🇵🇱 GRUPA EKOPROJEKT Sp. z o. o. PL

PCA AB 409 • Bielsko-Biała, Poland • 223 methods

EnvironmentMaterials & polymers

GRUPA EKOPROJEKT Sp. z o. o. is a laboratory accredited by PCA under number AB 409 (Bielsko-Biała, Poland). Its accreditation scope covers 223 test methods in the following areas: Environment, Materials & polymers. Test objects include: Waste gases, Automated Measuring Systems (AMS), Working environment E - air - air samples collected into an absorbi…, Waste gases, General environment E - waste gas samples. Most frequently used techniques: Direct measurement method, Spectrophotometric method, Ion chromatography with conductometric detection (IC-CD).

At a glance

  • Accreditation number: PCA AB 409
  • Methods in scope: 223
  • Types of test objects: 43
  • Techniques used: 38
  • City: Bielsko-Biała, Poland
Accreditation number
AB 409
Accreditation body
PCA
Address
LABORATORIUM BADAŃ ŚRODOWISKA, ul. Kazimierza Wielkiego 15, 43-300 Bielsko-Biała
City
Bielsko-Biała, Poland

What this laboratory tests (43)

Analytical techniques used (38)

Laboratory locations

Certificate information

Issue date
03.09.2026
Issue no.
35

Accreditation scope — test methods (223)

