🇵🇱 LABORATORIA BADAWCZE I WZORCUJĄCE PL
ConstructionWater & wastewater
LABORATORIA BADAWCZE I WZORCUJĄCE is a laboratory accredited by PCA under number AB 1596 (Warszawa, Poland). Its accreditation scope covers 118 test methods in the following areas: Construction, Water & wastewater. Test objects include: Doors with drive, Gates, Doors, Doors and windows. Most frequently used techniques: Calculation method, Method 1, Static load method +.
At a glance
- Accreditation number: PCA AB 1596
- Methods in scope: 118
- Types of test objects: 40
- Techniques used: 3
- City: Warszawa, Poland
- Accreditation number
- AB 1596
- Accreditation body
- PCA
- Address
- CERTBUD Sp. z o.o., ul. Mokotowska 46/8, 00-543 Warszawa
- City
- Warszawa, Poland
What this laboratory tests (40)
- Doors with drive — 19 methods
- Gates — 18 methods
- Doors — 14 methods
- Doors and windows — 7 methods
- Curtain walls — 6 methods
- Doors, windows and blinds — 6 methods
- Ventilation components — 6 methods
- Building partitions with enhanced burglary resistance, including: - windows - doors - curtain walls - gates - shutters - others — 3 methods
- Partitions — 3 methods
- Doors, gates and blinds — 2 methods
- Doors, windows, gates, shutters and openable windows, related building hardware — 2 methods
- Non-loadbearing walls — 2 methods
- Building components — 1 method
- Building hardware — 1 method
- Building products/materials — 1 method
- and 25 more
Analytical techniques used (3)
- Calculation method — 7 methods
- Method 1 — 1 method
- Static load method + — 1 method
Certificate information
- Issue date
- 02.09.2026
- Issue no.
- 20
Accreditation scope — test methods (118)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Testing and Calibration Laboratories | |||||
| 1 | Doors, windows, gates, shutters and openable windows, related building hardware | Fire resistance: Fire insulation min Fire integrity min Flame retention Radiation intensity at one point Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. Test results on the basis of which the laboratory formulates opinions and interpretations are marked with the symbol "*". Type of activity / parameter / characteristic tested |
PN-EN 15269-5+A1:2016-11 | PN-EN 15269-7:2010 | PN-EN 15269-10:2011 | PN-EN 13501-2:2023-09 * | ||
| 2 | Curtain walls | Fire integrity: Fire insulation min Flame retention Openings and breakages ignition of cotton wool pad Average temperature rise Maximum temperature rise Deformation + also tests at the place indicated by the client, using the manufacturer's equipment Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. "N" – test method used in activities relevant to notification according to EU Regulation No 305/2011 of 9 March 2011. Test results on the basis of which the laboratory formulates opinions and interpretations are marked with the symbol "*". Tests performed both at the laboratory's premises and at external locations are marked with the symbol + in column 2 of the accreditation scope. Type of activity / parameter / characteristic tested |
PN-EN 1364-3:2014-03 „N" | PN-EN 1364-4:2014-04 „N" | PN-EN 1363-1:2020-07 | PN-EN 1363-2:2001 | PN-EN 13501-2:2023-09 * | ||
| 3 | Non-loadbearing walls | Fire integrity, fire insulation, resistance to mechanical impact Flame retention Openings and breakage Cotton pad ignition Average temperature rise Maximum temperature rise Deformation Radiation intensity at one point Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. Test results on the basis of which the laboratory formulates opinions and interpretations are marked with the symbol "*". Type of activity / parameter / characteristic tested |
PN-EN 15254-4:2019-01 | PN-EN 13501-2:2023-09 * | ||
| 4 | Sandwich panels | Fire resistance: Fire insulation min Fire integrity min Flame retention Radiation intensity at one point Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. "N" – test method used in activities relevant to notification according to EU Regulation No 305/2011 of 9 March 2011. Test results on the basis of which the laboratory formulates opinions and interpretations are marked with the symbol "*". Type of activity / parameter / characteristic tested |
PN-EN 14509:2013-12 cl. 5.2.4.2, C2 „N" | PN-EN 13501-2:2023-09 * | ||
| 5 | Penetration seals | Fire integrity, fire insulation Flame retention Openings and breakage Cotton pad ignition Maximum temperature rise + also tests in the place indicated by the client, using the manufacturer's equipment Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. "N" – test method used in activities relevant to notification according to EU Regulation No 305/2011 of 9 March 2011. Test results on the basis of which the laboratory formulates opinions and interpretations are marked with the symbol "*". Tests performed both at the laboratory's premises and at external locations are marked with the symbol + in column 2 of the accreditation scope. Type of activity / parameter / characteristic tested |
PN-EN 1366-3:2010 „N" | PN-EN 1366-3:2022-05 „N" | PN-EN 1366-3+A1:2025-04 „N | PN-EN 1363-1:2020-07 | PN-EN 1363-2:2001 | PN-EN 13501-2:2023-09 * | ||
| 6 | Linear joint seals | Fire integrity, fire insulation Flame retention Openings and breakage Cotton pad ignition Maximum temperature rise Movement capability + also tests in the place indicated by the client, using the manufacturer's equipment Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. "N" – test method used in activities relevant to notification according to EU Regulation No 305/2011 of 9 March 2011. Test results on the basis of which the laboratory formulates opinions and interpretations are marked with the symbol "*". Tests performed both at the laboratory's premises and at external locations are marked with the symbol + in column 2 of the accreditation scope. Type of activity / parameter / characteristic tested |
PN-EN 1366-4 + A1:2011 „N" | PN-EN 1366-4:2021- 07 „N" | PN-EN 1363-1:2020-07 | PN-EN 1363-2:2001 | PN-EN 13501-2:2023-09 * | ||
| 7 | Conveyor systems and their closures | Fire integrity, fire insulation, radiation intensity, self-closing Flame retention Openings and breakage Cotton pad ignition Average temperature rise Maximum temperature rise Self-closing ability Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. "N" – test method used in activities relevant to notification according to EU Regulation No 305/2011 of 9 March 2011. Test results on the basis of which the laboratory formulates opinions and interpretations are marked with the symbol "*". Type of activity / parameter / characteristic tested |
PN-EN 1366-7:2006 „N" | PN-EN 1363-1:2020-07 | PN-EN 1363-2:2001 | PN-EN 13501-2:2023-09 * | ||
| 8 | Light fire storage units, fire-resistant cabinets | Temperature rise inside the test sample in °C Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. Type of activity / parameter / characteristic tested |
PN-EN 15659:2009 | PN-EN 1363-1:2012 | PN-EN 1363-2:2001 | PN-EN 15659:2019-12 | NT FIRE 017, 3rd edition, approved in 09-2023 | ISO 834-1:1999 | ||
| 9 | Smoke curtains | Fire integrity – min + also tests in the place indicated by the client, using the manufacturer's equipment Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. Tests performed both at the laboratory's premises and at external locations are marked with the symbol + in column 2 of the accreditation scope. Type of activity / parameter / characteristic tested |
PN-EN 12101-1:2007, Annex D | PN-EN 1363-1:2020-07 | PN-EN 1363-2:2001 | ||
| 10 | Materials used in smoke curtains | Permeability: Flow rate + also tests at the place indicated by the client, using the manufacturer's equipment Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. Tests performed both at the laboratory's premises and at external locations are marked with the symbol + in column 2 of the accreditation scope. Type of activity / parameter / characteristic tested |
PN-EN 12101-1:2007 Annex C | PN-EN 1634-3:2006 | PN-EN 1634-3:2006/AC:2006 | ||
