🇵🇱 GRUPA EKOPROJEKT Sp. z o. o. PL
EnvironmentMaterials & polymers
GRUPA EKOPROJEKT Sp. z o. o. is a laboratory accredited by PCA under number AB 409 (Bielsko-Biała, Poland). Its accreditation scope covers 223 test methods in the following areas: Environment, Materials & polymers. Test objects include: Waste gases, Automated Measuring Systems (AMS), Working environment E - air - air samples collected into an absorbi…, Waste gases, General environment E - waste gas samples. Most frequently used techniques: Direct measurement method, Spectrophotometric method, Ion chromatography with conductometric detection (IC-CD).
At a glance
- Accreditation number: PCA AB 409
- Methods in scope: 223
- Types of test objects: 43
- Techniques used: 38
- City: Bielsko-Biała, Poland
- Accreditation number
- AB 409
- Accreditation body
- PCA
- Address
- LABORATORIUM BADAŃ ŚRODOWISKA, ul. Kazimierza Wielkiego 15, 43-300 Bielsko-Biała
- City
- Bielsko-Biała, Poland
What this laboratory tests (43)
- Waste gases — 68 methods
- Automated Measuring Systems (AMS) — 22 methods
- Working environment E - air - air samples collected into an absorbing solution — 17 methods
- Waste gases, General environment E - waste gas samples — 15 methods
- Workplace environment – air — 8 methods
- Workplace environment - non-laser optical radiation — 7 methods
- Environment – electromagnetic field in the vicinity of radiocommunication and radionavigation installations (broadband measurements) — 5 methods
- General environment E - ambient air samples collected on filters and sorbent tubes, condensate samples and samples collected into absorbing solutions, Indoor spaces E - air samples collected on filters and sorbent tubes, condensate samples and samples collected into absorbing solutions — 5 methods
- Waste gases, General environment E – waste gas samples collected on filters and sorbent tubes, condensate samples and absorbing solution samples — 5 methods
- Working environment - electromagnetic field from industrial installations and equipment: - arc welding equipment - resistance welders - industrial magnetisers and demagnetisers - electrolytic installations - NMR spectrometers - dielectric heating equipment - induction heating equipment - industrial microwave furnaces, heaters and dryers - equipment for the production and processing of plastics - soldering equipment - electrical discharge machines - resistance and arc furnaces - inverters - household electrical equipment - electric vehicles and traction systems — 4 methods
- Working environment - electromagnetic field from radiocommunication and anti-theft systems: - hand-held radiotelephones, terminals and short-range wireless devices, body-worn and vehicle radio stations (radiotelephones) - anti-theft and electronic article surveillance systems - radar and radiolocation systems — 4 methods
- Workplace environment - electromagnetic field originating from equipment used in medical technology: - surgical diathermy - physiotherapeutic diathermy - magnetic resonance scanners — 4 methods
- Workplace environment E - air - air samples collected on filters — 4 methods
- Environment – electromagnetic field in the vicinity of electric power substations and power lines — 3 methods
- General environment - noise from installations and equipment and industrial plants — 3 methods
- and 28 more
Analytical techniques used (38)
- Direct measurement method — 31 methods
- Spectrophotometric method — 27 methods
- Ion chromatography with conductometric detection (IC-CD) — 11 methods
- Non-dispersive infrared spectrometry (NDIR) — 7 methods
- Gravimetric method — 6 methods
- Gas chromatography with flame ionization detection (GC-FID) — 5 methods
- High-performance liquid chromatography with fluorescence detection (HPLC-FLD) — 5 methods
- High-performance liquid chromatography with fluorescence detection (HPLC-FLD); High-performance liquid chromatography with diode array detection (HPLC-DAD) — 4 methods
- Electrochemical method — 3 methods
- Flame atomic absorption spectrometry (FAAS) — 3 methods
- High-performance liquid chromatography with diode array detection (HPLC-DAD) — 3 methods
- Condensation-adsorption method; Temperature method — 2 methods
- Continuous flame ionization detection method (FID) — 2 methods
- Paramagnetic method — 2 methods
- Thoron method — 2 methods
- and 23 more
Laboratory locations
- GRUPA EKOPROJEKT Sp. z o. o. (main site) — ul. Kazimierza Wielkiego 15, 43-300 Bielsko-Biała
- ENVIRONMENTAL TESTING LABORATORY — ul. Kazimierza Wielkiego 15
Certificate information
- Issue date
- 03.09.2026
- Issue no.
- 35
Accreditation scope — test methods (223)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Environmental Testing Laboratory | |||||
| 1 | Workplace environment – noise | A-weighted equivalent sound level, A-weighted maximum sound level, C-weighted peak sound level, Range (35 – 135) dB |
Direct measurement method | PN-N-01307:1994 | PN-EN ISO 9612:2025-11 | |
| 2 | Workplace environment – noise | Noise exposure level referred to: an 8-hour daily working time the average weekly working time (calculated) |
PN-N-01307:1994 | PN-EN ISO 9612:2025-11 | ||
| 3 | Workplace environment – ultrasonic noise | Equivalent sound pressure level in one-third octave bands with centre frequencies from 10 kHz to 40 kHz Maximum sound pressure level in one-third octave bands with centre frequencies from 10 kHz to 40 kHz Range (54 – 139) dB |
Direct measurement method | PN-Z-01339:2020-12 | |
| 4 | Workplace environment – ultrasonic noise | Equivalent sound pressure level in one-third octave bands with centre frequencies from 10 kHz to 40 kHz referred to: – the 8-hour daily working time – the average weekly working time (calculated) | PN-Z-01339:2020-12 | ||
| 5 | General environment - noise from installations and equipment and industrial plants | A-weighted equivalent sound pressure level Range (25 – 135) dB |
Direct measurement method | Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023, item 1706) | PN-SO 9613-2:2002 | |
| 6 | General environment - noise from installations and equipment and industrial plants | A-weighted equivalent sound level for the time T expressed by the indicator LAeqD and LAeqN (calculated) | Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023, item 1706) | PN-SO 9613-2:2002 | ||
| 7 | General environment - noise from installations and equipment and industrial plants | A-weighted equivalent sound level for time T expressed by the indicator LAeqD and LAeqN | Calculation method | Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023, item 1706) | PN-SO 9613-2:2002 | |
| 8 | Machinery and equipment – noise | Sound pressure level weighted with the characteristic frequency weighting A Range (25 – 135) dB |
Direct measurement method | PN-EN ISO 3744:2011 excluding cl. 8.3 | PN-EN ISO 3746:2011+Ap1:2017-09 excluding cl. 8.4 | |
| 9 | Machinery and equipment – noise | Sound power level (calculated) | PN-EN ISO 3744:2011 excluding cl. 8.3 | PN-EN ISO 3746:2011+Ap1:2017-09 excluding cl. 8.4 | ||
| 10 | Workplace environment - hand-arm vibration | Frequency-weighted r.m.s. vibration acceleration Range (0,05 – 100) m/s2 |
Direct measurement method | PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11 | |
| 11 | Workplace environment - hand-arm vibration | Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the vector sum of the r.m.s. frequency-corrected vibration accelerations determined for three directional components (ahwx, ahwy, ahwz), Exposure lasting 30 minutes or less, expressed as the vector sum of the r.m.s. frequency-weighted vibration accelerations determined for three directional components (ahwx, ahwy, ahwz) (calculated) | PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11 | ||
| 12 | Workplace environment − whole-body vibration | Frequency-weighted r.m.s. vibration acceleration Range (0,02 – 50) m/s2 |
Direct measurement method | PN-EN 14253+A1:2011 | |
| 13 | Workplace environment − whole-body vibration | Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the r.m.s. frequency-corrected vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz), Exposure lasting 30 minutes or less, expressed as the r.m.s. frequency-weighted vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz) (calculated) | PN-EN 14253+A1:2011 | ||
| 14 | Workplace environment − moderate microclimate | Air temperature Range (10 – 30) °C Black globe temperature Range (10 – 40) °C Air humidity Range (30 – 90) % Air velocity Range (0,15 – 4,8) m/s |
Direct measurement method | PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04 | |
| 15 | Workplace environment − moderate microclimate | PMV index, PPD index (calculated) | PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04 | ||