No. Test object Methodology / Parameters Technique Reference document
Environmental Testing Laboratory
1 Workplace environment – noise A-weighted equivalent sound level, A-weighted maximum sound level, C-weighted peak sound level,
Range (35 – 135) dB
Direct measurement method PN-N-01307:1994 | PN-EN ISO 9612:2025-11
2 Workplace environment – noise Noise exposure level referred to:
an 8-hour daily working time the average weekly working time (calculated)
PN-N-01307:1994 | PN-EN ISO 9612:2025-11
3 Workplace environment – ultrasonic noise Equivalent sound pressure level in one-third octave bands with centre frequencies from 10 kHz to 40 kHz Maximum sound pressure level in one-third octave bands with centre frequencies from 10 kHz to 40 kHz
Range (54 – 139) dB
Direct measurement method PN-Z-01339:2020-12
4 Workplace environment – ultrasonic noise Equivalent sound pressure level in one-third octave bands with centre frequencies from 10 kHz to 40 kHz referred to: – the 8-hour daily working time – the average weekly working time (calculated) PN-Z-01339:2020-12
5 General environment - noise from installations and equipment and industrial plants A-weighted equivalent sound pressure level
Range (25 – 135) dB
Direct measurement method Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023, item 1706) | PN-SO 9613-2:2002
6 General environment - noise from installations and equipment and industrial plants A-weighted equivalent sound level for the time T expressed by the indicator LAeqD and LAeqN (calculated) Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023, item 1706) | PN-SO 9613-2:2002
7 General environment - noise from installations and equipment and industrial plants A-weighted equivalent sound level for time T expressed by the indicator LAeqD and LAeqN Calculation method Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023, item 1706) | PN-SO 9613-2:2002
8 Machinery and equipment – noise Sound pressure level
weighted with the characteristic frequency weighting A Range (25 – 135) dB
Direct measurement method PN-EN ISO 3744:2011 excluding cl. 8.3 | PN-EN ISO 3746:2011+Ap1:2017-09 excluding cl. 8.4
9 Machinery and equipment – noise Sound power level (calculated) PN-EN ISO 3744:2011 excluding cl. 8.3 | PN-EN ISO 3746:2011+Ap1:2017-09 excluding cl. 8.4
10 Workplace environment - hand-arm vibration Frequency-weighted r.m.s. vibration acceleration
Range (0,05 – 100) m/s2
Direct measurement method PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11
11 Workplace environment - hand-arm vibration Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the vector sum of the r.m.s. frequency-corrected vibration accelerations determined for three directional components (ahwx, ahwy, ahwz), Exposure lasting 30 minutes or less, expressed as the vector sum of the r.m.s. frequency-weighted vibration accelerations determined for three directional components (ahwx, ahwy, ahwz) (calculated) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11
12 Workplace environment − whole-body vibration Frequency-weighted r.m.s. vibration acceleration
Range (0,02 – 50) m/s2
Direct measurement method PN-EN 14253+A1:2011
13 Workplace environment − whole-body vibration Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the r.m.s. frequency-corrected vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz), Exposure lasting 30 minutes or less, expressed as the r.m.s. frequency-weighted vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz) (calculated) PN-EN 14253+A1:2011
14 Workplace environment − moderate microclimate Air temperature
Range (10 – 30) °C Black globe temperature Range (10 – 40) °C Air humidity Range (30 – 90) % Air velocity Range (0,15 – 4,8) m/s
Direct measurement method PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04
15 Workplace environment − moderate microclimate PMV index, PPD index (calculated) PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04
16 Workplace environment − moderate microclimate Page version: A
17 Workplace environment − cold microclimate Air temperature
Range (-20 – 10) °C Black globe temperature Range (- 20 – 10) °C Air humidity Range (30 – 90) % Air velocity Range (0,15 – 4,8) m/s
Direct measurement method PN-EN ISO 11079:2008
18 Workplace environment − cold microclimate IREQmin index, IREQneutral index, twc index (calculated) PN-EN ISO 11079:2008
19 Workplace environment − hot microclimate Air temperature
Range (15 – 50) °C Natural wet bulb temperature Range (15 – 40) °C Black globe temperature Range (15 – 50) °C
Direct measurement method PN-EN ISO 7243:2018-01 | PN-EN ISO 7243:2018-01/Ap2:2020-04
20 Workplace environment − hot microclimate WBGT index, WBGTeff index (calculated) PN-EN ISO 7243:2018-01 | PN-EN ISO 7243:2018-01/Ap2:2020-04
21 Workplace environment Illuminance,
Range (0,5 – 10000) lx
PB-65 issue 3 of 19.06.2023
22 indoors Direct measurement method PB-65 issue 3 of 19.06.2023
23 indoors Illuminance uniformity (calculated) PB-65 issue 3 of 19.06.2023
24 Workplace environment - outdoor electric lighting, General environment - outdoor electric lighting Illuminance,
Range (0,5 – 10000) lx
Direct measurement method PB-92 issue 2 of 19.06.2023
25 Workplace environment - outdoor electric lighting, General environment - outdoor electric lighting Illuminance uniformity (calculated) PB-92 issue 2 of 19.06.2023
26 Workplace environment – energy expenditure Air temperature
Range (0 – 60) °C Air flow Range (10 – 60) dm 3/min
Direct measurement method PB-46 issue 3 of 05.04.2023
27 Workplace environment – energy expenditure Energy expenditure (calculated) PB-46 issue 3 of 05.04.2023
28 Workplace environment - non-laser optical radiation Effective irradiance, UVA, UVB and UVC in the spectral range (180 – 400) nm, Measurement range (8,00*10-4 – 10), W/m2 Direct measurement method (method A) PN-EN 14255-1:2010
29 Workplace environment - non-laser optical radiation Effective irradiation UVA, UVB and UVC in the spectral range (180 – 400) nm (calculated) PN-EN 14255-1:2010
30 Workplace environment - non-laser optical radiation Irradiance of UVA in the spectral range (315 – 400) nm, Measurement range (2,50*10-4 – 8,75*102) W/m2 Direct measurement method (method M) PN-EN 14255-1:2010
31 Workplace environment - non-laser optical radiation Radiant exposure of UVA in the spectral range (315 – 400) nm (calculated) PN-EN 14255-1:2010
32 Workplace environment - non-laser optical radiation Effective irradiance, VIS in the spectral range (315 – 700) nm, Measurement range (2,00*10-4 – 3,00*103) W/m2 Direct measurement method (method O) PN-EN 14255-2:2010
33 Workplace environment - non-laser optical radiation Effective VIS luminance in the spectral range (400 – 700) nm (calculated) PN-T-05687:2002 cl. 2.5.5
34 Workplace environment - non-laser optical radiation Irradiance of IRA and IRB in the spectral range (770 – 3000) nm, Measurement range (9,00*10-1 – 4,00*103) W/m2 Direct measurement method (method R) PN-EN 14255-2:2010
35 Working environment - electromagnetic field from industrial installations and equipment: - arc welding equipment - resistance welders - industrial magnetisers and demagnetisers - electrolytic installations - NMR spectrometers - dielectric heating equipment - induction heating equipment - industrial microwave furnaces, heaters and dryers - equipment for the production and processing of plastics - soldering equipment - electrical discharge machines - resistance and arc furnaces - inverters - household electrical equipment - electric vehicles and traction systems Magnetic flux density (0 Hz)
Range (0,21 – 1000) mT in the frequency range from 5 Hz up to 500 kHz Range (0,15 –18750) μT
Direct measurement method PN-T-06580-3:2002 Method adapted to the regulated area | Working instruction No. IR-C1 issue 4 of 21.04.2024
36 Working environment - electromagnetic field from industrial installations and equipment: - arc welding equipment - resistance welders - industrial magnetisers and demagnetisers - electrolytic installations - NMR spectrometers - dielectric heating equipment - induction heating equipment - industrial microwave furnaces, heaters and dryers - equipment for the production and processing of plastics - soldering equipment - electrical discharge machines - resistance and arc furnaces - inverters - household electrical equipment - electric vehicles and traction systems Electric field strength:
in the frequency range from 5 Hz up to 90 GHz Range (1– 50 000) V/m
Direct measurement method PN-T-06580-3:2002 Method adapted to the regulated area | Working instruction No. IR-C1 issue 4 of 21.04.2024
37 Working environment - electromagnetic field from industrial installations and equipment: - arc welding equipment - resistance welders - industrial magnetisers and demagnetisers - electrolytic installations - NMR spectrometers - dielectric heating equipment - induction heating equipment - industrial microwave furnaces, heaters and dryers - equipment for the production and processing of plastics - soldering equipment - electrical discharge machines - resistance and arc furnaces - inverters - household electrical equipment - electric vehicles and traction systems Magnetic field strength:
in the frequency range From 100 kHz up to 1 GHz Range (0,010 – 16) A/m
Direct measurement method PN-T-06580-3:2002 Method adapted to the regulated area | Working instruction No. IR-C1 issue 4 of 21.04.2024
38 Working environment - electromagnetic field from industrial installations and equipment: - arc welding equipment - resistance welders - industrial magnetisers and demagnetisers - electrolytic installations - NMR spectrometers - dielectric heating equipment - induction heating equipment - industrial microwave furnaces, heaters and dryers - equipment for the production and processing of plastics - soldering equipment - electrical discharge machines - resistance and arc furnaces - inverters - household electrical equipment - electric vehicles and traction systems Magnetic field strength:
