-Z-04472:2015-10+Ap1:2015-12 | |
| 53 | Workplace environment - air - air samples collected on filters | Concentration/content of copper and its inorganic compounds – calculated as Cu Range (0,007 - 0,6) mg/m3 Range (5 - 432) μg in the sample |
Flame atomic absorption spectrometry (FAAS) | PN-Z-04106-3:2002 | |
| 54 | Workplace environment - air - air samples collected on filters | Metallic nickel concentration/content Range (0,015 - 0,58) mg/m3 Range (10,47 - 418,8) μg in the sample |
Flame atomic absorption spectrometry (FAAS) | PN-Z-04502:2019-10 | |
| 55 | Workplace environment - air - air samples collected on filters | Concentration/content of nickel compounds – calculated as Ni inhalable fraction Range (0,0013 - 0,13) mg/m3 Range (0,96 - 96,0) μg in the sample respirable fraction Range (0,00089 - 0,089) mg/m3 Range (0,96 - 96,0) μg in the sample |
Flame atomic absorption spectrometry (FAAS) | PN-Z-04502:2019-10 Principles and Methods of Assessing the Working Environment 2021, No. 4 (110), pp. 179–189 | |
| 56 | Workplace environment - air - air samples collected on filters | Concentration/content of lead and its inorganic compounds – calculated as Pb inhalable fraction Range (0,0035 - 0,142) mg/m3 Range (2,6 - 102) μg in the sample |
Flame atomic absorption spectrometry (FAAS) | PN-Z-04487:2017-10 | |
| 57 | Workplace environment - air - air samples collected on filters | Silver concentration/content. Soluble silver compounds calculated as Ag Range (0,0010 - 0,12) mg/m3 Range (0,75 - 86,40) μg in the sample |
Flame atomic absorption spectrometry (FAAS) | Principles and Methods of Assessing the Working Environment 1998, issue 19 | |
| 58 | Workplace environment - air - air samples collected on filters | Concentration/content of silver – inhalable fraction, insoluble silver compounds – calculated as Ag Range (0,003 - 0,1) mg/m3 Range (2,0 - 72,0) μg in the sample |
Flame atomic absorption spectrometry (FAAS) | PN-Z-04216-2:2012 | |
| 59 | Workplace environment - air - air samples collected on filters | Concentration/content of iron oxides calculated as Fe iron(III) oxide iron(II) oxide triiron tetraoxide – inhalable fraction Range (0,34 - 49,4) mg/m3 Range (49,4 - 7403,8) μg in the sample – respirable fraction Range (0,19 - 44,9) mg/m3 Range (49,4 - 4627,3) μg in the sample |
Flame atomic absorption spectrometry (FAAS) | PN-Z-04469:2025-02 | |
| 60 | Workplace environment - air - air samples collected on filters | Sodium hydroxide concentration/content Range (0,012 - 2) mg/m3 Range (4,5 - 720) μg in the sample |
Flame atomic absorption spectrometry (FAAS) | PN-Z-04435:2011 | |
| 61 | Workplace environment - air - air samples collected on filters | Potassium hydroxide concentration/content Range (0,02 - 7) mg/m3 Range (14 - 215) μg in the sample |
Flame atomic absorption spectrometry (FAAS) | PN-Z-04436:2011 | |
| 62 | Workplace environment - air - air samples collected on filters | Concentration/content of calcium hydroxide inhalable fraction respirable fraction Range (0,06 - 12) mg/m3 Range (46 - 2958) μg in the sample |
Flame atomic absorption spectrometry (FAAS) | PN-Z-04497:2018-09 | |
| 63 | Workplace environment - air - air samples collected on filters | Calcium oxide concentration/content inhalable fraction Range (0,1 - 119,7) mg/m3 Range (71,8 - 3590,9) μg in the sample respirable fraction Range (0,091 - 108,8) mg/m3 Range (71,8 - 3590,9) μg in the sample |
Flame atomic absorption spectrometry (FAAS) | PN-Z-04442:2023-05 | |
| 64 | Workplace environment - air - air samples collected on filters | Concentration/content of calcium carbonate inhalable fraction Range (0,67 - 20,15) mg/m3 Range (498 - 14940) μg in the sample |
Flame atomic absorption spectrometry (FAAS) | PN-Z-04294:2001 | |
