🇵🇱 Przedsiębiorstwo Badań i Analiz Energetycznych PL
Environment
Przedsiębiorstwo Badań i Analiz Energetycznych is a laboratory accredited by PCA under number AB 1624 (Przeźmierowo, Poland). Its accreditation scope covers 100 test methods in the following areas: Environment. Test objects include: Waste gases, Automated Measuring Systems (AMS), Workplace environment - noise, Machinery and equipment including cooling towers, chimneys, turbine…. Most frequently used techniques: Non-dispersive infrared spectrometry (NDIR), Direct measurement method, Fourier transform infrared spectroscopy (FTIR).
At a glance
- Accreditation number: PCA AB 1624
- Methods in scope: 100
- Types of test objects: 5
- Techniques used: 18
- City: Przeźmierowo, Poland
- Accreditation number
- AB 1624
- Accreditation body
- PCA
- Address
- ENERGOTHERM Sp. z o.o., LABORATORIUM BADAWCZE, ul. Poznańska 5, 62 – 081 Przeźmierowo
- City
- Przeźmierowo, Poland
What this laboratory tests (5)
- Waste gases — 67 methods
- Automated Measuring Systems (AMS) — 24 methods
- Workplace environment - noise — 4 methods
- Machinery and equipment including cooling towers, chimneys, turbines and turbine sets – noise — 3 methods
- General environment - noise from installations, equipment and industrial plants — 2 methods
Analytical techniques used (18)
- Non-dispersive infrared spectrometry (NDIR) — 10 methods
- Direct measurement method — 6 methods
- Fourier transform infrared spectroscopy (FTIR) — 4 methods
- Gravimetric method — 4 methods
- Paramagnetic method — 3 methods
- Thoron method — 3 methods
- Chemiluminescence method — 2 methods
- Condensation- adsorption method; Temperature method — 2 methods
- Continuous flame ionization detection method (FID) — 2 methods
- Filtration-condensation method — 2 methods
- Zirconia cell method — 2 methods
- Aspiration method using an absorbing solution — 1 method
- Calculation method — 1 method
- Chemiluminescence method CLD — 1 method
- Differential pressure measurement method — 1 method
- and 3 more
Laboratory locations
- Przedsiębiorstwo Badań i Analiz Energetycznych (main site) — ul. Poznańska 5, 62-081 Przeźmierowo
- TESTING LABORATORY — ul. Poznańska 5
Certificate information
- Issue date
- 24.07.2026
- Issue no.
- 16
Accreditation scope — test methods (100)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Testing Laboratory | |||||
| 1 | Waste gases | Gas velocity and volume flow rate for differential pressures > 5 Pa Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Differential pressure measurement method | PN-EN ISO 16911-1:2013-07 | |
| 2 | Waste gases | Gas volume flow rate for dynamic pressures > 10 Pa Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Stagnation pressure method | PN-Z-04030-7:1994 | |
| 3 | Waste gases | Sampling for determination of dust concentration Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
PN-Z-04030-7:1994 | ||
| 4 | Waste gases | Dust concentration Range (0,001 – 100) g/m3 Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Gravimetric method | PN-Z-04030-7:1994 | |
| 5 | Waste gases | Dust emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
PN-Z-04030-7:1994 | ||
| 6 | Waste gases | Sampling for determination of dust concentration Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
PN-EN 13284-1:2018-02 | ||
| 7 | Waste gases | Dust concentration Range (0,48 – 50) mg/m3 Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Gravimetric method | PN-EN 13284-1:2018-02 | |
| 8 | Waste gases | Dust emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
