🇵🇱 SOLDI sp. z o.o. PL

PCA AB 1571 • Kraków, Poland • 59 methods

EnvironmentElectronics & EMC

SOLDI sp. z o.o. is a laboratory accredited by PCA under number AB 1571 (Kraków, Poland). Its accreditation scope covers 59 test methods in the following areas: Environment, Electronics & EMC. Test objects include: Environment – electromagnetic field in the vicinity of radiocommuni…, Workplace environment - electromagnetic field in the workspace orig…, Workplace environment - electromagnetic field originating from equi…, Workplace environment - electromagnetic field originating from indu…. Most frequently used techniques: Direct measurement method, Gravimetric method, Direct measurement method (simplified).

At a glance

  • Accreditation number: PCA AB 1571
  • Methods in scope: 59
  • Types of test objects: 21
  • Techniques used: 4
  • City: Kraków, Poland
Accreditation number
AB 1571
Accreditation body
PCA
Address
ul. Bieżanowska 22, 30-812 Kraków
City
Kraków, Poland

What this laboratory tests (21)

Analytical techniques used (4)

Laboratory locations

Certificate information

Issue date
25.05.2026
Issue no.
19

Accreditation scope — test methods (59)

No. Test object Methodology / Parameters Technique Reference document
SOLDI Testing Laboratory
1 Workplace environment - electromagnetic field originating from industrial installations and equipment: - arc welding equipment - resistance welding machines - industrial magnetisers and demagnetisers - electrolytic installations - NMR spectrometers - dielectric heating equipment - induction heating equipment - industrial microwave furnaces, heaters and dryers, - equipment for the production and processing of plastics - soldering equipment - electrical discharge machines - resistance and arc furnaces - inverters Electric field strength:
in the frequency range from 10 Hz up to 500 kHz Range 1 V/m – 49 kV/m in the frequency range from 100 kHz up to 3 GHz Range (1,0 – 980) V/m in the frequency range from 80 MHz up to 90 GHz Range (1,0 – 350) V/m
Direct measurement method PN-T-06580-3:2002 Method adapted to the regulated area | Instruction I-05 issue 10 of 02.06.2025, Annex 1
2 Workplace environment - electromagnetic field originating from industrial installations and equipment: - arc welding equipment - resistance welding machines - industrial magnetisers and demagnetisers - electrolytic installations - NMR spectrometers - dielectric heating equipment - induction heating equipment - industrial microwave furnaces, heaters and dryers, - equipment for the production and processing of plastics - soldering equipment - electrical discharge machines - resistance and arc furnaces - inverters Magnetic flux density:
with a frequency of 0 Hz Range 0,3 mT – 1 T in the frequency range from 10 Hz up to 500 kHz Range 0,1 µT – 19 mT
Direct measurement method PN-T-06580-3:2002 Method adapted to the regulated area | Instruction I-05 issue 10 of 02.06.2025, Annex 1
3 Workplace environment - electromagnetic field originating from industrial installations and equipment: - arc welding equipment - resistance welding machines - industrial magnetisers and demagnetisers - electrolytic installations - NMR spectrometers - dielectric heating equipment - induction heating equipment - industrial microwave furnaces, heaters and dryers, - equipment for the production and processing of plastics - soldering equipment - electrical discharge machines - resistance and arc furnaces - inverters Magnetic field strength:
in the frequency range from 300 kHz up to 35 MHz Range (0,010 – 16,0) A/m in the frequency range from 20 MHz up to 1 GHz Range (0,010 – 10,0) A/m
Direct measurement method PN-T-06580-3:2002 Method adapted to the regulated area | Instruction I-05 issue 10 of 02.06.2025, Annex 1
4 Workplace environment - electromagnetic field originating from industrial installations and equipment: - arc welding equipment - resistance welding machines - industrial magnetisers and demagnetisers - electrolytic installations - NMR spectrometers - dielectric heating equipment - induction heating equipment - industrial microwave furnaces, heaters and dryers, - equipment for the production and processing of plastics - soldering equipment - electrical discharge machines - resistance and arc furnaces - inverters Magnetic field strength:
in the frequency range: from 1 GHz up to 3 GHz (calculated)
PN-T-06580-3:2002 Method adapted to the regulated area | Instruction I-05 issue 10 of 02.06.2025, Annex 1
5 Workplace environment - electromagnetic field originating from radiocommunication and anti-theft systems: - handheld radiotelephones, short range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) - anti-theft and electronic article surveillance systems Electric field strength:
in the frequency range from 10 Hz up to 500 kHz Range 1 V/m – 49 kV/m in the frequency range from 100 kHz up to 3 GHz Range (1,0 – 980) V/m in the frequency range from 80 MHz up to 90 GHz Range (1,0 – 350) V/m
Direct measurement method PN-T-06580-3:2002 Method adapted to the regulated area | Instruction I-05 issue 10 of 02.06.2025, Annex 2
6 Workplace environment - electromagnetic field originating from radiocommunication and anti-theft systems: - handheld radiotelephones, short range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) - anti-theft and electronic article surveillance systems Magnetic flux density:
with a frequency of 0 Hz Range 0,3 mT – 1 T in the frequency range from 10 Hz up to 500 kHz Range 0,1 µT – 19 mT
Direct measurement method PN-T-06580-3:2002 Method adapted to the regulated area | Instruction I-05 issue 10 of 02.06.2025, Annex 2
