🇵🇱 OŚRODEK BADAŃ I ANALIZ PP PL
Environment
OŚRODEK BADAŃ I ANALIZ PP is a laboratory accredited by PCA under number AB 286 (Kraków, Poland). Its accreditation scope covers 60 test methods in the following areas: Environment. Test objects include: Workplace environment - non-laser optical radiation, Environment – electromagnetic field in the vicinity of radiocommuni…, Workplace environment - noise, Environment – electromagnetic field in the vicinity of power instal…. Most frequently used techniques: Direct measurement method, Direct measurement, Direct measurement method (method A).
At a glance
- Accreditation number: PCA AB 286
- Methods in scope: 60
- Types of test objects: 25
- Techniques used: 9
- City: Kraków, Poland
- Accreditation number
- AB 286
- Accreditation body
- PCA
- Address
- Spółka z ograniczoną odpowiedzialnością, ul. Profesora Michała Bobrzyńskiego 23A lok.U2, 30-348 Kraków
- City
- Kraków, Poland
What this laboratory tests (25)
- Workplace environment - non-laser optical radiation — 11 methods
- Environment – electromagnetic field in the vicinity of radiocommunication installations: broadband measurements — 4 methods
- Workplace environment - noise — 4 methods
- Environment – electromagnetic field in the vicinity of power installations — 3 methods
- General environment – noise from high-voltage power lines — 3 methods
- Workplace environment - electromagnetic field from power systems and AC electrical supply installations in the power industry — 3 methods
- Workplace environment - electromagnetic field from transmitting devices of radiocommunication systems (broadcasting and radiocommunication systems - radio, television, mobile telephony base stations, etc.) — 3 methods
- Workplace environment - electromagnetic field in the workspace from magnetotherapy devices — 3 methods
- Workplace environment − electromagnetic field — 3 methods
- Workplace environment − hand-arm vibration — 3 methods
- Workplace environment − whole-body vibration — 3 methods
- Environment – electromagnetic field in the vicinity of radiocommunication installations: - selective measurements — 2 methods
- General environment - noise from installations, equipment and industrial plants — 2 methods
- Workstations equipped with devices emitting laser radiation — 2 methods
- Dental equipment – panoramic radiography and digital cephalometry units — 1 method
- and 10 more
Analytical techniques used (9)
- Direct measurement method — 22 methods
- Direct measurement — 2 methods
- Direct measurement method (method A) — 2 methods
- Direct measurement method (method D) — 1 method
- Direct measurement method (method M) — 1 method
- Direct measurement method (method O) — 1 method
- Direct measurement method (method R) — 1 method
- Direct measurement method (method U) — 1 method
- Direct measurement method (method X) — 1 method
Laboratory sections (3)
- OCCUPATIONAL HYGIENE LABORATORY (LB-6) — 28 methods
- ELECTROMAGNETIC FIELD LABORATORY (LB-1) — 21 methods
- RADIOLOGY LABORATORY (LB-5) — 11 methods
Laboratory locations
- OŚRODEK BADAŃ I ANALIZ PP (main site) — ul. Profesora Michała Bobrzyńskiego 23A lok.U2, 30-348 Kraków
- ELECTROMAGNETIC FIELD LABORATORY (LB-1) — ul. Profesora Michała Bobrzyńskiego 23A lok.U2, 30-348 Kraków
- OCCUPATIONAL HYGIENE LABORATORY (LB-6) — ul. Profesora Michała Bobrzyńskiego 23A lok.U2, 30-348 Kraków
- RADIOLOGY LABORATORY (LB-5) — ul. Profesora Michała Bobrzyńskiego 23A lok.U2, 30-348 Kraków
Certificate information
- Issue date
- 17.09.2026
- Issue no.
