🇵🇱 STREFA MICHAŁ GRĄCKI PL
EnvironmentElectronics & EMC
STREFA MICHAŁ GRĄCKI is a laboratory accredited by PCA under number AB 1709 (Zajezierze, Poland). Its accreditation scope covers 22 test methods in the following areas: Environment, Electronics & EMC. Test objects include: Workplace environment − electromagnetic field originating from equi…, Workplace environment − electromagnetic field originating from indu…, Workplace environment - electromagnetic field from transmitting dev…, Workplace environment - electromagnetic field from transmitting dev…. Most frequently used techniques: Direct measurement method, Direct measurement method (simplified).
At a glance
- Accreditation number: PCA AB 1709
- Methods in scope: 22
- Types of test objects: 8
- Techniques used: 2
- City: Zajezierze, Poland
- Accreditation number
- AB 1709
- Accreditation body
- PCA
- Address
- Zajezierze 8E, 88-140 Zajezierze
- City
- Zajezierze, Poland
What this laboratory tests (8)
- Workplace environment − electromagnetic field originating from equipment used in medical technology: - physiotherapeutic diathermy - magnetic resonance scanners — 4 methods
- Workplace environment − electromagnetic field originating from industrial installations and equipment: - NMR spectrometers - dielectric heating equipment - special equipment: radio frequency defrosting device — 4 methods
- Workplace environment - electromagnetic field from transmitting devices of radiocommunication systems (base stations of mobile telephony systems) — 3 methods
- Workplace environment - electromagnetic field from transmitting devices of radiocommunication systems (broadcasting tele- and radiocommunication systems - radio, television, etc.) — 3 methods
- Workplace environment − electromagnetic field from radiocommunication and anti-theft systems: - hand-held and cordless radiotelephones, short-range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) - anti-theft and electronic article surveillance systems — 3 methods
- Environment – electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) — 2 methods
- Environment – electromagnetic field in the vicinity of radiocommunication installations (selective measurements) — 2 methods
- Workplace environment - electromagnetic field in the workspace from magnetotherapy devices — 1 method
Analytical techniques used (2)
- Direct measurement method — 14 methods
- Direct measurement method (simplified) — 1 method
Certificate information
- Issue date
- 25.02.2026
- Issue no.
- 10
Accreditation scope — test methods (22)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Environment – electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) | Electric field strength: in the frequency range from 80 MHz up to 90 GHz Range (0,5 – 300) V/m |
Direct measurement method | Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630) | |
| 2 | Environment – electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) | Magnetic field strength: in the frequency range from 80 MHz up to 90 GHz (calculated) |
Clause 3 of the Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630) | ||
| 3 | Environment – electromagnetic field in the vicinity of radiocommunication installations (selective measurements) | Electric field strength: in the frequency range from 27 MHz up to 4 GHz Range 0,2 V/m – 255 V/m |
Direct measurement method | Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630) | |
| 4 | Environment – electromagnetic field in the vicinity of radiocommunication installations (selective measurements) | Magnetic field strength: in the frequency range from 27 MHz up to 4 GHz (calculated) |
Clause 3 of the Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630) | ||
| 5 | Workplace environment - electromagnetic field in the workspace from magnetotherapy devices | Magnetic flux density: in the frequency range from 30 Hz up to 50 Hz Range 0,5 μT – 1,9 mT |
Direct measurement method (simplified) | Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 151–180 | |
| 6 | Workplace environment - electromagnetic field from transmitting devices of radiocommunication systems (base stations of mobile telephony systems) | Electric field strength: in the frequency range from 420 MHz up to 90 GHz Range (0,5 – 300) V/m |
Direct measurement method | Principles and Methods of Assessing the Working Environment 2017, No. 2 (92), pp. 89–131 | |
| 7 | Workplace environment - electromagnetic field from transmitting devices of radiocommunication systems (base stations of mobile telephony systems) | Magnetic field strength: in the frequency range from 420 MHz up to 800 MHz Range (0,01 – 2) A/m |
Direct measurement method | Principles and Methods of Assessing the Working Environment 2017, No. 2 (92), pp. 89–131 | |
| 8 | Workplace environment - electromagnetic field from transmitting devices of radiocommunication systems (base stations of mobile telephony systems) | Magnetic field strength: in the frequency range from 800 MHz up to 90 GHz (calculated) |
Principles and Methods of Assessing the Working Environment 2017, No. 2 (92), pp. 89–131 | ||
| 9 | Workplace environment - electromagnetic field from transmitting devices of radiocommunication systems (broadcasting tele- and radiocommunication systems - radio, television, etc.) | Electric field strength: in the frequency range from 85 MHz up to 90 GHz Range (0,5 – 300) V/m |
Direct measurement method | Principles and Methods of Assessing the Working Environment 2017, No. 2 (92), pp. 89–131 | |
| 10 | Workplace environment - electromagnetic field from transmitting devices of radiocommunication systems (broadcasting tele- and radiocommunication systems - radio, television, etc.) | Magnetic field strength: in the frequency range from 85 MHz up to 1 GHz Range (0,01 – 2) A/m |
