🇵🇱 GŁÓWNY INSPEKTORAT OCHRONY ŚRODOWISKA PL

PCA AB 177 • Warszawa, Poland • 85 methods

Water & wastewaterMaterials & polymers

GŁÓWNY INSPEKTORAT OCHRONY ŚRODOWISKA is a laboratory accredited by PCA under number AB 177 (Warszawa, Poland). Its accreditation scope covers 85 test methods in the following areas: Water & wastewater, Materials & polymers. Test objects include: Water, wastewater, Water, Wastewater, Environment - electromagnetic field in the vicinity of radiocommuni…. Most frequently used techniques: Spectrophotometric method, Continuous flow analysis (CFA) with spectrophotometric detection, Titrimetric method.

At a glance

  • Accreditation number: PCA AB 177
  • Methods in scope: 85
  • Types of test objects: 5
  • Techniques used: 18
  • City: Warszawa, Poland
Accreditation number
AB 177
Accreditation body
PCA
Address
ul. Chmielna 132/134, 00-805 Warszawa, CENTRALNE LABORATORIUM BADAWCZE, ODDZIAŁ W SZCZECINIE, ul. Wały Chrobrego 4
City
Warszawa, Poland

What this laboratory tests (5)

Analytical techniques used (18)

Laboratory sections (3)

Laboratory locations

Certificate information

Issue date
06.05.2026
Issue no.
28

Accreditation scope — test methods (85)

