🇵🇱 GŁÓWNY INSPEKTORAT OCHRONY ŚRODOWISKA PL

PCA AB 165 • Warszawa, Poland • 121 methods

Water & wastewaterEnvironment

GŁÓWNY INSPEKTORAT OCHRONY ŚRODOWISKA is a laboratory accredited by PCA under number AB 165 (Warszawa, Poland). Its accreditation scope covers 121 test methods in the following areas: Water & wastewater, Environment. Test objects include: Water, wastewater, Water, Waste gases, Sewage sludge. Most frequently used techniques: Spectrophotometric method, Titrimetric method, Gravimetric method.

At a glance

  • Accreditation number: PCA AB 165
  • Methods in scope: 121
  • Types of test objects: 13
  • Techniques used: 26
  • City: Warszawa, Poland
Accreditation number
AB 165
Accreditation body
PCA
Address
ul. Chmielna 132/134, 00-805 Warszawa, CENTRALNE LABORATORIUM BADAWCZE, ODDZIAŁ W BIAŁYMSTOKU
City
Warszawa, Poland

What this laboratory tests (13)

Analytical techniques used (26)

Laboratory sections (4)

Laboratory locations

Certificate information

Issue date
15.06.2026
Issue no.
27

Accreditation scope — test methods (121)

No. Test object Methodology / Parameters Technique Reference document
Laboratory in Białystok
1 Water, wastewater Total suspended solids (TSS)
Range (5,0 – 1200) mg/l
Gravimetric method PN-EN 872:2007+Ap1:2007
2 Water, wastewater Dissolved solids concentration
Range (50 – 3500) mg/l
Gravimetric method PN-EN 15216:2022-03
3 Water, wastewater Orthophosphate concentration
Range (0,020 – 50) mg/l PO4 Range (0,007 – 16) mg/l P-PO4
Spectrophotometric method PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010
4 Water, wastewater Total phosphorus concentration
Range (0,020 – 20) mg/l P
Spectrophotometric method PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010
5 Water, wastewater Nitrite nitrogen concentration
Range (0,002 – 5) mg/l N-NO2 Range (0,007 – 15) mg/l NO2
Spectrophotometric method PN-EN 26777:1999
6 Water, wastewater Ammonium nitrogen concentration
Range (0,50 – 200) mg/l N-NH4 Range (0,65 – 250) mg/l NH4
Titrimetric method PN-ISO 5664:2002
7 Water, wastewater Kjeldahl nitrogen concentration
Range (0,50 – 200) mg/l N
Titrimetric method PN-EN 25663:2001
8 Water, wastewater Total nitrogen concentration (calculated) PB-26/CLB issue 1 of 16.01.2026
9 Water, wastewater Total alkalinity
Range (10 – 1000) mg/l CaCO3 Range (0,2 – 20,0) mmol/l
Titrimetric method PN-EN ISO 9963-1:2001+Ap1:2004
10 Water, wastewater Dissolved oxygen concentration
Range (0,2 – 20,0) mg/l O2
Electrochemical method PN-EN ISO 5814:2013-04
11 Water, wastewater Biochemical oxygen demand – BOD5
Range (0,5 – 6,0) mg/l O2
Electrochemical method PN-EN 1899-2:2002
12 Water, wastewater Biochemical oxygen demand BOD5
Range (3,0 – 6000) mg/l O2
Electrochemical method PN-EN ISO 5815-1:2019-12
13 Water, wastewater Chemical oxygen demand - COD-Cr
Range (6,0 – 10000) mg/l O2
Spectrophotometric method PN-ISO 15705:2005
14 Water, wastewater Element concentrations:
Aluminium (10 – 5000) μg/l Arsenic (1,0 – 5000) μg/l Boron (10 – 2000) μg/l Barium (10 – 5000) μg/l Cadmium (0,020 – 5000) μg/l Total chromium (10 – 5000) μg/l Copper (3,0 – 5000) μg/l Total iron (10 – 20000) μg/l Manganese (10,0 – 20000) μg/l Molybdenum (3,0 – 2000) μg/l Vanadium (3,0 – 2000) μg/l Antimony (0,5 – 1000) μg/l Nickel (1,0 – 5000) μg/l Lead (0,30 – 5000) μg/l Zinc (15 – 5000) μg/l Cobalt (10 – 5000) μg/l Silver (0,75 – 2000) μg/l Beryllium (0,10 – 2000) μg/l Selenium (5,0 – 2000) μg/l Tin (10 – 2000) μg/l Thallium (0,5 – 2000) μg/l Titanium (10 – 2000) μg/l Sodium (0,10 – 900) mg/l Potassium (0,20 – 200) mg/l Calcium (2,0 – 500) mg/l Magnesium (0,40 – 200) mg/l
Inductively coupled plasma mass spectrometry (ICP-MS) PN-EN ISO 17294-2:2024-04
15 Water, wastewater Anion concentrations
Chlorides (2,0 – 1000) mg/l Sulfates (5,0 – 500) mg/l
Ion chromatography with conductometric detection (IC-CD) PN-EN ISO 10304-1:2009+AC:2012
16 Water, wastewater Total phosphorus concentration
Range (0,015 – 100) mg/l
Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN ISO 11885:2009
17 Water, wastewater Nitrate nitrogen and nitrite nitrogen concentration (sum)
Range (0,10 – 100) mg/l
Continuous flow analysis (CFA) with spectrophotometric detection PN-EN ISO 13395:2001
18 Water, wastewater Nitrite nitrogen concentration
