🇵🇱 Przedsiębiorstwo Badań i Analiz Energetycznych PL

PCA AB 1624 • Przeźmierowo, Poland • 100 methods

Environment

Przedsiębiorstwo Badań i Analiz Energetycznych is a laboratory accredited by PCA under number AB 1624 (Przeźmierowo, Poland). Its accreditation scope covers 100 test methods in the following areas: Environment. Test objects include: Waste gases, Automated Measuring Systems (AMS), Workplace environment - noise, Machinery and equipment including cooling towers, chimneys, turbine…. Most frequently used techniques: Non-dispersive infrared spectrometry (NDIR), Direct measurement method, Fourier transform infrared spectroscopy (FTIR).

At a glance

  • Accreditation number: PCA AB 1624
  • Methods in scope: 100
  • Types of test objects: 5
  • Techniques used: 18
  • City: Przeźmierowo, Poland
Accreditation number
AB 1624
Accreditation body
PCA
Address
ENERGOTHERM Sp. z o.o., LABORATORIUM BADAWCZE, ul. Poznańska 5, 62 – 081 Przeźmierowo
City
Przeźmierowo, Poland

What this laboratory tests (5)

Analytical techniques used (18)

Laboratory locations

Certificate information

Issue date
24.07.2026
Issue no.
16

Accreditation scope — test methods (100)