in the frequency range from 800 MHz up to 90 GHz (calculated)
PN-T-06580-3:2002 Method adapted to the regulated area | Working instruction No. IR-C1 issue 4 of 21.04.2024
39 Working environment - electromagnetic field from radiocommunication and anti-theft systems: - hand-held radiotelephones, terminals and short-range wireless devices, body-worn and vehicle radio stations (radiotelephones) - anti-theft and electronic article surveillance systems - radar and radiolocation systems Magnetic flux density (0 Hz)
Range (0,21 – 1000) mT in the frequency range from 5 Hz up to 500 kHz Range (0,15 –18750) μT
Direct measurement method PN-T-06580-3:2002 Method adapted to the regulated area | Working instruction No. IR-C1 issue 4 of 21.04.2024
40 Working environment - electromagnetic field from radiocommunication and anti-theft systems: - hand-held radiotelephones, terminals and short-range wireless devices, body-worn and vehicle radio stations (radiotelephones) - anti-theft and electronic article surveillance systems - radar and radiolocation systems Electric field strength:
in the frequency range from 5 Hz up to 90 GHz Range (1– 50 000) V/m
Direct measurement method PN-T-06580-3:2002 Method adapted to the regulated area | Working instruction No. IR-C1 issue 4 of 21.04.2024
41 Working environment - electromagnetic field from radiocommunication and anti-theft systems: - hand-held radiotelephones, terminals and short-range wireless devices, body-worn and vehicle radio stations (radiotelephones) - anti-theft and electronic article surveillance systems - radar and radiolocation systems Magnetic field strength:
in the frequency range From 100 kHz up to 1 GHz Range (0,010 – 16) A/m
Direct measurement method PN-T-06580-3:2002 Method adapted to the regulated area | Working instruction No. IR-C1 issue 4 of 21.04.2024
42 Working environment - electromagnetic field from radiocommunication and anti-theft systems: - hand-held radiotelephones, terminals and short-range wireless devices, body-worn and vehicle radio stations (radiotelephones) - anti-theft and electronic article surveillance systems - radar and radiolocation systems Magnetic field strength:
in the frequency range from 800 MHz up to 90 GHz (calculated)
PN-T-06580-3:2002 Method adapted to the regulated area | Working instruction No. IR-C1 issue 4 of 21.04.2024
43 Workplace environment - electromagnetic field originating from equipment used in medical technology: - surgical diathermy - physiotherapeutic diathermy - magnetic resonance scanners Magnetic flux density (0 Hz)
Range (0,21 – 1000) mT in the frequency range from 5 Hz up to 500 kHz Range (0,15 – 18750) μT
Direct measurement method PN-T-06580-3:2002 Method adapted to the regulated area | Working instruction No. IR-C1 issue 4 of 21.04.2024
44 Workplace environment - electromagnetic field originating from equipment used in medical technology: - surgical diathermy - physiotherapeutic diathermy - magnetic resonance scanners Electric field strength:
in the frequency range from 5 Hz up to 90 GHz Range (1 – 50 000) V/m
Direct measurement method PN-T-06580-3:2002 Method adapted to the regulated area | Working instruction No. IR-C1 issue 4 of 21.04.2024
45 Workplace environment - electromagnetic field originating from equipment used in medical technology: - surgical diathermy - physiotherapeutic diathermy - magnetic resonance scanners Magnetic field strength:
in the frequency range From 100 kHz up to 1 GHz Range (0,010 – 16) A/m
Direct measurement method PN-T-06580-3:2002 Method adapted to the regulated area | Working instruction No. IR-C1 issue 4 of 21.04.2024
46 Workplace environment - electromagnetic field originating from equipment used in medical technology: - surgical diathermy - physiotherapeutic diathermy - magnetic resonance scanners Magnetic field strength:
in the frequency range from 800 MHz up to 90 GHz (calculated)
PN-T-06580-3:2002 Method adapted to the regulated area | Working instruction No. IR-C1 issue 4 of 21.04.2024
47 Workplace environment - electromagnetic field in the workspace during the use of power systems and AC electrical supply installations in the power industry Electric field strength:
in the frequency range from 45 Hz up to 55 Hz Range (0,10 – 50) kV/m
Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (consolidated text: Journal of Laws of 2018, item 331).
Direct measurement method Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 91–150
48 Workplace environment - electromagnetic field in the workspace during the use of power systems and AC electrical supply installations in the power industry Magnetic flux density:
in the frequency range from 45 Hz up to 55 Hz Range (1,0 –18750) μT
Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (consolidated text: Journal of Laws of 2018, item 331).
Direct measurement method Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 91–150
49 Workplace environment - electromagnetic field in the workspace during the use of power systems and AC electrical supply installations in the power industry Magnetic field strength in the frequency range from 45 Hz to 55 Hz (calculated)
Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (consolidated text: Journal of Laws of 2018, item 331).
Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 91–150
50 Workplace environment - electromagnetic field in the workspace during the use of magnetotherapy devices Magnetic flux density:
in the frequency range from 20 Hz up to 50 Hz Range (15 – 1600) μT
Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (consolidated text: Journal of Laws of 2018, item 331).
Direct measurement method (simplified) Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 151–180
51 Workplace environment - electromagnetic field in the workspace during the use of magnetotherapy devices Magnetic field strength in the frequency range from 20 Hz to 50 Hz (calculated)
Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (consolidated text: Journal of Laws of 2018, item 331).
Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 151–180
52 Workplace environment – electromagnetic field in the workspace during the use of transmitting devices of radiocommunication systems (mobile telephony base stations, broadcasting and radiocommunication systems – radio, television) Electric field strength:
in the frequency range from 200 kHz up to 90 GHz Range (1 – 1000) V/m
Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (consolidated text: Journal of Laws of 2018, item 331).
Direct measurement method Principles and Methods of Assessing the Working Environment 2017, No. 2 (92), pp. 89–131
53 Workplace environment – electromagnetic field in the workspace during the use of transmitting devices of radiocommunication systems (mobile telephony base stations, broadcasting and radiocommunication systems – radio, television) Magnetic field strength:
in the frequency range from 200 kHz up to 1 GHz Range (0,010 – 16) A/m
Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (consolidated text: Journal of Laws of 2018, item 331).
Direct measurement method Principles and Methods of Assessing the Working Environment 2017, No. 2 (92), pp. 89–131
54 Workplace environment – electromagnetic field in the workspace during the use of transmitting devices of radiocommunication systems (mobile telephony base stations, broadcasting and radiocommunication systems – radio, television) Magnetic field strength:
in the frequency range from 0,8 GHz up to 90 GHz (calculated)
Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (consolidated text: Journal of Laws of 2018, item 331).
Principles and Methods of Assessing the Working Environment 2017, No. 2 (92), pp. 89–131
55 Environment – electromagnetic field in the vicinity of electric power substations and power lines Electric field strength in the frequency range 50 Hz
Range (0,10 – 50) kV/m
Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
Direct measurement method Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630)
56 Environment – electromagnetic field in the vicinity of electric power substations and power lines Magnetic flux density in the frequency range 50 Hz
Range (1,0 – 18750) μT
Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
Direct measurement method Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630)
57 Environment – electromagnetic field in the vicinity of electric power substations and power lines Magnetic field strength in the frequency range 50 Hz (calculated)
Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630)
58 Environment – electromagnetic field in the vicinity of radiocommunication and radionavigation installations (broadband measurements) Electric field strength:
in the frequency range from 100 kHz up to 3 GHz Range (0,9 – 1300) V/m in the frequency range from 0,3 GHz up to 90 GHz Range (0,8 – 400) V/m
Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
Direct measurement method Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630)
59 Environment – electromagnetic field in the vicinity of radiocommunication and radionavigation installations (broadband measurements) Magnetic field strength:
in the frequency range from 300 kHz up to 30 MHz Range (0,011 – 16) A/m in the frequency range from 30 MHz up to 1 GHz Range (0,011 – 8,8) A/m
Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
Direct measurement method Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630)
60 Environment – electromagnetic field in the vicinity of radiocommunication and radionavigation installations (broadband measurements) Magnetic field strength:
in the frequency range from 10 MHz up to 90 GHz (calculated)
Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
Clause 3 of the Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630)
61 Environment – electromagnetic field in the vicinity of radiocommunication and radionavigation installations (broadband measurements) Magnetic flux density:
in the frequency range from 5 Hz up to 500 kHz Range 17 nT – 19 mT
Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
Direct measurement method Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630)
62 Environment – electromagnetic field in the vicinity of radiocommunication and radionavigation installations (broadband measurements) Magnetic field strength:
in the frequency range from 5 Hz up to 500 kHz (calculated)
Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630)
63 Environment – electromagnetic field in the vicinity of radar installations (broadband measurements) Electric field strength:
in the frequency range from 0,1 MHz up to 90 GHz Range (0,8 – 400) V/m
Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
Direct measurement method Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630)
64 Environment – electromagnetic field in the vicinity of radar installations (broadband measurements) Magnetic field strength:
in the frequency range from 10 MHz up to 90 GHz (calculated)
Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
Clause 3 of the Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022, item 2630)
65 Workplace environment – air Sampling for the assessment of occupational exposure to:
dust agents inhalable fraction respirable fraction organic substances, including inhalable fraction inorganic substances, including inhalable fraction respirable fraction thoracic fraction metals and their compounds, including inhalable fraction respirable fraction asbestos respirable fibres man-made mineral fibres, excluding refractory ceramic fibres inhalable fraction respirable fibres
Personal dosimetry method PN-Z-04008-7:2002 + Az1:2004
66 Workplace environment – air Exposure index (calculated) PN-Z-04008-7:2002 + Az1:2004
67 Workplace environment – air Concentration of harmful dust agents - inhalable fraction
Apatites and phosphorites Petroleum bitumen Portland cement Titanium dioxide Natural graphite Synthetic graphite Kaolin Amorphous and synthetic silica Wood dusts Flour dusts Dusts not classified according to toxicity Organic dusts of animal and plant origin, excluding wood and flour dusts Calcium sulfate (VI) (gypsum) Carbon black Talc Coal (hard, brown) Calcium magnesium carbonate (dolomite) Silicon carbide (non-fibrous) Man-made mineral fibres excluding refractory ceramic fibres Range (0,19 – 20) mg/m3
Gravimetric method PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08
68 Workplace environment – air Concentration of dust harmful to health - respirable fraction
Apatites and phosphorites Portland cement Natural graphite Amorphous and synthetic silica Organic dusts of animal and plant origin, excluding wood and flour dusts Talc Coal (hard, brown) Range (0,1 – 4,0) mg/m3
Gravimetric method PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08
69 Workplace environment – air Carbon monoxide concentration
Range (2,3 – 234) mg/m3 Range (1,98 – 201) ppm
Electrochemical method PB-01-1 issue 1 of 05.04.2023
70 Workplace environment – air Carbon dioxide concentration
Range (900 – 54000) mg/m3 Range (493 – 29570) ppm
Infrared spectrometry method (IR) PB-01-1 issue 1 of 05.04.2023
71 Workplace environment – air Nitrogen oxide concentration
Range (0,25 – 5,0) mg/m3 Range (0,2 – 4,0) ppm
Electrochemical method PB-01-1 issue 1 of 05.04.2023
72 Workplace environment – air Nitrogen dioxide concentration
Range (0,07 – 3,0) mg/m3 Range (0,0366 – 1,57) ppm
Electrochemical method PB-01-1 issue 1 of 05.04.2023
73 Work environment – air - air samples collected in a plastic bag Concentration / content of dinitrogen oxide
Range (9 – 180 mg/m3)
Non-dispersive infrared spectrometry (NDIR) PB-01-2 issue 1 of 24.02.2026
74 Workplace environment – air – air samples collected on filters Number concentration / content:
asbestos fibres refractory ceramic fibres refractory ceramic fibres in a mixture with other man-made mineral fibres respirable man-made mineral fibres, except refractory ceramic fibres respirable fibres of fibrous silicon carbide Range (0,001 – 2) fibres/cm3 Range (981 – 770000) fibres/sample
Phase-contrast optical microscopy method NIOSH 7400, Issue 3
75 Working environment E – air – air samples collected on filters and sorbent tubes, condensate samples and samples collected into absorbing solutions Concentration / content of organic compounds
Regulated area: Flexible scope of accreditation E E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body.
High-performance liquid chromatography with fluorescence detection (HPLC-FLD) Standards, test procedures
76 Working environment E – air – air samples collected on filters and sorbent tubes, condensate samples and samples collected into absorbing solutions Concentration / content of organic compounds
Regulated area: Flexible scope of accreditation E E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body.
High-performance liquid chromatography with diode array detection (HPLC-DAD) Standards, test procedures
77 Work environment E – air – air samples collected on filters and in sorbent tubes Concentration / content of polycyclic aromatic hydrocarbons:
Regulated area: Flexible scope of accreditation E E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body.
High-performance liquid chromatography with fluorescence detection (HPLC-FLD) Standards
78 Workplace environment E – air – air samples collected on filters Concentration / content of diisocyanates expressed as NCO group, Diisocyanates – expressed as group, NCO (sum of concentrations/contents of isocyanate functional groups of diisocyanate compounds)
Regulated area: Flexible scope of accreditation E E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body.
High-performance liquid chromatography with fluorescence detection (HPLC-FLD) Standards, test procedures
79 Working environment E - air - air samples collected on filters, on sorbent tubes, condensates and into an absorbing solution Concentration / content of organic and inorganic compounds
Regulated area: Flexible scope of accreditation E E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body.
Ion chromatography with conductometric detection (IC-CD) Standards, test procedures
80 Working environment E - air - air samples collected on filters, on sorbent tubes, condensates and into an absorbing solution Concentration / content of amines
Regulated area: Flexible scope of accreditation E E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body.
Ion chromatography with conductometric detection (IC-CD) Standards, test procedures
81 Work environment E - air - air samples collected on sorbent tubes - air samples collected in a plastic bag Concentration / content of organic substances
Regulated area: Flexible scope of accreditation E E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Standards
82 Workplace environment E - air - air samples collected on filters Concentration / content of metals and their compounds
Regulated area: Flexible scope of accreditation E E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body.
Flame atomic absorption spectrometry (FAAS) Standards, test procedures
83 Workplace environment E - air - air samples collected on filters Concentration / content of crystalline silica
respirable fraction
Regulated area: Flexible scope of accreditation E E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body.
Fourier transform infrared spectrometry (FT-IR) Principles and Methods of Assessing the Working Environment 2012, issue 4 (74), pp. 117-130
84 Workplace environment E - air - air samples collected on filters Concentration / content of highly refined mineral oils excluding metalworking fluids
inhalable fraction
Regulated area: Flexible scope of accreditation E E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body.
Fourier transform infrared absorption spectrometry method (FT-IR) PN-Z-04108-5:2006
85 Working environment E - air - air samples collected into an absorbing solution Ammonia concentration / content
Regulated area: Flexible scope of accreditation E E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body.
Spectrophotometric method PN-71/Z-04041
86 Working environment E - air - air samples collected into an absorbing solution Hydrogen chloride concentration / content
Regulated area: Flexible scope of accreditation E E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body.
Turbidimetric method PN-93/Z-04225/03
87 Working environment E - air - air samples collected into an absorbing solution Concentration / content of phenol (hydroxybenzene, carbolic acid)
Regulated area: Flexible scope of accreditation E E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body.
Spectrophotometric method PN-70/Z-04044
88 Working environment E - air - air samples collected into an absorbing solution Concentration / content of formaldehyde (formic aldehyde, methanal, formalin)
Regulated area: Flexible scope of accreditation E E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body.
Spectrophotometric method PN-76/Z-04045/02
89 Working environment E - air - air samples collected into an absorbing solution Concentration / content of nitrogen monoxide and nitrogen dioxide
Regulated area: Flexible scope of accreditation E E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body.
Spectrophotometric method PN-Z-04009-11
