🇵🇱 ENVILAB-EKO Norbert Dąbrowski PL
EnvironmentMaterials & polymers
ENVILAB-EKO Norbert Dąbrowski is a laboratory accredited by PCA under number AB 1642 (Wrocław, Poland). Its accreditation scope covers 325 test methods in the following areas: Environment, Materials & polymers. Test objects include: Waste gases, Workplace environment − air − air samples collected on solid sorbent, Workplace environment − air − air samples collected on filters, Workplace environment − air − air samples collected into absorbing…. Most frequently used techniques: Gas chromatography with flame ionization detection (GC-FID), Flame atomic absorption spectrometry (FAAS), Spectrophotometric method.
At a glance
- Accreditation number: PCA AB 1642
- Methods in scope: 325
- Types of test objects: 27
- Techniques used: 24
- City: Wrocław, Poland
- Accreditation number
- AB 1642
- Accreditation body
- PCA
- Address
- ul. bp. Bernarda Bogedaina 3, 50-514 Wrocław
- City
- Wrocław, Poland
What this laboratory tests (27)
- Waste gases — 140 methods
- Workplace environment − air − air samples collected on solid sorbent — 83 methods
- Workplace environment − air − air samples collected on filters — 30 methods
- Workplace environment − air − air samples collected into absorbing solutions — 13 methods
- Workplace environment − non-laser optical radiation — 12 methods
- Workplace environment − air — 7 methods
- Workplace environment - electromagnetic field — 4 methods
- Workplace environment − emergency lighting — 3 methods
- General environment – noise from installations, equipment and industrial plants — 2 methods
- Rooms in residential, collective residence and public utility buildings − noise — 2 methods
- Rooms intended for human occupancy: – air – air samples collected on sorbent tubes — 2 methods
- Workplace environment - electromagnetic field in the work space originating from power systems and AC electrical supply installations in the power industry — 2 methods
- Workplace environment - energy expenditure — 2 methods
- Workplace environment - hand-arm vibration — 2 methods
- Workplace environment - moderate microclimate — 2 methods
- and 12 more
Analytical techniques used (24)
- Gas chromatography with flame ionization detection (GC-FID) — 154 methods
- Flame atomic absorption spectrometry (FAAS) — 25 methods
- Spectrophotometric method — 22 methods
- Direct measurement method — 20 methods
- Fourier transform infrared spectrometry (FT-IR) — 4 methods
- Gravimetric method — 4 methods
- Non-dispersive infrared spectrometry (NDIR) — 4 methods
- Chemiluminescence method (CLD) — 2 methods
- Electrochemical method — 2 methods
- Paramagnetic method (PMD) — 2 methods
- Anemometric method — 1 method
- Calculation method — 1 method
- Condensation-adsorption method — 1 method
- Continuous flame ionization detection method (FID) — 1 method
- Differential pressure measurement method — 1 method
- and 9 more
Certificate information
- Issue date
- 28.07.2026
- Issue no.
- 23
Accreditation scope — test methods (325)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Workplace environment − air | Sampling for the assessment of occupational exposure to: − dust agents inhalable fraction respirable fraction − metals and their compounds, including inhalable fraction respirable fraction − organic substances, including inhalable fraction − inorganic substances, including inhalable fraction thoracic fraction respirable fraction − respirable man-made mineral fibres − respirable asbestos fibres |
Personal dosimetry method | PN-Z-04008-7:2002+Az1:2004 | |
| 2 | Workplace environment − air | Sampling for the assessment of occupational exposure to: − organic substances − inorganic substances, including inhalable fraction |
Stationary method | PN-Z-04008-7:2002+Az1:2004 | |
| 3 | Workplace environment − air | Exposure index (calculated) | PN-Z-04008-7:2002+Az1:2004 | ||
| 4 | Workplace environment − air | Concentration of harmful dust agents – inhalable fraction apatites and phosphorites petroleum bitumen portland cement titanium dioxide natural graphite synthetic graphite kaolin amorphous and synthetic silica wood dusts flour dusts dusts not classified according to toxicity organic dusts of animal and plant origin, excluding wood and flour dusts carbon black calcium sulfate (VI) (gypsum) talc coal (hard, brown) calcium magnesium carbonate (dolomite) silicon carbide, non-fibrous Range (0,10 – 17,0) mg/m3 |
Gravimetric method | PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08 | |
| 5 | Workplace environment − air | Concentration of harmful dust agents – respirable fraction apatites and phosphorites portland cement natural graphite amorphous and synthetic silica organic dusts of animal and plant origin, excluding wood and flour dusts diesel engine exhaust talc coal (hard, brown) Range (0,09 – 15,4) mg/m3 |
Gravimetric method | PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08 | |
| 6 | Workplace environment − air | Gas concentrations: CO (2,5 – 117) mg/m3 Range (2,0 – 100) ppm NO (0,13 – 6,25) mg/m3 (0,1 – 5,0) ppm NO2 (0,19 – 2,3) mg/m3 (0,1 – 1,2) ppm |
Electrochemical method | EV-PB-1 issue 2 of 01.04.2021 | |
| 7 | Workplace environment − air | Carbon dioxide concentration Range (900 - 36000) mg/m3 |
Electrochemical method | EV-PB-12 issue 2 of 22.02.2022 | |
| 8 | Workplace environment − noise | A-weighted equivalent sound level Maximum A-weighted sound level Range (30 - 135) dB C-weighted peak sound pressure level Range (40 - 137) dB |
Direct measurement method | PN-N-01307:1994 | PN-EN ISO 9612:2025-11 excluding the methods covering strategies 2 and 3 – cl. 10 and 11 | |
| 9 | Workplace environment − noise | Noise exposure level referred to: an 8-hour daily working time the average weekly working time (calculated) |
PN-N-01307:1994 | PN-EN ISO 9612:2025-11 excluding the methods covering strategies 2 and 3 – cl. 10 and 11 | ||
| 10 | Workplace environment – ultrasonic noise | Equivalent sound pressure levels in one-third octave bands with centre frequencies from 10 kHz to 40 kHz Maximum sound pressure levels in one-third octave bands with centre frequencies from 10 kHz to 40 kHz Range (49 - 158) dB |
Direct measurement method | PN-Z-01339:2020-12 | |
| 11 | Workplace environment – ultrasonic noise | Equivalent sound pressure levels in third-octave bands with centre frequencies from 10 kHz to 40 kHz referred to: an 8-hour daily working time the average weekly working time (calculated) |
PN-Z-01339:2020-12 | ||
| 12 | Rooms in residential, collective residence and public utility buildings − noise | A-weighted equivalent sound level Maximum A-weighted sound level Range (22 – 135) dB |
Direct measurement method | PN-87/B-02156 | |
| 13 | Rooms in residential, collective residence and public utility buildings − noise | A-weighted equivalent sound level for reference time T (calculated) | PN-87/B-02156 | ||
| 14 | General environment – noise from installations, equipment and industrial plants | A-weighted equivalent sound pressure level Range (25 - 135) dB |
Direct measurement method | Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 consolidated text Journal of Laws 2023 item 1706 excluding cl. F | |
| 15 | General environment – noise from installations, equipment and industrial plants | A-weighted equivalent sound level over the reference time T expressed by the indicators, LAeqD and LAeqN (calculated) | Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 consolidated text Journal of Laws 2023 item 1706 excluding cl. F | ||
| 16 | Workplace environment - whole-body vibration | Frequency-weighted r.m.s. vibration acceleration Range (0,03 – 10) m/s2 |
Direct measurement method | PN-EN 14253+A1:2011 | |
| 17 | Workplace environment - whole-body vibration | Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the r.m.s. frequency-corrected vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz), Exposure lasting 30 minutes or less, expressed as the r.m.s. frequency-weighted vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz) (calculated) | PN-EN 14253+A1:2011 | ||
| 18 | Workplace environment - hand-arm vibration | Frequency-weighted r.m.s. vibration acceleration Range (0,56 – 60) m/s2 |
Direct measurement method | PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11 | |
| 19 | Workplace environment - hand-arm vibration | Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the vector sum of the r.m.s. frequency-corrected vibration accelerations determined for three directional components (ahwx, ahwy, ahwz), Exposure lasting 30 minutes or less, expressed as the vector sum of the r.m.s. frequency-weighted vibration accelerations determined for three directional components (ahwx, ahwy, ahwz) (calculated) | PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11 | ||
| 20 | Workplace environment − hot microclimate | Air temperature Range (15 - 60) °C Natural wet bulb temperature Range (15 - 60) °C Black globe temperature Range (15 - 60) °C |
Direct measurement method | PN-EN ISO 7243:2018-01 | |
| 21 | Workplace environment − hot microclimate | WBGT index, WBGTeff index (calculated) | PN-EN ISO 7243:2018-01 | ||
| 22 | Workplace environment − cold microclimate | Air temperature Range (- 30,0 - 10,0) °C Black globe temperature Range (- 30,0 - 10,0) °C Air humidity Range (20 - 90) % Air velocity Range (0,15 - 1,0) m/s |
Direct measurement method | PN-EN ISO 11079:2008 | |
| 23 | Workplace environment − cold microclimate | IREQmin index, IREQneutral index, tWC index (calculated) | PN-EN ISO 11079:2008 | ||
| 24 | Workplace environment - moderate microclimate | Air temperature Range (10 - 30) °C Black globe temperature Range (10 - 40) °C Air humidity Range (20 - 90) % Air velocity Range (0,15 - 1,0) m/s |
Direct measurement method | PN-EN ISO 7730:2006 +Ap2:2016-04 | |
| 25 | Workplace environment - moderate microclimate | PMV index, PPD index (calculated) | PN-EN ISO 7730:2006 +Ap2:2016-04 | ||
| 26 | Workplace environment - energy expenditure | Air temperature Range (0 - 40) ̊C Air flow Range (10 - 60) dm3/min |
Direct measurement method | EV-PB-8 issue 3 of 18.05.2021 | |
| 27 | Workplace environment - energy expenditure | Energy expenditure (calculated) | EV-PB-8 issue 3 of 18.05.2021 | ||
| 28 | Workplace environment − indoor electric lighting | Illuminance Range (5 - 10000) lx |
Direct measurement method | PN-83/E-04040.03 EV-PB-2 issue 1 of 02.01.2017 | |
| 29 | Workplace environment − indoor electric lighting | Illuminance uniformity (calculated) | PN-83/E-04040.03 EV-PB-2 issue 1 of 02.01.2017 | ||