No. Test object Methodology / Parameters Technique Reference document
Testing Laboratory
1 Waste gases Gas velocity and volume flow rate for differential pressures > 5 Pa
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Differential pressure measurement method PN-EN ISO 16911-1:2013-07
2 Waste gases Gas volume flow rate for dynamic pressures > 10 Pa
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Stagnation pressure method PN-Z-04030-7:1994
3 Waste gases Sampling for determination of dust concentration
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
PN-Z-04030-7:1994
4 Waste gases Dust concentration
Range (0,001 – 100) g/m3
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Gravimetric method PN-Z-04030-7:1994
5 Waste gases Dust emission (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
PN-Z-04030-7:1994
6 Waste gases Sampling for determination of dust concentration
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
PN-EN 13284-1:2018-02
7 Waste gases Dust concentration
Range (0,48 – 50) mg/m3
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Gravimetric method PN-EN 13284-1:2018-02
8 Waste gases Dust emission (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
PN-EN 13284-1:2018-02
9 Waste gases Sulphur dioxide concentration
SO2 (8,0 – 5100) mg/m3
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Non-dispersive infrared spectrometry (NDIR) ISO 10396:2007 | PN-ISO 7935:2000
10 Waste gases SO2 emission (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
ISO 10396:2007 | PN-ISO 7935:2000
11 Waste gases Concentration of nitrogen monoxide, nitrogen dioxide, nitrogen oxides
NO (2,3 – 620) mg/m3 NO2 (3,6 – 950) mg/m3 NOx (3,6 – 950) mg/m3
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Chemiluminescence method PN-EN 14792:2017 | ISO 10396:2007
12 Waste gases Emission of NO and NO2, NOx (NO and NO2 expressed as NO2) (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
PN-EN 14792:2017 | ISO 10396:2007
13 Waste gases Carbon dioxide concentration
CO2 (0,6 – 18) %
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Non-dispersive infrared spectrometry (NDIR) ISO 12039:2019 | ISO 10396:2007
14 Waste gases Carbon dioxide emission (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
ISO 12039:2019 | ISO 10396:2007
15 Waste gases Carbon monoxide concentration
CO (3,0 – 1200) mg/m3
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Non-dispersive infrared spectrometry (NDIR) PN-EN 15058:2017 | ISO 10396:2007
16 Waste gases Carbon monoxide emission (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
PN-EN 15058:2017 | ISO 10396:2007
17 Waste gases Oxygen concentration
O2 (0,7 – 21,0) %
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Paramagnetic method PN-EN 14789:2017 | ISO 10396:2007
18 Waste gases Concentration of nitrogen oxide, nitrogen dioxide, sulphur dioxide, carbon dioxide
NO (5,9 – 1050) mg/m3 NO2 (4,4 – 100) mg/m3 SO2 (13,2 – 5100) mg/m3 CO2 (1,0 – 22,0) % CO (2,1 – 1800) mg/m3
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Fourier transform infrared spectroscopy (FTIR) ISO 10396:2007 | Test instruction ILB/5.4/.4 version 4 of 09.06.2018
19 Waste gases Oxygen concentration
Range (0,9 – 21,0) %
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Zirconia cell method ISO 10396:2007 | Test instruction ILB/5.4/.4 version 4 of 09.06.2018
20 Waste gases Emission of NO, NO2, SO2, CO2, CO (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
ISO 10396:2007 | Test instruction ILB/5.4/.4 version 4 of 09.06.2018
21 Waste gases Water vapour concentration (H2O)
Range (4,0 − 40) % vol. Range (3,14 – 57,41) %
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Condensation- adsorption method; Temperature method PN-EN 14790:2017-04
22 Waste gases Sampling for determination of SO2 concentration
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
PN-EN 14791:2017-04
23 Waste gases SO2 concentration
Range (5 – 2000) mg/m3
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Thoron method PN-EN 14791:2017-04
24 Waste gases SO2 emission (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
PN-EN 14791:2017-04
25 Waste gases Sampling for determination of hydrogen chloride concentration
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
PN-EN 1911:2011
26 Waste gases Hydrogen chloride emission (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
PN-EN 1911:2011
27 Waste gases Sampling for determination of hydrogen fluoride concentration
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
ISO 15713:2006
28 Waste gases Hydrogen fluoride emission (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
ISO 15713:2006
29 Waste gases Sampling for determination of total mercury concentration
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
PN-EN 13211:2006
30 Waste gases Total mercury emission (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
PN-EN 13211:2006
31 Waste gases Sampling for determination of metal concentrations: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
PN-EN 14385:2025-05
32 Waste gases Emission of As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
PN-EN 14385:2025-05
33 Waste gases Concentration of organic substances in the form of gases and vapours expressed as total gaseous organic carbon
Range (1,9 – 290,0) mg/m3
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Continuous flame ionization detection method (FID) PN-EN 12619:2013-05
34 Waste gases Emission of organic substances in gaseous and vapour form expressed as total gaseous organic carbon (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