- 34
Accreditation scope — test methods (60)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| ELECTROMAGNETIC FIELD LABORATORY (LB-1) | |||||
| 1 | Workplace environment - electromagnetic field from power systems and AC electrical supply installations in the power industry | Electric field strength: - in the 50 Hz frequency range (100 - 50 000) V/m Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (consolidated text: Journal of Laws of 2018, item 331). |
Direct measurement method | Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 91–150 | |
| 2 | Workplace environment - electromagnetic field from power systems and AC electrical supply installations in the power industry | Magnetic flux density 50 Hz Range (0,05 - 19 000) µT Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (consolidated text: Journal of Laws of 2018, item 331). |
Direct measurement method | Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 91–150 | |
| 3 | Workplace environment - electromagnetic field from power systems and AC electrical supply installations in the power industry | Magnetic field strength (calculated). Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (consolidated text: Journal of Laws of 2018, item 331). |
Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 91–150 | ||
| 4 | Workplace environment - electromagnetic field in the workspace from magnetotherapy devices | Electric field strength in the frequency range from 100 Hz to 1000 Hz Range (0,9 - 49000) V/m Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (consolidated text: Journal of Laws of 2018, item 331). |
Direct measurement method | Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 151–180 | |
| 5 | Workplace environment - electromagnetic field in the workspace from magnetotherapy devices | Magnetic flux density in the frequency range from 10 to 1000 Hz Range (0,04 - 19 000) µT Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (consolidated text: Journal of Laws of 2018, item 331). |
Direct measurement method | Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 151–180 | |
| 6 | Workplace environment - electromagnetic field in the workspace from magnetotherapy devices | Magnetic field strength in the frequency range from 10 to 1000 Hz (calculated) Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (consolidated text: Journal of Laws of 2018, item 331). |
Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 151–180 | ||
| 7 | Workplace environment - electromagnetic field from transmitting devices of radiocommunication systems (broadcasting and radiocommunication systems - radio, television, mobile telephony base stations, etc.) | Electric field strength: - in the frequency range from 100 kHz to 3 GHz (0,5 - 1250) V/m from 80 MHz to 90 GHz (0,5 - 300) V/m Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (consolidated text: Journal of Laws of 2018, item 331). |
Direct measurement method | Principles and Methods of Assessing the Working Environment 2017, No. 2 (92), pp. 89–131 | |
| 8 | Workplace environment - electromagnetic field from transmitting devices of radiocommunication systems (broadcasting and radiocommunication systems - radio, television, mobile telephony base stations, etc.) | Magnetic field strength - in the frequency range from 300 kHz to 1 GHz (0,01 - 190) A/m Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (consolidated text: Journal of Laws of 2018, item 331). |
Direct measurement method | Principles and Methods of Assessing the Working Environment 2017, No. 2 (92), pp. 89–131 | |
| 9 | Workplace environment - electromagnetic field from transmitting devices of radiocommunication systems (broadcasting and radiocommunication systems - radio, television, mobile telephony base stations, etc.) | Magnetic field strength - in the frequency range from 800 MHz to 90 GHz (calculated) Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (consolidated text: Journal of Laws of 2018, item 331). |
Principles and Methods of Assessing the Working Environment 2017, No. 2 (92), pp. 89–131 | ||
| 10 | Workplace environment − electromagnetic field | Electric field strength in the frequency band: from 5 Hz to 600 kHz (0,5 - 30 000) V/m from 100 kHz to 3 GHz (0,5 - 1250) V/m from 80 MHz to 90 GHz (0,5 - 300) V/m Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (consolidated text: Journal of Laws of 2018, item 331). |
Direct measurement method | PN-T-06580-3:2002 Method adapted to the regulated area | |
| 11 | Workplace environment − electromagnetic field | Magnetic field strength in the frequency band from 0 Hz (0,1 - 900) mT from 10 Hz to 600 Hz (0,05 - 19000) µT from 300 kHz to 1 GHz (0,01 - 12) A/m Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (consolidated text: Journal of Laws of 2018, item 331). |
