🇵🇱 TECHNO-SERVICE PL
EnvironmentMaterials & polymers
TECHNO-SERVICE is a laboratory accredited by PCA under number AB 481 (Gdańsk, Poland). Its accreditation scope covers 95 test methods in the following areas: Environment, Materials & polymers. Test objects include: Workplace environment − air – air samples collected on filters, Workplace environment − air – air samples collected on sorbent tubes, General environment – waste gas samples collected on sorbent tubes, Workplace environment − air. Most frequently used techniques: Gas chromatography with flame ionization detection (GC-FID), Flame atomic absorption spectrometry (FAAS), Direct measurement method.
At a glance
- Accreditation number: PCA AB 481
- Methods in scope: 95
- Types of test objects: 24
- Techniques used: 14
- City: Gdańsk, Poland
- Accreditation number
- AB 481
- Accreditation body
- PCA
- Address
- PRACOWNIA BADAŃ ŚRODOWISKOWYCH SP. Z O.O., ul. Konrada Leczkowa 22a, 80-432 Gdańsk
- City
- Gdańsk, Poland
What this laboratory tests (24)
- Workplace environment − air – air samples collected on filters — 23 methods
- Workplace environment − air – air samples collected on sorbent tubes — 18 methods
- General environment – waste gas samples collected on sorbent tubes — 7 methods
- Workplace environment − air — 7 methods
- Workplace environment – air – air samples collected into absorbing solution — 4 methods
- General environment – waste gas samples collected into absorbing solution — 3 methods
- Rooms in residential, collective residence and public utility buildings – air samples collected on sorbent tubes — 3 methods
- Rooms in residential, collective residence and public utility buildings − air – air samples collected on sorbent tubes — 3 methods
- General environment - noise from installations, equipment and industrial plants — 2 methods
- Rooms and open decks on ships - noise — 2 methods
- Rooms in residential, collective residence and public utility buildings - noise — 2 methods
- Workplace environment - cold microclimate — 2 methods
- Workplace environment - hand-arm vibration — 2 methods
- Workplace environment - hot microclimate — 2 methods
- Workplace environment - moderate microclimate — 2 methods
- and 9 more
Analytical techniques used (14)
- Gas chromatography with flame ionization detection (GC-FID) — 32 methods
- Flame atomic absorption spectrometry (FAAS) — 17 methods
- Direct measurement method — 11 methods
- Spectrophotometric method — 7 methods
- Atomic emission spectrometry (FES) — 2 methods
- Direct measurement method; Sampling method — 2 methods
- Gravimetric method — 2 methods
- High-performance liquid chromatography with diode array detection (HPLC-DAD) — 2 methods
- Electrochemical method — 1 method
- Fourier transform infrared spectrometry (FT-IR) — 1 method
- Personal dosimetry method — 1 method
- Personal dosimetry method; Stationary method — 1 method
- Stationary method — 1 method
- Turbidimetric method — 1 method
Laboratory locations
- TECHNO-SERVICE (main site) — ul. Konrada Leczkowa 22a, 80-432 Gdańsk
- PRACOWNIA BADAŃ ŚRODOWISKOWYCH SP. Z O.O. — ul. Konrada Leczkowa 22a
- Techno-Service Pracownia Badań Środowiskowych Sp. z o.o.
Certificate information
- Issue date
- 22.04.2026
- Issue no.