PN-EN 13284-1:2018-02 | ||
| 9 | Waste gases | Sulphur dioxide concentration SO2 (8,0 – 5100) mg/m3 Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Non-dispersive infrared spectrometry (NDIR) | ISO 10396:2007 | PN-ISO 7935:2000 | |
| 10 | Waste gases | SO2 emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
ISO 10396:2007 | PN-ISO 7935:2000 | ||
| 11 | Waste gases | Concentration of nitrogen monoxide, nitrogen dioxide, nitrogen oxides NO (2,3 – 620) mg/m3 NO2 (3,6 – 950) mg/m3 NOx (3,6 – 950) mg/m3 Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Chemiluminescence method | PN-EN 14792:2017 | ISO 10396:2007 | |
| 12 | Waste gases | Emission of NO and NO2, NOx (NO and NO2 expressed as NO2) (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
PN-EN 14792:2017 | ISO 10396:2007 | ||
| 13 | Waste gases | Carbon dioxide concentration CO2 (0,6 – 18) % Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Non-dispersive infrared spectrometry (NDIR) | ISO 12039:2019 | ISO 10396:2007 | |
| 14 | Waste gases | Carbon dioxide emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
ISO 12039:2019 | ISO 10396:2007 | ||
| 15 | Waste gases | Carbon monoxide concentration CO (3,0 – 1200) mg/m3 Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Non-dispersive infrared spectrometry (NDIR) | PN-EN 15058:2017 | ISO 10396:2007 | |
| 16 | Waste gases | Carbon monoxide emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
PN-EN 15058:2017 | ISO 10396:2007 | ||
| 17 | Waste gases | Oxygen concentration O2 (0,7 – 21,0) % Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Paramagnetic method | PN-EN 14789:2017 | ISO 10396:2007 | |
| 18 | Waste gases | Concentration of nitrogen oxide, nitrogen dioxide, sulphur dioxide, carbon dioxide NO (5,9 – 1050) mg/m3 NO2 (4,4 – 100) mg/m3 SO2 (13,2 – 5100) mg/m3 CO2 (1,0 – 22,0) % CO (2,1 – 1800) mg/m3 Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Fourier transform infrared spectroscopy (FTIR) | ISO 10396:2007 | Test instruction ILB/5.4/.4 version 4 of 09.06.2018 | |
| 19 | Waste gases | Oxygen concentration Range (0,9 – 21,0) % Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Zirconia cell method | ISO 10396:2007 | Test instruction ILB/5.4/.4 version 4 of 09.06.2018 | |
| 20 | Waste gases | Emission of NO, NO2, SO2, CO2, CO (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
ISO 10396:2007 | Test instruction ILB/5.4/.4 version 4 of 09.06.2018 | ||
| 21 | Waste gases | Water vapour concentration (H2O) Range (4,0 − 40) % vol. Range (3,14 – 57,41) % Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Condensation- adsorption method; Temperature method | PN-EN 14790:2017-04 | |
| 22 | Waste gases | Sampling for determination of SO2 concentration Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
PN-EN 14791:2017-04 | ||
| 23 | Waste gases | SO2 concentration Range (5 – 2000) mg/m3 Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Thoron method | PN-EN 14791:2017-04 | |
| 24 | Waste gases | SO2 emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
PN-EN 14791:2017-04 | ||
| 25 | Waste gases | Sampling for determination of hydrogen chloride concentration Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
PN-EN 1911:2011 | ||
| 26 | Waste gases | Hydrogen chloride emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
PN-EN 1911:2011 | ||
| 27 | Waste gases | Sampling for determination of hydrogen fluoride concentration Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
ISO 15713:2006 | ||