Direct measurement method | PN-T-06580-3:2002 Method adapted to the regulated area | |
| 12 | Workplace environment − electromagnetic field | Magnetic field strength in the frequency band: from 800 MHz to 90 GHz (calculated) Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (consolidated text: Journal of Laws of 2018, item 331). |
PN-T-06580-3:2002 Method adapted to the regulated area | ||
| 13 | Environment – electromagnetic field in the vicinity of power installations | Electric field strength: - in the frequency range from 50 Hz (100 – 50 000) V/m Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Direct measurement method | Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630) | |
| 14 | Environment – electromagnetic field in the vicinity of power installations | Magnetic flux density - in the 50 Hz frequency range (0,05 - 19 000) µT Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Direct measurement method | Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630) | |
| 15 | Environment – electromagnetic field in the vicinity of power installations | Magnetic field strength (calculated). Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630) | ||
| 16 | Environment – electromagnetic field in the vicinity of radiocommunication installations: broadband measurements | Electric field strength: - in the frequency range from 100 kHz to 3 GHz (0,5 - 1250) V/m - in the frequency range from 80 MHz to 90 GHz (0,5 - 300) V/m Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Direct measurement method | Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630) | |
| 17 | Environment – electromagnetic field in the vicinity of radiocommunication installations: broadband measurements | Magnetic field strength: - in the frequency range from 300 kHz to 1 GHz (0,01 - 12,0) A/m Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Direct measurement method | Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630) | |
| 18 | Environment – electromagnetic field in the vicinity of radiocommunication installations: broadband measurements | Magnetic field strength in the frequency band: from 300 MHz to 90 GHz (calculated) Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630) | ||
| 19 | Environment – electromagnetic field in the vicinity of radiocommunication installations: broadband measurements | Power density in the frequency band: from 300 MHz – 3 GHz (calculated) Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630) | ||
| 20 | Environment – electromagnetic field in the vicinity of radiocommunication installations: - selective measurements | Electric field strength: - in the frequency range from 420 MHz to 6 GHz (0,01 - 200) V/m Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Direct measurement method | Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630) | |
| 21 | Environment – electromagnetic field in the vicinity of radiocommunication installations: - selective measurements | Magnetic field strength in the frequency band: from 420 MHz to 6 GHz (calculated) Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630) | ||
| OCCUPATIONAL HYGIENE LABORATORY (LB-6) | |||||
| 22 | Workplace environment - noise | A-weighted equivalent sound pressure level Range (43 - 115) dB |
Direct measurement method | PN-N-01307:1994 | PN-EN ISO 9612:2011 excluding the method covering strategies 2 and 3 – cl. 10 and 11 | |
| 23 | Workplace environment - noise | Maximum A-weighted sound pressure level Range (43 - 115) dB |
Direct measurement method | PN-N-01307:1994 | PN-EN ISO 9612:2011 excluding the method covering strategies 2 and 3 – cl. 10 and 11 | |
| 24 | Workplace environment - noise | C-weighted peak sound pressure level Range (43 - 137) dB |
Direct measurement method | PN-N-01307:1994 | PN-EN ISO 9612:2011 excluding the method covering strategies 2 and 3 – cl. 10 and 11 | |
| 25 | Workplace environment - noise | Noise exposure level normalized to: - an 8-hour working day - an average working week (calculated) | PN-N-01307:1994 | PN-EN ISO 9612:2011 excluding the method covering strategies 2 and 3 – cl. 10 and 11 | ||
| 26 | General environment - noise from installations, equipment and industrial plants | A-weighted equivalent sound pressure level Range (24 - 137) dB |
Direct measurement method | Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023 item 1706) – excluding cl. E.II.1 and F | |
| 27 | General environment - noise from installations, equipment and industrial plants | A-weighted equivalent sound level for the reference time T expressed by the index LAeqD and LAeqN (calculated) | Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023 item 1706) – excluding cl. E.II.1 and F | ||