- 28
Accreditation scope — test methods (95)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Techno-Service Pracownia Badań Środowiskowych Sp. z o.o. | |||||
| 1 | Workplace environment − air | Sampling for the assessment of occupational exposure to: dust agents inhalable fraction respirable fraction |
Personal dosimetry method | PN-Z-04008-7:2002+Az1:2004 | PN-EN 689+AC:2019-06 | |
| 2 | Workplace environment − air | Sampling for the assessment of occupational exposure to: organic substances, including inhalable fraction inorganic substances, including inhalable fraction respirable fraction thoracic fraction metals and their compounds, including inhalable fraction respirable fraction respirable asbestos fibres refractory ceramic fibres refractory ceramic fibres mixed with other man-made mineral fibres respirable fibres of man-made mineral fibres, excluding refractory ceramic fibres silicon carbide fibrous – respirable fibres |
Personal dosimetry method; Stationary method | PN-Z-04008-7:2002+Az1:2004 | PN-EN 689+AC:2019-06 | |
| 3 | Workplace environment − air | Exposure index (calculated) | PN-Z-04008-7:2002+Az1:2004 | PN-EN 689+AC:2019-06 | ||
| 4 | Workplace environment − air | Concentration of harmful dust agents - inhalable fraction: apatites and phosphorites petroleum bitumen portland cement titanium dioxide natural graphite synthetic graphite kaolin amorphous and synthetic silica wood dusts flour dusts dusts not classified according to toxicity organic dusts of animal and plant origin, excluding wood and flour dusts calcium sulfate(VI) (gypsum) carbon black man-made mineral fibres, excluding refractory ceramic fibres talc coal (hard, brown) calcium magnesium carbonate (dolomite) silicon carbide, non-fibrous silicon carbide fibrous Range (0,12 - 20,4) mg/m3 |
Gravimetric method | PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08 | |
| 5 | Workplace environment − air | Concentration of harmful dust agents - respirable fraction: apatites and phosphorites portland cement natural graphite amorphous and synthetic silica organic dusts of animal and plant origin, excluding wood and flour dusts talc coal (hard, brown) Range (0,05 - 14,6) mg/m3 |
Gravimetric method | PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08 | |
| 6 | Workplace environment − air | Gas concentrations CO (2,3 - 120) mg/m³ NO (0,13 - 65) mg/m³ NO2 (0,19 - 38) mg/m³ |
Electrochemical method | Test procedure TSO/PB-14 issue 3 of 19.12.2014 | |
| 7 | Workplace environment − air | Exposure indices (calculated) | Test procedure TSO/PB-14 issue 3 of 19.12.2014 | ||
| 8 | Workplace environment − air – air samples collected on filters | Concentration/content of crystalline silica – quartz, cristobalite – respirable fraction Range (0,004 - 0,5) mg/m3 Range (5 - 400) µg in the sample |
Fourier transform infrared spectrometry (FT-IR) | Principles and Methods of Assessing the Working Environment 2012, No. 4 (74), pp. 117–130 | |
| 9 | Workplace environment − air – air samples collected on filters | Concentration / content of metallic chromium and its compounds (chromium (II), chromium (III), chromium (VI) – expressed as Cr Range (0,003 - 1) mg/m3 Range from 2 μg to 10 mg in the sample |
Flame atomic absorption spectrometry (FAAS) | PN-Z-04434:2011 | |
| 10 | Workplace environment − air – air samples collected on filters | Concentration of metallic chromium, chromium compounds: chromium (II) – calculated as Cr (II), chromium (III) – calculated as Cr (III) (calculated) | Test procedure TSO/PB-02 issue 1 of 17.03.2022 | ||
| 11 | Workplace environment − air – air samples collected on filters | Concentration/content of chromium (VI) compounds – calculated as chromium (VI) Range (0,0005 - 0,03) mg/m3 Range (0,6 - 40) μg in the sample |
Spectrophotometric method | PN-87/Z-04126/03 | |
| 12 | Workplace environment − air – air samples collected on sorbent tubes | Concentration/Content of organic compounds: acetone acetonitrile dichloromethane ethanol diethyl ether methyl acetate propan-2-ol (isopropyl alcohol) saturated acyclic isomers of hexane, excluding hexane: 2,2-dimethylbutane, sum of 2,3-dimethylbutane and 2-methylpentane, 3-methylpentane Range (2,5 - 5882) mg/m³ Range (25 - 10 000) µg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | Test procedure TSO/PB-08 issue 10 of 10.04.2024 | |
| 13 | Workplace environment − air – air samples collected on sorbent tubes | Carbon tetrachloride concentration/content Range (0,69 - 1667) mg/m3 Range (25 - 10 000) µg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | Test procedure TSO/PB-08 issue 10 of 10.04.2024 | |