7 Workplace environment - electromagnetic field originating from radiocommunication and anti-theft systems: - handheld radiotelephones, short range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) - anti-theft and electronic article surveillance systems Magnetic field strength:
in the frequency range from 300 kHz up to 35 MHz Range (0,010 – 16,0) A/m in the frequency range from 20 MHz up to 1 GHz Range (0,010 – 10,0) A/m
Direct measurement method PN-T-06580-3:2002 Method adapted to the regulated area | Instruction I-05 issue 10 of 02.06.2025, Annex 2
8 Workplace environment - electromagnetic field originating from radiocommunication and anti-theft systems: - handheld radiotelephones, short range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) - anti-theft and electronic article surveillance systems Magnetic field strength:
in the frequency range: from 1 GHz up to 3 GHz (calculated)
PN-T-06580-3:2002 Method adapted to the regulated area | Instruction I-05 issue 10 of 02.06.2025, Annex 2
9 Workplace environment - electromagnetic field originating from equipment used in medical technology: - surgical diathermy - physiotherapeutic diathermy - magnetic resonance scanners Electric field strength:
in the frequency range from 10 Hz up to 500 kHz Range 1 V/m – 49 kV/m in the frequency range from 100 kHz up to 3 GHz Range (1,0 – 980) V/m in the frequency range from 80 MHz up to 90 GHz Range (1,0 – 350) V/m
Direct measurement method PN-T-06580-3:2002 Method adapted to the regulated area | Instruction I-05 issue 10 of 02.06.2025, Annex 3
10 Workplace environment - electromagnetic field originating from equipment used in medical technology: - surgical diathermy - physiotherapeutic diathermy - magnetic resonance scanners Magnetic flux density:
with a frequency of 0 Hz Range 0,3 mT – 1 T in the frequency range from 10 Hz up to 500 kHz Range 0,1 µT – 19 mT
Direct measurement method PN-T-06580-3:2002 Method adapted to the regulated area | Instruction I-05 issue 10 of 02.06.2025, Annex 3
11 Workplace environment - electromagnetic field originating from equipment used in medical technology: - surgical diathermy - physiotherapeutic diathermy - magnetic resonance scanners Magnetic field strength:
in the frequency range from 100 kHz up to 1 GHz Range (0,010 – 16,0) A/m in the frequency range from 300 kHz up to 35 MHz Range (0,010 – 16,0) A/m in the frequency range from 20 MHz up to 1 GHz Range (0,010 – 10,0) A/m
Direct measurement method PN-T-06580-3:2002 Method adapted to the regulated area | Instruction I-05 issue 10 of 02.06.2025, Annex 3
12 Workplace environment - electromagnetic field originating from equipment used in medical technology: - surgical diathermy - physiotherapeutic diathermy - magnetic resonance scanners Magnetic field strength:
in the frequency range: from 0,8 GHz up to 90 GHz from 1 GHz up to 3 GHz (calculated)
PN-T-06580-3:2002 Method adapted to the regulated area | Instruction I-05 issue 10 of 02.06.2025, Annex 3
13 Workplace environment - electromagnetic field in the workspace from magnetotherapy devices Magnetic field strength:
in the frequency range from 10 Hz up to 1 kHz (calculated)
Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (Journal of Laws of 2018, item 331).
Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 151–180
14 Workplace environment - electromagnetic field in the workspace from magnetotherapy devices Magnetic flux density:
in the frequency range from 10 Hz up to 1 kHz Range 1,25 µT – 19 mT
Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (Journal of Laws of 2018, item 331).
Direct measurement method (simplified) Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 151–180
15 Workplace environment - electromagnetic field in the workspace from power systems and AC electrical supply installations in the power industry Electric field strength:
in the frequency range from 45 Hz to 55 Hz Range 1 V/m – 49,0 kV/m
Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (Journal of Laws of 2018, item 331).
Direct measurement method Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 91–150
16 Workplace environment - electromagnetic field in the workspace from power systems and AC electrical supply installations in the power industry Magnetic field strength:
in the frequency range from 45 Hz to 55 Hz (calculated)
Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (Journal of Laws of 2018, item 331).
Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 91–150
17 Workplace environment - electromagnetic field in the workspace from power systems and AC electrical supply installations in the power industry Magnetic flux density:
in the frequency range from 45 Hz up to 55 kHz Range 1,25 µT – 19 mT
Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (Journal of Laws of 2018, item 331).
Direct measurement method Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 91–150
18 Workplace environment - electromagnetic field in the workspace from transmitting devices of radiocommunication systems (mobile telephony base stations) Electric field strength:
in the frequency range from 100 kHz up to 3,6 GHz Range (0,5 – 1000) V/m in the frequency range from 3 GHz up to 90 GHz Range (0,5 – 350) V/m
Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (Journal of Laws of 2018, item 331).
Direct measurement method Principles and Methods of Assessing the Working Environment 2017, No. 2 (92), pp. 89–131
19 Workplace environment - electromagnetic field in the workspace from transmitting devices of radiocommunication systems (mobile telephony base stations) Magnetic field strength:
in the frequency range from 80 MHz up to 1 GHz Range (0,010 – 10) A/m
Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (Journal of Laws of 2018, item 331).
Direct measurement method Principles and Methods of Assessing the Working Environment 2017, No. 2 (92), pp. 89–131
20 Workplace environment - electromagnetic field in the workspace from transmitting devices of radiocommunication systems (mobile telephony base stations) Magnetic field strength:
in the frequency range from 0,8 GHz up to 90 GHz (calculated)
Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (Journal of Laws of 2018, item 331).
Principles and Methods of Assessing the Working Environment 2017, No. 2 (92), pp. 89–131
21 Workplace environment - electromagnetic field in the workspace originating from radiocommunication transmitting equipment (broadcasting and radiocommunication transmitting systems - radio, television, etc.) Electric field strength:
in the frequency range from 100 kHz up to 3 GHz Range (0,5 – 1000) V/m in the frequency range from 3 GHz up to 90 GHz Range (0,5 – 248) V/m
Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (Journal of Laws of 2018, item 331).
Direct measurement method Principles and Methods of Assessing the Working Environment 2017, No. 2 (92), pp. 89–131
22 Workplace environment - electromagnetic field in the workspace originating from radiocommunication transmitting equipment (broadcasting and radiocommunication transmitting systems - radio, television, etc.) Magnetic field strength:
in the frequency range from 300 kHz up to 35 MHz Range (0,010 – 16) A/m in the frequency range from 20 MHz up to 1 GHz Range (0,010 – 10) A/m
Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (Journal of Laws of 2018, item 331).
Direct measurement method Principles and Methods of Assessing the Working Environment 2017, No. 2 (92), pp. 89–131
23 Workplace environment - electromagnetic field in the workspace originating from radiocommunication transmitting equipment (broadcasting and radiocommunication transmitting systems - radio, television, etc.) Magnetic flux density:
in the frequency range from 100 kHz up to 300 kHz Range (0,1 – 41,0) µT
Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (Journal of Laws of 2018, item 331).
Direct measurement method Principles and Methods of Assessing the Working Environment 2017, No. 2 (92), pp. 89–131
24 Workplace environment - electromagnetic field in the workspace originating from radiocommunication transmitting equipment (broadcasting and radiocommunication transmitting systems - radio, television, etc.) Magnetic field strength:
in the frequency range from 100 kHz up to 300 kHz from 0,8 GHz up to 90 GHz (calculated)
Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (Journal of Laws of 2018, item 331).
Principles and Methods of Assessing the Working Environment 2017, No. 2 (92), pp. 89–131
25 Environment – electromagnetic field in the vicinity of electric power substations and power lines Electric field strength:
in the frequency range 50 Hz Range 1 V/m – 49 kV/m
Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Direct measurement method Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630)
26 Environment – electromagnetic field in the vicinity of electric power substations and power lines Magnetic flux density:
in the frequency range 50 Hz Range 0,1 µT – 19 mT
Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Direct measurement method Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630)
27 Environment – electromagnetic field in the vicinity of electric power substations and power lines Magnetic field strength:
in the frequency range 50 Hz (calculated)
Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630)
28 Environment – electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) Electric field strength:
in the frequency range from 100 kHz up to 3,6 GHz Range (0,5 – 1000) V/m in the frequency range from 3,0 GHz up to 90 GHz Range (0,5 – 350) V/m
Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Direct measurement method Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630)
29 Environment – electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) Magnetic flux density:
in the frequency range from 100 kHz up to 300 kHz Range (0,1 – 41,0) µT
Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Direct measurement method Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630)
30 Environment – electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) Magnetic field strength:
in the frequency range from 300 kHz up to 10 MHz Range (0,010 – 16) A/m
Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Direct measurement method Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630)
31 Environment – electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) Magnetic field strength:
in the frequency range from 100 kHz up to 300 kHz (calculated)
Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630)
32 Environment – electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) Magnetic field strength:
in the frequency range from 10 MHz up to 90 GHz (calculated)
Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Clause 3 of the Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630)
33 Workplace environment – noise A-weighted equivalent sound level Maximum A-weighted sound level
Range (26 – 136) dB C-weighted peak sound pressure level Range (28 – 136) dB
Direct measurement method PN-N-01307:1994 | PN-EN ISO 9612:2011 excluding the method covering strategy 2 - cl. 10 and strategy 3 – cl. 11
34 Workplace environment – noise Noise exposure level referred to:
an 8-hour daily working time the average weekly working time (calculated)
PN-N-01307:1994 | PN-EN ISO 9612:2011 excluding the method covering strategy 2 - cl. 10 and strategy 3 – cl. 11