No. Test object Methodology / Parameters Technique Reference document
Field Laboratory
1 Water Sampling for chemical and physical testing PN-ISO 5667-4:2017-10 | PN-EN ISO 5667-6:2016-12 excluding cl. 9.2 and 9.4 | PN-ISO 5667-9:2005 | PN-ISO 5667-11:2017-10 excluding cl. 5.2, 6.1.2, 6.2, 6.3
2 Water Temperature
Range (0 – 50,0) °C
PN-77/C-04584
3 Water Dissolved oxygen concentration
Range (0,5 – 20) mg/l O2
Optical method ISO 17289:2014
4 Water Dissolved oxygen concentration
Range (0,5 – 20) mg/l O2
Electrochemical method PN-EN ISO 5814:2013-04
5 Wastewater Sampling for chemical and physical testing Manual and automatic method PN-ISO 5667-10:2021-11
6 Wastewater Temperature
Range (0 – 50,0) °C
PN-77/C-04584
7 Water, wastewater Electrical conductivity
Range (10,0 – 13 000) µS/cm
Conductometric method PN-EN 27888:1999
8 Water, wastewater pH
Range 2,0 – 12,0
Potentiometric method PN-EN ISO 10523:2012
9 General environment - noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level
Range (24 – 135) dB
Direct measurement method Annex 7 to the Regulation of the Minister of Climate and Environment of 7 September 2021 (consolidated text Journal of Laws of 2023, item 1706) excluding cl. F
10 General environment - noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Annex 7 to the Regulation of the Minister of Climate and Environment of 7 September 2021 (consolidated text Journal of Laws of 2023, item 1706) excluding cl. F
11 Environment - electromagnetic field in the vicinity of radiocommunication installations: broadband measurements Electric field strength:
in the frequency range from 10 MHz to 60 GHz Range (0,5 – 300) V/m
Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Direct measurement method Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630)
12 Environment - electromagnetic field in the vicinity of radiocommunication installations: broadband measurements Magnetic field strength:
in the frequency range from 10 MHz to 60 GHz (calculated)
Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630)
Laboratory in Szczecin
13 Water Nitrite nitrogen concentration
Range (0,001 – 10,0) mg/l
Spectrophotometric method PN-EN 26777:1999
14 Water Nitrite concentration (calculated) PN-EN 26777:1999
15 Water Total nitrogen concentration
Range (0,25 – 100) mg/l
Continuous flow analysis (CFA) with spectrophotometric detection PN-EN ISO 11905-1:2001
16 Water Dissolved ion concentration
chlorides (1,0 – 1000) mg/l nitrates (0,50 – 300) mg/l sulfates (1,0 – 1000) mg/l fluorides (0,10 – 10) mg/l
Ion chromatography with conductometric detection (IC-CD) PN-EN ISO 10304-1:2009 | PN-EN ISO 10304-1:2009/AC:2012
17 Water Nitrate nitrogen concentration (calculated) PN-EN ISO 10304-1:2009 | PN-EN ISO 10304-1:2009/AC:2012
18 Water Dissolved ion concentration
potassium (0,50 – 100) mg/l sodium (1,0 – 500) mg/l magnesium (1,0 – 100) mg/l calcium (2,0 – 500) mg/l
Ion chromatography with conductometric detection (IC-CD) PN-EN ISO 14911:2002
19 Water Metal concentrations
barium (0,020 – 10) mg/l boron (0,100 – 10) mg/l
Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN ISO 11885:2009
20 Water Metal concentrations
arsenic (0,001 – 5) mg/l selenium (0,002 – 5) mg/l cadmium (0,000024 – 10) mg/l lead (0,00036 – 10) mg/l
Electrothermal atomization atomic absorption spectrometry (ETAAS) PN-EN ISO 15586:2005
21 Water Metal concentrations
cadmium (0,000024 – 10) mg/l lead (0,00036 – 10) mg/l
Inductively coupled plasma mass spectrometry (ICP-MS) PN-EN ISO 17294-2: 2024-4
22 Water Total phosphorus concentration
Range (0,01 – 50) mg/l
Spectrophotometric method PN-EN ISO 6878:2006 chapter 7 | PN-EN ISO 6878:2006/Ap1:2010 | PN-EN ISO 6878:2006/Ap2:2010
23 Wastewater Metal concentrations
cadmium (0,0001 – 10) mg/l lead (0,001 – 10) mg/l
Inductively coupled plasma mass spectrometry (ICP-MS) PN-EN ISO 17294-2: 2024-4
24 Wastewater Metal concentrations
cadmium (0,0001 – 10) mg/l lead (0,001 – 10) mg/l
Electrothermal atomization atomic absorption spectrometry (ETAAS) PN-EN ISO 15586:2005
25 Water, wastewater Phenol index
Range (0,0030 – 5,0) mg/l
Continuous flow analysis (CFA) with spectrophotometric detection PN-EN ISO 14402:2004 cl. 4