| 28 | Waste gases | Hydrogen fluoride emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
ISO 15713:2006 | ||
| 29 | Waste gases | Sampling for determination of total mercury concentration Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
PN-EN 13211:2006 | ||
| 30 | Waste gases | Total mercury emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
PN-EN 13211:2006 | ||
| 31 | Waste gases | Sampling for determination of metal concentrations: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
PN-EN 14385:2025-05 | ||
| 32 | Waste gases | Emission of As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
PN-EN 14385:2025-05 | ||
| 33 | Waste gases | Concentration of organic substances in the form of gases and vapours expressed as total gaseous organic carbon Range (1,9 – 290,0) mg/m3 Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Continuous flame ionization detection method (FID) | PN-EN 12619:2013-05 | |
| 34 | Waste gases | Emission of organic substances in gaseous and vapour form expressed as total gaseous organic carbon (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
PN-EN 12619:2013-05 | ||
| 35 | Waste gases | Sampling for the determination of PCDD/PCDF concentration Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Filtration-condensation method | PN-EN 1948-1:2006 | PN-EN 1948-4+A1:2014-03 | |
| 36 | Waste gases | PCDD/PCDF emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
PN-EN 1948-1:2006 | PN-EN 1948-4+A1:2014-03 | ||
| 37 | Waste gases | Sampling for determination of the concentration of individual gaseous organic compounds Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Method using activated carbon | PN-EN 13649:2005 | |
| 38 | Waste gases | Emission of individual gaseous organic compounds (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
PN-EN 13649:2005 | ||
| 39 | Waste gases | Sampling for determination of the dust fraction | PN-Z-04030-7:1994 | Test instruction ILB/5.6/1 version 2 of 15.06.2016 | ||
| 40 | Waste gases | Emission of the dust fraction (calculated) | PN-Z-04030-7:1994 | Test instruction ILB/5.6/1 version 2 of 15.06.2016 | ||
| 41 | Waste gases | Ammonia (NH3) concentration Range (1,1 – 36) mg/m3 |
Fourier transform infrared spectroscopy (FTIR) | ISO 10396:2007 | Test instruction ILB/5.4/.4 version 4 of 09.06.2018 | |
| 42 | Waste gases | Ammonia (NH3) emission (calculated) | ISO 10396:2007 | Test instruction ILB/5.4/.4 version 4 of 09.06.2018 | ||
| 43 | Waste gases | Sampling for the determination of ammonia (NH3) concentration | PN-EN ISO 21877:2020-03 | ||
| 44 | Waste gases | Ammonia (NH3) emission (calculated) | PN-EN ISO 21877:2020-03 | ||
| 45 | Waste gases | Sampling for the determination of SO3, H2SO4 concentration | VDI 2462-2:2011 | ||
| 46 | Waste gases | Concentration of SO3, H2SO4 SO3 (5,0 – 50) mg/m3 H2SO4 (3,6 – 50) mg/m3 |
Thoron method | VDI 2462-2:2011 | |
| 47 | Waste gases | Emission of SO3, H2SO4 (calculated) | VDI 2462-2:2011 | ||
| 48 | Waste gases | SO2 concentration Range (8,0 – 2400) mg/m3 |
Non-dispersive infrared spectrometry (NDIR) | PN-ISO 10396:2001 | Test instruction ILB/5.4/5 version 2 of 29.05.2018 | |
| 49 | Waste gases | NO, NOx concentration NO (2,3 – 620) mg/m3 NOx (3,6 – 950) mg/m3 |
Chemiluminescence method CLD | PN-EN 14792:2017 | PN-ISO 10396:2001 | Test instruction ILB/5.4/5 version 2 of 29.05.2018 | |
| 50 | Waste gases | CO concentration Range (3,0 – 1200) mg/m3 |
Non-dispersive infrared spectrometry (NDIR) | PN-EN 15058:2017 | PN-ISO 10396:2001 | Test instruction ILB/5.4/5 version 2 of 29.05.2018 | |