Range (0,0020 – 4,0) mg/l N-NO2
Continuous flow analysis (CFA) with spectrophotometric detection PN-EN ISO 13395:2001
19 Water, wastewater Nitrate nitrogen concentration (calculated) PN-EN ISO 13395:2001
20 Water, wastewater Nitrate concentration (calculated) PN-EN ISO 13395:2001
21 Water, wastewater Nitrite concentration (calculated) PN-EN ISO 13395:2001
22 Water Colour
Range (5 – 200) mg/l Pt
Spectrophotometric method PN-EN ISO 7887:2012 + Ap1:2015-06 Method C
23 Water Permanganate index
Range (0,5 – 80) mg/l O2
Titrimetric method PN-EN ISO 8467:2001
24 Water Mercury concentration
Range (0,0200 – 10,0) ug/l
Atomic fluorescence spectrometry (AFS) PN-EN ISO 17852:2009
25 Water Nitrate nitrogen concentration
Range (0,50 – 100) mg/l
Ion chromatography with conductometric detection (IC-CD) PN-EN ISO 10304-1:2009+AC:2012
26 Water Nitrate concentration
Range (2,5 – 440) mg/l
Ion chromatography with conductometric detection (IC-CD) PN-EN ISO 10304-1:2009+AC:2012
27 Wastewater Element concentrations:
Aluminium (0,050 – 2,00) mg/l Cobalt (0,0100 – 2,00) mg/l Chromium (0,0100 – 5,0) mg/l Copper (0,0100 – 20,0) mg/l Iron (0,050 – 40,0) mg/l Lead (0,0100 – 5,0) mg/l Zinc (0,0300 – 40,0) mg/l
Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN ISO 11885:2009
28 Wastewater Mercury concentration
Range (0,0100 – 5,0) mg/l
Atomic absorption spectrometry with amalgamation technique PB-03/BI issue 4 of 10.01.2021
29 Soil pH - in H2O
Range 4,0 – 10,0
Potentiometric method PN-EN ISO 10390:2022-09
30 Soil pH - in KCl
Range 4,0 – 10,0
Potentiometric method PN-EN ISO 10390:2022-09
31 Soil Element content
Arsenic (10,0 – 500) mg/kg Barium (10,0 – 3000) mg/kg Cadmium (1,00 – 400) mg/kg Total chromium (10,0 – 1500) mg/kg Copper (10,0 – 1000) mg/kg Molybdenum (10,0 – 260) mg/kg Cobalt (10,0 – 300) mg/kg Nickel (10,0 – 600) mg/kg Lead (10,0 – 1000) mg/kg Zinc (10,0 – 3000) mg/kg Tin (10,0 – 500) mg/kg
Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN ISO 22036:2024-07
32 Soil Mercury content
Range (0,300 – 30,0) mg/kg
Atomic absorption spectrometry with amalgamation technique PB-03/BI issue 4 of 10.01.2021
33 Sewage sludge pH - in H2O
Range 4,0 – 10,0
Potentiometric method PN-EN ISO 10390:2022-09
34 Sewage sludge Element content:
Cadmium (1,00 – 350) mg/kg Total chromium (10,0 – 2500) mg/kg Copper (10,0 – 2000) mg/kg Nickel (10,0 – 500) mg/kg Lead (10,0 – 1500) mg/kg Zinc (10,0 – 5000) mg/kg Calcium (0,10 – 20) % Calcium (1,0 – 200) g/kg Magnesium (0,010 – 5,0) % Magnesium (0,10 – 50) g/kg Total phosphorus (0,10 – 4,0) % Total phosphorus (1,0 – 40) g/kg
Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN ISO 22036:2024-07
35 Sewage sludge Mercury content
Range (0,70 – 25,0) mg/kg
Atomic absorption spectrometry with amalgamation technique PB-03/BI issue 4 of 10.01.2021
Field Laboratory
36 Water Sampling for chemical and physical testing PN-EN ISO 5667-6:2016-12
37 Water Temperature
Range (0,1 – 35) ºC
PN-77/C-04584
38 Water Sampling for chemical and physical testing PN- ISO 5667-4:2017-10
39 Water Temperature
Range (0,1 – 35) ºC
PN-77/C-04584
40 Water Sampling for chemical and physical testing PN-ISO 5667-11:2017-10 excluding cl. 6.3
41 Water Temperature
Range (0,1 – 35) ºC
PN-77/C-04584
42 Wastewater Sampling for chemical and physical testing Manual/automatic method PN-ISO 5667-10:2021-11
43 Wastewater Temperature
Range (0,1 – 35) ºC
PN-77/C-04584
44 Water, wastewater Dissolved oxygen concentration
Range (0,3 – 20) mg/l O2
Electrochemical method PN-EN ISO 5814:2013-04
45 Water, wastewater Dissolved oxygen concentration
Range (0,3 – 20) mg/l O2
Optical method ISO 17289:2014
46 Water, wastewater pH
Range 4,0 – 10,0
Potentiometric method PN-EN ISO 10523:2012
47 Water, wastewater Electrical conductivity
Range (100 – 10000) μS/cm
Conductometric method PN-EN 27888:1999
48 Soil Sampling for chemical and physical testing PN-ISO 10381-4:2007 excluding cl. 8 | PN-ISO 10381-5:2009
49 Sewage sludge Sampling for chemical, biological and physical testing PN-EN ISO 5667-13:2011
50 General environment - noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level
Range (24 – 135) dB
Direct measurement method Annex 7 to the Regulation of the Minister of Climate and Environment of 7.09.2021 (consolidated text Journal of Laws of 2023, item 1706) excluding cl. F