| 14 | Workplace environment − air – air samples collected on sorbent tubes | Concentration/Content of organic compounds: 2-methoxyethanol 2-methoxyethyl acetate Range (0,42 - 1000) mg/m3 Range (25 - 10 000) µg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | Test procedure TSO/PB-08 issue 10 of 10.04.2024 | |
| 15 | Workplace environment − air – air samples collected on sorbent tubes | Concentration/Content of organic compounds: chloroform 2-ethoxyethanol 2-ethoxyethyl acetate vinyl acetate Range (0,83 - 2000) mg/m3 Range (25 - 10 000) µg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | Test procedure TSO/PB-08 issue 10 of 10.04.2024 | |
| 16 | Workplace environment − air – air samples collected on sorbent tubes | Concentration/Content of benzene Range (0,03 - 20) mg/m3 Range (1 - 200) µg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | Test procedure TSO/PB-08 issue 10 of 10.04.2024 | |
| 17 | Workplace environment − air – air samples collected on sorbent tubes | Concentration/content of organic compounds decane hexane heptane nonane octane pentane undecane butan-1-ol cyclohexanone 2-methylpropan-1-ol n-butyl acetate ethyl acetate ethylbenzene xylene – mixture of isomers: 1,2-; 1,3-;1,4- styrene toluene trimethylbenzene – mixture of isomers: (1,2,3-, 1,2,4- and 1,3,5-) propylbenzene butan-2-one (methyl ethyl ketone) 2-butoxyethanol chlorobenzene butyl methacrylate methyl methacrylate 1-methoxypropan-2-ol methylcyclohexane 4-methylpentan- 2-one (methyl isobutyl ketone) 2-butoxyethyl acetate isobutyl acetate isopropyl acetate 2-methoxy-1-methylethyl acetate propyl acetate propan-1-ol tetrachloroethene trichloroethene dodecane tridecane Range (1,39 - 5882) mg/m³ Range (25 - 10 000) µg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | Test procedure TSO/PB-08 issue 10 of 10.04.2024 | |
| 18 | Workplace environment − air – air samples collected on sorbent tubes | Concentration/Content of extraction naphtha Range (5,6 - 5333) mg/m³ Range (100 - 4000) µg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-81/Z-04134.02 excluding cl. 5, 8. | Test procedure TSO/PB-08 issue 10 of 10.04.2024 cl. 5, 7, 8, 9.1, 11. | |
| 19 | Workplace environment − air – air samples collected on sorbent tubes | Concentration/Content of varnish naphtha Range (5,6 - 5333) mg/m³ Range (100 - 4000) µg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-81/Z-04134.03 excluding cl. 5, 8. | Test procedure TSO/PB-08 issue 10 of 10.04.2024 cl. 5, 7, 8, 9.1, 11. | |
| 20 | Workplace environment − air – air samples collected on sorbent tubes | Concentration/Content of kerosene Range (5,6 - 5333) mg/m³ Range (100 - 4000) µg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-92/Z-04227/02 excluding cl. 8. | Test procedure TSO/PB-08 issue 10 of 10.04.2024 cl. 5, 7, 8, 9.1, 11 | |
| 21 | Workplace environment − air – air samples collected on sorbent tubes | Cumene (2-phenylpropane, isopropylbenzene) concentration/content Range (0,17 - 400) mg/m3 Range (10 - 10000) µg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04016-6:1998 | |
| 22 | Workplace environment − air – air samples collected on sorbent tubes | Concentration/Content of acetic acid Range (0,42 - 400) mg/m3 Range (25 - 10 000) µg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04323:2004 | |
| 23 | Workplace environment − air – air samples collected on sorbent tubes | Concentration/Content of phenol, cresol – mixture of isomers Range (0,07 - 80) mg/m3 Range (2 - 1000) µg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | Principles and Methods of Assessing the Working Environment, 1999, No. 22, CIOP | |
| 24 | Workplace environment − air – air samples collected on sorbent tubes | Concentration/Content of 2-(2-butoxyethoxy)ethanol Range (0,83 - 600) mg/m3 Range (50 - 1500) µg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04399:2011 | |
| 25 | Workplace environment − air – air samples collected on sorbent tubes | Concentration/Content of cyclohexane Range (3,3 - 4000) mg/m3 Range (200 - 5000) µg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-86/Z-04151/02 | |
| 26 | Workplace environment − air – air samples collected on sorbent tubes | Concentration/Content of 1-ethyl-2-pyrrolidone Range (0,42 - 500) mg/m3 Range (20 - 1000) µg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | Principles and Methods of Assessing the Working Environment 2022, No. 2 (112), pp. 111–126 | |