| 11 | Electric cables and wires | Continuity of power and signal supply – time to ensure continuity of power and/or signal supply + also tests at the place indicated by the client, using the manufacturer's equipment Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. Tests performed both at the laboratory's premises and at external locations are marked with the symbol + in column 2 of the accreditation scope. Type of activity / parameter / characteristic tested |
DIN 4102-12:1998 | DIN 4102-2:1977 | ||
| 12 | Fire partitions, protection in elevator shafts and fire partitions | Fire resistance + also tests in the place indicated by the client, using the manufacturer's equipment Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. Tests performed both at the laboratory's premises and at external locations are marked with the symbol + in column 2 of the accreditation scope. Type of activity / parameter / characteristic tested |
DIN 4102-5:1977 | DIN 4102-2:1977 | ||
| 13 | Floors and roofs | Fire resistance R, integrity, thermal insulation, radiation intensity + also tests at the place indicated by the client, using the manufacturer's equipment Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. "N" – test method used in activities relevant to notification according to EU Regulation No 305/2011 of 9 March 2011. Tests performed both at the laboratory's premises and at external locations are marked with the symbol + in column 2 of the accreditation scope. Type of activity / parameter / characteristic tested |
PN-EN 1365-2:2014-12 „N" | ||
| 14 | Elements of facade cladding | Falling-off tests under the influence of fire - in accordance with the requirements of paragraph 225 of the Technical Conditions to be met by buildings and their location Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. Type of activity / parameter / characteristic tested |
Certbud procedure S25-1 issue 1, dated 10.01.2024 | ||
| 15 | Partitions | Soft body impact Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. Type of activity / parameter / characteristic tested |
EAD 210005-00-0505 | ||
| 16 | Partitions | Hard body impact Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. Type of activity / parameter / characteristic tested |
EAD 210005-00-0505 | ||
| 17 | Partitions | Resistance to horizontal linear static load Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. Type of activity / parameter / characteristic tested |
EAD 210005-00-0505 | ||
| 18 | Doors | Ability to release (open) Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. Type of activity / parameter / characteristic tested |
R9-P22-LBiW issue of 09.01.2021 | NB-CPD/SG06/11/0084 | PN-EN 14351-1+A2:2016-1 cl. 4.10 | PN-EN 14351-2:2018-12 cl. 4.10, 5.10 | ||
| 19 | Doors | Height measurement Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. Type of activity / parameter / characteristic tested |
PN-EN 14351-2:2018-12 cl. 5.4 | ||
| 20 | Doors | Assessment of thermal properties Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. Type of activity / parameter / characteristic tested |
PN-EN 14351-2:2018-12 cl. 5.8.2 | ||
| 21 | Doors | Air permeability + Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. Tests performed both at the laboratory's premises and at external locations are marked with the symbol + in column 2 of the accreditation scope. Type of activity / parameter / characteristic tested |
PN-EN 14351-2:2018-12 cl. 5.9 | ||
| 22 | Doors | Ability to release Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. Type of activity / parameter / characteristic tested |
PN-EN 14351-2:2018-12 cl. 5.10 | ||
| 23 | Doors | Measurement of height, width, thickness and squareness Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. Type of activity / parameter / characteristic tested |
PN-EN 951:2000 | ||
| 24 | Doors | General and local flatness deviation from general, linear and local flatness Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. Type of activity / parameter / characteristic tested |
PN-EN 952:2000 | ||
| 25 | Doors, windows and blinds | Resistance to repeated closing and opening Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. Test results on the basis of which the laboratory formulates opinions and interpretations are marked with the symbol "*". Type of activity / parameter / characteristic tested |
PN-EN 170204:2021-10 * | EN 170201:2022 * | EN 17020-2:2022 * | EN 17020-3:2022 * | EN 17020-5:2023 * | ||
| 26 | Doors, windows and blinds | Durability of self-closing Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. Test results on the basis of which the laboratory formulates opinions and interpretations are marked with the symbol "*". Type of activity / parameter / characteristic tested |
PN-EN 17020-4:2021-10* | ||
| 27 | Doors, windows and blinds | Air permeability + Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. Tests performed both at the laboratory's premises and at external locations are marked with the symbol + in column 2 of the accreditation scope. Type of activity / parameter / characteristic tested |
PN-EN 1026:2001 | ||
| 28 | Doors, windows and blinds | Water tightness + Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. Tests performed both at the laboratory's premises and at external locations are marked with the symbol + in column 2 of the accreditation scope. Type of activity / parameter / characteristic tested |
PN-EN 1027:2001 | ||
| 29 | Doors, windows and blinds | Resistance to wind load + Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. Tests performed both at the laboratory's premises and at external locations are marked with the symbol + in column 2 of the accreditation scope. Type of activity / parameter / characteristic tested |
PN-EN 12211:2001 | ||
| 30 | Doors, windows and blinds | Impact test method/impact resistance + Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. Tests performed both at the laboratory's premises and at external locations are marked with the symbol + in column 2 of the accreditation scope. Type of activity / parameter / characteristic tested |
PN-EN 12600:2004 | PN-EN 14351-2:2018-12 cl. 5.3 | ||
| 31 | Doors with drive | Soft and heavy body impact + Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. Tests performed both at the laboratory's premises and at external locations are marked with the symbol + in column 2 of the accreditation scope. Type of activity / parameter / characteristic tested |
PN-EN 16361+A1:2016-08 cl. 4.3 | ||
| 32 | Doors with drive | Height + Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. Tests performed both at the laboratory's premises and at external locations are marked with the symbol + in column 2 of the accreditation scope. Type of activity / parameter / characteristic tested |
PN-EN 16361+A1:2016-08 cl. 4.4 | ||
| 33 | Doors with drive | Water tightness + Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. Tests performed both at the laboratory's premises and at external locations are marked with the symbol + in column 2 of the accreditation scope. Type of activity / parameter / characteristic tested |
PN-EN 16361+A1:2016-08 cl. 4.7 | ||
| 34 | Doors with drive | Resistance to wind load + Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. Tests performed both at the laboratory's premises and at external locations are marked with the symbol + in column 2 of the accreditation scope. Type of activity / parameter / characteristic tested |
PN-EN 16361+A1:2016-08 cl. 4.8 | ||
| 35 | Doors with drive | Air permeability + Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. Tests performed both at the laboratory's premises and at external locations are marked with the symbol + in column 2 of the accreditation scope. Type of activity / parameter / characteristic tested |
PN-EN 16361+A1:2016-08 cl. 4.10 | ||
| 36 | Doors with drive | Durability + Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. Tests performed both at the laboratory's premises and at external locations are marked with the symbol + in column 2 of the accreditation scope. Type of activity / parameter / characteristic tested |
PN-EN 16361+A1:2016-08 cl. 4.12 | ||
| 37 | Doors with drive | Impact forces (safety in use) + Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. Tests performed both at the laboratory's premises and at external locations are marked with the symbol + in column 2 of the accreditation scope. Type of activity / parameter / characteristic tested |