| 30 | Workplace environment − outdoor electric lighting | Illuminance Range (0,5 - 10000) lx |
Direct measurement method | PN-83/E-04040.03 | |
| 31 | Workplace environment − outdoor electric lighting | Illuminance uniformity (calculated) | PN-83/E-04040.03 | ||
| 32 | Workplace environment − emergency lighting | Illuminance Range (0,5 - 500) lx |
Direct measurement method | PN-EN 1838:2025-05 excluding clauses: 5.1.3-5.1.9, 5.2.3-5.2.7, 5.3.4-5.3.8, 5.4.2, 6, 7, Method A | |
| 33 | Workplace environment − emergency lighting | Ratio of minimum to maximum illuminance (calculated) | PN-EN 1838:2025-05 excluding clauses: 5.1.3-5.1.9, 5.2.3-5.2.7, 5.3.4-5.3.8, 5.4.2, 6, 7, Method A | ||
| 34 | Workplace environment − emergency lighting | Emergency lighting switch-on time Range (1 - 80) s |
PN-EN 1838:2025-05 excluding clauses: 5.1.3-5.1.9, 5.2.3-5.2.7, 5.3.4-5.3.8, 5.4.2, 6, 7, Method A | ||
| 35 | Workplace environment − non-laser optical radiation | Effective irradiance UVA, UVB and UVC in the spectral range (180 ÷ 400) nm Range (0,10x10-3 – 39,99) W/m2 |
Direct measurement method (method A) | PN-EN 14255-1:2010 | |
| 36 | Workplace environment − non-laser optical radiation | Effective radiant exposure to hazardous ultraviolet in the spectral range (180 ÷ 400) nm (calculated) | PN-EN 14255-1:2010 | ||
| 37 | Workplace environment − non-laser optical radiation | UVA irradiance in the spectral range (315 ÷ 400) nm Range (0,010 – 3,999x103) W/m2 |
Direct measurement method (method M) | PN-EN 14255-1:2010 | |
| 38 | Workplace environment − non-laser optical radiation | Radiant exposure of UVA radiation in the spectral range (315 ÷ 400) nm (calculated) | PN-EN 14255-1:2010 | ||
| 39 | Workplace environment − non-laser optical radiation | Effective irradiance VIS in the spectral range (300÷700) nm Range (1x10-3 – 399,9) |
Direct measurement method (method O) | PN-EN 14255-2:2010 | |
| 40 | Workplace environment − non-laser optical radiation | Effective radiance of VIS radiation in the spectral range (300÷700) nm (calculated) | PN-EN 14255-2:2010 | ||
| 41 | Workplace environment − non-laser optical radiation | Irradiance of VIS, IRA and IRB in the spectral range (380 ÷ 3000) nm Range (1 – 3999) W/m2 |
Direct measurement method (method X) | PN-EN 14255-2:2010 | |
| 42 | Workplace environment − non-laser optical radiation | Radiant exposure for VIS, IRA, IRB in the spectral range (380 ÷ 3000) nm (calculated) | PN-EN 14255-2:2010 | ||
| 43 | Workplace environment − non-laser optical radiation | Effective irradiance for VIS, IRA in the spectral range (380÷1400) nm Range (1x10-3 – 3,999x103) W/m2 |
Direct measurement method | PN-T-05687:2002, cl. 2.5.4 | |
| 44 | Workplace environment − non-laser optical radiation | Effective radiance for, VIS, IRA in the spectral range (380÷1400) nm (calculated) | PN-T-05687:2002, cl. 2.5.4 | ||
| 45 | Workplace environment − non-laser optical radiation | Effective irradiance for IRA in the spectral range (780÷1400) nm Range (1x10-3 – 3,999x103) W/m2 |
Direct measurement method | PN-T-05687:2002, cl. 2.5.4 | |
| 46 | Workplace environment − non-laser optical radiation | Effective radiance for, IRA in the spectral range (780÷1400) nm (calculated) | PN-T-05687:2002, cl. 2.5.4 | ||
| 47 | Workplace environment - electromagnetic field | Electric field strength in the frequency band: 10 Hz – 400 kHz, 1 GHz – 3 GHz Range (1– 350) V/m |
Direct measurement method | PN-T-06580-3:2002 EV-PB-15 issue 1 of 18.12.2023 | |
| 48 | Workplace environment - electromagnetic field | Magnetic field strength in the frequency range: 10Hz - 400kHz Range (4 – 8000) A/m |
Direct measurement method | PN-T-06580-3:2002 EV-PB-15 issue 1 of 18.12.2023 | |
| 49 | Workplace environment - electromagnetic field | Magnetic field strength: in the frequency range from 1 GHz up to 3 GHz (calculated) |
PN-T-06580-3:2002 EV-PB-15 issue 1 of 18.12.2023 | ||
| 50 | Workplace environment - electromagnetic field | Magnetic field strength in the frequency range: 0 Hz Range 4 A/m – 800 kA/m |
Direct measurement method | PN-T-06580-3:2002 EV-PB-15 issue 1 of 18.12.2023 | |
| 51 | Workplace environment - electromagnetic field in the workspace from magnetotherapy devices | Magnetic field strength: in the frequency range 20 Hz – 50 Hz Range (4 – 8000) A/m Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the legally regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (consolidated text: Journal of Laws of 2018, item 331). |
Direct measurement method (simplified) | Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 151–180 | |
| 52 | Workplace environment - electromagnetic field in the work space originating from power systems and AC electrical supply installations in the power industry | Electric field strength in the frequency range: 10 - 400 kHz Range 100 V/m – 50 kV/m Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the legally regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (consolidated text: Journal of Laws of 2018, item 331). |
Direct measurement method | Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 91–150 | |
| 53 | Workplace environment - electromagnetic field in the work space originating from power systems and AC electrical supply installations in the power industry | Magnetic field strength in the frequency range 10 - 400 kHz Range 4 A/m – 800 kA/m Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the legally regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (consolidated text: Journal of Laws of 2018, item 331). |
Direct measurement method | Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 91–150 | |
| 54 | Workplace environment − air − air samples collected into absorbing solutions | Ammonia concentration/content Range (1,2 - 60) mg/m3 Range (0,006 - 0,3) mg in the sample |
Spectrophotometric method | PN-Z-71-Z-04041 | |
| 55 | Workplace environment − air − air samples collected into absorbing solutions | Hydrogen sulphide concentration/content Range (0,5 - 28) mg/m3 Range (0,010 - 0,160) mg in the sample |
Spectrophotometric method | PN-Z-04015-13:1996 | |
| 56 | Workplace environment − air − air samples collected into absorbing solutions | Nitrogen monoxide concentration/content Range (0,29 - 23) mg/m3 Range (0,23 – 18,4) ppm Range (0,0013 - 0,052) mg in the sample |
Spectrophotometric method | PN-04009-11:2008 | |
| 57 | Workplace environment − air − air samples collected into absorbing solutions | Nitrogen dioxide concentration/content Range (0,089 – 7,1) mg/m3 Range (0,05 – 3,7) ppm Range (0,00040 - 0,016) mg in the sample |
Spectrophotometric method | PN-04009-11:2008 | |
| 58 | Workplace environment − air − air samples collected into absorbing solutions | Concentration/content of nitric acid Range (0,120 – 9,7) mg/m3 Range (0,00055 - 0,022) mg in the sample (calculated) |
PN-04009-11:2008 | ||
| 59 | Workplace environment − air − air samples collected into absorbing solutions | Chlorine concentration/content Range (0,065 – 5,0) mg/m3 Range (0,00026 - 0,0050) mg in the sample |
Spectrophotometric method | PN-75/Z-04037/03 | |
| 60 | Workplace environment − air − air samples collected into absorbing solutions | Formaldehyde concentration/content Range (0,13 – 6,6) mg/m3 Range (0,0010 - 0,040) mg in the sample |
Spectrophotometric method | PN-76/Z-04045/02 | |
| 61 | Workplace environment − air − air samples collected into absorbing solutions | Ozone concentration/content Range (0,0150 – 0,450) mg/m3 Range (0,0010 - 0,0180) mg in the sample |
Spectrophotometric method | PN-Z-04007-2:1994 | |
| 62 | Workplace environment − air − air samples collected into absorbing solutions | Concentration/content of tetraphosphorus decaoxide Range (0,050 – 5,0) mg/m3 Range (0,0010 - 0,10) mg in the sample |
Spectrophotometric method | PN-Z-04073-1:2014-08 | |
| 63 | Workplace environment − air − air samples collected into absorbing solutions | Concentration/content of phosphoric acid Range (0,0690 – 6,9) mg/m3 Range (0,00140 - 0,130) mg in the sample (calculated) |
PN-Z-04073-1:2014-08 | ||
| 64 | Workplace environment − air − air samples collected on solid sorbent | Acetone concentration/content Range (0,10 – 2000) mg/m3 Range (0,0010 – 2,4) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-79-Z-04057.01 | |
| 65 | Workplace environment − air − air samples collected on solid sorbent | Concentration/content of xylene – mixture of isomers 1,2; 1,3; 1,4 m-xylene Range (0,0670-600) mg/m3 Range (0,0010 – 3,0) mg in the sample o-xylene Range (0,0670-620) mg/m3 Range (0,0010 – 3,10) mg in the sample p-xylene Range (0,0670-600) mg/m3 Range (0,0010 – 3,00) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-78-Z-04116.01 | |
| 66 | Workplace environment − air − air samples collected on solid sorbent | Sum of contents of xylene – mixture of isomers 1,2; 1,3; 1,4 (calculated) Range (0,0670-1820) mg/m3 Range (0,0010 – 9,10) mg in the sample |
PN-78-Z-04116.01 | ||
| 67 | Workplace environment − air − air samples collected on solid sorbent | Ethanol concentration/content Range (0,050–4537) mg/m3 Range (0,0010 – 16,3) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | EV-PB-4 issue 1 of 02.01.2017 | |
| 68 | Workplace environment − air − air samples collected on solid sorbent | Butan-1-ol concentration/content Range (0,050 – 569) mg/m3 Range (0,0010 – 4,10) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-89/Z-04023/02 | |
| 69 | Workplace environment − air − air samples collected on solid sorbent | Concentration / content of 2-methylpropan-1-ol Range (0,139 – 1708) mg/m3 Range (0,001 – 4,10) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-86-Z-04155/02 | |
| 70 | Workplace environment − air − air samples collected on solid sorbent | Ethyl acetate concentration/content Range (0,0670-2441) mg/m3 Range (0,02 – 667) ppm Range (0,0010-12,20) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-78-Z-04119/01 | |
| 71 | Workplace environment − air − air samples collected on solid sorbent | Concentration/content of n-butyl acetate Range (0,0670-1138) mg/m3 Range (0,0010-4,10) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-78-Z-04119/01 | |
| 72 | Workplace environment − air − air samples collected on solid sorbent | Toluene concentration/content Range (0,050-569) mg/m3 Range (0,0010-4,10) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | Principles and Methods of Assessing the Working Environment 2011, No. 1 (67), pp. 35–44 | |
| 73 | Workplace environment − air − air samples collected on solid sorbent | 2-butoxyethanol concentration/content Range (0,050-569) mg/m3 Range (0,0010-4,10) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | EV-PB-4 issue 1 of 02.01.2017 | PN-Z-04023-02:1998 | |
