🇵🇱 EkoAtom Krzysztof Wiśniewski PL
Environment
EkoAtom Krzysztof Wiśniewski is a laboratory accredited by PCA under number AB 365 (Leszno, Poland). Its accreditation scope covers 32 test methods in the following areas: Environment. Test objects include: Environment – electromagnetic field in the vicinity of radiocommuni…, Workplace environment − electromagnetic field, Environment – electromagnetic field in the vicinity of electric pow…, Workplace environment - electromagnetic field from power systems an…. Most frequently used techniques: Direct measurement method.
At a glance
- Accreditation number: PCA AB 365
- Methods in scope: 32
- Types of test objects: 18
- Techniques used: 1
- City: Leszno, Poland
- Accreditation number
- AB 365
- Accreditation body
- PCA
- Address
- ul. Iwaszkiewicza 17, 64-100 Leszno
- City
- Leszno, Poland
What this laboratory tests (18)
- Environment – electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) — 4 methods
- Workplace environment − electromagnetic field — 4 methods
- Environment – electromagnetic field in the vicinity of electric power substations and power lines — 3 methods
- Workplace environment - electromagnetic field from power systems and AC electrical supply installations in the power industry — 3 methods
- Workplace environment - electromagnetic field from transmitting devices of radiocommunication systems — 3 methods
- Workplace environment - electromagnetic field in the work space originating from magnetotherapy and magnetostimulation devices — 2 methods
- Workplace environment and general environment – ionising radiation — 2 methods
- Dental equipment – intraoral radiography units — 1 method
- Dental equipment – panoramic radiography and analogue cephalometry units — 1 method
- Dental equipment – panoramic radiography and digital cephalometry units — 1 method
- Environment – electromagnetic field in the vicinity of other installations — 1 method
- Equipment used in analogue mammography — 1 method
- Equipment used in dental cone beam computed tomography — 1 method
- Equipment used in digital mammography — 1 method
- Equipment used in fluoroscopy and angiography — 1 method
- and 3 more
Analytical techniques used (1)
- Direct measurement method — 14 methods
Certificate information
- Issue date
- 03.06.2026
- Issue no.
- 25
Accreditation scope — test methods (32)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Workplace environment - electromagnetic field from power systems and AC electrical supply installations in the power industry | Electric field strength: in the frequency range 5 Hz up to 100 kHz Range (1,0 − 50 000) V/m Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (consolidated text: Journal of Laws of 2018, item 331) |
Direct measurement method | Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 91–150 | |
| 2 | Workplace environment - electromagnetic field from power systems and AC electrical supply installations in the power industry | Magnetic flux density in the frequency range from 5 Hz up to 100 kHz Range (1,0 − 19 000) µT in the frequency range 0 Hz Range (0,1 – 1000) mT Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (consolidated text: Journal of Laws of 2018, item 331) |
Direct measurement method | Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 91–150 | |
| 3 | Workplace environment - electromagnetic field from power systems and AC electrical supply installations in the power industry | Magnetic field strength in the frequency range from 0 Hz up to 100 kHz (calculated) Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (consolidated text: Journal of Laws of 2018, item 331) |
Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 91–150 | ||
| 4 | Workplace environment - electromagnetic field in the work space originating from magnetotherapy and magnetostimulation devices | Electric field strength: in the frequency range from 5 Hz up to 100 kHz Range (1,0 − 50 000) V/m Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (consolidated text: Journal of Laws of 2018, item 331) |
Direct measurement method | Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 151–180 | |
