🇵🇱 EKOPERFEX PL

PCA AB 408 • Słupsk, Poland • 33 methods

EnvironmentConstruction

EKOPERFEX is a laboratory accredited by PCA under number AB 408 (Słupsk, Poland). Its accreditation scope covers 33 test methods in the following areas: Environment, Construction. Test objects include: Workplace environment - air, Workplace environment - emergency lighting, Workplace environment - electromagnetic field, General environment - noise from installations, equipment and indus…. Most frequently used techniques: Direct measurement method, Gravimetric method, Personal dosimetry method.

At a glance

  • Accreditation number: PCA AB 408
  • Methods in scope: 33
  • Types of test objects: 13
  • Techniques used: 5
  • City: Słupsk, Poland
Accreditation number
AB 408
Accreditation body
PCA
Address
Przemysław Kubina, LABORATORIUM BADAŃ ŚRODOWISKOWYCH, ul. Portowa 13b, 76-200 Słupsk
City
Słupsk, Poland

What this laboratory tests (13)

Analytical techniques used (5)

Laboratory locations

Certificate information

Issue date
30.07.2026
Issue no.
29

Accreditation scope — test methods (33)

No. Test object Methodology / Parameters Technique Reference document
Environmental Testing Laboratory
1 Workplace environment - air Air sampling for occupational exposure assessment to: dust agents – inhalable fraction – respirable fraction Personal dosimetry method PN-Z-04008-7:2002+ Az1:2004
2 Workplace environment - air Sampling of air for the assessment of occupational exposure to: organic substances, including – inhalable fraction inorganic substances, including – inhalable fraction – respirable fraction metals and their compounds, including – inhalable fraction – respirable fraction Personal dosimetry method PN-Z-04008-7:2002+ Az1:2004
3 Workplace environment - air Exposure index (calculated) PN-Z-04008-7:2002+ Az1:2004
4 Workplace environment - air Concentration of harmful dust agents – inhalable fraction
apatites and phosphorites portland cement titanium dioxide natural graphite synthetic graphite kaolin amorphous and synthetic silica wood dusts flour dusts dusts not classified according to toxicity organic dusts of animal and plant origin, excluding wood and flour dusts carbon black calcium sulfate (VI) (gypsum) talc coal (hard, brown) calcium magnesium carbonate (dolomite) silicon carbide, non-fibrous Range (0,10 – 20,83) mg/m3
Gravimetric method PN-Z-04507:2022-05 | PN-Z-04507:2022-05+Ap1:2022-08
5 Workplace environment - air Concentration of harmful dust agents – respirable fraction
apatites and phosphorites portland cement natural graphite amorphous and synthetic silica organic dusts of animal and plant origin, excluding wood and flour dusts talc coal (hard, brown) Range (0,10 – 21,93) mg/m3
Gravimetric method PN-Z-04508:2022-05 | PN-Z-04508:2022-05+Ap1:2022-08
6 Workplace environment - air Carbon monoxide concentration
Range (2,32 – 232) mg/m3 Range (2 – 200) ppm
Electrochemical method PB-034 issue 3 of 03.07.2025
7 Workplace environment - air Exposure indices (calculated) PB-034 issue 3 of 03.07.2025
8 Workplace environment - indoor electric lighting Illuminance
Range (5 – 9000) lx
Direct measurement method PB-001 issue 3 of 25.06.2026
9 Workplace environment - indoor electric lighting Illuminance uniformity (calculated) PB-001 issue 3 of 25.06.2026
10 Workplace environment - emergency lighting Illuminance
Range (0,5 – 500) lx
Direct measurement method PN-EN 1838:2013-11 excluding cl. 4.2.3, 4.2.4, 4.2.7, 4.3.3, 4.3.4, 4.3.7, 4.3.9, 4.4, 4.5, 5
11 Workplace environment - emergency lighting Ratio of minimum to maximum illuminance (calculated) PN-EN 1838:2013-11 excluding cl. 4.2.3, 4.2.4, 4.2.7, 4.3.3, 4.3.4, 4.3.7, 4.3.9, 4.4, 4.5, 5
12 Workplace environment - emergency lighting Closing time
Range (1 – 60) s
Direct measurement method PN-EN 1838:2013-11 excluding cl. 4.2.3, 4.2.4, 4.2.7, 4.3.3, 4.3.4, 4.3.7, 4.3.9, 4.4, 4.5, 5
13 Workplace environment - emergency lighting Minimum duration of lighting operation
Range (1 - 3600) s
Direct measurement method PN-EN 1838:2013-11 excluding cl. 4.2.3, 4.2.4, 4.2.7, 4.3.3, 4.3.4, 4.3.7, 4.3.9, 4.4, 4.5, 5
14 Workplace environment - hot microclimate Air temperature
Range (20 – 40) °C Natural wet bulb temperature Range (20 – 40) °C Black globe temperature Range (20 – 40) °C
Direct measurement method PN-EN ISO 7243:2018-01
15 Workplace environment - hot microclimate WBGT index, WBGTeff index (calculated) PN-EN ISO 7243:2018-01
16 Workplace environment - cold microclimate Air temperature
Range (-30 – 10) °C Black globe temperature Range (-30 – 10) °C Air humidity Range (20 – 90) % Air velocity Range (0,15 – 5,00) m/s
Direct measurement method PN-EN ISO 11079:2008+Ap1:2013-10
17 Workplace environment - cold microclimate IREQ min index, IREQ neutral index, tWC index (calculated) PN-EN ISO 11079:2008+Ap1:2013-10
18 Workplace environment - moderate microclimate Air temperature