PN-EN 16361+A1:2016-08 cl. 4.6 | ||
| 38 | Doors with drive | Evacuation ability + Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. Tests performed both at the laboratory's premises and at external locations are marked with the symbol + in column 2 of the accreditation scope. Type of activity / parameter / characteristic tested |
PN-EN 16361+A1:2016-08 cl. 4.14.3 | ||
| 39 | Doors with drive | Impact forces (safety in use) + Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. Tests performed both at the laboratory's premises and at external locations are marked with the symbol + in column 2 of the accreditation scope. Type of activity / parameter / characteristic tested |
PN-EN 16005:2013-04 cl. 4.6.7 | ||
| 40 | Doors with drive | Durability + Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. Tests performed both at the laboratory's premises and at external locations are marked with the symbol + in column 2 of the accreditation scope. Type of activity / parameter / characteristic tested |
PN-EN 16005:2013-04 cl. 5.8 | ||
| 41 | Doors with drive | Stopping, switching off the drive + Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. Tests performed both at the laboratory's premises and at external locations are marked with the symbol + in column 2 of the accreditation scope. Type of activity / parameter / characteristic tested |
PN-EN 16005:2013-04 cl. 4.3.2 | Certbud procedure S23A-1, issue dated 30.07.2021 | ||
| 42 | Doors with drive | Emergency opening + Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. Tests performed both at the laboratory's premises and at external locations are marked with the symbol + in column 2 of the accreditation scope. Type of activity / parameter / characteristic tested |
PN-EN 16005:2013-04 cl. 4.7.2.2 | ||
| 43 | Doors with drive | Safety distances of the leaves + Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. Tests performed both at the laboratory's premises and at external locations are marked with the symbol + in column 2 of the accreditation scope. Type of activity / parameter / characteristic tested |
PN-EN 16005:2013-04 cl. 4.6.11 | ||
| 44 | Doors with drive | Avoidance and protection – danger points + Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. Tests performed both at the laboratory's premises and at external locations are marked with the symbol + in column 2 of the accreditation scope. Type of activity / parameter / characteristic tested |
PN-EN 16005:2013-04 cl. 4.6.1; 4.6.2; 4.6.3; 4.6.5; 4.6.6 | ||
| 45 | Doors with drive | Movement speed + Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. Tests performed both at the laboratory's premises and at external locations are marked with the symbol + in column 2 of the accreditation scope. Type of activity / parameter / characteristic tested |
Certbud procedure S23H-1a, issue dated 30.07.2021 | Certbud procedure S23H-1b, issue dated 30.07.2021 | ||
| 46 | Doors with drive | Operating mode + Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. Tests performed both at the laboratory's premises and at external locations are marked with the symbol + in column 2 of the accreditation scope. Type of activity / parameter / characteristic tested |
PN-EN 16005:2013-04 cl. 4.7.2.1 | ||
| 47 | Doors with drive | Activation, drive trigger area + Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. Tests performed both at the laboratory's premises and at external locations are marked with the symbol + in column 2 of the accreditation scope. Type of activity / parameter / characteristic tested |
PN-EN 16005:2013-04 cl. 4.5 | ||
| 48 | Doors with drive | Materials, shape of leaves, devices limiting the movement of the leaves + Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. Tests performed both at the laboratory's premises and at external locations are marked with the symbol + in column 2 of the accreditation scope. Type of activity / parameter / characteristic tested |
PN-EN 16005:2013-04 cl. 4.4.2; 4.4.3; 4.4.4 | ||
| 49 | Doors with drive | Opening time + Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. Tests performed both at the laboratory's premises and at external locations are marked with the symbol + in column 2 of the accreditation scope. Type of activity / parameter / characteristic tested |
PN-EN 16005:2013-04 cl. 4.7.2.3 | ||
| 50 | Windows or rooflights projecting beyond the face of partitions | Thermal transmittance Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. "N" – test method used in activities relevant to notification according to EU Regulation No 305/2011 of 9 March 2011. Type of activity / parameter / characteristic tested |
Calculation method | PN-EN ISO 10211:2017-09 „N” | PN-EN 1873+A1:2016-03 | PN-EN 1873:2006 „N” | |
| 51 | Doors, windows, roof windows, flaps, non-loadbearing walls, gates | Thermal transmittance Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. "N" – test method used in activities relevant to notification according to EU Regulation No 305/2011 of 9 March 2011. Type of activity / parameter / characteristic tested |
Calculation method | PN-EN ISO 10077-1:2007 „N” | PN-EN ISO 10077-1:2017-10 „N” | PN-EN ISO 10077-2:2017-10 | PN-EN ISO 10077- 2:2017- 10/A1:2025- 06 „N” | PN-EN ISO 10077-2:2012 | PN-EN 14351-1+A2:2016-10 „N” | PN-EN 14351-2:2018-12 | PN-EN 16361+A1:2016-08 | PN-EN 13241:2003+A2:2016 „N” | |
| 52 | Building partitions with enhanced burglary resistance, including: - windows - doors - curtain walls - gates - shutters - others | Resistance under static loading Classes RC2 – RC6 / RC2-RC6 Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. Test results on the basis of which the laboratory formulates opinions and interpretations are marked with the symbol "*". Type of activity / parameter / characteristic tested |
PN-EN 1628:2021-11 | PN-EN 1627:2021-11 * | ||
| 53 | Building partitions with enhanced burglary resistance, including: - windows - doors - curtain walls - gates - shutters - others | Resistance under dynamic loading Classes RC2 – RC3 / RC2-RC3 Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. Test results on the basis of which the laboratory formulates opinions and interpretations are marked with the symbol "*". Type of activity / parameter / characteristic tested |
PN-EN 1629:2021-11 | PN-EN 1627:2021-11 * | ||
| 54 | Building partitions with enhanced burglary resistance, including: - windows - doors - curtain walls - gates - shutters - others | Resistance to manual burglary attempts Classes RC2 – RC6 / RC2-RC6 Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. Test results on the basis of which the laboratory formulates opinions and interpretations are marked with the symbol "*". Type of activity / parameter / characteristic tested |
PN-EN 1630:2021-11 | PN-EN 1627:2021-11 * | ||
| 55 | Sections of window and door frames and their connections with glazing, shutters, shutter boxes, gates | Thermal transmittance Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. "N" – test method used in activities relevant to notification according to EU Regulation No 305/2011 of 9 March 2011. Type of activity / parameter / characteristic tested |
Calculation method | PN-EN ISO 10077-2:2017-10 „N” | PN-EN ISO 10077- 2:2017- 10/A1:2025- 06 „N” | PN-EN ISO 10077-2:2012 „N” | PN-EN ISO 10211:2017-09 | PN-EN 14351-2:2018-12 | PN-EN 14351-1+A2:2016 „N” | PN-EN 13241:2003+A2:2016 „N” | PN-EN 12428:2013-06 „N” | |
| 56 | Curtain walls | Thermal transmittance Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. "N" – test method used in activities relevant to notification according to EU Regulation No 305/2011 of 9 March 2011. Type of activity / parameter / characteristic tested |
Calculation method | PN-EN 13830:2005 cl. 4.7 „N” | PN-EN 13947:2008 „N” | PN-EN 13830+A1:2020-11 cl. 4.14, 5.14 | PN-EN ISO 12631:2017-10 | |
| 57 | Sandwich panels with metal facings | Thermal transmittance Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. "N" – test method used in activities relevant to notification according to EU Regulation No 305/2011 of 9 March 2011. Type of activity / parameter / characteristic tested |
