🇵🇱 POWIATOWA STACJA SANITARNO-EPIDEMIOLOGICZNA PL
Water & wastewaterEnvironmentMicrobiology
POWIATOWA STACJA SANITARNO-EPIDEMIOLOGICZNA is a laboratory accredited by PCA under number AB 622 (Zielona Góra, Poland). Its accreditation scope covers 101 test methods in the following areas: Water & wastewater, Environment, Microbiology. Test objects include: Water, water intended for human consumption, Workplace environment - air - air samples, Swimming pool water, Workplace environment - air. Most frequently used techniques: Gas chromatography with flame ionization detection (GC -FID), Membrane filtration method, Flame atomic absorption spectrometry (FAAS).
At a glance
- Accreditation number: PCA AB 622
- Methods in scope: 101
- Types of test objects: 16
- Techniques used: 29
- City: Zielona Góra, Poland
- Accreditation number
- AB 622
- Accreditation body
- PCA
- City
- Zielona Góra, Poland
What this laboratory tests (16)
- Water, water intended for human consumption — 34 methods
- Workplace environment - air - air samples — 26 methods
- Swimming pool water — 9 methods
- Workplace environment - air — 8 methods
- Water (including swimming pool water), water intended for human consumption — 5 methods
- Water intended for human consumption — 4 methods
- Water, bathing water, water at a place used for bathing — 3 methods
- Workplace environment - hand-arm vibration — 2 methods
- Workplace environment - noise — 2 methods
- Workplace environment - whole-body vibration — 2 methods
- Bacterial strain — 1 method
- Biological indicators of sterilization process efficacy (Sporal A, Sporal S) — 1 method
- Faeces, - from healthy persons — 1 method
- Faeces, Rectal swab — 1 method
- Faeces, Rectal swab -from convalescents - from carriers - from contacts — 1 method
- and 1 more
Analytical techniques used (29)
- Gas chromatography with flame ionization detection (GC -FID) — 13 methods
- Membrane filtration method — 11 methods
- Flame atomic absorption spectrometry (FAAS) — 8 methods
- Spectrophotometric method — 8 methods
- Gas chromatography with flame ionization detection (GC-FID) — 7 methods
- Culture method supplemented with biochemical and serological tests — 4 methods
- Titrimetric method — 4 methods
- Direct measurement method — 3 methods
- Electrothermal atomization atomic absorption spectrometry (ETAAS) — 3 methods
- Gravimetric method — 3 methods
- Hydride generation atomic absorption spectrometry (HGAAS) — 3 methods
- Plate method (pour plate) — 3 methods
- Colorimetric method — 2 methods
- Culture method with biochemical and serological confirmation — 2 methods
- Potentiometric method — 2 methods
- and 14 more
Laboratory sections (6)
- Laboratory Department; Working Environment Testing Section; Instrumental Analysis Section — 26 methods
- Laboratory Department; Environmental Testing Section — 25 methods
- Laboratory Department; Microbiology and Parasitology Section, Water Microbiology Laboratory — 19 methods
- Laboratory Department; Working Environment Testing Section — 14 methods
- Laboratory Department; Environmental Testing Section; Instrumental Analysis Section — 12 methods
- Laboratory Department; Microbiology and Parasitology Section, Medical Microbiology Laboratory — 5 methods
Laboratory locations
- POWIATOWA STACJA SANITARNO-EPIDEMIOLOGICZNA (main site) — Zielona Góra
- Laboratory Department — ul. Jasna 10, 65-470 Zielona Góra
- Environmental Testing Section — ul. Jasna 10, 65-470 Zielona Góra
- Instrumental Analysis Section — ul. Jasna 10, 65-470 Zielona Góra
- Microbiology and Parasitology Section, Water Microbiology Laboratory — ul. Jasna 10, 65-470 Zielona Góra
- Microbiology and Parasitology Section, Medical Microbiology Laboratory — ul. Jasna 10, 65-470 Zielona Góra
- Workplace Environment Testing Section — ul. Jasna 10, 65-470 Zielona Góra
Certificate information
- Issue date
- 02.07.2026
- Issue no.