| 5 | Workplace environment - electromagnetic field in the work space originating from magnetotherapy and magnetostimulation devices | Magnetic flux density in the frequency range from 5 Hz up to 100 kHz Range (1,0 – 19 000) µT Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (consolidated text: Journal of Laws of 2018, item 331) |
Direct measurement method | Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 151–180 | |
| 6 | Workplace environment - electromagnetic field from transmitting devices of radiocommunication systems | Electric field strength: in the frequency range from 200 kHz up to 60 GHz Range (0,7 – 100 000) V/m Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (consolidated text: Journal of Laws of 2018, item 331) |
Direct measurement method | Principles and Methods of Assessing the Working Environment 2017, No. 2 (92), pp. 89–131 | |
| 7 | Workplace environment - electromagnetic field from transmitting devices of radiocommunication systems | Magnetic field strength in the frequency range from 200 Hz up to 1 GHz Range (0,012 – 16) A/m Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (consolidated text: Journal of Laws of 2018, item 331) |
Direct measurement method | Principles and Methods of Assessing the Working Environment 2017, No. 2 (92), pp. 89–131 | |
| 8 | Workplace environment - electromagnetic field from transmitting devices of radiocommunication systems | Magnetic field strength in the frequency range from 800 MHz up to 60 GHz (calculated) Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (consolidated text: Journal of Laws of 2018, item 331) |
Principles and Methods of Assessing the Working Environment 2017, No. 2 (92), pp. 89–131 | ||
| 9 | Environment – electromagnetic field in the vicinity of electric power substations and power lines | Electric field strength: in the frequency range 50 Hz Range (1,0 - 50 000) V/m Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Direct measurement method | Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630) | |
| 10 | Environment – electromagnetic field in the vicinity of electric power substations and power lines | Magnetic flux density in the frequency range 50 Hz Range (1,0 – 19 000) µT Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Direct measurement method | Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630) | |
| 11 | Environment – electromagnetic field in the vicinity of electric power substations and power lines | Magnetic field strength in the frequency range 50 Hz (calculated) Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630) | ||
| 12 | Environment – electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) | Electric field strength: in the frequency range from 200 kHz up to 60 GHz Range (0,7 – 100 000) V/m Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Direct measurement method | Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630) | |
| 13 | Environment – electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) | Magnetic field strength: in the frequency range from 200 kHz up to 1 GHz Range (0,012 – 16) A/m Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Direct measurement method | Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630) | |
| 14 | Environment – electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) | Magnetic field strength: in the frequency range from 10 MHz up to 60 GHz (calculated) Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630) | ||
| 15 | Environment – electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) | Power density in the frequency range from 0,3 GHz up to 60 GHz (calculated) Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630) | ||
| 16 | Workplace environment − electromagnetic field | Electric field strength in the frequency range from 5 Hz to 60 GHz Range (0,7 − 50 000) V/m |
Direct measurement method | PN-T-06580-3:2002 Method adapted to the regulated area | PB-PEM-BHP issue 4 of 30.10.2018 | |
| 17 | Workplace environment − electromagnetic field | Magnetic field strength in the frequency range from 200 kHz to 1 GHz Range (0,012 – 16) A/m |
Direct measurement method | PN-T-06580-3:2002 Method adapted to the regulated area | PB-PEM-BHP issue 4 of 30.10.2018 | |
| 18 | Workplace environment − electromagnetic field | Magnetic field strength in the frequency range 0 Hz from 5 Hz up to 400 kHz from 800 MHz up to 60 GHz (calculated) |