90 Working environment E - air - air samples collected into an absorbing solution Nitric acid concentration (calculated)
Regulated area: Flexible scope of accreditation E E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body.
PN-Z-04009-11
91 Working environment E - air - air samples collected into an absorbing solution Concentration / content of phosphoric (V) acid (orthophosphoric acid)
Regulated area: Flexible scope of accreditation E E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body.
Spectrophotometric method PN-Z-04073-1
92 Working environment E - air - air samples collected into an absorbing solution Concentration / content of tetraphosphorus decaoxide (phosphorus pentoxide, diphosphorus pentaoxide, phosphoric (V) acid anhydride, orthophosphoric (V) acid anhydride, phosphorus decaoxide)
Regulated area: Flexible scope of accreditation E E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body.
Spectrophotometric method PN-Z-04073-1
93 Working environment E - air - air samples collected into an absorbing solution Concentration / content of ozone
Regulated area: Flexible scope of accreditation E E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body.
Spectrophotometric method PN-Z-04007-2
94 Working environment E - air - air samples collected into an absorbing solution Chlorine concentration / content
Regulated area: Flexible scope of accreditation E E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body.
Spectrophotometric method PN-75/Z-04037/03
95 Working environment E - air - air samples collected into an absorbing solution Concentration / content of chlorine dioxide
Regulated area: Flexible scope of accreditation E E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body.
Spectrophotometric method PN-75/Z-04037/03
96 Working environment E - air - air samples collected into an absorbing solution Concentration / content of hydrogen peroxide (hydrogen dioxide)
Regulated area: Flexible scope of accreditation E E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body.
Spectrophotometric method Principles and Methods of Assessing the Working Environment
97 Working environment E - air - air samples collected into an absorbing solution Concentration / content of hydrogen peroxide (hydrogen dioxide)
Regulated area: Flexible scope of accreditation E E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body.
Spectrophotometric method PN-Z-04548:2023-03
98 Working environment E - air - air samples collected into an absorbing solution Concentration / content of fluorides expressed as F−
Regulated area: Flexible scope of accreditation E E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body.
Spectrophotometric method PN-75/Z-04093/02
99 Working environment E - air - air samples collected into an absorbing solution Concentration / content of hydrogen fluoride (hydrofluoric acid)
Regulated area: Flexible scope of accreditation E E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body.
Spectrophotometric method PN-75/Z-04093/02
100 Working environment E - air - air samples collected into an absorbing solution Concentration / content of sulphur dioxide
Regulated area: Flexible scope of accreditation E E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body.
Spectrophotometric method PN-Z-04015-12
101 Working environment E - air - air samples collected into an absorbing solution Hydrogen sulphide concentration / content
Regulated area: Flexible scope of accreditation E E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body.
Spectrophotometric method PN-Z-04015-13
102 Workplace environment E - air - air samples collected on filters Concentration / content of chromium (VI) compounds - expressed as Cr (VI)
Regulated area: Flexible scope of accreditation E E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body.
Spectrophotometric method PN-87/Z-04126/03
103 General environment E - ambient air samples collected on filters and sorbent tubes, condensate samples and samples collected into absorbing solutions, Indoor spaces E - air samples collected on filters and sorbent tubes, condensate samples and samples collected into absorbing solutions Content of organic compounds
Regulated area: Flexible scope of accreditation E E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body.
High-performance liquid chromatography with fluorescence detection (HPLC-FLD); High-performance liquid chromatography with diode array detection (HPLC-DAD) Standards, test procedures
104 General environment E - ambient air samples collected on filters and sorbent tubes, condensate samples and samples collected into absorbing solutions, Indoor spaces E - air samples collected on filters and sorbent tubes, condensate samples and samples collected into absorbing solutions Content of organic compounds
Regulated area: Flexible scope of accreditation E E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body.
High-performance liquid chromatography with diode array detection (HPLC-DAD) Standards, test procedures
105 General environment E - ambient air samples collected on filters and sorbent tubes, condensate samples and samples collected into absorbing solutions, Indoor spaces E - air samples collected on filters and sorbent tubes, condensate samples and samples collected into absorbing solutions Isocyanate content
Regulated area: Flexible scope of accreditation E E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body.
High-performance liquid chromatography with fluorescence detection (HPLC-FLD) Standards, test procedures
106 General environment E - ambient air samples collected on filters and sorbent tubes, Indoor spaces E - air samples collected on filters and sorbent tubes Content of polycyclic aromatic hydrocarbons
Regulated area: Flexible scope of accreditation E E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body.
High-performance liquid chromatography with fluorescence detection (HPLC-FLD); High-performance liquid chromatography with diode array detection (HPLC-DAD) Standards
107 General environment E - ambient air samples collected on filters and sorbent tubes, condensate samples and samples collected into absorbing solutions, Indoor spaces E - air samples collected on filters and sorbent tubes, condensate samples and samples collected into absorbing solutions Content of organic and inorganic compounds
Regulated area: Flexible scope of accreditation E E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body.
Ion chromatography with conductometric detection (IC-CD) Standards, test procedures
108 General environment E - ambient air samples collected on filters and sorbent tubes, condensate samples and samples collected into absorbing solutions, Indoor spaces E - air samples collected on filters and sorbent tubes, condensate samples and samples collected into absorbing solutions Amine content
Regulated area: Flexible scope of accreditation E E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body.
Ion chromatography with conductometric detection (IC-CD) Standards, test procedures
109 General environment E - ambient air samples collected on sorbent tubes - ambient air samples collected in a plastic bag, Indoor spaces E - air samples collected on sorbent tubes - air samples collected in a plastic bag Content of organic substances
Regulated area: Flexible scope of accreditation E E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Standards
110 Automated Measuring Systems (AMS) Annual surveillance test (AST) for: dust, NO, NOx, O2, CO2, CO, SO2, H2O, HCl, HF, Hg, concentration of organic substances in the form of gases and vapours expressed as total gaseous organic carbon
Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
PN-EN 14181:2015
111 Automated Measuring Systems (AMS) Calibration (QAL2) for: dust, NO, NOx, O2, CO2, CO, SO2, H2O, HCl, HF, Hg, concentration of organic substances in the form of gases and vapours expressed as total gaseous organic carbon
Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
PN-EN 14181:2015
112 Automated Measuring Systems (AMS) Water vapour concentration (H2O)
Range (23 – 250) g/m3 Range (3 – 40) % Range (3,14 – 57,41) %
Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Condensation-adsorption method; Temperature method PN-EN 14790:2017-04
113 Automated Measuring Systems (AMS) Dust concentration
Range (0,001 – 5) g/m3
Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Gravimetric method PN-Z-04030-7:1994
114 Automated Measuring Systems (AMS) Dust concentration
Range (0,5 – 50) mg/m3
Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Gravimetric method PN-EN 13284-1:2018-2
115 Automated Measuring Systems (AMS) Concentration of nitrogen oxides, nitrogen monoxide
NOx (1,4 – 2050) mg/m3 NO (0,7 – 1340) mg/m3
Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Chemiluminescence method CLD PN-EN 14792:2017-04
116 Automated Measuring Systems (AMS) Oxygen concentration
Range (1 – 20,9) %
Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Paramagnetic method PN-EN 14789:2017-04
117 Automated Measuring Systems (AMS) Carbon dioxide concentration
Range (0,1– 25) %
Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Non-dispersive infrared spectrometry (NDIR) ISO 12039:2019
118 Automated Measuring Systems (AMS) Carbon monoxide concentration
Range (0,8 – 6250) mg/m3
Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Non-dispersive infrared spectrometry (NDIR) PN-EN 15058:2017-04
119 Automated Measuring Systems (AMS) Concentration of organic substances in the form of gases and vapours expressed as total gaseous organic carbon
Range (1,0 – 1000) mg/m3
Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Continuous flame ionization detection method (FID) PN-EN 12619:2013-05
120 Automated Measuring Systems (AMS) Concentration of sulphur dioxide(SO2)
