🇵🇱 ENVILAB-EKO Norbert Dąbrowski PL

PCA AB 1642 • Wrocław, Poland • 325 methods

EnvironmentMaterials & polymers

ENVILAB-EKO Norbert Dąbrowski is a laboratory accredited by PCA under number AB 1642 (Wrocław, Poland). Its accreditation scope covers 325 test methods in the following areas: Environment, Materials & polymers. Test objects include: Waste gases, Workplace environment − air − air samples collected on solid sorbent, Workplace environment − air − air samples collected on filters, Workplace environment − air − air samples collected into absorbing…. Most frequently used techniques: Gas chromatography with flame ionization detection (GC-FID), Flame atomic absorption spectrometry (FAAS), Spectrophotometric method.

At a glance

  • Accreditation number: PCA AB 1642
  • Methods in scope: 325
  • Types of test objects: 27
  • Techniques used: 24
  • City: Wrocław, Poland
Accreditation number
AB 1642
Accreditation body
PCA
Address
ul. bp. Bernarda Bogedaina 3, 50-514 Wrocław
City
Wrocław, Poland

What this laboratory tests (27)

Analytical techniques used (24)

Certificate information

Issue date
28.07.2026
Issue no.
23

Accreditation scope — test methods (325)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Workplace environment − air Sampling for the assessment of occupational exposure to: − dust agents
inhalable fraction respirable fraction − metals and their compounds, including inhalable fraction respirable fraction − organic substances, including inhalable fraction − inorganic substances, including inhalable fraction thoracic fraction respirable fraction − respirable man-made mineral fibres − respirable asbestos fibres
Personal dosimetry method PN-Z-04008-7:2002+Az1:2004
2 Workplace environment − air Sampling for the assessment of occupational exposure to: − organic substances − inorganic substances, including
inhalable fraction
Stationary method PN-Z-04008-7:2002+Az1:2004
3 Workplace environment − air Exposure index (calculated) PN-Z-04008-7:2002+Az1:2004
4 Workplace environment − air Concentration of harmful dust agents – inhalable fraction
apatites and phosphorites petroleum bitumen portland cement titanium dioxide natural graphite synthetic graphite kaolin amorphous and synthetic silica wood dusts flour dusts dusts not classified according to toxicity organic dusts of animal and plant origin, excluding wood and flour dusts carbon black calcium sulfate (VI) (gypsum) talc coal (hard, brown) calcium magnesium carbonate (dolomite) silicon carbide, non-fibrous Range (0,10 – 17,0) mg/m3
Gravimetric method PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08
5 Workplace environment − air Concentration of harmful dust agents – respirable fraction
apatites and phosphorites portland cement natural graphite amorphous and synthetic silica organic dusts of animal and plant origin, excluding wood and flour dusts diesel engine exhaust talc coal (hard, brown) Range (0,09 – 15,4) mg/m3
Gravimetric method PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08
6 Workplace environment − air Gas concentrations:
CO (2,5 – 117) mg/m3 Range (2,0 – 100) ppm NO (0,13 – 6,25) mg/m3 (0,1 – 5,0) ppm NO2 (0,19 – 2,3) mg/m3 (0,1 – 1,2) ppm
Electrochemical method EV-PB-1 issue 2 of 01.04.2021
7 Workplace environment − air Carbon dioxide concentration
Range (900 - 36000) mg/m3
Electrochemical method EV-PB-12 issue 2 of 22.02.2022
8 Workplace environment − noise A-weighted equivalent sound level Maximum A-weighted sound level
Range (30 - 135) dB C-weighted peak sound pressure level Range (40 - 137) dB
Direct measurement method PN-N-01307:1994 | PN-EN ISO 9612:2025-11 excluding the methods covering strategies 2 and 3 – cl. 10 and 11
9 Workplace environment − noise Noise exposure level referred to:
an 8-hour daily working time the average weekly working time (calculated)
PN-N-01307:1994 | PN-EN ISO 9612:2025-11 excluding the methods covering strategies 2 and 3 – cl. 10 and 11
10 Workplace environment – ultrasonic noise Equivalent sound pressure levels in one-third octave bands with centre frequencies from 10 kHz to 40 kHz Maximum sound pressure levels in one-third octave bands with centre frequencies from 10 kHz to 40 kHz
Range (49 - 158) dB
Direct measurement method PN-Z-01339:2020-12
11 Workplace environment – ultrasonic noise Equivalent sound pressure levels in third-octave bands with centre frequencies from 10 kHz to 40 kHz referred to:
an 8-hour daily working time the average weekly working time (calculated)
PN-Z-01339:2020-12
12 Rooms in residential, collective residence and public utility buildings − noise A-weighted equivalent sound level Maximum A-weighted sound level
Range (22 – 135) dB
Direct measurement method PN-87/B-02156
13 Rooms in residential, collective residence and public utility buildings − noise A-weighted equivalent sound level for reference time T (calculated) PN-87/B-02156
14 General environment – noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level
Range (25 - 135) dB
Direct measurement method Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 consolidated text Journal of Laws 2023 item 1706 excluding cl. F
15 General environment – noise from installations, equipment and industrial plants A-weighted equivalent sound level over the reference time T expressed by the indicators, LAeqD and LAeqN (calculated) Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 consolidated text Journal of Laws 2023 item 1706 excluding cl. F
16 Workplace environment - whole-body vibration Frequency-weighted r.m.s. vibration acceleration
Range (0,03 – 10) m/s2
Direct measurement method PN-EN 14253+A1:2011
17 Workplace environment - whole-body vibration Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the r.m.s. frequency-corrected vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz), Exposure lasting 30 minutes or less, expressed as the r.m.s. frequency-weighted vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz) (calculated) PN-EN 14253+A1:2011
18 Workplace environment - hand-arm vibration Frequency-weighted r.m.s. vibration acceleration
Range (0,56 – 60) m/s2
Direct measurement method PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11
19 Workplace environment - hand-arm vibration Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the vector sum of the r.m.s. frequency-corrected vibration accelerations determined for three directional components (ahwx, ahwy, ahwz), Exposure lasting 30 minutes or less, expressed as the vector sum of the r.m.s. frequency-weighted vibration accelerations determined for three directional components (ahwx, ahwy, ahwz) (calculated) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11
20 Workplace environment − hot microclimate Air temperature
Range (15 - 60) °C Natural wet bulb temperature Range (15 - 60) °C Black globe temperature Range (15 - 60) °C
Direct measurement method PN-EN ISO 7243:2018-01
21 Workplace environment − hot microclimate WBGT index, WBGTeff index (calculated) PN-EN ISO 7243:2018-01
22 Workplace environment − cold microclimate Air temperature
Range (- 30,0 - 10,0) °C Black globe temperature Range (- 30,0 - 10,0) °C Air humidity Range (20 - 90) % Air velocity Range (0,15 - 1,0) m/s
Direct measurement method PN-EN ISO 11079:2008
23 Workplace environment − cold microclimate IREQmin index, IREQneutral index, tWC index (calculated) PN-EN ISO 11079:2008
24 Workplace environment - moderate microclimate Air temperature
Range (10 - 30) °C Black globe temperature Range (10 - 40) °C Air humidity Range (20 - 90) % Air velocity Range (0,15 - 1,0) m/s
Direct measurement method PN-EN ISO 7730:2006 +Ap2:2016-04
25 Workplace environment - moderate microclimate PMV index, PPD index (calculated) PN-EN ISO 7730:2006 +Ap2:2016-04
26 Workplace environment - energy expenditure Air temperature
Range (0 - 40) ̊C Air flow Range (10 - 60) dm3/min
Direct measurement method EV-PB-8 issue 3 of 18.05.2021
27 Workplace environment - energy expenditure Energy expenditure (calculated) EV-PB-8 issue 3 of 18.05.2021
28 Workplace environment − indoor electric lighting Illuminance
Range (5 - 10000) lx
Direct measurement method PN-83/E-04040.03 EV-PB-2 issue 1 of 02.01.2017
29 Workplace environment − indoor electric lighting Illuminance uniformity (calculated) PN-83/E-04040.03 EV-PB-2 issue 1 of 02.01.2017
30 Workplace environment − outdoor electric lighting Illuminance
Range (0,5 - 10000) lx
Direct measurement method PN-83/E-04040.03
31 Workplace environment − outdoor electric lighting Illuminance uniformity (calculated) PN-83/E-04040.03
32 Workplace environment − emergency lighting Illuminance
Range (0,5 - 500) lx
Direct measurement method PN-EN 1838:2025-05 excluding clauses: 5.1.3-5.1.9, 5.2.3-5.2.7, 5.3.4-5.3.8, 5.4.2, 6, 7, Method A
33 Workplace environment − emergency lighting Ratio of minimum to maximum illuminance (calculated) PN-EN 1838:2025-05 excluding clauses: 5.1.3-5.1.9, 5.2.3-5.2.7, 5.3.4-5.3.8, 5.4.2, 6, 7, Method A
34 Workplace environment − emergency lighting Emergency lighting switch-on time
Range (1 - 80) s
PN-EN 1838:2025-05 excluding clauses: 5.1.3-5.1.9, 5.2.3-5.2.7, 5.3.4-5.3.8, 5.4.2, 6, 7, Method A
35 Workplace environment − non-laser optical radiation Effective irradiance UVA, UVB and UVC in the spectral range (180 ÷ 400) nm
Range (0,10x10-3 – 39,99) W/m2
Direct measurement method (method A) PN-EN 14255-1:2010
36 Workplace environment − non-laser optical radiation Effective radiant exposure to hazardous ultraviolet in the spectral range (180 ÷ 400) nm (calculated) PN-EN 14255-1:2010
37 Workplace environment − non-laser optical radiation UVA irradiance in the spectral range (315 ÷ 400) nm
Range (0,010 – 3,999x103) W/m2
Direct measurement method (method M) PN-EN 14255-1:2010
38 Workplace environment − non-laser optical radiation Radiant exposure of UVA radiation in the spectral range (315 ÷ 400) nm (calculated) PN-EN 14255-1:2010
39 Workplace environment − non-laser optical radiation Effective irradiance VIS in the spectral range (300÷700) nm
Range (1x10-3 – 399,9)
Direct measurement method (method O) PN-EN 14255-2:2010
40 Workplace environment − non-laser optical radiation Effective radiance of VIS radiation in the spectral range (300÷700) nm (calculated) PN-EN 14255-2:2010
41 Workplace environment − non-laser optical radiation Irradiance of VIS, IRA and IRB in the spectral range (380 ÷ 3000) nm
Range (1 – 3999) W/m2
Direct measurement method (method X) PN-EN 14255-2:2010
42 Workplace environment − non-laser optical radiation Radiant exposure for VIS, IRA, IRB in the spectral range (380 ÷ 3000) nm (calculated) PN-EN 14255-2:2010
43 Workplace environment − non-laser optical radiation Effective irradiance for VIS, IRA in the spectral range (380÷1400) nm
Range (1x10-3 – 3,999x103) W/m2
Direct measurement method PN-T-05687:2002, cl. 2.5.4
44 Workplace environment − non-laser optical radiation Effective radiance for, VIS, IRA in the spectral range (380÷1400) nm (calculated) PN-T-05687:2002, cl. 2.5.4
45 Workplace environment − non-laser optical radiation Effective irradiance for IRA in the spectral range (780÷1400) nm
Range (1x10-3 – 3,999x103) W/m2
Direct measurement method PN-T-05687:2002, cl. 2.5.4
46 Workplace environment − non-laser optical radiation Effective radiance for, IRA in the spectral range (780÷1400) nm (calculated) PN-T-05687:2002, cl. 2.5.4
47 Workplace environment - electromagnetic field Electric field strength in the frequency band: 10 Hz – 400 kHz, 1 GHz – 3 GHz
Range (1– 350) V/m
Direct measurement method PN-T-06580-3:2002 EV-PB-15 issue 1 of 18.12.2023
48 Workplace environment - electromagnetic field Magnetic field strength in the frequency range: 10Hz - 400kHz
Range (4 – 8000) A/m
Direct measurement method PN-T-06580-3:2002 EV-PB-15 issue 1 of 18.12.2023
49 Workplace environment - electromagnetic field Magnetic field strength:
in the frequency range from 1 GHz up to 3 GHz (calculated)
PN-T-06580-3:2002 EV-PB-15 issue 1 of 18.12.2023
50 Workplace environment - electromagnetic field Magnetic field strength in the frequency range: 0 Hz
Range 4 A/m – 800 kA/m
Direct measurement method PN-T-06580-3:2002 EV-PB-15 issue 1 of 18.12.2023
51 Workplace environment - electromagnetic field in the workspace from magnetotherapy devices Magnetic field strength:
in the frequency range 20 Hz – 50 Hz Range (4 – 8000) A/m
Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the legally regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (consolidated text: Journal of Laws of 2018, item 331).
