🇵🇱 J.S. HAMILTON POLAND Sp. z o.o. PL

PCA AB 1552 • Siemianowice Śląskie, Poland • 182 methods

ConstructionMaterials & polymers

J.S. HAMILTON POLAND Sp. z o.o. is a laboratory accredited by PCA under number AB 1552 (Siemianowice Śląskie, Poland). Its accreditation scope covers 182 test methods in the following areas: Construction, Materials & polymers. Test objects include: Toys, Electrical machines and equipment, including mining equipment, Audio/video, information technology and telecommunications equipment, Electrical equipment for potentially explosive atmospheres. Intrins…. Most frequently used techniques: Direct method, Force loading method, Flame method.

At a glance

  • Accreditation number: PCA AB 1552
  • Methods in scope: 182
  • Types of test objects: 60
  • Techniques used: 32
  • City: Siemianowice Śląskie, Poland
Accreditation number
AB 1552
Accreditation body
PCA
Address
ul. Chwaszczyńska 180, 81-571 Gdynia, LABORATORIUM BADAWCZE, ul. Wyzwolenia 14, 41-103 Siemianowice Śląskie
City
Siemianowice Śląskie, Poland

What this laboratory tests (60)

Analytical techniques used (32)

Laboratory locations

Certificate information

Issue date
01.09.2026
Issue no.
20

Accreditation scope — test methods (182)

No. Test object Methodology / Parameters Technique Reference document
Testing Laboratory
1 Electrical equipment for use in potentially explosive atmospheres, examples: - rotating electrical machines, - electrical transformers, - switches and switchgear, - fixed and portable luminaires, - battery and accumulator lamps, - fuses, - sensors, measuring transducers and control and measuring equipment, - communication and signalling equipment, - DC mains power supplies, - automation, control and transmission equipment Linear geometric quantities
Range 0,01 mm - 30 m
Direct method PN-EN 60079-0:2013-03 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012 | IEC 60079-0:2012 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017
2 Electrical equipment for use in potentially explosive atmospheres, examples: - rotating electrical machines, - electrical transformers, - switches and switchgear, - fixed and portable luminaires, - battery and accumulator lamps, - fuses, - sensors, measuring transducers and control and measuring equipment, - communication and signalling equipment, - DC mains power supplies, - automation, control and transmission equipment Impact strength PN-EN 60079-0:2013-03 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012 | IEC 60079-0:2012 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017
3 Electrical equipment for use in potentially explosive atmospheres, examples: - rotating electrical machines, - electrical transformers, - switches and switchgear, - fixed and portable luminaires, - battery and accumulator lamps, - fuses, - sensors, measuring transducers and control and measuring equipment, - communication and signalling equipment, - DC mains power supplies, - automation, control and transmission equipment Free-fall drop resistance PN-EN 60079-0:2013-03 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012 | IEC 60079-0:2012 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017
4 Electrical equipment for use in potentially explosive atmospheres, examples: - rotating electrical machines, - electrical transformers, - switches and switchgear, - fixed and portable luminaires, - battery and accumulator lamps, - fuses, - sensors, measuring transducers and control and measuring equipment, - communication and signalling equipment, - DC mains power supplies, - automation, control and transmission equipment Temperature measurement
Range 0°C – 450°C
PN-EN 60079-0:2013-03 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012 | IEC 60079-0:2012 | PN-EN IEC 60079-0:2018-09 | PN-EN IEC 60079-0:2018-09/AC:2020-04 | EN IEC 60079-0:2018 | IEC 60079-0:2017