Range (0,17 – 2400) mg/m3
Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Ion chromatography with conductometric detection (IC-CD) PN-EN 14791:2017-04
121 Automated Measuring Systems (AMS) Sulphur dioxide concentration (SO2)
Range (1,00 – 2100) mg/m3
Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Thoron method PN-EN 14791:2017-04
122 Automated Measuring Systems (AMS) Hydrogen chloride concentration (HCl)
Range (0,087 – 200) mg/m3
Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Ion chromatography with conductometric detection (IC-CD) PN-EN 1911:2011
123 Automated Measuring Systems (AMS) Hydrogen chloride concentration (HCl)
Range (1,0 – 200) mg/m3
Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Spectrophotometric method PN-EN 1911:2011
124 Automated Measuring Systems (AMS) Concentration of hydrogen fluoride (HF)
Range (0,045 – 200) mg/m3
Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Ion chromatography with conductometric detection (IC-CD) ISO 15713:2006 CEN/TS 17340:2020
125 Automated Measuring Systems (AMS) Sampling for determination of total mercury concentration
Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
PN-EN 13211:2006
126 Automated Measuring Systems (AMS) Annual surveillance test (AST) for: N2O, NH3, CH4, HCHO PN-EN 14181:2015
127 Automated Measuring Systems (AMS) Calibration (QAL2) for: N2O, NH3, CH4, HCHO PN-EN 14181:2015
128 Automated Measuring Systems (AMS) Nitrous oxide concentration
Range (1,6 – 150) mg/m3
Non-dispersive infrared spectrometry (NDIR) PN-EN ISO 21258:2010
129 Automated Measuring Systems (AMS) Ammonia concentration
Range (0,04 – 200) mg/m3
Ion chromatography with conductometric detection (IC-CD) PN-EN ISO 21877:2020-03
130 Automated Measuring Systems (AMS) Methane concentration
Range (0,0012 – 0,3) %
Gas chromatography with flame ionization detection (GC-FID) PN-EN ISO 25139:2011
131 Automated Measuring Systems (AMS) Formaldehyde concentration
Range (0,034 – 50) mg/m3
High-performance liquid chromatography with diode array detection (HPLC-DAD) CEN/TS 17638:2021
132 Waste gases Gas volume flow rate for dynamic pressures > 5 Pa
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
Differential pressure measurement method PN-EN 16911-1:2013-07 CEN/TR 17078:2017
133 Waste gases Gas volume flow rate for dynamic pressures > 5 Pa
Velocity Range (0,4 – 15) m/s
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
Stagnation pressure method; Thermoanemometric method PN-Z-04030-7:1994
134 Waste gases Sampling for determination of dust concentration
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
PN-Z-04030-7:1994
135 Waste gases Dust concentration
Range (0,001 – 5) g/m3
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
Gravimetric method PN-Z-04030-7:1994
136 Waste gases Dust emission (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
PN-Z-04030-7:1994
137 Waste gases Sampling for determination of dust concentration
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
PN-EN 13284-1:2018-2
138 Waste gases Dust concentration
Range (0,5 – 50) mg/m3
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
Gravimetric method PN-EN 13284-1:2018-2
139 Waste gases Dust emission (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
PN-EN 13284-1:2018-2
140 Waste gases Concentration of oxygen, nitrogen oxides, sulphur dioxide, carbon dioxide, carbon monoxide
O2 (1 – 20,9) % NOx (1,4 – 2050) mg/m3 NO (0,7 – 1340) mg/m3 NOx (2,05 – 2050) mg/m3 NO (1,3 – 1340) mg/m3 SO2 (2,86 – 2000) mg/m3 CO2 (0,1 – 25) % CO (0,8 – 6250) mg/m3
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
Paramagnetic method; Chemiluminescence method; Non-dispersive infrared spectrometry method (NDIR); Non-dispersive infrared spectrometry method (NDIR) PN-ISO 10396:2001
141 Waste gases Emission of NOx (NO and NO2 calculated as NO2), NO and NO2, SO2, CO2, CO (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
PN-ISO 10396:2001
142 Waste gases Oxygen concentration
Range (1 – 20,9) %
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
Paramagnetic method PN-EN 14789:2017-04
143 Waste gases Carbon dioxide concentration
Range (0,1 – 25) %
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
Non-dispersive infrared spectrometry (NDIR) ISO 12039:2019
144 Waste gases Concentration of nitrogen oxides, nitrogen monoxide
NOx (1,4 – 2050) mg/m3 NO (0,7 – 1340) mg/m3
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
Chemiluminescence method PN-EN 14792:2017-04
145 Waste gases Emission of NOx (NO and NO2 calculated as NO2), NO, NO2 (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
PN-EN 14792:2017-04
146 Waste gases Carbon monoxide concentration
Range (0,8 – 6250) mg/m3
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
Non-dispersive infrared spectrometry (NDIR) PN-EN 15058:2017-04
147 Waste gases Carbon monoxide emission (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
PN-EN 15058:2017-04
148 Waste gases Water vapour concentration (H2O)
Range (23 – 250) g/m3 Range (3 – 40) % Range (3,14 – 57,41) %
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
Condensation-adsorption method; Temperature method PN-EN 14790:2017-04
149 Waste gases Concentration of organic substances in the form of gases and vapours expressed as total gaseous organic carbon
Range (1,0 – 1000) mg/m3
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
Continuous flame ionization detection method (FID) PN-EN 12619:2013-05
150 Waste gases Emission of organic substances in gaseous and vapour form expressed as total gaseous organic carbon (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
PN-EN 12619:2013-05
151 Waste gases Sampling for the determination of PCDD/PCDF mass concentration
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
PN-EN 1948-1:2006
152 Waste gases PCDD/PCDF emission (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
PN-EN 1948-1:2006
153 Waste gases Sampling for determination of metal concentrations: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
PN-EN 14385:2025-05
154 Waste gases Emission of metals: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
PN-EN 14385:2025-05
155 Waste gases Sampling for determination of total mercury concentration
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
PN-EN 13211:2006
156 Waste gases Total mercury emission (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
PN-EN 13211:2006
157 Waste gases Sampling for determination of SO2 concentration
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
PN-EN 14791:2017-04
158 Waste gases SO2 emission (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
PN-EN 14791:2017-04
159 Waste gases Sampling for determination of hydrogen chloride concentration
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
PN-EN 1911:2011
160 Waste gases Emission of hydrogen chloride (HCl) (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
PN-EN 1911:2011
161 Waste gases Sampling for the determination of the concentration of hydrogen fluoride, fluorine, fluorides (HF, F, F−)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
ISO 15713:2006 CEN/TS 17340:2020
162 Waste gases Emission of hydrogen fluoride, fluorine, fluorides (HF, F, F−) (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
ISO 15713:2006 CEN/TS 17340:2020
163 Waste gases Sampling for the determination of organic compound concentration
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
PN-Z-04008-4:1999
164 Waste gases Emission of organic compounds (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
PN-Z-04008-4:1999
165 Waste gases Sampling for determination of the concentration of individual gaseous organic compounds
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
PN-EN 13649:2005 CEN/TS 13649:2014
166 Waste gases Emission of individual gaseous organic compounds / sum of aromatic hydrocarbons / sum of aliphatic hydrocarbons (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
PN-EN 13649:2005 CEN/TS 13649:2014
167 Waste gases, General environment E - waste gas samples Concentration / content of individual gaseous organic compounds
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law Flexible scope of accreditation E E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005 CEN/TS 13649
168 Waste gases, General environment E - waste gas samples Concentration / content of organic and inorganic compounds
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law Flexible scope of accreditation E E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body.
Ion chromatography with conductometric detection (IC-CD) Standards, test procedures
169 Waste gases, General environment E - waste gas samples Concentration / content of inorganic compounds
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law Flexible scope of accreditation E E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body.
Thoron method Standards
170 Waste gases, General environment E - waste gas samples Concentration / content of hydrogen chloride (HCl)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law Flexible scope of accreditation E E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body.
Spectrophotometric method PN-EN 1911
171 Waste gases Nitrous oxide concentration
Range (1,6 – 150) mg/m3
Non-dispersive infrared spectrometry (NDIR) PN-EN ISO 21258:2010
172 Waste gases N2O emission (calculated) PN-EN ISO 21258:2010
173 Waste gases Sampling for determination of dust concentration, PM 2,5 and PM 10 PN-EN ISO 23210:2010
174 Waste gases PM 2,5 and PM 10 dust concentration
Range (1 – 40) mg/m3
Gravimetric method (impaction) PN-EN ISO 23210:2010
175 Waste gases PM 2,5 and PM 10 dust emission (calculated) PN-EN ISO 23210:2010