| 27 | Workplace environment − air – air samples collected on sorbent tubes | Concentration/Content of 1-methyl-2-pyrrolidone Range (0,42 - 500) mg/m3 Range (20 - 1000) µg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | Principles and Methods of Assessing the Working Environment 2022, No. 2 (112), pp. 127–142 | |
| 28 | Workplace environment − air – air samples collected on sorbent tubes | Formaldehyde concentration/content Range (0,0033 - 20) mg/m3 Range (0,2 - 100) µg in the sample |
High-performance liquid chromatography with diode array detection (HPLC-DAD) | Principles and Methods of Assessing the Working Environment, 1999, No. 22, pp. 96-100 | |
| 29 | Workplace environment − air – air samples collected on sorbent tubes | Concentration/Content of acrylaldehyde Range (0,0033 - 10) mg/m3 Range (0,2 - 50) µg in the sample |
High-performance liquid chromatography with diode array detection (HPLC-DAD) | PN-Z-04045-16:2010 | |
| 30 | Workplace environment − air – air samples collected on filters | Concentration/Content of tin and its inorganic compounds, except stannane – calculated as Sn inhalable fraction Range (0,07 - 4) mg/m3 Range from 50 μg to 150 mg in the sample |
Flame atomic absorption spectrometry (FAAS) | PN-Z-04488:2017-10 | |
| 31 | Workplace environment − air – air samples collected on filters | Concentration/content of zinc oxide – calculated as Zn inhalable fraction Range (0,001 - 10) mg/m3 Range from 1 μg to 5 mg in the sample |
Flame atomic absorption spectrometry (FAAS) | PN-87/Z-04100/03 | |
| 32 | Workplace environment − air – air samples collected on filters | Concentration/content of metallic aluminium, aluminium powder (unstabilised) inhalable fraction respirable fraction Range (0,01 - 11) mg/m3 Range from 10 μg to 150 mg in the sample |
Flame atomic absorption spectrometry (FAAS) | PN-Z-04263-1:2012 | |
| 33 | Workplace environment − air – air samples collected on filters | Aluminium trioxide concentration/content – calculated as Al inhalable fraction respirable fraction Range (0,01 - 11) mg/m3 Range from 10 μg to 150 mg in the sample |
Flame atomic absorption spectrometry (FAAS) | PN-Z-04263-1:2012 | |
| 34 | Workplace environment − air – air samples collected on filters | Concentration/content of cobalt and its inorganic compounds – calculated as Co Range (0,0014 - 0,14) mg/m3 Range (1 - 100) μg in the sample |
Flame atomic absorption spectrometry (FAAS) | PN-Z-04291:2003 | |
| 35 | Workplace environment − air – air samples collected on filters | Aluminium hydroxide concentration/content – calculated as Al inhalable fraction respirable fraction Range (0,01 - 11) mg/m3 Range from 10 μg to 150 mg in the sample |
Flame atomic absorption spectrometry (FAAS) | PN-Z-04263-1:2012 | |
| 36 | Workplace environment − air – air samples collected on filters | Magnesium oxide concentration/content inhalable fraction Range (0,004 - 20) mg/m3 Range from 4,1 μg to 25 mg in the sample |
Flame atomic absorption spectrometry (FAAS) | PN-Z-04470:2015-10 | |
| 37 | Workplace environment − air – air samples collected on filters | Concentration/content of manganese and its inorganic compounds – calculated as Mn inhalable fraction respirable fraction Range (0,001 - 0,6) mg/m3 Range from 1 μg to 15 mg in the sample |
Flame atomic absorption spectrometry (FAAS) | PN-Z-04472:2015-10+Ap1:2015-12 | |
| 38 | Workplace environment − air – air samples collected on filters | Concentration/content of copper and its inorganic compounds – calculated as Cu Range (0,001 - 2,0) mg/m3 Range from 1 μg to 10 mg in the sample |
Flame atomic absorption spectrometry (FAAS) | PN-79/Z-04106.02 | |
| 39 | Workplace environment − air – air samples collected on filters | Concentration/Content of metallic nickel Range (0,003 - 0,5) mg/m3 Range from 2 μg to 10 mg in the sample |
Flame atomic absorption spectrometry (FAAS) | PN-Z-04502:2019-10 | |
| 40 | Workplace environment − air – air samples collected on filters | Concentration/content of nickel compounds - calculated as Ni inhalable fraction respirable fraction Range (0,001 - 0,14) mg/m3 Range (0,8 - 100) µg in the sample |
Flame atomic absorption spectrometry (FAAS) | Principles and Methods of Assessing the Working Environment 2021, No. 4 (110), pp. 179–189 | |
| 41 | Workplace environment − air – air samples collected on filters | Concentration/content of lead and its inorganic compounds – calculated as Pb inhalable fraction Range (0,002 - 0,07) mg/m3 Range from 1,5 μg to 10 mg in the sample |