Direct measurement method (simplified) Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 151–180
52 Workplace environment - electromagnetic field in the work space originating from power systems and AC electrical supply installations in the power industry Electric field strength in the frequency range: 10 - 400 kHz
Range 100 V/m – 50 kV/m
Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the legally regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (consolidated text: Journal of Laws of 2018, item 331).
Direct measurement method Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 91–150
53 Workplace environment - electromagnetic field in the work space originating from power systems and AC electrical supply installations in the power industry Magnetic field strength in the frequency range 10 - 400 kHz
Range 4 A/m – 800 kA/m
Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the legally regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (consolidated text: Journal of Laws of 2018, item 331).
Direct measurement method Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 91–150
54 Workplace environment − air − air samples collected into absorbing solutions Ammonia concentration/content
Range (1,2 - 60) mg/m3 Range (0,006 - 0,3) mg in the sample
Spectrophotometric method PN-Z-71-Z-04041
55 Workplace environment − air − air samples collected into absorbing solutions Hydrogen sulphide concentration/content
Range (0,5 - 28) mg/m3 Range (0,010 - 0,160) mg in the sample
Spectrophotometric method PN-Z-04015-13:1996
56 Workplace environment − air − air samples collected into absorbing solutions Nitrogen monoxide concentration/content
Range (0,29 - 23) mg/m3 Range (0,23 – 18,4) ppm Range (0,0013 - 0,052) mg in the sample
Spectrophotometric method PN-04009-11:2008
57 Workplace environment − air − air samples collected into absorbing solutions Nitrogen dioxide concentration/content
Range (0,089 – 7,1) mg/m3 Range (0,05 – 3,7) ppm Range (0,00040 - 0,016) mg in the sample
Spectrophotometric method PN-04009-11:2008
58 Workplace environment − air − air samples collected into absorbing solutions Concentration/content of nitric acid
Range (0,120 – 9,7) mg/m3 Range (0,00055 - 0,022) mg in the sample (calculated)
PN-04009-11:2008
59 Workplace environment − air − air samples collected into absorbing solutions Chlorine concentration/content
Range (0,065 – 5,0) mg/m3 Range (0,00026 - 0,0050) mg in the sample
Spectrophotometric method PN-75/Z-04037/03
60 Workplace environment − air − air samples collected into absorbing solutions Formaldehyde concentration/content
Range (0,13 – 6,6) mg/m3 Range (0,0010 - 0,040) mg in the sample
Spectrophotometric method PN-76/Z-04045/02
61 Workplace environment − air − air samples collected into absorbing solutions Ozone concentration/content
Range (0,0150 – 0,450) mg/m3 Range (0,0010 - 0,0180) mg in the sample
Spectrophotometric method PN-Z-04007-2:1994
62 Workplace environment − air − air samples collected into absorbing solutions Concentration/content of tetraphosphorus decaoxide
Range (0,050 – 5,0) mg/m3 Range (0,0010 - 0,10) mg in the sample
Spectrophotometric method PN-Z-04073-1:2014-08
63 Workplace environment − air − air samples collected into absorbing solutions Concentration/content of phosphoric acid
Range (0,0690 – 6,9) mg/m3 Range (0,00140 - 0,130) mg in the sample (calculated)
PN-Z-04073-1:2014-08
64 Workplace environment − air − air samples collected on solid sorbent Acetone concentration/content
Range (0,10 – 2000) mg/m3 Range (0,0010 – 2,4) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-79-Z-04057.01
65 Workplace environment − air − air samples collected on solid sorbent Concentration/content of xylene – mixture of isomers 1,2; 1,3; 1,4
m-xylene Range (0,0670-600) mg/m3 Range (0,0010 – 3,0) mg in the sample o-xylene Range (0,0670-620) mg/m3 Range (0,0010 – 3,10) mg in the sample p-xylene Range (0,0670-600) mg/m3 Range (0,0010 – 3,00) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-78-Z-04116.01
66 Workplace environment − air − air samples collected on solid sorbent Sum of contents of xylene – mixture of isomers 1,2; 1,3; 1,4 (calculated)
Range (0,0670-1820) mg/m3 Range (0,0010 – 9,10) mg in the sample
PN-78-Z-04116.01
67 Workplace environment − air − air samples collected on solid sorbent Ethanol concentration/content
Range (0,050–4537) mg/m3 Range (0,0010 – 16,3) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) EV-PB-4 issue 1 of 02.01.2017
68 Workplace environment − air − air samples collected on solid sorbent Butan-1-ol concentration/content
Range (0,050 – 569) mg/m3 Range (0,0010 – 4,10) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-89/Z-04023/02
69 Workplace environment − air − air samples collected on solid sorbent Concentration / content of 2-methylpropan-1-ol
Range (0,139 – 1708) mg/m3 Range (0,001 – 4,10) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-86-Z-04155/02
70 Workplace environment − air − air samples collected on solid sorbent Ethyl acetate concentration/content
Range (0,0670-2441) mg/m3 Range (0,02 – 667) ppm Range (0,0010-12,20) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-78-Z-04119/01
71 Workplace environment − air − air samples collected on solid sorbent Concentration/content of n-butyl acetate
Range (0,0670-1138) mg/m3 Range (0,0010-4,10) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-78-Z-04119/01
72 Workplace environment − air − air samples collected on solid sorbent Toluene concentration/content
Range (0,050-569) mg/m3 Range (0,0010-4,10) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) Principles and Methods of Assessing the Working Environment 2011, No. 1 (67), pp. 35–44
73 Workplace environment − air − air samples collected on solid sorbent 2-butoxyethanol concentration/content
Range (0,050-569) mg/m3 Range (0,0010-4,10) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) EV-PB-4 issue 1 of 02.01.2017 | PN-Z-04023-02:1998
74 Workplace environment − air − air samples collected on solid sorbent Benzene concentration/content
Range (0,050-333) mg/m3 Range (0,015 – 102,7) ppm Range (0,0010-2,40) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04016-10:2005
75 Workplace environment − air − air samples collected on solid sorbent Extraction naphtha concentration/content
Range (24,0 - 2083) mg/m3 Range (0,48 - 15) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-81-Z-04134.02 | NIOSH Method 1550, Issue 2, 15 August 1994
76 Workplace environment − air − air samples collected on solid sorbent White spirit concentration/content
Range (16 – 1388) mg/m3 Range (0,32 - 10) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-81-Z-04134.03 | NIOSH Method 1550, Issue 2, 15 August 1994
77 Workplace environment − air − air samples collected on solid sorbent Styrene concentration/content
Range (0,010-569) mg/m3 Range (0,0010-4,10) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-86-Z-04152/02
78 Workplace environment − air − air samples collected on solid sorbent Methyl methacrylate concentration/content
Range (0,10-569) mg/m3 Range (0,0010-4,10) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-92-Z-04113/09
79 Workplace environment − air − air samples collected on solid sorbent Ethylbenzene concentration/content
Range (0,050-1128) mg/m3 Range (0,0010-8,10) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) Principles and Methods of Assessing the Working Environment 2011, No. 1 (67), pp. 35–44
80 Workplace environment − air − air samples collected on solid sorbent Hexane concentration/content
Range (0,10-569) mg/m3 Range (0,0010-4,10) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04136-3:2003
81 Workplace environment − air − air samples collected on solid sorbent Cyclohexanone concentration/content
Range (0,10-333) mg/m3 Range (0,0010-2,40) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04447:2014-06
82 Workplace environment − air − air samples collected on solid sorbent Cyclohexane concentration/content
Range (0,050-1124) mg/m3 Range (0,0010-8,10) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) Principles and Methods of Assessing the Working Environment 2011, No. 1 (67), pp. 35–44
83 Workplace environment − air − air samples collected on solid sorbent Heptane concentration/content
Range (0,139-6776) mg/m3 Range (0,0010-16,30) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) Principles and Methods of Assessing the Working Environment 2004 No. 4(42) pp. 67-73
84 Workplace environment − air − air samples collected on solid sorbent Vinyl acetate concentration/content
Range (0,10-333) mg/m3 Range (0,0010-2,40) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-87-Z-04178/02
85 Workplace environment − air − air samples collected on solid sorbent Acrylonitrile concentration/content
Range (0,050-500) mg/m3 Range (0,02 – 227) ppm Range (0,0010-3,60) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04113-12:2005
86 Workplace environment − air − air samples collected on solid sorbent Dichloromethane concentration/content
Range (0,10-569) mg/m3 Range (0,03 – 161) ppm Range (0,0010-4,10) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-83-Z-04110/02
87 Workplace environment − air − air samples collected on solid sorbent Concentration/content of trimethylbenzene – mixture of isomers:
1,2,3 trimethylbenzene Range (0,070-600) mg/m3 Range (0,0010-3,0) mg in the sample 1,2,4 trimethylbenzene Range (0,0670-620) mg/m3 Range (0,0010-3,10) mg in the sample 1,3,5 trimethylbenzene Range (0,0670-600) mg/m3 Range (0,0010-3,0) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04016-4:1998