| 65 | Workplace environment - air - air samples collected on filters | Concentration/content of highly refined mineral oil – excluding metalworking fluids – inhalable fraction Range (0,3 - 20) mg/m3 Range (0,2 - 14,4) mg in the sample |
Fourier transform infrared spectrometry (FT- IR) | PN-Z-04108-5:2006 | |
| 66 | Workplace environment - air - air samples collected on filters | Concentration/content of crystalline silica (quartz and cristobalite) respirable fraction Range (0,005 - 0,73) mg/m3 Range (5,0 - 500) μg in the sample |
Fourier transform infrared spectrometry (FT- IR) | Principles and Methods of Assessing the Working Environment 2012, No. 4 (74), pp. 117–130 | |
| 67 | Workplace environment - air - air samples collected on filters | Hydrogen chloride concentration/content Range (0,39 - 137) mg/m3 Range (154 - 4110) μg in the sample |
Turbidimetric method | PN-Z-04450:2014-08 | |
| 68 | Workplace environment - air - air samples collected on activated carbon tubes | Acetone concentration/content Range (48 - 3600) mg/m3 Range (0,15 - 3,95) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-89/Z-04023/02 | |
| 69 | Workplace environment - air - air samples collected on activated carbon tubes | Benzene concentration/content Range (0,063 - 3,05) mg/m3 Range (0,019 - 0,94) ppm Range (0,0006 - 0,029) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04016-10:2005 | |
| 70 | Workplace environment - air - air samples collected on activated carbon tubes | Extraction naphtha concentration/content Range (36 - 3000) mg/m3 Range (0,2 - 19,7) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-81/Z-04134/02 | |
| 71 | Workplace environment - air - air samples collected on activated carbon tubes | White spirit concentration/content Range (24 - 1800) mg/m3 Range (0,36 - 20) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-81/Z-04134/03 | |
| 72 | Workplace environment - air - air samples collected on activated carbon tubes | Concentration/content of 2-bromo-2-chloro-1,1,1-trifluoroethane (halothane) Range (0,5 - 200) mg/m3 Range (0,009 - 2,0) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-92/Z-04223/02 | |
| 73 | Workplace environment - air - air samples collected on activated carbon tubes | Concentration/content of butan-1-ol (n-butyl alcohol) Range (4,5 - 300) mg/m3 Range (0,078 - 1,95) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-89/Z-04023/02 | |
| 74 | Workplace environment - air - air samples collected on activated carbon tubes | Concentration/content of butan-2-one Range (44 - 900) mg/m3 Range (0,49 - 9,8) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-79/Z-04107/02 | |
| 75 | Workplace environment - air - air samples collected on activated carbon tubes | 2-butoxyethanol concentration/content Range (8,3 - 400) mg/m3 Range (0,15 - 20) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-89/Z-04023/02 | |
| 76 | Workplace environment - air - air samples collected on activated carbon tubes | Cyclohexane concentration/content Range (30 - 2000) mg/m3 Range (0,38 - 20) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-86/Z-04151/02 | |
| 77 | Workplace environment - air - air samples collected on activated carbon tubes | Cyclohexanone concentration/content Range (4 - 160) mg/m3 Range (0,045 - 2,25) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | Principles and Methods of Assessing the Working Environment 2007, issue 51 | |
| 78 | Workplace environment - air - air samples collected on activated carbon tubes | Dichloromethane concentration/content Range (6,6 - 746) mg/m3 Range (1,87 - 211,7) ppm Range (0,065 - 4,7) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04325:2006 | |
| 79 | Workplace environment - air - air samples collected on activated carbon tubes | Ethanol concentration/content Range (114 - 3800) mg/m3 Range (0,38 - 11,8) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-89/Z-04023/02 | |
