🇵🇱 CENTRALNE LABORATORIUM KRYMINALISTYCZNE POLICJI PL

PCA AB 596 • Warszawa, Poland • 10 methods

Materials & polymers

CENTRALNE LABORATORIUM KRYMINALISTYCZNE POLICJI is a laboratory accredited by PCA under number AB 596 (Warszawa, Poland). Its accreditation scope covers 10 test methods in the following areas: Materials & polymers. Test objects include: Tools and objects, closing devices, solid substrates, identificatio…, Carriers of gunshot residues, Devices of the nature of weapons and ammunition, Handwriting. Most frequently used techniques: Graphical – comparative method, Method: Analysis of toolmark traces, Method: flaw detection, etching.

At a glance

  • Accreditation number: PCA AB 596
  • Methods in scope: 10
  • Types of test objects: 9
  • Techniques used: 7
  • City: Warszawa, Poland
Accreditation number
AB 596
Accreditation body
PCA
Address
Al. Ujazdowskie 7, 00-583 Warszawa
City
Warszawa, Poland

What this laboratory tests (9)

Analytical techniques used (7)

Laboratory sections (5)

Laboratory locations

Certificate information

Issue date
08.04.2026
Issue no.
26

Accreditation scope — test methods (10)

No. Test object Methodology / Parameters Technique Reference document
Department of Document Examination and Digital Forensics; Al. Ujazdowskie 7, 00-583 Warszawa
1 Handwriting Graphic features of handwriting. Graphical – comparative method. BJ-W-IV-Pb-1, issue IV of 31.10.2022
2 Security documents Examination of alterations in documents. Optical methods: stereoscopic microscopy, analysis of absorption and luminescence in the near infrared. BJ-W-IV-Pb-2, issue V of 22.11.2022
Department of Weapons, Mechanoscopy and Road Accident Examinations; Al. Ujazdowskie 7, 00-583 Warszawa
3 Devices of the nature of weapons and ammunition Design and functional properties related to the ability to propel the effective charge over a distance and to the ability to fire the propelling charge. BJ-W-V-Pb-2, issue V of 31.10.2022
4 Tools and objects, closing devices, solid substrates, identification markings Group and individual identification. Determination of the integrity of separated objects. Method: Analysis of toolmark traces. BJ-W-V-Pb-1, issue IV of 31.10.2022
5 Tools and objects, closing devices, solid substrates, identification markings Identification markings. Analysis of structural composition, determination of the authenticity of markings, revealing of original markings. Method: flaw detection, etching. BJ-W-V-Pb-1, issue IV of 31.10.2022
Chemical Examination Department; Al. Ujazdowskie 7, 00-583 Warszawa
6 Carriers of gunshot residues Detection and identification of gunshot residues on carriers. Method: Scanning electron microscopy with energy dispersive X-ray detection (SEM/EDX) BJ-W-VI-Pb-3 issue VII of 09.03.2023
Genetic Examination Department; ul. Iwicka 14, 00-735 Warszawa
7 Material of human origin E Identification of the type of biological trace.
Specific characteristics of biological material. Individualisation of biological traces. DNA analysis of polymorphic STR systems.
E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories (calculated), The list of activities performed within the flexible scope of accreditation is made available on request by the accredited body. (calculated)
Regulated area: Tests performed for the purposes of the area regulated by the provisions of Council Framework Decision 2009/905/JHA of 30 November 2009.
Method: Immunochromatographic and biochemical.; Method: Multiplex PCR with capillary electrophoresis. BJ-W-VIII-Pb-1
Department of Dactyloscopic and Traceological Examinations; ul. Wiśniowa 58 A, 02-520 Warszawa
8 Substrates - carriers of papillary line traces Visualisation of fingerprint traces
Regulated area: Tests performed for the purposes of the area regulated by the provisions of Council Framework Decision 2009/905/JHA of 30 November 2009.
Techniques: Visual examination, DFO, 1,2-IND, Ninhydrin, PD, Cyanoacrylate fuming, Basic Yellow 40, Fingerprint powders: ferromagnetic, light, special, Wet Powder, SPR, Acid Black 1, Acid Yellow 7, Hungarian Red, DMAC, Sudan Black, Crystal violet, VMD, ORO. BJ-W-VII-Pb-1, issue IX of 09.12.2024
9 Impressions of finger, palm and foot friction ridges Identification of fingerprint impressions
Regulated area: Tests performed for the purposes of the area regulated by the provisions of Council Framework Decision 2009/905/JHA of 30 November 2009.
BJ-W-VII-Pb-1, issue IX of 09.12.2024
10 Substrates, casts, films with footwear and foot marks Toolmark examination. BJ-W-VII-Pb-2, issue VI of 28.11.2025

Reference standards (8)

BJ-W-IV-Pb-1, issue IV of 31.10.2022
BJ-W-IV-Pb-2, issue V of 22.11.2022
BJ-W-V-Pb-1, issue IV of 31.10.2022
BJ-W-V-Pb-2, issue V of 31.10.2022
BJ-W-VI-Pb-3 issue VII of 09.03.2023
BJ-W-VII-Pb-1, issue IX of 09.12.2024
BJ-W-VII-Pb-2, issue VI of 28.11.2025
BJ-W-VIII-Pb-1

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/PL/AB%20596