176 Waste gases Sampling for the determination of the mass concentration of dioxin-like PCBs, brominated flame retardants (BFR), polybrominated dibenzo-p-dioxins/furans (PBDD/F) PN-EN 1948-1:2006 | PN-EN 1948-4+A1:2014-03
177 Waste gases Emission of PCB, BFR, PBDD/F (calculated) PN-EN 1948-1:2006 | PN-EN 1948-4+A1:2014-03
178 Waste gases Sampling for the determination of isocyanate concentration US EPA conditional test method (CTM) 036:2005
179 Waste gases Isocyanate emission (calculated) US EPA conditional test method (CTM) 036:2005
180 Waste gases Sampling for determination of formaldehyde concentration CEN/TS 17638:2021
181 Waste gases Formaldehyde emission (calculated) CEN/TS 17638:2021
182 Waste gases Sampling for determination of the mass concentration of polycyclic aromatic hydrocarbons (PAH) Filtration-condensation-adsorption method ISO 11338-1:2003
183 Waste gases PAH emission (calculated) ISO 11338-1:2003
184 Waste gases Sampling for the determination of the concentration of sulphuric acid, including sulphuric acid mist and sulphur trioxide US EPA method 8 issue of 14.01.2019
185 Waste gases Emission of sulphuric acid, including sulphuric acid mist and sulphur trioxide (calculated) US EPA method 8 issue of 14.01.2019
186 Waste gases Sampling for determination of hydrogen sulphide concentration US EPA method 11 issue of 03.08.2017
187 Waste gases Hydrogen sulphide emission (calculated) US EPA method 11 issue of 03.08.2017
188 Waste gases Sampling for the determination of the concentration of hydrogen chloride, hydrogen bromide, hydrogen fluoride, chlorine, bromine. US EPA method 26 issue of 14.01.2019 US EPA method 26A issue of 14.01.2019
189 Waste gases Emission of hydrogen chloride, hydrogen bromide, hydrogen fluoride, chlorine, bromine. (calculated) US EPA method 26 issue of 14.01.2019 US EPA method 26A issue of 14.01.2019
190 Waste gases Sampling for determination of ammonia concentration PN-EN ISO 21877:2020-03
191 Waste gases Ammonia emission (calculated) PN-EN ISO 21877:2020-03
192 Waste gases Sampling for the determination of selenium concentration ISO 17211:2015
193 Waste gases Emission of selenium (calculated) ISO 17211:2015
194 Waste gases Sampling for the determination of organic compound concentration
Tedlar
Aspiration method using bags Test procedure PB-94 issue 3 of 17.09.2021
195 Waste gases Emission of organic compounds (calculated) Test procedure PB-94 issue 3 of 17.09.2021
196 Waste gases Sampling for determination of the concentration of individual gaseous organic compounds EPA – Method 18:2019
197 Waste gases Emission of individual gaseous organic compounds (calculated) EPA – Method 18:2019
198 Waste gases Sampling for the determination of methane concentration PN-EN ISO 25139:2011
199 Waste gases Methane emission (calculated) PN-EN ISO 25139:2011
200 Waste gases Sampling for the determination of the concentration of metals: Sn, Fe, Zn, Mg, Al, Cr (III), Cr(VI), Ca, Cd, Mn, Cu, Pb, Cr, Ni, B, Be, Ba, Bi, Mo, Tl, As, Sb, Co, Ti, Ag, V, benzo(a)pyrene Test procedure PB-11 issue 1 of 15.06.2023
201 Waste gases Emission of metals: Sn, Fe, Zn, Mg, Al, Cr(III), Cr(VI), Ca , Cd, Mn, Cu, Pb, Cr, Ni, B, Be, Ba, Bi, Mo, Tl, As, Sb, Co, Ti, Ag, V, benzo(a)pyrene (calculated) Test procedure PB-11 issue 1 of 15.06.2023
202 Waste gases Sampling for the determination of the concentration of sulphuric acid and SO3, phenol, ozone, hydrogen sulphide, chlorine, nitrogen oxide, nitrogen dioxide, formaldehyde., Samples collected on filters and/or in absorption solutions Test procedure PB-EM-01 issue 1 of 02.08.2026
203 Waste gases Emission of sulphuric acid and SO3, phenol, ozone, hydrogen sulphide, chlorine, nitrogen oxide, nitrogen dioxide, formaldehyde (calculated) Test procedure PB-EM-01 issue 1 of 02.08.2026
204 Waste gases, General environment E – waste gas samples collected on filters and sorbent tubes, condensate samples and absorbing solution samples Concentration / content of organic compounds
Regulated area: Flexible scope of accreditation E E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body.
High-performance liquid chromatography with fluorescence detection (HPLC-FLD); High-performance liquid chromatography with diode array detection (HPLC-DAD) Standards
205 Waste gases, General environment E – waste gas samples collected on filters and sorbent tubes, condensate samples and absorbing solution samples Concentration / content of polycyclic aromatic hydrocarbons (PAH)
Regulated area: Flexible scope of accreditation E E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body.
High-performance liquid chromatography with fluorescence detection (HPLC-FLD); High-performance liquid chromatography with diode array detection (HPLC-DAD) Standards
206 Waste gases, General environment E - waste gas samples collected on filters and sorbent tubes, condensate samples and absorbing solution samples Concentration / content of isocyanates
Regulated area: Flexible scope of accreditation E E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body.
High-performance liquid chromatography with fluorescence detection (HPLC-FLD) Standards, test procedures
207 Waste gases, General environment E – waste gas samples collected on filters and sorbent tubes, condensate samples and absorbing solution samples Concentration / content of organic and inorganic compounds
Regulated area: Flexible scope of accreditation E E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body.
Ion chromatography with conductometric detection (IC-CD) Standards, test procedures
208 Waste gases, General environment E – waste gas samples collected on filters and sorbent tubes, condensate samples and absorbing solution samples Concentration / content of amines
Regulated area: Flexible scope of accreditation E E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body.
Ion chromatography with conductometric detection (IC-CD) Standards, test procedures
209 Waste gases, General environment E – waste gas samples collected on filters and sorbent tubes, condensate samples and absorbing solution samples Concentration / content of inorganic compounds
Regulated area: Flexible scope of accreditation E E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body.
Titrimetric / thoron method Standards, test procedures
210 Waste gases, General environment E - waste gas samples Concentration / content of metals
Regulated area: Flexible scope of accreditation E E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body.
Flame atomic absorption spectrometry (FAAS) Test procedures
211 Waste gases, General environment E - waste gas samples Concentration / content of individual gaseous organic compounds
Regulated area: Flexible scope of accreditation E E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Standards
212 Waste gases, General environment E - waste gas samples Ammonia concentration / content
Regulated area: Flexible scope of accreditation E E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body.
Spectrophotometric method PN-EN ISO 21877
213 Waste gases, General environment E - waste gas samples Concentration / content of chromium (VI)
Regulated area: Flexible scope of accreditation E E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body.
Spectrophotometric method Test procedure PB-95
214 Waste gases, General environment E - waste gas samples Concentration / content of ozone
Regulated area: Flexible scope of accreditation E E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body.
Spectrophotometric method Test procedure PB-82
215 Waste gases, General environment E - waste gas samples Concentration/ content of formaldehyde
Regulated area: Flexible scope of accreditation E E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body.
Spectrophotometric method Test procedure PB-54
216 Waste gases, General environment E - waste gas samples Hydrogen sulphide concentration / content
Regulated area: Flexible scope of accreditation E E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body.
Spectrophotometric method Test procedure PB-96
217 Waste gases, General environment E - waste gas samples Chlorine concentration / content
Regulated area: Flexible scope of accreditation E E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body.
Spectrophotometric method Test procedure PB-57
218 Waste gases, General environment E - waste gas samples Phenol concentration / content
Regulated area: Flexible scope of accreditation E E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body.
Spectrophotometric method Test procedure PB-53
219 Waste gases, General environment E - waste gas samples Concentration / content of nitrogen oxide and nitrogen dioxide
Regulated area: Flexible scope of accreditation E E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body.
Spectrophotometric method PN-Z-04009-11
220 Waste gases, General environment E - waste gas samples Concentration / content of sulphur dioxide
Regulated area: Flexible scope of accreditation E E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body.
Spectrophotometric method PN-Z-04015-12
221 Wastewater E, Meltwater, Rainwater Sampling for chemical and physical testing
Temperature Range (0,0 – 50,0) °C
Regulated area: Flexible scope of accreditation E E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body.
Manual method PN-ISO 5667-10 | PN-77/C-04584
222 Wastewater E pH
Range 4,0 – 10,0
Regulated area: Flexible scope of accreditation E E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body.
Potentiometric method PN-EN ISO 10523
223 Wastewater E Metal concentrations
Regulated area: Flexible scope of accreditation E E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is made publicly available by the accredited body.
Flame atomic absorption spectrometry (FAAS) PN-ISO 8288 Method A