| 16 | Workplace environment − moderate microclimate | Page version: A | |||
| 17 | Workplace environment − cold microclimate | Air temperature Range (-20 – 10) °C Black globe temperature Range (- 20 – 10) °C Air humidity Range (30 – 90) % Air velocity Range (0,15 – 4,8) m/s |
Direct measurement method | PN-EN ISO 11079:2008 | |
| 18 | Workplace environment − cold microclimate | IREQmin index, IREQneutral index, twc index (calculated) | PN-EN ISO 11079:2008 | ||
| 19 | Workplace environment − hot microclimate | Air temperature Range (15 – 50) °C Natural wet bulb temperature Range (15 – 40) °C Black globe temperature Range (15 – 50) °C |
Direct measurement method | PN-EN ISO 7243:2018-01 | PN-EN ISO 7243:2018-01/Ap2:2020-04 | |
| 20 | Workplace environment − hot microclimate | WBGT index, WBGTeff index (calculated) | PN-EN ISO 7243:2018-01 | PN-EN ISO 7243:2018-01/Ap2:2020-04 | ||
| 21 | Workplace environment | Illuminance, Range (0,5 – 10000) lx |
PB-65 issue 3 of 19.06.2023 | ||
| 22 | indoors | Direct measurement method | PB-65 issue 3 of 19.06.2023 | ||
| 23 | indoors | Illuminance uniformity (calculated) | PB-65 issue 3 of 19.06.2023 | ||
| 24 | Workplace environment - outdoor electric lighting, General environment - outdoor electric lighting | Illuminance, Range (0,5 – 10000) lx |
Direct measurement method | PB-92 issue 2 of 19.06.2023 | |
| 25 | Workplace environment - outdoor electric lighting, General environment - outdoor electric lighting | Illuminance uniformity (calculated) | PB-92 issue 2 of 19.06.2023 | ||
| 26 | Workplace environment – energy expenditure | Air temperature Range (0 – 60) °C Air flow Range (10 – 60) dm 3/min |
Direct measurement method | PB-46 issue 3 of 05.04.2023 | |
| 27 | Workplace environment – energy expenditure | Energy expenditure (calculated) | PB-46 issue 3 of 05.04.2023 | ||
| 28 | Workplace environment - non-laser optical radiation | Effective irradiance, UVA, UVB and UVC in the spectral range (180 – 400) nm, Measurement range (8,00*10-4 – 10), W/m2 | Direct measurement method (method A) | PN-EN 14255-1:2010 | |
| 29 | Workplace environment - non-laser optical radiation | Effective irradiation UVA, UVB and UVC in the spectral range (180 – 400) nm (calculated) | PN-EN 14255-1:2010 | ||
| 30 | Workplace environment - non-laser optical radiation | Irradiance of UVA in the spectral range (315 – 400) nm, Measurement range (2,50*10-4 – 8,75*102) W/m2 | Direct measurement method (method M) | PN-EN 14255-1:2010 | |
| 31 | Workplace environment - non-laser optical radiation | Radiant exposure of UVA in the spectral range (315 – 400) nm (calculated) | PN-EN 14255-1:2010 | ||
| 32 | Workplace environment - non-laser optical radiation | Effective irradiance, VIS in the spectral range (315 – 700) nm, Measurement range (2,00*10-4 – 3,00*103) W/m2 | Direct measurement method (method O) | PN-EN 14255-2:2010 | |
| 33 | Workplace environment - non-laser optical radiation | Effective VIS luminance in the spectral range (400 – 700) nm (calculated) | PN-T-05687:2002 cl. 2.5.5 | ||
| 34 | Workplace environment - non-laser optical radiation | Irradiance of IRA and IRB in the spectral range (770 – 3000) nm, Measurement range (9,00*10-1 – 4,00*103) W/m2 | Direct measurement method (method R) | PN-EN 14255-2:2010 | |
| 35 | Working environment - electromagnetic field from industrial installations and equipment: - arc welding equipment - resistance welders - industrial magnetisers and demagnetisers - electrolytic installations - NMR spectrometers - dielectric heating equipment - induction heating equipment - industrial microwave furnaces, heaters and dryers - equipment for the production and processing of plastics - soldering equipment - electrical discharge machines - resistance and arc furnaces - inverters - household electrical equipment - electric vehicles and traction systems | Magnetic flux density (0 Hz) Range (0,21 – 1000) mT in the frequency range from 5 Hz up to 500 kHz Range (0,15 –18750) μT |
Direct measurement method | PN-T-06580-3:2002 Method adapted to the regulated area | Working instruction No. IR-C1 issue 4 of 21.04.2024 | |
| 36 | Working environment - electromagnetic field from industrial installations and equipment: - arc welding equipment - resistance welders - industrial magnetisers and demagnetisers - electrolytic installations - NMR spectrometers - dielectric heating equipment - induction heating equipment - industrial microwave furnaces, heaters and dryers - equipment for the production and processing of plastics - soldering equipment - electrical discharge machines - resistance and arc furnaces - inverters - household electrical equipment - electric vehicles and traction systems | Electric field strength: in the frequency range from 5 Hz up to 90 GHz Range (1– 50 000) V/m |
Direct measurement method | PN-T-06580-3:2002 Method adapted to the regulated area | Working instruction No. IR-C1 issue 4 of 21.04.2024 | |
| 37 | Working environment - electromagnetic field from industrial installations and equipment: - arc welding equipment - resistance welders - industrial magnetisers and demagnetisers - electrolytic installations - NMR spectrometers - dielectric heating equipment - induction heating equipment - industrial microwave furnaces, heaters and dryers - equipment for the production and processing of plastics - soldering equipment - electrical discharge machines - resistance and arc furnaces - inverters - household electrical equipment - electric vehicles and traction systems | Magnetic field strength: in the frequency range From 100 kHz up to 1 GHz Range (0,010 – 16) A/m |
Direct measurement method | PN-T-06580-3:2002 Method adapted to the regulated area | Working instruction No. IR-C1 issue 4 of 21.04.2024 | |
| 38 | Working environment - electromagnetic field from industrial installations and equipment: - arc welding equipment - resistance welders - industrial magnetisers and demagnetisers - electrolytic installations - NMR spectrometers - dielectric heating equipment - induction heating equipment - industrial microwave furnaces, heaters and dryers - equipment for the production and processing of plastics - soldering equipment - electrical discharge machines - resistance and arc furnaces - inverters - household electrical equipment - electric vehicles and traction systems | Magnetic field strength: in the frequency range from 800 MHz up to 90 GHz (calculated) |
PN-T-06580-3:2002 Method adapted to the regulated area | Working instruction No. IR-C1 issue 4 of 21.04.2024 | ||
| 39 | Working environment - electromagnetic field from radiocommunication and anti-theft systems: - hand-held radiotelephones, terminals and short-range wireless devices, body-worn and vehicle radio stations (radiotelephones) - anti-theft and electronic article surveillance systems - radar and radiolocation systems | Magnetic flux density (0 Hz) Range (0,21 – 1000) mT in the frequency range from 5 Hz up to 500 kHz Range (0,15 –18750) μT |
Direct measurement method | PN-T-06580-3:2002 Method adapted to the regulated area | Working instruction No. IR-C1 issue 4 of 21.04.2024 | |
| 40 | Working environment - electromagnetic field from radiocommunication and anti-theft systems: - hand-held radiotelephones, terminals and short-range wireless devices, body-worn and vehicle radio stations (radiotelephones) - anti-theft and electronic article surveillance systems - radar and radiolocation systems | Electric field strength: in the frequency range from 5 Hz up to 90 GHz Range (1– 50 000) V/m |
Direct measurement method | PN-T-06580-3:2002 Method adapted to the regulated area | Working instruction No. IR-C1 issue 4 of 21.04.2024 | |
| 41 | Working environment - electromagnetic field from radiocommunication and anti-theft systems: - hand-held radiotelephones, terminals and short-range wireless devices, body-worn and vehicle radio stations (radiotelephones) - anti-theft and electronic article surveillance systems - radar and radiolocation systems | Magnetic field strength: in the frequency range From 100 kHz up to 1 GHz Range (0,010 – 16) A/m |
Direct measurement method | PN-T-06580-3:2002 Method adapted to the regulated area | Working instruction No. IR-C1 issue 4 of 21.04.2024 | |
| 42 | Working environment - electromagnetic field from radiocommunication and anti-theft systems: - hand-held radiotelephones, terminals and short-range wireless devices, body-worn and vehicle radio stations (radiotelephones) - anti-theft and electronic article surveillance systems - radar and radiolocation systems | Magnetic field strength: in the frequency range from 800 MHz up to 90 GHz (calculated) |
PN-T-06580-3:2002 Method adapted to the regulated area | Working instruction No. IR-C1 issue 4 of 21.04.2024 | ||