| 51 | Waste gases | O2 concentration Range (0,7 – 21,0) % |
Paramagnetic method | PN-EN 14789:2017 | PN-ISO 10396:2001 | Test instruction ILB/5.4/5 version 2 of 29.05.2018 | |
| 52 | Waste gases | CO2 concentration Range (0,6 – 18) % |
Non-dispersive infrared spectrometry (NDIR) | PN-ISO 10396:2001 | Test instruction ILB/5.4/5 version 2 of 29.05.2018 | |
| 53 | Waste gases | Concentration of nitrogen oxide, nitrogen dioxide, sulphur dioxide, carbon dioxide NO (5,9 – 1050) mg/m3 NO2 (4,4 – 100) mg/m3 SO2 (13,2 – 5100) mg/m3 NH3 (1,1 – 36) mg/m3 CO2 (1,0 – 22,0) % CO (2,1 – 1800) mg/m3 |
Fourier transform infrared spectroscopy (FTIR) | PN-ISO 10396:2001 | Test instruction ILB/5.4/.4 version 4 of 09.06.2018 | |
| 54 | Waste gases | Oxygen concentration Range (0,9 – 21,0) % |
Zirconia cell method | PN-ISO 10396:2001 | Test instruction ILB/5.4/.4 version 4 of 09.06.2018 | |
| 55 | Waste gases | Emission of NO, NO2, SO2, NH3, CO2, CO (calculated) | PN-ISO 10396:2001 | Test instruction ILB/5.4/.4 version 4 of 09.06.2018 | ||
| 56 | Waste gases | Sampling for determination of metal concentrations: Se, Zn | PN-EN 14385:2025-05 | ||
| 57 | Waste gases | Emission of metals: Se, Zn (calculated) | PN-EN 14385:2025-05 | ||
| 58 | Waste gases | Sampling for the determination of the concentration of dioxin-like PCBs | Filtration-condensation method | PN-EN 1948-4+A1:2014-03 | |
| 59 | Waste gases | Emission of dioxin-like PCB (calculated) | PN-EN 1948-4+A1:2014-03 | ||
| 60 | Waste gases | Sampling for the determination of the mass concentration of PAHs | Filtration-condensation-absorption method | ISO 11338-1:2003 | |
| 61 | Waste gases | PAH emission (calculated) | ISO 11338-1:2003 | ||
| 62 | Waste gases | N2O concentration Range (1,4 – 285,0) mg/m3 |
Non-dispersive infrared spectrometry (NDIR) | PN-EN ISO 21258:2010 | |
| 63 | Waste gases | N2O emission (calculated) | PN-EN ISO 21258:2010 | ||
| 64 | Waste gases | Sampling for determination of hydrogen fluoride concentration | CEN/TS 17340:2020-09 | ||
| 65 | Waste gases | Hydrogen fluoride emission (calculated) | CEN/TS 17340:2020-09 | ||
| 66 | Waste gases | Sampling for determination of hydrogen sulfide concentration (H2S) | Aspiration method using an absorbing solution | VDI 3486 Blatt 2:1979 | |
| 67 | Waste gases | Hydrogen sulfide (H2S) emission (calculated) | VDI 3486 Blatt 2:1979 | ||
| 68 | Automated Measuring Systems (AMS) | AMS calibration (QAL2) for: dust, SO2, NO, NO2, NOx, CO, O2, CO2, H2O, organic substances in the form of gases and vapours expressed as total gaseous organic carbon, HCl, HF, Hg Regulated area: Continuous measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
PN-EN 14181:2015 | ||
| 69 | Automated Measuring Systems (AMS) | Annual surveillance test (AST) for: dust, SO2, NO, NO2, NOx, CO, O2, CO2, H2O, organic substances in the form of gases and vapours expressed as total gaseous organic carbon, HCl, HF, Hg Regulated area: Continuous measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
PN-EN 14181:2015 | ||
| 70 | Automated Measuring Systems (AMS) | Dust concentration Range (0,001 – 100) g/m3 Regulated area: Continuous measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Gravimetric method | PN-Z-04030-7:1994 | |
| 71 | Automated Measuring Systems (AMS) | Dust concentration Range (0,48 – 50) mg/m3 Regulated area: Continuous measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Gravimetric method | PN-EN 13284-1:2018-02 | |