| 80 | Workplace environment - air - air samples collected on activated carbon tubes | Concentration/content of diethyl ether Range (26 - 3000) mg/m3 Range (0,35 - 20) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-86/Z-04158/02 | |
| 81 | Workplace environment - air - air samples collected on activated carbon tubes | Ethylbenzene concentration/content Range (8,4 - 700) mg/m3 Range (0,27 - 9,10) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-79/Z-04081/01 | |
| 82 | Workplace environment - air - air samples collected on activated carbon tubes | Ethylene glycol concentration/content Range (1,3 - 100) mg/m3 Range (0,11 - 8) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-88/Z-04203/02 | |
| 83 | Workplace environment - air - air samples collected on activated carbon tubes | Isoflurane concentration/content Range (0,78 - 64) mg/m3 Range (0,056 - 1,2) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04423:2001 | |
| 84 | Workplace environment - air - air samples collected on activated carbon tubes | Concentration/content of xylene – mixture of isomers 1,2-; 1,3-; 1,4- Range (8,5 - 200) mg/m3 Range (0,09 - 17) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-89/Z-04023/02 | PB-14 issue 3 of 10.06.2016 | |
| 85 | Workplace environment - air - air samples collected on activated carbon tubes | Methanol concentration/content Range (10 - 600) mg/m3 Range (0,15 - 3,89) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | Principles and Methods of Assessing the Working Environment 2014, issue 81 | |
| 86 | Workplace environment - air - air samples collected on activated carbon tubes | 1-methoxypropan-2-ol concentration/content Range (13 - 720) mg/m3 Range (0,22 - 20) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04354:2005 | |
| 87 | Workplace environment - air - air samples collected on activated carbon tubes | Kerosene concentration/content Range (7,8 - 600) mg/m3 Range (0,10 - 20) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-92/Z-04227/02 | |
| 88 | Workplace environment - air - air samples collected on activated carbon tubes | Hexane concentration/content - Range (6,3 - 536) mg/m3 Range (0,065 - 3,4) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04136-03:2003 | |
| 89 | Workplace environment - air - air samples collected on activated carbon tubes | 2-butoxyethyl acetate concentration/content Range (9,0 - 600) mg/m3 Range (0,11 - 20) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04304:2003 | |
| 90 | Workplace environment - air - air samples collected on activated carbon tubes | Butyl acetate concentration/content Range (16 - 1900) mg/m3 Range (0,31 - 8,6) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-78/Z-04119/01 | |
| 91 | Workplace environment - air - air samples collected on activated carbon tubes | Ethyl acetate concentration/content Range (17 - 1500) mg/m3 Range (4,65 - 410,3) ppm Range (1,14 - 23) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-78/Z-04119/01 | |
| 92 | Workplace environment - air - air samples collected on activated carbon tubes | Methyl acetate concentration/content Range (23 - 1200) mg/m3 Range (0,35 - 20) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-78/Z-04119/01 | |
| 93 | Workplace environment - air - air samples collected on activated carbon tubes | Concentration/content of propyl acetate Range (19 - 2000) mg/m3 Range (0,22 - 20) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-78/Z-04119/01 | |
| 94 | Workplace environment - air - air samples collected on activated carbon tubes | 2-methoxy-1-methylethyl acetate concentration/content Range (20 - 520) mg/m3 Range (0,36 - 20) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04119-10:2008 | |
| 95 | Workplace environment - air - air samples collected on activated carbon tubes | Vinyl acetate concentration/content Range (1,0 - 60) mg/m3 Range (0,08 - 5,2) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-87/Z-04178/02 | |