| 43 | Workplace environment - electromagnetic field originating from equipment used in medical technology: - surgical diathermy - physiotherapeutic diathermy - magnetic resonance scanners | Magnetic flux density (0 Hz) Range (0,21 – 1000) mT in the frequency range from 5 Hz up to 500 kHz Range (0,15 – 18750) μT |
Direct measurement method | PN-T-06580-3:2002 Method adapted to the regulated area | Working instruction No. IR-C1 issue 4 of 21.04.2024 | |
| 44 | Workplace environment - electromagnetic field originating from equipment used in medical technology: - surgical diathermy - physiotherapeutic diathermy - magnetic resonance scanners | Electric field strength: in the frequency range from 5 Hz up to 90 GHz Range (1 – 50 000) V/m |
Direct measurement method | PN-T-06580-3:2002 Method adapted to the regulated area | Working instruction No. IR-C1 issue 4 of 21.04.2024 | |
| 45 | Workplace environment - electromagnetic field originating from equipment used in medical technology: - surgical diathermy - physiotherapeutic diathermy - magnetic resonance scanners | Magnetic field strength: in the frequency range From 100 kHz up to 1 GHz Range (0,010 – 16) A/m |
Direct measurement method | PN-T-06580-3:2002 Method adapted to the regulated area | Working instruction No. IR-C1 issue 4 of 21.04.2024 | |
| 46 | Workplace environment - electromagnetic field originating from equipment used in medical technology: - surgical diathermy - physiotherapeutic diathermy - magnetic resonance scanners | Magnetic field strength: in the frequency range from 800 MHz up to 90 GHz (calculated) |
PN-T-06580-3:2002 Method adapted to the regulated area | Working instruction No. IR-C1 issue 4 of 21.04.2024 | ||
| 47 | Workplace environment - electromagnetic field in the workspace during the use of power systems and AC electrical supply installations in the power industry | Electric field strength: in the frequency range from 45 Hz up to 55 Hz Range (0,10 – 50) kV/m Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the legally regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (consolidated text: Journal of Laws of 2018, item 331). |
Direct measurement method | Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 91–150 | |
| 48 | Workplace environment - electromagnetic field in the workspace during the use of power systems and AC electrical supply installations in the power industry | Magnetic flux density: in the frequency range from 45 Hz up to 55 Hz Range (1,0 –18750) μT Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the legally regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (consolidated text: Journal of Laws of 2018, item 331). |
Direct measurement method | Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 91–150 | |
| 49 | Workplace environment - electromagnetic field in the workspace during the use of power systems and AC electrical supply installations in the power industry | Magnetic field strength in the frequency range from 45 Hz to 55 Hz (calculated) Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the legally regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (consolidated text: Journal of Laws of 2018, item 331). |
Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 91–150 | ||
| 50 | Workplace environment - electromagnetic field in the workspace during the use of magnetotherapy devices | Magnetic flux density: in the frequency range from 20 Hz up to 50 Hz Range (15 – 1600) μT Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the legally regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (consolidated text: Journal of Laws of 2018, item 331). |
Direct measurement method (simplified) | Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 151–180 | |
| 51 | Workplace environment - electromagnetic field in the workspace during the use of magnetotherapy devices | Magnetic field strength in the frequency range from 20 Hz to 50 Hz (calculated) Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the legally regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (consolidated text: Journal of Laws of 2018, item 331). |
Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 151–180 | ||
| 52 | Workplace environment – electromagnetic field in the workspace during the use of transmitting devices of radiocommunication systems (mobile telephony base stations, broadcasting and radiocommunication systems – radio, television) | Electric field strength: in the frequency range from 200 kHz up to 90 GHz Range (1 – 1000) V/m Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the legally regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (consolidated text: Journal of Laws of 2018, item 331). |
Direct measurement method | Principles and Methods of Assessing the Working Environment 2017, No. 2 (92), pp. 89–131 | |
| 53 | Workplace environment – electromagnetic field in the workspace during the use of transmitting devices of radiocommunication systems (mobile telephony base stations, broadcasting and radiocommunication systems – radio, television) | Magnetic field strength: in the frequency range from 200 kHz up to 1 GHz Range (0,010 – 16) A/m Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the legally regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (consolidated text: Journal of Laws of 2018, item 331). |
Direct measurement method | Principles and Methods of Assessing the Working Environment 2017, No. 2 (92), pp. 89–131 | |
| 54 | Workplace environment – electromagnetic field in the workspace during the use of transmitting devices of radiocommunication systems (mobile telephony base stations, broadcasting and radiocommunication systems – radio, television) | Magnetic field strength: in the frequency range from 0,8 GHz up to 90 GHz (calculated) Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the legally regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (consolidated text: Journal of Laws of 2018, item 331). |
Principles and Methods of Assessing the Working Environment 2017, No. 2 (92), pp. 89–131 | ||
| 55 | Environment – electromagnetic field in the vicinity of electric power substations and power lines | Electric field strength in the frequency range 50 Hz Range (0,10 – 50) kV/m Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the legally regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Direct measurement method | Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630) | |
| 56 | Environment – electromagnetic field in the vicinity of electric power substations and power lines | Magnetic flux density in the frequency range 50 Hz Range (1,0 – 18750) μT Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the legally regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Direct measurement method | Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630) | |
| 57 | Environment – electromagnetic field in the vicinity of electric power substations and power lines | Magnetic field strength in the frequency range 50 Hz (calculated) Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the legally regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630) | ||
| 58 | Environment – electromagnetic field in the vicinity of radiocommunication and radionavigation installations (broadband measurements) | Electric field strength: in the frequency range from 100 kHz up to 3 GHz Range (0,9 – 1300) V/m in the frequency range from 0,3 GHz up to 90 GHz Range (0,8 – 400) V/m Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the legally regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Direct measurement method | Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630) | |
| 59 | Environment – electromagnetic field in the vicinity of radiocommunication and radionavigation installations (broadband measurements) | Magnetic field strength: in the frequency range from 300 kHz up to 30 MHz Range (0,011 – 16) A/m in the frequency range from 30 MHz up to 1 GHz Range (0,011 – 8,8) A/m Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the legally regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Direct measurement method | Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630) | |
| 60 | Environment – electromagnetic field in the vicinity of radiocommunication and radionavigation installations (broadband measurements) | Magnetic field strength: in the frequency range from 10 MHz up to 90 GHz (calculated) Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the legally regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Clause 3 of the Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630) | ||
| 61 | Environment – electromagnetic field in the vicinity of radiocommunication and radionavigation installations (broadband measurements) | Magnetic flux density: in the frequency range from 5 Hz up to 500 kHz Range 17 nT – 19 mT Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the legally regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Direct measurement method | Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630) | |