Calculation method | PN-EN 14509:2013 „N” | PN-EN ISO 6946:2017-10 „N” | |
| 58 | Glass | Measurement of thickness + Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. Tests performed both at the laboratory's premises and at external locations are marked with the symbol + in column 2 of the accreditation scope. Type of activity / parameter / characteristic tested |
PN-EN ISO 12543-5:2011 cl. 4.1.3 | PN-EN ISO 12543-5:2022-05 cl. 4.1.3 | ||
| 59 | Glass panes | Thermal transmittance Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. "N" – test method used in activities relevant to notification according to EU Regulation No 305/2011 of 9 March 2011. Type of activity / parameter / characteristic tested |
Calculation method | PN-EN 673:2011 „N” | PN-EN 1279-5:2018 „N” | PN-EN 1863-2:2004 „N” | PN-EN 12150-2:2006 „N” | PN-EN 14449:2008 „N” | |
| 60 | Building components | Thermal transmittance Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. Type of activity / parameter / characteristic tested |
Calculation method | PN-EN ISO 10211:2017-09 | PN-EN ISO 6946:2017-10 | |
| 61 | Doors, gates and blinds | Smoke control, self-closing Flow rate Self-closing Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. Type of activity / parameter / characteristic tested |
PN-EN 15269-20:2021-02 | DIN 18095-2:1991-03 | ||
| 62 | Roofs | Resistance of roofs to external fire Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. "N" – test method used in activities relevant to notification according to EU Regulation No 305/2011 of 9 March 2011. Type of activity / parameter / characteristic tested |
Method 1 | PN-ENV 1187:2004+A1:2007 „N” | PKN-CEN/TS 1187:2014-03 “N” | |
| 63 | Building products/materials | Sampling Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. Type of activity / parameter / characteristic tested |
PN-83/N-03010 | NB-CPR/15/639 | ||
| 64 | Doors and windows | Durability of self-closing Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. Type of activity / parameter / characteristic tested |
DIN 4102-18:1991-03 | ||
| 65 | Gates | Ability to release + Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. Tests performed both at the laboratory's premises and at external locations are marked with the symbol + in column 2 of the accreditation scope. Type of activity / parameter / characteristic tested |
PN-EN 16034:2014 | ||
| 66 | Gates | Durability tests + Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. "N" – test method used in activities relevant to notification according to EU Regulation No 305/2011 of 9 March 2011. Tests performed both at the laboratory's premises and at external locations are marked with the symbol + in column 2 of the accreditation scope. Type of activity / parameter / characteristic tested |
PN-EN 12605:2002 cl. 5.2 „N” | ||
| 67 | Gates | Functional tests + Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. "N" – test method used in activities relevant to notification according to EU Regulation No 305/2011 of 9 March 2011. Tests performed both at the laboratory's premises and at external locations are marked with the symbol + in column 2 of the accreditation scope. Type of activity / parameter / characteristic tested |
PN-EN 12605:2002 cl. 5.1 „N” | ||
| 68 | Gates | Verification of the leaf anti-fall device + Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. "N" – test method used in activities relevant to notification according to EU Regulation No 305/2011 of 9 March 2011. Tests performed both at the laboratory's premises and at external locations are marked with the symbol + in column 2 of the accreditation scope. Type of activity / parameter / characteristic tested |
PN-EN 12605:2002 cl. 5.3.2 „N” | ||
| 69 | Gates | Verification of protection against falling achieved by other structural measures + Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. "N" – test method used in activities relevant to notification according to EU Regulation No 305/2011 of 9 March 2011. Tests performed both at the laboratory's premises and at external locations are marked with the symbol + in column 2 of the accreditation scope. Type of activity / parameter / characteristic tested |
PN-EN 12605:2002 cl. 5.4.3 „N” | ||
| 70 | Gates | Verification of protection against disengagement or derailment + Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. "N" – test method used in activities relevant to notification according to EU Regulation No 305/2011 of 9 March 2011. Tests performed both at the laboratory's premises and at external locations are marked with the symbol + in column 2 of the accreditation scope. Type of activity / parameter / characteristic tested |
PN-EN 12605:2002 cl. 5.1.2 „N” | ||
| 71 | Gates | Disconnection or derailment during use and operation + Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. "N" – test method used in activities relevant to notification according to EU Regulation No 305/2011 of 9 March 2011. Tests performed both at the laboratory's premises and at external locations are marked with the symbol + in column 2 of the accreditation scope. Type of activity / parameter / characteristic tested |
PN-EN 12605:2002 cl. 5.4.2 „N” | ||
| 72 | Gates | Impact test method + Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. "N" – test method used in activities relevant to notification according to EU Regulation No 305/2011 of 9 March 2011. Tests performed both at the laboratory's premises and at external locations are marked with the symbol + in column 2 of the accreditation scope. Type of activity / parameter / characteristic tested |
PN-EN 12605:2002 cl. 5.3.1 „N” | PN-EN 12600:2004 | ||
| 73 | Gates | Verification of the gate's ability to operate + Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. "N" – test method used in activities relevant to notification according to EU Regulation No 305/2011 of 9 March 2011. Tests performed both at the laboratory's premises and at external locations are marked with the symbol + in column 2 of the accreditation scope. Type of activity / parameter / characteristic tested |
PN-EN 12605:2002 cl. 5.1.1 „N” | ||
| 74 | Gates | Strength + Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. "N" – test method used in activities relevant to notification according to EU Regulation No 305/2011 of 9 March 2011. Tests performed both at the laboratory's premises and at external locations are marked with the symbol + in column 2 of the accreditation scope. Type of activity / parameter / characteristic tested |
PN-EN 12605:2002 cl. 5.4.1 „N” | ||
| 75 | Gates | Forces measurement + Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. "N" – test method used in activities relevant to notification according to EU Regulation No 305/2011 of 9 March 2011. Tests performed both at the laboratory's premises and at external locations are marked with the symbol + in column 2 of the accreditation scope. Type of activity / parameter / characteristic tested |
PN-EN 12445:2002 cl. 5 „N” | ||
| 76 | Gates | Testing of the presence detection system used without a force limiter + Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. "N" – test method used in activities relevant to notification according to EU Regulation No 305/2011 of 9 March 2011. Tests performed both at the laboratory's premises and at external locations are marked with the symbol + in column 2 of the accreditation scope. Type of activity / parameter / characteristic tested |
PN-EN 12445:2002 cl. 7.3 „N” | ||
| 77 | Gates | Dead man's control + Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. "N" – test method used in activities relevant to notification according to EU Regulation No 305/2011 of 9 March 2011. Tests performed both at the laboratory's premises and at external locations are marked with the symbol + in column 2 of the accreditation scope. Type of activity / parameter / characteristic tested |
PN-EN 12445:2002 cl. 4.1.1.4 „N” | ||