- 25
Accreditation scope — test methods (101)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Laboratory Department; Environmental Testing Section | |||||
| 1 | Water intended for human consumption | Sampling for chemical and physical testing (including sensory testing) | PN-ISO 5667-5:2017-10 | ||
| 2 | Swimming pool water | Sampling for chemical and physical testing | PN-ISO 5667-5:2017-10 I/PO/OL/LBŚ-04-02 issue 2 of 25.03.2024 | ||
| 3 | Water intended for human consumption | Odour threshold number (TON) Range 1 Odour threshold number (TON) Range 1-4 |
Simplified paired method, non-forced choice; Full paired method, non-forced choice | PN-EN 1622:2006 | |
| 4 | Water intended for human consumption | Taste threshold number (TFN) Range 1 Taste threshold number (TFN) Range 1 - 4 |
Simplified, paired, unforced-choice method; Full paired, unforced-choice method | PN-EN 1622:2006 | |
| 5 | Water, water intended for human consumption | Electrical conductivity Range (140-2500) μS/cm |
Conductometric method | PN-EN 27888:1999 | |
| 6 | Water, water intended for human consumption | Colour Range (2-40) mg /l Pt |
Spectrophotometric method | PN-EN ISO 7887:2012 +Ap1:2015-06 Method C | |
| 7 | Water, water intended for human consumption | Iron concentration Range (20 – 2000) μg/l |
Spectrophotometric method | PN-ISO 6332:2001 +Ap1:2016-06 | |
| 8 | Water, water intended for human consumption | Nitrite concentration Range (0,016-0,65) mg/l |
Spectrophotometric method | PN-EN 26777:1999 | |
| 9 | Water, water intended for human consumption | Ammonium ion concentration Range (0,10-1,0) mg/l |
Spectrophotometric method | PB/LBŚ-25 issue 1 of 31.07.2020 | |
| 10 | Water, water intended for human consumption | Sulfate concentration Range (10-500) mg/l |
Gravimetric method | PN-ISO 9280:2002 | |
| 11 | Water, water intended for human consumption | Total cyanide concentration Range (5,0-100) μg/l |
Spectrophotometric method | PB/LBŚ-21 issue 2 of 30.12.2014 | based on Nanocolor test1-30 | |
| 12 | Water, water intended for human consumption | Chloride concentration Range (5,0-250) mg/l |
Titrimetric method | PN-ISO 9297:1994 | |
| 13 | Water, water intended for human consumption | Total content of calcium and magnesium (total hardness) Range (5-500) mg/l CaCO3 |
Titrimetric method | PN-ISO 6059:1999 | |
| 14 | Water, water intended for human consumption | Calcium concentration Range (2-100) mg/l |
Titrimetric method | PN-ISO 6058:1999 | |
| 15 | Water, water intended for human consumption | Magnesium concentration (calculated) | PN-C-04554-4:1999 | ||
| 16 | Water, water intended for human consumption | Boron concentration Range (0,10-2,5) mg/l |
Spectrophotometric method | PB/LBŚ-24 issue 3 of 20.12.2019 | based on HACH LANGE test LCK307 | |
| 17 | Water, water intended for human consumption | Anion concentrations chlorides (5,0-250) mg/l sulfates (5,0-250) mg/l |
Ion chromatography with conductometric detection (IC-CD) | PN-EN ISO 10304-1:2009 | |
| 18 | Water (including swimming pool water), water intended for human consumption | Turbidity Range (0,10-50) NTU |
Nephelometric method | PN-EN ISO 7027-1:2016-09 | |
| 19 | Water (including swimming pool water), water intended for human consumption | Nitrate concentration Range (0,90-89) mg/l |
Spectrophotometric method | PN-82/C-04576.08 | |
| 20 | Water (including swimming pool water), water intended for human consumption | Permanganate index Range (0,50-10) mg/l O2 |
Titrimetric method | PN-EN ISO 8467:2001 | |
| 21 | Water (including swimming pool water), water intended for human consumption | pH Range 4,0-10,0 |