88 Workplace environment − air − air samples collected on solid sorbent Sum of concentrations/contents of trimethylbenzene – mixture of isomers (1,2,3; 1,2,4; 1,3,5) (calculated)
Range (0,070 – 1820) mg/m3 Range (0,0010 – 9,10) mg in the sample
PN-Z-04016-4:1998
89 Workplace environment − air − air samples collected on solid sorbent Concentration/content of tetrahydrofuran
Range (0,0670-820) mg/m3 Range (0,0010-4,10) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) Principles and Methods of Assessing the Working Environment 2015 No. 4(86), pp. 191-202
90 Workplace environment − air − air samples collected on solid sorbent Concentration/content of butan-2-ol
Range (0,0670-1627) mg/m3 Range (0,0010-8,10) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04155-4:1996
91 Workplace environment − air − air samples collected on solid sorbent Propan-2-ol concentration/content
Range (0,20-7551) mg/m3 Range (0,0010-27,2) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-92-Z-04224/02
92 Workplace environment − air − air samples collected on solid sorbent Tetrachloroethene concentration/content
Range (0,10-569) mg/m3 Range (0,015 – 83) ppm Range (0,0010-4,10) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-78-Z-04118-01
93 Workplace environment − air − air samples collected on solid sorbent Concentration/content of buta-1,3-diene
Range (0,175 – 600) mg/m3 Range (0,08 – 267) ppm Range (0,00118 – 0,60) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-84-Z-04014/02 Principles and Methods of Assessing the Working Environment 2017, No. 1 (95), pp. 73–85
94 Workplace environment − air − air samples collected on solid sorbent Concentration/content of chloroethene
Range (0,5 - 60) mg/m3 Range (0,19 – 23) ppm Range (0,005 – 0,6) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-78-Z-04112/01
95 Workplace environment − air − air samples collected on solid sorbent Concentration / content of 1-methoxy-2-propanol
Range (0,050-569) mg/m3 Range (0,0010-4,10) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04354:2005
96 Workplace environment − air − air samples collected on solid sorbent Concentration/content of butan-2-one
Range (0,230-1250) mg/m3 Range (0,0010-3,0) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04449:2014-06
97 Workplace environment − air − air samples collected on solid sorbent Concentration/content of 2-ethoxyethanol
Range (0,0450 – 126) mg/m3 Range (0,01 – 33,7) ppm Range (0,00090 – 0,91) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04023-02:1989
98 Workplace environment − air − air samples collected on solid sorbent 4-methylpentan-2-one concentration/content
Range (0,050 – 600) mg/m3 Range (0,00070 – 3,00) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04372:2009
99 Workplace environment − air − air samples collected on solid sorbent Methyl acrylate concentration/content
Range (0,120 – 680) mg/m3 Range (0,00120 – 4,90) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04113-05:1989
100 Workplace environment − air − air samples collected on solid sorbent Concentration / content of isopentane (2-methylbutane)
Range (0,240 – 6777) mg/m3 Range (0,00070 – 6,10) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04376:2010
101 Workplace environment − air − air samples collected on solid sorbent Concentration/content of butyl methacrylate
Range (0,0740 – 920) mg/m3 Range (0,00110 – 4,60) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04283:2001
102 Workplace environment − air − air samples collected on solid sorbent Concentration/content of methylcyclohexane
Range (0,0750 – 3375) mg/m3 Range (0,00150 – 24,3) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) Principles and Methods of Assessing the Working Environment 2011 No. 1 (67), pp. 185-192
103 Workplace environment − air − air samples collected on solid sorbent Concentration / content of 2-butoxyethyl acetate
Range (0,050 – 416) mg/m3 Range (0,000710 – 1,50) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04304:2003
104 Workplace environment − air − air samples collected on solid sorbent Concentration / content of 2-ethoxyethyl acetate
Range (0,110 – 470) mg/m3 Range (0,02 – 86) ppm Range (0,00110 – 4,70) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04023-02:1989
105 Workplace environment − air − air samples collected on solid sorbent Concentration / content of 2-methoxy-1-methylethyl acetate
Range (0,150 – 3291) mg/m3 Range (0,001450 – 23,70) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04119-10:2008
106 Workplace environment − air − air samples collected on solid sorbent Concentration / content of 2-methoxyethyl acetate
Range (0,090 – 513) mg/m3 Range (0,02 – 104,7) ppm Range (0,00090 – 3,70) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) Principles and Methods of Assessing the Working Environment 2010, No. 1 (63), pp. 185–192
107 Workplace environment − air − air samples collected on solid sorbent Isobutyl acetate concentration/content
Range (0,110 – 2527) mg/m3 Range (0,00110 – 18,20) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04119-11:2008
108 Workplace environment − air − air samples collected on solid sorbent Methyl acetate concentration/content
Range (0,080 – 1820) mg/m3 Range (0,00110 – 9,10) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04119-01:1978
109 Workplace environment − air − air samples collected on solid sorbent Concentration/content of propyl acetate
Range (0,090 – 3020) mg/m3 Range (0,00090 – 15,10) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04119-11:2008
110 Workplace environment − air − air samples collected on solid sorbent Concentration/content of ethyltoluene (mixture of isomers):
2-ethyltoluene 3-ethyltoluene 4-ethyltoluene Range (0,067 – 600,000) mg/m3 Range (0,001 – 3,0) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04016-5:1998
111 Workplace environment − air − air samples collected on solid sorbent Sum of concentrations/contents of ethyltoluene (mixture of isomers) (calculated)
Range (0,0670-1800) mg/m3 Range (0,0010 – 9,0) mg in the sample
PN-Z-04016-5:1998
112 Workplace environment − air − air samples collected on solid sorbent Pentane concentration/content
Range (0,340 – 9089) mg/m3 Range (0,0010 – 16,4) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04318:2005
113 Workplace environment − air − air samples collected on solid sorbent Octane concentration/content
Range (0,10 – 2277) mg/m3 Range (0,0010 – 4,10) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04166-02:1986
114 Workplace environment − air − air samples collected on solid sorbent Phenol concentration/content
Range (0,0670 – 920) mg/m3 Range (0,0010 – 4,6) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) Principles and Methods of Assessing the Working Environment 1999 No. 22, pp. 91-95
115 Workplace environment − air − air samples collected on solid sorbent Formaldehyde concentration/content
Range (0,0280 – 14) mg/m3 Range (0,0010 – 0,103) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) EV-IR-52 issue 1 of 14.10.2019 | based on NIOSH NMAM Fourth Edition 8/15/94 Method 2541, Issue 2 and OSHA Method 52
116 Workplace environment − air − air samples collected on solid sorbent Concentration / content of 4-hydroxy-4-methylpentan-2-one (diacetone alcohol)
Range (0,060 – 1027) mg/m3 Range (0,00090 – 7,40) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04368:2008
117 Workplace environment − air − air samples collected on solid sorbent Concentration/content of isopropyl acetate
Range (0,060 – 2111) mg/m3 Range (0,00090 – 15,20) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04119-7:2006
118 Workplace environment − air − air samples collected on solid sorbent Chlorobenzene concentration/content
Range (0,110 – 861) mg/m3 Range (0,00160 – 6,20) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04022-3:2001
119 Workplace environment − air − air samples collected on solid sorbent Concentration/content of chloroform
Range (0,40 – 500) mg/m3 Range (0,00120 – 0,60) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04187-02:1988
120 Workplace environment − air − air samples collected on solid sorbent Concentration/content of butyl acrylate
Range (0,120 – 333) mg/m3 Range (0,00120 – 2,4) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04113-06:1986
121 Workplace environment − air − air samples collected on solid sorbent Concentration/content of cumene (isopropylbenzene)
Range (0,070 – 569) mg/m3 Range (0,00100 – 4,10) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04016-6:1998
122 Workplace environment − air − air samples collected on solid sorbent Concentration / content of epichlorohydrin (1-chloro-2,3-epoxypropane)
Range (0,024 – 527) mg/m3 Range (0,01 – 137) ppm Range (0,000940 – 3,80) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04029-01:1981 | NIOSH Method 1010, Issue 2, 15 August 1994
123 Workplace environment − air − air samples collected on solid sorbent Concentration/content of 2-(2-butoxyethoxy) ethanol
Range (0,150 – 637) mg/m3 Range (0,00450 – 4,59) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04399:2011
124 Workplace environment − air − air samples collected on solid sorbent Ethylene glycol concentration/content
Range (0,210 – 444) mg/m3 Range (0,00650 – 3,20) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) Principles and Methods of Assessing the Working Environment 1997, No. 17 pp. 55-59
