🇵🇱 LABORATORIUM AQUA-CRISTAL PL

PCA AB 1719 • Powroźnik, Poland • 75 methods

Water & wastewaterMicrobiology

LABORATORIUM AQUA-CRISTAL is a laboratory accredited by PCA under number AB 1719 (Powroźnik, Poland). Its accreditation scope covers 75 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water intended for human consumption, Spring water, Mineral water, Swimming pool water, Water intended for human consumption, Spring water, Mineral water. Most frequently used techniques: Spectrophotometric method, Membrane filtration method, Titrimetric method.

At a glance

  • Accreditation number: PCA AB 1719
  • Methods in scope: 75
  • Types of test objects: 6
  • Techniques used: 8
  • City: Powroźnik, Poland
Accreditation number
AB 1719
Accreditation body
PCA
Address
KATARZYNA LUBIAK, ul. Osiedlowa 8, 33-370 Powroźnik
City
Powroźnik, Poland

What this laboratory tests (6)

Analytical techniques used (8)

Laboratory locations

Certificate information

Issue date
16.09.2026
Issue no.
8

Accreditation scope — test methods (75)

No. Test object Methodology / Parameters Technique Reference document
AQUA-CRISTAL Laboratory
1 Water intended for human consumption Sampling for microbiological testing
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
PN-EN ISO 19458:2007
2 Water intended for human consumption Temperature
Range (2,0 – 80,0) °C
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
PBL-15 issue II of 02.02.2018
3 Water intended for human consumption Coliform bacteria count
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04
4 Water intended for human consumption Escherichia coli count
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04
5 Water intended for human consumption Total number of microorganisms at 22 ºC
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
Plate method (pour plate) PN-EN ISO 6222:2004
6 Water intended for human consumption Total number of microorganisms at 36 ºC
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
Plate method (pour plate) PN-EN ISO 6222:2004
7 Water intended for human consumption Intestinal enterococci count
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
Membrane filtration method PN-EN ISO 7899-2:2004
8 Water intended for human consumption Pseudomonas aeruginosa count
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
Membrane filtration method PN-EN ISO 16266:2009
9 Water intended for human consumption Count of bacteria of the genus Legionella
Matrix A: Procedure 5 (medium A), Procedure 7 (medium C-GVPC)
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
Membrane filtration method PN-EN ISO 11731:2017-08 +Ap1:2019-12
10 Water intended for human consumption Sampling for chemical and physical testing
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
PN-ISO 5667-5:2017-10
11 Water intended for human consumption Temperature
Range (2,0 – 80,0) °C
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
PBL-15 issue II of 02.02.2018
12 Water intended for human consumption Colour
Range (2 – 250) mg/l Pt
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
Spectrophotometric method PN-EN ISO 7887:2012+Ap1:2015-06 Method C
13 Water intended for human consumption Free chlorine concentration
Range (0,02 – 2,00) mg/l
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
Spectrophotometric method Hach Lange test No. 8021 edition 9 of 01.2014
14 Water intended for human consumption Total chlorine concentration
Range (0,04 – 2,00) mg/l
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
Spectrophotometric method Hach Lange test No. 8167, edition 11 of 01.2022
15 Water intended for human consumption Combined chlorine (chloramine) concentration (calculated)
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
PBL-14 issue II of 31.01.2018
16 Water intended for human consumption Turbidity
Range (0,1 – 20,00) NTU
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
Nephelometric method PN-EN ISO 7027-1:2016-09
17 Water intended for human consumption Aluminium concentration
Range (20 – 500) μg/l
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
Spectrophotometric method HACH LANGE test No. LCK 301, edition 2 of 12.2021
18 Water intended for human consumption Permanganate index
Range (0,5 – 20,0) mg/l O2
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
Titrimetric method PN-EN ISO 8467:2001
19 Water intended for human consumption Nitrate concentration
Range (1 – 60,00) mg/l
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
Spectrophotometric method HACH LANGE LCK test No. 339, edition 2 of 06.2025
20 Water intended for human consumption Nitrite concentration
Range (0,05 – 2,00) mg/l
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
Spectrophotometric method HACH LANGE test No. LCK 341, edition 2 of 06.2025
21 Water intended for human consumption Ammonium ion concentration
Range (0,03 – 3,25) mg/l
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
Spectrophotometric method HACH LANGE method No. 8038, edition 9 of 04.2017
22 Water intended for human consumption Iron concentration
Range (20 – 3000) μg/l
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
Spectrophotometric method HACH LANGE method No. 8008 edition 9 of 01.2014
23 Water intended for human consumption Manganese concentration
Range (6 – 700) μg/l
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
Spectrophotometric method HACH LANGE method No. 8149, edition 11 of 02.2024
24 Water intended for human consumption Total content of calcium and magnesium (total hardness)
Range (5 – 1000) mg/l CaCO3
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
Titrimetric method PN-ISO 6059:1999
25 Water intended for human consumption Calcium concentration
Range (2 – 400) mg/l
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
Titrimetric method PN-ISO 6058:1999
26 Water intended for human consumption Magnesium concentration (calculated)
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
PN-C-04554-4:1999
27 Water intended for human consumption Chloride concentration
Range (5 – 300)mg/l
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
Titrimetric method PN-ISO 9297:1994
28 Water intended for human consumption pH
Range 4,0 – 10,0
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
Potentiometric method PN-EN ISO 10523:2012
29 Water intended for human consumption Electrical conductivity
Range (10 – 3000) μS/cm
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