5 Electrical equipment for use in potentially explosive atmospheres, examples: - rotating electrical machines, - electrical transformers, - switches and switchgear, - fixed and portable luminaires, - battery and accumulator lamps, - fuses, - sensors, measuring transducers and control and measuring equipment, - communication and signalling equipment, - DC mains power supplies, - automation, control and transmission equipment Thermal resistance to heat
Range up to 180°C Chamber dimensions: 1000 mm x 1020 mm x 1413 mm
PN-EN 60079-0:2013-03 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012 | IEC 60079-0:2012 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017 | PN-EN 60068-2-78:2013-11
6 Electrical equipment for use in potentially explosive atmospheres, examples: - rotating electrical machines, - electrical transformers, - switches and switchgear, - fixed and portable luminaires, - battery and accumulator lamps, - fuses, - sensors, measuring transducers and control and measuring equipment, - communication and signalling equipment, - DC mains power supplies, - automation, control and transmission equipment Thermal resistance to cold
Range up to -50°C Chamber dimensions: 1000 mm x 1020 mm x 1413 mm
PN-EN 60079-0:2013-03 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012 | IEC 60079-0:2012 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017 | PN-EN 60068-2-1:2009
7 Electrical equipment for use in potentially explosive atmospheres, examples: - rotating electrical machines, - electrical transformers, - switches and switchgear, - fixed and portable luminaires, - battery and accumulator lamps, - fuses, - sensors, measuring transducers and control and measuring equipment, - communication and signalling equipment, - DC mains power supplies, - automation, control and transmission equipment Resistance to sudden temperature change PN-EN 60079-0:2013-03 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012 | IEC 60079-0:2012 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017
8 Electrical equipment for use in potentially explosive atmospheres, examples: - rotating electrical machines, - electrical transformers, - switches and switchgear, - fixed and portable luminaires, - battery and accumulator lamps, - fuses, - sensors, measuring transducers and control and measuring equipment, - communication and signalling equipment, - DC mains power supplies, - automation, control and transmission equipment Measurement of the surface resistance of non-metallic enclosure parts, R = 1 x 104 - 1 x 1012 Ω PN-EN 60079-0:2013-03 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012 | IEC 60079-0:2012 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017 | PN-EN 60079-32-2:2015-08
9 Electrical equipment for use in potentially explosive atmospheres, examples: - rotating electrical machines, - electrical transformers, - switches and switchgear, - fixed and portable luminaires, - battery and accumulator lamps, - fuses, - sensors, measuring transducers and control and measuring equipment, - communication and signalling equipment, - DC mains power supplies, - automation, control and transmission equipment IP degree of protection
Range from IP 1X, 2X, 3X, 4X, 5X, 6X, X1, X2, X3, X4, X5, X6, X7, X8
PN-EN 60079-0:2013-03 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012 | IEC 60079-0:2012 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017
10 Electrical equipment for use in potentially explosive atmospheres, examples: - rotating electrical machines, - electrical transformers, - switches and switchgear, - fixed and portable luminaires, - battery and accumulator lamps, - fuses, - sensors, measuring transducers and control and measuring equipment, - communication and signalling equipment, - DC mains power supplies, - automation, control and transmission equipment Sealing and fixing of cable glands – direct testing by applying:
forces (pull-out test) in the range from 1N up to 10kN torque (mechanical strength test) in the range from 2Nm up to 400 Nm
PN-EN 60079-0:2013-03 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012 | IEC 60079-0:2012 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017 | PN-G-50003:2003
11 Electrical apparatus for potentially explosive atmospheres - Flameproof enclosures „d” Linear geometric quantities
Range 0,01 mm - 30 m
Direct method PN-EN 60079-1:2014-12 cl. 5,6,7,8,9,10,11,12,13 | EN 60079-1:2014 cl. 5,6,7,8,9,10,11,12,13 | IEC 60079-1:2014 cl. 5,6,7,8,9,10,11,12,13
12 Electrical apparatus for potentially explosive atmospheres - Flameproof enclosures „d” Explosion pressure, reference (base) pressure
Range up to 3 MPa
Method: measurement of the maximum explosion pressure PN-EN 60079-1:2014-12 | EN 60079-1:2014 | IEC 60079-1:2014
13 Electrical apparatus for potentially explosive atmospheres - Flameproof enclosures „d” Resistance of the enclosure to pressure
Range up to 3 MPa
Method: static pressure loading PN-EN 60079-1:2014-12 | EN 60079-1:2014 | IEC 60079-1:2014
14 Electrical apparatus for potentially explosive atmospheres - Flameproof enclosures „d” Resistance of the enclosure to pressure
Range up to 3 MPa
Method: dynamic pressure loading PN-EN 60079-1:2014-12 | EN 60079-1:2014 | IEC 60079-1:2014
15 Electrical apparatus for potentially explosive atmospheres - Flameproof enclosures „d” Protection against explosion transmission PN-EN 60079-1:2014-12 | EN 60079-1:2014 | IEC 60079-1:2014
16 Electrical apparatus for potentially explosive atmospheres - Flameproof enclosures „d” Tightness and strength of flameproof cable glands – direct testing by:
pressure action (leak test) in the range from 100 Pa up to 3 MPa application of torque (mechanical strength test) in the range from 2 Nm up to 400 Nm
PN-EN 60079-1:2014-12 | EN 60079-1:2014 | IEC 60079-1:2014
17 Electrical apparatus for explosive atmospheres - Pressurized enclosures „p” Linear geometric dimensions Direct method PN-EN 60079-2:2015-02 | PN-EN 60079-2:2015-02/AC1:2015-11 | EN 60079-2:2014 | IEC 60079-2:2014
18 Electrical apparatus for explosive atmospheres - Pressurized enclosures „p” Resistance of the enclosure to pressure
Range up to 3 MPa
Static pressure loading method PN-EN 60079-2:2015-02 | PN-EN 60079-2:2015-02/AC1:2015-11 | EN 60079-2:2014 | IEC 60079-2:2014
19 Electrical apparatus for explosive atmospheres – Increased safety ”e” Linear geometric quantities
Range 0,01 mm - 30 m
Direct method PN-EN 60079-7:2010 | PN-EN 60079-7:2016-02 | PN-EN 60079-7:2016-02/A1:2018-03 | EN 60079-7:2015 | IEC 60079-7:2015
20 Electrical apparatus for explosive atmospheres – Increased safety ”e” Dielectric strength of the insulation
alternating voltage 0,5 kV - 40 kV
PN-EN 60079-7:2010 | PN-EN 60079-7:2016-02 | PN-EN 60079-7:2016-02/A1:2018-03 | PN-EN 60060-2:2011 | EN 60079-7:2015 | IEC 60079-7:2015
21 Electrical apparatus for explosive atmospheres – Increased safety ”e” Impact strength PN-EN 60079-7:2010 | PN-EN 60079-7:2016-02 | PN-EN 60079-7:2016-02/A1:2018-03 | EN 60079-7:2015 | IEC 60079-7:2015
22 Electrical apparatus for explosive atmospheres – Increased safety ”e” Free-fall drop resistance PN-EN 60079-7:2010 | PN-EN 60079-7:2016-02 | PN-EN 60079-7:2016-02/A1:2018-03 | EN 60079-7:2015 | IEC 60079-7:2015
23 Electrical equipment for potentially explosive atmospheres. Intrinsic safety type of protection ”i” Linear geometric quantities
Range 0,01 mm - 30 m
Direct method PN-EN 60079-11:2012 | EN 60079-11:2012 | IEC 60079-11:2011 | IEC 60079-11:2023
24 Electrical equipment for potentially explosive atmospheres. Intrinsic safety type of protection ”i” Dielectric strength of the insulation
alternating voltage 0,5 kV - 40 kV
PN-EN 60079-11:2012 | PN-EN 60060-2:2011 | EN 60079-11:2012 | IEC 60079-11:2011 | IEC 60079-11:2023