| 28 | Workplace environment − whole-body vibration | Frequency-weighted r.m.s. vibration acceleration Range (0,02 - 17,8) m/s2 |
Direct measurement method | PN-EN 14253+A1:2011 | |
| 29 | Workplace environment − whole-body vibration | Daily exposure, expressed as the 8-hour energy-equivalent effective frequency-weighted vibration acceleration, dominant among the vibration accelerations determined for the three directional components, taking into account the appropriate coefficients (1.4awx, 1.4awy , awz) | PN-EN 14253+A1:2011 | ||
| 30 | Workplace environment − whole-body vibration | Exposure lasting 30 minutes or less, expressed as the effective frequency-weighted vibration acceleration, dominant among the vibration accelerations determined for the three directional components, taking into account the appropriate coefficients (1.4awx, 1.4awy , awz ) (calculated) | PN-EN 14253+A1:2011 | ||
| 31 | Workplace environment − hand-arm vibration | Frequency-weighted RMS values of vibration acceleration Range (0,06 - 100) m/s2 |
Direct measurement method | PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11 | |
| 32 | Workplace environment − hand-arm vibration | Daily exposure, expressed as the 8-hour energy-equivalent vector sum of the effective frequency-weighted vibration accelerations determined for the three directional components (awx, awy, awz) | PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11 | ||
| 33 | Workplace environment − hand-arm vibration | Exposure lasting 30 minutes or less, expressed as the vector sum of the effective frequency-weighted vibration accelerations determined for the three directional components (awx, awy, awz) (calculated) | PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11 | ||
| 34 | General environment – noise from high-voltage power lines | A-weighted equivalent sound pressure level Range (24,0 – 137,0) dB |
Direct measurement method | Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023, item 1706) – excluding cl. E.II.1 and F | PN-N 01339:2000 | |
| 35 | General environment – noise from high-voltage power lines | A-weighted equivalent sound level for the reference time T expressed by the indicators LAeqD and L AAeqN | Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023, item 1706) – excluding cl. E.II.1 and F | PN-N 01339:2000 | ||
| 36 | General environment – noise from high-voltage power lines | Long-term A-weighted equivalent sound level expressed by the indicators LAeq,LTd and LAeq,LTn (calculated) | Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023, item 1706) – excluding cl. E.II.1 and F | PN-N 01339:2000 | ||
| 37 | Workplace environment - non-laser optical radiation | Effective irradiance UVA, UVB and UVC in the spectral range 180 - 400 nm Measuring range 8*10 -4 - 10 [W/m2] |
Direct measurement method (method A) | PN-EN 14255-1:2010 | |
| 38 | Workplace environment - non-laser optical radiation | Effective radiant exposure UVA, UVB and UVC in the spectral range 180 - 400 nm (calculated) | PN-EN 14255-1:2010 | ||
| 39 | Workplace environment - non-laser optical radiation | Irradiance for UVA in the spectral range 315 - 390 nm Measuring range 2*10 -4 - 2*103 [W/m2] |
Direct measurement method (method M) | PN-EN 14255-1:2010 | |
| 40 | Workplace environment - non-laser optical radiation | Radiant exposure for UVA in the spectral range 315 - 390 nm (calculated) | PN-EN 14255-1:2010 | ||
| 41 | Workplace environment - non-laser optical radiation | Effective irradiance in the spectral range 305 - 700 nm Measuring range 2*10-4 - 3*103 [W/m2] |
Direct measurement method (method O) | PN-EN 14255-2:2010 | |
| 42 | Workplace environment - non-laser optical radiation | Irradiance in the spectral range 770 - 3000 nm Measuring range 9*10-1 - 4*103 [W/m2] |
Direct measurement method (method R) | PN-EN 14255-2:2010 | |
| 43 | Workplace environment - non-laser optical radiation | Effective radiance VIS in the spectral range 305 - 700 nm Measuring range 1,4*10-3 - 2,78*104 [W/m2*sr] |
Direct measurement method (method D) | PN-EN 14255-2:2010 | |
| 44 | Workplace environment - non-laser optical radiation | Effective radiance VIS and IRA in the spectral range 380 - 1400 nm Measuring range 2*10-3 - 2*106 [W/m2*sr] |
Direct measurement method (method A) | PN-EN 14255-2:2010 | |
| 45 | Workplace environment - non-laser optical radiation | Effective radiance IRA in the spectral range 780 - 1400 nm Measuring range 2,75*10-3 - 2,75*106 [W/m2*sr] |
Direct measurement method (method U) | PN-EN 14255-2:2010 | |
| 46 | Workplace environment - non-laser optical radiation | VIS, IRA and IRB irradiance in the spectral range 380 - 3000 nm Measuring range 9*10-1 - 4*103 [W/m2] |