| 74 | Workplace environment − air − air samples collected on solid sorbent | Benzene concentration/content Range (0,050-333) mg/m3 Range (0,015 – 102,7) ppm Range (0,0010-2,40) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04016-10:2005 | |
| 75 | Workplace environment − air − air samples collected on solid sorbent | Extraction naphtha concentration/content Range (24,0 - 2083) mg/m3 Range (0,48 - 15) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-81-Z-04134.02 | NIOSH Method 1550, Issue 2, 15 August 1994 | |
| 76 | Workplace environment − air − air samples collected on solid sorbent | White spirit concentration/content Range (16 – 1388) mg/m3 Range (0,32 - 10) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-81-Z-04134.03 | NIOSH Method 1550, Issue 2, 15 August 1994 | |
| 77 | Workplace environment − air − air samples collected on solid sorbent | Styrene concentration/content Range (0,010-569) mg/m3 Range (0,0010-4,10) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-86-Z-04152/02 | |
| 78 | Workplace environment − air − air samples collected on solid sorbent | Methyl methacrylate concentration/content Range (0,10-569) mg/m3 Range (0,0010-4,10) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-92-Z-04113/09 | |
| 79 | Workplace environment − air − air samples collected on solid sorbent | Ethylbenzene concentration/content Range (0,050-1128) mg/m3 Range (0,0010-8,10) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | Principles and Methods of Assessing the Working Environment 2011, No. 1 (67), pp. 35–44 | |
| 80 | Workplace environment − air − air samples collected on solid sorbent | Hexane concentration/content Range (0,10-569) mg/m3 Range (0,0010-4,10) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04136-3:2003 | |
| 81 | Workplace environment − air − air samples collected on solid sorbent | Cyclohexanone concentration/content Range (0,10-333) mg/m3 Range (0,0010-2,40) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04447:2014-06 | |
| 82 | Workplace environment − air − air samples collected on solid sorbent | Cyclohexane concentration/content Range (0,050-1124) mg/m3 Range (0,0010-8,10) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | Principles and Methods of Assessing the Working Environment 2011, No. 1 (67), pp. 35–44 | |
| 83 | Workplace environment − air − air samples collected on solid sorbent | Heptane concentration/content Range (0,139-6776) mg/m3 Range (0,0010-16,30) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | Principles and Methods of Assessing the Working Environment 2004 No. 4(42) pp. 67-73 | |
| 84 | Workplace environment − air − air samples collected on solid sorbent | Vinyl acetate concentration/content Range (0,10-333) mg/m3 Range (0,0010-2,40) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-87-Z-04178/02 | |
| 85 | Workplace environment − air − air samples collected on solid sorbent | Acrylonitrile concentration/content Range (0,050-500) mg/m3 Range (0,02 – 227) ppm Range (0,0010-3,60) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04113-12:2005 | |
| 86 | Workplace environment − air − air samples collected on solid sorbent | Dichloromethane concentration/content Range (0,10-569) mg/m3 Range (0,03 – 161) ppm Range (0,0010-4,10) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-83-Z-04110/02 | |
| 87 | Workplace environment − air − air samples collected on solid sorbent | Concentration/content of trimethylbenzene – mixture of isomers: 1,2,3 trimethylbenzene Range (0,070-600) mg/m3 Range (0,0010-3,0) mg in the sample 1,2,4 trimethylbenzene Range (0,0670-620) mg/m3 Range (0,0010-3,10) mg in the sample 1,3,5 trimethylbenzene Range (0,0670-600) mg/m3 Range (0,0010-3,0) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04016-4:1998 | |
| 88 | Workplace environment − air − air samples collected on solid sorbent | Sum of concentrations/contents of trimethylbenzene – mixture of isomers (1,2,3; 1,2,4; 1,3,5) (calculated) Range (0,070 – 1820) mg/m3 Range (0,0010 – 9,10) mg in the sample |
PN-Z-04016-4:1998 | ||
| 89 | Workplace environment − air − air samples collected on solid sorbent | Concentration/content of tetrahydrofuran Range (0,0670-820) mg/m3 Range (0,0010-4,10) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | Principles and Methods of Assessing the Working Environment 2015 No. 4(86), pp. 191-202 | |
| 90 | Workplace environment − air − air samples collected on solid sorbent | Concentration/content of butan-2-ol Range (0,0670-1627) mg/m3 Range (0,0010-8,10) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04155-4:1996 | |
| 91 | Workplace environment − air − air samples collected on solid sorbent | Propan-2-ol concentration/content Range (0,20-7551) mg/m3 Range (0,0010-27,2) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-92-Z-04224/02 | |
| 92 | Workplace environment − air − air samples collected on solid sorbent | Tetrachloroethene concentration/content Range (0,10-569) mg/m3 Range (0,015 – 83) ppm Range (0,0010-4,10) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-78-Z-04118-01 | |
| 93 | Workplace environment − air − air samples collected on solid sorbent | Concentration/content of buta-1,3-diene Range (0,175 – 600) mg/m3 Range (0,08 – 267) ppm Range (0,00118 – 0,60) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-84-Z-04014/02 Principles and Methods of Assessing the Working Environment 2017, No. 1 (95), pp. 73–85 | |
| 94 | Workplace environment − air − air samples collected on solid sorbent | Concentration/content of chloroethene Range (0,5 - 60) mg/m3 Range (0,19 – 23) ppm Range (0,005 – 0,6) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-78-Z-04112/01 | |
| 95 | Workplace environment − air − air samples collected on solid sorbent | Concentration / content of 1-methoxy-2-propanol Range (0,050-569) mg/m3 Range (0,0010-4,10) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04354:2005 | |
| 96 | Workplace environment − air − air samples collected on solid sorbent | Concentration/content of butan-2-one Range (0,230-1250) mg/m3 Range (0,0010-3,0) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04449:2014-06 | |
| 97 | Workplace environment − air − air samples collected on solid sorbent | Concentration/content of 2-ethoxyethanol Range (0,0450 – 126) mg/m3 Range (0,01 – 33,7) ppm Range (0,00090 – 0,91) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04023-02:1989 | |
| 98 | Workplace environment − air − air samples collected on solid sorbent | 4-methylpentan-2-one concentration/content Range (0,050 – 600) mg/m3 Range (0,00070 – 3,00) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04372:2009 | |
| 99 | Workplace environment − air − air samples collected on solid sorbent | Methyl acrylate concentration/content Range (0,120 – 680) mg/m3 Range (0,00120 – 4,90) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04113-05:1989 | |
| 100 | Workplace environment − air − air samples collected on solid sorbent | Concentration / content of isopentane (2-methylbutane) Range (0,240 – 6777) mg/m3 Range (0,00070 – 6,10) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04376:2010 | |
| 101 | Workplace environment − air − air samples collected on solid sorbent | Concentration/content of butyl methacrylate Range (0,0740 – 920) mg/m3 Range (0,00110 – 4,60) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04283:2001 | |
| 102 | Workplace environment − air − air samples collected on solid sorbent | Concentration/content of methylcyclohexane Range (0,0750 – 3375) mg/m3 Range (0,00150 – 24,3) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | Principles and Methods of Assessing the Working Environment 2011 No. 1 (67), pp. 185-192 | |
| 103 | Workplace environment − air − air samples collected on solid sorbent | Concentration / content of 2-butoxyethyl acetate Range (0,050 – 416) mg/m3 Range (0,000710 – 1,50) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04304:2003 | |
| 104 | Workplace environment − air − air samples collected on solid sorbent | Concentration / content of 2-ethoxyethyl acetate Range (0,110 – 470) mg/m3 Range (0,02 – 86) ppm Range (0,00110 – 4,70) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04023-02:1989 | |
| 105 | Workplace environment − air − air samples collected on solid sorbent | Concentration / content of 2-methoxy-1-methylethyl acetate Range (0,150 – 3291) mg/m3 Range (0,001450 – 23,70) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04119-10:2008 | |
| 106 | Workplace environment − air − air samples collected on solid sorbent | Concentration / content of 2-methoxyethyl acetate Range (0,090 – 513) mg/m3 Range (0,02 – 104,7) ppm Range (0,00090 – 3,70) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | Principles and Methods of Assessing the Working Environment 2010, No. 1 (63), pp. 185–192 | |
| 107 | Workplace environment − air − air samples collected on solid sorbent | Isobutyl acetate concentration/content Range (0,110 – 2527) mg/m3 Range (0,00110 – 18,20) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04119-11:2008 | |
| 108 | Workplace environment − air − air samples collected on solid sorbent | Methyl acetate concentration/content Range (0,080 – 1820) mg/m3 Range (0,00110 – 9,10) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04119-01:1978 | |
| 109 | Workplace environment − air − air samples collected on solid sorbent | Concentration/content of propyl acetate Range (0,090 – 3020) mg/m3 Range (0,00090 – 15,10) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04119-11:2008 | |
| 110 | Workplace environment − air − air samples collected on solid sorbent | Concentration/content of ethyltoluene (mixture of isomers): 2-ethyltoluene 3-ethyltoluene 4-ethyltoluene Range (0,067 – 600,000) mg/m3 Range (0,001 – 3,0) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04016-5:1998 | |
| 111 | Workplace environment − air − air samples collected on solid sorbent | Sum of concentrations/contents of ethyltoluene (mixture of isomers) (calculated) Range (0,0670-1800) mg/m3 Range (0,0010 – 9,0) mg in the sample |
PN-Z-04016-5:1998 | ||
| 112 | Workplace environment − air − air samples collected on solid sorbent | Pentane concentration/content Range (0,340 – 9089) mg/m3 Range (0,0010 – 16,4) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04318:2005 | |
| 113 | Workplace environment − air − air samples collected on solid sorbent | Octane concentration/content Range (0,10 – 2277) mg/m3 Range (0,0010 – 4,10) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04166-02:1986 | |