25 Electrical equipment for potentially explosive atmospheres. Intrinsic safety type of protection ”i” Insulation distances, Direct measurement PN-EN 60079-11:2012 | EN 60079-11:2012 | IEC 60079-11:2011 | IEC 60079-11:2023
26 Electrical equipment for potentially explosive atmospheres. Intrinsic safety type of protection ”i” Capacity of cells and batteries, Short-circuit resistance of cells and batteries PN-EN 60079-11:2012 | EN 60079-11:2012 | IEC 60079-11:2011 | IEC 60079-11:2023
27 Electrical equipment for potentially explosive atmospheres. Intrinsic safety type of protection ”i” Testing of transformers PN-EN 60079-11:2012 | EN 60079-11:2012 | IEC 60079-11:2011 | IEC 60079-11:2023
28 Electrical equipment for potentially explosive atmospheres. Intrinsic safety type of protection ”i” Spark-initiated ignition test PN-EN 60079-11:2012 | EN 60079-11:2012 | IEC 60079-11:2011 | IEC 60079-11:2023
29 Electrical equipment for potentially explosive atmospheres. Intrinsic safety type of protection ”i” Temperature measurement
Range 0°C – 450°C
PN-EN 60079-11:2012 | EN 60079-11:2012 | IEC 60079-11:2011 | IEC 60079-11:2023
30 Electrical equipment for potentially explosive atmospheres. Intrinsic safety type of protection ”i” Cable or wire pull-out test
forces in the range 1N - 10kN
PN-EN 60079-11:2012 | EN 60079-11:2012 | IEC 60079-11:2011 | IEC 60079-11:2023
31 Electrical equipment for potentially explosive atmospheres. Intrinsic safety type of protection ”i” Water immersion test of fuses requiring sealing PN-EN 60079-11:2012 | EN 60079-11:2012 | IEC 60079-11:2011 | IEC 60079-11:2023
32 Electrical equipment for potentially explosive atmospheres. Intrinsic safety type of protection ”i” Measurement of the energy stored by piezoelectric elements PN-EN 60079-11:2012 | EN 60079-11:2012 | IEC 60079-11:2011 | IEC 60079-11:2023
33 Electrical equipment for potentially explosive atmospheres. Intrinsic safety type of protection ”i” Testing of encapsulation compounds and barriers by applying a force from 1N to 500N PN-EN 60079-11:2012 | EN 60079-11:2012 | IEC 60079-11:2011 | IEC 60079-11:2023
34 Electrical apparatus for explosive atmospheres – Type of protection ”n” Linear geometric dimensions Direct method PN-EN 60079-15:2010 | EN 60079-15:2010 | IEC 60079-15:2010 | PN-EN IEC 60079-15:2019-06 | EN IEC 60079-15:2019 | IEC 60079-15:2017
35 Electrical apparatus for explosive atmospheres – Type of protection ”n” Thermal resistance to heat
Range up to 180°C Chamber dimensions: 1000 mm x 1020 mm x 1413 mm
PN-EN 60079-15:2010 | EN 60079-15:2010 | IEC 60079-15:2010 | PN-EN IEC 60079-15:2019-06 | EN IEC 60079-15:2019 | IEC 60079-15:2017
36 Electrical apparatus for explosive atmospheres – Type of protection ”n” Free-fall drop resistance PN-EN 60079-15:2010 | EN 60079-15:2010 | IEC 60079-15:2010
37 Electrical apparatus for explosive atmospheres – Type of protection ”n” Dielectric strength of the insulation
Range alternating voltage 0,5 kV - 40 kV
PN-EN 60079-15:2010 | EN 60079-15:2010 | IEC 60079-15:2010 | PN-EN IEC 60079-15:2019-06 | EN IEC 60079-15:2019 | IEC 60079-15:2017
38 Electrical apparatus for potentially explosive atmospheres – Equipment protected by encapsulation ”m” Thermal tests, temperatures and temperature rises
Range 0°C – 450°C
PN-EN 60079-18:2015-06 | PN-EN 60079-18:2015-06/A1:2018-02 | EN 60079-18:2015 | IEC 60079-18:2014
39 Electrical apparatus for potentially explosive atmospheres – Equipment protected by encapsulation ”m” Thermal resistance to heat
Range up to +180°C Chamber dimensions: 1000 mm x 1020 mm x 1413 mm
PN-EN 60079-18:2015-06 | PN-EN 60079-18:2015-06/A1:2018-02 | EN 60079-18:2015 | IEC 60079-18:2014
40 Electrical apparatus for potentially explosive atmospheres – Equipment protected by encapsulation ”m” Thermal resistance to cold
Range up to -50°C Chamber dimensions: 1000 mm x 1020 mm x 1413 mm