35 Workplace environment – hand-arm vibration Frequency-weighted r.m.s. vibration acceleration
Range (0,5 – 60) m/s2
Direct measurement method PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11
36 Workplace environment – hand-arm vibration Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the vector sum of the r.m.s. frequency-corrected vibration accelerations determined for three directional components (ahwx, ahwy, ahwz), Exposure lasting 30 minutes or less, expressed as the vector sum of the r.m.s. frequency-weighted vibration accelerations determined for three directional components (ahwx, ahwy, ahwz) (calculated) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11
37 Workplace environment – whole-body vibration Frequency-weighted r.m.s. vibration acceleration
Range (0,03 – 35,5) m/s²
Direct measurement method PN-EN 14253+A1:2011
38 Workplace environment – whole-body vibration Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the r.m.s. frequency-corrected vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz), Exposure lasting 30 minutes or less, expressed as the r.m.s. frequency-weighted vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz) (calculated) PN-EN 14253+A1:2011
39 Workplace environment – hot microclimate Air temperature
Range (10 – 60) °C Natural wet bulb temperature Range (10 – 60) °C Black globe temperature Range (10 – 60) °C
Direct measurement method PN-EN ISO 7243:2018-01
40 Workplace environment – hot microclimate WBGT index, WBGTeff index (calculated) PN-EN ISO 7243:2018-01
41 Workplace environment – cold microclimate Air temperature
Range (-30 – 10) °C Black globe temperature Range (-30 – 10) °C Air humidity Range (20 – 90) % Air velocity Range (0,15 – 10) m/s
Direct measurement method PN-EN ISO 11079:2008
42 Workplace environment – cold microclimate IREQmin index, IREQneutral index, twc index (calculated) PN-EN ISO 11079:2008
43 Workplace environment – moderate microclimate Air temperature
Range (10 – 30) °C Black globe temperature Range (10 – 40) °C Air humidity Range (20 – 90) % Air velocity Range (0,15 – 1) m/s
Direct measurement method PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04
44 Workplace environment – moderate microclimate PMV index, PPD index (calculated) PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04
45 General environment – noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level
Range (26 – 136) dB
Direct measurement method Annex 7 to the Regulation of the Minister of the Environment of 07.09.2021 (consolidated text Journal of Laws of 2023 item 1706) excluding cl. F
46 General environment – noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Annex 7 to the Regulation of the Minister of the Environment of 07.09.2021 (consolidated text Journal of Laws of 2023 item 1706) excluding cl. F
47 Workplace environment – indoor electric lighting Illuminance
Range (0,5 – 9800) lx
Direct measurement method PN-83/E-04040.03
48 Workplace environment – indoor electric lighting Illuminance uniformity (calculated) PN-83/E-04040.03
49 Workplace environment – outdoor electric lighting Illuminance
Range (0,5 – 9800) lx
Direct measurement method PN-83/E-04040.03
50 Workplace environment – outdoor electric lighting Ratio of minimum to maximum illuminance (calculated) PN-83/E-04040.03
51 Workplace environment – outdoor electric lighting Illuminance uniformity (calculated) PN-83/E-04040.03
52 Workplace environment – emergency lighting Illuminance
Range (0,5 – 500) lx
Direct measurement method PN-83/E-04040.03 | PN-EN 1838:2025-05 excluding cl. 5.1.3 – 5.1.9, 5.2.3 – 5.2.7, 5.3.4 – 5.3.8, 6, 7.2
53 Workplace environment – emergency lighting Ratio of minimum to maximum illuminance (calculated) PN-83/E-04040.03 | PN-EN 1838:2025-05 excluding cl. 5.1.3 – 5.1.9, 5.2.3 – 5.2.7, 5.3.4 – 5.3.8, 6, 7.2
54 Workplace environment – energy expenditure Air temperature
Range (0 – 60) °C Air flow Range (10 – 60) dm3/min
Direct measurement method PB-02 issue 6 of 11.02.2025
55 Workplace environment – energy expenditure Energy expenditure (calculated) PB-02 issue 6 of 11.02.2025
56 Workplace environment – air Sampling for assessment of occupational exposure to: − dust agents
inhalable fraction respirable fraction − inorganic substances, including respirable fraction − organic substances, including inhalable fraction − metals and their compounds, including inhalable fraction respirable fraction
Personal dosimetry method PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004
57 Workplace environment – air Exposure index (calculated) PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004
58 Workplace environment – air Concentration of harmful dust agents - inhalable fraction:
Petroleum bitumen Apatites and phosphorites Portland cement Titanium dioxide Natural graphite Synthetic graphite Kaolin Amorphous and synthetic silica Wood dusts Flour dusts Dusts not classified according to toxicity Organic dusts of animal and plant origin, excluding wood and flour dusts Calcium sulfate (VI) (gypsum) Carbon black Coal (hard, brown) Calcium magnesium carbonate (dolomite) Silicon carbide, non-fibrous Range (0,12 – 17,0) mg/m3
Gravimetric method PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08
59 Workplace environment – air Concentration of harmful dust agents - respirable fraction:
Apatites and phosphorites Portland cement Natural graphite Amorphous and synthetic silica Organic dusts of animal and plant origin, excluding wood and flour dusts Coal (hard, brown) Range (0,12 – 15,4) mg/m3
Gravimetric method PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08