Range (-30 – 10) °C Black globe temperature Range (-30 – 10) °C Air humidity Range (20 – 90) % Air velocity Range (0,15 – 5,00) m/s
Direct measurement method PN-EN ISO7730:2006+Ap2:2016-04P
19 Workplace environment - moderate microclimate PMV index, PPD index (calculated) PN-EN ISO7730:2006+Ap2:2016-04P
20 Workplace environment - noise A-weighted equivalent sound level Maximum A-weighted sound level
Range (44 - 136) dB C-weighted peak sound pressure level Range (44 - 136) dB
Direct measurement method PN-N-01307:1994 | PN-EN ISO 9612:2011 excluding the method covering strategies 2 and 3 – cl. 10 and 11.
21 Workplace environment - noise Noise exposure level referred to:
an 8-hour daily working time the average weekly working time (calculated)
PN-N-01307:1994 | PN-EN ISO 9612:2011 excluding the method covering strategies 2 and 3 – cl. 10 and 11.
22 Workplace environment - hand-arm vibration Frequency-weighted r.m.s. vibration acceleration
Range (0,06 – 100) m/s2
Direct measurement method PN-EN-ISO 5349-1:2004 | PN-EN-ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11
23 Workplace environment - hand-arm vibration Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the vector sum of the r.m.s. frequency-corrected vibration accelerations determined for three directional components (ahwx, ahwy, ahwz), Exposure lasting 30 minutes or less, expressed as the vector sum of the r.m.s. frequency-weighted vibration accelerations determined for three directional components (ahwx, ahwy, ahwz) (calculated) PN-EN-ISO 5349-1:2004 | PN-EN-ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11
24 Workplace environment - whole-body vibration Frequency-weighted r.m.s. vibration acceleration
Range (0,07 – 100) m/s2
Direct measurement method PN-EN 14253+A1:2011
25 Workplace environment - whole-body vibration Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the r.m.s. frequency-corrected vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz), Exposure lasting 30 minutes or less, expressed as the r.m.s. frequency-weighted vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz) (calculated) PN-EN 14253+A1:2011
26 Workplace environment - ultrasonic noise Equivalent sound pressure level in one-third octave bands with centre frequencies from 10 kHz to 40 kHz Maximum sound pressure level in one-third octave bands with centre frequencies from 10 kHz to 40 kHz
Range (64 - 158) dB
Direct measurement method PN-Z-01339-2020-12
27 Workplace environment - ultrasonic noise Equivalent sound pressure level in one-third octave bands with centre frequencies from 10 kHz to 40 kHz referred to:
an 8-hour daily working time the average weekly working time (calculated)
PN-Z-01339-2020-12
28 General environment - noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level
Range (24 - 136) dB
Direct measurement method Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023, item 1706) excluding cl. F
29 General environment - noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023, item 1706) excluding cl. F
30 Workplace environment - electromagnetic field in the workspace from magnetotherapy devices Magnetic flux density
in the frequency range from 10 to 400 x 103 Hz Range 1 μT – 20 mT
Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (consolidated text: Journal of Laws of 2018, item 331)
Direct measurement method (simplified) Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 151–180
31 Workplace environment - electromagnetic field Electric field strength in the frequency range: from 5 Hz to 29 * 106 Hz
Range 1 V/m – 50 kV/m
Direct measurement method PN-T-06580-3:2002 Method adapted to the regulated area
32 Workplace environment - electromagnetic field Magnetic field strength in the frequency range: from 10 * 103 Hz to 29 * 106 Hz
Range (0,01 – 200) A/m
Direct measurement method PN-T-06580-3:2002 Method adapted to the regulated area
33 Workplace environment - electromagnetic field Magnetic flux density in the frequency range:
0 Hz Range 0,1 mT – 1T 10Hz – 500 * 103 Hz Range 1 μT – 20 mT
Direct measurement method PN-T-06580-3:2002 Method adapted to the regulated area

Reference standards (21)

PB-001 issue 3 of 25.06.2026
PB-034 issue 3 of 03.07.2025
PN-EN 14253+A1:2011
PN-EN 1838:2013-11 excluding cl. 4.2.3, 4.2.4, 4.2.7, 4.3.3, 4.3.4, 4.3.7, 4.3.9, 4.4, 4.5, 5
PN-EN ISO 11079:2008+Ap1:2013-10
PN-EN ISO 5349-2:2004/A1:2015-11
PN-EN ISO 7243:2018-01
PN-EN ISO 9612:2011 excluding the method covering strategies 2 and 3 – cl. 10 and 11.
PN-EN ISO7730:2006+Ap2:2016-04P
PN-EN-ISO 5349-1:2004
PN-EN-ISO 5349-2:2004
PN-N-01307:1994
PN-T-06580-3:2002 Method adapted to the regulated area
PN-Z-01339-2020-12
PN-Z-04008-7:2002+ Az1:2004
PN-Z-04507:2022-05
PN-Z-04507:2022-05+Ap1:2022-08
PN-Z-04508:2022-05
PN-Z-04508:2022-05+Ap1:2022-08
Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 151–180
Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023, item 1706) excluding cl. F

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/PL/AB%20408