| 78 | Ventilation components | Strength, stiffness + Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. Tests performed both at the laboratory's premises and at external locations are marked with the symbol + in column 2 of the accreditation scope. Type of activity / parameter / characteristic tested |
PN-B 03434:1999 | ||
| 79 | Ventilation components | Dimensions of ventilation ducts + Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. Test results on the basis of which the laboratory formulates opinions and interpretations are marked with the symbol "*". Tests performed both at the laboratory's premises and at external locations are marked with the symbol + in column 2 of the accreditation scope. Type of activity / parameter / characteristic tested |
PN-EN 1505:2001 * | WO-KOT/36/01 issue 3 Table 1 cl. 3 * | ||
| 80 | Ventilation components | Ventilation duct wall thickness + Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. Test results on the basis of which the laboratory formulates opinions and interpretations are marked with the symbol "*". Tests performed both at the laboratory's premises and at external locations are marked with the symbol + in column 2 of the accreditation scope. Type of activity / parameter / characteristic tested |
PN-EN 10131:2008 cl. 6 * | WO-KOT/36/01 issue 3 Table 1 cl. 4* | ||
| 81 | Ventilation components | Area of the ventilation duct + Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. Test results on the basis of which the laboratory formulates opinions and interpretations are marked with the symbol "*". Tests performed both at the laboratory's premises and at external locations are marked with the symbol + in column 2 of the accreditation scope. "O" – the competence of the laboratory to assess the performance of the product on the basis of calculations has been confirmed. Type of activity / parameter / characteristic tested |
PN-EN 14239:2004 *„O” | WO-KOT/36/01 issue 3 Table 1 cl. 3 * | ||
| 82 | Paints and varnishes | Determination of coating thickness Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. Type of activity / parameter / characteristic tested |
PN-EN ISO 2808:2020-01 Methods 7B.2, 7C | ||
| 83 | Doors, windows, gates, shutters and openable windows, related building hardware | Fire resistance: Fire insulation min Fire integrity min Flame retention Radiation intensity at one point + also tests at the place indicated by the client, using the manufacturer's equipment Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. "N" – test method used in activities relevant to notification according to EU Regulation No 305/2011 of 9 March 2011. E – Flexible scope of accreditation. The flexibility of the scope covers the elements specified in document DA-10 for the scope of accreditation of testing laboratories. A list of activities carried out under the flexible scope of accreditation is made available to the public or upon request by the accredited body. Test results on the basis of which the laboratory formulates opinions and interpretations are marked with the symbol "*". Tests performed both at the laboratory's premises and at external locations are marked with the symbol + in column 2 of the accreditation scope. Type of activity / parameter / characteristic tested |
PN-EN 1634-1 „N" * | PN-EN 1363-1 | PN-EN 1363-2 | PN-EN 15269-2 * | PN-EN 15269-3 * | PN-EN 15269-11 * | ||
| 84 | Non-loadbearing walls | Fire integrity, fire insulation, resistance to mechanical impact Flame retention Openings and breakage Cotton pad ignition Average temperature rise Maximum temperature rise Deformation Radiation intensity at one point + also tests at the place indicated by the client, using the manufacturer's equipment Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. "N" – test method used in activities relevant to notification according to EU Regulation No 305/2011 of 9 March 2011. E – Flexible scope of accreditation. The flexibility of the scope covers the elements specified in document DA-10 for the scope of accreditation of testing laboratories. A list of activities carried out under the flexible scope of accreditation is made available to the public or upon request by the accredited body. Test results on the basis of which the laboratory formulates opinions and interpretations are marked with the symbol "*". Tests performed both at the laboratory's premises and at external locations are marked with the symbol + in column 2 of the accreditation scope. Type of activity / parameter / characteristic tested |
PN-EN 1364-1 „N" * | PN-EN 1363-1 | PN-EN 1363-2 | PN-EN 15254-5 * | ||
| 85 | Building hardware | Suitability for use in fire-resistant/smoke control doors Fire integrity Fire insulation risk of ignition Maintaining closing force Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. E – Flexible scope of accreditation. The flexibility of the scope covers the elements specified in document DA-10 for the scope of accreditation of testing laboratories. A list of activities carried out under the flexible scope of accreditation is made available to the public or upon request by the accredited body. Test results on the basis of which the laboratory formulates opinions and interpretations are marked with the symbol "*". Type of activity / parameter / characteristic tested |
PN-EN 1634-2 * | PN-EN 1363-1 * | PN-EN 1363-2 * | ||
| 86 | Doors, gates and blinds | Smoke control, self-closing Flow rate Self-closing + Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. "N" – test method used in activities relevant to notification according to EU Regulation No 305/2011 of 9 March 2011. E – Flexible scope of accreditation. The flexibility of the scope covers the elements specified in document DA-10 for the scope of accreditation of testing laboratories. A list of activities carried out under the flexible scope of accreditation is made available to the public or upon request by the accredited body. Tests performed both at the laboratory's premises and at external locations are marked with the symbol + in column 2 of the accreditation scope. Type of activity / parameter / characteristic tested |
PN-EN 1634-3 „N" | ||
| 87 | Curtain walls | Resistance to wind load + Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. "N" – test method used in activities relevant to notification according to EU Regulation No 305/2011 of 9 March 2011. E – Flexible scope of accreditation. The flexibility of the scope covers the elements specified in document DA-10 for the scope of accreditation of testing laboratories. A list of activities carried out under the flexible scope of accreditation is made available to the public or upon request by the accredited body. Tests performed both at the laboratory's premises and at external locations are marked with the symbol + in column 2 of the accreditation scope. Type of activity / parameter / characteristic tested |
PN-EN 12179 „N’’ | PN-EN 13116 „N’’ | ||
| 88 | Curtain walls | Water tightness + Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. "N" – test method used in activities relevant to notification according to EU Regulation No 305/2011 of 9 March 2011. E – Flexible scope of accreditation. The flexibility of the scope covers the elements specified in document DA-10 for the scope of accreditation of testing laboratories. A list of activities carried out under the flexible scope of accreditation is made available to the public or upon request by the accredited body. Tests performed both at the laboratory's premises and at external locations are marked with the symbol + in column 2 of the accreditation scope. Type of activity / parameter / characteristic tested |
PN-EN 12155 „N’’ | PN-EN 12154 „N’’ | ||
| 89 | Curtain walls | Air permeability + Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. "N" – test method used in activities relevant to notification according to EU Regulation No 305/2011 of 9 March 2011. E – Flexible scope of accreditation. The flexibility of the scope covers the elements specified in document DA-10 for the scope of accreditation of testing laboratories. A list of activities carried out under the flexible scope of accreditation is made available to the public or upon request by the accredited body. Tests performed both at the laboratory's premises and at external locations are marked with the symbol + in column 2 of the accreditation scope. Type of activity / parameter / characteristic tested |
