🇵🇱 SPIE ENERGY POLAND S.A. PL

PCA AB 1712 • Gdańsk, Poland • 10 methods

Environment

SPIE ENERGY POLAND S.A. is a laboratory accredited by PCA under number AB 1712 (Gdańsk, Poland). Its accreditation scope covers 10 test methods in the following areas: Environment. Test objects include: Environment – electromagnetic field in the vicinity of electric pow…, Workplace environment – electromagnetic field in the workspace duri…, General environment – noise from installations, equipment and indus…, Workplace environment – noise. Most frequently used techniques: Direct measurement method.

At a glance

  • Accreditation number: PCA AB 1712
  • Methods in scope: 10
  • Types of test objects: 4
  • Techniques used: 1
  • City: Gdańsk, Poland
Accreditation number
AB 1712
Accreditation body
PCA
Address
LABORATORIUM BADAWCZE, ul. Marynarki Polskiej 87, 80-557 Gdańsk
City
Gdańsk, Poland

What this laboratory tests (4)

Analytical techniques used (1)

Certificate information

Issue date
26.11.2024
Issue no.
10

Accreditation scope — test methods (10)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Workplace environment – electromagnetic field in the workspace during the use of power systems and alternating current electrical supply installations in the power industry Electric field strength in the frequency range:
45 Hz – 55 Hz Range (1 –40 000) V/m
Direct measurement method Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 91–150
2 Workplace environment – electromagnetic field in the workspace during the use of power systems and alternating current electrical supply installations in the power industry Magnetic flux density in the frequency range:
45 Hz – 55 Hz Range 0,5 μT – 19 mT
Direct measurement method Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 91–150
3 Workplace environment – electromagnetic field in the workspace during the use of power systems and alternating current electrical supply installations in the power industry Magnetic field strength (calculated) Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 91–150
4 Environment – electromagnetic field in the vicinity of electric power substations and power lines Electric field strength
in the frequency range 50 Hz Range (100 –40 000) V/m
Direct measurement method Annex to the Regulation of the Minister of Climate of 17 February 2020 (consolidated text Journal of Laws 2022 item 2630)
5 Environment – electromagnetic field in the vicinity of electric power substations and power lines Magnetic flux density
in the frequency range 50 Hz Range (0,5 – 19 000) μT
Direct measurement method Annex to the Regulation of the Minister of Climate of 17 February 2020 (consolidated text Journal of Laws 2022 item 2630)
6 Environment – electromagnetic field in the vicinity of electric power substations and power lines Magnetic field strength
in the frequency range 50 Hz (calculated)
Annex to the Regulation of the Minister of Climate of 17 February 2020 (consolidated text Journal of Laws 2022 item 2630)
7 General environment – noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level
Range (25 – 136) dB
Direct measurement method Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023, item 1706) excluding cl. F
8 General environment – noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023, item 1706) excluding cl. F
9 Workplace environment – noise A-weighted equivalent sound level Maximum A-weighted sound level
Range (25 – 136) dB C-weighted peak sound pressure level Range (35 –140) dB
Direct measurement method PN-N-01307:1994 | PN-EN ISO 9612:2011 excluding the method covering strategies 2 (cl. 10) and 3 cl. 11
10 Workplace environment – noise Noise exposure level referred to:
an 8-hour daily working time the average weekly working time (calculated)
PN-N-01307:1994 | PN-EN ISO 9612:2011 excluding the method covering strategies 2 (cl. 10) and 3 cl. 11

Reference standards (5)

PN-EN ISO 9612:2011 excluding the method covering strategies 2 (cl. 10) and 3 cl. 11
PN-N-01307:1994
Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 91–150
Annex to the Regulation of the Minister of Climate of 17 February 2020 (consolidated text Journal of Laws 2022 item 2630)
Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023, item 1706) excluding cl. F

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/PL/AB%201712