51 General environment - noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Annex 7 to the Regulation of the Minister of Climate and Environment of 7.09.2021 (consolidated text Journal of Laws of 2023, item 1706) excluding cl. F
52 General environment - noise from roads, railway lines, tram lines A-weighted equivalent sound pressure level
Range (24 – 135) dB
Direct measurement method Annex 3 to the Regulation of the Minister of the Environment of 16.06.2011 (Journal of Laws 2011 No. 140, item 824) excluding cl. H (Journal of Laws 2011 No. 288, item 1697)
53 General environment - noise from roads, railway lines, tram lines A-weighted sound exposure level
Range (24 – 135) dB
Direct measurement method Annex 3 to the Regulation of the Minister of the Environment of 16.06.2011 (Journal of Laws 2011 No. 140, item 824) excluding cl. H (Journal of Laws 2011 No. 288, item 1697)
54 General environment - noise from roads, railway lines, tram lines A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Annex 3 to the Regulation of the Minister of the Environment of 16.06.2011 (Journal of Laws 2011 No. 140, item 824) excluding cl. H (Journal of Laws 2011 No. 288, item 1697)
55 Environment – electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) Electric field strength:
in the frequency range from 200 kHz to 3 GHz. (0,2 – 300) V/m in the frequency range from 80 MHz to 60 GHz. (0,8 – 300) V/m
Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the legally regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Direct measurement method Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630)
56 Environment – electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) Magnetic field strength (calculated)
in the frequency range from 10 MHz to 60 GHz
Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the legally regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Clause 3 of the Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630)
57 Waste gases Concentration of oxygen, nitrogen oxides, carbon monoxide, sulphur dioxide, carbon dioxide
O2 (1,5 – 21,0) % NOx (2 – 1025) mg/m3 CO (7 – 1250) mg/m3 SO2 (5 – 1430) mg/m3 CO2 (0,3 – 20,0) %
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the legally regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Paramagnetic method; Chemiluminescence method; Non-dispersive infrared spectrometry method (NDIR) PN-ISO 10396:2001
58 Waste gases Emission of CO, SO2, NOx (NO and NO2 expressed as NO2) (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the legally regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
PN-ISO 10396:2001
59 Waste gases Concentration of organic substances in the form of gases and vapours expressed as total gaseous organic carbon
Range (5 – 1000) mg/m3
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the legally regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Continuous flame ionization detection method (FID) PN-EN 12619:2013-05
60 Waste gases Emission of organic substances in gaseous and vapour form expressed as total gaseous organic carbon (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the legally regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
PN-EN 12619:2013-05
61 Waste gases Gas volume flow rate for dynamic pressures > 10 Pa
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the legally regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Stagnation pressure method PN-Z-04030-7:1994
62 Waste gases Velocity
Range (1,5 – 6,0) m/s
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the legally regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Anemometric method PN-Z-04030-7:1994
63 Waste gases Sampling for determination of dust concentration
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the legally regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
PN-Z-04030-7:1994
64 Waste gases Dust concentration
Range (1 – 1000) mg/m3
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the legally regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Gravimetric method PN-Z-04030-7:1994
65 Waste gases Dust emission (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the legally regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