PN-EN 60079-18:2015-06 | PN-EN 60079-18:2015-06/A1:2018-02 | EN 60079-18:2015 | IEC 60079-18:2014
41 Electrical apparatus for potentially explosive atmospheres – Equipment protected by encapsulation ”m” Dielectric strength of the insulation
Range alternating voltage 0,5 kV - 40 kV
PN-EN 60079-18:2015-06 | PN-EN 60079-18:2015-06/A1:2018-02 | EN 60079-18:2015 | IEC 60079-18:2014
42 Electrical apparatus for potentially explosive atmospheres – Equipment protected by encapsulation ”m” Resistance of the enclosure to pressure
Range up to 3 MPa
Static pressure loading method PN-EN 60079-18:2015-06 | PN-EN 60079-18:2015-06/A1:2018-02 | EN 60079-18:2015 | IEC 60079-18:2014
43 Electrical apparatus for potentially explosive atmospheres – Equipment protected by encapsulation ”m” Water absorption by the sealing compound – change of mass in the range from 0,02g to 500g PN-EN 60079-18:2015-06 | PN-EN 60079-18:2015-06/A1:2018-02 | EN 60079-18:2015 | IEC 60079-18:2014
44 Electrical apparatus for potentially explosive atmospheres – Equipment protected by encapsulation ”m” Cable or wire pull-out test – forces in the range 1N-10kN PN-EN 60079-18:2015-06 | PN-EN 60079-18:2015-06/A1:2018-02 | EN 60079-18:2015 | IEC 60079-18:2014
45 Electrical apparatus for potentially explosive atmospheres – Equipment protected by encapsulation ”m” Water immersion test of built-in protective devices requiring sealing PN-EN 60079-18:2015-06 | PN-EN 60079-18:2015-06/A1:2018-02 | EN 60079-18:2015 | IEC 60079-18:2014
46 Electrical apparatus for potentially explosive atmospheres – Intrinsically safe systems Linear geometric dimensions Direct method PN-EN 60079-25:2011 | PN-EN IEC 60079-25:2023-02 | EN 60079-25:2010 | IEC 60079-25:2010 | EN IEC 60079-25:2022 | IEC 60079-25:2020
47 Electrical apparatus for potentially explosive atmospheres – Intrinsically safe systems Insulation distances, Direct measurement PN-EN 60079-25:2011 | PN-EN IEC 60079-25:2023-02 | EN 60079-25:2010 | IEC 60079-25:2010 | EN IEC 60079-25:2022 | IEC 60079-25:2020
48 Electrical apparatus for potentially explosive atmospheres – Intrinsically safe systems Dielectric strength of the insulation
Range alternating voltage 0,5 kV - 40 kV
PN-EN 60079-25:2011 | PN-EN IEC 60079-25:2023-02 | EN 60079-25:2010 | IEC 60079-25:2010 | EN IEC 60079-25:2022 | IEC 60079-25:2020
49 Electrical apparatus for potentially explosive atmospheres – Intrinsically safe systems Capacity of cells and batteries, Short-circuit resistance of cells and batteries PN-EN 60079-25:2011 | PN-EN IEC 60079-25:2023-02 | EN 60079-25:2010 | IEC 60079-25:2010 | EN IEC 60079-25:2022 | IEC 60079-25:2020
50 Electrical apparatus for potentially explosive atmospheres – Intrinsically safe systems Testing of transformers PN-EN 60079-25:2011 | PN-EN IEC 60079-25:2023-02 | EN 60079-25:2010 | IEC 60079-25:2010 | EN IEC 60079-25:2022 | IEC 60079-25:2020
51 Electrical apparatus for explosive atmospheres - Equipment with equipment protection level (EPL) Ga Impact strength
Range Impact energy up to 20 J
PN-EN 60079-26:2015-04 | EN 60079-26:2015 | IEC 60079-26:2014 | IEC 60079-26:2021 | PN-EN 60079-26:2024-09 | EN IEC 60079-26:2024
52 Electrical apparatus for explosive atmospheres - Equipment with equipment protection level (EPL) Ga Thermal tests, temperatures and temperature rises
Range 0°C – 450°C
PN-EN 60079-26:2015-04 | EN 60079-26:2015 | IEC 60079-26:2014 | IEC 60079-26:2021 | PN-EN 60079-26:2024-09 | EN IEC 60079-26:2024
53 Electrical equipment in explosive atmospheres using optical radiation, protection – type of protection „op is” Optical power measurement up to 1 W
band (190 - 20000) nm
PN-EN 60079-28:2015-12 | IEC 60079-28 edition 2.0 2015-05
54 Electrical apparatus for explosive atmospheres - Protection of equipment against dust ignition by enclosure „t” IP degree of protection
Range from IP 1X, 2X, 3X, 4X, 5X, 6X, X1, X2, X3, X4, X5, X6, X7, X8