26 Water, wastewater Kjeldahl nitrogen concentration
Range (0,3 – 100) mg/l
Titrimetric method PN-EN 25663:2001
27 Water, wastewater Volatile organic compound (VOC) concentration
Trichloroethylene (1,0 – 100) µg/l Tetrachloroethylene (1,0 – 100) µg/l Trichloromethane ( 0,5 – 100) µg/l Benzene (1,0 – 100) µg/l Toluene (1,0 – 100) µg/l m,p-Xylene (2,0 – 200) µg/l o-Xylene (1,0 – 100) µg/l 1,2- Dichloroethane (1,0 – 100) µg/l Hexachlorobutadiene (0,18 – 100) µg/l
Gas chromatography with purge and trap technique (Purge&Trap) and mass spectrometry detection (P&T GC-MS) PN-EN ISO 15680:2008
28 Water, wastewater Nitrate nitrogen and nitrite nitrogen concentration (sum)
Range (0,10 – 500) mg/l
Continuous flow analysis (CFA) with spectrophotometric detection PN-EN ISO 13395:2001
29 Water, wastewater Nitrite nitrogen concentration
Range (0,0010 – 100) mg/l
Continuous flow analysis (CFA) with spectrophotometric detection PN-EN ISO 13395:2001
30 Water, wastewater Nitrate nitrogen concentration (calculated) PN-EN ISO 13395:2001
31 Water, wastewater Nitrate concentration (calculated) PN-EN ISO 13395:2001
32 Water, wastewater Nitrite concentration (calculated) PN-EN ISO 13395:2001
33 Water, wastewater Ammonium nitrogen concentration
Range (0,01 – 100) mg/l
Spectrophotometric method PN-ISO 7150-1:2002
34 Water, wastewater Ammonium ion concentration (calculated) PN-ISO 7150-1:2002
35 Water, wastewater Ammonia concentration (calculated) PN-ISO 7150-1:2002
36 Water, wastewater Ammonium nitrogen concentration
Range (0,010 – 10) mg/l
Continuous flow analysis (CFA) with spectrophotometric detection PN-EN ISO 11732:2007
37 Water, wastewater Ammonium ion concentration (calculated) PN-EN ISO 11732:2007
38 Water, wastewater Ammonia concentration (calculated) PN-EN ISO 11732:2007
39 Water, wastewater Total nitrogen concentration (calculated) PB-26/CLB issue 1 of 16.01.2026
40 Water, wastewater Sulfate concentration
Range (10 – 5000) mg/l
Gravimetric method PN-ISO 9280:2002
41 Water, wastewater Biochemical oxygen demand - BOD5
Range (1 – 6000) mg/l O2
Electrochemical method PN-EN ISO 5815-1:2019-12
42 Water, wastewater Biochemical oxygen demand - BOD5
Range (0,6 – 6,0) mg/l O2
Electrochemical method PN-EN 1899-2:2002
43 Water, wastewater Total phosphorus concentration
Range (0,03 – 100) mg/l
Spectrophotometric method PN-EN ISO 6878:2006 chapter 8 | PN-EN ISO 6878:2006/Ap1:2010 | PN-EN ISO 6878:2006/Ap2:2010
44 Water, wastewater Dissolved orthophosphate concentration
Range (0,030 – 300) mg/l
Continuous flow analysis (CFA) with spectrophotometric detection PN-EN ISO 15681-2:2019-02
45 Water, wastewater Chemical oxygen demand - COD-Cr
Range (5 – 2000) mg/l O2
Spectrophotometric method PN-ISO 15705:2005
46 Water, wastewater Mineral oil index / petroleum hydrocarbons C10-C40
Range (0,05 – 100) mg/l
Gas chromatography with flame ionization detection (GC-FID) PN-EN ISO 9377-2:2003
47 Water, wastewater Dissolved orthophosphate concentration
Range (0,03 – 300) mg/l
Spectrophotometric method PN-EN ISO 6878:2006 chapter 4 | PN-EN ISO 6878:2006/Ap1:2010 | PN-EN ISO 6878:2006/Ap2:2010
48 Water, wastewater Metal concentrations
chromium (0,001 – 10) mg/l aluminium (0,005 – 10) mg/l manganese (0,001 – 10) mg/l copper (0,001 – 10) mg/l nickel (0,001 – 10) mg/l iron (0,005 – 10) mg/l
Electrothermal atomization atomic absorption spectrometry (ETAAS) PN-EN ISO 15586:2005
49 Water, wastewater Total organic carbon concentration
Range (2,0 – 200) mg/l
Spectrometry method in the infrared range IR PN-EN 1484:1999
50 Water, wastewater Total suspended solids (TSS)
Range (2,0 – 3000) mg/l
Gravimetric method PN-EN 872:2007+Ap1:2007
51 Water, wastewater Element concentration
zinc (0,0050 – 100) mg/l iron (0,050 – 100) mg/l manganese (0,0050 – 100) mg/l total phosphorus (0,010 – 20) mg/l
Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN ISO 11885:2009
52 Water, wastewater Mercury concentration
Range (0,013 – 100) µg/l
Atomic fluorescence spectrometry (AFS) PN-EN ISO 17852:2009
53 Water, wastewater Metal concentrations
cobalt (0,010 – 1,0) mg/l molybdenum (0,010 – 1,0) mg/l vanadium (0,010 – 2,0) mg/l beryllium (0,00020 – 1,0) mg/l silver (0,0010 – 0,1) mg/l thallium (0,0005 – 1,0) mg/l antimony (0,0005 – 0,5) mg/l copper (0,0010 – 10) mg/l chromium (0,0010 – 10) mg/l nickel (0,0010 – 10) mg/l