Direct measurement method | Principles and Methods of Assessing the Working Environment 2017, No. 2 (92), pp. 89–131 | |
| 11 | Workplace environment - electromagnetic field from transmitting devices of radiocommunication systems (broadcasting tele- and radiocommunication systems - radio, television, etc.) | Magnetic field strength: in the frequency range from 800 MHz up to 90 GHz (calculated) |
Principles and Methods of Assessing the Working Environment 2017, No. 2 (92), pp. 89–131 | ||
| 12 | Workplace environment − electromagnetic field originating from industrial installations and equipment: - NMR spectrometers - dielectric heating equipment - special equipment: radio frequency defrosting device | Magnetic flux density: in the frequency range 0 Hz Range 100 μT − 1000 mT |
Direct measurement method | PN-T-06580-3:2002 | PB-01 test procedure issue 1 of 24.09.2018 | PB-02 test procedure issue 3 of 04.01.2022 | |
| 13 | Workplace environment − electromagnetic field originating from industrial installations and equipment: - NMR spectrometers - dielectric heating equipment - special equipment: radio frequency defrosting device | Electric field strength: in the frequency range from 27 MHz up to 3 GHz Range (0,5 − 300) V/m |
Direct measurement method | PN-T-06580-3:2002 | PB-01 test procedure issue 1 of 24.09.2018 | PB-02 test procedure issue 3 of 04.01.2022 | |
| 14 | Workplace environment − electromagnetic field originating from industrial installations and equipment: - NMR spectrometers - dielectric heating equipment - special equipment: radio frequency defrosting device | Magnetic field strength: in the frequency range from 27 MHz up to 1 GHz Range (0,01 – 2) A/m |
Direct measurement method | PN-T-06580-3:2002 | PB-01 test procedure issue 1 of 24.09.2018 | PB-02 test procedure issue 3 of 04.01.2022 | |
| 15 | Workplace environment − electromagnetic field originating from industrial installations and equipment: - NMR spectrometers - dielectric heating equipment - special equipment: radio frequency defrosting device | Magnetic field strength: in the frequency range from 1 GHz up to 3 GHz (calculated) |
PN-T-06580-3:2002 | PB-01 test procedure issue 1 of 24.09.2018 | PB-02 test procedure issue 3 of 04.01.2022 | ||
| 16 | Workplace environment − electromagnetic field from radiocommunication and anti-theft systems: - hand-held and cordless radiotelephones, short-range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) - anti-theft and electronic article surveillance systems | Electric field strength: in the frequency range from 27 MHz up to 3 GHz Range (0,5 − 300) V/m |
Direct measurement method | PN-T-06580-3:2002 | PB-01 test procedure issue 1 of 24.09.2018 | PB-02 test procedure issue 3 of 04.01.2022 | |
| 17 | Workplace environment − electromagnetic field from radiocommunication and anti-theft systems: - hand-held and cordless radiotelephones, short-range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) - anti-theft and electronic article surveillance systems | Magnetic field strength: in the frequency range from 27 MHz up to 1 GHz Range (0,01 – 2) A/m |
Direct measurement method | PN-T-06580-3:2002 | PB-01 test procedure issue 1 of 24.09.2018 | PB-02 test procedure issue 3 of 04.01.2022 | |
| 18 | Workplace environment − electromagnetic field from radiocommunication and anti-theft systems: - hand-held and cordless radiotelephones, short-range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) - anti-theft and electronic article surveillance systems | Magnetic field strength: in the frequency range from 1 GHz up to 3 GHz (calculated) |
PN-T-06580-3:2002 | PB-01 test procedure issue 1 of 24.09.2018 | PB-02 test procedure issue 3 of 04.01.2022 | ||
| 19 | Workplace environment − electromagnetic field originating from equipment used in medical technology: - physiotherapeutic diathermy - magnetic resonance scanners | Magnetic flux density: in the frequency range 0 Hz Range 100 μT − 1000 mT |
Direct measurement method | PN-T-06580-3:2002 | PB-01 test procedure issue 1 of 24.09.2018 | PB-02 test procedure issue 3 of 04.01.2022 | |
| 20 | Workplace environment − electromagnetic field originating from equipment used in medical technology: - physiotherapeutic diathermy - magnetic resonance scanners | Electric field strength: in the frequency range from 27 MHz up to 3 GHz Range (0,5 − 300) V/m |
Direct measurement method | PN-T-06580-3:2002 | PB-01 test procedure issue 1 of 24.09.2018 | PB-02 test procedure issue 3 of 04.01.2022 | |
| 21 | Workplace environment − electromagnetic field originating from equipment used in medical technology: - physiotherapeutic diathermy - magnetic resonance scanners | Magnetic field strength: in the frequency range from 27 MHz up to 1 GHz Range (0,01 – 2) A/m |
Direct measurement method | PN-T-06580-3:2002 | PB-01 test procedure issue 1 of 24.09.2018 | PB-02 test procedure issue 3 of 04.01.2022 | |
| 22 | Workplace environment − electromagnetic field originating from equipment used in medical technology: - physiotherapeutic diathermy - magnetic resonance scanners | Magnetic field strength: in the frequency range from 1 GHz up to 3 GHz (calculated) |
PN-T-06580-3:2002 | PB-01 test procedure issue 1 of 24.09.2018 | PB-02 test procedure issue 3 of 04.01.2022 | ||
Reference standards (7)
PB-01 test procedure issue 1 of 24.09.2018
PB-02 test procedure issue 3 of 04.01.2022
PN-T-06580-3:2002
Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 151–180
Principles and Methods of Assessing the Working Environment 2017, No. 2 (92), pp. 89–131
Clause 3 of the Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630)
Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630)