Potentiometric method | PN-EN ISO 10523:2012 | |
| 22 | Water (including swimming pool water), water intended for human consumption | Free chlorine concentration ☑ Range (0,10-4,0) mg/l Regulated area: tests performed outside the Laboratory premises |
Colorimetric method | PB/LBŚ-26 issue 2 of 30.12.2022 | |
| 23 | Swimming pool water | Oxidation-reduction (redox) potential vs. Ag/AgCl 3,5 mol/l KCl ☑ Range (200-1000) mV Regulated area: tests performed outside the Laboratory premises |
Potentiometric method | PB/LBŚ-27 issue 1 of 05.03.2018 | |
| 24 | Swimming pool water | Total chlorine concentration ☑ Range (0,10-4,0) mg/l Free chlorine concentration Range (0,10-4,0) mg/l Regulated area: tests performed outside the Laboratory premises |
Colorimetric method | PB/LBŚ-26 issue 2 of 30.12.2022 | |
| 25 | Swimming pool water | Combined chlorine concentration (calculated) | PB/LBŚ-26 issue 2 of 30.12.2022 | ||
| Laboratory Department; Environmental Testing Section; Instrumental Analysis Section | |||||
| 26 | Water, water intended for human consumption | Mercury concentration Range (0,25 - 1,50) μg/l |
Cold vapour atomic absorption spectrometry (CVAAS) | PN-EN ISO 12846:2012 +Ap1:2016-07 | |
| 27 | Water, water intended for human consumption | Metal concentrations Cadmium (0,5 - 10,0) μg/l Lead (5,0 - 30,0) μg/l Nickel (5,0 - 25,0)μg/l Manganese (2,5 - 20,0) μg/l |
Electrothermal atomization atomic absorption spectrometry (ETAAS) | PN-EN ISO 15586:2005 | |
| 28 | Water, water intended for human consumption | Chromium concentration Range (1,0 - 60,0) μg/l |
Electrothermal atomization atomic absorption spectrometry (ETAAS) | PN-EN 1233:2000 | |
| 29 | Water, water intended for human consumption | Aluminium concentration Range (10,0 - 300) μg/l |
Electrothermal atomization atomic absorption spectrometry (ETAAS) | PN-EN ISO 12020:2002 | |
| 30 | Water, water intended for human consumption | Copper concentration Range (0,050 - 6,0) mg/l |
Flame atomic absorption spectrometry (FAAS) | PN-ISO 8288:2002 | |
| 31 | Water, water intended for human consumption | Manganese concentration Range (20,0 - 1000) μg/l |
Flame atomic absorption spectrometry (FAAS) | PB/LAI-06 issue 2 of 24.01.2024 | |
| 32 | Water, water intended for human consumption | Sodium concentration Range (0,40 - 300) mg/l |
Flame atomic emission spectrometry (FAES) | PN-ISO 9964-3:1994 | |
| 33 | Water, water intended for human consumption | Arsenic concentration Range (1,0 - 10) μg/l |
Hydride generation atomic absorption spectrometry (HGAAS) | PN-EN ISO 11969:1999 | |
| 34 | Water, water intended for human consumption | Antimony concentration Range (1,0 - 10) μg/l |
Hydride generation atomic absorption spectrometry (HGAAS) | PB/LAI-07 issue 1 of 14.12.2018 | |
| 35 | Water, water intended for human consumption | Selenium concentration Range (1,0 - 10) μg/l |
Hydride generation atomic absorption spectrometry (HGAAS) | PN-ISO 9965:2001 | |
| 36 | Water, water intended for human consumption | Element concentration Cadmium (1,5 - 10,0) μg/l Lead (3,0 - 20,0) μg/l Nickel (5,0-25,0) μg/l Manganese (10,0 – 150) μg/l Chromium (10,0 – 100) μg/l Aluminium (10,0 – 250) μg/l Iron (10,0 – 250) μg/l Copper (0,010 – 0,20) mg/l Sodium (1,0 – 250) mg/l Magnesium (1,0 – 150) mg/l |
Inductively coupled plasma optical emission spectrometry (ICP-OES) | PN-EN ISO 11885:2009 | |
| 37 | Water, water intended for human consumption | Element concentration Mercury (0,25 – 2,5) μg/l Arsenic (1,0 – 10,0) μg/l Antimony (1,0 – 10,0) μg/l Selenium (1,0 – 10,0) μg/l |
Hydride generation inductively coupled plasma optical emission spectrometry (HG-ICP-OES) | PN-EN ISO 11885:2009 | |