Conductometric method PN-EN 27888:1999
30 Water intended for human consumption Sodium concentration
Range (10 – 400) mg/l
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
Potentiometric method HACH LANGE method No. 8322 edition 10 of 02.2021
31 Water intended for human consumption Sulfate concentration
Range (2 – 250) mg/l
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
Spectrophotometric method HACH LANGE method No. 8051, edition 1 of 08.2005
32 Water intended for human consumption Fluoride concentration
Range (0,02 - 2,00) mg/l
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
Spectrophotometric method HACH LANGE method No. 8029, edition 9 of 01.2014
33 Swimming pool water Sampling for chemical and physical testing PBL-22 issue II of 14.07.2021
34 Swimming pool water Temperature
Range (2,0 – 50,0) °C
PBL-15 issue II of 02.02.2018
35 Swimming pool water Oxidation-reduction (redox) potential vs. Ag/AgCl 3,5 mol/l KCl
Range (200 – 1000) mV
Potentiometric method PBL-12 issue II of 31.01.2018
36 Swimming pool water pH
Range 4,0 – 9,0
Potentiometric method PN-EN ISO 10523:2012
37 Water Colour
Range (2 – 250) mg/l Pt
Spectrophotometric method PN-EN ISO 7887:2012+Ap1:2015-06 Method C
38 Swimming pool water Free chlorine concentration
Range (0,02 – 2,00) mg/l
Spectrophotometric method Hach Lange test No. 8167, edition 11 of 01.2022
39 Swimming pool water Total chlorine concentration
Range (0,04 – 2,00) mg/l
Spectrophotometric method Hach Lange test No. 8167, edition 11 of 01.2022
40 Swimming pool water Combined chlorine concentration (calculated) PBL-14 issue II of 31.01.2018
41 Swimming pool water Aluminium concentration
Range (20 – 500) µg/l
Spectrophotometric method HACH LANGE test No. LCK 301, edition 2 of 12.2021
42 Swimming pool water Turbidity
Range (0,1 – 20,00) NTU
Nephelometric method PN-EN ISO 7027-1:2016-09
43 Swimming pool water Permanganate index (oxidisability)
Range (0,5 – 20,0) mg/l O2
Titrimetric method PN-EN ISO 8467:2001
44 Swimming pool water, Spring water, Mineral water Nitrate concentration
Range (1 – 60,00) mg/l
Spectrophotometric method HACH LANGE LCK test No. 339, edition 2 of 06.2025
45 Spring water, Mineral water Nitrite concentration
Range (0,05 – 2,00) mg/l
Spectrophotometric method HACH LANGE test No. LCK 341, edition 2 of 06.2025
46 Spring water, Mineral water Ammonium ion concentration
Range (0,03 – 3,25) mg/l
Spectrophotometric method HACH LANGE method No. 8038, edition 9 of 04.2017
47 Spring water, Mineral water Iron concentration
Range (20 – 3000) µg/l
Spectrophotometric method HACH LANGE method No. 8008 edition 9 of 01.2014
48 Spring water, Mineral water Manganese concentration
Range (6 – 700) µg/l
Spectrophotometric method HACH LANGE method No. 8149, edition 11 of 02.2024
49 Spring water, Mineral water Total hardness (total content of calcium and magnesium)
Range (5 – 1000) mg/l CaCO3
Titrimetric method PN-ISO 6059:1999
50 Spring water, Mineral water Calcium concentration
Range (2 – 400) mg/l
Titrimetric method PN-ISO 6058:1999
51 Spring water, Mineral water Magnesium concentration (calculated) PN-C-04554-4:1999
52 Spring water, Mineral water Chloride concentration
Range (5 – 300)mg/l
Titrimetric method PN-ISO 9297:1994
53 Spring water, Mineral water pH
Range 4,0 – 10,0
Potentiometric method PN-EN ISO 10523:2012
54 Spring water, Mineral water Electrical conductivity
Range (10 – 3000) µS/cm
Conductometric method PN-EN 27888:1999
55 Spring water, Mineral water Sodium concentration
Range (10 – 400) mg/l
Potentiometric method HACH LANGE method No. 8322 edition 10 of 02.2021
56 Spring water, Mineral water Sulfate concentration
Range (2 – 250) mg/l
Spectrophotometric method HACH LANGE method No. 8051, edition 1 of 08.2005
57 Water intended for human consumption, Spring water, Mineral water Potassium concentration
Range (0,1 – 7,0) mg/l
Spectrophotometric method PBL-08 issue IV of 29.01.2018 based on the HACH LANGE method No. 8049
58 Water intended for human consumption, Spring water, Mineral water Total alkalinity
Range (0,40 – 100) mmol/l Mineral alkalinity (0,40 – 100) mmol/l
Potentiometric titration method PN-EN ISO 9963-1:2001 cl. 8.1 | PN-EN ISO 9963-1:2001/Ap1:2004
59 Water intended for human consumption, Spring water, Mineral water Concentration of acid carbonates (hydrogen carbonates) (calculated) PN-EN ISO 9963-1:2001 cl. 8.1 | PN-EN ISO 9963-1:2001/Ap1:2004 Annex A
60 Water intended for human consumption, Spring water, Mineral water Barium concentration
Range (0,06 - 10) mg/l
Spectrophotometric method PBL-45 issue II of 29.03.2023 based on the HACH LANGE method No. 8014
61 Water intended for human consumption, Spring water, Mineral water Fluoride concentration
Range (0,02 - 2,00) mg/l
Spectrophotometric method HACH LANGE method No. 8029, edition 9 of 01.2014
62 Water intended for human consumption, Spring water, Mineral water Sum of mineral components (total mineralisation) calculated PBL-43 issue II of 29.03.2023
63 Spring water, Mineral water Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12 /A1:2017-04
64 Spring water, Mineral water Escherichia coli count Membrane filtration method PBL-39 issue I of 15.07.2020
65 Spring water, Mineral water Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004
66 Spring water, Mineral water Count of Pseudomonas aerugionosa Membrane filtration method PN-EN ISO 16266:2009
67 Spring water, Mineral water Total count of microorganisms at 37 °C Plate method (pour plate) PBL-37 issue I of 12.07.2018
68 Spring water, Mineral water Total viable count at 22 °C Plate method (pour plate) PBL-37 issue I of 12.07.2018
69 Spring water, Mineral water Count of spores of sulphite-reducing anaerobes (Clostridia) Membrane filtration method PN-EN 26461-2:2001
70 Swimming pool water Number of coagulase-positive staphylococci Membrane filtration method PZH ZHK:2007
71 Swimming pool water Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12 /A1:2017-04
72 Swimming pool water Count of Pseudomonas aerugionosa Membrane filtration method PN-EN ISO 16266:2009
73 Swimming pool water Total viable count at 36 °C Plate method (pour plate) PN-EN ISO 6222:2004
74 Swimming pool water Count of Legionella sp. bacteria
Matrix A: Procedure 5 (medium A), Procedure 7 (medium C-GVPC)
Membrane filtration method PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08 /Ap1:2019-12
75 Swimming pool water Sampling for microbiological testing PN-EN ISO 19458:2007