PN-EN 60079-31:2014-10 | EN 60079-31:2014 | IEC 60079-31:2013 | IEC 60079-31:2022 | PN-EN 60079-31:2024-08 | EN IEC 60079-31:2024
55 Electrical apparatus for explosive atmospheres - Protection of equipment against dust ignition by enclosure „t” Resistance of the enclosure to pressure
Range up to 3 MPa
Method: static pressure loading PN-EN 60079-31:2014-10 | EN 60079-31:2014 | IEC 60079-31:2013 | IEC 60079-31:2022 | PN-EN 60079-31:2024-08 | EN IEC 60079-31:2024
56 Electrical apparatus for explosive atmospheres - Protection of equipment against dust ignition by enclosure „t” Thermal tests, temperatures and temperature rises
Range 0°C – 450°C
PN-EN 60079-31:2014-10 | EN 60079-31:2014 | IEC 60079-31:2013 | IEC 60079-31:2022 | PN-EN 60079-31:2024-08 | EN IEC 60079-31:2024
57 Electrical apparatus for explosive atmospheres - Protection of equipment against dust ignition by enclosure „t” Impact strength PN-EN 60079-31:2014-10 | EN 60079-31:2014 | IEC 60079-31:2013 | IEC 60079-31:2022 | PN-EN 60079-31:2024-08 | EN IEC 60079-31:2024
58 Machinery and equipment. Degrees of protection provided by enclosures (IP code) IP degree of protection
Range from IP 1X, 2X, 3X, 4X, 5X, 6X, X1, X2, X3, X4, X5, X6, X7, X8
PN-EN 60529:2003 | PN-EN 60529:2003/A2:2014-07 | EN 60529:1991+A1:2000 | EN 60529:1991/A2:2013 | IEC 60529:2001 | IEC 60529:1989/AMD2:2013 | PN-EN IEC 60034-5:2021-01 | EN IEC 60034-5:2020 | IEC 60034-5:2020
59 Machinery and equipment. Degrees of protection provided by enclosures (IP code) Degree of protection IP: 1X, 2X, 3X, 4X, 5kX, 6kX, X1, X2, X3, X4, X5, X6, X7, X8 ISO 20653:2023 (E)
60 Enclosures for electrical equipment IK degree of protection
Range (IK01 - IK10), IK 50J
PN-EN 50102:2001 | PN-EN 50102:2001/AC:2011 | PN-EN 60068-2-75:2015-01 (test Ehc) | PN-EN 62262:2003 | PN-EN 62262:2003/A1:2022-06
61 Enclosures for electrical equipment Impact resistance - spring hammer test PN-EN 60068-2-75:2015-01 (test Ehb)
62 Non-electrical equipment for use in potentially explosive atmospheres Linear geometric dimensions
Range 0,01 mm - 30 m
Direct method PN-EN ISO 80079-36:2016-07 | EN ISO 80079-36:2016 | ISO 80079-36:2016
63 Non-electrical equipment for use in potentially explosive atmospheres Impact strength PN-EN ISO 80079-36:2016-07 | EN ISO 80079-36:2016 | ISO 80079-36:2016
64 Non-electrical equipment for use in potentially explosive atmospheres Free-fall drop resistance PN-EN ISO 80079-36:2016-07 | EN ISO 80079-36:2016 | ISO 80079-36:2016
65 Non-electrical equipment for use in potentially explosive atmospheres Temperature measurement
Range 0°C – 450°C
PN-EN ISO 80079-36:2016-07 | EN ISO 80079-36:2016 | ISO 80079-36:2016
66 Non-electrical equipment for use in potentially explosive atmospheres Resistance to thermal shock PN-EN ISO 80079-36:2016-07 | EN ISO 80079-36:2016 | ISO 80079-36:2016
67 Non-electrical equipment for use in potentially explosive atmospheres Surface resistance RS
Range R = 1 x 104 - 1 x 1012 Ω
PN-EN ISO 80079-36:2016-07 | EN ISO 80079-36:2016 | ISO 80079-36:2016
68 Non-electrical equipment for use in potentially explosive atmospheres Thermal resistance, hot
Range up to 180°C Chamber dimensions: 1000 mm x 1020 mm x 1413 mm
PN-EN ISO 80079-36:2016-07 | PN-EN ISO 80079-36:2016-07/AC:2020-05 | EN ISO 80079-36:2016 | ISO 80079-36:2016
69 Non-electrical equipment for use in potentially explosive atmospheres Thermal resistance to cold
Range up to -50°C Chamber dimensions: 1000 mm x 1020 mm x 1413 mm
PN-EN ISO 80079-36:2016-07 | EN ISO 80079-36:2016 | ISO 80079-36:2016
70 Non-electrical equipment for use in potentially explosive atmospheres Linear geometric dimensions
Range 0,01 mm - 30 m
Direct method PN-EN ISO 80079-36:2016-07 | EN ISO 80079-36:2016 | ISO 80079-36:2016
71 Flat solid materials used to prevent electrostatic charge accumulation Surface resistance RS of non-metallic materials
