🇵🇱 EkoAtom Krzysztof Wiśniewski PL

PCA AB 365 • Leszno, Poland • 32 methods

Environment

EkoAtom Krzysztof Wiśniewski is a laboratory accredited by PCA under number AB 365 (Leszno, Poland). Its accreditation scope covers 32 test methods in the following areas: Environment. Test objects include: Environment – electromagnetic field in the vicinity of radiocommuni…, Workplace environment − electromagnetic field, Environment – electromagnetic field in the vicinity of electric pow…, Workplace environment - electromagnetic field from power systems an…. Most frequently used techniques: Direct measurement method.

At a glance

  • Accreditation number: PCA AB 365
  • Methods in scope: 32
  • Types of test objects: 18
  • Techniques used: 1
  • City: Leszno, Poland
Accreditation number
AB 365
Accreditation body
PCA
Address
ul. Iwaszkiewicza 17, 64-100 Leszno
City
Leszno, Poland

What this laboratory tests (18)

Analytical techniques used (1)

Certificate information

Issue date
03.06.2026
Issue no.
25

Accreditation scope — test methods (32)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Workplace environment - electromagnetic field from power systems and AC electrical supply installations in the power industry Electric field strength:
in the frequency range 5 Hz up to 100 kHz Range (1,0 − 50 000) V/m
Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (consolidated text: Journal of Laws of 2018, item 331)
Direct measurement method Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 91–150
2 Workplace environment - electromagnetic field from power systems and AC electrical supply installations in the power industry Magnetic flux density
in the frequency range from 5 Hz up to 100 kHz Range (1,0 − 19 000) µT in the frequency range 0 Hz Range (0,1 – 1000) mT
Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (consolidated text: Journal of Laws of 2018, item 331)
Direct measurement method Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 91–150
3 Workplace environment - electromagnetic field from power systems and AC electrical supply installations in the power industry Magnetic field strength
in the frequency range from 0 Hz up to 100 kHz (calculated)
Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (consolidated text: Journal of Laws of 2018, item 331)
Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 91–150
4 Workplace environment - electromagnetic field in the work space originating from magnetotherapy and magnetostimulation devices Electric field strength:
in the frequency range from 5 Hz up to 100 kHz Range (1,0 − 50 000) V/m
Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (consolidated text: Journal of Laws of 2018, item 331)
Direct measurement method Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 151–180
5 Workplace environment - electromagnetic field in the work space originating from magnetotherapy and magnetostimulation devices Magnetic flux density
in the frequency range from 5 Hz up to 100 kHz Range (1,0 – 19 000) µT
Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (consolidated text: Journal of Laws of 2018, item 331)
Direct measurement method Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 151–180
6 Workplace environment - electromagnetic field from transmitting devices of radiocommunication systems Electric field strength:
in the frequency range from 200 kHz up to 60 GHz Range (0,7 – 100 000) V/m
Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (consolidated text: Journal of Laws of 2018, item 331)
Direct measurement method Principles and Methods of Assessing the Working Environment 2017, No. 2 (92), pp. 89–131
7 Workplace environment - electromagnetic field from transmitting devices of radiocommunication systems Magnetic field strength
in the frequency range from 200 Hz up to 1 GHz Range (0,012 – 16) A/m
Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (consolidated text: Journal of Laws of 2018, item 331)
Direct measurement method Principles and Methods of Assessing the Working Environment 2017, No. 2 (92), pp. 89–131
8 Workplace environment - electromagnetic field from transmitting devices of radiocommunication systems Magnetic field strength
in the frequency range from 800 MHz up to 60 GHz (calculated)
Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (consolidated text: Journal of Laws of 2018, item 331)
Principles and Methods of Assessing the Working Environment 2017, No. 2 (92), pp. 89–131
9 Environment – electromagnetic field in the vicinity of electric power substations and power lines Electric field strength:
in the frequency range 50 Hz Range (1,0 - 50 000) V/m
Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Direct measurement method Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630)
10 Environment – electromagnetic field in the vicinity of electric power substations and power lines Magnetic flux density
in the frequency range 50 Hz Range (1,0 – 19 000) µT
Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Direct measurement method Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630)
11 Environment – electromagnetic field in the vicinity of electric power substations and power lines Magnetic field strength
in the frequency range 50 Hz (calculated)
Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630)
12 Environment – electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) Electric field strength:
in the frequency range from 200 kHz up to 60 GHz Range (0,7 – 100 000) V/m
Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Direct measurement method Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630)