Reference standards (45)

HACH LANGE method No. 8008 edition 9 of 01.2014
HACH LANGE method No. 8029, edition 9 of 01.2014
HACH LANGE method No. 8038, edition 9 of 04.2017
HACH LANGE method No. 8051, edition 1 of 08.2005
HACH LANGE method No. 8149, edition 11 of 02.2024
HACH LANGE method No. 8322 edition 10 of 02.2021
PBL-08 issue IV of 29.01.2018 based on the HACH LANGE method No. 8049
PBL-12 issue II of 31.01.2018
PBL-14 issue II of 31.01.2018
PBL-15 issue II of 02.02.2018
PBL-22 issue II of 14.07.2021
PBL-37 issue I of 12.07.2018
PBL-39 issue I of 15.07.2020
PBL-43 issue II of 29.03.2023
PBL-45 issue II of 29.03.2023 based on the HACH LANGE method No. 8014
PN-C-04554-4:1999
PN-EN 26461-2:2001
PN-EN 27888:1999
PN-EN ISO 10523:2012
PN-EN ISO 11731:2017-08
PN-EN ISO 11731:2017-08 +Ap1:2019-12
PN-EN ISO 11731:2017-08 /Ap1:2019-12
PN-EN ISO 16266:2009
PN-EN ISO 19458:2007
PN-EN ISO 6222:2004
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7887:2012+Ap1:2015-06 Method C
PN-EN ISO 7899-2:2004
PN-EN ISO 8467:2001
PN-EN ISO 9308-1:2014-12
PN-EN ISO 9308-1:2014-12 +A1:2017-04
PN-EN ISO 9308-1:2014-12 /A1:2017-04
PN-EN ISO 9963-1:2001 cl. 8.1
PN-EN ISO 9963-1:2001/Ap1:2004
PN-EN ISO 9963-1:2001/Ap1:2004 Annex A
PN-ISO 5667-5:2017-10
PN-ISO 6058:1999
PN-ISO 6059:1999
PN-ISO 9297:1994
PZH ZHK:2007
HACH LANGE LCK test No. 339, edition 2 of 06.2025
HACH LANGE test No. LCK 341, edition 2 of 06.2025
Hach Lange test No. 8021 edition 9 of 01.2014
Hach Lange test No. 8167, edition 11 of 01.2022
HACH LANGE test No. LCK 301, edition 2 of 12.2021

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/PL/AB%201719