125 Workplace environment − air − air samples collected on solid sorbent Concentration/content of 2-methoxyethanol
Range (0,10 – 430) mg/m3 Range (0,03 – 136) ppm Range (0,0030 – 3,1) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04167-02:1986 Principles and Methods of Assessing the Working Environment 2010, No. 1 (63), pp. 169–175
126 Workplace environment − air − air samples collected on solid sorbent Cresol concentration/content – mixture of isomers
Range (0,340 – 350) mg/m3 Range (0,00170 – 0,42) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) Principles and Methods of Assessing the Working Environment 1999, No. 22 pp. 91-95
127 Workplace environment − air − air samples collected on solid sorbent Acrylic acid concentration/content
Range (0,67 – 722) mg/m3 Range (0,22 – 242) ppm Range (0,020 – 5,2) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04113-08:1992
128 Workplace environment − air − air samples collected on solid sorbent Trichloroethene concentration/content
Range (0,040 – 1138) mg/m3 Range (0,0010 – 8,20) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) NIOSH NMAM Fourth Edition 8/15/94, Method 1022, Issue 2
129 Workplace environment − air − air samples collected on solid sorbent Methanol concentration/content
Range (0,32 – 400) mg/m3 Range (0,0012 – 0,3) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04476:2016-10
130 Workplace environment − air − air samples collected on solid sorbent Acetic acid concentration/content
Range (0,021 – 138) mg/m3 Range (0,01 – 55) ppm Range (0,001 – 1,00) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04323:2004
131 Workplace environment − air − air samples collected on solid sorbent Concentration/content of propan-1-ol
Range (0,220 – 840) mg/m3 Range (0,00110 – 4,20) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) Principles and Methods of Assessing the Working Environment 1998, No. 19 pp. 160-164
132 Workplace environment − air − air samples collected on solid sorbent Concentration / content of furfural
Range (0,110 – 210) mg/m3 Range (0,00110 – 2,10) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04045-09:1992
133 Workplace environment − air − air samples collected on solid sorbent Sevoflurane concentration/content
Range (3,20 – 200) mg/m3 Range (0,0160 – 1,0) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04429:2011
134 Workplace environment − air − air samples collected on solid sorbent Concentration/content of desflurane
Range (3,20 – 200) mg/m3 Range (0,0160 – 1,0) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04422:2010
135 Workplace environment − air − air samples collected on solid sorbent Kerosene concentration/content
Range (1,850 – 625) mg/m3 Range (0,0370 – 4,50) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) NIOSH Method 1550, Issue 2, 15 August 1994
136 Workplace environment − air − air samples collected on solid sorbent Concentration/content of acrylaldehyde (acrolein)
Range (0,0040– 4,10) mg/m3 Range (0,01 – 1,76) ppm Range (0,000240 – 0,030) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04045-06:1982
137 Workplace environment − air − air samples collected on solid sorbent Concentration/content of acetonitrile
Range (4,7 – 300) mg/m3 Range (0,047 – 1,5) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04244-2:1996
138 Workplace environment − air − air samples collected on solid sorbent Concentration/content of acetaldehyde
Range (0,083 – 200) mg/m3 Range (0,0010 – 0,6) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) NIOSH METHOD 2538, Issue 2, dated 15 August 1994
139 Workplace environment − air − air samples collected on solid sorbent Concentration/content of cyclohexanol
Range (0,97 – 496) mg/m3 Range (0,0098 – 5) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) NIOSH METHOD 1402, Issue 2, 15 August 1994
140 Workplace environment − air − air samples collected on solid sorbent Concentration/content of phenylmethanol (benzyl alcohol)
Range (0,25 – 500) mg/m3 Range (0,0059 – 12) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) OSHA Method PV2009
141 Workplace environment − air − air samples collected on solid sorbent Concentration / content of amyl acetate (pentyl acetate)
Range (3,9 – 1000) mg/m3 Range (0,039 – 5) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) NIOSH METHOD 1450, Issue 3, 15 March 2003
142 Workplace environment − air − air samples collected on solid sorbent Concentration / content of isoamyl acetate (isopentyl acetate)
Range (3,9 – 1000) mg/m3 Range (0,039 – 5) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) NIOSH METHOD 1450, Issue 3, 15 March 2003
143 Workplace environment − air − air samples collected on solid sorbent Concentration / content of 2-ethylhexan-1-ol
Range (0,42 – 260) mg/m3 Range (0,010 – 1,3) mg in the sample Range (0,08 – 48) ppm
Gas chromatography with flame ionization detection (GC-FID) Principles and Methods of Assessing the Working Environment 2017, No. 2 (92), pp. 149–160
144 Workplace environment − air − air samples collected on solid sorbent Concentration / content of 2-furylmethanol
Range (1,9 – 240) mg/m3 Range (0,019 – 1,2) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04214-02:1990
145 Workplace environment − air − air samples collected on solid sorbent Isoflurane concentration/content
Range (1,25 – 80) mg/m 3 Range (0,00625 – 0,40) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04423:2011
146 Workplace environment − air − air samples collected on solid sorbent Concentration/content of enflurane
Range (1,25 – 80) mg/m3 Range (0,00625 – 0,40) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) Principles and Methods of Assessing the Working Environment 2023, No. 3 (117), 95-122
147 Workplace environment − air − air samples collected on filters Hydrogen chloride concentration/content
Range (0,50 – 10,0) mg/m3 Range (0,20 – 4,0) mg in the sample
Spectrophotometric method PN-Z-04450:2014-08
148 Workplace environment − air − air samples collected on filters Concentration/content of chromium (VI) compounds – expressed as Cr(VI)
Range (0,0005 – 0,027) mg/m3 Range (0,0005 – 0,020) mg in the sample
Spectrophotometric method PN-Z-04126-03:1987
149 Workplace environment − air − air samples collected on filters Concentration/content of ammonium chloride
Range (0,820 – 31,60) mg/m3 Range (0,0490 – 1,90) mg in the sample
Spectrophotometric method Principles and Methods of Assessing the Working Environment 1997, No. 16 pp. 39-42
150 Workplace environment − air − air samples collected on filters Concentration/content of sodium heptaoxotetraborate decahydrate (10 hydrate)
inhalable fraction Range (0,050 – 67) mg/m3 Range (0,0480 – 2,0) mg in the sample
Spectrophotometric method PN-Z-04235-3:2001
151 Workplace environment − air − air samples collected on filters Concentration / content of highly refined mineral oil, excluding metalworking fluids – inhalable fraction
Range (0,28 – 6,9) mg/m3 Range (0,2 – 5,0) mg in the sample
Fourier transform infrared spectrometry (FT-IR) PN-Z-04108-05:2006
152 Workplace environment − air − air samples collected on filters Concentration/content of crystalline silica (quartz, cristobalite) – respirable fraction
Range (0,010 – 0,2) mg/m3 Range (0,005 – 0,4) mg in the sample
Fourier transform infrared spectrometry (FT-IR) Principles and Methods of Assessing the Working Environment 2012, No. 4 (74), pp. 117–130
153 Work environment − air − air samples collected in a plastic bag General environment – waste gas samples - biogas samples - collected in a plastic bag Dinitrogen oxide (nitrous oxide) concentration
Range (3,7 – 3660) mg/m3 Range (2,0 – 1999,2) ppm
Fourier transform infrared spectrometry (FT-IR) EV-PB-18 issue 2 of 13.01.2026
154 Workplace environment − air − air samples collected into absorbing solutions Concentration/content of sulphur dioxide (SO2)
Range (0,123 – 6,40) mg/m3 Range (0,046 – 2,41) ppm Range (0,00160 – 0,0640) mg in the sample
Spectrophotometric method PN-Z-04015-12:1996 | PN-Z-04015-12/Ap1:2001
155 Workplace environment − air − air samples collected into absorbing solutions Formic acid concentration/content
Range (0,490 – 16,60) mg/m3 Range (0,00625 – 0,20) mg in the sample
Spectrophotometric method PN-Z-04196-02:1988
156 Workplace environment − air − air samples collected into absorbing solutions Concentration / content of hydrazine
Range (0,00130 – 0,040) mg/m3 Range (0,001 – 0,03) ppm Range (0,0000260 – 0,00080) mg in the sample
Spectrophotometric method PN-Z-04148-02:1985
157 Workplace environment − air − air samples collected on filters Concentration/Content of iron oxides – calculated as Fe iron (III) oxide, iron (II) oxide, triiron tetraoxide
inhalable fraction Range (0,034 – 25,0) mg/m3 Range (0,025 – 10,0) mg in the sample respirable fraction Range (0,032 – 25,0) mg/m3 Range (0,025 – 10,0) mg in the sample
Flame atomic absorption spectrometry (FAAS) PN-Z-04469:2025-02
158 Workplace environment − air − air samples collected on filters Concentration/content of manganese and its inorganic compounds – expressed as Mn
inhalable fraction Range (0,0014 – 0,80) mg/m3 Range (0,0010 – 0,60) mg in the sample respirable fraction Range (0,0013 – 0,75) mg/m3 Range (0,0010 – 0,60) mg in the sample
Flame atomic absorption spectrometry (FAAS) PN-Z-04472:2015-10 | PN-Z-04472:2015-10/Ap1:2015-12