13 Environment – electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) Magnetic field strength:
in the frequency range from 200 kHz up to 1 GHz Range (0,012 – 16) A/m
Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Direct measurement method Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630)
14 Environment – electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) Magnetic field strength:
in the frequency range from 10 MHz up to 60 GHz (calculated)
Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630)
15 Environment – electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) Power density
in the frequency range from 0,3 GHz up to 60 GHz (calculated)
Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630)
16 Workplace environment − electromagnetic field Electric field strength in the frequency range from 5 Hz to 60 GHz
Range (0,7 − 50 000) V/m
Direct measurement method PN-T-06580-3:2002 Method adapted to the regulated area | PB-PEM-BHP issue 4 of 30.10.2018
17 Workplace environment − electromagnetic field Magnetic field strength in the frequency range from 200 kHz to 1 GHz
Range (0,012 – 16) A/m
Direct measurement method PN-T-06580-3:2002 Method adapted to the regulated area | PB-PEM-BHP issue 4 of 30.10.2018
18 Workplace environment − electromagnetic field Magnetic field strength in the frequency range 0 Hz
from 5 Hz up to 400 kHz from 800 MHz up to 60 GHz (calculated)
PN-T-06580-3:2002 Method adapted to the regulated area | PB-PEM-BHP issue 4 of 30.10.2018
19 Workplace environment − electromagnetic field Magnetic flux density in the frequency range 0 Hz
Range (0,1 − 1000) mT from 5 Hz up to 400 kHz Range (1,0 – 19 000) µT
Direct measurement method PN-T-06580-3:2002 Method adapted to the regulated area | PB-PEM-BHP issue 4 of 30.10.2018
20 Workplace environment and general environment – ionising radiation Dose rate in the environment around the X-ray apparatus
Range (0,000 µGy/s – 1000 mGy/s) (0,000 µSv/s – 1000 mSv/s) Direct measurement
PrB-RTG R-F-S-M-O-D issue 3 of 28.12.2022
21 Workplace environment and general environment – ionising radiation Dose in the environment around the X-ray unit
Range (0,000 µGy – 1000 mGy) (0,000 µSv – 1000 mSv) Direct/indirect measurement
PrB-RTG R-F-S-M-O-D issue 3 of 28.12.2022
22 Environment – electromagnetic field in the vicinity of other installations Magnetic flux density in the frequency range 0 Hz
Range (0,1 – 1000) mT
Direct measurement method Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630)
23 Equipment used in general analogue radiography Specialist tests Annexes 1 and 2 to the Regulation of the Minister of Health of 12 December 2022 (Journal of Laws 2022 item 2759) | PrB-RTG R-F-S-M-O-D issue 3 of 28.12.2022
24 Equipment used in general digital radiography Specialist tests Annexes 1 and 2 to the Regulation of the Minister of Health of 12 December 2022 (Journal of Laws 2022 item 2759) | PrB-RTG R-F-S-M-O-D issue 3 of 28.12.2022
25 Dental equipment – panoramic radiography and analogue cephalometry units Specialist tests Annexes 1 and 2 to the Regulation of the Minister of Health of 12 December 2022 (Journal of Laws 2022 item 2759) | PrB-RTG R-F-S-M-O-D issue 3 of 28.12.2022
26 Dental equipment – panoramic radiography and digital cephalometry units Specialist tests Annexes 1 and 2 to the Regulation of the Minister of Health of 12 December 2022 (Journal of Laws 2022 item 2759) | PrB-RTG R-F-S-M-O-D issue 3 of 28.12.2022
27 Dental equipment – intraoral radiography units Specialist tests Annex 1 to the Regulation of the Minister of Health of 12 December 2022 (Journal of Laws 2022 item 2759) | PrB-RTG R-F-S-M-O-D issue 3 of 28.12.2022
28 Equipment used in dental cone beam computed tomography Specialist tests Annex 1 to the Regulation of the Minister of Health of 12 December 2022 (Journal of Laws 2022 item 2759) | PrB-RTG R-F-S-M-O-D issue 3 of 28.12.2022
29 Equipment used in fluoroscopy and angiography Specialist tests Annex 1 to the Regulation of the Minister of Health of 12 December 2022 (Journal of Laws 2022 item 2759) | PrB-RTG R-F-S-M-O-D issue 3 of 28.12.2022
30 Equipment used in analogue mammography Specialist tests Annexes 1 and 2 to the Regulation of the Minister of Health of 12 December 2022 (Journal of Laws 2022 item 2759) | PrB-RTG R-F-S-M-O-D issue 3 of 28.12.2022
31 Equipment used in digital mammography Specialist tests Annexes 1 and 2 to the Regulation of the Minister of Health of 12 December 2022 (Journal of Laws 2022 item 2759) | PrB-RTG R-F-S-M-O-D issue 3 of 28.12.2022
32 Monitors used for the display of medical images Specialist tests Annex 2 to the Regulation of the Minister of Health of 12 December 2022 (Journal of Laws 2022 item 2759) | PrB-RTG R-F-S-M-O-D issue 3 of 28.12.2022

Reference standards (11)

PB-PEM-BHP issue 4 of 30.10.2018
PN-T-06580-3:2002 Method adapted to the regulated area
Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 151–180
Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 91–150
Principles and Methods of Assessing the Working Environment 2017, No. 2 (92), pp. 89–131
PrB-RTG R-F-S-M-O-D issue 3 of 28.12.2022
Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630)
Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630)
Annex 1 to the Regulation of the Minister of Health of 12 December 2022 (Journal of Laws 2022 item 2759)
Annexes 1 and 2 to the Regulation of the Minister of Health of 12 December 2022 (Journal of Laws 2022 item 2759)
Annex 2 to the Regulation of the Minister of Health of 12 December 2022 (Journal of Laws 2022 item 2759)

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/PL/AB%20365