Flame atomic absorption spectrometry (FAAS) | PN-Z-04487:2017-10 | |
| 42 | Workplace environment − air – air samples collected on filters | Silver concentration/content inhalable fraction Silver, insoluble compounds – calculated as Ag Range (0,001 - 0,07) mg/m3 Range from 1 μg to 10 mg in the sample |
Flame atomic absorption spectrometry (FAAS) | PN-Z-04216-2:2012 | |
| 43 | Workplace environment − air – air samples collected on filters | Calcium oxide concentration/content inhalable fraction respirable fraction Range (0,01 - 18,7) mg/m3 Range from 14 μg to 28 mg in the sample |
Flame atomic absorption spectrometry (FAAS) | PN-Z-04442:2023-05 | |
| 44 | Workplace environment − air – air samples collected on filters | Calcium hydroxide concentration/content inhalable fraction respirable fraction Range (0,02 - 7,4) mg/m3 Range from 19 μg to 37 mg in the sample |
Flame atomic absorption spectrometry (FAAS) | PN-Z-04497:2018-09 | |
| 45 | Workplace environment − air – air samples collected on filters | Concentration/Content of iron oxides – calculated as Fe iron (III) oxide, iron (II) oxide, triiron tetraoxide inhalable fraction respirable fraction Range (0,003 - 25) mg/m3 Range from 2 μg to 150 mg in the sample |
Flame atomic absorption spectrometry (FAAS) | PN-Z-04469:2025-02 | |
| 46 | Workplace environment − air – air samples collected on filters | Concentration/Content of sodium hydroxide Range (0,002 - 1,4) mg/m3 Range from 2 μg to 23 mg in the sample |
Atomic emission spectrometry (FES) | PN-Z-04435:2011 | |
| 47 | Workplace environment − air – air samples collected on filters | Concentration/Content of potassium hydroxide Range (0,001 - 1,4) mg/m3 Range from 1 μg to 22 mg in the sample |
Atomic emission spectrometry (FES) | PN-Z-04436:2011 | |
| 48 | Workplace environment − air – air samples collected on filters | Hydrogen chloride concentration/content Range (0,35 - 69) mg/m³ Range (0,05 - 5) mg in the sample |
Turbidimetric method | PN-Z-04450:2014-08 | |
| 49 | Workplace environment – air – air samples collected into absorbing solution | Concentration/Content of ammonia Range (1 - 60) mg/m3 Range (0,04 - 4) mg in the sample |
Spectrophotometric method | PN-71/Z-04041 | |
| 50 | Workplace environment – air – air samples collected into absorbing solution | Concentration/Content of methanol Range (4 - 400) mg/m3 Range (10 - 1000) µg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-81/Z-04028.01 | |
| 51 | Workplace environment – air – air samples collected into absorbing solution | Formaldehyde concentration/content Range (0,025 - 3,3) mg/m3 Range (0,0015 - 0,12) mg in the sample |
Spectrophotometric method | Test procedure TSO/PB-06 issue 4 of 19.12.2014 | |
| 52 | Workplace environment – air – air samples collected into absorbing solution | Concentration/Content of chlorine Range (0,008 - 3) mg/m³ Range (1 - 15) µg in the sample |
Spectrophotometric method | PN-75/Z-04037.03 | |
| 53 | General environment − air | Air sampling for determination of respirable asbestos fibres | Test procedure TSO/PB-04 issue 7 of 01.12.2008 | ||
| 54 | Rooms in residential, collective residence and public utility buildings − air | Air sampling for determination of: respirable asbestos fibres organic substances |
Stationary method | Test procedure TSO/PB-04 issue 7 of 01.12.2008 | |
| 55 | Rooms in residential, collective residence and public utility buildings − air – air samples collected into absorbing solution | Formaldehyde concentration/content Range (20 - 1333) µg/m3 Range (0,0015 - 0,12) mg in the sample |
Spectrophotometric method | Test procedure TSO/PB-06 issue 4 of 19.12.2014 | |
| 56 | Rooms in residential, collective residence and public utility buildings – air samples collected into absorbing solution | Methanol content Range (10 - 1000) µg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-81/Z-04028.01 | |
| 57 | Rooms in residential, collective residence and public utility buildings – air samples collected on sorbent tubes | Acetic acid content Range (25 - 10 000) µg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04323:2004 | |
| 58 | Rooms in residential, collective residence and public utility buildings – air samples collected on sorbent tubes | Concentration/Content of organic compounds: acetone butan-1-ol cyclohexanone 2-methylpropan-1-ol butyl acetate ethyl acetate Range (4 - 10 000) µg/m³ Range (2 - 10 000) µg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | Test procedure TSO/PB-08 issue 10 of 10.04.2024 | |