PN-EN 12619:2013-05
35 Waste gases Sampling for the determination of PCDD/PCDF concentration
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Filtration-condensation method PN-EN 1948-1:2006 | PN-EN 1948-4+A1:2014-03
36 Waste gases PCDD/PCDF emission (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
PN-EN 1948-1:2006 | PN-EN 1948-4+A1:2014-03
37 Waste gases Sampling for determination of the concentration of individual gaseous organic compounds
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Method using activated carbon PN-EN 13649:2005
38 Waste gases Emission of individual gaseous organic compounds (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
PN-EN 13649:2005
39 Waste gases Sampling for determination of the dust fraction PN-Z-04030-7:1994 | Test instruction ILB/5.6/1 version 2 of 15.06.2016
40 Waste gases Emission of the dust fraction (calculated) PN-Z-04030-7:1994 | Test instruction ILB/5.6/1 version 2 of 15.06.2016
41 Waste gases Ammonia (NH3) concentration
Range (1,1 – 36) mg/m3
Fourier transform infrared spectroscopy (FTIR) ISO 10396:2007 | Test instruction ILB/5.4/.4 version 4 of 09.06.2018
42 Waste gases Ammonia (NH3) emission (calculated) ISO 10396:2007 | Test instruction ILB/5.4/.4 version 4 of 09.06.2018
43 Waste gases Sampling for the determination of ammonia (NH3) concentration PN-EN ISO 21877:2020-03
44 Waste gases Ammonia (NH3) emission (calculated) PN-EN ISO 21877:2020-03
45 Waste gases Sampling for the determination of SO3, H2SO4 concentration VDI 2462-2:2011
46 Waste gases Concentration of SO3, H2SO4
SO3 (5,0 – 50) mg/m3 H2SO4 (3,6 – 50) mg/m3
Thoron method VDI 2462-2:2011
47 Waste gases Emission of SO3, H2SO4 (calculated) VDI 2462-2:2011
48 Waste gases SO2 concentration
Range (8,0 – 2400) mg/m3
Non-dispersive infrared spectrometry (NDIR) PN-ISO 10396:2001 | Test instruction ILB/5.4/5 version 2 of 29.05.2018
49 Waste gases NO, NOx concentration
NO (2,3 – 620) mg/m3 NOx (3,6 – 950) mg/m3
Chemiluminescence method CLD PN-EN 14792:2017 | PN-ISO 10396:2001 | Test instruction ILB/5.4/5 version 2 of 29.05.2018
50 Waste gases CO concentration
Range (3,0 – 1200) mg/m3
Non-dispersive infrared spectrometry (NDIR) PN-EN 15058:2017 | PN-ISO 10396:2001 | Test instruction ILB/5.4/5 version 2 of 29.05.2018
51 Waste gases O2 concentration
Range (0,7 – 21,0) %
Paramagnetic method PN-EN 14789:2017 | PN-ISO 10396:2001 | Test instruction ILB/5.4/5 version 2 of 29.05.2018
52 Waste gases CO2 concentration
Range (0,6 – 18) %
Non-dispersive infrared spectrometry (NDIR) PN-ISO 10396:2001 | Test instruction ILB/5.4/5 version 2 of 29.05.2018
53 Waste gases Concentration of nitrogen oxide, nitrogen dioxide, sulphur dioxide, carbon dioxide
NO (5,9 – 1050) mg/m3 NO2 (4,4 – 100) mg/m3 SO2 (13,2 – 5100) mg/m3 NH3 (1,1 – 36) mg/m3 CO2 (1,0 – 22,0) % CO (2,1 – 1800) mg/m3
Fourier transform infrared spectroscopy (FTIR) PN-ISO 10396:2001 | Test instruction ILB/5.4/.4 version 4 of 09.06.2018
54 Waste gases Oxygen concentration
Range (0,9 – 21,0) %
Zirconia cell method PN-ISO 10396:2001 | Test instruction ILB/5.4/.4 version 4 of 09.06.2018
55 Waste gases Emission of NO, NO2, SO2, NH3, CO2, CO (calculated) PN-ISO 10396:2001 | Test instruction ILB/5.4/.4 version 4 of 09.06.2018
56 Waste gases Sampling for determination of metal concentrations: Se, Zn PN-EN 14385:2025-05
57 Waste gases Emission of metals: Se, Zn (calculated) PN-EN 14385:2025-05
58 Waste gases Sampling for the determination of the concentration of dioxin-like PCBs Filtration-condensation method PN-EN 1948-4+A1:2014-03
59 Waste gases Emission of dioxin-like PCB (calculated) PN-EN 1948-4+A1:2014-03
60 Waste gases Sampling for the determination of the mass concentration of PAHs Filtration-condensation-absorption method ISO 11338-1:2003
61 Waste gases PAH emission (calculated) ISO 11338-1:2003
62 Waste gases N2O concentration
Range (1,4 – 285,0) mg/m3
Non-dispersive infrared spectrometry (NDIR) PN-EN ISO 21258:2010
63 Waste gases N2O emission (calculated) PN-EN ISO 21258:2010
64 Waste gases Sampling for determination of hydrogen fluoride concentration CEN/TS 17340:2020-09
65 Waste gases Hydrogen fluoride emission (calculated) CEN/TS 17340:2020-09
66 Waste gases Sampling for determination of hydrogen sulfide concentration (H2S) Aspiration method using an absorbing solution VDI 3486 Blatt 2:1979
67 Waste gases Hydrogen sulfide (H2S) emission (calculated) VDI 3486 Blatt 2:1979
68 Automated Measuring Systems (AMS) AMS calibration (QAL2) for: dust, SO2, NO, NO2, NOx, CO, O2, CO2, H2O, organic substances in the form of gases and vapours expressed as total gaseous organic carbon, HCl, HF, Hg
Regulated area: Continuous measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
PN-EN 14181:2015
69 Automated Measuring Systems (AMS) Annual surveillance test (AST) for: dust, SO2, NO, NO2, NOx, CO, O2, CO2, H2O, organic substances in the form of gases and vapours expressed as total gaseous organic carbon, HCl, HF, Hg
Regulated area: Continuous measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
PN-EN 14181:2015
70 Automated Measuring Systems (AMS) Dust concentration
Range (0,001 – 100) g/m3
Regulated area: Continuous measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Gravimetric method PN-Z-04030-7:1994
71 Automated Measuring Systems (AMS) Dust concentration
Range (0,48 – 50) mg/m3
Regulated area: Continuous measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Gravimetric method PN-EN 13284-1:2018-02
72 Automated Measuring Systems (AMS) SO2 concentration
Range (5 – 2000) mg/m3