| Laboratory Department; Microbiology and Parasitology Section, Water Microbiology Laboratory | |||||
| 38 | Water intended for human consumption | Sampling for microbiological testing | PN-EN ISO 19458:2007 | ||
| 39 | Swimming pool water, bathing water, water at a site used for bathing | Sampling for microbiological testing | PN-EN ISO 19458:2007 | ||
| 40 | Swimming pool water | Pseudomonas aeruginosa count | Membrane filtration method | PN-EN ISO 16266:2009 | |
| 41 | Swimming pool water | Escherichia coli count | Membrane filtration method | PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/ A1:2017-04 | |
| 42 | Swimming pool water | Total viable count at 36°C | Plate method (pour plate) | PN-EN ISO 6222:2004 | |
| 43 | Swimming pool water | Count of coagulase – positive staphylococci | Membrane filtration method | NIZP-PZH methodology ZHK:2007 | |
| 44 | Swimming pool water | Number of Legionella bacteria, Matrix A, Procedure 5 (medium A), Procedure 7 (medium C - GVPC) | Membrane filtration method | PN-EN ISO 11731:2017-08 | |
| 45 | Water, water intended for human consumption | Total viable count at 22°C | Plate method (pour plate) | PN-EN ISO 6222:2004 | |
| 46 | Water, water intended for human consumption | Total viable count at 36°C | Plate method (pour plate) | PN-EN ISO 6222:2004 | |
| 47 | Water, water intended for human consumption | Coliform bacteria count | Membrane filtration method | PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/ A1:2017-04 | |
| 48 | Water, water intended for human consumption | Escherichia coli count | Membrane filtration method | PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/ A1:2017-04 | |
| 49 | Water, water intended for human consumption | Intestinal enterococci count | Membrane filtration method | PN-EN ISO 7899-2:2004 | |
| 50 | Water, water intended for human consumption | Pseudomonas aeruginosa count | Membrane filtration method | PN-EN ISO 16266:2009 | |
| 51 | Water, water intended for human consumption | Presence of Salmonella spp | Culture method with biochemical and serological confirmation | PN-EN ISO 19250:2013-07 | |
| 52 | Water, water intended for human consumption | Clostridium perfringens count including spores | Membrane filtration method | PN-EN ISO 14189:2016-10 | |
| 53 | Water, water intended for human consumption | Number of Legionella bacteria, Matrix A, Procedure 5 (medium A), Procedure 7 (medium C - GVPC) | Membrane filtration method | PN-EN ISO 11731:2017-08 | |
| 54 | Water, bathing water, water at a place used for bathing | Escherichia coli count | Most probable number method (MPN) | PN-EN ISO 9308-3:2002 | |
| 55 | Water, bathing water, water at a place used for bathing | Intestinal enterococci count | Membrane filtration method | PN-EN ISO 7899-2:2004 | |
| 56 | Water, bathing water, water at a place used for bathing | Presence of Salmonella spp | Culture method with biochemical and serological confirmation | PN-EN ISO 19250:2013-07 | |
| Laboratory Department; Microbiology and Parasitology Section, Medical Microbiology Laboratory | |||||
| 57 | Faeces, - from healthy persons | Presence of Salmonella and Shigella rods | Culture method supplemented with biochemical and serological tests | PB/LMiP-04 issue 3 of 22.02.2016 | based on the NIZP-PZH and KIDL Recommendations of 2015, the study edited by Marek Jagielski of 2010 published by KIDL, and the latex test manufacturer's instructions | |