Direct measurement method (method X) | PN-EN 14255-2:2010 | |
| 47 | Workplace environment - non-laser optical radiation | Radiant exposure for VIS, IRA and IRB in the spectral range 380 - 3000 nm (calculated) | PN-EN 14255-2:2010 | ||
| 48 | Workstations equipped with devices emitting laser radiation | Power of laser radiation generated by laser devices Laser radiation wavelength range 0,19 - 10,6 [μm] Laser radiation power range 100 µW - 700 W |
Direct measurement method | PN-EN ISO 11554:2010 | PN-EN ISO 11554:2018-01 | |
| 49 | Workstations equipped with devices emitting laser radiation | Laser radiation pulse energy: Measuring range: − 20 nJ – 20 µJ in the radiation wavelength range λ = (0,19 – 1,1) µm, 20 nJ – 20 µJ − 8 µJ – 10 J in the radiation wavelength range λ = (0,15 – 3,0) µm, 8 µJ – 10 J − 1 mJ – 30 J in the radiation wavelength range λ = (0,19 – 10,6) µm, 1 mJ – 30 J − 120 mJ – 300 J in the radiation wavelength range λ = (0,19 – 10,6) µm, 120 mJ – 300 J |
Direct measurement method | PN-EN ISO 11554:2010 | PN-EN ISO 11554:2018-01 | |
| RADIOLOGY LABORATORY (LB-5) | |||||
| 50 | Equipment used in general analogue radiography | Specialist tests | Annexes 1 and 2 to the Regulation of the Minister of Health of 12 December 2022 (Journal of Laws 2022 item 2759) | PB/J/1.8 of 18.05.2018 | ||
| 51 | Equipment used in general digital radiography | Specialist tests | Annexes 1 and 2 to the Regulation of the Minister of Health of 12 December 2022 (Journal of Laws 2022 item 2759) | PB/J/1.8 of 18.05.2018 | ||
| 52 | Dental equipment – panoramic radiography and digital cephalometry units | Specialist tests | Annexes 1 and 2 to the Regulation of the Minister of Health of 12 December 2022 (Journal of Laws 2022 item 2759) | PB/J/3.6 of 18.05.2018 | ||
| 53 | Equipment used in dentistry – units for intra oral radiography | Specialist tests | Annex 1 to the Regulation of the Minister of Health of 12 December 2022 (Journal of Laws 2022 item 2759) | PB/J/2.7 of 18.05.2018 | ||
| 54 | Equipment used in dental cone beam computed tomography | Specialist tests | Annex 1 to the Regulation of the Minister of Health of 12 December 2022 (Journal of Laws 2022 item 2759) | PB/J/3.6 of 18.05.2018 | ||
| 55 | Equipment used in fluoroscopy and angiography | Specialist tests | Annex 1 to the Regulation of the Minister of Health of 12 December 2022 (Journal of Laws 2022 item 2759) | PB/J/5.9 of 17.03.2025 | ||
| 56 | Equipment used in digital mammography | Specialist tests | Annexes 1 and 2 to the Regulation of the Minister of Health of 12 December 2022 (Journal of Laws 2022 item 2759) | PB/J/4.8 of 26.06.2023 | ||
| 57 | Equipment used in computed tomography | Specialist tests | Annex 1 to the Regulation of the Minister of Health of 12 December 2022 (Journal of Laws 2022 item 2759) | PB/J/8.3 of 18.05.2018 | ||
| 58 | Monitors used for the display of medical images | Specialist tests | Annex 2 to the Regulation of the Minister of Health of 12 December 2022 (Journal of Laws 2022 item 2759) | PB/J/9.4 of 18.05.2018 | ||
| 59 | Workplace environment – ionising radiation | Dose rate in the vicinity of the X-ray apparatus Range 10 nSv/h – 100 mSv/h |
Direct measurement | PB/J/6.4 of 20.05.2021 | |
| 60 | General environment – ionising radiation | Dose rate in the vicinity of the X-ray apparatus Range 10 nSv/h – 100 mSv/h |
Direct measurement | PB/J/6.4 of 20.05.2021 | |
Reference standards (29)
PB/J/1.8 of 18.05.2018
PB/J/2.7 of 18.05.2018
PB/J/3.6 of 18.05.2018
PB/J/4.8 of 26.06.2023
PB/J/5.9 of 17.03.2025
PB/J/6.4 of 20.05.2021
PB/J/8.3 of 18.05.2018
PB/J/9.4 of 18.05.2018
PN-EN 14253+A1:2011
PN-EN 14255-1:2010
PN-EN 14255-2:2010
PN-EN ISO 11554:2010
PN-EN ISO 11554:2018-01
PN-EN ISO 5349-1:2004
PN-EN ISO 5349-2:2004
PN-EN ISO 5349-2:2004/A1:2015-11
PN-EN ISO 9612:2011 excluding the method covering strategies 2 and 3 – cl. 10 and 11
PN-N 01339:2000
PN-N-01307:1994
PN-T-06580-3:2002 Method adapted to the regulated area
Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 151–180
Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 91–150
Principles and Methods of Assessing the Working Environment 2017, No. 2 (92), pp. 89–131
Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630)
Annex 1 to the Regulation of the Minister of Health of 12 December 2022 (Journal of Laws 2022 item 2759)
Annexes 1 and 2 to the Regulation of the Minister of Health of 12 December 2022 (Journal of Laws 2022 item 2759)
Annex 2 to the Regulation of the Minister of Health of 12 December 2022 (Journal of Laws 2022 item 2759)
Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023 item 1706) – excluding cl. E.II.1 and F
Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023, item 1706) – excluding cl. E.II.1 and F