PN-EN 12153 „N’’ | PN-EN 12152 „N’’ | ||
| 90 | Doors | Resistance to vertical load Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. E – Flexible scope of accreditation. The flexibility of the scope covers the elements specified in document DA-10 for the scope of accreditation of testing laboratories. A list of activities carried out under the flexible scope of accreditation is made available to the public or upon request by the accredited body. Test results on the basis of which the laboratory formulates opinions and interpretations are marked with the symbol "*". Tests performed both at the laboratory's premises and at external locations are marked with the symbol + in column 2 of the accreditation scope. Type of activity / parameter / characteristic tested |
Static load method + | PN-EN 947 | PN-EN 1192 * | |
| 91 | Doors | Operational forces Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. E – Flexible scope of accreditation. The flexibility of the scope covers the elements specified in document DA-10 for the scope of accreditation of testing laboratories. A list of activities carried out under the flexible scope of accreditation is made available to the public or upon request by the accredited body. Type of activity / parameter / characteristic tested |
PN-EN 12046-2 | PN-EN 12217 | ||
| 92 | Doors | Ability to release Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. E – Flexible scope of accreditation. The flexibility of the scope covers the elements specified in document DA-10 for the scope of accreditation of testing laboratories. A list of activities carried out under the flexible scope of accreditation is made available to the public or upon request by the accredited body. Type of activity / parameter / characteristic tested |
PN-EN 16034 | ||
| 93 | Doors | Resistance to soft and heavy body impact + Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. E – Flexible scope of accreditation. The flexibility of the scope covers the elements specified in document DA-10 for the scope of accreditation of testing laboratories. A list of activities carried out under the flexible scope of accreditation is made available to the public or upon request by the accredited body. Test results on the basis of which the laboratory formulates opinions and interpretations are marked with the symbol "*". Tests performed both at the laboratory's premises and at external locations are marked with the symbol + in column 2 of the accreditation scope. Type of activity / parameter / characteristic tested |
PN-EN 949 | PN-EN 1192:2001 * | ||
| 94 | Doors | Resistance to static torsion + Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. "N" – test method used in activities relevant to notification according to EU Regulation No 305/2011 of 9 March 2011. E – Flexible scope of accreditation. The flexibility of the scope covers the elements specified in document DA-10 for the scope of accreditation of testing laboratories. A list of activities carried out under the flexible scope of accreditation is made available to the public or upon request by the accredited body. Test results on the basis of which the laboratory formulates opinions and interpretations are marked with the symbol "*". Tests performed both at the laboratory's premises and at external locations are marked with the symbol + in column 2 of the accreditation scope. Type of activity / parameter / characteristic tested |
PN-EN 948 „N" | PN-EN 1192:2001 * | ||
| 95 | Doors | Resistance to vertical load + Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. E – Flexible scope of accreditation. The flexibility of the scope covers the elements specified in document DA-10 for the scope of accreditation of testing laboratories. A list of activities carried out under the flexible scope of accreditation is made available to the public or upon request by the accredited body. Tests performed both at the laboratory's premises and at external locations are marked with the symbol + in column 2 of the accreditation scope. Type of activity / parameter / characteristic tested |
PN-EN 947 | ||
| 96 | Doors | Resistance to hard body impact + Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. E – Flexible scope of accreditation. The flexibility of the scope covers the elements specified in document DA-10 for the scope of accreditation of testing laboratories. A list of activities carried out under the flexible scope of accreditation is made available to the public or upon request by the accredited body. Test results on the basis of which the laboratory formulates opinions and interpretations are marked with the symbol "*". Tests performed both at the laboratory's premises and at external locations are marked with the symbol + in column 2 of the accreditation scope. Type of activity / parameter / characteristic tested |
PN-EN 950 | PN-EN 1192:2001 * | ||
| 97 | Doors, windows and shutters | Impact test method/ impact resistance Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. E – Flexible scope of accreditation. The flexibility of the scope covers the elements specified in document DA-10 for the scope of accreditation of testing laboratories. A list of activities carried out under the flexible scope of accreditation is made available to the public or upon request by the accredited body. Type of activity / parameter / characteristic tested |
PN-EN 13049 | ||
| 98 | Doors, gates and shutters | Smoke control, self-closing, flow rate, Self-closing + Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. E – Flexible scope of accreditation. The flexibility of the scope covers the elements specified in document DA-10 for the scope of accreditation of testing laboratories. A list of activities carried out under the flexible scope of accreditation is made available to the public or upon request by the accredited body. Tests performed both at the laboratory's premises and at external locations are marked with the symbol + in column 2 of the accreditation scope. Type of activity / parameter / characteristic tested |
PN-EN 1634-3 | ||
| 99 | Doors and windows | Resistance to repeated closing and opening + Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. E – Flexible scope of accreditation. The flexibility of the scope covers the elements specified in document DA-10 for the scope of accreditation of testing laboratories. A list of activities carried out under the flexible scope of accreditation is made available to the public or upon request by the accredited body. Test results on the basis of which the laboratory formulates opinions and interpretations are marked with the symbol "*". Tests performed both at the laboratory's premises and at external locations are marked with the symbol + in column 2 of the accreditation scope. Type of activity / parameter / characteristic tested |
PN-EN 1191 | PN-EN 12400:2004 * | ||
| 100 | Doors and windows | Self-closing + Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. E – Flexible scope of accreditation. The flexibility of the scope covers the elements specified in document DA-10 for the scope of accreditation of testing laboratories. A list of activities carried out under the flexible scope of accreditation is made available to the public or upon request by the accredited body. Tests performed both at the laboratory's premises and at external locations are marked with the symbol + in column 2 of the accreditation scope. Type of activity / parameter / characteristic tested |
PN-EN 16034 | ||
| 101 | Doors and windows | Durability of self-closing + Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. E – Flexible scope of accreditation. The flexibility of the scope covers the elements specified in document DA-10 for the scope of accreditation of testing laboratories. A list of activities carried out under the flexible scope of accreditation is made available to the public or upon request by the accredited body. Tests performed both at the laboratory's premises and at external locations are marked with the symbol + in column 2 of the accreditation scope. Type of activity / parameter / characteristic tested |
