🇵🇱 ECOSOUND Sp. z o.o. PL

PCA AB 1598 • Kraków, Poland • 25 methods

Environment

ECOSOUND Sp. z o.o. is a laboratory accredited by PCA under number AB 1598 (Kraków, Poland). Its accreditation scope covers 25 test methods in the following areas: Environment. Test objects include: General environment – noise from airports, General environment − noise from installations, equipment and indus…, General environment − noise from roads, railway lines, tram lines, Rooms in residential, collective residence and public utility build….

At a glance

  • Accreditation number: PCA AB 1598
  • Methods in scope: 25
  • Types of test objects: 7
  • City: Kraków, Poland
Accreditation number
AB 1598
Accreditation body
PCA
Address
LABORATORIUM ECOSOUND, ul. Miechowska 5B/1, 30-055 Kraków
City
Kraków, Poland

What this laboratory tests (7)

Certificate information

Issue date
05.05.2025
Issue no.
10

Accreditation scope — test methods (25)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 General environment − noise from roads, railway lines, tram lines A-weighted equivalent sound level, A-weighted sound exposure level Range: (22 – 135) dB Direct measurement method No. 3 | …regulation of the Minister of the Environment of 16.06.2011 (Journal of Laws No. 140 | No. 288
2 General environment − noise from roads, railway lines, tram lines A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated)
3 General environment − noise from roads, railway lines, tram lines Long-term average A-weighted sound level expressed by the indices LD, LW, LN and LDWN (calculated)
4 General environment − noise from roads, railway lines, tram lines A-weighted equivalent sound level over the reference time T expressed by the indicators LAeqD and LAeqN Long-term average A-weighted sound level expressed by the indicators LD, LW, LN and LDWN Calculation method ISO 9613-2:2002 NMPB-Routes-96 NMPB-Routes-2008 NFS 31-133 (XPS 31-133) RMR/SRM II Schall 03 CNOSSOS-EU:2012 (Commission Directive (EU) 2015/996 of 19 May 2015 as amended)
5 General environment – noise from airports A-weighted equivalent sound level A-weighted sound exposure level Range: (25 – 135) dB Direct measurement method No. 1 | …regulation of the Minister of the Environment of 16.06.2011 (Journal of Laws 2011 No. 140
6 General environment – noise from airports A-weighted equivalent sound level for reference time T (calculated)
7 General environment – noise from airports Long-term average A-weighted sound level expressed by the indices LD, LW, LN and LDWN (calculated)
8 General environment – noise from airports A-weighted equivalent sound level for the reference time T Long-term average A-weighted sound level expressed by the indicators LD, LW, LN and LDWN Calculation method ECAC.CEAC Doc. 29 CNOSSOS-EU:2012 (Commission Directive (EU) 2015/996 of 19 May 2015 as amended)
9 General environment – noise from airports A-weighted equivalent sound level A-weighted sound exposure level Range: (22 – 135) dB Direct measurement method No. 2 | …regulation of the Minister of the Environment of 16.06.2011 (Journal of Laws 2011 No. 140
10 General environment – noise from airports A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated)
11 General environment – noise from airports A-weighted equivalent sound level for reference time T expressed as LAeqD and LAeqN indices Calculation method ECAC.CEAC Doc. 29 CNOSSOS-EU:2012 (Commission Directive (EU) 2015/996 of 19 May 2015 as amended)
12 General environment − noise from installations, equipment and industrial plants A-weighted equivalent sound level Range: (22 – 135) dB Direct measurement method No. 7 | …regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023, item 1706)
13 General environment − noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated)
14 General environment − noise from installations, equipment and industrial plants Long-term average A-weighted sound level expressed by the indices LD, LW, LN and LDWN (calculated)
15 General environment − noise from installations, equipment and industrial plants A-weighted equivalent sound level over the reference time T expressed by the indicators LAeqD and LAeqN Long-term average A-weighted sound level expressed by the indicators LD, LW, LN and LDWN Calculation method ISO 9613-2:2002 PN-EN ISO 12354-4:2017-10 CNOSSOS-EU:2012 (Commission Directive (EU) 2015/996 of 19 May 2015 as amended)
16 General environment − impulse noise from installations, equipment and industrial plants A-weighted equivalent sound level A-weighted maximum sound level A-weighted sound exposure level Range: (40 – 135) dB Direct measurement method No. 8 | …regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023, item 1706)
17 General environment − impulse noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated)
18 Machinery and equipment – noise A-weighted sound pressure level A-weighted single event sound pressure level Range: (22 – 135) dB Sound pressure level in 1/3 octave bands Range: (50 – 10000) Hz Direct measurement method PN-EN ISO 3744:2011 PN-EN ISO 3746:2011 PN-EN ISO 3746:2011/Ap1:2017-09
19 Machinery and equipment – noise Sound power level Sound energy level (calculated)
20 Workplace environment – noise A-weighted equivalent sound level A-weighted maximum sound level Range: (22 – 135) dB C-weighted peak sound level Range: (40 – 138) dB Direct measurement method PN-N-01307:1994 PN-EN ISO 9612:2011 excluding the method covering strategy 3 – cl. 11
21 Workplace environment – noise Noise exposure level referred to: - the 8-hour daily working time - the average weekly working time (calculated)
22 Rooms in residential, collective residence and public utility buildings – noise A-weighted equivalent sound level A-weighted maximum sound level Range: (22 – 135) dB Direct measurement method PN-87/B-02156
23 Rooms in residential, collective residence and public utility buildings – noise A-weighted equivalent sound level for reference time T (calculated)
24 Rooms in residential, collective residence and public utility buildings – noise A-weighted equivalent sound level A-weighted maximum sound level Range: (22 – 135) dB Direct measurement method PN-EN ISO 10052:2007 PN-EN ISO 10052:2007/A1:2010 PN-EN ISO 10052:2021-12
25 Rooms in residential, collective residence and public utility buildings – noise Reference A-weighted equivalent sound level for the work cycle Reference A-weighted maximum sound level for the work cycle (calculated)

Reference standards (17)

ECAC.CEAC Doc. 29 CNOSSOS-EU:2012 (Commission Directive (EU) 2015/996 of 19 May 2015 as amended)
ISO 9613-2:2002 NMPB-Routes-96 NMPB-Routes-2008 NFS 31-133 (XPS 31-133) RMR/SRM II Schall 03 CNOSSOS-EU:2012 (Commission Directive (EU) 2015/996 of 19 May 2015 as amended)
ISO 9613-2:2002 PN-EN ISO 12354-4:2017-10 CNOSSOS-EU:2012 (Commission Directive (EU) 2015/996 of 19 May 2015 as amended)
PN-87/B-02156
PN-EN ISO 10052:2007 PN-EN ISO 10052:2007/A1:2010 PN-EN ISO 10052:2021-12
PN-EN ISO 3744:2011 PN-EN ISO 3746:2011 PN-EN ISO 3746:2011/Ap1:2017-09
PN-N-01307:1994 PN-EN ISO 9612:2011 excluding the method covering strategy 3 – cl. 11
…regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023, item 1706)
…regulation of the Minister of the Environment of 16.06.2011 (Journal of Laws 2011 No. 140
…regulation of the Minister of the Environment of 16.06.2011 (Journal of Laws No. 140
…regulation of the Minister of the Environment of 16.06.2011 (Journal of Laws 2011 No. 140
No. 1
No. 2
No. 288
No. 3
No. 7
No. 8

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/PL/AB%201598