Range R = 1 x 104 - 1 x 1012 Ω
PN-EN 61340-2-3:2016-11
72 Flat solid materials used to prevent electrostatic charge accumulation Volume resistance RV of non-metallic materials
Range R = 1 x 104 - 1 x 1012 Ω
PN-EN 61340-2-3:2016-11
73 Flat solid materials used to prevent electrostatic charge accumulation Point-to-point resistance RP of non-metallic materials
Range R = 1 x 104 - 1 x 1012 Ω
PN-EN 61340-2-3:2016-11
74 Non-metallic materials Burning time
Flame application time 10 s (according to PN-EN ISO/IEC 80079-38:2017-02 point 6.2)
Flame method PN-EN ISO 340:2022-12 | PN-EN ISO/IEC 80079-38:2017-02
75 Materials used in vehicles Burning time, Flame spread distance, Burning rate PN-ISO 3795:1996 | FMVSS 302 | UN Regulation No. 118 – Annex 6 | DIN 75200:1980-09 | TL 1010:2008-01 | PSA D45 1333:2020-01 | GB 8410:2006 | PTL 8501 (Porsche) | D45 1333 (Renault) | STD 5031.19 (Volvo) | JIS D 1201 (J) / cl. 6
76 Conveyor belts Burning time Flame method PN-EN ISO 340:2022-12 | PN-93-C-05013
77 Conveyor belts Surface resistance, Resistance value from 1 x 103 Ω to 1 x 1012 Ω PN-EN ISO 284:2013-06
78 Conveyor belts Tensile strength elongation at break elongation at a specified load force (1-1000) kN displacement (0-98) mm PN-EN ISO 283:2023-10
79 Conveyor belts Strength of the joint force (1-1000) kN PN-EN ISO 1120:2013-03
80 Conveyor belts Friction on the drum, Maximum drum temperature, Presence of flame and/or glow PN-EN ISO 20238:2019-05 excluding methods: A.1.2, A.2.2, B.1.2, B.2.2
81 Non-metallic materials, plastics including: electrical cables and wires and optical fibre cables Fire hazard (flammability tests): Test methods with a nominal test flame: 1 kW, 50 W PN-EN 60695-11-2:2017-11 | PN-EN 60332-1-2:2010 | PN-EN 60332-1-2:2010/A1:2016-02 | PN-EN 60332-1-2:2010/A11:2017-02 | PN-EN 60332-1-2:2010/A12:2021-05 | PN-EN 60332-2-2:2010 | PN-EN 60695-11-10:2014-02 | PN-EN 60695-11-10:2014-02/AC:2017-08 | PN-EN ISO 9773:2003 | PN-EN ISO 9773:2003/A1:2005 | UL 94 cl. 7, 8, 11 (HB, V-0, V-1, V2, VTM-0, VTM-1, VTM-2)
82 Non-metallic materials, plastics including: electrical cables and wires and optical fibre cables Determination of flammability by the oxygen index method PN-EN ISO 4589-2:2017-06
83 Non-metallic materials, plastics including: electrical cables and wires and optical fibre cables Fire hazard testing (flammability test) with a needle flame PN-EN 60695-11-5:2017-08 | IEC 60695-11-5:2016
84 Non-metallic materials, plastics including: electrical cables and wires and optical fibre cables Fire hazard testing – hot wire test PN-EN 60695-2-10:2013-12 | PN-EN IEC 60695-2-10:2022-07 | PN-EN 60695-2-11:2015-02 | PN-EN IEC 60695-2-11:2022-07 | PN-EN 60695-2-12:2011 | PN-EN 60695-2-12:2011/A1:2014-10 | PN-EN IEC 60695-2-12:2022-06 | PN-EN 60695-2-13:2011 | PN-EN 60695-2-13:2011/A1:2014-10 | PN-EN IEC 60695-2-13:2022-05 | IEC 60695-2-10:2021 | IEC 60695-2-11:2021 | IEC 60695-2-12:2021 | IEC 60695-2-13:2021
85 Non-metallic materials, plastics including: electrical cables and wires and optical fibre cables Fire hazard testing – abnormal heat PN-EN 60695-10-2:2014-10 | IEC 60695-10-2:2014
86 Welded mesh linings for mine working supports Surface condition Visual method PN-G-15050:2018-01
87 Welded mesh linings for mine working supports Geometric dimensions Direct method PN-G-15050:2018-01
88 Welded mesh linings for mine working supports Bending strength of the mesh Verification of the Mg equivalent
Load range up to 1000 kN
Force loading method PN-G-15050:2018-01
89 Welded mesh linings for mine working supports Strength of the bar material
Load range up to 1000 kN
Force loading method PN-G-15050:2018-01
90 Welded mesh linings for mine working supports Weld shear force
Load range up to 1000 kN
Force loading method PN-G-15050:2018-01
91 Metals Tensile strength
force (0 - 1000) kN Elongation (0 - 100 mm)
