🇵🇱 OŚRODEK BADAŃ I ANALIZ PP PL

PCA AB 286 • Kraków, Poland • 60 methods

Environment

OŚRODEK BADAŃ I ANALIZ PP is a laboratory accredited by PCA under number AB 286 (Kraków, Poland). Its accreditation scope covers 60 test methods in the following areas: Environment. Test objects include: Workplace environment - non-laser optical radiation, Environment – electromagnetic field in the vicinity of radiocommuni…, Workplace environment - noise, Environment – electromagnetic field in the vicinity of power instal…. Most frequently used techniques: Direct measurement method, Direct measurement, Direct measurement method (method A).

At a glance

  • Accreditation number: PCA AB 286
  • Methods in scope: 60
  • Types of test objects: 25
  • Techniques used: 9
  • City: Kraków, Poland
Accreditation number
AB 286
Accreditation body
PCA
Address
Spółka z ograniczoną odpowiedzialnością, ul. Profesora Michała Bobrzyńskiego 23A lok.U2, 30-348 Kraków
City
Kraków, Poland

What this laboratory tests (25)

Analytical techniques used (9)

Laboratory sections (3)

Laboratory locations

Certificate information

Issue date
17.09.2026
Issue no.
34

Accreditation scope — test methods (60)

No. Test object Methodology / Parameters Technique Reference document
ELECTROMAGNETIC FIELD LABORATORY (LB-1)
1 Workplace environment - electromagnetic field from power systems and AC electrical supply installations in the power industry Electric field strength:
- in the 50 Hz frequency range (100 - 50 000) V/m
Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (consolidated text: Journal of Laws of 2018, item 331).
Direct measurement method Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 91–150
2 Workplace environment - electromagnetic field from power systems and AC electrical supply installations in the power industry Magnetic flux density 50 Hz
Range (0,05 - 19 000) µT
Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (consolidated text: Journal of Laws of 2018, item 331).
Direct measurement method Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 91–150
3 Workplace environment - electromagnetic field from power systems and AC electrical supply installations in the power industry Magnetic field strength (calculated).
Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (consolidated text: Journal of Laws of 2018, item 331).
Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 91–150
4 Workplace environment - electromagnetic field in the workspace from magnetotherapy devices Electric field strength in the frequency range from 100 Hz to 1000 Hz
Range (0,9 - 49000) V/m
Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (consolidated text: Journal of Laws of 2018, item 331).
Direct measurement method Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 151–180
5 Workplace environment - electromagnetic field in the workspace from magnetotherapy devices Magnetic flux density in the frequency range from 10 to 1000 Hz
Range (0,04 - 19 000) µT
Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (consolidated text: Journal of Laws of 2018, item 331).
Direct measurement method Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 151–180
6 Workplace environment - electromagnetic field in the workspace from magnetotherapy devices Magnetic field strength in the frequency range from 10 to 1000 Hz (calculated)
Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (consolidated text: Journal of Laws of 2018, item 331).
Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 151–180
7 Workplace environment - electromagnetic field from transmitting devices of radiocommunication systems (broadcasting and radiocommunication systems - radio, television, mobile telephony base stations, etc.) Electric field strength:
- in the frequency range from 100 kHz to 3 GHz (0,5 - 1250) V/m from 80 MHz to 90 GHz (0,5 - 300) V/m
Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (consolidated text: Journal of Laws of 2018, item 331).
Direct measurement method Principles and Methods of Assessing the Working Environment 2017, No. 2 (92), pp. 89–131
8 Workplace environment - electromagnetic field from transmitting devices of radiocommunication systems (broadcasting and radiocommunication systems - radio, television, mobile telephony base stations, etc.) Magnetic field strength
- in the frequency range from 300 kHz to 1 GHz (0,01 - 190) A/m
Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (consolidated text: Journal of Laws of 2018, item 331).
Direct measurement method Principles and Methods of Assessing the Working Environment 2017, No. 2 (92), pp. 89–131
9 Workplace environment - electromagnetic field from transmitting devices of radiocommunication systems (broadcasting and radiocommunication systems - radio, television, mobile telephony base stations, etc.) Magnetic field strength - in the frequency range from 800 MHz to 90 GHz (calculated)
Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (consolidated text: Journal of Laws of 2018, item 331).
Principles and Methods of Assessing the Working Environment 2017, No. 2 (92), pp. 89–131
10 Workplace environment − electromagnetic field Electric field strength in the frequency band:
from 5 Hz to 600 kHz (0,5 - 30 000) V/m from 100 kHz to 3 GHz (0,5 - 1250) V/m from 80 MHz to 90 GHz (0,5 - 300) V/m
Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (consolidated text: Journal of Laws of 2018, item 331).
Direct measurement method PN-T-06580-3:2002 Method adapted to the regulated area
11 Workplace environment − electromagnetic field Magnetic field strength in the frequency band
from 0 Hz (0,1 - 900) mT from 10 Hz to 600 Hz (0,05 - 19000) µT from 300 kHz to 1 GHz (0,01 - 12) A/m
Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (consolidated text: Journal of Laws of 2018, item 331).
Direct measurement method PN-T-06580-3:2002 Method adapted to the regulated area
12 Workplace environment − electromagnetic field Magnetic field strength in the frequency band: from 800 MHz to 90 GHz (calculated)
Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (consolidated text: Journal of Laws of 2018, item 331).
PN-T-06580-3:2002 Method adapted to the regulated area
13 Environment – electromagnetic field in the vicinity of power installations Electric field strength:
- in the frequency range from 50 Hz (100 – 50 000) V/m
Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Direct measurement method Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630)
14 Environment – electromagnetic field in the vicinity of power installations Magnetic flux density
- in the 50 Hz frequency range (0,05 - 19 000) µT
Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Direct measurement method Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630)
15 Environment – electromagnetic field in the vicinity of power installations Magnetic field strength (calculated).
Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630)
16 Environment – electromagnetic field in the vicinity of radiocommunication installations: broadband measurements Electric field strength:
- in the frequency range from 100 kHz to 3 GHz (0,5 - 1250) V/m - in the frequency range from 80 MHz to 90 GHz (0,5 - 300) V/m
Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Direct measurement method Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630)
17 Environment – electromagnetic field in the vicinity of radiocommunication installations: broadband measurements Magnetic field strength:
- in the frequency range from 300 kHz to 1 GHz (0,01 - 12,0) A/m
Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Direct measurement method Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630)
18 Environment – electromagnetic field in the vicinity of radiocommunication installations: broadband measurements Magnetic field strength in the frequency band: from 300 MHz to 90 GHz (calculated)
Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630)
19 Environment – electromagnetic field in the vicinity of radiocommunication installations: broadband measurements Power density in the frequency band: from 300 MHz – 3 GHz (calculated)
Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630)
20 Environment – electromagnetic field in the vicinity of radiocommunication installations: - selective measurements Electric field strength:
- in the frequency range from 420 MHz to 6 GHz (0,01 - 200) V/m
Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Direct measurement method Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630)
21 Environment – electromagnetic field in the vicinity of radiocommunication installations: - selective measurements Magnetic field strength in the frequency band: from 420 MHz to 6 GHz (calculated)
Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630)
OCCUPATIONAL HYGIENE LABORATORY (LB-6)
22 Workplace environment - noise A-weighted equivalent sound pressure level
Range (43 - 115) dB
Direct measurement method PN-N-01307:1994 | PN-EN ISO 9612:2011 excluding the method covering strategies 2 and 3 – cl. 10 and 11
23 Workplace environment - noise Maximum A-weighted sound pressure level
Range (43 - 115) dB
Direct measurement method PN-N-01307:1994 | PN-EN ISO 9612:2011 excluding the method covering strategies 2 and 3 – cl. 10 and 11
24 Workplace environment - noise C-weighted peak sound pressure level
Range (43 - 137) dB
Direct measurement method PN-N-01307:1994 | PN-EN ISO 9612:2011 excluding the method covering strategies 2 and 3 – cl. 10 and 11
25 Workplace environment - noise Noise exposure level normalized to: - an 8-hour working day - an average working week (calculated) PN-N-01307:1994 | PN-EN ISO 9612:2011 excluding the method covering strategies 2 and 3 – cl. 10 and 11
26 General environment - noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level
Range (24 - 137) dB
Direct measurement method Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023 item 1706) – excluding cl. E.II.1 and F
27 General environment - noise from installations, equipment and industrial plants A-weighted equivalent sound level for the reference time T expressed by the index LAeqD and LAeqN (calculated) Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023 item 1706) – excluding cl. E.II.1 and F
28 Workplace environment − whole-body vibration Frequency-weighted r.m.s. vibration acceleration
Range (0,02 - 17,8) m/s2
Direct measurement method PN-EN 14253+A1:2011
29 Workplace environment − whole-body vibration Daily exposure, expressed as the 8-hour energy-equivalent effective frequency-weighted vibration acceleration, dominant among the vibration accelerations determined for the three directional components, taking into account the appropriate coefficients (1.4awx, 1.4awy , awz) PN-EN 14253+A1:2011
30 Workplace environment − whole-body vibration Exposure lasting 30 minutes or less, expressed as the effective frequency-weighted vibration acceleration, dominant among the vibration accelerations determined for the three directional components, taking into account the appropriate coefficients (1.4awx, 1.4awy , awz ) (calculated) PN-EN 14253+A1:2011
31 Workplace environment − hand-arm vibration Frequency-weighted RMS values of vibration acceleration
Range (0,06 - 100) m/s2
Direct measurement method PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11
32 Workplace environment − hand-arm vibration Daily exposure, expressed as the 8-hour energy-equivalent vector sum of the effective frequency-weighted vibration accelerations determined for the three directional components (awx, awy, awz) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11
33 Workplace environment − hand-arm vibration Exposure lasting 30 minutes or less, expressed as the vector sum of the effective frequency-weighted vibration accelerations determined for the three directional components (awx, awy, awz) (calculated) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11