PN-EN 16034 | ||
| 102 | Doors and windows | Air permeability + Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. "N" – test method used in activities relevant to notification according to EU Regulation No 305/2011 of 9 March 2011. E – Flexible scope of accreditation. The flexibility of the scope covers the elements specified in document DA-10 for the scope of accreditation of testing laboratories. A list of activities carried out under the flexible scope of accreditation is made available to the public or upon request by the accredited body. Tests performed both at the laboratory's premises and at external locations are marked with the symbol + in column 2 of the accreditation scope. Type of activity / parameter / characteristic tested |
PN-EN 1026 „N” | ||
| 103 | Doors and windows | Water tightness + Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. "N" – test method used in activities relevant to notification according to EU Regulation No 305/2011 of 9 March 2011. E – Flexible scope of accreditation. The flexibility of the scope covers the elements specified in document DA-10 for the scope of accreditation of testing laboratories. A list of activities carried out under the flexible scope of accreditation is made available to the public or upon request by the accredited body. Tests performed both at the laboratory's premises and at external locations are marked with the symbol + in column 2 of the accreditation scope. Type of activity / parameter / characteristic tested |
PN-EN 1027 „N” | ||
| 104 | Doors and windows | Resistance to wind load + Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. "N" – test method used in activities relevant to notification according to EU Regulation No 305/2011 of 9 March 2011. E – Flexible scope of accreditation. The flexibility of the scope covers the elements specified in document DA-10 for the scope of accreditation of testing laboratories. A list of activities carried out under the flexible scope of accreditation is made available to the public or upon request by the accredited body. Tests performed both at the laboratory's premises and at external locations are marked with the symbol + in column 2 of the accreditation scope. Type of activity / parameter / characteristic tested |
PN-EN 12211 „N” | ||
| 105 | Gates | Resistance to wind load + Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. "N" – test method used in activities relevant to notification according to EU Regulation No 305/2011 of 9 March 2011. E – Flexible scope of accreditation. The flexibility of the scope covers the elements specified in document DA-10 for the scope of accreditation of testing laboratories. A list of activities carried out under the flexible scope of accreditation is made available to the public or upon request by the accredited body. Tests performed both at the laboratory's premises and at external locations are marked with the symbol + in column 2 of the accreditation scope. Type of activity / parameter / characteristic tested |
PN-EN 12444 „N” | PN-EN 12424 „N” | ||
| 106 | Gates | Air permeability + Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. "N" – test method used in activities relevant to notification according to EU Regulation No 305/2011 of 9 March 2011. E – Flexible scope of accreditation. The flexibility of the scope covers the elements specified in document DA-10 for the scope of accreditation of testing laboratories. A list of activities carried out under the flexible scope of accreditation is made available to the public or upon request by the accredited body. Tests performed both at the laboratory's premises and at external locations are marked with the symbol + in column 2 of the accreditation scope. Type of activity / parameter / characteristic tested |
PN-EN 12427 „N” | PN-EN 12426 „N” | ||
| 107 | Gates | Resistance to water penetration + Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. "N" – test method used in activities relevant to notification according to EU Regulation No 305/2011 of 9 March 2011. E – Flexible scope of accreditation. The flexibility of the scope covers the elements specified in document DA-10 for the scope of accreditation of testing laboratories. A list of activities carried out under the flexible scope of accreditation is made available to the public or upon request by the accredited body. Tests performed both at the laboratory's premises and at external locations are marked with the symbol + in column 2 of the accreditation scope. Type of activity / parameter / characteristic tested |
PN-EN 12489 „N” | PN-EN 12425 „N” | ||
| 108 | Gates | Self-closing + Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. E – Flexible scope of accreditation. The flexibility of the scope covers the elements specified in document DA-10 for the scope of accreditation of testing laboratories. A list of activities carried out under the flexible scope of accreditation is made available to the public or upon request by the accredited body. Tests performed both at the laboratory's premises and at external locations are marked with the symbol + in column 2 of the accreditation scope. Type of activity / parameter / characteristic tested |
PN-EN 16034 | ||
| 109 | Gates | Durability of self-closing + Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. E – Flexible scope of accreditation. The flexibility of the scope covers the elements specified in document DA-10 for the scope of accreditation of testing laboratories. A list of activities carried out under the flexible scope of accreditation is made available to the public or upon request by the accredited body. Tests performed both at the laboratory's premises and at external locations are marked with the symbol + in column 2 of the accreditation scope. Type of activity / parameter / characteristic tested |
PN-EN 16034 | ||
| 110 | Ventilation components | Tightness, pressure test Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. E – Flexible scope of accreditation. The flexibility of the scope covers the elements specified in document DA-10 for the scope of accreditation of testing laboratories. A list of activities carried out under the flexible scope of accreditation is made available to the public or upon request by the accredited body. Type of activity / parameter / characteristic tested |
PN-EN 1507 | PN-EN 12237 | PN-EN 13180 | ||
| 111 | Ventilation components | Strength, stiffness Regulated area: Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions: 96/580/EC, 98/436/EC, 98/437/EC, 99/93/EC, 2000/245/EC; Regulation of the Minister of Infrastructure and Construction of 17 November 2016 on the method of declaring the performance of building products and the manner of marking them with the construction mark. E – Flexible scope of accreditation. The flexibility of the scope covers the elements specified in document DA-10 for the scope of accreditation of testing laboratories. A list of activities carried out under the flexible scope of accreditation is made available to the public or upon request by the accredited body. Type of activity / parameter / characteristic tested |
PN-EN 1507 | PN-EN 12237 | ||
| Test methods | |||||
| 112 | Doors, windows, shutters, blinds, gates and related building hardware | ASSESSMENT OF PERFORMANCE BASED ON TESTS (System 3) Commission decision number 99/93/WE Product(s) Doors, windows, shutters, blinds, gates and related building hardware Harmonised technical specifications EN 14351-1:2006+A2:2016 „O” „Z”; EN 13241-1:2003+A2:2016 „O” „Z” Regulated area: Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011 laying down harmonised conditions for the marketing of construction products and repealing Council Directive 89/106/EEC (OJ EU L 88 of 4.4.2011, as amended) |
EN 14351-1:2006+A2:2016 „O” „Z” | EN 13241-1:2003+A2:2016 „O” „Z” | ||