Inductively coupled plasma mass spectrometry (ICP-MS) PN-EN ISO 17294-2: 2024-4
Laboratory in Koszalin
54 Water Nitrite nitrogen concentration
Range (0,001 – 2,5) mg/l
Continuous flow analysis (CFA) with spectrophotometric detection PN-EN ISO 13395:2001
55 Water Dissolved ion concentration
nitrates (0,44 – 50,0) mg/l fluorides (0,10 – 10,0) mg/l sulfates (2,5 – 100) mg/l chlorides (1,0 – 300) mg/l
Ion chromatography with conductometric detection (IC-CD) PN-EN ISO 10304-1:2009 | PN-EN ISO 10304-1:2009/AC:2012
56 Water Nitrate nitrogen concentration (calculated) PN-EN ISO 10304-1:2009 | PN-EN ISO 10304-1:2009/AC:2012
57 Water Total nitrogen concentration
Range (0,03 – 200) mg/l
Continuous flow analysis (CFA) with spectrophotometric detection PN-EN ISO 11905-1:2001
58 Water Biochemical oxygen demand - BOD5
Range (0,5 – 6,0) mg/l O2
Electrochemical method PN-EN 1899-2:2002
59 Water Total concentration of calcium and magnesium (total hardness)
Range (5 – 500) mg/l CaCO3 Range (0,05 – 5) mmol/l CaCO3
Titrimetric method PN-ISO 6059:1999
60 Water Alkalinity
Range (20 – 1000) mg/l CaCO3 Range (0,2 – 10) mmol/l CaCO3
Titrimetric method PN-EN ISO 9963-1:2001 | PN-EN ISO 9963-1:2001/Ap1:2004
61 Water Kjeldahl nitrogen concentration
Range (0,3 – 10) mg/l
Titrimetric method PN-EN 25663:2001
62 Wastewater Nitrate nitrogen concentration
Range (0,10 – 250) mg/l
Spectrophotometric method PN-82/C-04576.08
63 Wastewater Nitrate concentration (calculated) PN-82/C-04576.08
64 Wastewater Kjeldahl nitrogen concentration
Range (1,0 – 100) mg/l
Titrimetric method PN-EN 25663:2001
65 Wastewater Nitrite nitrogen concentration
Range (0,005 – 25) mg/l
Continuous flow analysis (CFA) with spectrophotometric detection PN-EN ISO 13395:2001
66 Water, wastewater Ammonium nitrogen concentration
Range (0,010 – 100) mg/l
Continuous flow analysis (CFA) with spectrophotometric detection PN-EN ISO 11732:2007
67 Water, wastewater Ammonium ion concentration (calculated) PN-EN ISO 11732:2007
68 Water, wastewater Ammonium nitrogen concentration
Range (0,05 – 100) mg/l
Spectrophotometric method PN-ISO 7150-1:2002
69 Water, wastewater Ammonium ion concentration (calculated) PN-ISO 7150-1:2002
70 Water, wastewater Nitrate nitrogen and nitrite nitrogen concentration (sum)
Range (0,10 – 200) mg/l
Continuous flow analysis (CFA) with spectrophotometric detection PN-EN ISO 13395:2001
71 Water, wastewater Nitrate nitrogen concentration (calculated) PN-EN ISO 13395:2001
72 Water, wastewater Nitrate concentration (calculated) PN-EN ISO 13395:2001
73 Water, wastewater Nitrite concentration (calculated) PN-EN ISO 13395:2001
74 Water, wastewater Nitrite nitrogen concentration
Range (0,001 – 2,5) mg/l
Spectrophotometric method PN-EN 26777:1999
75 Water, wastewater Nitrite concentration (calculated) PN-EN 26777:1999
76 Water, wastewater Total nitrogen concentration (calculated) PN-73/C-04576.14
77 Water, wastewater Biochemical oxygen demand - BOD5
Range (1 – 6000) mg/l O2
Electrochemical method PN-EN ISO 5815-1:2019-12
78 Water, wastewater Chemical oxygen demand - COD-Cr
Range (4,0 – 10000) mg/l O2
Spectrophotometric method PN-ISO 15705:2005
79 Water, wastewater Chloride concentration
Range (5,0 – 10000) mg/l
Titrimetric method PN-ISO 9297:1994
80 Water, wastewater Phosphorus concentration
Range (0,005 – 200,0) mg/l
Spectrophotometric method PN-EN ISO 6878:2006 cl. 7 | PN-EN ISO 6878:2006/Ap1:2010 | PN-EN ISO 6878:2006/Ap2:2010
81 Water, wastewater Orthophosphate concentration
Range (0,015 – 25,0) mg/l
Spectrophotometric method PN-EN ISO 6878:2006 cl. 4 | PN-EN ISO 6878:2006/Ap1:2010 | PN-EN ISO 6878:2006/Ap2:2010
82 Water, wastewater Sulfate concentration
Range (10 – 5000) mg/l
Gravimetric method PN-ISO 9280:2002
83 Water, wastewater Dissolved solids concentration
Range (1 – 3000) mg/l
Gravimetric method PN-EN 15216:2022-03
84 Water, wastewater Calcium concentration
Range (2 – 200) mg/l
Titrimetric method PN-ISO 6058:1999
85 Water, wastewater Total suspended solids (TSS)
Range (2,0 – 3000) mg/l
Gravimetric method PN-EN 872:2007 | PN-EN 872:2007/Ap1:2007