| 58 | Faeces, Rectal swab -from convalescents - from carriers - from contacts | Presence of Salmonella and Shigella rods | Culture method supplemented with biochemical and serological tests | PB/LMiP-10 issue 3 of 22.02.2016 | based on the study edited by Marek Jagielski, 2010, published by KIDL | |
| 59 | Faeces, Rectal swab | Presence of pathogenic bacteria: Salmonella, Shigella, Yersinia sp. E.coli O157 |
Culture method supplemented with biochemical and serological tests | PB/LMiP-08 issue 3 of 22.02.2016 | based on the study edited by Marek Jagielski, 2010, published by KIDL | |
| 60 | Bacterial strain | Identification / re-identification of bacilli of the genus Salmonella, Shigella | Culture method supplemented with biochemical and serological tests | PB/LMiP-21 issue 3 of 21.12.2022 | based on the study edited by Marek Jagielski, 2010, published by KIDL | |
| 61 | Biological indicators of sterilization process efficacy (Sporal A, Sporal S) | Presence of indicator microorganisms Geobacillus stearothermophilus, Bacillus subtilis | Culture method | PB/LMiP-11 issue 3 of 04.01.2021 | based on the test manufacturer's instructions | |
| Laboratory Department; Working Environment Testing Section | |||||
| 62 | Workplace environment - noise | A-weighted equivalent sound level Maximum A-weighted sound level C-weighted peak sound level Range (20 - 135) dB |
Direct measurement method | PN-N-01307:1994 | PN-EN ISO 9612:2011 excluding the method covering strategy 3 –cl. 11 | |
| 63 | Workplace environment - noise | Noise exposure level referred to: an 8-hour daily working time the average weekly working time (calculated) |
PN-N-01307:1994 | PN-EN ISO 9612:2011 excluding the method covering strategy 3 –cl. 11 | ||
| 64 | Workplace environment - hand-arm vibration | Frequency-weighted r.m.s. vibration acceleration Range (0,2-100) m/s2 |
Direct measurement method | PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11 | |
| 65 | Workplace environment - hand-arm vibration | Daily exposure, expressed as the energy-equivalent value for an 8-hour working day of the vector sum of the frequency-corrected r.m.s. vibration accelerations, determined for the three directional components (ahwx, ahwy, ahwz ), Exposure lasting 30 minutes or less, expressed as the vector sum of the frequency-weighted r.m.s. vibration accelerations, determined for the three directional components (ahwx, ahwy, ahwz ) (calculated). | PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11 | ||
| 66 | Workplace environment - whole-body vibration | Frequency-weighted r.m.s. vibration acceleration Range (0,06-25) m/s2 |
Direct measurement method | PN-EN 14253+A1:2011 | |
| 67 | Workplace environment - whole-body vibration | Daily exposure, expressed as the 8-hour energy-equivalent frequency-weighted RMS vibration acceleration dominant among the vibration accelerations determined for the three directional components taking into account the appropriate coefficients (1,4 awx,1,4 awy , awz ), Exposure lasting 30 minutes and less, expressed as the frequency-weighted RMS vibration acceleration dominant among the vibration accelerations determined for the three directional components taking into account the appropriate coefficients (1,4 awx,1,4 awy , awz ) (calculated). | PN-EN 14253+A1:2011 | ||
| 68 | Workplace environment - air | Carbon monoxide concentration Range (2,3 - 130) mg/m3 |
Electrochemical method | PB/LBŚP-05 issue 4 of 01.12.2022 | |
| 69 | Workplace environment - air | Exposure indices (calculated) | PB/LBŚP-05 issue 4 of 01.12.2022 | ||
| 70 | Workplace environment - air | Sampling for the assessment of occupational exposure to: dust agents inhalable fraction respirable fraction organic substances inorganic substances, including: inhalable fraction respirable fraction thoracic fraction metals and their compounds, including: inhalable fraction respirable fraction |
