🇵🇱 TELE-COM Sp. z o. o. PL
EnvironmentMaterials & polymers
TELE-COM Sp. z o. o. is a laboratory accredited by PCA under number AB 529 (Poznań, Poland). Its accreditation scope covers 31 test methods in the following areas: Environment, Materials & polymers. Test objects include: Environment – electromagnetic field in the vicinity of radiocommuni…, Workplace environment − electromagnetic field from equipment used i…, Workplace environment − electromagnetic field originating from indu…, Workplace environment − electromagnetic field originating from radi…. Most frequently used techniques: Direct measurement method.
At a glance
- Accreditation number: PCA AB 529
- Methods in scope: 31
- Types of test objects: 9
- Techniques used: 1
- City: Poznań, Poland
- Accreditation number
- AB 529
- Accreditation body
- PCA
- Address
- LABORATORIUM BADAWCZE, ul. Jawornicka 8, 60-968 Poznań
- City
- Poznań, Poland
What this laboratory tests (9)
- Environment – electromagnetic field in the vicinity of radiocommunication and radionavigation installations (broadband measurements) — 5 methods
- Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy units - physiotherapy diathermy units — 4 methods
- Workplace environment − electromagnetic field originating from industrial installations and equipment: - arc welding equipment - resistance welding machines - dielectric heating equipment - induction heating equipment - industrial microwave furnaces, heaters and dryers, - equipment for the production and processing of plastics - soldering equipment - electrical discharge machines - resistance and arc furnaces - electric generators and motors - inverters - inductive metal detectors — 4 methods
- Workplace environment − electromagnetic field originating from radiocommunication and anti-theft systems: - handheld and cordless radiotelephones, short range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) - radar systems: stationary / non-stationary field - equipment emitting an electromagnetic field for purposes other than communication or location — 4 methods
- Environment – electromagnetic field in the vicinity of electric power substations and power lines — 3 methods
- Workplace environment − electromagnetic field in the workspace during the use of magnetotherapy or magnetostimulation devices — 3 methods
- Workplace environment − electromagnetic field in the workspace during the use of power systems and alternating current electrical supply installations in the power industry — 3 methods
- Workplace environment − electromagnetic field in the workspace during the use of transmitting devices of radiocommunication systems — 3 methods
- Environment – electromagnetic field in the vicinity of radar installations (broadband measurements) — 2 methods
Analytical techniques used (1)
- Direct measurement method — 21 methods
Certificate information
- Issue date
- 03.07.2025
- Issue no.
- 21
Accreditation scope — test methods (31)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Workplace environment − electromagnetic field originating from industrial installations and equipment: - arc welding equipment - resistance welding machines - dielectric heating equipment - induction heating equipment - industrial microwave furnaces, heaters and dryers, - equipment for the production and processing of plastics - soldering equipment - electrical discharge machines - resistance and arc furnaces - electric generators and motors - inverters - inductive metal detectors | Electric field strength: in the frequency range from 5 Hz up to 100 kHz Range 1 V/m – 50 kV/m in the frequency range from 0,1 MHz up to 6 GHz Range (0,8 – 1000) V/m |
Direct measurement method | PN-T-06580-3:2002 Method adapted to the regulated area IMB edition 4 of 05.06.2025 | |
| 2 | Workplace environment − electromagnetic field originating from industrial installations and equipment: - arc welding equipment - resistance welding machines - dielectric heating equipment - induction heating equipment - industrial microwave furnaces, heaters and dryers, - equipment for the production and processing of plastics - soldering equipment - electrical discharge machines - resistance and arc furnaces - electric generators and motors - inverters - inductive metal detectors | Magnetic field strength: in the frequency range from 0,1 MHz up to 30 MHz Range (0,01 – 16) A/m in the frequency range from 30 MHz up to 1000 MHz Range (0,01 – 10) A/m |
Direct measurement method | PN-T-06580-3:2002 Method adapted to the regulated area IMB edition 4 of 05.06.2025 | |
| 3 | Workplace environment − electromagnetic field originating from industrial installations and equipment: - arc welding equipment - resistance welding machines - dielectric heating equipment - induction heating equipment - industrial microwave furnaces, heaters and dryers, - equipment for the production and processing of plastics - soldering equipment - electrical discharge machines - resistance and arc furnaces - electric generators and motors - inverters - inductive metal detectors | Magnetic flux density: in the frequency range from 5 Hz up to 500 Hz Range 1 μT – 20 mT in the frequency range from 500 Hz up to 600 kHz Range (30 nT – 20 mT) |
Direct measurement method | PN-T-06580-3:2002 Method adapted to the regulated area IMB edition 4 of 05.06.2025 | |