| 62 | Environment – electromagnetic field in the vicinity of radiocommunication and radionavigation installations (broadband measurements) | Magnetic field strength: in the frequency range from 5 Hz up to 500 kHz (calculated) Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the legally regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630) | ||
| 63 | Environment – electromagnetic field in the vicinity of radar installations (broadband measurements) | Electric field strength: in the frequency range from 0,1 MHz up to 90 GHz Range (0,8 – 400) V/m Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the legally regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Direct measurement method | Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630) | |
| 64 | Environment – electromagnetic field in the vicinity of radar installations (broadband measurements) | Magnetic field strength: in the frequency range from 10 MHz up to 90 GHz (calculated) Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the legally regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Clause 3 of the Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022, item 2630) | ||
| 65 | Workplace environment – air | Sampling for the assessment of occupational exposure to: dust agents inhalable fraction respirable fraction organic substances, including inhalable fraction inorganic substances, including inhalable fraction respirable fraction thoracic fraction metals and their compounds, including inhalable fraction respirable fraction asbestos respirable fibres man-made mineral fibres, excluding refractory ceramic fibres inhalable fraction respirable fibres |
Personal dosimetry method | PN-Z-04008-7:2002 + Az1:2004 | |
| 66 | Workplace environment – air | Exposure index (calculated) | PN-Z-04008-7:2002 + Az1:2004 | ||
| 67 | Workplace environment – air | Concentration of harmful dust agents - inhalable fraction Apatites and phosphorites Petroleum bitumen Portland cement Titanium dioxide Natural graphite Synthetic graphite Kaolin Amorphous and synthetic silica Wood dusts Flour dusts Dusts not classified according to toxicity Organic dusts of animal and plant origin, excluding wood and flour dusts Calcium sulfate (VI) (gypsum) Carbon black Talc Coal (hard, brown) Calcium magnesium carbonate (dolomite) Silicon carbide (non-fibrous) Man-made mineral fibres excluding refractory ceramic fibres Range (0,19 – 20) mg/m3 |
Gravimetric method | PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08 | |
| 68 | Workplace environment – air | Concentration of dust harmful to health - respirable fraction Apatites and phosphorites Portland cement Natural graphite Amorphous and synthetic silica Organic dusts of animal and plant origin, excluding wood and flour dusts Talc Coal (hard, brown) Range (0,1 – 4,0) mg/m3 |
Gravimetric method | PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08 | |
| 69 | Workplace environment – air | Carbon monoxide concentration Range (2,3 – 234) mg/m3 Range (1,98 – 201) ppm |
Electrochemical method | PB-01-1 issue 1 of 05.04.2023 | |
| 70 | Workplace environment – air | Carbon dioxide concentration Range (900 – 54000) mg/m3 Range (493 – 29570) ppm |
Infrared spectrometry method (IR) | PB-01-1 issue 1 of 05.04.2023 | |
| 71 | Workplace environment – air | Nitrogen oxide concentration Range (0,25 – 5,0) mg/m3 Range (0,2 – 4,0) ppm |
Electrochemical method | PB-01-1 issue 1 of 05.04.2023 | |
| 72 | Workplace environment – air | Nitrogen dioxide concentration Range (0,07 – 3,0) mg/m3 Range (0,0366 – 1,57) ppm |
Electrochemical method | PB-01-1 issue 1 of 05.04.2023 | |
| 73 | Work environment – air - air samples collected in a plastic bag | Concentration / content of dinitrogen oxide Range (9 – 180 mg/m3) |
Non-dispersive infrared spectrometry (NDIR) | PB-01-2 issue 1 of 24.02.2026 | |
| 74 | Workplace environment – air – air samples collected on filters | Number concentration / content: asbestos fibres refractory ceramic fibres refractory ceramic fibres in a mixture with other man-made mineral fibres respirable man-made mineral fibres, except refractory ceramic fibres respirable fibres of fibrous silicon carbide Range (0,001 – 2) fibres/cm3 Range (981 – 770000) fibres/sample |
Phase-contrast optical microscopy method | NIOSH 7400, Issue 3 | |
| 75 | Working environment E – air – air samples collected on filters and sorbent tubes, condensate samples and samples collected into absorbing solutions | Concentration / content of organic compounds Regulated area: Flexible scope of accreditation E
E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body. |
High-performance liquid chromatography with fluorescence detection (HPLC-FLD) | Standards, test procedures | |
| 76 | Working environment E – air – air samples collected on filters and sorbent tubes, condensate samples and samples collected into absorbing solutions | Concentration / content of organic compounds Regulated area: Flexible scope of accreditation E
E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body. |
High-performance liquid chromatography with diode array detection (HPLC-DAD) | Standards, test procedures | |
| 77 | Work environment E – air – air samples collected on filters and in sorbent tubes | Concentration / content of polycyclic aromatic hydrocarbons: Regulated area: Flexible scope of accreditation E
E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body. |
High-performance liquid chromatography with fluorescence detection (HPLC-FLD) | Standards | |
| 78 | Workplace environment E – air – air samples collected on filters | Concentration / content of diisocyanates expressed as NCO group, Diisocyanates – expressed as group, NCO (sum of concentrations/contents of isocyanate functional groups of diisocyanate compounds) Regulated area: Flexible scope of accreditation E
E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body. |
High-performance liquid chromatography with fluorescence detection (HPLC-FLD) | Standards, test procedures | |
| 79 | Working environment E - air - air samples collected on filters, on sorbent tubes, condensates and into an absorbing solution | Concentration / content of organic and inorganic compounds Regulated area: Flexible scope of accreditation E
E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body. |
Ion chromatography with conductometric detection (IC-CD) | Standards, test procedures | |
| 80 | Working environment E - air - air samples collected on filters, on sorbent tubes, condensates and into an absorbing solution | Concentration / content of amines Regulated area: Flexible scope of accreditation E
E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body. |
Ion chromatography with conductometric detection (IC-CD) | Standards, test procedures | |
| 81 | Work environment E - air - air samples collected on sorbent tubes - air samples collected in a plastic bag | Concentration / content of organic substances Regulated area: Flexible scope of accreditation E
E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body. |
Gas chromatography with flame ionization detection (GC-FID) | Standards | |
| 82 | Workplace environment E - air - air samples collected on filters | Concentration / content of metals and their compounds Regulated area: Flexible scope of accreditation E
E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body. |
Flame atomic absorption spectrometry (FAAS) | Standards, test procedures | |
| 83 | Workplace environment E - air - air samples collected on filters | Concentration / content of crystalline silica respirable fraction Regulated area: Flexible scope of accreditation E
E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body. |
Fourier transform infrared spectrometry (FT-IR) | Principles and Methods of Assessing the Working Environment 2012, issue 4 (74), pp. 117-130 | |
| 84 | Workplace environment E - air - air samples collected on filters | Concentration / content of highly refined mineral oils excluding metalworking fluids inhalable fraction Regulated area: Flexible scope of accreditation E
E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body. |
Fourier transform infrared absorption spectrometry method (FT-IR) | PN-Z-04108-5:2006 | |
| 85 | Working environment E - air - air samples collected into an absorbing solution | Ammonia concentration / content Regulated area: Flexible scope of accreditation E
E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body. |
Spectrophotometric method | PN-71/Z-04041 | |