34 General environment – noise from high-voltage power lines A-weighted equivalent sound pressure level
Range (24,0 – 137,0) dB
Direct measurement method Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023, item 1706) – excluding cl. E.II.1 and F | PN-N 01339:2000
35 General environment – noise from high-voltage power lines A-weighted equivalent sound level for the reference time T expressed by the indicators LAeqD and L AAeqN Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023, item 1706) – excluding cl. E.II.1 and F | PN-N 01339:2000
36 General environment – noise from high-voltage power lines Long-term A-weighted equivalent sound level expressed by the indicators LAeq,LTd and LAeq,LTn (calculated) Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023, item 1706) – excluding cl. E.II.1 and F | PN-N 01339:2000
37 Workplace environment - non-laser optical radiation Effective irradiance UVA, UVB and UVC in the spectral range 180 - 400 nm
Measuring range 8*10 -4 - 10 [W/m2]
Direct measurement method (method A) PN-EN 14255-1:2010
38 Workplace environment - non-laser optical radiation Effective radiant exposure UVA, UVB and UVC in the spectral range 180 - 400 nm (calculated) PN-EN 14255-1:2010
39 Workplace environment - non-laser optical radiation Irradiance for UVA in the spectral range 315 - 390 nm
Measuring range 2*10 -4 - 2*103 [W/m2]
Direct measurement method (method M) PN-EN 14255-1:2010
40 Workplace environment - non-laser optical radiation Radiant exposure for UVA in the spectral range 315 - 390 nm (calculated) PN-EN 14255-1:2010
41 Workplace environment - non-laser optical radiation Effective irradiance in the spectral range 305 - 700 nm
Measuring range 2*10-4 - 3*103 [W/m2]
Direct measurement method (method O) PN-EN 14255-2:2010
42 Workplace environment - non-laser optical radiation Irradiance in the spectral range 770 - 3000 nm
Measuring range 9*10-1 - 4*103 [W/m2]
Direct measurement method (method R) PN-EN 14255-2:2010
43 Workplace environment - non-laser optical radiation Effective radiance VIS in the spectral range 305 - 700 nm
Measuring range 1,4*10-3 - 2,78*104 [W/m2*sr]
Direct measurement method (method D) PN-EN 14255-2:2010
44 Workplace environment - non-laser optical radiation Effective radiance VIS and IRA in the spectral range 380 - 1400 nm
Measuring range 2*10-3 - 2*106 [W/m2*sr]
Direct measurement method (method A) PN-EN 14255-2:2010
45 Workplace environment - non-laser optical radiation Effective radiance IRA in the spectral range 780 - 1400 nm
Measuring range 2,75*10-3 - 2,75*106 [W/m2*sr]
Direct measurement method (method U) PN-EN 14255-2:2010
46 Workplace environment - non-laser optical radiation VIS, IRA and IRB irradiance in the spectral range 380 - 3000 nm
Measuring range 9*10-1 - 4*103 [W/m2]
Direct measurement method (method X) PN-EN 14255-2:2010
47 Workplace environment - non-laser optical radiation Radiant exposure for VIS, IRA and IRB in the spectral range 380 - 3000 nm (calculated) PN-EN 14255-2:2010
48 Workstations equipped with devices emitting laser radiation Power of laser radiation generated by laser devices
Laser radiation wavelength range 0,19 - 10,6 [μm] Laser radiation power range 100 µW - 700 W
Direct measurement method PN-EN ISO 11554:2010 | PN-EN ISO 11554:2018-01
49 Workstations equipped with devices emitting laser radiation Laser radiation pulse energy:
Measuring range: − 20 nJ – 20 µJ in the radiation wavelength range λ = (0,19 – 1,1) µm, 20 nJ – 20 µJ − 8 µJ – 10 J in the radiation wavelength range λ = (0,15 – 3,0) µm, 8 µJ – 10 J − 1 mJ – 30 J in the radiation wavelength range λ = (0,19 – 10,6) µm, 1 mJ – 30 J − 120 mJ – 300 J in the radiation wavelength range λ = (0,19 – 10,6) µm, 120 mJ – 300 J
Direct measurement method PN-EN ISO 11554:2010 | PN-EN ISO 11554:2018-01
RADIOLOGY LABORATORY (LB-5)
50 Equipment used in general analogue radiography Specialist tests Annexes 1 and 2 to the Regulation of the Minister of Health of 12 December 2022 (Journal of Laws 2022 item 2759) | PB/J/1.8 of 18.05.2018
51 Equipment used in general digital radiography Specialist tests Annexes 1 and 2 to the Regulation of the Minister of Health of 12 December 2022 (Journal of Laws 2022 item 2759) | PB/J/1.8 of 18.05.2018
52 Dental equipment – panoramic radiography and digital cephalometry units Specialist tests Annexes 1 and 2 to the Regulation of the Minister of Health of 12 December 2022 (Journal of Laws 2022 item 2759) | PB/J/3.6 of 18.05.2018
53 Equipment used in dentistry – units for intra oral radiography Specialist tests Annex 1 to the Regulation of the Minister of Health of 12 December 2022 (Journal of Laws 2022 item 2759) | PB/J/2.7 of 18.05.2018
54 Equipment used in dental cone beam computed tomography Specialist tests Annex 1 to the Regulation of the Minister of Health of 12 December 2022 (Journal of Laws 2022 item 2759) | PB/J/3.6 of 18.05.2018
55 Equipment used in fluoroscopy and angiography Specialist tests Annex 1 to the Regulation of the Minister of Health of 12 December 2022 (Journal of Laws 2022 item 2759) | PB/J/5.9 of 17.03.2025
56 Equipment used in digital mammography Specialist tests Annexes 1 and 2 to the Regulation of the Minister of Health of 12 December 2022 (Journal of Laws 2022 item 2759) | PB/J/4.8 of 26.06.2023
57 Equipment used in computed tomography Specialist tests Annex 1 to the Regulation of the Minister of Health of 12 December 2022 (Journal of Laws 2022 item 2759) | PB/J/8.3 of 18.05.2018
58 Monitors used for the display of medical images Specialist tests Annex 2 to the Regulation of the Minister of Health of 12 December 2022 (Journal of Laws 2022 item 2759) | PB/J/9.4 of 18.05.2018
59 Workplace environment – ionising radiation Dose rate in the vicinity of the X-ray apparatus
Range 10 nSv/h – 100 mSv/h
Direct measurement PB/J/6.4 of 20.05.2021
60 General environment – ionising radiation Dose rate in the vicinity of the X-ray apparatus
Range 10 nSv/h – 100 mSv/h
Direct measurement PB/J/6.4 of 20.05.2021

