🇵🇱 POWIATOWA STACJA SANITARNO-EPIDEMIOLOGICZNA W ZAWIERCIU PL

PCA AB 626 • Zawiercie, Poland • 29 methods

Water & wastewaterMicrobiology

POWIATOWA STACJA SANITARNO-EPIDEMIOLOGICZNA W ZAWIERCIU is a laboratory accredited by PCA under number AB 626 (Zawiercie, Poland). Its accreditation scope covers 29 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water, Water, Water intended for human consumption, Swimming pool water, Water (including swimming pool water). Most frequently used techniques: Membrane filtration method, Spectrophotometric method, Plate method, pour plate.

At a glance

  • Accreditation number: PCA AB 626
  • Methods in scope: 29
  • Types of test objects: 6
  • Techniques used: 11
  • City: Zawiercie, Poland
Accreditation number
AB 626
Accreditation body
PCA
Address
ul. 11 Listopada 15, 42-400 Zawiercie
City
Zawiercie, Poland

What this laboratory tests (6)

Analytical techniques used (11)

Laboratory sections (2)

Laboratory locations

Certificate information

Issue date
22.07.2026
Issue no.
21

Accreditation scope — test methods (29)

No. Test object Methodology / Parameters Technique Reference document
Laboratory Department; Environmental Hygiene Testing Section
1 Water Chloride concentration
Range (5,0 – 400) mg/l
Titrimetric method PN-ISO 9297:1994
2 Water Nitrite nitrogen concentration
Range (0,003 – 0,25) mg/l Nitrite concentration Range (0,01 – 0,80) mg/l
Spectrophotometric method PN-EN 26777:1999
3 Water Ammonium nitrogen concentration
Range (0,04 – 2,0) mg/l Ammonium ion concentration Range (0,05 – 2,6) mg/l
Spectrophotometric method PN-C-04576-4:1994
4 Water Total manganese concentration
Range (0,015 – 2,0) mg/l
Spectrophotometric method Spectroquant test manufacturer's instructions No. 14770, Merck, edition: July 2024
5 Water Colour
Range (2-70) mg/l Pt
Spectrophotometric method PN-EN ISO 7887:2012+ Ap1:2015-06 Method C
6 Water Total iron concentration
Range (0,03 – 2,0) mg/l
Spectrophotometric method Spectroquant test manufacturer's instructions No. 14761, Merck, edition: March 2024
7 Water Total concentration of calcium and magnesium (total hardness)
Range (5,0 – 500) mg/l CaCO3
Titrimetric method PN-ISO 6059:1999
8 Water Electrical conductivity
Range (100 – 2 500) µS/cm
Conductometric method PN-EN 27888:1999
9 Water intended for human consumption Threshold flavour number (TFN) Threshold odour number (TON)
Range 1-2
Method: paired, unforced choice, simplified PN-EN 1622:2006
10 Water (including swimming pool water) pH
Range 4,0 – 10,0
Potentiometric method PN-EN ISO 10523:2012
11 Water (including swimming pool water) Turbidity
Range (0,10 – 40) NTU
Nephelometric method PN-EN ISO 7027-1:2016-09
12 Water (including swimming pool water) Nitrate nitrogen concentration
Range (0,1 – 20,0) mg/l Nitrate concentration Range (0,4 – 90,0) mg/l
Spectrophotometric method PN-82/C-04576/08
13 Swimming pool water Free chlorine concentration
Range (0,10 – 2,00) mg Cl2/l Total chlorine concentration Range (0,10 – 2,00) mg Cl2/l Combined chlorine concentration (calculated)
Colorimetric method OL/PB-06 issue 2 of 02.01.2020 | based on the Hanna Instruments test HI 96711-11 total chlorine, HI 96701-11 free chlorine
14 Swimming pool water Oxidising-reducing (redox) potential ref. to Ag/AgCl 3,5 mol/l KCl
Range (200 – 1000) mV
Potentiometric method OL/PB-07 issue 2 of 02.01.2020
15 Water, Water intended for human consumption Coliform bacteria count Membrane filtration method PN-ISO 9308-1:1999
16 Water, Water intended for human consumption Count of thermotolerant coliform bacteria, Escherichia coli Membrane filtration method PN-ISO 9308-1:1999
17 Water, Water intended for human consumption Total viable count at 36 °C Plate method, pour plate PN-EN ISO 6222:2004
18 Water, Water intended for human consumption Total viable count at 22 °C Plate method, pour plate PN-EN ISO 6222:2004
19 Water, Water intended for human consumption Enterococci count Membrane filtration method PN-EN ISO 7899-2:2004
20 Water, Water intended for human consumption Coliform bacteria count Membrane filtration method PN-EN ISO 9308 -1:2014-12+ A1:2017- 04
21 Water, Water intended for human consumption Escherichia coli count Membrane filtration method PN-EN ISO 9308 -1:2014-12 +A1:2017 -04
22 Water, Water intended for human consumption Number of Legionella bacteria, Matrix B: Procedure 7 – Medium C (GVPC) Membrane filtration method PN-EN ISO 11731:2017-08 + Ap1:2019-12
23 Swimming pool water Escherichia coli count Membrane filtration method PN-EN ISO 9308 -1:2014-12 +A1:2017 -04
24 Swimming pool water Total viable count at 36 °C Plate method, pour plate PN-EN ISO 6222:2004
25 Swimming pool water Count of coagulase-positive staphylococci Membrane filtration method OL/PB-02 issue 2 of 02.01.2020 based on the PZH guidelines PZH methodology ZHK:2007
26 Swimming pool water Pseudomonas aeruginosa count Membrane filtration method PN – EN ISO 16266:2009
27 Swimming pool water Number of Legionella bacteria, Matrix B: Procedure 7 – Medium C (GVPC) Membrane filtration method PN-EN ISO 11731:2017-08 + Ap1:2019-12
Laboratory Department; Infectious Diseases and Infections Testing Section
28 Faeces Presence of Salmonella spp. and Shigella spp. rods Culture method supplemented with biochemical and serological tests OL/PB-03 issue 3 of 19.11.2020, based on “Etiologia, obraz kliniczny i diagnostyka ostrych zakażeń i zarażeń przewodu pokarmowego oraz zatruć pokarmowych” (Aetiology, clinical picture and diagnosis of acute gastrointestinal infections and infestations and food poisoning), edited by Marek Jagielski, Warsaw 2010
29 Faeces Identification of Salmonella Enteritidis rods. Serological method OL/PB-03 issue 3 of 19.11.2020, based on “Etiologia, obraz kliniczny i diagnostyka ostrych zakażeń i zarażeń przewodu pokarmowego oraz zatruć pokarmowych” (Aetiology, clinical picture and diagnosis of acute gastrointestinal infections and infestations and food poisoning), edited by Marek Jagielski, Warsaw 2010