| 114 | Workplace environment − air − air samples collected on solid sorbent | Phenol concentration/content Range (0,0670 – 920) mg/m3 Range (0,0010 – 4,6) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | Principles and Methods of Assessing the Working Environment 1999 No. 22, pp. 91-95 | |
| 115 | Workplace environment − air − air samples collected on solid sorbent | Formaldehyde concentration/content Range (0,0280 – 14) mg/m3 Range (0,0010 – 0,103) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | EV-IR-52 issue 1 of 14.10.2019 | based on NIOSH NMAM Fourth Edition 8/15/94 Method 2541, Issue 2 and OSHA Method 52 | |
| 116 | Workplace environment − air − air samples collected on solid sorbent | Concentration / content of 4-hydroxy-4-methylpentan-2-one (diacetone alcohol) Range (0,060 – 1027) mg/m3 Range (0,00090 – 7,40) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04368:2008 | |
| 117 | Workplace environment − air − air samples collected on solid sorbent | Concentration/content of isopropyl acetate Range (0,060 – 2111) mg/m3 Range (0,00090 – 15,20) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04119-7:2006 | |
| 118 | Workplace environment − air − air samples collected on solid sorbent | Chlorobenzene concentration/content Range (0,110 – 861) mg/m3 Range (0,00160 – 6,20) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04022-3:2001 | |
| 119 | Workplace environment − air − air samples collected on solid sorbent | Concentration/content of chloroform Range (0,40 – 500) mg/m3 Range (0,00120 – 0,60) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04187-02:1988 | |
| 120 | Workplace environment − air − air samples collected on solid sorbent | Concentration/content of butyl acrylate Range (0,120 – 333) mg/m3 Range (0,00120 – 2,4) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04113-06:1986 | |
| 121 | Workplace environment − air − air samples collected on solid sorbent | Concentration/content of cumene (isopropylbenzene) Range (0,070 – 569) mg/m3 Range (0,00100 – 4,10) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04016-6:1998 | |
| 122 | Workplace environment − air − air samples collected on solid sorbent | Concentration / content of epichlorohydrin (1-chloro-2,3-epoxypropane) Range (0,024 – 527) mg/m3 Range (0,01 – 137) ppm Range (0,000940 – 3,80) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04029-01:1981 | NIOSH Method 1010, Issue 2, 15 August 1994 | |
| 123 | Workplace environment − air − air samples collected on solid sorbent | Concentration/content of 2-(2-butoxyethoxy) ethanol Range (0,150 – 637) mg/m3 Range (0,00450 – 4,59) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04399:2011 | |
| 124 | Workplace environment − air − air samples collected on solid sorbent | Ethylene glycol concentration/content Range (0,210 – 444) mg/m3 Range (0,00650 – 3,20) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | Principles and Methods of Assessing the Working Environment 1997, No. 17 pp. 55-59 | |
| 125 | Workplace environment − air − air samples collected on solid sorbent | Concentration/content of 2-methoxyethanol Range (0,10 – 430) mg/m3 Range (0,03 – 136) ppm Range (0,0030 – 3,1) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04167-02:1986 Principles and Methods of Assessing the Working Environment 2010, No. 1 (63), pp. 169–175 | |
| 126 | Workplace environment − air − air samples collected on solid sorbent | Cresol concentration/content – mixture of isomers Range (0,340 – 350) mg/m3 Range (0,00170 – 0,42) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | Principles and Methods of Assessing the Working Environment 1999, No. 22 pp. 91-95 | |
| 127 | Workplace environment − air − air samples collected on solid sorbent | Acrylic acid concentration/content Range (0,67 – 722) mg/m3 Range (0,22 – 242) ppm Range (0,020 – 5,2) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04113-08:1992 | |
| 128 | Workplace environment − air − air samples collected on solid sorbent | Trichloroethene concentration/content Range (0,040 – 1138) mg/m3 Range (0,0010 – 8,20) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | NIOSH NMAM Fourth Edition 8/15/94, Method 1022, Issue 2 | |
| 129 | Workplace environment − air − air samples collected on solid sorbent | Methanol concentration/content Range (0,32 – 400) mg/m3 Range (0,0012 – 0,3) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04476:2016-10 | |
| 130 | Workplace environment − air − air samples collected on solid sorbent | Acetic acid concentration/content Range (0,021 – 138) mg/m3 Range (0,01 – 55) ppm Range (0,001 – 1,00) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04323:2004 | |
| 131 | Workplace environment − air − air samples collected on solid sorbent | Concentration/content of propan-1-ol Range (0,220 – 840) mg/m3 Range (0,00110 – 4,20) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | Principles and Methods of Assessing the Working Environment 1998, No. 19 pp. 160-164 | |
| 132 | Workplace environment − air − air samples collected on solid sorbent | Concentration / content of furfural Range (0,110 – 210) mg/m3 Range (0,00110 – 2,10) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04045-09:1992 | |
| 133 | Workplace environment − air − air samples collected on solid sorbent | Sevoflurane concentration/content Range (3,20 – 200) mg/m3 Range (0,0160 – 1,0) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04429:2011 | |
| 134 | Workplace environment − air − air samples collected on solid sorbent | Concentration/content of desflurane Range (3,20 – 200) mg/m3 Range (0,0160 – 1,0) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04422:2010 | |
| 135 | Workplace environment − air − air samples collected on solid sorbent | Kerosene concentration/content Range (1,850 – 625) mg/m3 Range (0,0370 – 4,50) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | NIOSH Method 1550, Issue 2, 15 August 1994 | |
| 136 | Workplace environment − air − air samples collected on solid sorbent | Concentration/content of acrylaldehyde (acrolein) Range (0,0040– 4,10) mg/m3 Range (0,01 – 1,76) ppm Range (0,000240 – 0,030) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04045-06:1982 | |
| 137 | Workplace environment − air − air samples collected on solid sorbent | Concentration/content of acetonitrile Range (4,7 – 300) mg/m3 Range (0,047 – 1,5) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04244-2:1996 | |
| 138 | Workplace environment − air − air samples collected on solid sorbent | Concentration/content of acetaldehyde Range (0,083 – 200) mg/m3 Range (0,0010 – 0,6) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | NIOSH METHOD 2538, Issue 2, dated 15 August 1994 | |
| 139 | Workplace environment − air − air samples collected on solid sorbent | Concentration/content of cyclohexanol Range (0,97 – 496) mg/m3 Range (0,0098 – 5) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | NIOSH METHOD 1402, Issue 2, 15 August 1994 | |
| 140 | Workplace environment − air − air samples collected on solid sorbent | Concentration/content of phenylmethanol (benzyl alcohol) Range (0,25 – 500) mg/m3 Range (0,0059 – 12) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | OSHA Method PV2009 | |
| 141 | Workplace environment − air − air samples collected on solid sorbent | Concentration / content of amyl acetate (pentyl acetate) Range (3,9 – 1000) mg/m3 Range (0,039 – 5) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | NIOSH METHOD 1450, Issue 3, 15 March 2003 | |
| 142 | Workplace environment − air − air samples collected on solid sorbent | Concentration / content of isoamyl acetate (isopentyl acetate) Range (3,9 – 1000) mg/m3 Range (0,039 – 5) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | NIOSH METHOD 1450, Issue 3, 15 March 2003 | |
| 143 | Workplace environment − air − air samples collected on solid sorbent | Concentration / content of 2-ethylhexan-1-ol Range (0,42 – 260) mg/m3 Range (0,010 – 1,3) mg in the sample Range (0,08 – 48) ppm |
Gas chromatography with flame ionization detection (GC-FID) | Principles and Methods of Assessing the Working Environment 2017, No. 2 (92), pp. 149–160 | |
| 144 | Workplace environment − air − air samples collected on solid sorbent | Concentration / content of 2-furylmethanol Range (1,9 – 240) mg/m3 Range (0,019 – 1,2) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04214-02:1990 | |
| 145 | Workplace environment − air − air samples collected on solid sorbent | Isoflurane concentration/content Range (1,25 – 80) mg/m 3 Range (0,00625 – 0,40) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04423:2011 | |
| 146 | Workplace environment − air − air samples collected on solid sorbent | Concentration/content of enflurane Range (1,25 – 80) mg/m3 Range (0,00625 – 0,40) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | Principles and Methods of Assessing the Working Environment 2023, No. 3 (117), 95-122 | |
| 147 | Workplace environment − air − air samples collected on filters | Hydrogen chloride concentration/content Range (0,50 – 10,0) mg/m3 Range (0,20 – 4,0) mg in the sample |
Spectrophotometric method | PN-Z-04450:2014-08 | |
| 148 | Workplace environment − air − air samples collected on filters | Concentration/content of chromium (VI) compounds – expressed as Cr(VI) Range (0,0005 – 0,027) mg/m3 Range (0,0005 – 0,020) mg in the sample |
Spectrophotometric method | PN-Z-04126-03:1987 | |
| 149 | Workplace environment − air − air samples collected on filters | Concentration/content of ammonium chloride Range (0,820 – 31,60) mg/m3 Range (0,0490 – 1,90) mg in the sample |
Spectrophotometric method | Principles and Methods of Assessing the Working Environment 1997, No. 16 pp. 39-42 | |
| 150 | Workplace environment − air − air samples collected on filters | Concentration/content of sodium heptaoxotetraborate decahydrate (10 hydrate) inhalable fraction Range (0,050 – 67) mg/m3 Range (0,0480 – 2,0) mg in the sample |
Spectrophotometric method | PN-Z-04235-3:2001 | |
| 151 | Workplace environment − air − air samples collected on filters | Concentration / content of highly refined mineral oil, excluding metalworking fluids – inhalable fraction Range (0,28 – 6,9) mg/m3 Range (0,2 – 5,0) mg in the sample |
Fourier transform infrared spectrometry (FT-IR) | PN-Z-04108-05:2006 | |
| 152 | Workplace environment − air − air samples collected on filters | Concentration/content of crystalline silica (quartz, cristobalite) – respirable fraction Range (0,010 – 0,2) mg/m3 Range (0,005 – 0,4) mg in the sample |