| 86 | Working environment E - air - air samples collected into an absorbing solution | Hydrogen chloride concentration / content Regulated area: Flexible scope of accreditation E
E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body. |
Turbidimetric method | PN-93/Z-04225/03 | |
| 87 | Working environment E - air - air samples collected into an absorbing solution | Concentration / content of phenol (hydroxybenzene, carbolic acid) Regulated area: Flexible scope of accreditation E
E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body. |
Spectrophotometric method | PN-70/Z-04044 | |
| 88 | Working environment E - air - air samples collected into an absorbing solution | Concentration / content of formaldehyde (formic aldehyde, methanal, formalin) Regulated area: Flexible scope of accreditation E
E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body. |
Spectrophotometric method | PN-76/Z-04045/02 | |
| 89 | Working environment E - air - air samples collected into an absorbing solution | Concentration / content of nitrogen monoxide and nitrogen dioxide Regulated area: Flexible scope of accreditation E
E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body. |
Spectrophotometric method | PN-Z-04009-11 | |
| 90 | Working environment E - air - air samples collected into an absorbing solution | Nitric acid concentration (calculated) Regulated area: Flexible scope of accreditation E
E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body. |
PN-Z-04009-11 | ||
| 91 | Working environment E - air - air samples collected into an absorbing solution | Concentration / content of phosphoric (V) acid (orthophosphoric acid) Regulated area: Flexible scope of accreditation E
E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body. |
Spectrophotometric method | PN-Z-04073-1 | |
| 92 | Working environment E - air - air samples collected into an absorbing solution | Concentration / content of tetraphosphorus decaoxide (phosphorus pentoxide, diphosphorus pentaoxide, phosphoric (V) acid anhydride, orthophosphoric (V) acid anhydride, phosphorus decaoxide) Regulated area: Flexible scope of accreditation E
E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body. |
Spectrophotometric method | PN-Z-04073-1 | |
| 93 | Working environment E - air - air samples collected into an absorbing solution | Concentration / content of ozone Regulated area: Flexible scope of accreditation E
E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body. |
Spectrophotometric method | PN-Z-04007-2 | |
| 94 | Working environment E - air - air samples collected into an absorbing solution | Chlorine concentration / content Regulated area: Flexible scope of accreditation E
E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body. |
Spectrophotometric method | PN-75/Z-04037/03 | |
| 95 | Working environment E - air - air samples collected into an absorbing solution | Concentration / content of chlorine dioxide Regulated area: Flexible scope of accreditation E
E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body. |
Spectrophotometric method | PN-75/Z-04037/03 | |
| 96 | Working environment E - air - air samples collected into an absorbing solution | Concentration / content of hydrogen peroxide (hydrogen dioxide) Regulated area: Flexible scope of accreditation E
E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body. |
Spectrophotometric method | Principles and Methods of Assessing the Working Environment | |
| 97 | Working environment E - air - air samples collected into an absorbing solution | Concentration / content of hydrogen peroxide (hydrogen dioxide) Regulated area: Flexible scope of accreditation E
E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body. |
Spectrophotometric method | PN-Z-04548:2023-03 | |
| 98 | Working environment E - air - air samples collected into an absorbing solution | Concentration / content of fluorides expressed as F− Regulated area: Flexible scope of accreditation E
E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body. |
Spectrophotometric method | PN-75/Z-04093/02 | |
| 99 | Working environment E - air - air samples collected into an absorbing solution | Concentration / content of hydrogen fluoride (hydrofluoric acid) Regulated area: Flexible scope of accreditation E
E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body. |
Spectrophotometric method | PN-75/Z-04093/02 | |
| 100 | Working environment E - air - air samples collected into an absorbing solution | Concentration / content of sulphur dioxide Regulated area: Flexible scope of accreditation E
E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body. |
Spectrophotometric method | PN-Z-04015-12 | |
| 101 | Working environment E - air - air samples collected into an absorbing solution | Hydrogen sulphide concentration / content Regulated area: Flexible scope of accreditation E
E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body. |
Spectrophotometric method | PN-Z-04015-13 | |
| 102 | Workplace environment E - air - air samples collected on filters | Concentration / content of chromium (VI) compounds - expressed as Cr (VI) Regulated area: Flexible scope of accreditation E
E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body. |
Spectrophotometric method | PN-87/Z-04126/03 | |
| 103 | General environment E - ambient air samples collected on filters and sorbent tubes, condensate samples and samples collected into absorbing solutions, Indoor spaces E - air samples collected on filters and sorbent tubes, condensate samples and samples collected into absorbing solutions | Content of organic compounds Regulated area: Flexible scope of accreditation E
E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body. |
High-performance liquid chromatography with fluorescence detection (HPLC-FLD); High-performance liquid chromatography with diode array detection (HPLC-DAD) | Standards, test procedures | |
| 104 | General environment E - ambient air samples collected on filters and sorbent tubes, condensate samples and samples collected into absorbing solutions, Indoor spaces E - air samples collected on filters and sorbent tubes, condensate samples and samples collected into absorbing solutions | Content of organic compounds Regulated area: Flexible scope of accreditation E
E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body. |
High-performance liquid chromatography with diode array detection (HPLC-DAD) | Standards, test procedures | |
| 105 | General environment E - ambient air samples collected on filters and sorbent tubes, condensate samples and samples collected into absorbing solutions, Indoor spaces E - air samples collected on filters and sorbent tubes, condensate samples and samples collected into absorbing solutions | Isocyanate content Regulated area: Flexible scope of accreditation E
E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body. |
High-performance liquid chromatography with fluorescence detection (HPLC-FLD) | Standards, test procedures | |
| 106 | General environment E - ambient air samples collected on filters and sorbent tubes, Indoor spaces E - air samples collected on filters and sorbent tubes | Content of polycyclic aromatic hydrocarbons Regulated area: Flexible scope of accreditation E
E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body. |
High-performance liquid chromatography with fluorescence detection (HPLC-FLD); High-performance liquid chromatography with diode array detection (HPLC-DAD) | Standards | |
| 107 | General environment E - ambient air samples collected on filters and sorbent tubes, condensate samples and samples collected into absorbing solutions, Indoor spaces E - air samples collected on filters and sorbent tubes, condensate samples and samples collected into absorbing solutions | Content of organic and inorganic compounds Regulated area: Flexible scope of accreditation E
E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body. |
Ion chromatography with conductometric detection (IC-CD) | Standards, test procedures | |
| 108 | General environment E - ambient air samples collected on filters and sorbent tubes, condensate samples and samples collected into absorbing solutions, Indoor spaces E - air samples collected on filters and sorbent tubes, condensate samples and samples collected into absorbing solutions | Amine content Regulated area: Flexible scope of accreditation E
E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body. |
Ion chromatography with conductometric detection (IC-CD) | Standards, test procedures | |
| 109 | General environment E - ambient air samples collected on sorbent tubes - ambient air samples collected in a plastic bag, Indoor spaces E - air samples collected on sorbent tubes - air samples collected in a plastic bag | Content of organic substances Regulated area: Flexible scope of accreditation E