PN-Z-04030-7:1994
66 Waste gases Sampling for the determination of the concentration of individual gaseous organic compounds
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the legally regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
PN-EN 13649:2005
67 Waste gases Emission of individual gaseous organic compounds (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the legally regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
PN-EN 13649:2005
68 Waste gases Sampling for determination of concentrations of organic compounds
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the legally regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Aspiration method using activated carbon/silica gel PN-Z-04008-4:1999
69 Waste gases Emission of organic compounds (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the legally regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
PN-Z-04008-4:1999
Laboratory in Łomża
70 Water, wastewater Chloride concentration
Range (5,0 – 400) mg/l
Titrimetric method PN-ISO 9297:1994
71 Water, wastewater Total suspended solids (TSS)
Range (5,0 – 1200) mg/l
Gravimetric method PN-EN 872:2007+Ap1:2007
72 Water, wastewater Biochemical oxygen demand - BOD5
Range (0,5 – 6,0) mg/l O2
Electrochemical method PN-EN 1899-2:2002
73 Water, wastewater Biochemical oxygen demand - BOD5
Range (5 – 3000) mg/l O2
Electrochemical method PN-EN ISO 5815-1:2019-12
74 Water, wastewater Dissolved oxygen concentration
Range (0,1 – 20,0) mg/l O2
Electrochemical method PN-EN ISO 5814:2013-04
75 Water, wastewater Chemical oxygen demand - COD-Cr
Range (6,0 – 7000) mg/l O2
Spectrophotometric method PN-ISO 15705:2005
76 Water, wastewater Dissolved solids concentration
Range (50,0 – 3500) mg/l
Gravimetric method PN-EN 15216:2022-03
77 Water, wastewater Total organic carbon concentration
Range (2,0 – 1000) mg/l
High-temperature combustion with IR detection PN-EN 1484:1999
78 Water, wastewater Sulfate concentration
Range (10,0 – 200) mg/l
Gravimetric method PN-ISO 9280:2002
79 Water, wastewater Total alkalinity
Range (25,0 – 500) mg/l CaCO3 Range (0,5 – 10) mmol/l
Titrimetric method PN-EN ISO 9963-1:2001+Ap1:2004
80 Water, wastewater Ammonium nitrogen concentration
Range (0,50 – 200) mg/l
Titrimetric method PN-ISO 5664:2002
81 Water, wastewater Nitrate nitrogen concentration
Range (0,02 – 20) mg/l NNO3 Range (0,1 – 90) mg/l NO3
Spectrophotometric method PN-82/C-04576/08
82 Water, wastewater Nitrite nitrogen concentration
Range (0,003 – 2,0) mg/l NNO2 Range (0,01 – 6,5) mg/l NO2
Spectrophotometric method PN-EN 26777:1999
83 Water, wastewater Orthophosphate concentration
Range (0,020 – 10) mg/l PO4 Range (0,0065 – 3,2) mg/l P-PO4
Spectrophotometric method PN-EN ISO 6878:2006 +Ap1:2010 +Ap2:2010
84 Water, wastewater Total phosphorus concentration
Range (0,020 – 50,0) mg/l
Spectrophotometric method PN-EN ISO 6878:2006 +Ap1:2010 +Ap2:2010
85 Water, wastewater Kjeldahl nitrogen concentration
Range (0,50 – 200) mg/l
Titrimetric method PN-EN 25663:2001
86 Water, wastewater Total nitrogen concentration (calculated) PB-26/CLB issue 1 of 16.01.2026
87 Water, wastewater Mineral oil index
Range (0,10 – 50) mg/l
Gas chromatography with flame ionization detection (GC-FID) PN-EN ISO 9377-2:2003
88 Water Permanganate index
Range (0,4 – 80) mg/l O2
Titrimetric method PN-EN ISO 8467:2001
89 Soil pH - in H2O
Range 4,0 – 10,0
Potentiometric method PN-EN ISO 10390:2022-09
90 Soil pH - in KCl
Range 4,0 – 10,0
Potentiometric method PN-EN ISO 10390:2022-09
91 Soil Content of hydrocarbons C10 - C40
Range (30 – 10000) mg/kg
Gas chromatography with flame ionization detection (GC-FID) PN-EN ISO 16703:2011
92 Soil Sum of hydrocarbons C12 - C35 of oil fraction components
Range (30 – 10000) mg/kg
Gas chromatography with flame ionization detection (GC-FID) PN-EN ISO 16703:2011
93 Sewage sludge Dry residue content
Range (0,50 – 90,0) %
Gravimetric method PN-EN ISO 11465:2026-03 Method A
94 Sewage sludge Loss on ignition of dry matter (LOI)
Range (10,0 – 90,0) %
Gravimetric method PN-EN 15935:2022-01
95 Sewage sludge pH - in H2O
Range 4,0 – 10,0
Potentiometric method PN-EN ISO 10390:2022-09
96 Sewage sludge Total phosphorus content
Range (0,40 – 150) g/kg Range (0,040 – 15) %