159 Workplace environment − air − air samples collected on filters Concentration/content of cadmium and its inorganic compounds – calculated as Cd
inhalable fraction Range (0,00010 – 0,0078 ) mg/m3 Range (0,00010 – 0,0075) mg in the sample
Flame atomic absorption spectrometry (FAAS) PN-Z-04102-3:2013-10
160 Workplace environment − air − air samples collected on filters Metallic nickel concentration/content
Range (0,0014 – 0,694) mg/m3 Range (0,0010– 0,50) mg in the sample
Flame atomic absorption spectrometry (FAAS) PN-Z-04502:2019-10 EV-IR-72 issue 1 of 03.01.2025
161 Workplace environment − air − air samples collected on filters Concentration/content of nickel compounds – calculated as Ni
respirable fraction Range (0,0014-0,69) mg/m3 Range (0,0010 – 0,50) mg in the sample inhalable fraction Range (0,0014-0,69) mg/m3 Range (0,0010 – 0,50) mg in the sample
Flame atomic absorption spectrometry (FAAS) PN-Z-04502:2019-10 EV-IR-72 issue 1 of 03.01.2025
162 Workplace environment − air − air samples collected on filters Concentration/content of lead and its inorganic compounds expressed as Pb – inhalable fraction
Range (0,0021 – 0,111) mg/m3 Range (0,00150 – 0,080) mg in the sample
Flame atomic absorption spectrometry (FAAS) PN-Z-04487:2017-10
163 Workplace environment − air − air samples collected on filters Concentration/content of antimony and its inorganic compounds, except stibine – calculated as Sb
Range (0,028 – 1,38) mg/m3 Range (0,020 – 1,0) mg in the sample
Flame atomic absorption spectrometry (FAAS) PN-Z-04146-3:2006
164 Workplace environment − air − air samples collected on filters Concentration/content of zinc oxide – calculated as Zn
inhalable fraction Range (0,0017 – 25,0) mg/m3 Range (0,001250 – 10,4) mg in the sample
Flame atomic absorption spectrometry (FAAS) PN-87/Z-04100.03
165 Workplace environment − air − air samples collected on filters Sodium hydroxide concentration/content
Range (0,012 – 2,5) mg/m3 Range (0,0087 – 1,740) mg in the sample
Flame atomic absorption spectrometry (FAAS) PN-Z-04435:2011
166 Workplace environment − air − air samples collected on filters Potassium hydroxide concentration/content
Range (0,010 – 2,5) mg/m3 Range (0,00720 – 1,20) mg in the sample
Flame atomic absorption spectrometry (FAAS) PN-Z-04436:2011
167 Workplace environment − air − air samples collected on filters Calcium oxide concentration/content
inhalable fraction: Range (0,10 – 15,0) mg/m3 Range (0,07 – 4,60) mg in the sample respirable fraction: Range (0,09 – 15,0) mg/m3 Range (0,07 – 4,60) mg in the sample
Flame atomic absorption spectrometry (FAAS) PN-Z-04442:2023-10
168 Workplace environment − air − air samples collected on filters Concentration/content of calcium carbonate
inhalable fraction: Range (0,22 – 25,8) mg/m3 Range (0,160 – 18,60) mg in the sample
Flame atomic absorption spectrometry (FAAS) PN-Z-04294:2001
169 Workplace environment − air − air samples collected on filters Magnesium oxide concentration/content
inhalable fraction Range (0,47 – 22,7) mg/m3 Range (0,340 – 16,4) mg in the sample
Flame atomic absorption spectrometry (FAAS) PN-Z-04470:2015-10
170 Workplace environment − air − air samples collected on filters Concentration/content of tin and its inorganic compounds, except stannane – calculated as Sn
inhalable fraction Range (0,174 – 4,16) mg/m3 Range (0,1250 – 3,0) mg in the sample
Flame atomic absorption spectrometry (FAAS) PN-Z-04488:2017-10
171 Workplace environment − air − air samples collected on filters Concentration/content of selenium and its compounds, except selane – calculated as Se
Range (0,0069 – 0,70) mg/m3 Range (0,0050 – 0,40) mg in the sample
Flame atomic absorption spectrometry (FAAS) PN-Z-04468:2015-10
172 Workplace environment − air − air samples collected on filters Concentration/content of cobalt and its inorganic compounds – calculated as Co
Range (0,0014 – 0,069) mg/m3 Range (0,0010 – 0,050) mg in the sample
Flame atomic absorption spectrometry (FAAS) PN-Z-04291:2003
173 Workplace environment − air − air samples collected on filters Concentration / content of metallic chromium and chromium compounds (chromium (II), chromium (III), chromium (VI)) – expressed as Cr
Range (0,010 – 1,38) mg/m3 Range (0,0075 – 1,0) mg in the sample
Flame atomic absorption spectrometry (FAAS) PN-Z-04434:2011
174 Workplace environment − air − air samples collected on filters Concentration/content of metallic chromium, chromium (II) compounds - expressed as Cr (II), chromium (III) compounds – expressed as Cr (III) Calculation method EV-PB-17, issue 1 of 18.12.2023
175 Workplace environment − air − air samples collected on filters Concentration/content of copper and its inorganic compounds – calculated as Cu
Range (0,0014 - 1,38) mg/m3 Range (0,0010 – 1,0) mg in the sample
Flame atomic absorption spectrometry (FAAS) PN-79/Z-04106.02 EV-IR-68 issue 1 of 18.12.2023 cl. 5.1
176 Workplace environment − air − air samples collected on filters Concentration/content of iron oxides – expressed as Fe iron (III) oxide, iron (II) oxide, triiron tetraoxide
inhalable fraction Range (0,0028 – 25,0) mg/m3 Range (0,0020 – 10,0) mg in the sample respirable fraction Range (0,0025 – 25,0) mg/m3 Range (0,0020 – 10,0) mg in the sample
Flame atomic absorption spectrometry (FAAS) PN-79/Z-04106.02 EV-IR-68 issue 1 of 18.12.2023 cl. 5.1
177 Workplace environment − air − air samples collected on filters Concentration/content of manganese and its inorganic compounds – expressed as Mn
inhalable fraction Range (0,0014 – 0,80) mg/m3 Range (0,0010 – 0,60) mg in the sample respirable fraction Range (0,0013–0,75) mg/m3 Range (0,0010 – 0,60) mg in the sample
Flame atomic absorption spectrometry (FAAS) PN-79/Z-04106.02 EV-IR-68 issue 1 of 18.12.2023 cl. 5.1
178 Workplace environment − air − air samples collected on filters Concentration / content of metallic chromium and chromium compounds (chromium (II), chromium (III), chromium (VI)) – expressed as Cr
Range (0,0083 – 1,11) mg/m3 Range (0,0060 – 0,80) mg in the sample
Flame atomic absorption spectrometry (FAAS) PN-Z-04106-02:1979
179 Workplace environment − air − air samples collected on filters Metallic nickel concentration/content
Range (0,0014 – 0,69) mg/m3 Range (0,0010 – 0,50) mg in the sample
Flame atomic absorption spectrometry (FAAS) PN-Z-04106-02:1979 EV-IR-72 issue 1 of 03.01.2025
180 Workplace environment − air − air samples collected on filters Concentration/content of nickel compounds – calculated as Ni
respirable fraction Range (0,0009 - 0,47) mg/m3 Range (0,0010 – 0,50) mg in the sample inhalable fraction Range (0,0014 - 0,69) mg/m3 Range (0,0010 – 0,50) mg in the sample
Flame atomic absorption spectrometry (FAAS) PN-Z-04106-02:1979 EV-IR-72 issue 1 of 03.01.2025
181 Waste gases Gas volume flow rate for dynamic pressures > 10 Pa
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Stagnation pressure method PN-Z-04030-7:1994
182 Waste gases Gas volume flow rate for velocity
Range (0,6 – 40) m/s
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Anemometric method PN-Z-04030-7:1994
183 Waste gases Sampling for determination of dust concentration
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
PN-Z-04030-7:1994
184 Waste gases Dust concentration
Range (0,001 – 21,9) g/m3
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Gravimetric method PN-Z-04030-7:1994
185 Waste gases Dust emission (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
PN-Z-04030-7:1994
186 Waste gases Oxygen concentration
Range (2,9 – 22,5) %
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Paramagnetic method (PMD) PN-ISO 10396:2001
187 Waste gases CO, CO2 concentration
CO (1,25 – 5467) mg/m3 CO2 (0,2 – 27,5) %
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Non-dispersive infrared spectrometry (NDIR) PN-ISO 10396:2001
188 Waste gases Emission of CO, CO2 (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
PN-ISO 10396:2001
189 Waste gases NO, NOx concentration
NO (1,4 – 3347) mg/m3 NOx (2,1 – 5125) mg/m3
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Chemiluminescence method (CLD) PN-ISO 10396:2001
190 Waste gases Emission of NO, NOx (NOx expressed as NO2) (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
PN-ISO 10396:2001
191 Waste gases SO2 concentration
Range (2,9 – 5358) mg/m3
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Non-dispersive infrared spectrometry (NDIR) PN-ISO 10396:2001
192 Waste gases SO2 emission (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
PN-ISO 10396:2001
193 Waste gases Sampling for determination of hydrogen chloride concentration
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
PN-EN 1911:2011
194 Waste gases Hydrogen chloride concentration/content
Range (0,130 – 231) mg/m3 Range (0,026 – 23,1) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Spectrophotometric method PN-EN 1911:2011
195 Waste gases HCl emission (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
PN-EN 1911:2011
196 Waste gases Sampling for determination of hydrogen fluoride concentration
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
ISO 15713:2006
197 Waste gases HF emission (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
ISO 15713:2006
198 Waste gases Sampling for determination of metal concentrations: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
PN-EN 14385:2005
199 Waste gases Gas volume flow rate for differential pressures > 5 Pa
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Differential pressure measurement method PN-EN ISO 16911-1:2013-07 CEN/TR 17078:2017