E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body. |
Gas chromatography with flame ionization detection (GC-FID) | Standards | |
| 110 | Automated Measuring Systems (AMS) | Annual surveillance test (AST) for: dust, NO, NOx, O2, CO2, CO, SO2, H2O, HCl, HF, Hg, concentration of organic substances in the form of gases and vapours expressed as total gaseous organic carbon Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
PN-EN 14181:2015 | ||
| 111 | Automated Measuring Systems (AMS) | Calibration (QAL2) for: dust, NO, NOx, O2, CO2, CO, SO2, H2O, HCl, HF, Hg, concentration of organic substances in the form of gases and vapours expressed as total gaseous organic carbon Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
PN-EN 14181:2015 | ||
| 112 | Automated Measuring Systems (AMS) | Water vapour concentration (H2O) Range (23 – 250) g/m3 Range (3 – 40) % Range (3,14 – 57,41) % Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Condensation-adsorption method; Temperature method | PN-EN 14790:2017-04 | |
| 113 | Automated Measuring Systems (AMS) | Dust concentration Range (0,001 – 5) g/m3 Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Gravimetric method | PN-Z-04030-7:1994 | |
| 114 | Automated Measuring Systems (AMS) | Dust concentration Range (0,5 – 50) mg/m3 Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Gravimetric method | PN-EN 13284-1:2018-2 | |
| 115 | Automated Measuring Systems (AMS) | Concentration of nitrogen oxides, nitrogen monoxide NOx (1,4 – 2050) mg/m3 NO (0,7 – 1340) mg/m3 Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Chemiluminescence method CLD | PN-EN 14792:2017-04 | |
| 116 | Automated Measuring Systems (AMS) | Oxygen concentration Range (1 – 20,9) % Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Paramagnetic method | PN-EN 14789:2017-04 | |
| 117 | Automated Measuring Systems (AMS) | Carbon dioxide concentration Range (0,1– 25) % Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Non-dispersive infrared spectrometry (NDIR) | ISO 12039:2019 | |
| 118 | Automated Measuring Systems (AMS) | Carbon monoxide concentration Range (0,8 – 6250) mg/m3 Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Non-dispersive infrared spectrometry (NDIR) | PN-EN 15058:2017-04 | |
| 119 | Automated Measuring Systems (AMS) | Concentration of organic substances in the form of gases and vapours expressed as total gaseous organic carbon Range (1,0 – 1000) mg/m3 Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Continuous flame ionization detection method (FID) | PN-EN 12619:2013-05 | |
| 120 | Automated Measuring Systems (AMS) | Concentration of sulphur dioxide(SO2) Range (0,17 – 2400) mg/m3 Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Ion chromatography with conductometric detection (IC-CD) | PN-EN 14791:2017-04 | |
| 121 | Automated Measuring Systems (AMS) | Sulphur dioxide concentration (SO2) Range (1,00 – 2100) mg/m3 Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Thoron method | PN-EN 14791:2017-04 | |
| 122 | Automated Measuring Systems (AMS) | Hydrogen chloride concentration (HCl) Range (0,087 – 200) mg/m3 Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Ion chromatography with conductometric detection (IC-CD) | PN-EN 1911:2011 | |
| 123 | Automated Measuring Systems (AMS) | Hydrogen chloride concentration (HCl) Range (1,0 – 200) mg/m3 Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Spectrophotometric method | PN-EN 1911:2011 | |
| 124 | Automated Measuring Systems (AMS) | Concentration of hydrogen fluoride (HF) Range (0,045 – 200) mg/m3 Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Ion chromatography with conductometric detection (IC-CD) | ISO 15713:2006 CEN/TS 17340:2020 | |
| 125 | Automated Measuring Systems (AMS) | Sampling for determination of total mercury concentration Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
PN-EN 13211:2006 | ||
| 126 | Automated Measuring Systems (AMS) | Annual surveillance test (AST) for: N2O, NH3, CH4, HCHO | PN-EN 14181:2015 | ||
| 127 | Automated Measuring Systems (AMS) | Calibration (QAL2) for: N2O, NH3, CH4, HCHO | PN-EN 14181:2015 | ||
| 128 | Automated Measuring Systems (AMS) | Nitrous oxide concentration Range (1,6 – 150) mg/m3 |
Non-dispersive infrared spectrometry (NDIR) | PN-EN ISO 21258:2010 | |
| 129 | Automated Measuring Systems (AMS) | Ammonia concentration Range (0,04 – 200) mg/m3 |
Ion chromatography with conductometric detection (IC-CD) | PN-EN ISO 21877:2020-03 | |
| 130 | Automated Measuring Systems (AMS) | Methane concentration Range (0,0012 – 0,3) % |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN ISO 25139:2011 | |
| 131 | Automated Measuring Systems (AMS) | Formaldehyde concentration Range (0,034 – 50) mg/m3 |
High-performance liquid chromatography with diode array detection (HPLC-DAD) | CEN/TS 17638:2021 | |
| 132 | Waste gases | Gas volume flow rate for dynamic pressures > 5 Pa Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Differential pressure measurement method | PN-EN 16911-1:2013-07 CEN/TR 17078:2017 | |
| 133 | Waste gases | Gas volume flow rate for dynamic pressures > 5 Pa Velocity Range (0,4 – 15) m/s Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Stagnation pressure method; Thermoanemometric method | PN-Z-04030-7:1994 | |
| 134 | Waste gases | Sampling for determination of dust concentration Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-Z-04030-7:1994 | ||
| 135 | Waste gases | Dust concentration Range (0,001 – 5) g/m3 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Gravimetric method | PN-Z-04030-7:1994 | |
| 136 | Waste gases | Dust emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-Z-04030-7:1994 | ||
| 137 | Waste gases | Sampling for determination of dust concentration Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-EN 13284-1:2018-2 | ||
| 138 | Waste gases | Dust concentration Range (0,5 – 50) mg/m3 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Gravimetric method | PN-EN 13284-1:2018-2 | |
| 139 | Waste gases | Dust emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-EN 13284-1:2018-2 | ||
| 140 | Waste gases | Concentration of oxygen, nitrogen oxides, sulphur dioxide, carbon dioxide, carbon monoxide O2 (1 – 20,9) % NOx (1,4 – 2050) mg/m3 NO (0,7 – 1340) mg/m3 NOx (2,05 – 2050) mg/m3 NO (1,3 – 1340) mg/m3 SO2 (2,86 – 2000) mg/m3 CO2 (0,1 – 25) % CO (0,8 – 6250) mg/m3 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Paramagnetic method; Chemiluminescence method; Non-dispersive infrared spectrometry method (NDIR); Non-dispersive infrared spectrometry method (NDIR) | PN-ISO 10396:2001 | |
| 141 | Waste gases | Emission of NOx (NO and NO2 calculated as NO2), NO and NO2, SO2, CO2, CO (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-ISO 10396:2001 | ||
| 142 | Waste gases | Oxygen concentration Range (1 – 20,9) % Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Paramagnetic method | PN-EN 14789:2017-04 | |
| 143 | Waste gases | Carbon dioxide concentration Range (0,1 – 25) % Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Non-dispersive infrared spectrometry (NDIR) | ISO 12039:2019 | |
| 144 | Waste gases | Concentration of nitrogen oxides, nitrogen monoxide NOx (1,4 – 2050) mg/m3 NO (0,7 – 1340) mg/m3 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Chemiluminescence method | PN-EN 14792:2017-04 | |
| 145 | Waste gases | Emission of NOx (NO and NO2 calculated as NO2), NO, NO2 (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-EN 14792:2017-04 | ||
| 146 | Waste gases | Carbon monoxide concentration Range (0,8 – 6250) mg/m3 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Non-dispersive infrared spectrometry (NDIR) | PN-EN 15058:2017-04 | |
| 147 | Waste gases | Carbon monoxide emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-EN 15058:2017-04 | ||
| 148 | Waste gases | Water vapour concentration (H2O) Range (23 – 250) g/m3 Range (3 – 40) % Range (3,14 – 57,41) % Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Condensation-adsorption method; Temperature method | PN-EN 14790:2017-04 | |
| 149 | Waste gases | Concentration of organic substances in the form of gases and vapours expressed as total gaseous organic carbon Range (1,0 – 1000) mg/m3 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Continuous flame ionization detection method (FID) | PN-EN 12619:2013-05 | |
| 150 | Waste gases | Emission of organic substances in gaseous and vapour form expressed as total gaseous organic carbon (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-EN 12619:2013-05 | ||
| 151 | Waste gases | Sampling for the determination of PCDD/PCDF mass concentration Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-EN 1948-1:2006 | ||
| 152 | Waste gases | PCDD/PCDF emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-EN 1948-1:2006 | ||