Personal dosimetry method | PN-Z-04008-7:2002+Az1:2004 | |
| 71 | Workplace environment - air | Sampling for the assessment of occupational exposure to: inorganic substances |
Stationary method | PN-Z-04008-7:2002+Az1:2004 | |
| 72 | Workplace environment - air | Exposure index (calculated) | PN-Z-04008-7:2002+Az1:2004 | ||
| 73 | Workplace environment - air | Concentration of harmful dust agents – inhalable fraction: dusts not classified according to toxicity portland cement wood dusts organic dusts of animal and plant origin, excluding wood and flour dusts flour dusts hard coal and brown coal carbon black Range (0,20 - 17,4) mg/m3 |
Gravimetric method | PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08 | |
| 74 | Workplace environment - air | Concentration of harmful dust agents – respirable fraction: Portland cement, organic dusts of animal and plant origin excluding wood and flour dusts, hard coal and brown coal, Range (0,20 – 7,9) mg/m3 |
Gravimetric method | PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08 | |
| 75 | Workplace environment - air | Ammonia concentration/content Range (6,0 - 60,0) mg/m3 Range (0,020 - 0,20) mg in the sample |
Spectrophotometric method | PN-71/Z-04041 | |
| Laboratory Department; Working Environment Testing Section; Instrumental Analysis Section | |||||
| 76 | Workplace environment - air - air samples | Concentration/content of copper and its inorganic compounds – calculated as Cu Range (0,0028 - 0,33) mg/m3 Range (0,0020 - 0,24) mg in the sample |
Flame atomic absorption spectrometry (FAAS) | PN-79/Z-04106.02 | |
| 77 | Workplace environment - air - air samples | Concentration/content of iron oxides – calculated as Fe, iron(III) oxide, iron(II) oxide, triiron tetraoxide respirable fraction Range (0,18 – 26,3) mg/m3 Range (0,050 – 3,75) mg in the sample inhalable fraction Range (0,35 – 25,0) mg/m3 Range (0,050 – 7,5) mg in the sample |
Flame atomic absorption spectrometry (FAAS) | PN-Z-04469:2025-02 | |
| 78 | Workplace environment - air - air samples | Concentration/content of manganese and its inorganic compounds – calculated as Mn –inhalable fraction Range (0,017– 0,33) mg/m3 Range (0,012 - 0,24) mg in the sample -respirable fraction Range (0,0055 - 0,11) mg/m3 Range (0,0038 - 0,075) mg in the sample |
Flame atomic absorption spectrometry (FAAS) | PN-Z-04472:2015-10 +Ap1:2015-12 | |
| 79 | Workplace environment - air - air samples | Concentration/content of zinc oxide- expressed as Zn -inhalable fraction Range (0,14 - 16,6) mg/m3 Range (0,050 - 2,0) mg in the sample |
Flame atomic absorption spectrometry (FAAS) | PN-87/Z-04100.03 | |
| 80 | Workplace environment - air - air samples | Concentration/content of metallic chromium and chromium compounds (chromium (II), chromium (III), chromium (VI)) calculated as Cr Range (0,015 - 1,11) mg/m3 Range (0,011 - 0,80) mg in the sample |
Flame atomic absorption spectrometry (FAAS) | PB/LBŚP-01 issue 2 of 20.11.2018 | |
| 81 | Workplace environment - air - air samples | Concentration/content of lead and its inorganic compounds, excluding lead (II) arsenate (V) and lead (II) chromate (VI) – calculated as Pb, inhalable fraction Range (0,0035 - 0,11) mg/m3 Range (0,0025 - 0,080) mg in the sample |
Flame atomic absorption spectrometry (FAAS) | PN-Z-04487:2017-10 | |
| 82 | Workplace environment - air - air samples | Toluene concentration/content Range (2,4 - 628) mg/m3 Range (0,050 – 2,2) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-78/Z-04115.01 | |