Reference standards (24)

Spectroquant test manufacturer's instructions No. 14761, Merck, edition: March 2024
Spectroquant test manufacturer's instructions No. 14770, Merck, edition: July 2024
OL/PB-02 issue 2 of 02.01.2020 based on the PZH guidelines PZH methodology ZHK:2007
OL/PB-03 issue 3 of 19.11.2020, based on “Etiologia, obraz kliniczny i diagnostyka ostrych zakażeń i zarażeń przewodu pokarmowego oraz zatruć pokarmowych” (Aetiology, clinical picture and diagnosis of acute gastrointestinal infections and infestations and food poisoning), edited by Marek Jagielski, Warsaw 2010
OL/PB-06 issue 2 of 02.01.2020
OL/PB-07 issue 2 of 02.01.2020
PN – EN ISO 16266:2009
PN-82/C-04576/08
PN-C-04576-4:1994
PN-EN 1622:2006
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN ISO 10523:2012
PN-EN ISO 11731:2017-08 + Ap1:2019-12
PN-EN ISO 6222:2004
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7887:2012+ Ap1:2015-06 Method C
PN-EN ISO 7899-2:2004
PN-EN ISO 9308 -1:2014-12 +A1:2017 -04
PN-EN ISO 9308 -1:2014-12+ A1:2017- 04
PN-ISO 6059:1999
PN-ISO 9297:1994
PN-ISO 9308-1:1999
based on the Hanna Instruments test HI 96711-11 total chlorine, HI 96701-11 free chlorine

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/PL/AB%20626