Spectrophotometric method PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 | PN-EN 13346:2002
97 Sewage sludge Kjeldahl nitrogen content
Range (0,25 – 10,0) %
Titrimetric method PN-EN 13342:2002
98 Sewage sludge Ammonium nitrogen content
Range (0,10 – 3,0) %
Spectrophotometric method PB-08/BI issue 3 of 15.05.2020
Laboratory in Suwałki
99 Water Total alkalinity
Range (0,14 – 18,0) mmol/l
Titrimetric method PN-EN ISO 9963-1:2001+Ap1:2004
100 Water Colour
Range (5 – 200) mg/l Pt
Spectrophotometric method PN-EN ISO 7887:2012+Ap.1:2015-06 Method C
101 Water, wastewater Dissolved oxygen concentration
Range (0,20 – 20) mg/l O2
Optical method ISO 17289:2014
102 Water, wastewater Biochemical oxygen demand - BOD5
Range (0,5 – 6,0) mg/l O2
Optical method PN-EN 1899-2:2002 excluding cl. 7.2 | ISO 17289:2014
103 Water, wastewater Biochemical oxygen demand - BOD5
Range (3,0 – 6000) mg/l O2
Optical method PN-EN ISO 5815-1:2019-12
104 Water, wastewater Permanganate index
Range (0,4 – 100) mg/l O2
Titrimetric method PN-EN ISO 8467:2001
105 Water, wastewater Total suspended solids (TSS)
Range (5,0 – 1200) mg/l
Gravimetric method PN-EN 872:2007+Ap1:2007
106 Water, wastewater Kjeldahl nitrogen concentration
Range (0,50 – 200) mg/l
Titrimetric method PN-EN 25663:2001
107 Water, wastewater Total nitrogen concentration (calculated) PB-26/CLB issue 1 of 16.01.2026
108 Water, wastewater Nitrite nitrogen concentration
Range (0,0010 – 5,0) mg/l N-NO2 Range (0,0030 – 17,0) mg/l NO2
Spectrophotometric method PN-EN 26777:1999
109 Water, wastewater Total phosphorus concentration
Range (0,020 – 50,0) mg/l
Spectrophotometric method PN-EN ISO 6878:2006+Ap1:2010+ Ap2:2010
110 Water, wastewater Orthophosphate concentration
Range (0,020 – 10) mg/l PO4
Spectrophotometric method PN-EN ISO 6878:2006+Ap1:2010+ Ap2:2010
111 Water, wastewater Chemical oxygen demand - COD-Cr
Range (6,0 – 2000) mg/l
Spectrophotometric method PN-ISO 15705:2005
112 Water, wastewater Ammonium nitrogen concentration
Range (0,50 – 200) mg/l
Titrimetric method PN-ISO 5664:2002
113 Water, wastewater Concentration of total organic carbon (TOC and DOC)
Range (2,0 – 1000) mg/l
High-temperature combustion with IR detection PN-EN 1484:1999
114 Water, wastewater Nitrate nitrogen concentration
Range (0,01 – 50,0) mg/l N-NO3 Range (0,04 – 221) mg/l NO3
Spectrophotometric method PN-82/C-04576.08
115 Water, wastewater, soil Identification of organic compounds Gas chromatography with mass spectrometry detection (GC-MS) using the NIST 14 mass spectral library PB-17/BI issue 5 of 25.05.2023
116 Water, wastewater E PAH concentration
Regulated area: E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is not made publicly available by the accredited body.
High-performance liquid chromatography with fluorescence detection (HPLC-FLD) PN-EN ISO 17993
117 Water, wastewater E Volatile organic compound (VOC) concentration
Regulated area: E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is not made publicly available by the accredited body.
Gas chromatography with purge and trap technique (Purge&Trap) and mass spectrometry detection (P&T GC-MS) PN-EN ISO 15680
118 Water E Pesticide concentration
Regulated area: E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is not made publicly available by the accredited body.
Gas chromatography with mass spectrometry detection (GC-MS) EPA 525.3
119 Water E Alkylphenol concentration
Regulated area: E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is not made publicly available by the accredited body.
Gas chromatography with mass spectrometry detection (GC-MS) PN-EN ISO 18857-1
120 Soil E Content of polycyclic aromatic hydrocarbons
Regulated area: E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is not made publicly available by the accredited body.
High-performance liquid chromatography with fluorescence detection (HPLC-FLD) PN-ISO 13877 | PN-EN 17503
121 Soil E Polychlorinated biphenyl content
Regulated area: E – Flexible scope of accreditation. The flexibility of the scope covers the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. The list of activities performed within the flexible scope of accreditation is not made publicly available by the accredited body.
Gas chromatography with mass spectrometry detection (GC-MS) PN-ISO 10382 | PN-EN 17322