| 83 | Workplace environment - air - air samples | Ethylbenzene concentration/content Range (4,8 – 857) mg/m3 Range (0,10 - 3,0) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-79/Z-04081.01 | |
| 84 | Workplace environment - air - air samples | Styrene concentration/content Range (1,0 - 571) mg/m3 Range (0,020 - 2,0) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PB/LAI-02 issue 3 of 04.01.2023 | |
| 85 | Workplace environment - air - air samples | Cyclohexanone concentration/content Range (1,0 - 285) mg/m3 Range (0,020 - 1,0) mg in the sample |
Gas chromatography with flame ionization detection (GC -FID) | PN-Z-04447:2014-06 | |
| 86 | Workplace environment - air - air samples | Concentration/content of xylene- mixture of isomers: 1,2-; 1,3-; 1,4- Range (4,8 - 628) mg/m3 Range (0,10 – 2,2) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-78/Z-04116.01 | |
| 87 | Workplace environment - air - air samples | Acetone concentration/content Range (24 - 1857) mg/m3 Range (0,50 - 6,5) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-79/Z-04057.01 | |
| 88 | Workplace environment - air - air samples | Concentration/content of organic substances ethyl acetate Range (24 - 2285) mg/m3 Range (0,50 - 8,0) mg in the sample n- butyl acetate (4,8 - 1142) mg/m3 (0,10 - 4,0) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-78/Z-04119.01 | |
| 89 | Workplace environment - air - air samples | Tetrachloroethene concentration/content Range (2,4 - 571) mg/m3 Range (0,050 - 2,0) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-78/Z-04118.01 | |
| 90 | Workplace environment - air - air samples | Hexane concentration/content Range (2,4 - 285) mg/m3 Range (0,050 - 1,0) mg in the sample |
Gas chromatography with flame ionization detection (GC -FID) | PN-Z-04136-3:2003 | |
| 91 | Workplace environment - air - air samples | Heptane concentration/content Range (24 - 2571) mg/m3 Range (0,50 - 9,0) mg in the sample |
Gas chromatography with flame ionization detection (GC -FID) | PN-84/Z-04138.02 | |
| 92 | Workplace environment - air - air samples | Concentration/content of butan-2-one, Range (15 - 1428) mg/m3 Range (0,30 - 5,0) mg in the sample |
Gas chromatography with flame ionization detection (GC -FID) | PN-Z-04449:2014-06 | |
| 93 | Workplace environment - air - air samples | Concentration/content of hexane saturated acyclic isomers, except hexane: Range 2-methylpentane (15 - 1428) mg/m3 Range (0,30 - 5,0) mg in the sample 3-methylpentane (15 - 1428) mg/m3 (0,30 - 5,0) mg in the sample |
Gas chromatography with flame ionization detection (GC -FID) | PB/LAI-03 issue 3 of 04.01.2023 | |
| 94 | Workplace environment - air - air samples | Cyclohexane concentration/content Range (9,5 - 1142) mg/m3 Range (0,20 - 4,0) mg in the sample |
Gas chromatography with flame ionization detection (GC -FID) | PN-86/Z-04151.02 | |
| 95 | Workplace environment - air - air samples | Benzene concentration/content Range (0,05 - 14) mg/m3 Range (0,0010 - 0,050) mg in the sample |
Gas chromatography with flame ionization detection (GC -FID) | PN-Z-04016-10:2005 | |
| 96 | Workplace environment - air - air samples | Ethylene oxide concentration/content Range (0,10 - 10) mg/m3 Range (0,0010 - 0,050) mg in the sample |
Gas chromatography with flame ionization detection (GC -FID) | PN-Z-04300:2002 | |
| 97 | Workplace environment - air - air samples | Concentration/content of organic substances propan- 2-ol Range (38 -2857) mg/m3 Range (0,80 - 10,0) mg in the sample 2-methylpropan-1-ol: (4,8 - 314) mg/m3 (0,10 - 1,1) mg in the sample |