| 59 | Rooms in residential, collective residence and public utility buildings – air samples collected on sorbent tubes | Concentration/content of aromatic hydrocarbons benzene Range (2 - 500) µg/m³ Range (1 - 200) µg in the sample ethylbenzene o-xylene m-xylene p-xylene styrene toluene trimethylbenzene – mixture of isomers (1,2,3-, 1,2,4- and 1,3,5-) Range (4 - 10 000) µg/m³ Range (2 - 10 000) µg in the sample propylbenzene Range (52 - 10 000) µg/m³ Range (25 - 10 000) µg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | Test procedure TSO/PB-08 issue 10 of 10.04.2024 | |
| 60 | Rooms in residential, collective residence and public utility buildings − air – air samples collected on sorbent tubes | Concentration/content of aliphatic hydrocarbons decane hexane heptane nonane octane pentane undecane Range (4 - 10 000) µg/m³ Range (2 - 10 000) µg in the sample dodecane tridecane Range (52 - 10 000) µg/m³ Range (25 - 10 000) µg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | Test procedure TSO/PB-08 issue 10 of 10.04.2024 | |
| 61 | Rooms in residential, collective residence and public utility buildings − air – air samples collected on sorbent tubes | Concentration/Content of phenol, o-cresol, m-cresol, p-cresol Range (4 - 1000) µg/m3 Range (2 - 1000) µg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | Principles and Methods of Assessing the Working Environment, 1999, No. 22, CIOP | |
| 62 | Rooms in residential, collective residence and public utility buildings − air – air samples collected on sorbent tubes | Concentration/Content of organic compounds: acetonitrile butan-2-one (methyl ethyl ketone) 2-butoxyethanol chlorobenzene chloroform dichloromethane ethanol diethyl ether 2-ethoxyethanol butyl methacrylate methyl methacrylate 2-methoxyethanol 1-methoxypropan-2-ol 4-methylpentan- 2-one (methyl isobutyl ketone) 2-butoxyethyl acetate 2-ethoxyethyl acetate isopropyl acetate 2-methoxyethyl acetate 2-methoxy-1-methylethyl acetate methyl acetate propyl acetate vinyl acetate propan-1-ol propan-2-ol (isopropyl alcohol) carbon tetrachloride tetrachloroethene trichloroethene Range (52 - 10 000) µg/m³ Range (25 - 10 000) µg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | Test procedure TSO/PB-08 issue 10 of 10.04.2024 | |
| 63 | General environment – waste gas samples collected on sorbent tubes | Organic compound content: acetone butan-1-ol cyclohexanone 2-methylpropan-1-ol butyl acetate ethyl acetate Range (2 - 10 000) µg in the sample acetonitrile butan-2-one (methyl ethyl ketone) 2-butoxyethanol chlorobenzene chloroform dichloromethane ethanol diethyl ether 2-ethoxyethanol butyl methacrylate methyl methacrylate 2-methoxyethanol 1-methoxypropan-2-ol methylcyclohexane 4-methylpentan- 2-one (methyl isobutyl ketone) 2-butoxyethyl acetate 2-ethoxyethyl acetate isobutyl acetate isopropyl acetate 2-methoxyethyl acetate 2-methoxy-1-methylethyl acetate methyl acetate propyl acetate vinyl acetate propan-1-ol propan-2-ol (isopropyl alcohol) carbon tetrachloride tetrachloroethene trichloroethene Range (25 - 10 000) µg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN 13649:2005 | Test procedure TSO/PB-08 issue 10 of 10.04.2024 | |
| 64 | General environment – waste gas samples collected on sorbent tubes | Cumene (2-phenylpropane, isopropylbenzene) content Range (10 - 10000) µg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN 13649:2005 | |
| 65 | General environment – waste gas samples collected on sorbent tubes | Aliphatic hydrocarbon content decane hexane heptane nonane octane pentane undecane Range (2 - 10 000) µg in the sample dodecane tridecane Range (25 - 10 000) µg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN 13649:2005 | Test procedure TSO/PB-08 issue 10 of 10.04.2024 | |
| 66 | General environment – waste gas samples collected on sorbent tubes | Aromatic hydrocarbon content benzene Range (1 - 200) µg in the sample ethylbenzene o-xylene m-xylene p-xylene styrene toluene 1,2,3-trimethylbenzene 1,2,4-trimethylbenzene 1,3,5-trimethylbenzene Range (2 - 10 000) µg in the sample propylbenzene Range (25 - 10 000) µg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN 13649:2005 | Test procedure TSO/PB-08 issue 10 of 10.04.2024 | |
| 67 | General environment – waste gas samples collected on sorbent tubes | Acetic acid content Range (25 - 10 000) µg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04323:2004 | |