Fourier transform infrared spectrometry (FT-IR) | Principles and Methods of Assessing the Working Environment 2012, No. 4 (74), pp. 117–130 | |
| 153 | Work environment − air − air samples collected in a plastic bag General environment – waste gas samples - biogas samples - collected in a plastic bag | Dinitrogen oxide (nitrous oxide) concentration Range (3,7 – 3660) mg/m3 Range (2,0 – 1999,2) ppm |
Fourier transform infrared spectrometry (FT-IR) | EV-PB-18 issue 2 of 13.01.2026 | |
| 154 | Workplace environment − air − air samples collected into absorbing solutions | Concentration/content of sulphur dioxide (SO2) Range (0,123 – 6,40) mg/m3 Range (0,046 – 2,41) ppm Range (0,00160 – 0,0640) mg in the sample |
Spectrophotometric method | PN-Z-04015-12:1996 | PN-Z-04015-12/Ap1:2001 | |
| 155 | Workplace environment − air − air samples collected into absorbing solutions | Formic acid concentration/content Range (0,490 – 16,60) mg/m3 Range (0,00625 – 0,20) mg in the sample |
Spectrophotometric method | PN-Z-04196-02:1988 | |
| 156 | Workplace environment − air − air samples collected into absorbing solutions | Concentration / content of hydrazine Range (0,00130 – 0,040) mg/m3 Range (0,001 – 0,03) ppm Range (0,0000260 – 0,00080) mg in the sample |
Spectrophotometric method | PN-Z-04148-02:1985 | |
| 157 | Workplace environment − air − air samples collected on filters | Concentration/Content of iron oxides – calculated as Fe iron (III) oxide, iron (II) oxide, triiron tetraoxide inhalable fraction Range (0,034 – 25,0) mg/m3 Range (0,025 – 10,0) mg in the sample respirable fraction Range (0,032 – 25,0) mg/m3 Range (0,025 – 10,0) mg in the sample |
Flame atomic absorption spectrometry (FAAS) | PN-Z-04469:2025-02 | |
| 158 | Workplace environment − air − air samples collected on filters | Concentration/content of manganese and its inorganic compounds – expressed as Mn inhalable fraction Range (0,0014 – 0,80) mg/m3 Range (0,0010 – 0,60) mg in the sample respirable fraction Range (0,0013 – 0,75) mg/m3 Range (0,0010 – 0,60) mg in the sample |
Flame atomic absorption spectrometry (FAAS) | PN-Z-04472:2015-10 | PN-Z-04472:2015-10/Ap1:2015-12 | |
| 159 | Workplace environment − air − air samples collected on filters | Concentration/content of cadmium and its inorganic compounds – calculated as Cd inhalable fraction Range (0,00010 – 0,0078 ) mg/m3 Range (0,00010 – 0,0075) mg in the sample |
Flame atomic absorption spectrometry (FAAS) | PN-Z-04102-3:2013-10 | |
| 160 | Workplace environment − air − air samples collected on filters | Metallic nickel concentration/content Range (0,0014 – 0,694) mg/m3 Range (0,0010– 0,50) mg in the sample |
Flame atomic absorption spectrometry (FAAS) | PN-Z-04502:2019-10 EV-IR-72 issue 1 of 03.01.2025 | |
| 161 | Workplace environment − air − air samples collected on filters | Concentration/content of nickel compounds – calculated as Ni respirable fraction Range (0,0014-0,69) mg/m3 Range (0,0010 – 0,50) mg in the sample inhalable fraction Range (0,0014-0,69) mg/m3 Range (0,0010 – 0,50) mg in the sample |
Flame atomic absorption spectrometry (FAAS) | PN-Z-04502:2019-10 EV-IR-72 issue 1 of 03.01.2025 | |
| 162 | Workplace environment − air − air samples collected on filters | Concentration/content of lead and its inorganic compounds expressed as Pb – inhalable fraction Range (0,0021 – 0,111) mg/m3 Range (0,00150 – 0,080) mg in the sample |
Flame atomic absorption spectrometry (FAAS) | PN-Z-04487:2017-10 | |
| 163 | Workplace environment − air − air samples collected on filters | Concentration/content of antimony and its inorganic compounds, except stibine – calculated as Sb Range (0,028 – 1,38) mg/m3 Range (0,020 – 1,0) mg in the sample |
Flame atomic absorption spectrometry (FAAS) | PN-Z-04146-3:2006 | |
| 164 | Workplace environment − air − air samples collected on filters | Concentration/content of zinc oxide – calculated as Zn inhalable fraction Range (0,0017 – 25,0) mg/m3 Range (0,001250 – 10,4) mg in the sample |
Flame atomic absorption spectrometry (FAAS) | PN-87/Z-04100.03 | |
| 165 | Workplace environment − air − air samples collected on filters | Sodium hydroxide concentration/content Range (0,012 – 2,5) mg/m3 Range (0,0087 – 1,740) mg in the sample |
Flame atomic absorption spectrometry (FAAS) | PN-Z-04435:2011 | |
| 166 | Workplace environment − air − air samples collected on filters | Potassium hydroxide concentration/content Range (0,010 – 2,5) mg/m3 Range (0,00720 – 1,20) mg in the sample |
Flame atomic absorption spectrometry (FAAS) | PN-Z-04436:2011 | |
| 167 | Workplace environment − air − air samples collected on filters | Calcium oxide concentration/content inhalable fraction: Range (0,10 – 15,0) mg/m3 Range (0,07 – 4,60) mg in the sample respirable fraction: Range (0,09 – 15,0) mg/m3 Range (0,07 – 4,60) mg in the sample |
Flame atomic absorption spectrometry (FAAS) | PN-Z-04442:2023-10 | |
| 168 | Workplace environment − air − air samples collected on filters | Concentration/content of calcium carbonate inhalable fraction: Range (0,22 – 25,8) mg/m3 Range (0,160 – 18,60) mg in the sample |
Flame atomic absorption spectrometry (FAAS) | PN-Z-04294:2001 | |
| 169 | Workplace environment − air − air samples collected on filters | Magnesium oxide concentration/content inhalable fraction Range (0,47 – 22,7) mg/m3 Range (0,340 – 16,4) mg in the sample |
Flame atomic absorption spectrometry (FAAS) | PN-Z-04470:2015-10 | |
| 170 | Workplace environment − air − air samples collected on filters | Concentration/content of tin and its inorganic compounds, except stannane – calculated as Sn inhalable fraction Range (0,174 – 4,16) mg/m3 Range (0,1250 – 3,0) mg in the sample |
Flame atomic absorption spectrometry (FAAS) | PN-Z-04488:2017-10 | |
| 171 | Workplace environment − air − air samples collected on filters | Concentration/content of selenium and its compounds, except selane – calculated as Se Range (0,0069 – 0,70) mg/m3 Range (0,0050 – 0,40) mg in the sample |
Flame atomic absorption spectrometry (FAAS) | PN-Z-04468:2015-10 | |
| 172 | Workplace environment − air − air samples collected on filters | Concentration/content of cobalt and its inorganic compounds – calculated as Co Range (0,0014 – 0,069) mg/m3 Range (0,0010 – 0,050) mg in the sample |
Flame atomic absorption spectrometry (FAAS) | PN-Z-04291:2003 | |
| 173 | Workplace environment − air − air samples collected on filters | Concentration / content of metallic chromium and chromium compounds (chromium (II), chromium (III), chromium (VI)) – expressed as Cr Range (0,010 – 1,38) mg/m3 Range (0,0075 – 1,0) mg in the sample |
Flame atomic absorption spectrometry (FAAS) | PN-Z-04434:2011 | |
| 174 | Workplace environment − air − air samples collected on filters | Concentration/content of metallic chromium, chromium (II) compounds - expressed as Cr (II), chromium (III) compounds – expressed as Cr (III) | Calculation method | EV-PB-17, issue 1 of 18.12.2023 | |
| 175 | Workplace environment − air − air samples collected on filters | Concentration/content of copper and its inorganic compounds – calculated as Cu Range (0,0014 - 1,38) mg/m3 Range (0,0010 – 1,0) mg in the sample |
Flame atomic absorption spectrometry (FAAS) | PN-79/Z-04106.02 EV-IR-68 issue 1 of 18.12.2023 cl. 5.1 | |
| 176 | Workplace environment − air − air samples collected on filters | Concentration/content of iron oxides – expressed as Fe iron (III) oxide, iron (II) oxide, triiron tetraoxide inhalable fraction Range (0,0028 – 25,0) mg/m3 Range (0,0020 – 10,0) mg in the sample respirable fraction Range (0,0025 – 25,0) mg/m3 Range (0,0020 – 10,0) mg in the sample |
Flame atomic absorption spectrometry (FAAS) | PN-79/Z-04106.02 EV-IR-68 issue 1 of 18.12.2023 cl. 5.1 | |
| 177 | Workplace environment − air − air samples collected on filters | Concentration/content of manganese and its inorganic compounds – expressed as Mn inhalable fraction Range (0,0014 – 0,80) mg/m3 Range (0,0010 – 0,60) mg in the sample respirable fraction Range (0,0013–0,75) mg/m3 Range (0,0010 – 0,60) mg in the sample |
Flame atomic absorption spectrometry (FAAS) | PN-79/Z-04106.02 EV-IR-68 issue 1 of 18.12.2023 cl. 5.1 | |
| 178 | Workplace environment − air − air samples collected on filters | Concentration / content of metallic chromium and chromium compounds (chromium (II), chromium (III), chromium (VI)) – expressed as Cr Range (0,0083 – 1,11) mg/m3 Range (0,0060 – 0,80) mg in the sample |
Flame atomic absorption spectrometry (FAAS) | PN-Z-04106-02:1979 | |
| 179 | Workplace environment − air − air samples collected on filters | Metallic nickel concentration/content Range (0,0014 – 0,69) mg/m3 Range (0,0010 – 0,50) mg in the sample |
Flame atomic absorption spectrometry (FAAS) | PN-Z-04106-02:1979 EV-IR-72 issue 1 of 03.01.2025 | |
| 180 | Workplace environment − air − air samples collected on filters | Concentration/content of nickel compounds – calculated as Ni respirable fraction Range (0,0009 - 0,47) mg/m3 Range (0,0010 – 0,50) mg in the sample inhalable fraction Range (0,0014 - 0,69) mg/m3 Range (0,0010 – 0,50) mg in the sample |
Flame atomic absorption spectrometry (FAAS) | PN-Z-04106-02:1979 EV-IR-72 issue 1 of 03.01.2025 | |
| 181 | Waste gases | Gas volume flow rate for dynamic pressures > 10 Pa Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Stagnation pressure method | PN-Z-04030-7:1994 | |
| 182 | Waste gases | Gas volume flow rate for velocity Range (0,6 – 40) m/s Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Anemometric method | PN-Z-04030-7:1994 | |
| 183 | Waste gases | Sampling for determination of dust concentration Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
PN-Z-04030-7:1994 | ||
| 184 | Waste gases | Dust concentration Range (0,001 – 21,9) g/m3 Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Gravimetric method | PN-Z-04030-7:1994 | |
| 185 | Waste gases | Dust emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
PN-Z-04030-7:1994 | ||
| 186 | Waste gases | Oxygen concentration Range (2,9 – 22,5) % Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Paramagnetic method (PMD) | PN-ISO 10396:2001 | |
| 187 | Waste gases | CO, CO2 concentration CO (1,25 – 5467) mg/m3 CO2 (0,2 – 27,5) % Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Non-dispersive infrared spectrometry (NDIR) | PN-ISO 10396:2001 | |
| 188 | Waste gases | Emission of CO, CO2 (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
PN-ISO 10396:2001 | ||
| 189 | Waste gases | NO, NOx concentration NO (1,4 – 3347) mg/m3 NOx (2,1 – 5125) mg/m3 Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Chemiluminescence method (CLD) | PN-ISO 10396:2001 | |
