🇵🇱 Laboratorium EMVO Spółka Jawna PL

PCA AB 1630 • Warszawa, Poland • 15 methods

Environment

Laboratorium EMVO Spółka Jawna is a laboratory accredited by PCA under number AB 1630 (Warszawa, Poland). Its accreditation scope covers 15 test methods in the following areas: Environment. Test objects include: Workplace environment – electromagnetic field *), Environment - electromagnetic field in the vicinity of radiocommuni…, Workplace environment - electromagnetic field from transmitting dev…, Workplace environment - electromagnetic field in the workspace from…. Most frequently used techniques: Direct measurement method, (calculated).

At a glance

  • Accreditation number: PCA AB 1630
  • Methods in scope: 15
  • Types of test objects: 5
  • Techniques used: 2
  • City: Warszawa, Poland
Accreditation number
AB 1630
Accreditation body
PCA
Address
Urbański, Pawelak, ul. Jasna 1, 00-013 Warszawa
City
Warszawa, Poland

What this laboratory tests (5)

Analytical techniques used (2)

Laboratory locations

Certificate information

Issue date
29.06.2026
Issue no.
20

Accreditation scope — test methods (15)

No. Test object Methodology / Parameters Technique Reference document
EMVO Spółka Jawna Urbański, Pawelak Laboratory, ul. Mostowa 1, 80-778 Gdańsk
1 Workplace environment - electromagnetic field from transmitting devices of radiocommunication systems Electric field strength:
in the frequency range from 27 MHz to 90 GHz Range (0,8 – 260) V/m
Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (consolidated text: Journal of Laws of 2018, item 331).
Direct measurement method Principles and Methods of Assessing the Working Environment 2017, No. 2 (92), pp. 89–131
2 Workplace environment - electromagnetic field from transmitting devices of radiocommunication systems Magnetic field strength:
in the frequency range from 27 MHz to 1 GHz Range (0,01 – 14) A/m
Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (consolidated text: Journal of Laws of 2018, item 331).
Direct measurement method Principles and Methods of Assessing the Working Environment 2017, No. 2 (92), pp. 89–131
3 Workplace environment - electromagnetic field from transmitting devices of radiocommunication systems Magnetic field strength:
in the frequency range from 800 MHz to 90 GHz
Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (consolidated text: Journal of Laws of 2018, item 331).
(calculated) Principles and Methods of Assessing the Working Environment 2017, No. 2 (92), pp. 89–131
4 Workplace environment - electromagnetic field in the workspace from magnetotherapy devices *) Electric field strength:
in the frequency range from 10 Hz to 400 kHz Range 1 V/m – 41 kV/m
Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (consolidated text: Journal of Laws of 2018, item 331).
Direct measurement method Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 151–180
5 Workplace environment - electromagnetic field in the workspace from magnetotherapy devices *) Magnetic flux density:
in the frequency range from 10 Hz to 400 kHz Range 1 µT – 19 mT
Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (consolidated text: Journal of Laws of 2018, item 331).
Direct measurement method Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 151–180
6 Workplace environment - electromagnetic field in the workspace from magnetotherapy devices *) Magnetic field strength:
in the frequency range from 10 Hz to 400 kHz
Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (consolidated text: Journal of Laws of 2018, item 331).
(calculated) Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 151–180
7 Workplace environment – electromagnetic field *) Electric field strength:
in the frequency range from 10 Hz to 400 kHz Range 1 V/m – 41 kV/m in the frequency range from 400 kHz to 27 MHz Range (0,8 – 1000) V/m in the frequency range from 27 MHz to 90 GHz Range (0,8 – 260) V/m
Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (consolidated text: Journal of Laws of 2018, item 331).
Direct measurement method PN-T-06580-3:2002 Method adapted to the regulated area
8 Workplace environment – electromagnetic field *) Magnetic flux density:
in the frequency range from 10 Hz to 400 kHz Range 1 µT – 19 mT
Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (consolidated text: Journal of Laws of 2018, item 331).
Direct measurement method PN-T-06580-3:2002 Method adapted to the regulated area
9 Workplace environment – electromagnetic field *) Magnetic field strength:
in the frequency range from 400 kHz to 27 MHz Range (0,012 – 16) A/m in the frequency range from 27 MHz to 1 GHz Range (0,01 – 14) A/m
Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (consolidated text: Journal of Laws of 2018, item 331).
Direct measurement method PN-T-06580-3:2002 Method adapted to the regulated area
10 Workplace environment – electromagnetic field *) Magnetic field strength:
in the frequency range from 5 Hz to 400 kHz in the frequency range from 800 MHz to 90 GHz
Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (consolidated text: Journal of Laws of 2018, item 331).
(calculated) PN-T-06580-3:2002 Method adapted to the regulated area
11 Environment - electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) Electric field strength:
in the frequency range from 10 MHz to 90 GHz Range (0,8 – 260) V/m
Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Direct measurement method Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630)
12 Environment - electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) Magnetic field strength:
in the frequency range: from 27 MHz to 1GHz Range (0,01 – 14) A/m
Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Direct measurement method Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630)
13 Environment - electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) Magnetic field strength:
in the frequency range: from 10 MHz to 90 GHz
Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
(calculated) Cl. 3 Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630)
14 Environment - electromagnetic field in the vicinity of radiocommunication installations (selective measurements) Electric field strength:
in the frequency range: from 420 MHz to 6 GHz Range (0,1 – 200) V/m
Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Direct measurement method Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630)
15 Environment - electromagnetic field in the vicinity of radiocommunication installations (selective measurements) Magnetic field strength:
in the frequency range from 420 MHz to 6 GHz
Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
(calculated) Cl. 3 Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630)

Reference standards (5)

PN-T-06580-3:2002 Method adapted to the regulated area
Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 151–180
Principles and Methods of Assessing the Working Environment 2017, No. 2 (92), pp. 89–131
Cl. 3 Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630)
Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630)

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/PL/AB%201630