| 72 | Automated Measuring Systems (AMS) | SO2 concentration Range (5 – 2000) mg/m3 Regulated area: Continuous measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Thoron method | PN-EN 14791:2017-04 | |
| 73 | Automated Measuring Systems (AMS) | NO, NO2, NOx concentration NO (2,3 – 620) mg/m3 NO2 (3,6 – 950) mg/m3 NOx (3,6 – 950) mg/m3 Regulated area: Continuous measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Chemiluminescence method | PN-EN 14792:2017 | |
| 74 | Automated Measuring Systems (AMS) | CO concentration Range (3,0 - 1200) mg/m3 Regulated area: Continuous measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Non-dispersive infrared spectrometry (NDIR) | PN-EN 15058:2017 | |
| 75 | Automated Measuring Systems (AMS) | O2 concentration Range (0,7 – 21) % Regulated area: Continuous measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Paramagnetic method | PN-EN 14789:2017 | |
| 76 | Automated Measuring Systems (AMS) | Water vapour concentration (H2O) Range (4,0 − 40) % vol. Range (3,14 – 57,41) % Regulated area: Continuous measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Condensation- adsorption method; Temperature method | PN-EN 14790:2017-04 | |
| 77 | Automated Measuring Systems (AMS) | Concentration of organic substances in the form of gases and vapours expressed as total gaseous organic carbon Range (1,9 – 290,0) mg/m3 Regulated area: Continuous measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Continuous flame ionization detection method (FID) | PN-EN 12619:2013-05 | |
| 78 | Automated Measuring Systems (AMS) | Calibration of AMS (QAL2) for: NH3, N2O | PN-EN 14181:2015 | ||
| 79 | Automated Measuring Systems (AMS) | Annual surveillance test (AST) for: NH3, N2O | PN-EN 14181:2015 | ||
| 80 | Automated Measuring Systems (AMS) | NH3 concentration Range (1,1 – 36) mg/m3 |
Fourier transform infrared spectroscopy (FTIR) | ISO 10396:2007 | Test instruction ILB/5.4/.4 version 4 of 09.06.2018 | |
| 81 | Automated Measuring Systems (AMS) | N2O concentration Range (1,4 – 285,0) mg/m3 |
Non-dispersive infrared spectrometry (NDIR) | PN-EN ISO 21258:2010 | |
| 82 | Automated Measuring Systems (AMS) | N2O emission (calculated) | PN-EN ISO 21258:2010 | ||
| 83 | Automated Measuring Systems (AMS) | Sampling for determination of hydrogen chloride concentration | PN-EN 1911:2011 | ||
| 84 | Automated Measuring Systems (AMS) | Hydrogen chloride emission (calculated) | PN-EN 1911:2011 | ||
| 85 | Automated Measuring Systems (AMS) | Sampling for determination of hydrogen fluoride concentration | ISO 15713:2006 | CEN/TS 17340:2020-09 | ||
| 86 | Automated Measuring Systems (AMS) | Hydrogen fluoride emission (calculated) | ISO 15713:2006 | CEN/TS 17340:2020-09 | ||
| 87 | Automated Measuring Systems (AMS) | Sampling for determination of total mercury concentration | PN-EN 13211:2006 | ||
| 88 | Automated Measuring Systems (AMS) | Total mercury emission (calculated) | PN-EN 13211:2006 | ||
| 89 | Automated Measuring Systems (AMS) | Sampling for determination of ammonia concentration | PN-EN ISO 21877:2020-03 | ||
| 90 | Automated Measuring Systems (AMS) | Ammonia emission (calculated) | PN-EN ISO 21877:2020-03 | ||
| 91 | Automated Measuring Systems (AMS) | CO2 concentration Range (0,6 – 18) % |
Non-dispersive infrared spectrometry (NDIR) | ISO 10396:2007 | ISO 12039:2019 | |
| 92 | Machinery and equipment including cooling towers, chimneys, turbines and turbine sets – noise | A-frequency-weighted sound pressure level Range (26,0 – 136,0) dB |