| 4 | Workplace environment − electromagnetic field originating from industrial installations and equipment: - arc welding equipment - resistance welding machines - dielectric heating equipment - induction heating equipment - industrial microwave furnaces, heaters and dryers, - equipment for the production and processing of plastics - soldering equipment - electrical discharge machines - resistance and arc furnaces - electric generators and motors - inverters - inductive metal detectors | Magnetic field strength: in the frequency range from 5 Hz up to 600 kHz in the frequency range from 0,8 GHz up to 6 GHz (calculated) |
PN-T-06580-3:2002 Method adapted to the regulated area IMB edition 4 of 05.06.2025 | ||
| 5 | Workplace environment − electromagnetic field originating from radiocommunication and anti-theft systems: - handheld and cordless radiotelephones, short range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) - radar systems: stationary / non-stationary field - equipment emitting an electromagnetic field for purposes other than communication or location | Electric field strength: in the frequency range from 0,1 MHz up to 6 GHz Range (0,8 – 1000) V/m in the frequency range from 6 GHz up to 90 GHz Range (0,8 – 300) V/m |
Direct measurement method | PN-T-06580-3:2002 Method adapted to the regulated area IMB edition 4 of 05.06.2025 | |
| 6 | Workplace environment − electromagnetic field originating from radiocommunication and anti-theft systems: - handheld and cordless radiotelephones, short range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) - radar systems: stationary / non-stationary field - equipment emitting an electromagnetic field for purposes other than communication or location | Magnetic field strength: in the frequency range from 0,1 MHz up to 30 MHz Range (0,01 – 16) A/m in the frequency range from 30 MHz up to 1000 MHz Range (0,01 – 10) A/m |
Direct measurement method | PN-T-06580-3:2002 Method adapted to the regulated area IMB edition 4 of 05.06.2025 | |
| 7 | Workplace environment − electromagnetic field originating from radiocommunication and anti-theft systems: - handheld and cordless radiotelephones, short range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) - radar systems: stationary / non-stationary field - equipment emitting an electromagnetic field for purposes other than communication or location | Magnetic flux density: in the frequency range from 500 Hz up to 600 kHz Range (30 nT – 20 mT) |
Direct measurement method | PN-T-06580-3:2002 Method adapted to the regulated area IMB edition 4 of 05.06.2025 | |
| 8 | Workplace environment − electromagnetic field originating from radiocommunication and anti-theft systems: - handheld and cordless radiotelephones, short range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) - radar systems: stationary / non-stationary field - equipment emitting an electromagnetic field for purposes other than communication or location | Magnetic field strength: in the frequency range from 5 Hz up to 600 kHz in the frequency range from 0,8 GHz up to 90 GHz (calculated) |
PN-T-06580-3:2002 Method adapted to the regulated area IMB edition 4 of 05.06.2025 | ||
| 9 | Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy units - physiotherapy diathermy units | Electric field strength: in the frequency range from 0,1 MHz up to 6 GHz Range (0,8 – 1000) V/m |
Direct measurement method | PN-T-06580-3:2002 Method adapted to the regulated area IMB edition 4 of 05.06.2025 | |
| 10 | Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy units - physiotherapy diathermy units | Magnetic field strength: in the frequency range from 0,1 MHz up to 30 MHz Range (0,01 – 16) A/m in the frequency range from 30 MHz up to 1000 MHz Range (0,01 – 10) A/m |
Direct measurement method | PN-T-06580-3:2002 Method adapted to the regulated area IMB edition 4 of 05.06.2025 | |
| 11 | Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy units - physiotherapy diathermy units | Magnetic flux density: in the frequency range from 5 Hz up to 600 kHz Range (30 nT – 20 mT) |
Direct measurement method | PN-T-06580-3:2002 Method adapted to the regulated area IMB edition 4 of 05.06.2025 | |
| 12 | Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy units - physiotherapy diathermy units | Magnetic field strength: in the frequency range from 5 Hz up to 600 kHz in the frequency range from 0,8 GHz up to 6 GHz (calculated) |
PN-T-06580-3:2002 Method adapted to the regulated area IMB edition 4 of 05.06.2025 | ||
| 13 | Workplace environment − electromagnetic field in the workspace during the use of magnetotherapy or magnetostimulation devices | Electric field strength: in the frequency range from 5 Hz up to 100 kHz Range 1 V/m – 50 kV/m |
Direct measurement method | PiMOŚP No. 4(90) 2016 pp. 151-180 | |
| 14 | Workplace environment − electromagnetic field in the workspace during the use of magnetotherapy or magnetostimulation devices | Magnetic field strength: in the frequency range from 5 Hz up to 100 kHz (calculated) |
PiMOŚP No. 4(90) 2016 pp. 151-180 | ||
| 15 | Workplace environment − electromagnetic field in the workspace during the use of magnetotherapy or magnetostimulation devices | Magnetic flux density: in the frequency range from 5 Hz up to 500 Hz Range 1 μT – 20 mT in the frequency range from 500 Hz up to 100 kHz) Range (30 nT – 20 mT) |
Direct measurement method | PiMOŚP No. 4(90) 2016 pp. 151-180 | |
| 16 | Workplace environment − electromagnetic field in the workspace during the use of power systems and alternating current electrical supply installations in the power industry | Electric field strength: in the frequency range from 45 Hz up to 55 Hz Range (0,1 – 50) kV/m |