Regulated area: Continuous measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Thoron method PN-EN 14791:2017-04
73 Automated Measuring Systems (AMS) NO, NO2, NOx concentration
NO (2,3 – 620) mg/m3 NO2 (3,6 – 950) mg/m3 NOx (3,6 – 950) mg/m3
Regulated area: Continuous measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Chemiluminescence method PN-EN 14792:2017
74 Automated Measuring Systems (AMS) CO concentration
Range (3,0 - 1200) mg/m3
Regulated area: Continuous measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Non-dispersive infrared spectrometry (NDIR) PN-EN 15058:2017
75 Automated Measuring Systems (AMS) O2 concentration
Range (0,7 – 21) %
Regulated area: Continuous measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Paramagnetic method PN-EN 14789:2017
76 Automated Measuring Systems (AMS) Water vapour concentration (H2O)
Range (4,0 − 40) % vol. Range (3,14 – 57,41) %
Regulated area: Continuous measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Condensation- adsorption method; Temperature method PN-EN 14790:2017-04
77 Automated Measuring Systems (AMS) Concentration of organic substances in the form of gases and vapours expressed as total gaseous organic carbon
Range (1,9 – 290,0) mg/m3
Regulated area: Continuous measurements of emissions to air from stationary sources performed for the purposes of the regulated area. The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Continuous flame ionization detection method (FID) PN-EN 12619:2013-05
78 Automated Measuring Systems (AMS) Calibration of AMS (QAL2) for: NH3, N2O PN-EN 14181:2015
79 Automated Measuring Systems (AMS) Annual surveillance test (AST) for: NH3, N2O PN-EN 14181:2015
80 Automated Measuring Systems (AMS) NH3 concentration
Range (1,1 – 36) mg/m3
Fourier transform infrared spectroscopy (FTIR) ISO 10396:2007 | Test instruction ILB/5.4/.4 version 4 of 09.06.2018
81 Automated Measuring Systems (AMS) N2O concentration
Range (1,4 – 285,0) mg/m3
Non-dispersive infrared spectrometry (NDIR) PN-EN ISO 21258:2010
82 Automated Measuring Systems (AMS) N2O emission (calculated) PN-EN ISO 21258:2010
83 Automated Measuring Systems (AMS) Sampling for determination of hydrogen chloride concentration PN-EN 1911:2011
84 Automated Measuring Systems (AMS) Hydrogen chloride emission (calculated) PN-EN 1911:2011
85 Automated Measuring Systems (AMS) Sampling for determination of hydrogen fluoride concentration ISO 15713:2006 | CEN/TS 17340:2020-09
86 Automated Measuring Systems (AMS) Hydrogen fluoride emission (calculated) ISO 15713:2006 | CEN/TS 17340:2020-09
87 Automated Measuring Systems (AMS) Sampling for determination of total mercury concentration PN-EN 13211:2006
88 Automated Measuring Systems (AMS) Total mercury emission (calculated) PN-EN 13211:2006
89 Automated Measuring Systems (AMS) Sampling for determination of ammonia concentration PN-EN ISO 21877:2020-03
90 Automated Measuring Systems (AMS) Ammonia emission (calculated) PN-EN ISO 21877:2020-03
91 Automated Measuring Systems (AMS) CO2 concentration
Range (0,6 – 18) %
Non-dispersive infrared spectrometry (NDIR) ISO 10396:2007 | ISO 12039:2019
92 Machinery and equipment including cooling towers, chimneys, turbines and turbine sets – noise A-frequency-weighted sound pressure level
Range (26,0 – 136,0) dB
Direct measurement method PN-EN ISO 3746:2011 | PN-EN ISO 3746:2011+Ap1:2017-09 excluding cl. 8.4 | PN-EN ISO 3744:2011 excluding cl. 8.3 | DIN 45635-46:1985-06 | DIN 45635-47:1985-06 | ISO 10494:2018
93 Machinery and equipment including cooling towers, chimneys, turbines and turbine sets – noise Sound pressure level in 1/1 and 1/3 octave bands in the range of centre frequencies
Range (20 – 20 000) Hz
Direct measurement method PN-EN ISO 3746:2011 | PN-EN ISO 3746:2011+Ap1:2017-09 excluding cl. 8.4 | PN-EN ISO 3744:2011 excluding cl. 8.3 | DIN 45635-46:1985-06 | DIN 45635-47:1985-06 | ISO 10494:2018
94 Machinery and equipment including cooling towers, chimneys, turbines and turbine sets – noise Sound power level (calculated) PN-EN ISO 3746:2011 | PN-EN ISO 3746:2011+Ap1:2017-09 excluding cl. 8.4 | PN-EN ISO 3744:2011 excluding cl. 8.3 | DIN 45635-46:1985-06 | DIN 45635-47:1985-06 | ISO 10494:2018
95 General environment - noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level
Range (26,0 – 136,0) dB
Direct measurement method Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (Journal of Laws of 2023 item 1706)
96 General environment - noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Calculation method Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (Journal of Laws of 2023 item 1706) | PN ISO 9613-2:2002
97 Workplace environment - noise A-weighted equivalent sound pressure level
Range (26,0 – 136,0) dB
Direct measurement method PN-N-01307: 1994 | PN-EN ISO 9612:2025-11 excluding the method covering strategies 2 and 3 – cl. 10 and 11
98 Workplace environment - noise Maximum A-weighted sound pressure level
Range (26,0 – 136,0) dB
Direct measurement method PN-N-01307: 1994 | PN-EN ISO 9612:2025-11 excluding the method covering strategies 2 and 3 – cl. 10 and 11
99 Workplace environment - noise C-weighted peak sound pressure level
Range (40,0 – 138,0) dB
Direct measurement method PN-N-01307: 1994 | PN-EN ISO 9612:2025-11 excluding the method covering strategies 2 and 3 – cl. 10 and 11
100 Workplace environment - noise Noise exposure level referred to: - an 8-hour daily working time, - an average weekly working time (calculated) PN-N-01307: 1994 | PN-EN ISO 9612:2025-11 excluding the method covering strategies 2 and 3 – cl. 10 and 11

