🇵🇱 STREFA MICHAŁ GRĄCKI PL

PCA AB 1709 • Zajezierze, Poland • 22 methods

EnvironmentElectronics & EMC

STREFA MICHAŁ GRĄCKI is a laboratory accredited by PCA under number AB 1709 (Zajezierze, Poland). Its accreditation scope covers 22 test methods in the following areas: Environment, Electronics & EMC. Test objects include: Workplace environment − electromagnetic field originating from equi…, Workplace environment − electromagnetic field originating from indu…, Workplace environment - electromagnetic field from transmitting dev…, Workplace environment - electromagnetic field from transmitting dev…. Most frequently used techniques: Direct measurement method, Direct measurement method (simplified).

At a glance

  • Accreditation number: PCA AB 1709
  • Methods in scope: 22
  • Types of test objects: 8
  • Techniques used: 2
  • City: Zajezierze, Poland
Accreditation number
AB 1709
Accreditation body
PCA
Address
Zajezierze 8E, 88-140 Zajezierze
City
Zajezierze, Poland

What this laboratory tests (8)

Analytical techniques used (2)

Certificate information

Issue date
25.02.2026
Issue no.
10

Accreditation scope — test methods (22)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Environment – electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) Electric field strength:
in the frequency range from 80 MHz up to 90 GHz Range (0,5 – 300) V/m
Direct measurement method Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630)
2 Environment – electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) Magnetic field strength:
in the frequency range from 80 MHz up to 90 GHz (calculated)
Clause 3 of the Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630)
3 Environment – electromagnetic field in the vicinity of radiocommunication installations (selective measurements) Electric field strength:
in the frequency range from 27 MHz up to 4 GHz Range 0,2 V/m – 255 V/m
Direct measurement method Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630)
4 Environment – electromagnetic field in the vicinity of radiocommunication installations (selective measurements) Magnetic field strength:
in the frequency range from 27 MHz up to 4 GHz (calculated)
Clause 3 of the Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630)
5 Workplace environment - electromagnetic field in the workspace from magnetotherapy devices Magnetic flux density:
in the frequency range from 30 Hz up to 50 Hz Range 0,5 μT – 1,9 mT
Direct measurement method (simplified) Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 151–180
6 Workplace environment - electromagnetic field from transmitting devices of radiocommunication systems (base stations of mobile telephony systems) Electric field strength:
in the frequency range from 420 MHz up to 90 GHz Range (0,5 – 300) V/m
Direct measurement method Principles and Methods of Assessing the Working Environment 2017, No. 2 (92), pp. 89–131
7 Workplace environment - electromagnetic field from transmitting devices of radiocommunication systems (base stations of mobile telephony systems) Magnetic field strength:
in the frequency range from 420 MHz up to 800 MHz Range (0,01 – 2) A/m
Direct measurement method Principles and Methods of Assessing the Working Environment 2017, No. 2 (92), pp. 89–131
8 Workplace environment - electromagnetic field from transmitting devices of radiocommunication systems (base stations of mobile telephony systems) Magnetic field strength:
in the frequency range from 800 MHz up to 90 GHz (calculated)
Principles and Methods of Assessing the Working Environment 2017, No. 2 (92), pp. 89–131
9 Workplace environment - electromagnetic field from transmitting devices of radiocommunication systems (broadcasting tele- and radiocommunication systems - radio, television, etc.) Electric field strength:
in the frequency range from 85 MHz up to 90 GHz Range (0,5 – 300) V/m
Direct measurement method Principles and Methods of Assessing the Working Environment 2017, No. 2 (92), pp. 89–131
10 Workplace environment - electromagnetic field from transmitting devices of radiocommunication systems (broadcasting tele- and radiocommunication systems - radio, television, etc.) Magnetic field strength:
in the frequency range from 85 MHz up to 1 GHz Range (0,01 – 2) A/m
Direct measurement method Principles and Methods of Assessing the Working Environment 2017, No. 2 (92), pp. 89–131
11 Workplace environment - electromagnetic field from transmitting devices of radiocommunication systems (broadcasting tele- and radiocommunication systems - radio, television, etc.) Magnetic field strength:
in the frequency range from 800 MHz up to 90 GHz (calculated)
Principles and Methods of Assessing the Working Environment 2017, No. 2 (92), pp. 89–131
12 Workplace environment − electromagnetic field originating from industrial installations and equipment: - NMR spectrometers - dielectric heating equipment - special equipment: radio frequency defrosting device Magnetic flux density:
in the frequency range 0 Hz Range 100 μT − 1000 mT
Direct measurement method PN-T-06580-3:2002 | PB-01 test procedure issue 1 of 24.09.2018 | PB-02 test procedure issue 3 of 04.01.2022
13 Workplace environment − electromagnetic field originating from industrial installations and equipment: - NMR spectrometers - dielectric heating equipment - special equipment: radio frequency defrosting device Electric field strength:
in the frequency range from 27 MHz up to 3 GHz Range (0,5 − 300) V/m
Direct measurement method PN-T-06580-3:2002 | PB-01 test procedure issue 1 of 24.09.2018 | PB-02 test procedure issue 3 of 04.01.2022
14 Workplace environment − electromagnetic field originating from industrial installations and equipment: - NMR spectrometers - dielectric heating equipment - special equipment: radio frequency defrosting device Magnetic field strength:
in the frequency range from 27 MHz up to 1 GHz Range (0,01 – 2) A/m
Direct measurement method PN-T-06580-3:2002 | PB-01 test procedure issue 1 of 24.09.2018 | PB-02 test procedure issue 3 of 04.01.2022
15 Workplace environment − electromagnetic field originating from industrial installations and equipment: - NMR spectrometers - dielectric heating equipment - special equipment: radio frequency defrosting device Magnetic field strength:
in the frequency range from 1 GHz up to 3 GHz (calculated)
PN-T-06580-3:2002 | PB-01 test procedure issue 1 of 24.09.2018 | PB-02 test procedure issue 3 of 04.01.2022
16 Workplace environment − electromagnetic field from radiocommunication and anti-theft systems: - hand-held and cordless radiotelephones, short-range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) - anti-theft and electronic article surveillance systems Electric field strength:
in the frequency range from 27 MHz up to 3 GHz Range (0,5 − 300) V/m
Direct measurement method PN-T-06580-3:2002 | PB-01 test procedure issue 1 of 24.09.2018 | PB-02 test procedure issue 3 of 04.01.2022
17 Workplace environment − electromagnetic field from radiocommunication and anti-theft systems: - hand-held and cordless radiotelephones, short-range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) - anti-theft and electronic article surveillance systems Magnetic field strength:
in the frequency range from 27 MHz up to 1 GHz Range (0,01 – 2) A/m
Direct measurement method PN-T-06580-3:2002 | PB-01 test procedure issue 1 of 24.09.2018 | PB-02 test procedure issue 3 of 04.01.2022
18 Workplace environment − electromagnetic field from radiocommunication and anti-theft systems: - hand-held and cordless radiotelephones, short-range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) - anti-theft and electronic article surveillance systems Magnetic field strength:
in the frequency range from 1 GHz up to 3 GHz (calculated)
PN-T-06580-3:2002 | PB-01 test procedure issue 1 of 24.09.2018 | PB-02 test procedure issue 3 of 04.01.2022
19 Workplace environment − electromagnetic field originating from equipment used in medical technology: - physiotherapeutic diathermy - magnetic resonance scanners Magnetic flux density:
in the frequency range 0 Hz Range 100 μT − 1000 mT
Direct measurement method PN-T-06580-3:2002 | PB-01 test procedure issue 1 of 24.09.2018 | PB-02 test procedure issue 3 of 04.01.2022
20 Workplace environment − electromagnetic field originating from equipment used in medical technology: - physiotherapeutic diathermy - magnetic resonance scanners Electric field strength:
in the frequency range from 27 MHz up to 3 GHz Range (0,5 − 300) V/m
Direct measurement method PN-T-06580-3:2002 | PB-01 test procedure issue 1 of 24.09.2018 | PB-02 test procedure issue 3 of 04.01.2022
21 Workplace environment − electromagnetic field originating from equipment used in medical technology: - physiotherapeutic diathermy - magnetic resonance scanners Magnetic field strength:
in the frequency range from 27 MHz up to 1 GHz Range (0,01 – 2) A/m
Direct measurement method PN-T-06580-3:2002 | PB-01 test procedure issue 1 of 24.09.2018 | PB-02 test procedure issue 3 of 04.01.2022
22 Workplace environment − electromagnetic field originating from equipment used in medical technology: - physiotherapeutic diathermy - magnetic resonance scanners Magnetic field strength:
in the frequency range from 1 GHz up to 3 GHz (calculated)
PN-T-06580-3:2002 | PB-01 test procedure issue 1 of 24.09.2018 | PB-02 test procedure issue 3 of 04.01.2022

Reference standards (7)

PB-01 test procedure issue 1 of 24.09.2018
PB-02 test procedure issue 3 of 04.01.2022
PN-T-06580-3:2002
Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 151–180
Principles and Methods of Assessing the Working Environment 2017, No. 2 (92), pp. 89–131
Clause 3 of the Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630)
Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630)

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/PL/AB%201709