| 190 | Waste gases | Emission of NO, NOx (NOx expressed as NO2) (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
PN-ISO 10396:2001 | ||
| 191 | Waste gases | SO2 concentration Range (2,9 – 5358) mg/m3 Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Non-dispersive infrared spectrometry (NDIR) | PN-ISO 10396:2001 | |
| 192 | Waste gases | SO2 emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
PN-ISO 10396:2001 | ||
| 193 | Waste gases | Sampling for determination of hydrogen chloride concentration Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
PN-EN 1911:2011 | ||
| 194 | Waste gases | Hydrogen chloride concentration/content Range (0,130 – 231) mg/m3 Range (0,026 – 23,1) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Spectrophotometric method | PN-EN 1911:2011 | |
| 195 | Waste gases | HCl emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
PN-EN 1911:2011 | ||
| 196 | Waste gases | Sampling for determination of hydrogen fluoride concentration Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
ISO 15713:2006 | ||
| 197 | Waste gases | HF emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
ISO 15713:2006 | ||
| 198 | Waste gases | Sampling for determination of metal concentrations: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
PN-EN 14385:2005 | ||
| 199 | Waste gases | Gas volume flow rate for differential pressures > 5 Pa Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Differential pressure measurement method | PN-EN ISO 16911-1:2013-07 CEN/TR 17078:2017 | |
| 200 | Waste gases | Water vapour concentration (H2O) Range (29 – 250) g/m3 Range (4,0 – 40,0) % Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Condensation-adsorption method | PN-EN 14790:2017-04 | |
| 201 | Waste gases | Oxygen concentration Range (2,9 – 22,5) % Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Paramagnetic method (PMD) | PN-EN 14789:2017-04 | |
| 202 | Waste gases | CO2 concentration Range (0,2 – 27,5) % Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Non-dispersive infrared spectrometry (NDIR) | ISO 12039:2019 | |
| 203 | Waste gases | CO2 emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
ISO 12039:2019 | ||
| 204 | Waste gases | CO concentration Range (1,25 – 5467) mg/m3 Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Non-dispersive infrared spectrometry (NDIR) | PN-EN 15058:2017-04 | |
| 205 | Waste gases | CO emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
PN-EN 15058:2017-04 | ||
| 206 | Waste gases | NO, NOx concentration NO (1,4 – 3347) mg/m3 NOx (2,1 – 5125) mg/m3 Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Chemiluminescence method (CLD) | PN-EN 14792:2017-04 | |
| 207 | Waste gases | Emission of NO, NOx (NOx expressed as NO2) (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
PN-EN 14792:2017-04 | ||
| 208 | Waste gases | Sampling for the determination of sulfur dioxide concentration Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
PN-EN 14791:2017-04 | ||
| 209 | Waste gases | Sulphur dioxide emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
PN-EN 14791:2017-04 | ||
| 210 | Waste gases | Concentration / content of metals Cd (0,0010 – 20) mg/m3 Range (0,00010 – 10) mg in the sample Cr (0,00150 – 20) mg/m3 (0,0150 – 10) mg in the sample Co (0,00050 – 20) mg/m3 (0,0050 – 10) mg in the sample Cu (0,000250 – 20) mg/m3 (0,00250 – 10) mg in the sample Mn (0,000250 – 20) mg/m3 (0,00250 – 10) mg in the sample Ni (0,00050 – 20) mg/m3 (0,0050 – 10) mg in the sample Pb (0,000750 - 20) mg/m3 (0,00750 – 10) mg in the sample Sb (0,010 – 20) mg/m3 (0,10 – 10) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Flame atomic absorption spectrometry (FAAS) | PN-EN 14385:2005 | |
| 211 | Waste gases | Emission of metals: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
PN-EN 14385:2005 | ||
| 212 | Waste gases | Sampling for determination of total mercury concentration Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
PN-EN 13211+AC:2006 | ||
| 213 | Waste gases | Total mercury emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
PN-EN 13211+AC:2006 | ||
| 214 | Waste gases | Sampling for determination of the concentration of individual gaseous organic compounds Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
PN-EN 13649:2005 | ||
| 215 | Waste gases | Acetone concentration/content Range (0,017 – 2733) mg/m3 Range (0,001 – 4,1) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN 13649:2005 | |
| 216 | Waste gases | Concentration/content of xylene – mixture of isomers: m-xylene Range (0,017 - 2733) mg/m3 Range (0,001 – 4,1) mg in the sample o-xylene Range (0,017 - 2733) mg/m3 Range (0,001 – 4,1) mg in the sample p-xylene Range (0,0170 - 2667) mg/m3 Range (0,001 – 4,0) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN 13649:2005 | |
| 217 | Waste gases | Sum of xylene concentration/content – mixture of isomers (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
PN-EN 13649:2005 | ||
| 218 | Waste gases | Ethanol concentration/content Range (0,017 – 2733) mg/m3 Range (0,001 – 4,1) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN 13649:2005 | |
| 219 | Waste gases | Butan-1-ol concentration/content Range (0,017 – 2733) mg/m3 Range (0,001 – 4,1) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN 13649:2005 | |
| 220 | Waste gases | Concentration / content of 2-methylpropan-1-ol Range (0,017 – 2733) mg/m3 Range (0,001 – 4,1) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN 13649:2005 | |
| 221 | Waste gases | Ethyl acetate concentration/content Range (0,017 – 2733) mg/m3 Range (0,001 – 4,1) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN 13649:2005 | |
| 222 | Waste gases | Concentration/content of n-butyl acetate Range (0,017 – 2733) mg/m3 Range (0,001 – 4,1) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN 13649:2005 | |
| 223 | Waste gases | Toluene concentration/content Range (0,017 – 2733) mg/m3 Range (0,001 – 4,1) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN 13649:2005 | |
| 224 | Waste gases | 2-butoxyethanol concentration/content Range (0,017 – 2733) mg/m3 Range (0,001 – 4,1) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN 13649:2005 | |
| 225 | Waste gases | Benzene concentration/content Range (0,017– 2733) mg/m3 Range (0,001 – 4,1) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN 13649:2005 | |
| 226 | Waste gases | Styrene concentration/content Range (0,017- 2733) mg/m3 Range (0,001 – 4,1) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN 13649:2005 | |
| 227 | Waste gases | Methyl methacrylate concentration/content Range (0,017 – 2733) mg/m3 Range (0,001 – 4,5) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN 13649:2005 | |
| 228 | Waste gases | Ethylbenzene concentration/content Range (0,017– 2733) mg/m3 Range (0,001 – 4,1) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN 13649:2005 | |
| 229 | Waste gases | Cyclohexanone concentration/content Range (0,017 – 2733) mg/m3 Range (0,001 – 4,1) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN 13649:2005 | |
| 230 | Waste gases | Cyclohexane concentration/content Range (0,017 – 2667) mg/m3 Range (0,001 – 4,0) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN 13649:2005 | |
| 231 | Waste gases | Vinyl acetate concentration/content Range (0,017 – 2733) mg/m3 Range (0,001 – 4,1) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN 13649:2005 | |
| 232 | Waste gases | Acrylonitrile concentration/content Range (0,017 – 2667) mg/m3 Range (0,001 – 4) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN 13649:2005 | |
| 233 | Waste gases | Dichloromethane concentration/content Range (0,017– 2733) mg/m3 Range (0,001 – 4,1) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN 13649:2005 | |
| 234 | Waste gases | Concentration/content of trimethylbenzene – mixture of isomers 1, 2, 3 trimethylbenzene Range (0,017– 2667) mg/m3 Range (0,001 – 4) mg in the sample 1, 2, 4 trimethylbenzene Range (0,017 – 2733) mg/m3 Range (0,001 – 4,1) mg in the sample 1, 3, 5 trimethylbenzene Range (0,017 – 2733) mg/m3 Range (0,001 – 4,1) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN 13649:2005 | |
| 235 | Waste gases | Sum of trimethylbenzene concentration/content – mixture of isomers (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
PN-EN 13649:2005 | ||
| 236 | Waste gases | Concentration/content of tetrahydrofuran Range (0,017 – 2733) mg/m3 Range (0,001 – 4,1) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN 13649:2005 | |
| 237 | Waste gases | Concentration/content of butan-2-ol Range (0,017– 2733) mg/m3 Range (0,001 – 4,1) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN 13649:2005 | |
| 238 | Waste gases | Propan-2-ol concentration/content Range (0,017 – 3067) mg/m3 Range (0,001 – 4,6) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN 13649:2005 | |
| 239 | Waste gases | Acetic acid concentration/content Range (0,017 – 666) mg/m3 Range (0,001 – 1,00) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN 13649:2005 | |
| 240 | Waste gases | Tetrachloroethene concentration/content Range (0,017 – 2733) mg/m3 Range (0,001 – 4,1) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN 13649:2005 | |
| 241 | Waste gases | Concentration/content of buta-1,3-diene Range (0,020 – 400) mg/m3 Range (0,00118 – 0,60) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN 13649:2005 | |
| 242 | Waste gases | Concentration/content of vinyl chloride Range (0,13 – 60,1) mg/m3 Range (0,004 – 0,2) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN 13649:2005 | |
| 243 | Waste gases | Concentration / content of 1-methoxy-2-propanol Range (0,017– 2733) mg/m3 Range (0,001 – 4,1) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN 13649:2005 | |
| 244 | Waste gases | Concentration/content of butan-2-one Range (0,017 – 2733) mg/m3 Range (0,001 – 4,1) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN 13649:2005 | |
| 245 | Waste gases | Concentration/content of aliphatic hydrocarbons: pentane Range (0,017 – 2733) mg/m3 Range (0,001 – 4,1) mg in the sample hexane Range (0,017 – 2733) mg/m3 Range (0,001 – 4,1) mg in the sample heptane Range (0,017- 2733) mg/m3 Range (0,001 – 4,1) mg in the sample octane Range (0,017- 2733) mg/m3 Range (0,001 – 4,1) mg in the sample nonane Range (0,017- 2733) mg/m3 Range (0,001 – 4,1) mg in the sample decane Range (0,017- 2733) mg/m3 Range (0,001 – 4,1) mg in the sample undecane Range (0,017- 2733) mg/m3 Range (0,001 – 4,1) mg in the sample dodecane Range (0,017- 2733) mg/m3 Range (0,001 – 4,1) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN 13649:2005 | |