200 Waste gases Water vapour concentration (H2O)
Range (29 – 250) g/m3 Range (4,0 – 40,0) %
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Condensation-adsorption method PN-EN 14790:2017-04
201 Waste gases Oxygen concentration
Range (2,9 – 22,5) %
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Paramagnetic method (PMD) PN-EN 14789:2017-04
202 Waste gases CO2 concentration
Range (0,2 – 27,5) %
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Non-dispersive infrared spectrometry (NDIR) ISO 12039:2019
203 Waste gases CO2 emission (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
ISO 12039:2019
204 Waste gases CO concentration
Range (1,25 – 5467) mg/m3
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Non-dispersive infrared spectrometry (NDIR) PN-EN 15058:2017-04
205 Waste gases CO emission (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
PN-EN 15058:2017-04
206 Waste gases NO, NOx concentration
NO (1,4 – 3347) mg/m3 NOx (2,1 – 5125) mg/m3
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Chemiluminescence method (CLD) PN-EN 14792:2017-04
207 Waste gases Emission of NO, NOx (NOx expressed as NO2) (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
PN-EN 14792:2017-04
208 Waste gases Sampling for the determination of sulfur dioxide concentration
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
PN-EN 14791:2017-04
209 Waste gases Sulphur dioxide emission (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
PN-EN 14791:2017-04
210 Waste gases Concentration / content of metals
Cd (0,0010 – 20) mg/m3 Range (0,00010 – 10) mg in the sample Cr (0,00150 – 20) mg/m3 (0,0150 – 10) mg in the sample Co (0,00050 – 20) mg/m3 (0,0050 – 10) mg in the sample Cu (0,000250 – 20) mg/m3 (0,00250 – 10) mg in the sample Mn (0,000250 – 20) mg/m3 (0,00250 – 10) mg in the sample Ni (0,00050 – 20) mg/m3 (0,0050 – 10) mg in the sample Pb (0,000750 - 20) mg/m3 (0,00750 – 10) mg in the sample Sb (0,010 – 20) mg/m3 (0,10 – 10) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Flame atomic absorption spectrometry (FAAS) PN-EN 14385:2005
211 Waste gases Emission of metals: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
PN-EN 14385:2005
212 Waste gases Sampling for determination of total mercury concentration
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
PN-EN 13211+AC:2006
213 Waste gases Total mercury emission (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
PN-EN 13211+AC:2006
214 Waste gases Sampling for determination of the concentration of individual gaseous organic compounds
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
PN-EN 13649:2005
215 Waste gases Acetone concentration/content
Range (0,017 – 2733) mg/m3 Range (0,001 – 4,1) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005
216 Waste gases Concentration/content of xylene – mixture of isomers:
m-xylene Range (0,017 - 2733) mg/m3 Range (0,001 – 4,1) mg in the sample o-xylene Range (0,017 - 2733) mg/m3 Range (0,001 – 4,1) mg in the sample p-xylene Range (0,0170 - 2667) mg/m3 Range (0,001 – 4,0) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005
217 Waste gases Sum of xylene concentration/content – mixture of isomers (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
PN-EN 13649:2005
218 Waste gases Ethanol concentration/content
Range (0,017 – 2733) mg/m3 Range (0,001 – 4,1) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005
219 Waste gases Butan-1-ol concentration/content
Range (0,017 – 2733) mg/m3 Range (0,001 – 4,1) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005
220 Waste gases Concentration / content of 2-methylpropan-1-ol
Range (0,017 – 2733) mg/m3 Range (0,001 – 4,1) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005
221 Waste gases Ethyl acetate concentration/content
Range (0,017 – 2733) mg/m3 Range (0,001 – 4,1) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005
222 Waste gases Concentration/content of n-butyl acetate
Range (0,017 – 2733) mg/m3 Range (0,001 – 4,1) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005
223 Waste gases Toluene concentration/content
Range (0,017 – 2733) mg/m3 Range (0,001 – 4,1) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005
224 Waste gases 2-butoxyethanol concentration/content
Range (0,017 – 2733) mg/m3 Range (0,001 – 4,1) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005
225 Waste gases Benzene concentration/content
Range (0,017– 2733) mg/m3 Range (0,001 – 4,1) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005
226 Waste gases Styrene concentration/content
Range (0,017- 2733) mg/m3 Range (0,001 – 4,1) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005
227 Waste gases Methyl methacrylate concentration/content
Range (0,017 – 2733) mg/m3 Range (0,001 – 4,5) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005
228 Waste gases Ethylbenzene concentration/content
Range (0,017– 2733) mg/m3 Range (0,001 – 4,1) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005
229 Waste gases Cyclohexanone concentration/content
Range (0,017 – 2733) mg/m3 Range (0,001 – 4,1) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005
230 Waste gases Cyclohexane concentration/content
Range (0,017 – 2667) mg/m3 Range (0,001 – 4,0) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005
231 Waste gases Vinyl acetate concentration/content
Range (0,017 – 2733) mg/m3 Range (0,001 – 4,1) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005
232 Waste gases Acrylonitrile concentration/content
Range (0,017 – 2667) mg/m3 Range (0,001 – 4) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005
233 Waste gases Dichloromethane concentration/content
Range (0,017– 2733) mg/m3 Range (0,001 – 4,1) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005
234 Waste gases Concentration/content of trimethylbenzene – mixture of isomers
1, 2, 3 trimethylbenzene Range (0,017– 2667) mg/m3 Range (0,001 – 4) mg in the sample 1, 2, 4 trimethylbenzene Range (0,017 – 2733) mg/m3 Range (0,001 – 4,1) mg in the sample 1, 3, 5 trimethylbenzene Range (0,017 – 2733) mg/m3 Range (0,001 – 4,1) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005
235 Waste gases Sum of trimethylbenzene concentration/content – mixture of isomers (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
PN-EN 13649:2005
236 Waste gases Concentration/content of tetrahydrofuran
Range (0,017 – 2733) mg/m3 Range (0,001 – 4,1) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005
237 Waste gases Concentration/content of butan-2-ol
Range (0,017– 2733) mg/m3 Range (0,001 – 4,1) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005
238 Waste gases Propan-2-ol concentration/content
Range (0,017 – 3067) mg/m3 Range (0,001 – 4,6) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005
239 Waste gases Acetic acid concentration/content
Range (0,017 – 666) mg/m3 Range (0,001 – 1,00) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005
240 Waste gases Tetrachloroethene concentration/content
Range (0,017 – 2733) mg/m3 Range (0,001 – 4,1) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005
241 Waste gases Concentration/content of buta-1,3-diene
Range (0,020 – 400) mg/m3 Range (0,00118 – 0,60) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005
242 Waste gases Concentration/content of vinyl chloride
Range (0,13 – 60,1) mg/m3 Range (0,004 – 0,2) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005
243 Waste gases Concentration / content of 1-methoxy-2-propanol
Range (0,017– 2733) mg/m3 Range (0,001 – 4,1) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005
244 Waste gases Concentration/content of butan-2-one
Range (0,017 – 2733) mg/m3 Range (0,001 – 4,1) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005
245 Waste gases Concentration/content of aliphatic hydrocarbons:
pentane Range (0,017 – 2733) mg/m3 Range (0,001 – 4,1) mg in the sample hexane Range (0,017 – 2733) mg/m3 Range (0,001 – 4,1) mg in the sample heptane Range (0,017- 2733) mg/m3 Range (0,001 – 4,1) mg in the sample octane Range (0,017- 2733) mg/m3 Range (0,001 – 4,1) mg in the sample nonane Range (0,017- 2733) mg/m3 Range (0,001 – 4,1) mg in the sample decane Range (0,017- 2733) mg/m3 Range (0,001 – 4,1) mg in the sample undecane Range (0,017- 2733) mg/m3 Range (0,001 – 4,1) mg in the sample dodecane Range (0,017- 2733) mg/m3 Range (0,001 – 4,1) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005
246 Waste gases Sum of concentrations/contents of aliphatic hydrocarbons C5-C12 (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
PN-EN 13649:2005
247 Waste gases Concentration/content of ethyltoluene – mixture of isomers:
2-ethyltoluene Range (0,017- 2733) mg/m3 Range (0,001 – 4,1) mg in the sample 3-ethyltoluene Range (0,017- 2733) mg/m3 Range (0,001 – 4,1) mg in the sample 4-ethyltoluene Range (0,017- 2733) mg/m3 Range (0,001 – 4,1) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005
248 Waste gases Sum of ethyltoluene concentration/content (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
PN-EN 13649:2005
249 Waste gases Sum of aromatic hydrocarbon concentration/content (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
PN-EN 13649:2005
250 Waste gases Phenol concentration/content
Range (0,017 – 3067) mg/m3 Range (0,001 – 4,6) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005
251 Waste gases Concentration/content of cumene
Range (0,017 –2733) mg/m3 Range (0,001 – 4,1) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005