Reference standards (69)

EPA 525.3
ISO 17289:2014
PB-03/BI issue 4 of 10.01.2021
PB-08/BI issue 3 of 15.05.2020
PB-17/BI issue 5 of 25.05.2023
PB-26/CLB issue 1 of 16.01.2026
PB-26/CLB issue 1 of 16.01.2026
PN- ISO 5667-4:2017-10
PN-77/C-04584
PN-82/C-04576.08
PN-82/C-04576/08
PN-EN 12619:2013-05
PN-EN 13342:2002
PN-EN 13346:2002
PN-EN 13649:2005
PN-EN 1484:1999
PN-EN 15216:2022-03
PN-EN 15935:2022-01
PN-EN 17322
PN-EN 17503
PN-EN 1899-2:2002
PN-EN 1899-2:2002 excluding cl. 7.2
PN-EN 25663:2001
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10304-1:2009+AC:2012
PN-EN ISO 10390:2022-09
PN-EN ISO 10523:2012
PN-EN ISO 11465:2026-03 Method A
PN-EN ISO 11885:2009
PN-EN ISO 13395:2001
PN-EN ISO 15680
PN-EN ISO 16703:2011
PN-EN ISO 17294-2:2024-04
PN-EN ISO 17852:2009
PN-EN ISO 17993
PN-EN ISO 18857-1
PN-EN ISO 22036:2024-07
PN-EN ISO 5667-13:2011
PN-EN ISO 5667-6:2016-12
PN-EN ISO 5814:2013-04
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6878:2006 +Ap1:2010 +Ap2:2010
PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010
PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010
PN-EN ISO 6878:2006+Ap1:2010+ Ap2:2010
PN-EN ISO 7887:2012 + Ap1:2015-06 Method C
PN-EN ISO 7887:2012+Ap.1:2015-06 Method C
PN-EN ISO 8467:2001
PN-EN ISO 9377-2:2003
PN-EN ISO 9963-1:2001+Ap1:2004
PN-ISO 10381-4:2007 excluding cl. 8
PN-ISO 10381-5:2009
PN-ISO 10382
PN-ISO 10396:2001
PN-ISO 13877
PN-ISO 15705:2005
PN-ISO 5664:2002
PN-ISO 5667-10:2021-11
PN-ISO 5667-11:2017-10 excluding cl. 6.3
PN-ISO 9280:2002
PN-ISO 9297:1994
PN-Z-04008-4:1999
PN-Z-04030-7:1994
Clause 3 of the Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630)
Annex 3 to the Regulation of the Minister of the Environment of 16.06.2011 (Journal of Laws 2011 No. 140, item 824) excluding cl. H (Journal of Laws 2011 No. 288, item 1697)
Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630)
Annex 7 to the Regulation of the Minister of Climate and Environment of 7.09.2021 (consolidated text Journal of Laws of 2023, item 1706) excluding cl. F

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/PL/AB%20165