PN-T-06580-3:2002 Method adapted to the regulated area | PB-PEM-BHP issue 4 of 30.10.2018 | ||
| 19 | Workplace environment − electromagnetic field | Magnetic flux density in the frequency range 0 Hz Range (0,1 − 1000) mT from 5 Hz up to 400 kHz Range (1,0 – 19 000) µT |
Direct measurement method | PN-T-06580-3:2002 Method adapted to the regulated area | PB-PEM-BHP issue 4 of 30.10.2018 | |
| 20 | Workplace environment and general environment – ionising radiation | Dose rate in the environment around the X-ray apparatus Range (0,000 µGy/s – 1000 mGy/s) (0,000 µSv/s – 1000 mSv/s) Direct measurement |
PrB-RTG R-F-S-M-O-D issue 3 of 28.12.2022 | ||
| 21 | Workplace environment and general environment – ionising radiation | Dose in the environment around the X-ray unit Range (0,000 µGy – 1000 mGy) (0,000 µSv – 1000 mSv) Direct/indirect measurement |
PrB-RTG R-F-S-M-O-D issue 3 of 28.12.2022 | ||
| 22 | Environment – electromagnetic field in the vicinity of other installations | Magnetic flux density in the frequency range 0 Hz Range (0,1 – 1000) mT |
Direct measurement method | Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630) | |
| 23 | Equipment used in general analogue radiography | Specialist tests | Annexes 1 and 2 to the Regulation of the Minister of Health of 12 December 2022 (Journal of Laws 2022 item 2759) | PrB-RTG R-F-S-M-O-D issue 3 of 28.12.2022 | ||
| 24 | Equipment used in general digital radiography | Specialist tests | Annexes 1 and 2 to the Regulation of the Minister of Health of 12 December 2022 (Journal of Laws 2022 item 2759) | PrB-RTG R-F-S-M-O-D issue 3 of 28.12.2022 | ||
| 25 | Dental equipment – panoramic radiography and analogue cephalometry units | Specialist tests | Annexes 1 and 2 to the Regulation of the Minister of Health of 12 December 2022 (Journal of Laws 2022 item 2759) | PrB-RTG R-F-S-M-O-D issue 3 of 28.12.2022 | ||
| 26 | Dental equipment – panoramic radiography and digital cephalometry units | Specialist tests | Annexes 1 and 2 to the Regulation of the Minister of Health of 12 December 2022 (Journal of Laws 2022 item 2759) | PrB-RTG R-F-S-M-O-D issue 3 of 28.12.2022 | ||
| 27 | Dental equipment – intraoral radiography units | Specialist tests | Annex 1 to the Regulation of the Minister of Health of 12 December 2022 (Journal of Laws 2022 item 2759) | PrB-RTG R-F-S-M-O-D issue 3 of 28.12.2022 | ||
| 28 | Equipment used in dental cone beam computed tomography | Specialist tests | Annex 1 to the Regulation of the Minister of Health of 12 December 2022 (Journal of Laws 2022 item 2759) | PrB-RTG R-F-S-M-O-D issue 3 of 28.12.2022 | ||
| 29 | Equipment used in fluoroscopy and angiography | Specialist tests | Annex 1 to the Regulation of the Minister of Health of 12 December 2022 (Journal of Laws 2022 item 2759) | PrB-RTG R-F-S-M-O-D issue 3 of 28.12.2022 | ||
| 30 | Equipment used in analogue mammography | Specialist tests | Annexes 1 and 2 to the Regulation of the Minister of Health of 12 December 2022 (Journal of Laws 2022 item 2759) | PrB-RTG R-F-S-M-O-D issue 3 of 28.12.2022 | ||
| 31 | Equipment used in digital mammography | Specialist tests | Annexes 1 and 2 to the Regulation of the Minister of Health of 12 December 2022 (Journal of Laws 2022 item 2759) | PrB-RTG R-F-S-M-O-D issue 3 of 28.12.2022 | ||
| 32 | Monitors used for the display of medical images | Specialist tests | Annex 2 to the Regulation of the Minister of Health of 12 December 2022 (Journal of Laws 2022 item 2759) | PrB-RTG R-F-S-M-O-D issue 3 of 28.12.2022 | ||
Reference standards (11)
PB-PEM-BHP issue 4 of 30.10.2018
PN-T-06580-3:2002 Method adapted to the regulated area
Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 151–180
Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 91–150
Principles and Methods of Assessing the Working Environment 2017, No. 2 (92), pp. 89–131
PrB-RTG R-F-S-M-O-D issue 3 of 28.12.2022
Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630)
Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630)
Annex 1 to the Regulation of the Minister of Health of 12 December 2022 (Journal of Laws 2022 item 2759)
Annexes 1 and 2 to the Regulation of the Minister of Health of 12 December 2022 (Journal of Laws 2022 item 2759)