| 68 | General environment – waste gas samples collected on sorbent tubes | Phenol, o-cresol, m-cresol, p-cresol content Range (2 - 1000) µg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | Principles and Methods of Assessing the Working Environment, 1999, No. 22, CIOP | PN-Z-04008-4:1999 | |
| 69 | General environment – waste gas samples collected on sorbent tubes | Concentration/Content of 2-(2-butoxyethoxy)ethanol Range (50 - 1500) µg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04399:2011 | |
| 70 | General environment – waste gas samples collected into absorbing solution | Formaldehyde content Range (0,0015 - 0,12) mg in the sample |
Spectrophotometric method | Test procedure TSO/PB-06 issue 4 of 19.12.2014 | |
| 71 | General environment – waste gas samples collected into absorbing solution | Ammonia content Range (0,04 - 4) mg in the sample |
Spectrophotometric method | PN-71/Z-04041 | |
| 72 | General environment – waste gas samples collected into absorbing solution | Methanol content Range (10 - 1000) µg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-81/Z-04028.01 | PN-Z-04008-4:1999 | |
| 73 | Workplace environment − noise | A-weighted equivalent sound level A-weighted maximum sound level Range (25 - 136) dB C-weighted peak sound pressure level (50 - 140) dB |
Direct measurement method | PN-N-01307:1994 | PN-EN ISO 9612:2011 excluding the methods covering strategies 2 and 3 – clauses 10 and 11 | |
| 74 | Workplace environment − noise | Noise exposure level normalised to: (calculated) an 8-hour daily working time average weekly working time |
PN-N-01307:1994 | PN-EN ISO 9612:2011 excluding the methods covering strategies 2 and 3 – clauses 10 and 11 | ||
| 75 | General environment - noise from installations, equipment and industrial plants | A-weighted equivalent sound level Range (25 - 136) dB |
Direct measurement method | Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023 item 1706) – excluding cl. F | |
| 76 | General environment - noise from installations, equipment and industrial plants | A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) | Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023 item 1706) – excluding cl. F | ||
| 77 | Rooms in residential, collective residence and public utility buildings - noise | A-weighted equivalent sound level A-weighted maximum sound level Range (22 - 136) dB |
Direct measurement method | PN-87/B-02156 | |
| 78 | Rooms in residential, collective residence and public utility buildings - noise | A-weighted equivalent sound level for reference time T (calculated) | PN-87/B-02156 | ||
| 79 | Rooms and open decks on ships - noise | A-weighted equivalent sound level Range (25 - 136) dB C-weighted peak sound pressure level (35 - 140) dB |
Direct measurement method | PN-ISO 2923:2001+Ap1:2014-04 | |
| 80 | Rooms and open decks on ships - noise | Equivalent sound pressure level in octave frequency bands Range from 31,5 Hz to 8 kHz Range (25 - 136) dB |
Direct measurement method | PN-ISO 2923:2001+Ap1:2014-04 | |
| 81 | Workplace environment − indoor and outdoor electric lighting | Illuminance Range (5 - 10 000) lx |
Direct measurement method | PN-83/E-04040.03 | |
| 82 | Workplace environment − indoor and outdoor electric lighting | Illuminance uniformity (calculated) | PN-83/E-04040.03 | ||
| 83 | Workplace environment − emergency lighting | Emergency lighting illuminance Range (0,5 - 500) lx |
Direct measurement method | PN-EN 1838:2013-11 | |
| 84 | Workplace environment - hand-arm vibration | Frequency-weighted r.m.s. vibration acceleration Range (0,06 - 100) m/s2 |
Direct measurement method; Sampling method | PN-EN-ISO 5349-1:2004 | PN-EN-ISO 5349-2:2004 | PN-EN-ISO 5349-2:2004/A1:2015-11 | |
| 85 | Workplace environment - hand-arm vibration | Daily exposure, expressed as the energy-equivalent for 8 hours of the vector sum of the r.m.s. frequency-weighted vibration accelerations determined for the three directional components (ahwx, ahwy, ahwz) Exposure lasting 30 minutes or less, expressed as the vector sum of the r.m.s. frequency-weighted vibration accelerations determined for the three directional components (ahwx, ahwy, ahwz) (calculated) | PN-EN-ISO 5349-1:2004 | PN-EN-ISO 5349-2:2004 | PN-EN-ISO 5349-2:2004/A1:2015-11 | ||
| 86 | Workplace environment - whole-body vibration | Frequency-weighted r.m.s. vibration acceleration Range (0,001 - 25) m/s2 |