Reference standards (40)

CEN/TS 17340:2020-09
DIN 45635-46:1985-06
DIN 45635-47:1985-06
ISO 10396:2007
ISO 10494:2018
ISO 11338-1:2003
ISO 12039:2019
ISO 15713:2006
Test instruction ILB/5.4/.4 version 4 of 09.06.2018
Test instruction ILB/5.4/5 version 2 of 29.05.2018
Test instruction ILB/5.6/1 version 2 of 15.06.2016
PN ISO 9613-2:2002
PN-EN 12619:2013-05
PN-EN 13211:2006
PN-EN 13284-1:2018-02
PN-EN 13649:2005
PN-EN 14181:2015
PN-EN 14385:2025-05
PN-EN 14789:2017
PN-EN 14790:2017-04
PN-EN 14791:2017-04
PN-EN 14792:2017
PN-EN 15058:2017
PN-EN 1911:2011
PN-EN 1948-1:2006
PN-EN 1948-4+A1:2014-03
PN-EN ISO 16911-1:2013-07
PN-EN ISO 21258:2010
PN-EN ISO 21877:2020-03
PN-EN ISO 3744:2011 excluding cl. 8.3
PN-EN ISO 3746:2011
PN-EN ISO 3746:2011+Ap1:2017-09 excluding cl. 8.4
PN-EN ISO 9612:2025-11 excluding the method covering strategies 2 and 3 – cl. 10 and 11
PN-ISO 10396:2001
PN-ISO 7935:2000
PN-N-01307: 1994
PN-Z-04030-7:1994
VDI 2462-2:2011
VDI 3486 Blatt 2:1979
Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (Journal of Laws of 2023 item 1706)

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/PL/AB%201624