252 Waste gases Concentration/content of 2-ethoxyethanol
Range (0,0150 – 606) mg/m3 Range (0,00090 – 0,91) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005
253 Waste gases 4-methylpentan-2-one concentration/content
Range (0,0120 – 2000) mg/m3 Range (0,00070 – 3,0) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005
254 Waste gases Concentration/content of butyl acrylate
Range (0,020 – 1600) mg/m3 Range (0,00120 – 2,40) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005
255 Waste gases Methyl acrylate concentration/content
Range (0,020 – 3266) mg/m3 Range (0,00120 – 4,90) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005
256 Waste gases Concentration / content of isopentane (2-methylbutane)
Range (0,0120 – 4066) mg/m3 Range (0,00070 – 6,10) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005
257 Waste gases Concentration/content of butyl methacrylate
Range (0,0190 – 3066) mg/m3 Range (0,00110 – 4,60) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005
258 Waste gases Concentration/content of methylcyclohexane
Range (0,0250 – 16200) mg/m3 Range (0,00150 – 24,30) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005
259 Waste gases Concentration / content of 2-butoxyethyl acetate
Range (0,0120 – 1000) mg/m3 Range (0,000710 – 1,50) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005
260 Waste gases Concentration / content of 2-ethoxyethyl acetate
Range (0,0190 – 3133) mg/m3 Range (0,00110 – 4,70) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005
261 Waste gases Concentration / content of 2-methoxy-1-methylethyl acetate
Range (0,0250 – 15800) mg/m3 Range (0,00145 – 23,70) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005
262 Waste gases Concentration / content of 2-methoxyethyl acetate
Range (0,0150 – 2466) mg/m3 Range (0,00090 – 3,70) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005
263 Waste gases Isobutyl acetate concentration/content
Range (0,01840 – 12133) mg/m3 Range (0,00110 – 18,20) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005
264 Waste gases Methyl acetate concentration/content
Range (0,0190 – 6066) mg/m3 Range (0,00110 – 9,10) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005
265 Waste gases Concentration/content of propyl acetate
Range (0,0150 – 10066) mg/m3 Range (0,00090 – 15,10) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005
266 Waste gases Concentration / content of 4-hydroxy-4-methylpentan-2-one (diacetone alcohol)
Range (0,0150 – 4933) mg/m3 Range (0,00090 – 7,40) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005
267 Waste gases Concentration/content of isopropyl acetate
Range (0,0150 – 10133) mg/m3 Range (0,00090 – 15,20) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005
268 Waste gases Chlorobenzene concentration/content
Range (0,0270 – 4133) mg/m3 Range (0,00160 – 6,20) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005
269 Waste gases Concentration/content of chloroform
Range (0,020 – 400) mg/m3 Range (0,00120 – 0,60) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005
270 Waste gases n-Propylbenzene concentration/content
Range (0,0170 – 2733) mg/m3 Range (0,00100 – 4,10) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005
271 Waste gases Concentration/content of 1-ethoxypropan-2-ol
Range (0,0190 – 2866) mg/m3 Range (0,00100 – 4,30) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005
272 Waste gases Formaldehyde concentration/content
Range (0,01670 – 68) mg/m3 Range (0,0010 – 0,103) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005 EV-IR-52 issue 1 of 14.10.2019 | based on NIOSH NMAM Fourth Edition 8/15/94 Method 2541, Issue 2 and OSHA Method 52
273 Waste gases Concentration / content of epichlorohydrin (1-chloro-2,3-epoxypropane)
Range (0,0160 – 2533) mg/m3 Range (0,000940 – 3,80) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005
274 Waste gases Concentration/content of 2-(2-butoxyethoxy) ethanol
Range (0,075 – 3060) mg/m3 Range (0,00450 – 4,59) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005
275 Waste gases Ethylene glycol concentration/content
Range (0,11 – 2133) mg/m3 Range (0,00650 – 3,20) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005
276 Waste gases Concentration/content of 2-methoxyethanol
Range (0,050 – 2066) mg/m3 Range (0,0030 – 3,1) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005
277 Waste gases Cresol concentration/content – mixture of isomers
Range (0,029 – 280) mg/m3 Range (0,00170 – 0,42) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005
278 Waste gases Acrylic acid concentration/content
Range (0,33 – 3466) mg/m3 Range (0,020 – 5,2) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005
279 Waste gases Trichloroethene concentration/content
Range (0,017 – 5466) mg/m3 Range (0,0010 – 8,20) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005
280 Waste gases Methanol concentration/content
Range (0,02 – 200) mg/m3 Range (0,0012 – 0,3) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005
281 Waste gases Concentration/content of propan-1-ol
Range (0,01840 – 2800) mg/m3 Range (0,00110 – 4,20) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005
282 Waste gases Concentration/content of acetaldehyde
Range (0,01670 – 400) mg/m3 Range (0,00100 – 0,6) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005
283 Waste gases Concentration / content of furfural
Range (0,01840 – 1400) mg/m3 Range (0,00110 – 2,10) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005
284 Waste gases Concentration/content of acrylaldehyde (acrolein)
Range (0,0040 – 20,0) mg/m3 Range (0,000240 – 0,030) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005
285 Waste gases Concentration/content of acetonitrile
Range (0,79 – 1000) mg/m3 Range (0,047 – 1,5) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005
286 Waste gases Concentration/content of cyclohexanol
Range (0,17 – 3333) mg/m3 Range (0,0098 – 5) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005
287 Waste gases Concentration/content of phenylmethanol (benzyl alcohol)
Range (0,10 – 8000) mg/m3 Range (0,0059 – 12) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005
288 Waste gases Concentration / content of amyl acetate (pentyl acetate)
Range (0,65 – 3333) mg/m3 Range (0,039 – 5) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005
289 Waste gases Concentration / content of isoamyl acetate (isopentyl acetate)
Range (0,65 – 3333) mg/m3 Range (0,039 – 5) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005
290 Waste gases Concentration / content of 2-ethylhexan-1-ol
Range (0,17 – 866) mg/m3 Range (0,010 – 1,3) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005
291 Waste gases Concentration / content of 2-furylmethanol
Range (0,32 – 800) mg/m3 Range (0,019 – 1,2) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005
292 Waste gases Emission of individual gaseous organic compounds (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
PN-EN 13649:2005
293 Waste gases Concentration of organic substances in the form of gases and vapours expressed as total gaseous organic carbon
Range (8,0 - 1280) mg/m3
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
Continuous flame ionization detection method (FID) PN-EN 12619:2013-05
294 Waste gases Emission of organic substances in gaseous and vapour form expressed as total gaseous organic carbon (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law
PN-EN 12619:2013-05
295 Waste gases Sampling for determination of hydrogen sulphide concentration EV-PB-5 issue 3 of 31.03.2025
296 Waste gases Hydrogen sulphide emission (calculated) EV-PB-5 issue 3 of 31.03.2025
297 Waste gases Hydrogen sulphide concentration/content
Range (0,830 – 66,7) mg/m3 Range (0,050 – 2,0) mg in the sample
Spectrophotometric method EV-PB-7 issue 2 of 17.04.2018
298 Waste gases Dust sampling for the determination of PM 1, PM 2,5 and PM 10 concentration PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02 EV-IR-48 issue 2 of 26.03.2026
299 Waste gases Emission of PM 1, PM 2,5 and PM 10 dust (calculated) PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02 EV-IR-48 issue 2 of 26.03.2026
300 Waste gases Sampling for the determination of ozone concentration EV-PB-11 issue 2 of 01.04.2021
301 Waste gases Ozone concentration/content
Range (0,0150 – 0,450) mg/m3 Range (0,0010 – 0,0180) mg in the sample
Spectrophotometric method PN-Z-04007-2:1994 excluding cl. 7 EV-IR-53 issue 1 of 14.10.2019
302 Waste gases Ozone emission (calculated) EV-PB-11 issue 2 of 01.04.2021
303 Waste gases Sampling for determination of formaldehyde concentration EV-PB-11 issue 2 of 01.04.2021
304 Waste gases Formaldehyde concentration/content
Range (0,0670 – 66) mg/m3 Range (0,0040 – 0,40) mg in the sample
Spectrophotometric method PN-76/Z-04045/02 and EV-IR/54 issue 1 of 31.01.2020
305 Waste gases Formaldehyde emission (calculated) EV-PB-11 issue 2 of 01.04.2021
306 Waste gases Sampling for determination of sulfuric acid concentration EV-PB-10 issue 3 of 17.03.2026
307 Waste gases Sulfuric acid concentration/content
Range (0,0190 – 29,9) mg/m3 Range (0,20 – 5) mg in the sample
Spectrophotometric method EV-PB-10 issue 3 of 17.03.2026
308 Waste gases Sulfuric acid emission (calculated) EV-PB-10 issue 3 of 17.03.2026
309 Waste gases Sampling for determination of chromium (VI) concentration EV-PB-9 issue 2 of 01.04.2021
310 Waste gases Concentration/content of chromium (VI)
Range (0,0000910 – 0,0390) mg/m3 Range (0,00050 – 0,020) mg in the sample