Reference standards (106)

CEN/TS 17638:2021
EPA – Method 18:2019
ISO 11338-1:2003
ISO 12039:2019
ISO 15713:2006 CEN/TS 17340:2020
ISO 17211:2015
Working instruction No. IR-C1 issue 4 of 21.04.2024
NIOSH 7400, Issue 3
Standards
Standards, test procedures
PB-01-1 issue 1 of 05.04.2023
PB-01-2 issue 1 of 24.02.2026
PB-46 issue 3 of 05.04.2023
PB-65 issue 3 of 19.06.2023
PB-92 issue 2 of 19.06.2023
PN-70/Z-04044
PN-71/Z-04041
PN-75/Z-04037/03
PN-75/Z-04093/02
PN-76/Z-04045/02
PN-77/C-04584
PN-87/Z-04126/03
PN-93/Z-04225/03
PN-EN 12619:2013-05
PN-EN 13211:2006
PN-EN 13284-1:2018-2
PN-EN 13649:2005 CEN/TS 13649
PN-EN 13649:2005 CEN/TS 13649:2014
PN-EN 14181:2015
PN-EN 14253+A1:2011
PN-EN 14255-1:2010
PN-EN 14255-2:2010
PN-EN 14385:2025-05
PN-EN 14789:2017-04
PN-EN 14790:2017-04
PN-EN 14791:2017-04
PN-EN 14792:2017-04
PN-EN 15058:2017-04
PN-EN 16911-1:2013-07 CEN/TR 17078:2017
PN-EN 1911
PN-EN 1911:2011
PN-EN 1948-1:2006
PN-EN 1948-4+A1:2014-03
PN-EN ISO 10523
PN-EN ISO 11079:2008
PN-EN ISO 21258:2010
PN-EN ISO 21877
PN-EN ISO 21877:2020-03
PN-EN ISO 23210:2010
PN-EN ISO 25139:2011
PN-EN ISO 3744:2011 excluding cl. 8.3
PN-EN ISO 3746:2011+Ap1:2017-09 excluding cl. 8.4
PN-EN ISO 5349-1:2004
PN-EN ISO 5349-2:2004
PN-EN ISO 5349-2:2004/A1:2015-11
PN-EN ISO 7243:2018-01
PN-EN ISO 7243:2018-01/Ap2:2020-04
PN-EN ISO 7730:2006
PN-EN ISO 7730:2006/Ap2:2016-04
PN-EN ISO 9612:2025-11
PN-ISO 10396:2001
PN-ISO 5667-10
PN-ISO 8288 Method A
PN-N-01307:1994
PN-SO 9613-2:2002
PN-T-05687:2002 cl. 2.5.5
PN-T-06580-3:2002 Method adapted to the regulated area
PN-Z-01339:2020-12
PN-Z-04007-2
PN-Z-04008-4:1999
PN-Z-04008-7:2002 + Az1:2004
PN-Z-04009-11
PN-Z-04015-12
PN-Z-04015-13
PN-Z-04030-7:1994
PN-Z-04073-1
PN-Z-04108-5:2006
PN-Z-04507:2022-05
PN-Z-04507:2022-05/Ap1:2022-08
PN-Z-04508:2022-05
PN-Z-04508:2022-05/Ap1:2022-08
PN-Z-04548:2023-03
Principles and Methods of Assessing the Working Environment
Principles and Methods of Assessing the Working Environment 2012, issue 4 (74), pp. 117-130
Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 151–180
Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 91–150
Principles and Methods of Assessing the Working Environment 2017, No. 2 (92), pp. 89–131
Test procedure PB-11 issue 1 of 15.06.2023
Test procedure PB-53
Test procedure PB-54
Test procedure PB-57
Test procedure PB-82
Test procedure PB-94 issue 3 of 17.09.2021
Test procedure PB-95
Test procedure PB-96
Test procedure PB-EM-01 issue 1 of 02.08.2026
Test procedures
Clause 3 of the Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630)
Clause 3 of the Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022, item 2630)
US EPA conditional test method (CTM) 036:2005
US EPA method 11 issue of 03.08.2017
US EPA method 26 issue of 14.01.2019 US EPA method 26A issue of 14.01.2019
US EPA method 8 issue of 14.01.2019
Page version: A
Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630)
Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023, item 1706)

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/PL/AB%20409