Direct measurement method | PN-EN ISO 3746:2011 | PN-EN ISO 3746:2011+Ap1:2017-09 excluding cl. 8.4 | PN-EN ISO 3744:2011 excluding cl. 8.3 | DIN 45635-46:1985-06 | DIN 45635-47:1985-06 | ISO 10494:2018 | |
| 93 | Machinery and equipment including cooling towers, chimneys, turbines and turbine sets – noise | Sound pressure level in 1/1 and 1/3 octave bands in the range of centre frequencies Range (20 – 20 000) Hz |
Direct measurement method | PN-EN ISO 3746:2011 | PN-EN ISO 3746:2011+Ap1:2017-09 excluding cl. 8.4 | PN-EN ISO 3744:2011 excluding cl. 8.3 | DIN 45635-46:1985-06 | DIN 45635-47:1985-06 | ISO 10494:2018 | |
| 94 | Machinery and equipment including cooling towers, chimneys, turbines and turbine sets – noise | Sound power level (calculated) | PN-EN ISO 3746:2011 | PN-EN ISO 3746:2011+Ap1:2017-09 excluding cl. 8.4 | PN-EN ISO 3744:2011 excluding cl. 8.3 | DIN 45635-46:1985-06 | DIN 45635-47:1985-06 | ISO 10494:2018 | ||
| 95 | General environment - noise from installations, equipment and industrial plants | A-weighted equivalent sound pressure level Range (26,0 – 136,0) dB |
Direct measurement method | Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (Journal of Laws of 2023 item 1706) | |
| 96 | General environment - noise from installations, equipment and industrial plants | A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) | Calculation method | Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (Journal of Laws of 2023 item 1706) | PN ISO 9613-2:2002 | |
| 97 | Workplace environment - noise | A-weighted equivalent sound pressure level Range (26,0 – 136,0) dB |
Direct measurement method | PN-N-01307: 1994 | PN-EN ISO 9612:2025-11 excluding the method covering strategies 2 and 3 – cl. 10 and 11 | |
| 98 | Workplace environment - noise | Maximum A-weighted sound pressure level Range (26,0 – 136,0) dB |
Direct measurement method | PN-N-01307: 1994 | PN-EN ISO 9612:2025-11 excluding the method covering strategies 2 and 3 – cl. 10 and 11 | |
| 99 | Workplace environment - noise | C-weighted peak sound pressure level Range (40,0 – 138,0) dB |
Direct measurement method | PN-N-01307: 1994 | PN-EN ISO 9612:2025-11 excluding the method covering strategies 2 and 3 – cl. 10 and 11 | |
| 100 | Workplace environment - noise | Noise exposure level referred to: - an 8-hour daily working time, - an average weekly working time (calculated) | PN-N-01307: 1994 | PN-EN ISO 9612:2025-11 excluding the method covering strategies 2 and 3 – cl. 10 and 11 | ||
Reference standards (40)
CEN/TS 17340:2020-09
DIN 45635-46:1985-06
DIN 45635-47:1985-06
ISO 10396:2007
ISO 10494:2018
ISO 11338-1:2003
ISO 12039:2019
ISO 15713:2006
Test instruction ILB/5.4/.4 version 4 of 09.06.2018
Test instruction ILB/5.4/5 version 2 of 29.05.2018
Test instruction ILB/5.6/1 version 2 of 15.06.2016
PN ISO 9613-2:2002
PN-EN 12619:2013-05
PN-EN 13211:2006
PN-EN 13284-1:2018-02
PN-EN 13649:2005
PN-EN 14181:2015
PN-EN 14385:2025-05
PN-EN 14789:2017
PN-EN 14790:2017-04
PN-EN 14791:2017-04
PN-EN 14792:2017
PN-EN 15058:2017
PN-EN 1911:2011
PN-EN 1948-1:2006
PN-EN 1948-4+A1:2014-03
PN-EN ISO 16911-1:2013-07
PN-EN ISO 21258:2010
PN-EN ISO 21877:2020-03
PN-EN ISO 3744:2011 excluding cl. 8.3
PN-EN ISO 3746:2011
PN-EN ISO 3746:2011+Ap1:2017-09 excluding cl. 8.4
PN-EN ISO 9612:2025-11 excluding the method covering strategies 2 and 3 – cl. 10 and 11
PN-ISO 10396:2001
PN-ISO 7935:2000
PN-N-01307: 1994
PN-Z-04030-7:1994
VDI 2462-2:2011
VDI 3486 Blatt 2:1979
Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (Journal of Laws of 2023 item 1706)