| 113 | Finishing of internal and external walls and ceilings | ASSESSMENT OF PERFORMANCE BASED ON TESTS (System 3) Commission decision number 98/437/WE Product(s) Finishing of internal and external walls and ceilings Harmonised technical specifications EN 14509:2013 „O” „Z” Regulated area: Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011 laying down harmonised conditions for the marketing of construction products and repealing Council Directive 89/106/EEC (OJ EU L 88 of 4.4.2011, as amended) |
EN 14509:2013 „O” „Z” | ||
| 114 | Curtain walls | ASSESSMENT OF PERFORMANCE BASED ON TESTS (System 3) Commission decision number 96/580/ WE Product(s) Curtain walls Harmonised technical specifications EN 13830:2003 „O” „Z” Regulated area: Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011 laying down harmonised conditions for the marketing of construction products and repealing Council Directive 89/106/EEC (OJ EU L 88 of 4.4.2011, as amended) |
EN 13830:2003 „O” „Z” | ||
| 115 | Flat glass, profiled glass and glass elements | ASSESSMENT OF PERFORMANCE BASED ON TESTS (System 3) Commission decision number 2000/245/ WE Product(s) Flat glass, profiled glass and glass elements Harmonised technical specifications EN 12150-2:2004 „O”; EN 14449:2005+AC:2005 „O”; EN 14449:2005 „O”; EN 1863-2:2004 „O”; EN 1279-5:2018 „O” Regulated area: Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011 laying down harmonised conditions for the marketing of construction products and repealing Council Directive 89/106/EEC (OJ EU L 88 of 4.4.2011, as amended) |
EN 12150-2:2004 „O” | EN 14449:2005+AC:2005 „O” | EN 14449:2005 „O” | EN 1863-2:2004 „O” | EN 1279-5:2018 „O” | ||
| 116 | Roofing, rooflights, roof windows and additional parts | ASSESSMENT OF PERFORMANCE BASED ON TESTS (System 3) Commission decision number 98/436/ WE Product(s) Roofing, rooflights, roof windows and additional parts Harmonised technical specifications EN 1873:2005 „O”; EN 14351-1:2006+A2:2016 „O” Regulated area: Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011 laying down harmonised conditions for the marketing of construction products and repealing Council Directive 89/106/EEC (OJ EU L 88 of 4.4.2011, as amended) |
EN 1873:2005 „O” | EN 14351-1:2006+A2:2016 „O” | ||
| 117 | ASSESSMENT OF PERFORMANCE / ASSESMENT OF PERFORMANCE Essential characteristic Fire resistance Technical specification EN 1364-1; EN 1364-3; EN 1364-4; EN 1366-3; EN 1366-4; EN 1366-7; EN 1634-1; EN 1634-2; EN 1634-3; EN 1365-2 Regulated area: Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011 laying down harmonised conditions for the marketing of construction products and repealing Council Directive 89/106/EEC (OJ EU L 88 of 4.4.2011, as amended). The laboratory meets the requirements of Regulation (EU) No 305/2011 of 9 March 2011 for the activities provided for a testing laboratory (Annex V, point 2, subpoint 3 of Regulation (EU) No 305/2011) in the above scope. |
EN 1364-1 | EN 1364-3 | EN 1364-4 | EN 1366-3 | EN 1366-4 | EN 1366-7 | EN 1634-1 | EN 1634-2 | EN 1634-3 | EN 1365-2 | |||
| 118 | ASSESSMENT OF PERFORMANCE / ASSESMENT OF PERFORMANCE Essential characteristic Resistance to external fire Technical specification TS 1187 Regulated area: Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011 laying down harmonised conditions for the marketing of construction products and repealing Council Directive 89/106/EEC (OJ EU L 88 of 4.4.2011, as amended). The laboratory meets the requirements of Regulation (EU) No 305/2011 of 9 March 2011 for the activities provided for a testing laboratory (Annex V, point 2, subpoint 3 of Regulation (EU) No 305/2011) in the above scope. |
TS 1187 | |||
Reference standards (201)
DIN 18095-2:1991-03
DIN 4102-12:1998
DIN 4102-18:1991-03
DIN 4102-2:1977
DIN 4102-5:1977
EAD 210005-00-0505
EN 12150-2:2004 „O”
EN 1279-5:2018 „O”
EN 13241-1:2003+A2:2016 „O” „Z”
EN 1364-1
EN 1364-3
EN 1364-4
EN 1365-2
EN 1366-3
EN 1366-4
EN 1366-7
EN 13830:2003 „O” „Z”
EN 14351-1:2006+A2:2016 „O”
EN 14351-1:2006+A2:2016 „O” „Z”
EN 14449:2005 „O”
EN 14449:2005+AC:2005 „O”
EN 14509:2013 „O” „Z”
EN 1634-1
EN 1634-2
EN 1634-3
EN 17020-2:2022 *
EN 17020-3:2022 *
EN 17020-5:2023 *
EN 170201:2022 *
EN 1863-2:2004 „O”
EN 1873:2005 „O”
ISO 834-1:1999
NB-CPD/SG06/11/0084
NB-CPR/15/639
NT FIRE 017, 3rd edition, approved in 09-2023
PKN-CEN/TS 1187:2014-03 “N”
PN-83/N-03010
PN-B 03434:1999
PN-EN 10131:2008 cl. 6 *
PN-EN 1026 „N”
PN-EN 1026:2001
PN-EN 1027 „N”
PN-EN 1027:2001
PN-EN 1191
PN-EN 1192 *
PN-EN 1192:2001 *
PN-EN 12046-2
PN-EN 12101-1:2007 Annex C
PN-EN 12101-1:2007, Annex D
PN-EN 12150-2:2006 „N”
PN-EN 12152 „N’’
PN-EN 12153 „N’’
PN-EN 12154 „N’’
PN-EN 12155 „N’’
PN-EN 12179 „N’’
PN-EN 12211 „N”
PN-EN 12211:2001
PN-EN 12217
PN-EN 12237
PN-EN 12400:2004 *
PN-EN 12424 „N”
PN-EN 12425 „N”
PN-EN 12426 „N”
PN-EN 12427 „N”
PN-EN 12428:2013-06 „N”
PN-EN 12444 „N”
PN-EN 12445:2002 cl. 5 „N”
PN-EN 12445:2002 cl. 4.1.1.4 „N”
PN-EN 12445:2002 cl. 7.3 „N”
PN-EN 12489 „N”
PN-EN 12600:2004
PN-EN 12605:2002 cl. 5.4.1 „N”
PN-EN 12605:2002 cl. 5.1 „N”
PN-EN 12605:2002 cl. 5.2 „N”
PN-EN 12605:2002 cl. 5.3.2 „N”
PN-EN 12605:2002 cl. 5.4.3 „N”
PN-EN 12605:2002 cl. 5.1.1 „N”
PN-EN 12605:2002 cl. 5.1.2 „N”
PN-EN 12605:2002 cl. 5.3.1 „N”
PN-EN 12605:2002 cl. 5.4.2 „N”
PN-EN 1279-5:2018 „N”
PN-EN 13049
PN-EN 13116 „N’’
PN-EN 13180
PN-EN 13241:2003+A2:2016 „N”
PN-EN 13501-2:2023-09 *
PN-EN 1363-1
PN-EN 1363-1 *
PN-EN 1363-1:2012
PN-EN 1363-1:2020-07
PN-EN 1363-2
PN-EN 1363-2 *
PN-EN 1363-2:2001
PN-EN 1364-1 „N" *
PN-EN 1364-3:2014-03 „N"
PN-EN 1364-4:2014-04 „N"
PN-EN 1365-2:2014-12 „N"
PN-EN 1366-3+A1:2025-04 „N
PN-EN 1366-3:2010 „N"
PN-EN 1366-3:2022-05 „N"
PN-EN 1366-4 + A1:2011 „N"
PN-EN 1366-4:2021- 07 „N"
PN-EN 1366-7:2006 „N"
PN-EN 13830+A1:2020-11 cl. 4.14, 5.14
PN-EN 13830:2005 cl. 4.7 „N”
PN-EN 13947:2008 „N”
PN-EN 14239:2004 *„O”
PN-EN 14351-1+A2:2016 „N”
PN-EN 14351-1+A2:2016-1 cl. 4.10
PN-EN 14351-1+A2:2016-10 „N”
PN-EN 14351-2:2018-12
PN-EN 14351-2:2018-12 cl. 4.10, 5.10
PN-EN 14351-2:2018-12 cl. 5.10
PN-EN 14351-2:2018-12 cl. 5.3
PN-EN 14351-2:2018-12 cl. 5.4
PN-EN 14351-2:2018-12 cl. 5.8.2
PN-EN 14351-2:2018-12 cl. 5.9
PN-EN 14449:2008 „N”
PN-EN 14509:2013 „N”
PN-EN 14509:2013-12 cl. 5.2.4.2, C2 „N"
PN-EN 1505:2001 *
PN-EN 1507
PN-EN 15254-4:2019-01
PN-EN 15254-5 *
PN-EN 15269-10:2011
PN-EN 15269-11 *
PN-EN 15269-2 *
PN-EN 15269-20:2021-02
PN-EN 15269-3 *
PN-EN 15269-5+A1:2016-11
PN-EN 15269-7:2010
PN-EN 15659:2009
PN-EN 15659:2019-12
PN-EN 16005:2013-04 cl. 4.7.2.1
PN-EN 16005:2013-04 cl. 4.3.2
PN-EN 16005:2013-04 cl. 4.4.2; 4.4.3; 4.4.4
PN-EN 16005:2013-04 cl. 4.5
PN-EN 16005:2013-04 cl. 4.6.11
PN-EN 16005:2013-04 cl. 4.6.1; 4.6.2; 4.6.3; 4.6.5; 4.6.6
PN-EN 16005:2013-04 cl. 4.6.7
PN-EN 16005:2013-04 cl. 4.7.2.2
PN-EN 16005:2013-04 cl. 4.7.2.3
PN-EN 16005:2013-04 cl. 5.8
PN-EN 16034
PN-EN 16034:2014
PN-EN 1627:2021-11 *
PN-EN 1628:2021-11
PN-EN 1629:2021-11
PN-EN 1630:2021-11
PN-EN 1634-1 „N" *
PN-EN 1634-2 *
PN-EN 1634-3
PN-EN 1634-3 „N"
PN-EN 1634-3:2006
PN-EN 1634-3:2006/AC:2006
PN-EN 16361+A1:2016-08
PN-EN 16361+A1:2016-08 cl. 4.10
PN-EN 16361+A1:2016-08 cl. 4.12
PN-EN 16361+A1:2016-08 cl. 4.14.3
PN-EN 16361+A1:2016-08 cl. 4.3
PN-EN 16361+A1:2016-08 cl. 4.4
PN-EN 16361+A1:2016-08 cl. 4.6
PN-EN 16361+A1:2016-08 cl. 4.7
PN-EN 16361+A1:2016-08 cl. 4.8
PN-EN 17020-4:2021-10*
PN-EN 170204:2021-10 *
PN-EN 1863-2:2004 „N”
PN-EN 1873+A1:2016-03
PN-EN 1873:2006 „N”
PN-EN 673:2011 „N”
PN-EN 947
PN-EN 948 „N"
PN-EN 949
PN-EN 950
PN-EN 951:2000
PN-EN 952:2000
PN-EN ISO 10077- 2:2017- 10/A1:2025- 06 „N”
PN-EN ISO 10077-1:2007 „N”
PN-EN ISO 10077-1:2017-10 „N”
PN-EN ISO 10077-2:2012
PN-EN ISO 10077-2:2012 „N”
PN-EN ISO 10077-2:2017-10
PN-EN ISO 10077-2:2017-10 „N”
PN-EN ISO 10211:2017-09
PN-EN ISO 10211:2017-09 „N”
PN-EN ISO 12543-5:2011 cl. 4.1.3
PN-EN ISO 12543-5:2022-05 cl. 4.1.3
PN-EN ISO 12631:2017-10
PN-EN ISO 2808:2020-01 Methods 7B.2, 7C
PN-EN ISO 6946:2017-10
PN-EN ISO 6946:2017-10 „N”
PN-ENV 1187:2004+A1:2007 „N”
Certbud procedure S23A-1, issue dated 30.07.2021
Certbud procedure S23H-1a, issue dated 30.07.2021
Certbud procedure S23H-1b, issue dated 30.07.2021
Certbud procedure S25-1 issue 1, dated 10.01.2024
R9-P22-LBiW issue of 09.01.2021
TS 1187
WO-KOT/36/01 issue 3 Table 1 cl. 3 *
WO-KOT/36/01 issue 3 Table 1 cl. 3 *
WO-KOT/36/01 issue 3 Table 1 cl. 4*