Reference standards (53)

ISO 17289:2014
PB-26/CLB issue 1 of 16.01.2026
PN-73/C-04576.14
PN-77/C-04584
PN-82/C-04576.08
PN-EN 1484:1999
PN-EN 15216:2022-03
PN-EN 1899-2:2002
PN-EN 25663:2001
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007
PN-EN 872:2007+Ap1:2007
PN-EN 872:2007/Ap1:2007
PN-EN ISO 10304-1:2009
PN-EN ISO 10304-1:2009/AC:2012
PN-EN ISO 10523:2012
PN-EN ISO 11732:2007
PN-EN ISO 11885:2009
PN-EN ISO 11905-1:2001
PN-EN ISO 13395:2001
PN-EN ISO 14402:2004 cl. 4
PN-EN ISO 14911:2002
PN-EN ISO 15586:2005
PN-EN ISO 15680:2008
PN-EN ISO 15681-2:2019-02
PN-EN ISO 17294-2: 2024-4
PN-EN ISO 17852:2009
PN-EN ISO 5667-6:2016-12 excluding cl. 9.2 and 9.4
PN-EN ISO 5814:2013-04
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6878:2006 cl. 4
PN-EN ISO 6878:2006 cl. 7
PN-EN ISO 6878:2006 chapter 4
PN-EN ISO 6878:2006 chapter 7
PN-EN ISO 6878:2006 chapter 8
PN-EN ISO 6878:2006/Ap1:2010
PN-EN ISO 6878:2006/Ap2:2010
PN-EN ISO 9377-2:2003
PN-EN ISO 9963-1:2001
PN-EN ISO 9963-1:2001/Ap1:2004
PN-ISO 15705:2005
PN-ISO 5667-10:2021-11
PN-ISO 5667-11:2017-10 excluding cl. 5.2, 6.1.2, 6.2, 6.3
PN-ISO 5667-4:2017-10
PN-ISO 5667-9:2005
PN-ISO 6058:1999
PN-ISO 6059:1999
PN-ISO 7150-1:2002
PN-ISO 9280:2002
PN-ISO 9297:1994
Annex 7 to the Regulation of the Minister of Climate and Environment of 7 September 2021 (consolidated text Journal of Laws of 2023, item 1706) excluding cl. F
Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630)

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/PL/AB%20177