| 96 | Workplace environment - air - air samples collected on activated carbon tubes | Pentane concentration/content Range (300 - 6000) mg/m3 Range (0,41 - 20) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04318:2005 | |
| 97 | Workplace environment - air - air samples collected on activated carbon tubes | Concentration/content of propan-1-ol Range (20 - 600) mg/m3 Range (0,20 - 20) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04224-3:2003 | |
| 98 | Workplace environment - air - air samples collected on activated carbon tubes | Propan-2-ol concentration/content Range (49 - 1200) mg/m3 Range (1,14 - 22,7) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-92/Z-04224/02 | |
| 99 | Workplace environment - air - air samples collected on activated carbon tubes | Styrene concentration/content Range (3,7 - 400) mg/m3 Range (0,068 - 20) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-86/Z-04152/02 | |
| 100 | Workplace environment - air - air samples collected on activated carbon tubes | Sevoflurane concentration/content Range (0,29 - 110) mg/m3 Range (0,005 - 2,0) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04429:2011 | |
| 101 | Workplace environment - air - air samples collected on activated carbon tubes | Tetrachloroethene concentration/content Range (4,5 - 428) mg/m3 Range (0,65 - 62,2) ppm Range (0,12 - 20) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-83/Z-04118/02 | |
| 102 | Workplace environment - air - air samples collected on activated carbon tubes | Toluene concentration/content Range (8,3 - 700) mg/m3 Range (0,15 - 5) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-78/Z-04115/01 | |
| 103 | Workplace environment - air - air samples collected on silica gel tubes | Acetic acid concentration/content Range (1,3 - 60) mg/m3 Range (0,52 - 24,1) ppm Range (0,12 - 5) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04323:2004 | |
| 104 | Workplace environment - air | Concentration of chemical substances - acetone (48 - 3600) mg/m3 benzene (0,063 - 3,05) mg/m3 Range (0,019 - 0,94) ppm extraction naphtha (36 - 3000) mg/m3 white spirit (24 - 1800) mg/m3 2-bromo-2-chloro-1,1,1-trifluoroethane (halothane) (0,5 - 200) mg/m3 butan-1-ol (n-butyl alcohol) (4,5 - 300) mg/m3 butan-2-one (44 - 900) mg/m3 2-butoxyethanol (8,3 - 400) mg/m3 cyclohexane (30 - 2000) mg/m3 cyclohexanone (4 - 160) mg/m3 dichloromethane (6,6 - 746) mg/m3 (1,87 - 211,7) ppm ethanol (114 - 3800) mg/m3 diethyl ether (26 - 3000) mg/m3 ethylbenzene (8,4 - 700) mg/m3 ethylene glycol (1,3 - 100) mg/m3 isoflurane (0,78 - 64) mg/m3 acetic acid (1,3 - 60) mg/m3 (0,52 - 24,1) ppm xylene – mixture of isomers 1,2-; 1,3-; 1,4 (8,5 - 200) mg/m3 methanol (10 - 600) mg/m3 1-methoxypropan-2-ol (13 - 720) mg/m3 kerosene (7,8 - 600) mg/m3 n-hexane (6,3 - 536) mg/m3 2-butoxyethyl acetate (9,0 - 600) mg/m3 butyl acetate (16 - 1900) mg/m3 ethyl acetate (17 - 1500) mg/m3 (4,65 - 410,3) ppm methyl acetate (23 - 1200) mg/m3 propyl acetate (19 - 2000) mg/m3 2-methoxy-1-methylethyl acetate (20 - 520) mg/m3 vinyl acetate (1,0 - 60) mg/m3 pentane (300 - 6000) mg/m3 propan-1-ol (20 - 600) mg/m3 propan-2-ol (49 - 1200) mg/m3 styrene (3,7 - 400) mg/m3 sevoflurane (0,29 - 110) mg/m3 tetrachloroethene (4,5 - 428) mg/m3 (0,65 - 62,2) ppm toluene (8,3 - 700) mg/m3 |
Gas chromatography with flame ionization detection (GC-FID) | PB-14 issue 3 of 10.06.2016 | |