Reference standards (29)

PB/J/1.8 of 18.05.2018
PB/J/2.7 of 18.05.2018
PB/J/3.6 of 18.05.2018
PB/J/4.8 of 26.06.2023
PB/J/5.9 of 17.03.2025
PB/J/6.4 of 20.05.2021
PB/J/8.3 of 18.05.2018
PB/J/9.4 of 18.05.2018
PN-EN 14253+A1:2011
PN-EN 14255-1:2010
PN-EN 14255-2:2010
PN-EN ISO 11554:2010
PN-EN ISO 11554:2018-01
PN-EN ISO 5349-1:2004
PN-EN ISO 5349-2:2004
PN-EN ISO 5349-2:2004/A1:2015-11
PN-EN ISO 9612:2011 excluding the method covering strategies 2 and 3 – cl. 10 and 11
PN-N 01339:2000
PN-N-01307:1994
PN-T-06580-3:2002 Method adapted to the regulated area
Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 151–180
Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 91–150
Principles and Methods of Assessing the Working Environment 2017, No. 2 (92), pp. 89–131
Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630)
Annex 1 to the Regulation of the Minister of Health of 12 December 2022 (Journal of Laws 2022 item 2759)
Annexes 1 and 2 to the Regulation of the Minister of Health of 12 December 2022 (Journal of Laws 2022 item 2759)
Annex 2 to the Regulation of the Minister of Health of 12 December 2022 (Journal of Laws 2022 item 2759)
Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023 item 1706) – excluding cl. E.II.1 and F
Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023, item 1706) – excluding cl. E.II.1 and F

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/PL/AB%20286