Gas chromatography with flame ionization detection (GC -FID) | PB/LAI-04 issue 3 of 04.01.2023 | |
| 98 | Workplace environment - air - air samples | Concentration/content of ethyltoluene- mixture of isomers Range (4,8 - 628) mg/m3 Range (0,10 – 2,2) mg in the sample |
Gas chromatography with flame ionization detection (GC -FID) | PN-Z-04016-5:1998 | |
| 99 | Workplace environment - air - air samples | Concentration/content of trimethylbenzene- mixture of isomers (1,2,4-) Range (2,4 - 314) mg/m3 Range (0,050 - 1,1) mg in the sample |
Gas chromatography with flame ionization detection (GC -FID) | PN-Z-04016-4:1998 | |
| 100 | Workplace environment - air - air samples | Trichloroethene concentration/content Range (1,0 - 285) mg/m3 Range (0,020 - 1,0) mg in the sample |
Gas chromatography with flame ionization detection (GC -FID) | PN-78/Z-04047.02 | |
| 101 | Workplace environment - air - air samples | Pentane concentration/content Range (43 - 6171) mg/m3 Range (0,90 – 21,6) mg in the sample |
Gas chromatography with flame ionization detection (GC -FID) | PN-Z-04318:2005 | |
Reference standards (93)
NIZP-PZH methodology ZHK:2007
PB/LAI-02 issue 3 of 04.01.2023
PB/LAI-03 issue 3 of 04.01.2023
PB/LAI-04 issue 3 of 04.01.2023
PB/LAI-06 issue 2 of 24.01.2024
PB/LAI-07 issue 1 of 14.12.2018
PB/LBŚ-21 issue 2 of 30.12.2014
PB/LBŚ-24 issue 3 of 20.12.2019
PB/LBŚ-25 issue 1 of 31.07.2020
PB/LBŚ-26 issue 2 of 30.12.2022
PB/LBŚ-27 issue 1 of 05.03.2018
PB/LBŚP-01 issue 2 of 20.11.2018
PB/LBŚP-05 issue 4 of 01.12.2022
PB/LMiP-04 issue 3 of 22.02.2016
PB/LMiP-08 issue 3 of 22.02.2016
PB/LMiP-10 issue 3 of 22.02.2016
PB/LMiP-11 issue 3 of 04.01.2021
PB/LMiP-21 issue 3 of 21.12.2022
PN-71/Z-04041
PN-78/Z-04047.02
PN-78/Z-04115.01
PN-78/Z-04116.01
PN-78/Z-04118.01
PN-78/Z-04119.01
PN-79/Z-04057.01
PN-79/Z-04081.01
PN-79/Z-04106.02
PN-82/C-04576.08
PN-84/Z-04138.02
PN-86/Z-04151.02
PN-87/Z-04100.03
PN-C-04554-4:1999
PN-EN 1233:2000
PN-EN 14253+A1:2011
PN-EN 1622:2006
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN ISO 10304-1:2009
PN-EN ISO 10523:2012
PN-EN ISO 11731:2017-08
PN-EN ISO 11885:2009
PN-EN ISO 11969:1999
PN-EN ISO 12020:2002
PN-EN ISO 12846:2012 +Ap1:2016-07
PN-EN ISO 14189:2016-10
PN-EN ISO 15586:2005
PN-EN ISO 16266:2009
PN-EN ISO 19250:2013-07
PN-EN ISO 19458:2007
PN-EN ISO 5349-1:2004
PN-EN ISO 5349-2:2004
PN-EN ISO 5349-2:2004/A1:2015-11
PN-EN ISO 6222:2004
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7887:2012 +Ap1:2015-06 Method C
PN-EN ISO 7899-2:2004
PN-EN ISO 8467:2001
PN-EN ISO 9308-1:2014-12
PN-EN ISO 9308-1:2014-12/ A1:2017-04
PN-EN ISO 9308-3:2002
PN-EN ISO 9612:2011 excluding the method covering strategy 3 –cl. 11
PN-ISO 5667-5:2017-10
PN-ISO 5667-5:2017-10 I/PO/OL/LBŚ-04-02 issue 2 of 25.03.2024
PN-ISO 6058:1999
PN-ISO 6059:1999
PN-ISO 6332:2001 +Ap1:2016-06
PN-ISO 8288:2002
PN-ISO 9280:2002
PN-ISO 9297:1994
PN-ISO 9964-3:1994
PN-ISO 9965:2001
PN-N-01307:1994
PN-Z-04008-7:2002+Az1:2004
PN-Z-04016-10:2005
PN-Z-04016-4:1998
PN-Z-04016-5:1998
PN-Z-04136-3:2003
PN-Z-04300:2002
PN-Z-04318:2005
PN-Z-04447:2014-06
PN-Z-04449:2014-06
PN-Z-04469:2025-02
PN-Z-04472:2015-10 +Ap1:2015-12
PN-Z-04487:2017-10
PN-Z-04507:2022-05
PN-Z-04507:2022-05/Ap1:2022-08
PN-Z-04508:2022-05
PN-Z-04508:2022-05/Ap1:2022-08
based on the NIZP-PZH and KIDL Recommendations of 2015, the study edited by Marek Jagielski of 2010 published by KIDL, and the latex test manufacturer's instructions
based on the test manufacturer's instructions
based on the study edited by Marek Jagielski, 2010, published by KIDL
based on HACH LANGE test LCK307
based on Nanocolor test1-30