Reference standards (29)

Instruction I-05 issue 10 of 02.06.2025, Annex 1
Instruction I-05 issue 10 of 02.06.2025, Annex 2
Instruction I-05 issue 10 of 02.06.2025, Annex 3
PB-02 issue 6 of 11.02.2025
PN-83/E-04040.03
PN-EN 14253+A1:2011
PN-EN 1838:2025-05 excluding cl. 5.1.3 – 5.1.9, 5.2.3 – 5.2.7, 5.3.4 – 5.3.8, 6, 7.2
PN-EN ISO 11079:2008
PN-EN ISO 5349-1:2004
PN-EN ISO 5349-2:2004
PN-EN ISO 5349-2:2004/A1:2015-11
PN-EN ISO 7243:2018-01
PN-EN ISO 7730:2006
PN-EN ISO 7730:2006/Ap2:2016-04
PN-EN ISO 9612:2011 excluding the method covering strategy 2 - cl. 10 and strategy 3 – cl. 11
PN-N-01307:1994
PN-T-06580-3:2002 Method adapted to the regulated area
PN-Z-04008-7:2002
PN-Z-04008-7:2002/Az1:2004
PN-Z-04507:2022-05
PN-Z-04507:2022-05/Ap1:2022-08
PN-Z-04508:2022-05
PN-Z-04508:2022-05/Ap1:2022-08
Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 151–180
Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 91–150
Principles and Methods of Assessing the Working Environment 2017, No. 2 (92), pp. 89–131
Clause 3 of the Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630)
Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630)
Annex 7 to the Regulation of the Minister of the Environment of 07.09.2021 (consolidated text Journal of Laws of 2023 item 1706) excluding cl. F

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/PL/AB%201571