| 153 | Waste gases | Sampling for determination of metal concentrations: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-EN 14385:2025-05 | ||
| 154 | Waste gases | Emission of metals: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-EN 14385:2025-05 | ||
| 155 | Waste gases | Sampling for determination of total mercury concentration Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-EN 13211:2006 | ||
| 156 | Waste gases | Total mercury emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-EN 13211:2006 | ||
| 157 | Waste gases | Sampling for determination of SO2 concentration Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-EN 14791:2017-04 | ||
| 158 | Waste gases | SO2 emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-EN 14791:2017-04 | ||
| 159 | Waste gases | Sampling for determination of hydrogen chloride concentration Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-EN 1911:2011 | ||
| 160 | Waste gases | Emission of hydrogen chloride (HCl) (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-EN 1911:2011 | ||
| 161 | Waste gases | Sampling for the determination of the concentration of hydrogen fluoride, fluorine, fluorides (HF, F, F−) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
ISO 15713:2006 CEN/TS 17340:2020 | ||
| 162 | Waste gases | Emission of hydrogen fluoride, fluorine, fluorides (HF, F, F−) (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
ISO 15713:2006 CEN/TS 17340:2020 | ||
| 163 | Waste gases | Sampling for the determination of organic compound concentration Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-Z-04008-4:1999 | ||
| 164 | Waste gases | Emission of organic compounds (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-Z-04008-4:1999 | ||
| 165 | Waste gases | Sampling for determination of the concentration of individual gaseous organic compounds Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-EN 13649:2005 CEN/TS 13649:2014 | ||
| 166 | Waste gases | Emission of individual gaseous organic compounds / sum of aromatic hydrocarbons / sum of aliphatic hydrocarbons (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-EN 13649:2005 CEN/TS 13649:2014 | ||
| 167 | Waste gases, General environment E - waste gas samples | Concentration / content of individual gaseous organic compounds Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
Flexible scope of accreditation E
E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body. |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN 13649:2005 CEN/TS 13649 | |
| 168 | Waste gases, General environment E - waste gas samples | Concentration / content of organic and inorganic compounds Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
Flexible scope of accreditation E
E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body. |
Ion chromatography with conductometric detection (IC-CD) | Standards, test procedures | |
| 169 | Waste gases, General environment E - waste gas samples | Concentration / content of inorganic compounds Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
Flexible scope of accreditation E
E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body. |
Thoron method | Standards | |
| 170 | Waste gases, General environment E - waste gas samples | Concentration / content of hydrogen chloride (HCl) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
Flexible scope of accreditation E
E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body. |
Spectrophotometric method | PN-EN 1911 | |
| 171 | Waste gases | Nitrous oxide concentration Range (1,6 – 150) mg/m3 |
Non-dispersive infrared spectrometry (NDIR) | PN-EN ISO 21258:2010 | |
| 172 | Waste gases | N2O emission (calculated) | PN-EN ISO 21258:2010 | ||
| 173 | Waste gases | Sampling for determination of dust concentration, PM 2,5 and PM 10 | PN-EN ISO 23210:2010 | ||
| 174 | Waste gases | PM 2,5 and PM 10 dust concentration Range (1 – 40) mg/m3 |
Gravimetric method (impaction) | PN-EN ISO 23210:2010 | |
| 175 | Waste gases | PM 2,5 and PM 10 dust emission (calculated) | PN-EN ISO 23210:2010 | ||
| 176 | Waste gases | Sampling for the determination of the mass concentration of dioxin-like PCBs, brominated flame retardants (BFR), polybrominated dibenzo-p-dioxins/furans (PBDD/F) | PN-EN 1948-1:2006 | PN-EN 1948-4+A1:2014-03 | ||
| 177 | Waste gases | Emission of PCB, BFR, PBDD/F (calculated) | PN-EN 1948-1:2006 | PN-EN 1948-4+A1:2014-03 | ||
| 178 | Waste gases | Sampling for the determination of isocyanate concentration | US EPA conditional test method (CTM) 036:2005 | ||
| 179 | Waste gases | Isocyanate emission (calculated) | US EPA conditional test method (CTM) 036:2005 | ||
| 180 | Waste gases | Sampling for determination of formaldehyde concentration | CEN/TS 17638:2021 | ||
| 181 | Waste gases | Formaldehyde emission (calculated) | CEN/TS 17638:2021 | ||
| 182 | Waste gases | Sampling for determination of the mass concentration of polycyclic aromatic hydrocarbons (PAH) | Filtration-condensation-adsorption method | ISO 11338-1:2003 | |
| 183 | Waste gases | PAH emission (calculated) | ISO 11338-1:2003 | ||
| 184 | Waste gases | Sampling for the determination of the concentration of sulphuric acid, including sulphuric acid mist and sulphur trioxide | US EPA method 8 issue of 14.01.2019 | ||
| 185 | Waste gases | Emission of sulphuric acid, including sulphuric acid mist and sulphur trioxide (calculated) | US EPA method 8 issue of 14.01.2019 | ||
| 186 | Waste gases | Sampling for determination of hydrogen sulphide concentration | US EPA method 11 issue of 03.08.2017 | ||
| 187 | Waste gases | Hydrogen sulphide emission (calculated) | US EPA method 11 issue of 03.08.2017 | ||
| 188 | Waste gases | Sampling for the determination of the concentration of hydrogen chloride, hydrogen bromide, hydrogen fluoride, chlorine, bromine. | US EPA method 26 issue of 14.01.2019 US EPA method 26A issue of 14.01.2019 | ||
| 189 | Waste gases | Emission of hydrogen chloride, hydrogen bromide, hydrogen fluoride, chlorine, bromine. (calculated) | US EPA method 26 issue of 14.01.2019 US EPA method 26A issue of 14.01.2019 | ||
| 190 | Waste gases | Sampling for determination of ammonia concentration | PN-EN ISO 21877:2020-03 | ||
| 191 | Waste gases | Ammonia emission (calculated) | PN-EN ISO 21877:2020-03 | ||
| 192 | Waste gases | Sampling for the determination of selenium concentration | ISO 17211:2015 | ||
| 193 | Waste gases | Emission of selenium (calculated) | ISO 17211:2015 | ||
| 194 | Waste gases | Sampling for the determination of organic compound concentration Tedlar |
Aspiration method using bags | Test procedure PB-94 issue 3 of 17.09.2021 | |
| 195 | Waste gases | Emission of organic compounds (calculated) | Test procedure PB-94 issue 3 of 17.09.2021 | ||
| 196 | Waste gases | Sampling for determination of the concentration of individual gaseous organic compounds | EPA – Method 18:2019 | ||
| 197 | Waste gases | Emission of individual gaseous organic compounds (calculated) | EPA – Method 18:2019 | ||
| 198 | Waste gases | Sampling for the determination of methane concentration | PN-EN ISO 25139:2011 | ||
| 199 | Waste gases | Methane emission (calculated) | PN-EN ISO 25139:2011 | ||
| 200 | Waste gases | Sampling for the determination of the concentration of metals: Sn, Fe, Zn, Mg, Al, Cr (III), Cr(VI), Ca, Cd, Mn, Cu, Pb, Cr, Ni, B, Be, Ba, Bi, Mo, Tl, As, Sb, Co, Ti, Ag, V, benzo(a)pyrene | Test procedure PB-11 issue 1 of 15.06.2023 | ||
| 201 | Waste gases | Emission of metals: Sn, Fe, Zn, Mg, Al, Cr(III), Cr(VI), Ca , Cd, Mn, Cu, Pb, Cr, Ni, B, Be, Ba, Bi, Mo, Tl, As, Sb, Co, Ti, Ag, V, benzo(a)pyrene (calculated) | Test procedure PB-11 issue 1 of 15.06.2023 | ||
| 202 | Waste gases | Sampling for the determination of the concentration of sulphuric acid and SO3, phenol, ozone, hydrogen sulphide, chlorine, nitrogen oxide, nitrogen dioxide, formaldehyde., Samples collected on filters and/or in absorption solutions | Test procedure PB-EM-01 issue 1 of 02.08.2026 | ||
| 203 | Waste gases | Emission of sulphuric acid and SO3, phenol, ozone, hydrogen sulphide, chlorine, nitrogen oxide, nitrogen dioxide, formaldehyde (calculated) | Test procedure PB-EM-01 issue 1 of 02.08.2026 | ||
| 204 | Waste gases, General environment E – waste gas samples collected on filters and sorbent tubes, condensate samples and absorbing solution samples | Concentration / content of organic compounds Regulated area: Flexible scope of accreditation E
E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body. |
High-performance liquid chromatography with fluorescence detection (HPLC-FLD); High-performance liquid chromatography with diode array detection (HPLC-DAD) | Standards | |