| 105 | Workplace environment - air samples collected on activated carbon tubes | Content of chemical substances acetone (0,15 - 3,95) mg in the sample benzene (0,0006 - 0,029) mg in the sample extraction naphtha Range (0,2 - 19,7) mg in the sample white spirit (0,36 - 20) mg in the sample 2-bromo-2-chloro-1,1,1-trifluoroethane (halothane) - (0,009 - 2,0) mg in the sample butan-1-ol (n-butyl alcohol) (0,078 - 1,95) mg in the sample butan-2-one (0,49 - 9,8) mg in the sample 2-butoxyethanol (0,15 - 20) mg in the sample cyclohexane (0,38 - 20) mg in the sample cyclohexanone (0,045 - 2,25) mg in the sample dichloromethane (0,065 - 4,7) mg in the sample ethanol (0,38 - 11,8) mg in the sample diethyl ether (0,35 - 20) mg in the sample ethylbenzene (0,27 - 9,10) mg in the sample ethylene glycol (0,11 - 8,0) mg in the sample isoflurane (0,056 - 1,2) mg in the sample Xylene – mixture of isomers 1,2-; 1,3-; 1,4-(0,09 - 17) mg in the sample methanol (0,15 - 3,89) mg in the sample 1-methoxypropan-2-ol (0,22 - 20) mg in the sample kerosene (0,10 - 20) mg in the sample n-hexane (0,065 - 3,4) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PB-14 issue 3 of 10.06.2016 | |
| 106 | Workplace environment - air samples collected on activated carbon tubes | Content of chemical substances 2-butoxyethyl acetate Range (0,11 - 20) mg in the sample butyl acetate (0,31 - 8,6) mg in sample ethyl acetate (1,14 - 23) mg in sample methyl acetate (0,35 - 20) mg in sample propyl acetate (0,22 - 20) mg in sample 2-methoxy-1-methylethyl acetate – (0,36 - 20) mg in sample vinyl acetate (0,08 - 5,2) mg in sample pentane (0,41 - 20) mg in sample propan-1-ol (0,20 - 20) mg in sample propan-2-ol (1,14 - 22,7) mg in sample sevoflurane (0,005 - 2,0) mg in sample styrene (0,068 - 20) mg in sample toluene (0,15 - 5) mg in sample tetrachloroethene (0,12 - 20) mg in sample |
Gas chromatography with flame ionization detection (GC-FID) | PB-14 issue 3 of 10.06.2016 | |
| 107 | Workplace environment - air samples collected on silica gel tubes | Acetic acid content Range (0,12 - 5) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PB-14 issue 3 of 10.06.2016 | |
Reference standards (91)
NIOSH 7600:2015
PB-02 issue 2 of 01.08.2006
PB-03 issue 1 of 01.04.2021
PB-05 issue 1 of 01.12.2008
PB-06 issue 3 of 02.06.2025
PB-14 issue 3 of 10.06.2016
PN-70/Z-04053
PN-71/Z-04041
PN-75/Z-04037/03
PN-76/Z-04045/02
PN-78/Z-04115/01
PN-78/Z-04119/01
PN-79/Z-04081/01
PN-79/Z-04107/02
PN-81/Z-04131/02
PN-81/Z-04134/02
PN-81/Z-04134/03
PN-82/Z-04024/02
PN-83/Z-04118/02
PN-84/Z-04005/02
PN-86/Z-04151/02
PN-86/Z-04152/02
PN-86/Z-04158/02
PN-87/Z-04005/03
PN-87/Z-04100/03
PN-87/Z-04126/03
PN-87/Z-04178/02
PN-88/Z-04196/02
PN-88/Z-04203/02
PN-89/Z-04023/02
PN-92/Z-04223/02
PN-92/Z-04224/02
PN-92/Z-04227/02
PN-EN 14253+A1:2011
PN-EN 1838:2013-11 excluding cl. 4.2.3, 4.2.4, 4.2.7, 4.3.3, 4.3.4, 4.3.7, 4.3.9, 4.4 and 5
PN-EN ISO 11079:2008
PN-EN ISO 5349-1:2004
PN-EN ISO 5349-2:2004
PN-EN ISO 5349-2:2004+A1:2015
PN-EN ISO 7243:2018-01 +Ap2:2020-04
PN-EN ISO 7730:2006+Ap2:2016-04
PN-EN ISO 9612:2011 excluding the method covering strategies 2 (cl. 10) and 3 – cl. 11
PN-N-01307:1994
PN-Z-04007-2:1994
PN-Z-04008-7:2002
PN-Z-04008-7:2002+Az1:2004
PN-Z-04009-11:2008
PN-Z-04015-12:1996
PN-Z-04015-12:1996+Ap1:2001
PN-Z-04015-13:1996
PN-Z-04016-10:2005
PN-Z-04073-1:2014-08
PN-Z-04102-3:2013
PN-Z-04106-3:2002
PN-Z-04108-5:2006
PN-Z-04119-10:2008
PN-Z-04136-03:2003
PN-Z-04216-2:2012
PN-Z-04224-3:2003
PN-Z-04265:2000
PN-Z-04291:2003
PN-Z-04294:2001
PN-Z-04304:2003
PN-Z-04318:2005
PN-Z-04323:2004
PN-Z-04325:2006
PN-Z-04354:2005
PN-Z-04423:2001
PN-Z-04429:2011
PN-Z-04433:2011
PN-Z-04434:2011
PN-Z-04435:2011
PN-Z-04436:2011
PN-Z-04442:2023-05
PN-Z-04450:2014-08
PN-Z-04469:2025-02
PN-Z-04472:2015-10+Ap1:2015-12
PN-Z-04487:2017-10
PN-Z-04488:2017-10
PN-Z-04497:2018-09
PN-Z-04502:2019-10
PN-Z-04502:2019-10 Principles and Methods of Assessing the Working Environment 2021, No. 4 (110), pp. 179–189
PN-Z-04507:2022-05
PN-Z-04507:2022-05/Ap1:2022-08
PN-Z-04508:2022-05
PN-Z-04508:2022-05/Ap1:2022-08
PN-Z-04548:2023-03
Principles and Methods of Assessing the Working Environment 1998, issue 19
Principles and Methods of Assessing the Working Environment 2007, issue 51
Principles and Methods of Assessing the Working Environment 2012, No. 4 (74), pp. 117–130
Principles and Methods of Assessing the Working Environment 2014, issue 81