Spectrophotometric method EV-PB-9 issue 2 of 01.04.2021
311 Waste gases Emission of chromium (VI) (calculated) EV-PB-9 issue 2 of 01.04.2021
312 Waste gases Sampling for determination of ammonia concentration PN-EN ISO 21877:2020-03
313 Waste gases Ammonia concentration/content
Range (0,05 – 400) mg/m3 Range (0,005 – 12) mg in the sample
Spectrophotometric method PN-EN ISO 21877:2020-03
314 Waste gases Ammonia emission (calculated) PN-EN ISO 21877:2020-03
315 Dust samples Proportion of dust fractions (particle size distribution) including PM 1; PM 2,5; PM 10
Range (0,1 – 3800) μm Range (0 – 100) %
Laser diffraction method ISO 13320:2020
316 Waste gases Sampling for determination of dust concentration PN-EN 13284-1:2018-02
317 Waste gases Dust concentration
Range (0,1 – 50) mg/m3
Gravimetric method PN-EN 13284-1:2018-02
318 Waste gases Dust emission (calculated) PN-EN 13284-1:2018-02
319 Waste gases Sampling for determination of metal concentrations: Zn, Fe, Sn PN-EN 14385:2005 EV-PB-16 issue 3 of 25.03.2024
320 Waste gases Concentration / content of metals
Zn (0,000250 – 20) mg/m3 Range (0,00250 – 10) mg in the sample Fe (0,00050 – 20) mg/m3 (0,0050 – 10) mg in the sample Sn (0,0250 – 20) mg/m3 (0,250 – 10) mg in the sample
Flame atomic absorption spectrometry (FAAS) PN-EN 14385:2005 EV-PB-16 issue 3 of 25.03.2024
321 Waste gases Emission of metals: Zn, Fe, Sn (calculated) PN-EN 14385:2005 EV-PB-16 issue 3 of 25.03.2024
322 Rooms intended for human occupancy – air Sampling for the determination of organic compound concentration EV-PB-14 issue 2 of 28.03.2023
323 Rooms intended for human occupancy: – air – air samples collected on sorbent tubes Concentration/Content:
acrylonitrile Range (2,0 – 4000) μg/m3 Range (0,0010 – 4,00) mg in the sample benzene Range (2,0 – 4000) μg/m3 Range (0,0010 – 4,00) mg in the sample buta-1,3-diene Range (9,0 – 4000) μg/m3 Range (0,0012 – 0,60) mg in the sample butan-1-ol (butyl alcohol) Range (2,0 – 4000) μg/m3 Range (0,0010 – 4,00) mg in the sample vinyl chloride Range (4,9 – 4000) μg/m3 Range (0,0007 – 0,70) mg in the sample chlorobenzene Range (3,2 – 4000) μg/m3 Range (0,0016 – 6,20) mg in the sample cyclohexane Range (2,0 – 4000) μg/m3 Range (0,0010 – 4,00) mg in the sample cyclohexanone Range (2,0 – 4000) μg/m3 Range (0,0010 – 4,00) mg in the sample ethylbenzene Range (2,0 – 4000) μg/m3 Range (0,0010 – 4,00) mg in the sample phenol Range (2,0 – 4000) μg/m3 Range (0,0010 – 4,50) mg in the sample formaldehyde Range (7,0 – 600) μg/m3 Range (0,0010 – 0,100) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) EV-PB-13 issue 1 of 03.01.2023 EV-PB-14 issue 2 of 28.03.2023
324 Rooms intended for human occupancy: – air – air samples collected on sorbent tubes Concentration/Content:
ethylene glycol Range (13,0 – 4000) μg/m3 Range (0,0065 – 3,20) mg in the sample cresols - mixture of isomers Range (3,6 – 875) μg/m3 Range (0,0017 – 0,42) mg in the sample xylene – mixture of isomers Range (2,0 – 4000) μg/m3 Range (0,0010 – 8,00) mg in the sample butyl acetate Range (2,0 – 4000) μg/m3 Range (0,0010 – 4,00) mg in the sample ethyl acetate Range (2,0 – 4000) μg/m3 Range (0,0010 – 4,00) mg in the sample vinyl acetate Range (2,0 – 4000) μg/m3 Range (0,0010 – 4,00) mg in the sample styrene Range (2,0 – 4000) μg/m3 Range (0,0010 – 4,00) mg in the sample toluene Range (2,0 – 4000) μg/m3 Range (0,0010 – 4,00) mg in the sample trichloroethene Range (2,0 – 4000) μg/m3 Range (0,0010 – 8,20) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) EV-PB-13 issue 1 of 03.01.2023 EV-PB-14 issue 2 of 28.03.2023
325 Rooms intended for human occupancy: − air − air samples collected into a plastic bag Dinitrogen oxide (nitrous oxide) concentration
Range (3,7 – 3660) mg/m3 Range (2,0 – 1999,2) ppm
Fourier transform infrared spectrometry (FT-IR) EV-PB-18 issue 2 of 13.01.2026

Reference standards (176)

EV-IR-52 issue 1 of 14.10.2019
EV-PB-1 issue 2 of 01.04.2021
EV-PB-10 issue 3 of 17.03.2026
EV-PB-11 issue 2 of 01.04.2021
EV-PB-12 issue 2 of 22.02.2022
EV-PB-13 issue 1 of 03.01.2023 EV-PB-14 issue 2 of 28.03.2023
EV-PB-14 issue 2 of 28.03.2023
EV-PB-17, issue 1 of 18.12.2023
EV-PB-18 issue 2 of 13.01.2026
EV-PB-4 issue 1 of 02.01.2017
EV-PB-4 issue 1 of 02.01.2017
EV-PB-5 issue 3 of 31.03.2025
EV-PB-7 issue 2 of 17.04.2018
EV-PB-8 issue 3 of 18.05.2021
EV-PB-9 issue 2 of 01.04.2021
ISO 12039:2019
ISO 13320:2020
ISO 15713:2006
NIOSH METHOD 1402, Issue 2, 15 August 1994
NIOSH METHOD 1450, Issue 3, 15 March 2003
NIOSH METHOD 2538, Issue 2, dated 15 August 1994
NIOSH Method 1010, Issue 2, 15 August 1994
NIOSH Method 1550, Issue 2, 15 August 1994
NIOSH Method 1550, Issue 2, 15 August 1994
NIOSH NMAM Fourth Edition 8/15/94, Method 1022, Issue 2
OSHA Method PV2009
PN-04009-11:2008
PN-75/Z-04037/03
PN-76/Z-04045/02
PN-76/Z-04045/02 and EV-IR/54 issue 1 of 31.01.2020
PN-78-Z-04112/01
PN-78-Z-04116.01
PN-78-Z-04118-01
PN-78-Z-04119/01
PN-79-Z-04057.01
PN-79/Z-04106.02 EV-IR-68 issue 1 of 18.12.2023 cl. 5.1
PN-81-Z-04134.02
PN-81-Z-04134.03
PN-83-Z-04110/02
PN-83/E-04040.03
PN-83/E-04040.03 EV-PB-2 issue 1 of 02.01.2017
PN-84-Z-04014/02 Principles and Methods of Assessing the Working Environment 2017, No. 1 (95), pp. 73–85
PN-86-Z-04152/02
PN-86-Z-04155/02
PN-87-Z-04178/02
PN-87/B-02156
PN-87/Z-04100.03
PN-89/Z-04023/02
PN-92-Z-04113/09
PN-92-Z-04224/02
PN-EN 12619:2013-05
PN-EN 13211+AC:2006
PN-EN 13284-1:2018-02
PN-EN 13284-1:2018-02 EV-IR-48 issue 2 of 26.03.2026
PN-EN 13649:2005
PN-EN 13649:2005 EV-IR-52 issue 1 of 14.10.2019
PN-EN 14253+A1:2011
PN-EN 14255-1:2010
PN-EN 14255-2:2010
PN-EN 14385:2005
PN-EN 14385:2005 EV-PB-16 issue 3 of 25.03.2024
PN-EN 14789:2017-04
PN-EN 14790:2017-04
PN-EN 14791:2017-04
PN-EN 14792:2017-04
PN-EN 15058:2017-04
PN-EN 1838:2025-05 excluding clauses: 5.1.3-5.1.9, 5.2.3-5.2.7, 5.3.4-5.3.8, 5.4.2, 6, 7, Method A
PN-EN 1911:2011
PN-EN ISO 11079:2008
PN-EN ISO 16911-1:2013-07 CEN/TR 17078:2017
PN-EN ISO 21877:2020-03
PN-EN ISO 5349-1:2004
PN-EN ISO 5349-2:2004
PN-EN ISO 5349-2:2004/A1:2015-11
PN-EN ISO 7243:2018-01
PN-EN ISO 7730:2006 +Ap2:2016-04
PN-EN ISO 9612:2025-11 excluding the methods covering strategies 2 and 3 – cl. 10 and 11
PN-ISO 10396:2001
PN-N-01307:1994
PN-T-05687:2002, cl. 2.5.4
PN-T-06580-3:2002 EV-PB-15 issue 1 of 18.12.2023
PN-Z-01339:2020-12
PN-Z-04007-2:1994
PN-Z-04007-2:1994 excluding cl. 7 EV-IR-53 issue 1 of 14.10.2019
PN-Z-04008-7:2002+Az1:2004
PN-Z-04015-12/Ap1:2001
PN-Z-04015-12:1996
PN-Z-04015-13:1996
PN-Z-04016-10:2005
PN-Z-04016-4:1998
PN-Z-04016-5:1998
PN-Z-04016-6:1998
PN-Z-04022-3:2001
PN-Z-04023-02:1989
PN-Z-04023-02:1998
PN-Z-04029-01:1981
PN-Z-04030-7:1994
PN-Z-04045-06:1982
PN-Z-04045-09:1992
PN-Z-04073-1:2014-08
PN-Z-04102-3:2013-10
PN-Z-04106-02:1979
PN-Z-04106-02:1979 EV-IR-72 issue 1 of 03.01.2025
PN-Z-04108-05:2006
PN-Z-04113-05:1989
PN-Z-04113-06:1986
PN-Z-04113-08:1992
PN-Z-04113-12:2005
PN-Z-04119-01:1978
PN-Z-04119-10:2008
PN-Z-04119-11:2008
PN-Z-04119-7:2006
PN-Z-04126-03:1987
PN-Z-04136-3:2003
PN-Z-04146-3:2006
PN-Z-04148-02:1985
PN-Z-04155-4:1996
PN-Z-04166-02:1986
PN-Z-04167-02:1986 Principles and Methods of Assessing the Working Environment 2010, No. 1 (63), pp. 169–175
PN-Z-04187-02:1988
PN-Z-04196-02:1988
PN-Z-04214-02:1990
PN-Z-04235-3:2001
PN-Z-04244-2:1996
PN-Z-04283:2001
PN-Z-04291:2003
PN-Z-04294:2001
PN-Z-04304:2003
PN-Z-04318:2005
PN-Z-04323:2004
PN-Z-04354:2005
PN-Z-04368:2008
PN-Z-04372:2009
PN-Z-04376:2010
PN-Z-04399:2011
PN-Z-04422:2010
PN-Z-04423:2011
PN-Z-04429:2011
PN-Z-04434:2011
PN-Z-04435:2011
PN-Z-04436:2011
PN-Z-04442:2023-10
PN-Z-04447:2014-06
PN-Z-04449:2014-06
PN-Z-04450:2014-08
PN-Z-04468:2015-10
PN-Z-04469:2025-02
PN-Z-04470:2015-10
PN-Z-04472:2015-10
PN-Z-04472:2015-10/Ap1:2015-12
PN-Z-04476:2016-10
PN-Z-04487:2017-10
PN-Z-04488:2017-10
PN-Z-04502:2019-10 EV-IR-72 issue 1 of 03.01.2025
PN-Z-04507:2022-05
PN-Z-04507:2022-05/Ap1:2022-08
PN-Z-04508:2022-05
PN-Z-04508:2022-05/Ap1:2022-08
PN-Z-71-Z-04041
Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 91–150
Principles and Methods of Assessing the Working Environment 1997, No. 16 pp. 39-42
Principles and Methods of Assessing the Working Environment 1997, No. 17 pp. 55-59
Principles and Methods of Assessing the Working Environment 1998, No. 19 pp. 160-164
Principles and Methods of Assessing the Working Environment 1999 No. 22, pp. 91-95
Principles and Methods of Assessing the Working Environment 1999, No. 22 pp. 91-95
Principles and Methods of Assessing the Working Environment 2004 No. 4(42) pp. 67-73
Principles and Methods of Assessing the Working Environment 2010, No. 1 (63), pp. 185–192
Principles and Methods of Assessing the Working Environment 2011 No. 1 (67), pp. 185-192
Principles and Methods of Assessing the Working Environment 2011, No. 1 (67), pp. 35–44
Principles and Methods of Assessing the Working Environment 2012, No. 4 (74), pp. 117–130
Principles and Methods of Assessing the Working Environment 2015 No. 4(86), pp. 191-202
Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 151–180
Principles and Methods of Assessing the Working Environment 2017, No. 2 (92), pp. 149–160
Principles and Methods of Assessing the Working Environment 2023, No. 3 (117), 95-122
Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 consolidated text Journal of Laws 2023 item 1706 excluding cl. F
based on NIOSH NMAM Fourth Edition 8/15/94 Method 2541, Issue 2 and OSHA Method 52

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/PL/AB%201642