| 205 | Waste gases, General environment E – waste gas samples collected on filters and sorbent tubes, condensate samples and absorbing solution samples | Concentration / content of polycyclic aromatic hydrocarbons (PAH) Regulated area: Flexible scope of accreditation E
E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body. |
High-performance liquid chromatography with fluorescence detection (HPLC-FLD); High-performance liquid chromatography with diode array detection (HPLC-DAD) | Standards | |
| 206 | Waste gases, General environment E - waste gas samples collected on filters and sorbent tubes, condensate samples and absorbing solution samples | Concentration / content of isocyanates Regulated area: Flexible scope of accreditation E
E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body. |
High-performance liquid chromatography with fluorescence detection (HPLC-FLD) | Standards, test procedures | |
| 207 | Waste gases, General environment E – waste gas samples collected on filters and sorbent tubes, condensate samples and absorbing solution samples | Concentration / content of organic and inorganic compounds Regulated area: Flexible scope of accreditation E
E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body. |
Ion chromatography with conductometric detection (IC-CD) | Standards, test procedures | |
| 208 | Waste gases, General environment E – waste gas samples collected on filters and sorbent tubes, condensate samples and absorbing solution samples | Concentration / content of amines Regulated area: Flexible scope of accreditation E
E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body. |
Ion chromatography with conductometric detection (IC-CD) | Standards, test procedures | |
| 209 | Waste gases, General environment E – waste gas samples collected on filters and sorbent tubes, condensate samples and absorbing solution samples | Concentration / content of inorganic compounds Regulated area: Flexible scope of accreditation E
E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body. |
Titrimetric / thoron method | Standards, test procedures | |
| 210 | Waste gases, General environment E - waste gas samples | Concentration / content of metals Regulated area: Flexible scope of accreditation E
E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body. |
Flame atomic absorption spectrometry (FAAS) | Test procedures | |
| 211 | Waste gases, General environment E - waste gas samples | Concentration / content of individual gaseous organic compounds Regulated area: Flexible scope of accreditation E
E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body. |
Gas chromatography with flame ionization detection (GC-FID) | Standards | |
| 212 | Waste gases, General environment E - waste gas samples | Ammonia concentration / content Regulated area: Flexible scope of accreditation E
E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body. |
Spectrophotometric method | PN-EN ISO 21877 | |
| 213 | Waste gases, General environment E - waste gas samples | Concentration / content of chromium (VI) Regulated area: Flexible scope of accreditation E
E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body. |
Spectrophotometric method | Test procedure PB-95 | |
| 214 | Waste gases, General environment E - waste gas samples | Concentration / content of ozone Regulated area: Flexible scope of accreditation E
E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body. |
Spectrophotometric method | Test procedure PB-82 | |
| 215 | Waste gases, General environment E - waste gas samples | Concentration/ content of formaldehyde Regulated area: Flexible scope of accreditation E
E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body. |
Spectrophotometric method | Test procedure PB-54 | |
| 216 | Waste gases, General environment E - waste gas samples | Hydrogen sulphide concentration / content Regulated area: Flexible scope of accreditation E
E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body. |
Spectrophotometric method | Test procedure PB-96 | |
| 217 | Waste gases, General environment E - waste gas samples | Chlorine concentration / content Regulated area: Flexible scope of accreditation E
E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body. |
Spectrophotometric method | Test procedure PB-57 | |
| 218 | Waste gases, General environment E - waste gas samples | Phenol concentration / content Regulated area: Flexible scope of accreditation E
E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body. |
Spectrophotometric method | Test procedure PB-53 | |
| 219 | Waste gases, General environment E - waste gas samples | Concentration / content of nitrogen oxide and nitrogen dioxide Regulated area: Flexible scope of accreditation E
E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body. |
Spectrophotometric method | PN-Z-04009-11 | |
| 220 | Waste gases, General environment E - waste gas samples | Concentration / content of sulphur dioxide Regulated area: Flexible scope of accreditation E
E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body. |
Spectrophotometric method | PN-Z-04015-12 | |
| 221 | Wastewater E, Meltwater, Rainwater | Sampling for chemical and physical testing Temperature Range (0,0 – 50,0) °C Regulated area: Flexible scope of accreditation E
E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body. |
Manual method | PN-ISO 5667-10 | PN-77/C-04584 | |
| 222 | Wastewater E | pH Range 4,0 – 10,0 Regulated area: Flexible scope of accreditation E
E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body. |
Potentiometric method | PN-EN ISO 10523 | |
| 223 | Wastewater E | Metal concentrations Regulated area: Flexible scope of accreditation E
E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body. |
Flame atomic absorption spectrometry (FAAS) | PN-ISO 8288 Method A | |
Reference standards (106)
CEN/TS 17638:2021
EPA – Method 18:2019
ISO 11338-1:2003
ISO 12039:2019
ISO 15713:2006 CEN/TS 17340:2020
ISO 17211:2015
Working instruction No. IR-C1 issue 4 of 21.04.2024
NIOSH 7400, Issue 3
Standards
Standards, test procedures
PB-01-1 issue 1 of 05.04.2023
PB-01-2 issue 1 of 24.02.2026
PB-46 issue 3 of 05.04.2023
PB-65 issue 3 of 19.06.2023
PB-92 issue 2 of 19.06.2023
PN-70/Z-04044
PN-71/Z-04041
PN-75/Z-04037/03
PN-75/Z-04093/02
PN-76/Z-04045/02
PN-77/C-04584
PN-87/Z-04126/03
PN-93/Z-04225/03
PN-EN 12619:2013-05
PN-EN 13211:2006
PN-EN 13284-1:2018-2
PN-EN 13649:2005 CEN/TS 13649
PN-EN 13649:2005 CEN/TS 13649:2014
PN-EN 14181:2015
PN-EN 14253+A1:2011
PN-EN 14255-1:2010
PN-EN 14255-2:2010
PN-EN 14385:2025-05
PN-EN 14789:2017-04
PN-EN 14790:2017-04
PN-EN 14791:2017-04
PN-EN 14792:2017-04
PN-EN 15058:2017-04
PN-EN 16911-1:2013-07 CEN/TR 17078:2017
PN-EN 1911
PN-EN 1911:2011
PN-EN 1948-1:2006
PN-EN 1948-4+A1:2014-03
PN-EN ISO 10523
PN-EN ISO 11079:2008
PN-EN ISO 21258:2010
PN-EN ISO 21877
PN-EN ISO 21877:2020-03
PN-EN ISO 23210:2010
PN-EN ISO 25139:2011
PN-EN ISO 3744:2011 excluding cl. 8.3
PN-EN ISO 3746:2011+Ap1:2017-09 excluding cl. 8.4
PN-EN ISO 5349-1:2004
PN-EN ISO 5349-2:2004
PN-EN ISO 5349-2:2004/A1:2015-11
PN-EN ISO 7243:2018-01
PN-EN ISO 7243:2018-01/Ap2:2020-04
PN-EN ISO 7730:2006
PN-EN ISO 7730:2006/Ap2:2016-04
PN-EN ISO 9612:2025-11
PN-ISO 10396:2001
PN-ISO 5667-10
PN-ISO 8288 Method A
PN-N-01307:1994
PN-SO 9613-2:2002
PN-T-05687:2002 cl. 2.5.5
PN-T-06580-3:2002 Method adapted to the regulated area
PN-Z-01339:2020-12
PN-Z-04007-2
PN-Z-04008-4:1999
PN-Z-04008-7:2002 + Az1:2004
PN-Z-04009-11
PN-Z-04015-12
PN-Z-04015-13
PN-Z-04030-7:1994
PN-Z-04073-1
PN-Z-04108-5:2006
PN-Z-04507:2022-05
PN-Z-04507:2022-05/Ap1:2022-08
PN-Z-04508:2022-05
PN-Z-04508:2022-05/Ap1:2022-08
PN-Z-04548:2023-03
Principles and Methods of Assessing the Working Environment
Principles and Methods of Assessing the Working Environment 2012, issue 4 (74), pp. 117-130
Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 151–180
Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 91–150
Principles and Methods of Assessing the Working Environment 2017, No. 2 (92), pp. 89–131
Test procedure PB-11 issue 1 of 15.06.2023
Test procedure PB-53
Test procedure PB-54
Test procedure PB-57
Test procedure PB-82
Test procedure PB-94 issue 3 of 17.09.2021
Test procedure PB-95
Test procedure PB-96
Test procedure PB-EM-01 issue 1 of 02.08.2026
Test procedures
Clause 3 of the Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630)
Clause 3 of the Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022, item 2630)
US EPA conditional test method (CTM) 036:2005
US EPA method 11 issue of 03.08.2017
US EPA method 26 issue of 14.01.2019 US EPA method 26A issue of 14.01.2019
US EPA method 8 issue of 14.01.2019
Page version: A
Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630)
Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023, item 1706)