🇵🇱 Laboratorium EMVO Spółka Jawna PL
Environment
Laboratorium EMVO Spółka Jawna is a laboratory accredited by PCA under number AB 1630 (Warszawa, Poland). Its accreditation scope covers 15 test methods in the following areas: Environment. Test objects include: Workplace environment – electromagnetic field *), Environment - electromagnetic field in the vicinity of radiocommuni…, Workplace environment - electromagnetic field from transmitting dev…, Workplace environment - electromagnetic field in the workspace from…. Most frequently used techniques: Direct measurement method, (calculated).
At a glance
- Accreditation number: PCA AB 1630
- Methods in scope: 15
- Types of test objects: 5
- Techniques used: 2
- City: Warszawa, Poland
- Accreditation number
- AB 1630
- Accreditation body
- PCA
- Address
- Urbański, Pawelak, ul. Jasna 1, 00-013 Warszawa
- City
- Warszawa, Poland
What this laboratory tests (5)
- Workplace environment – electromagnetic field *) — 4 methods
- Environment - electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) — 3 methods
- Workplace environment - electromagnetic field from transmitting devices of radiocommunication systems — 3 methods
- Workplace environment - electromagnetic field in the workspace from magnetotherapy devices *) — 3 methods
- Environment - electromagnetic field in the vicinity of radiocommunication installations (selective measurements) — 2 methods
Analytical techniques used (2)
- Direct measurement method — 10 methods
- (calculated) — 5 methods
Laboratory locations
- Laboratorium EMVO Spółka Jawna (main site) — ul. Jasna 1, 00-013 Warszawa
- EMVO Spółka Jawna Urbański, Pawelak Laboratory — ul. Jasna 1, 00-013 Warszawa
- EMVO Spółka Jawna Urbański, Pawelak Laboratory — ul. Mostowa 1, 80-778 Gdańsk
Certificate information
- Issue date
- 29.06.2026
- Issue no.
- 20
Accreditation scope — test methods (15)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| EMVO Spółka Jawna Urbański, Pawelak Laboratory, ul. Mostowa 1, 80-778 Gdańsk | |||||
| 1 | Workplace environment - electromagnetic field from transmitting devices of radiocommunication systems | Electric field strength: in the frequency range from 27 MHz to 90 GHz Range (0,8 – 260) V/m Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the legally regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (consolidated text: Journal of Laws of 2018, item 331). |
Direct measurement method | Principles and Methods of Assessing the Working Environment 2017, No. 2 (92), pp. 89–131 | |
| 2 | Workplace environment - electromagnetic field from transmitting devices of radiocommunication systems | Magnetic field strength: in the frequency range from 27 MHz to 1 GHz Range (0,01 – 14) A/m Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the legally regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (consolidated text: Journal of Laws of 2018, item 331). |
Direct measurement method | Principles and Methods of Assessing the Working Environment 2017, No. 2 (92), pp. 89–131 | |
| 3 | Workplace environment - electromagnetic field from transmitting devices of radiocommunication systems | Magnetic field strength: in the frequency range from 800 MHz to 90 GHz Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the legally regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (consolidated text: Journal of Laws of 2018, item 331). |
(calculated) | Principles and Methods of Assessing the Working Environment 2017, No. 2 (92), pp. 89–131 | |
| 4 | Workplace environment - electromagnetic field in the workspace from magnetotherapy devices *) | Electric field strength: in the frequency range from 10 Hz to 400 kHz Range 1 V/m – 41 kV/m Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the legally regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (consolidated text: Journal of Laws of 2018, item 331). |
Direct measurement method | Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 151–180 | |
| 5 | Workplace environment - electromagnetic field in the workspace from magnetotherapy devices *) | Magnetic flux density: in the frequency range from 10 Hz to 400 kHz Range 1 µT – 19 mT Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the legally regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (consolidated text: Journal of Laws of 2018, item 331). |
Direct measurement method | Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 151–180 | |
| 6 | Workplace environment - electromagnetic field in the workspace from magnetotherapy devices *) | Magnetic field strength: in the frequency range from 10 Hz to 400 kHz Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the legally regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (consolidated text: Journal of Laws of 2018, item 331). |
(calculated) | Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 151–180 | |
| 7 | Workplace environment – electromagnetic field *) | Electric field strength: in the frequency range from 10 Hz to 400 kHz Range 1 V/m – 41 kV/m in the frequency range from 400 kHz to 27 MHz Range (0,8 – 1000) V/m in the frequency range from 27 MHz to 90 GHz Range (0,8 – 260) V/m Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the legally regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (consolidated text: Journal of Laws of 2018, item 331). |
Direct measurement method | PN-T-06580-3:2002 Method adapted to the regulated area | |
| 8 | Workplace environment – electromagnetic field *) | Magnetic flux density: in the frequency range from 10 Hz to 400 kHz Range 1 µT – 19 mT Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the legally regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (consolidated text: Journal of Laws of 2018, item 331). |
Direct measurement method | PN-T-06580-3:2002 Method adapted to the regulated area | |
| 9 | Workplace environment – electromagnetic field *) | Magnetic field strength: in the frequency range from 400 kHz to 27 MHz Range (0,012 – 16) A/m in the frequency range from 27 MHz to 1 GHz Range (0,01 – 14) A/m Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the legally regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (consolidated text: Journal of Laws of 2018, item 331). |
Direct measurement method | PN-T-06580-3:2002 Method adapted to the regulated area | |
| 10 | Workplace environment – electromagnetic field *) | Magnetic field strength: in the frequency range from 5 Hz to 400 kHz in the frequency range from 800 MHz to 90 GHz Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the legally regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (consolidated text: Journal of Laws of 2018, item 331). |
(calculated) | PN-T-06580-3:2002 Method adapted to the regulated area | |
| 11 | Environment - electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) | Electric field strength: in the frequency range from 10 MHz to 90 GHz Range (0,8 – 260) V/m Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the legally regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Direct measurement method | Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630) | |
| 12 | Environment - electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) | Magnetic field strength: in the frequency range: from 27 MHz to 1GHz Range (0,01 – 14) A/m Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the legally regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Direct measurement method | Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630) | |
| 13 | Environment - electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) | Magnetic field strength: in the frequency range: from 10 MHz to 90 GHz Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the legally regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
(calculated) | Cl. 3 Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630) | |
| 14 | Environment - electromagnetic field in the vicinity of radiocommunication installations (selective measurements) | Electric field strength: in the frequency range: from 420 MHz to 6 GHz Range (0,1 – 200) V/m Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the legally regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Direct measurement method | Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630) | |
| 15 | Environment - electromagnetic field in the vicinity of radiocommunication installations (selective measurements) | Magnetic field strength: in the frequency range from 420 MHz to 6 GHz Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the legally regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
(calculated) | Cl. 3 Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630) | |
Reference standards (5)
PN-T-06580-3:2002 Method adapted to the regulated area
Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 151–180
Principles and Methods of Assessing the Working Environment 2017, No. 2 (92), pp. 89–131
Cl. 3 Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630)
Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630)