Direct measurement method | PiMOŚP No. 4(90) 2016 pp. 91-150 | |
| 17 | Workplace environment − electromagnetic field in the workspace during the use of power systems and alternating current electrical supply installations in the power industry | Magnetic field strength: in the frequency range from 45 Hz up to 55 Hz (calculated) |
PiMOŚP No. 4(90) 2016 pp. 91-150 | ||
| 18 | Workplace environment − electromagnetic field in the workspace during the use of power systems and alternating current electrical supply installations in the power industry | Magnetic flux density: in the frequency range from 45 Hz up to 55 Hz Range 1 μT – 20 mT |
Direct measurement method | PiMOŚP No. 4(90) 2016 pp. 91-150 | |
| 19 | Workplace environment − electromagnetic field in the workspace during the use of transmitting devices of radiocommunication systems | Electric field strength: in the frequency range from 0,1 MHz up to 300 MHz Range (0,8 – 1000) V/m in the frequency range from 0,3 GHz up to 6 GHz Range (0,8 – 1000) V/m in the frequency range from 6 GHz up to 90 GHz Range (0,8 – 280) V/m |
Direct measurement method | PiMOŚP No. 2(92) 2017 pp. 89-131 | |
| 20 | Workplace environment − electromagnetic field in the workspace during the use of transmitting devices of radiocommunication systems | Magnetic field strength: in the frequency range from 0,3 MHz up to 30 MHz Range (0,01 – 16) A/m in the frequency range from 30 MHz up to 1000 MHz Range (0,01 – 10) A/m |
Direct measurement method | PiMOŚP No. 2(92) 2017 pp. 89-131 | |
| 21 | Workplace environment − electromagnetic field in the workspace during the use of transmitting devices of radiocommunication systems | Magnetic field strength: in the frequency range from 0,8 GHz up to 90 GHz (calculated) |
PiMOŚP No. 2(92) 2017 pp. 89-131 | ||
| 22 | Environment – electromagnetic field in the vicinity of electric power substations and power lines | Electric field strength: in the frequency range 50 Hz Range (0,1 – 50) kV/m |
Direct measurement method | Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630) | |
| 23 | Environment – electromagnetic field in the vicinity of electric power substations and power lines | Magnetic flux density: in the frequency range 50 Hz Range (1 μT – 20 mT) |
Direct measurement method | Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630) | |
| 24 | Environment – electromagnetic field in the vicinity of electric power substations and power lines | Magnetic field strength: in the frequency range 50 Hz (calculated) |
Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630) | ||
| 25 | Environment – electromagnetic field in the vicinity of radiocommunication and radionavigation installations (broadband measurements) | Electric field strength: in the frequency range from 0,1 MHz up to 300 MHz Range (0,8 – 1000) V/m in the frequency range from 0,3 GHz up to 6 GHz Range (0,8 – 1000) V/m in the frequency range from 6 GHz up to 90 GHz Range (0,8 – 280) V/m |
Direct measurement method | Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630) | |
| 26 | Environment – electromagnetic field in the vicinity of radiocommunication and radionavigation installations (broadband measurements) | Magnetic field strength: in the frequency range from 100 kHz up to 30 MHz Range (0,01 – 16) A/m in the frequency range from 30 MHz up to 1 GHz Range (0,01 – 10) A/m |
Direct measurement method | Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630) | |
| 27 | Environment – electromagnetic field in the vicinity of radiocommunication and radionavigation installations (broadband measurements) | Magnetic field strength: in the frequency range: from 10 MHz up to 90 GHz (calculated) |
Clause 3 of the Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022, item 2630) | ||
| 28 | Environment – electromagnetic field in the vicinity of radiocommunication and radionavigation installations (broadband measurements) | Magnetic flux density: in the frequency range from 5 Hz up to 600 kHz Range (30 nT – 20 mT) |
Direct measurement method | Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630) | |
| 29 | Environment – electromagnetic field in the vicinity of radiocommunication and radionavigation installations (broadband measurements) | Magnetic field strength: in the frequency range from 5 Hz up to 600 kHz (calculated) |
Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630) | ||
| 30 | Environment – electromagnetic field in the vicinity of radar installations (broadband measurements) | Electric field strength: in the frequency range from 0,1 MHz up to 90 GHz Range (0,8 – 300) V/m |
Direct measurement method | Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630) | |
| 31 | Environment – electromagnetic field in the vicinity of radar installations (broadband measurements) | Magnetic field strength: in the frequency range from 10 MHz up to 90 GHz (calculated) |
Clause 3 of the Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022, item 2630) | ||
Reference standards (6)
PN-T-06580-3:2002 Method adapted to the regulated area IMB edition 4 of 05.06.2025
PiMOŚP No. 2(92) 2017 pp. 89-131
PiMOŚP No. 4(90) 2016 pp. 151-180
PiMOŚP No. 4(90) 2016 pp. 91-150
Clause 3 of the Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022, item 2630)
Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630)