| 246 | Waste gases | Sum of concentrations/contents of aliphatic hydrocarbons C5-C12 (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
PN-EN 13649:2005 | ||
| 247 | Waste gases | Concentration/content of ethyltoluene – mixture of isomers: 2-ethyltoluene Range (0,017- 2733) mg/m3 Range (0,001 – 4,1) mg in the sample 3-ethyltoluene Range (0,017- 2733) mg/m3 Range (0,001 – 4,1) mg in the sample 4-ethyltoluene Range (0,017- 2733) mg/m3 Range (0,001 – 4,1) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN 13649:2005 | |
| 248 | Waste gases | Sum of ethyltoluene concentration/content (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
PN-EN 13649:2005 | ||
| 249 | Waste gases | Sum of aromatic hydrocarbon concentration/content (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
PN-EN 13649:2005 | ||
| 250 | Waste gases | Phenol concentration/content Range (0,017 – 3067) mg/m3 Range (0,001 – 4,6) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN 13649:2005 | |
| 251 | Waste gases | Concentration/content of cumene Range (0,017 –2733) mg/m3 Range (0,001 – 4,1) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN 13649:2005 | |
| 252 | Waste gases | Concentration/content of 2-ethoxyethanol Range (0,0150 – 606) mg/m3 Range (0,00090 – 0,91) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN 13649:2005 | |
| 253 | Waste gases | 4-methylpentan-2-one concentration/content Range (0,0120 – 2000) mg/m3 Range (0,00070 – 3,0) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN 13649:2005 | |
| 254 | Waste gases | Concentration/content of butyl acrylate Range (0,020 – 1600) mg/m3 Range (0,00120 – 2,40) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN 13649:2005 | |
| 255 | Waste gases | Methyl acrylate concentration/content Range (0,020 – 3266) mg/m3 Range (0,00120 – 4,90) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN 13649:2005 | |
| 256 | Waste gases | Concentration / content of isopentane (2-methylbutane) Range (0,0120 – 4066) mg/m3 Range (0,00070 – 6,10) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN 13649:2005 | |
| 257 | Waste gases | Concentration/content of butyl methacrylate Range (0,0190 – 3066) mg/m3 Range (0,00110 – 4,60) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN 13649:2005 | |
| 258 | Waste gases | Concentration/content of methylcyclohexane Range (0,0250 – 16200) mg/m3 Range (0,00150 – 24,30) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN 13649:2005 | |
| 259 | Waste gases | Concentration / content of 2-butoxyethyl acetate Range (0,0120 – 1000) mg/m3 Range (0,000710 – 1,50) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN 13649:2005 | |
| 260 | Waste gases | Concentration / content of 2-ethoxyethyl acetate Range (0,0190 – 3133) mg/m3 Range (0,00110 – 4,70) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN 13649:2005 | |
| 261 | Waste gases | Concentration / content of 2-methoxy-1-methylethyl acetate Range (0,0250 – 15800) mg/m3 Range (0,00145 – 23,70) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN 13649:2005 | |
| 262 | Waste gases | Concentration / content of 2-methoxyethyl acetate Range (0,0150 – 2466) mg/m3 Range (0,00090 – 3,70) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN 13649:2005 | |
| 263 | Waste gases | Isobutyl acetate concentration/content Range (0,01840 – 12133) mg/m3 Range (0,00110 – 18,20) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN 13649:2005 | |
| 264 | Waste gases | Methyl acetate concentration/content Range (0,0190 – 6066) mg/m3 Range (0,00110 – 9,10) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN 13649:2005 | |
| 265 | Waste gases | Concentration/content of propyl acetate Range (0,0150 – 10066) mg/m3 Range (0,00090 – 15,10) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN 13649:2005 | |
| 266 | Waste gases | Concentration / content of 4-hydroxy-4-methylpentan-2-one (diacetone alcohol) Range (0,0150 – 4933) mg/m3 Range (0,00090 – 7,40) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN 13649:2005 | |
| 267 | Waste gases | Concentration/content of isopropyl acetate Range (0,0150 – 10133) mg/m3 Range (0,00090 – 15,20) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN 13649:2005 | |
| 268 | Waste gases | Chlorobenzene concentration/content Range (0,0270 – 4133) mg/m3 Range (0,00160 – 6,20) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN 13649:2005 | |
| 269 | Waste gases | Concentration/content of chloroform Range (0,020 – 400) mg/m3 Range (0,00120 – 0,60) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN 13649:2005 | |
| 270 | Waste gases | n-Propylbenzene concentration/content Range (0,0170 – 2733) mg/m3 Range (0,00100 – 4,10) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN 13649:2005 | |
| 271 | Waste gases | Concentration/content of 1-ethoxypropan-2-ol Range (0,0190 – 2866) mg/m3 Range (0,00100 – 4,30) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN 13649:2005 | |
| 272 | Waste gases | Formaldehyde concentration/content Range (0,01670 – 68) mg/m3 Range (0,0010 – 0,103) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN 13649:2005 EV-IR-52 issue 1 of 14.10.2019 | based on NIOSH NMAM Fourth Edition 8/15/94 Method 2541, Issue 2 and OSHA Method 52 | |
| 273 | Waste gases | Concentration / content of epichlorohydrin (1-chloro-2,3-epoxypropane) Range (0,0160 – 2533) mg/m3 Range (0,000940 – 3,80) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN 13649:2005 | |
| 274 | Waste gases | Concentration/content of 2-(2-butoxyethoxy) ethanol Range (0,075 – 3060) mg/m3 Range (0,00450 – 4,59) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN 13649:2005 | |
| 275 | Waste gases | Ethylene glycol concentration/content Range (0,11 – 2133) mg/m3 Range (0,00650 – 3,20) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN 13649:2005 | |
| 276 | Waste gases | Concentration/content of 2-methoxyethanol Range (0,050 – 2066) mg/m3 Range (0,0030 – 3,1) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN 13649:2005 | |
| 277 | Waste gases | Cresol concentration/content – mixture of isomers Range (0,029 – 280) mg/m3 Range (0,00170 – 0,42) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN 13649:2005 | |
| 278 | Waste gases | Acrylic acid concentration/content Range (0,33 – 3466) mg/m3 Range (0,020 – 5,2) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN 13649:2005 | |
| 279 | Waste gases | Trichloroethene concentration/content Range (0,017 – 5466) mg/m3 Range (0,0010 – 8,20) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN 13649:2005 | |
| 280 | Waste gases | Methanol concentration/content Range (0,02 – 200) mg/m3 Range (0,0012 – 0,3) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN 13649:2005 | |
| 281 | Waste gases | Concentration/content of propan-1-ol Range (0,01840 – 2800) mg/m3 Range (0,00110 – 4,20) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN 13649:2005 | |
| 282 | Waste gases | Concentration/content of acetaldehyde Range (0,01670 – 400) mg/m3 Range (0,00100 – 0,6) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN 13649:2005 | |
| 283 | Waste gases | Concentration / content of furfural Range (0,01840 – 1400) mg/m3 Range (0,00110 – 2,10) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN 13649:2005 | |
| 284 | Waste gases | Concentration/content of acrylaldehyde (acrolein) Range (0,0040 – 20,0) mg/m3 Range (0,000240 – 0,030) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN 13649:2005 | |
| 285 | Waste gases | Concentration/content of acetonitrile Range (0,79 – 1000) mg/m3 Range (0,047 – 1,5) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN 13649:2005 | |
| 286 | Waste gases | Concentration/content of cyclohexanol Range (0,17 – 3333) mg/m3 Range (0,0098 – 5) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN 13649:2005 | |
| 287 | Waste gases | Concentration/content of phenylmethanol (benzyl alcohol) Range (0,10 – 8000) mg/m3 Range (0,0059 – 12) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN 13649:2005 | |
| 288 | Waste gases | Concentration / content of amyl acetate (pentyl acetate) Range (0,65 – 3333) mg/m3 Range (0,039 – 5) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN 13649:2005 | |
| 289 | Waste gases | Concentration / content of isoamyl acetate (isopentyl acetate) Range (0,65 – 3333) mg/m3 Range (0,039 – 5) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN 13649:2005 | |
| 290 | Waste gases | Concentration / content of 2-ethylhexan-1-ol Range (0,17 – 866) mg/m3 Range (0,010 – 1,3) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN 13649:2005 | |
| 291 | Waste gases | Concentration / content of 2-furylmethanol Range (0,32 – 800) mg/m3 Range (0,019 – 1,2) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN 13649:2005 | |
| 292 | Waste gases | Emission of individual gaseous organic compounds (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
PN-EN 13649:2005 | ||
| 293 | Waste gases | Concentration of organic substances in the form of gases and vapours expressed as total gaseous organic carbon Range (8,0 - 1280) mg/m3 Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
Continuous flame ionization detection method (FID) | PN-EN 12619:2013-05 | |
| 294 | Waste gases | Emission of organic substances in gaseous and vapour form expressed as total gaseous organic carbon (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law |
PN-EN 12619:2013-05 | ||
| 295 | Waste gases | Sampling for determination of hydrogen sulphide concentration | EV-PB-5 issue 3 of 31.03.2025 | ||
| 296 | Waste gases | Hydrogen sulphide emission (calculated) | EV-PB-5 issue 3 of 31.03.2025 | ||
| 297 | Waste gases | Hydrogen sulphide concentration/content Range (0,830 – 66,7) mg/m3 Range (0,050 – 2,0) mg in the sample |
Spectrophotometric method | EV-PB-7 issue 2 of 17.04.2018 | |
| 298 | Waste gases | Dust sampling for the determination of PM 1, PM 2,5 and PM 10 concentration | PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02 EV-IR-48 issue 2 of 26.03.2026 | ||
| 299 | Waste gases | Emission of PM 1, PM 2,5 and PM 10 dust (calculated) | PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02 EV-IR-48 issue 2 of 26.03.2026 | ||
| 300 | Waste gases | Sampling for the determination of ozone concentration | EV-PB-11 issue 2 of 01.04.2021 | ||
| 301 | Waste gases | Ozone concentration/content Range (0,0150 – 0,450) mg/m3 Range (0,0010 – 0,0180) mg in the sample |
Spectrophotometric method | PN-Z-04007-2:1994 excluding cl. 7 EV-IR-53 issue 1 of 14.10.2019 | |
| 302 | Waste gases | Ozone emission (calculated) | EV-PB-11 issue 2 of 01.04.2021 | ||
| 303 | Waste gases | Sampling for determination of formaldehyde concentration | EV-PB-11 issue 2 of 01.04.2021 | ||
