🇵🇱 EKOMIAR S.C. PL
EnvironmentConstructionMaterials & polymers
EKOMIAR S.C. is a laboratory accredited by PCA under number AB 417 (Toruń, Poland). Its accreditation scope covers 12 test methods in the following areas: Environment, Construction, Materials & polymers. Test objects include: Workplace environment – air, Workplace environment – electromagnetic field, Workplace environment – indoor electric lighting, Workplace environment – noise. Most frequently used techniques: Direct measurement method, Gravimetric method, Direct measurement method (simplified).
At a glance
- Accreditation number: PCA AB 417
- Methods in scope: 12
- Types of test objects: 5
- Techniques used: 4
- City: Toruń, Poland
- Accreditation number
- AB 417
- Accreditation body
- PCA
- Address
- K. MAKARUK, G. DŁUŻNIEWSKA, ul. Podgórna 21/10,, 87-100 Toruń, LABORATORIUM BADAŃ ŚRODOWISKOWYCH, ul. Żółkiewskiego 37/41,
- City
- Toruń, Poland
What this laboratory tests (5)
- Workplace environment – air — 4 methods
- Workplace environment – electromagnetic field — 3 methods
- Workplace environment – indoor electric lighting — 2 methods
- Workplace environment – noise — 2 methods
- Workplace environment - electromagnetic field in the workspace from magnetotherapy devices — 1 method
Analytical techniques used (4)
- Direct measurement method — 4 methods
- Gravimetric method — 2 methods
- Direct measurement method (simplified) — 1 method
- Personal dosimetry method — 1 method
Laboratory locations
- EKOMIAR S.C. K. Makaruk, G. Dłużniewska (main site) — ul. Podgórna 21/10, 87-100 Toruń
- Environmental Testing Laboratory — ul. Żółkiewskiego 37/41, 87-100 Toruń
Certificate information
- Issue date
- 08.12.2025
- Issue no.
- 25
Accreditation scope — test methods (12)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Workplace environment – electromagnetic field | Electric field strength in the frequency range from 50 Hz up to 30 MHz Range 1 V/m - 50 kV/m, from 0,8 up to 3 GHz Range (1 - 500) V/m |
Direct measurement method | PN-T-06580-3:2002 excluding cl. 2.1.4.2 Method adapted to the regulated area | |
| 2 | Workplace environment – electromagnetic field | Magnetic flux density in the frequency range from 50 Hz up to 500 kHz Range 30 nT - 19 mT Magnetic field strength in the frequency range from 100 kHz up to 30 MHz Range (0,03 - 20) A/m |
Direct measurement method | PN-T-06580-3:2002 excluding cl. 2.1.4.2 Method adapted to the regulated area | |
| 3 | Workplace environment – electromagnetic field | Magnetic field strength in the frequency range from 800 MHz to 3 GHz (calculated) | PN-T-06580-3:2002 excluding cl. 2.1.4.2 Method adapted to the regulated area | ||
| 4 | Workplace environment - electromagnetic field in the workspace from magnetotherapy devices | Magnetic flux density: in the frequency range from 20 up to 50 Hz Range (1 μT - 19 mT) |
Direct measurement method (simplified) | Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 151–180 | |
| 5 | Workplace environment – air | Sampling for the assessment of occupational exposure to: dust agents – inhalable fraction – respirable fraction organic substances inorganic substances – respirable fraction metals and their compounds, including – inhalable fraction – respirable fraction |
Personal dosimetry method | PN-Z-04008-7:2002+Az1:2004 | |
| 6 | Workplace environment – air | Exposure index (calculated) | PN-Z-04008-7:2002+Az1:2004 | ||
| 7 | Workplace environment – air | Concentration of harmful dust agents - inhalable fraction: Apatites and phosphorites Portland cement Titanium dioxide Natural graphite Synthetic graphite Kaolin Amorphous and synthetic silica Wood dusts Flour dusts Dusts not classified according to toxicity Organic dusts of animal and plant origin, excluding wood and flour dusts Calcium sulfate (VI) (gypsum) Carbon black Coal (hard, brown) Calcium magnesium carbonate (dolomite) Range (0,2 - 20) mg/m3 |
Gravimetric method | PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08 | |
| 8 | Workplace environment – air | Concentration of harmful dust agents - respirable fraction: Apatites and phosphorites Portland cement Natural graphite Amorphous and synthetic silica Organic dusts of animal and plant origin, excluding wood and flour dusts Coal (hard, brown) Range (0,2 - 20) mg/m3 |
Gravimetric method | PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08 | |
| 9 | Workplace environment – noise | A-weighted equivalent sound level Maximum A-weighted sound level Range (30 - 134) dB C-weighted peak sound pressure level Range (40 - 137) dB |
Direct measurement method | PN-N-01307:1994 | PN-EN ISO 9612:2011 excluding the method covering strategies 2 (cl. 10) and 3 – cl. 11 | |
| 10 | Workplace environment – noise | Noise exposure level referred to: an 8-hour daily working time the average weekly working time (calculated) |
PN-N-01307:1994 | PN-EN ISO 9612:2011 excluding the method covering strategies 2 (cl. 10) and 3 – cl. 11 | ||
| 11 | Workplace environment – indoor electric lighting | Illuminance Range (20 - 9000) lx |
Direct measurement method | PN-E/83-04040.3 | PB-02 issue 3 of 20.09.2022 | |
| 12 | Workplace environment – indoor electric lighting | Illuminance uniformity (calculated) | PN-E/83-04040.3 | PB-02 issue 3 of 20.09.2022 | ||
Reference standards (11)
PB-02 issue 3 of 20.09.2022
PN-E/83-04040.3
PN-EN ISO 9612:2011 excluding the method covering strategies 2 (cl. 10) and 3 – cl. 11
PN-N-01307:1994
PN-T-06580-3:2002 excluding cl. 2.1.4.2 Method adapted to the regulated area
PN-Z-04008-7:2002+Az1:2004
PN-Z-04507:2022-05
PN-Z-04507:2022-05/Ap1:2022-08
PN-Z-04508:2022-05
PN-Z-04508:2022-05/Ap1:2022-08
Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 151–180