Direct measurement method; Sampling method | PN-EN 14253+A1:2011 | |
| 87 | Workplace environment - whole-body vibration | Daily exposure, expressed as the 8-hour energy-equivalent frequency-weighted RMS vibration acceleration dominant among the vibration accelerations determined for the three directional components taking into account the appropriate coefficients (1,4awx, 1,4awy, awz) Exposure lasting 30 minutes and less, expressed as the frequency-weighted RMS vibration acceleration dominant among the vibration accelerations determined for the three directional components taking into account the appropriate coefficients (1,4awx, 1,4awy, awz) (calculated) | PN-EN 14253+A1:2011 | ||
| 88 | Workplace environment - moderate microclimate | Air temperature Range (0 - 60) °C Black globe temperature (0 - 60) °C Air humidity (20 - 90) % Air velocity (0,15 - 5,0) m/s |
Direct measurement method | PN-EN ISO 7730:2006+Ap2:2016-04 | |
| 89 | Workplace environment - moderate microclimate | PMV index PPD index (calculated) | PN-EN ISO 7730:2006+Ap2:2016-04 | ||
| 90 | Workplace environment - hot microclimate | Air temperature Range (10 - 60) °C Natural wet bulb temperature (0 - 60) °C Black globe temperature (10 - 60) °C |
Direct measurement method | PN-EN 7243:2018-01 | |
| 91 | Workplace environment - hot microclimate | WBGT index (calculated) | PN-EN 7243:2018-01 | ||
| 92 | Workplace environment - cold microclimate | Air temperature Range (-30 - 10) °C Black globe temperature (-30 - 10) °C Air humidity (20 - 90) % Air velocity (0,15 - 5,0) m/s |
Direct measurement method | PN-EN ISO 11079:2008 | |
| 93 | Workplace environment - cold microclimate | IREQmin index IREQneutral index twc index (calculated) | PN-EN ISO 11079:2008 | ||
| 94 | Workplace environment – ultrasonic noise | Equivalent sound pressure level in one-third octave bands with centre frequencies from 10 kHz to 40 kHz. Maximum sound pressure level in one-third octave bands with centre frequencies from 10 kHz to 40 kHz Range (54 - 158) dB |
Direct measurement method | PN-Z-01339:2020-12 | |
| 95 | Workplace environment – ultrasonic noise | Equivalent sound pressure level in one-third octave bands with centre frequencies from 10 kHz to 40 kHz referred to: (calculated) an 8-hour daily working time average weekly working time |
PN-Z-01339:2020-12 | ||
Reference standards (65)
PN-71/Z-04041
PN-75/Z-04037.03
PN-79/Z-04106.02
PN-81/Z-04028.01
PN-81/Z-04134.02 excluding cl. 5, 8.
PN-81/Z-04134.03 excluding cl. 5, 8.
PN-83/E-04040.03
PN-86/Z-04151/02
PN-87/B-02156
PN-87/Z-04100/03
PN-87/Z-04126/03
PN-92/Z-04227/02 excluding cl. 8.
PN-EN 13649:2005
PN-EN 14253+A1:2011
PN-EN 1838:2013-11
PN-EN 689+AC:2019-06
PN-EN 7243:2018-01
PN-EN ISO 11079:2008
PN-EN ISO 7730:2006+Ap2:2016-04
PN-EN ISO 9612:2011 excluding the methods covering strategies 2 and 3 – clauses 10 and 11
PN-EN-ISO 5349-1:2004
PN-EN-ISO 5349-2:2004
PN-EN-ISO 5349-2:2004/A1:2015-11
PN-ISO 2923:2001+Ap1:2014-04
PN-N-01307:1994
PN-Z-01339:2020-12
PN-Z-04008-4:1999
PN-Z-04008-7:2002+Az1:2004
PN-Z-04016-6:1998
PN-Z-04045-16:2010
PN-Z-04216-2:2012
PN-Z-04263-1:2012
PN-Z-04291:2003
PN-Z-04323:2004
PN-Z-04399:2011
PN-Z-04434:2011
PN-Z-04435:2011
PN-Z-04436:2011
PN-Z-04442:2023-05
PN-Z-04450:2014-08
PN-Z-04469:2025-02
PN-Z-04470:2015-10
PN-Z-04472:2015-10+Ap1:2015-12
PN-Z-04487:2017-10
PN-Z-04488:2017-10
PN-Z-04497:2018-09
PN-Z-04502:2019-10
PN-Z-04507:2022-05
PN-Z-04507:2022-05/Ap1:2022-08
PN-Z-04508:2022-05
PN-Z-04508:2022-05/Ap1:2022-08
Principles and Methods of Assessing the Working Environment 2012, No. 4 (74), pp. 117–130
Principles and Methods of Assessing the Working Environment 2021, No. 4 (110), pp. 179–189
Principles and Methods of Assessing the Working Environment, 1999, No. 22, CIOP
Principles and Methods of Assessing the Working Environment, 1999, No. 22, pp. 96-100
Principles and Methods of Assessing the Working Environment 2022, No. 2 (112), pp. 111–126
Principles and Methods of Assessing the Working Environment 2022, No. 2 (112), pp. 127–142
Test procedure TSO/PB-02 issue 1 of 17.03.2022
Test procedure TSO/PB-04 issue 7 of 01.12.2008
Test procedure TSO/PB-06 issue 4 of 19.12.2014
Test procedure TSO/PB-08 issue 10 of 10.04.2024
Test procedure TSO/PB-08 issue 10 of 10.04.2024 cl. 5, 7, 8, 9.1, 11
Test procedure TSO/PB-08 issue 10 of 10.04.2024 cl. 5, 7, 8, 9.1, 11.
Test procedure TSO/PB-14 issue 3 of 19.12.2014
Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023 item 1706) – excluding cl. F