| 304 | Waste gases | Formaldehyde concentration/content Range (0,0670 – 66) mg/m3 Range (0,0040 – 0,40) mg in the sample |
Spectrophotometric method | PN-76/Z-04045/02 and EV-IR/54 issue 1 of 31.01.2020 | |
| 305 | Waste gases | Formaldehyde emission (calculated) | EV-PB-11 issue 2 of 01.04.2021 | ||
| 306 | Waste gases | Sampling for determination of sulfuric acid concentration | EV-PB-10 issue 3 of 17.03.2026 | ||
| 307 | Waste gases | Sulfuric acid concentration/content Range (0,0190 – 29,9) mg/m3 Range (0,20 – 5) mg in the sample |
Spectrophotometric method | EV-PB-10 issue 3 of 17.03.2026 | |
| 308 | Waste gases | Sulfuric acid emission (calculated) | EV-PB-10 issue 3 of 17.03.2026 | ||
| 309 | Waste gases | Sampling for determination of chromium (VI) concentration | EV-PB-9 issue 2 of 01.04.2021 | ||
| 310 | Waste gases | Concentration/content of chromium (VI) Range (0,0000910 – 0,0390) mg/m3 Range (0,00050 – 0,020) mg in the sample |
Spectrophotometric method | EV-PB-9 issue 2 of 01.04.2021 | |
| 311 | Waste gases | Emission of chromium (VI) (calculated) | EV-PB-9 issue 2 of 01.04.2021 | ||
| 312 | Waste gases | Sampling for determination of ammonia concentration | PN-EN ISO 21877:2020-03 | ||
| 313 | Waste gases | Ammonia concentration/content Range (0,05 – 400) mg/m3 Range (0,005 – 12) mg in the sample |
Spectrophotometric method | PN-EN ISO 21877:2020-03 | |
| 314 | Waste gases | Ammonia emission (calculated) | PN-EN ISO 21877:2020-03 | ||
| 315 | Dust samples | Proportion of dust fractions (particle size distribution) including PM 1; PM 2,5; PM 10 Range (0,1 – 3800) μm Range (0 – 100) % |
Laser diffraction method | ISO 13320:2020 | |
| 316 | Waste gases | Sampling for determination of dust concentration | PN-EN 13284-1:2018-02 | ||
| 317 | Waste gases | Dust concentration Range (0,1 – 50) mg/m3 |
Gravimetric method | PN-EN 13284-1:2018-02 | |
| 318 | Waste gases | Dust emission (calculated) | PN-EN 13284-1:2018-02 | ||
| 319 | Waste gases | Sampling for determination of metal concentrations: Zn, Fe, Sn | PN-EN 14385:2005 EV-PB-16 issue 3 of 25.03.2024 | ||
| 320 | Waste gases | Concentration / content of metals Zn (0,000250 – 20) mg/m3 Range (0,00250 – 10) mg in the sample Fe (0,00050 – 20) mg/m3 (0,0050 – 10) mg in the sample Sn (0,0250 – 20) mg/m3 (0,250 – 10) mg in the sample |
Flame atomic absorption spectrometry (FAAS) | PN-EN 14385:2005 EV-PB-16 issue 3 of 25.03.2024 | |
| 321 | Waste gases | Emission of metals: Zn, Fe, Sn (calculated) | PN-EN 14385:2005 EV-PB-16 issue 3 of 25.03.2024 | ||
| 322 | Rooms intended for human occupancy – air | Sampling for the determination of organic compound concentration | EV-PB-14 issue 2 of 28.03.2023 | ||
| 323 | Rooms intended for human occupancy: – air – air samples collected on sorbent tubes | Concentration/Content: acrylonitrile Range (2,0 – 4000) μg/m3 Range (0,0010 – 4,00) mg in the sample benzene Range (2,0 – 4000) μg/m3 Range (0,0010 – 4,00) mg in the sample buta-1,3-diene Range (9,0 – 4000) μg/m3 Range (0,0012 – 0,60) mg in the sample butan-1-ol (butyl alcohol) Range (2,0 – 4000) μg/m3 Range (0,0010 – 4,00) mg in the sample vinyl chloride Range (4,9 – 4000) μg/m3 Range (0,0007 – 0,70) mg in the sample chlorobenzene Range (3,2 – 4000) μg/m3 Range (0,0016 – 6,20) mg in the sample cyclohexane Range (2,0 – 4000) μg/m3 Range (0,0010 – 4,00) mg in the sample cyclohexanone Range (2,0 – 4000) μg/m3 Range (0,0010 – 4,00) mg in the sample ethylbenzene Range (2,0 – 4000) μg/m3 Range (0,0010 – 4,00) mg in the sample phenol Range (2,0 – 4000) μg/m3 Range (0,0010 – 4,50) mg in the sample formaldehyde Range (7,0 – 600) μg/m3 Range (0,0010 – 0,100) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | EV-PB-13 issue 1 of 03.01.2023 EV-PB-14 issue 2 of 28.03.2023 | |
| 324 | Rooms intended for human occupancy: – air – air samples collected on sorbent tubes | Concentration/Content: ethylene glycol Range (13,0 – 4000) μg/m3 Range (0,0065 – 3,20) mg in the sample cresols - mixture of isomers Range (3,6 – 875) μg/m3 Range (0,0017 – 0,42) mg in the sample xylene – mixture of isomers Range (2,0 – 4000) μg/m3 Range (0,0010 – 8,00) mg in the sample butyl acetate Range (2,0 – 4000) μg/m3 Range (0,0010 – 4,00) mg in the sample ethyl acetate Range (2,0 – 4000) μg/m3 Range (0,0010 – 4,00) mg in the sample vinyl acetate Range (2,0 – 4000) μg/m3 Range (0,0010 – 4,00) mg in the sample styrene Range (2,0 – 4000) μg/m3 Range (0,0010 – 4,00) mg in the sample toluene Range (2,0 – 4000) μg/m3 Range (0,0010 – 4,00) mg in the sample trichloroethene Range (2,0 – 4000) μg/m3 Range (0,0010 – 8,20) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | EV-PB-13 issue 1 of 03.01.2023 EV-PB-14 issue 2 of 28.03.2023 | |
| 325 | Rooms intended for human occupancy: − air − air samples collected into a plastic bag | Dinitrogen oxide (nitrous oxide) concentration Range (3,7 – 3660) mg/m3 Range (2,0 – 1999,2) ppm |
Fourier transform infrared spectrometry (FT-IR) | EV-PB-18 issue 2 of 13.01.2026 | |
Reference standards (176)
EV-IR-52 issue 1 of 14.10.2019
EV-PB-1 issue 2 of 01.04.2021
EV-PB-10 issue 3 of 17.03.2026
EV-PB-11 issue 2 of 01.04.2021
EV-PB-12 issue 2 of 22.02.2022
EV-PB-13 issue 1 of 03.01.2023 EV-PB-14 issue 2 of 28.03.2023
EV-PB-14 issue 2 of 28.03.2023
EV-PB-17, issue 1 of 18.12.2023
EV-PB-18 issue 2 of 13.01.2026
EV-PB-4 issue 1 of 02.01.2017
EV-PB-4 issue 1 of 02.01.2017
EV-PB-5 issue 3 of 31.03.2025
EV-PB-7 issue 2 of 17.04.2018
EV-PB-8 issue 3 of 18.05.2021
EV-PB-9 issue 2 of 01.04.2021
ISO 12039:2019
ISO 13320:2020
ISO 15713:2006
NIOSH METHOD 1402, Issue 2, 15 August 1994
NIOSH METHOD 1450, Issue 3, 15 March 2003
NIOSH METHOD 2538, Issue 2, dated 15 August 1994
NIOSH Method 1010, Issue 2, 15 August 1994
NIOSH Method 1550, Issue 2, 15 August 1994
NIOSH Method 1550, Issue 2, 15 August 1994
NIOSH NMAM Fourth Edition 8/15/94, Method 1022, Issue 2
OSHA Method PV2009
PN-04009-11:2008
PN-75/Z-04037/03
PN-76/Z-04045/02
PN-76/Z-04045/02 and EV-IR/54 issue 1 of 31.01.2020
PN-78-Z-04112/01
PN-78-Z-04116.01
PN-78-Z-04118-01
PN-78-Z-04119/01
PN-79-Z-04057.01
PN-79/Z-04106.02 EV-IR-68 issue 1 of 18.12.2023 cl. 5.1
PN-81-Z-04134.02
PN-81-Z-04134.03
PN-83-Z-04110/02
PN-83/E-04040.03
PN-83/E-04040.03 EV-PB-2 issue 1 of 02.01.2017
PN-84-Z-04014/02 Principles and Methods of Assessing the Working Environment 2017, No. 1 (95), pp. 73–85
PN-86-Z-04152/02
PN-86-Z-04155/02
PN-87-Z-04178/02
PN-87/B-02156
PN-87/Z-04100.03
PN-89/Z-04023/02
PN-92-Z-04113/09
PN-92-Z-04224/02
PN-EN 12619:2013-05
PN-EN 13211+AC:2006
PN-EN 13284-1:2018-02
PN-EN 13284-1:2018-02 EV-IR-48 issue 2 of 26.03.2026
PN-EN 13649:2005
PN-EN 13649:2005 EV-IR-52 issue 1 of 14.10.2019
PN-EN 14253+A1:2011
PN-EN 14255-1:2010
PN-EN 14255-2:2010
PN-EN 14385:2005
PN-EN 14385:2005 EV-PB-16 issue 3 of 25.03.2024
PN-EN 14789:2017-04
PN-EN 14790:2017-04
PN-EN 14791:2017-04
PN-EN 14792:2017-04
PN-EN 15058:2017-04
PN-EN 1838:2025-05 excluding clauses: 5.1.3-5.1.9, 5.2.3-5.2.7, 5.3.4-5.3.8, 5.4.2, 6, 7, Method A
PN-EN 1911:2011
PN-EN ISO 11079:2008
PN-EN ISO 16911-1:2013-07 CEN/TR 17078:2017
PN-EN ISO 21877:2020-03
PN-EN ISO 5349-1:2004
PN-EN ISO 5349-2:2004
PN-EN ISO 5349-2:2004/A1:2015-11
PN-EN ISO 7243:2018-01
PN-EN ISO 7730:2006 +Ap2:2016-04
PN-EN ISO 9612:2025-11 excluding the methods covering strategies 2 and 3 – cl. 10 and 11
PN-ISO 10396:2001
PN-N-01307:1994
PN-T-05687:2002, cl. 2.5.4
PN-T-06580-3:2002 EV-PB-15 issue 1 of 18.12.2023
PN-Z-01339:2020-12
PN-Z-04007-2:1994
PN-Z-04007-2:1994 excluding cl. 7 EV-IR-53 issue 1 of 14.10.2019
PN-Z-04008-7:2002+Az1:2004
PN-Z-04015-12/Ap1:2001
PN-Z-04015-12:1996
PN-Z-04015-13:1996
PN-Z-04016-10:2005
PN-Z-04016-4:1998
PN-Z-04016-5:1998
PN-Z-04016-6:1998
PN-Z-04022-3:2001
PN-Z-04023-02:1989
PN-Z-04023-02:1998
PN-Z-04029-01:1981
PN-Z-04030-7:1994
PN-Z-04045-06:1982
PN-Z-04045-09:1992
PN-Z-04073-1:2014-08
PN-Z-04102-3:2013-10
PN-Z-04106-02:1979
PN-Z-04106-02:1979 EV-IR-72 issue 1 of 03.01.2025
PN-Z-04108-05:2006
PN-Z-04113-05:1989
PN-Z-04113-06:1986
PN-Z-04113-08:1992
PN-Z-04113-12:2005
PN-Z-04119-01:1978
PN-Z-04119-10:2008
PN-Z-04119-11:2008
PN-Z-04119-7:2006
PN-Z-04126-03:1987
PN-Z-04136-3:2003
PN-Z-04146-3:2006
PN-Z-04148-02:1985
PN-Z-04155-4:1996
PN-Z-04166-02:1986
PN-Z-04167-02:1986 Principles and Methods of Assessing the Working Environment 2010, No. 1 (63), pp. 169–175
PN-Z-04187-02:1988
PN-Z-04196-02:1988
PN-Z-04214-02:1990
PN-Z-04235-3:2001
PN-Z-04244-2:1996
PN-Z-04283:2001
PN-Z-04291:2003
PN-Z-04294:2001
PN-Z-04304:2003
PN-Z-04318:2005
PN-Z-04323:2004
PN-Z-04354:2005
PN-Z-04368:2008
PN-Z-04372:2009
PN-Z-04376:2010
PN-Z-04399:2011
PN-Z-04422:2010
PN-Z-04423:2011
PN-Z-04429:2011
PN-Z-04434:2011
PN-Z-04435:2011
PN-Z-04436:2011
PN-Z-04442:2023-10
PN-Z-04447:2014-06
PN-Z-04449:2014-06
PN-Z-04450:2014-08
PN-Z-04468:2015-10
PN-Z-04469:2025-02
PN-Z-04470:2015-10
PN-Z-04472:2015-10
PN-Z-04472:2015-10/Ap1:2015-12
PN-Z-04476:2016-10
PN-Z-04487:2017-10
PN-Z-04488:2017-10
PN-Z-04502:2019-10 EV-IR-72 issue 1 of 03.01.2025
PN-Z-04507:2022-05
PN-Z-04507:2022-05/Ap1:2022-08
PN-Z-04508:2022-05
PN-Z-04508:2022-05/Ap1:2022-08
PN-Z-71-Z-04041
Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 91–150
Principles and Methods of Assessing the Working Environment 1997, No. 16 pp. 39-42
Principles and Methods of Assessing the Working Environment 1997, No. 17 pp. 55-59
Principles and Methods of Assessing the Working Environment 1998, No. 19 pp. 160-164
Principles and Methods of Assessing the Working Environment 1999 No. 22, pp. 91-95
Principles and Methods of Assessing the Working Environment 1999, No. 22 pp. 91-95
Principles and Methods of Assessing the Working Environment 2004 No. 4(42) pp. 67-73
Principles and Methods of Assessing the Working Environment 2010, No. 1 (63), pp. 185–192
Principles and Methods of Assessing the Working Environment 2011 No. 1 (67), pp. 185-192
Principles and Methods of Assessing the Working Environment 2011, No. 1 (67), pp. 35–44
Principles and Methods of Assessing the Working Environment 2012, No. 4 (74), pp. 117–130
Principles and Methods of Assessing the Working Environment 2015 No. 4(86), pp. 191-202
Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 151–180
Principles and Methods of Assessing the Working Environment 2017, No. 2 (92), pp. 149–160
Principles and Methods of Assessing the Working Environment 2023, No. 3 (117), 95-122
Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 consolidated text Journal of Laws 2023 item 1706 excluding cl. F
based on NIOSH NMAM Fourth Edition 8/15/94 Method 2541, Issue 2 and OSHA Method 52