Force loading method PN-EN ISO 6892-1:2020-05 Method B
92 Metals Flexural strength
force (0 - 1000) kN
Force loading method PN-EN ISO 7438:2021-04
93 Metals Impact energy
Range KV2 ; KU2 Initial hammer energy 300J Test temperature 23±5° C Reduced up to -50°C Impact strength test by the Charpy method
PN-EN ISO 148-1:2017-02
94 Stirrup yokes Linear dimensions
Bending strength -force up to 1000 kN deflection up to 0,1 m Bolt tension force (0 - 1000) kN Elongation (0 - 100) mm Load test of the nut and U-bolt force (0 - 1000) kN Elongation (0 - 100) mm
Direct measurement method; Force loading method with displacement measurement; Force loading method; Force loading method PN-G-15026:2017-04
95 Mining bolts Linear dimensions, straightness
Strength of the pole - tensile - bending - shear Range up to 1000kN Strength of washers and nuts Range up to 1000 kN
Direct measurement method; Force loading method; Force loading method PN-G-15092:1999
96 Electrical machines and equipment, including mining equipment Clearances
Range 0,5 mm - 300 mm
PN-G-50003:2003
97 Electrical machines and equipment, including mining equipment Insulation resistance
Range up to 1 TΩ (at U = 0,5 kV - 2,5 kV)
PN-G-50003:2003 | PN-EN 60204-1:2018-12
98 Electrical machines and equipment, including mining equipment Electric strength of insulation,
alternating voltage 0,5 kV - 40 kV
PN-G-50003:2003 | PN-EN 60204-1:2018-12
99 Electrical machines and equipment, including mining equipment Resistance to damp heat, steady state
Range up to 95°C and up to 98 % RH Chamber dimensions: 1000 mm x 1020 mm x 1413 mm
Method: Cab test PN-G-50003:2003 | PN-EN 60068-2-78:2013-11
100 Electrical machines and equipment, including mining equipment Cold resistance
Range up to -50°C Chamber dimensions: 1000 mm x 1020 mm x 1413 mm
PN-G-50003:2003 | PN-EN 60068-2-1:2009
101 Electrical machines and equipment, including mining equipment Resistance to dry heat
Range up to 180°C Chamber dimensions: 1000 mm x 1020 mm x 1413 mm
PN-G-50003:2003 | PN-EN 60068-2-2:2009
102 Electrical machines and equipment, including mining equipment Resistance to damp heat, cyclic, Chamber dimensions: 1000 mm x 1020 mm x 1413 mm PN-EN 60068-2-30:2008
103 Electrical machines and equipment, including mining equipment Resistance to change of temperature, Test: Na, Nb (up to 4 K/min), Nc. PN-EN 60068-2-14:2009 | PN-EN IEC 60068-2-14:2024-04 | IEC 60068-2-14:2023
104 Electrical machines and equipment, including mining equipment Resistance of products to the harmful effects of high temperature/humidity and cold environments, Test Z/AD: Composite temperature/humidity cyclic test, Chamber dimensions: 950 mm x 950 mm x 1100 mm PN-EN IEC 60068-2-38:2021-12
105 Electrical machines and equipment, including mining equipment Resistance of small electrotechnical components to the harmful effects of damp heat, Test Cy: damp heat, steady state, accelerated test primarily intended for components, Chamber dimensions: 950 mm x 1100 mm x 1475 mm PN-EN 60068-2-67:2004 | PN-EN 60068-2-67:2004/A1:2019-11
106 Electrical machines and equipment, including mining equipment Temperature measurement
Range 0°C – 450°C
PN-G-50003:2003
107 Electrical machines and equipment, including mining equipment IP degree of protection
Range from IP 1X, 2X, 3X, 4X, 5X, 6X, X1, X2, X3, X4, X5, X6, X7, X8
PN-G-50003:2003
108 Electrical machines and equipment, including mining equipment Protection against residual voltages 60 V PN-EN 60204-1:2018-12
109 Electrical machines and equipment, including mining equipment Luminance measurement
Range (0,1-12000) cd/m2 Measurement of luminance uniformity Range (0-100%)
PN-EN ISO 9241-305:2009 cl. 6.6.1; 6.6.3
110 Construction products and materials, builders' hardware, components of machinery and electrical equipment, including mining equipment Resistance to daylight under controlled environmental conditions PN-EN IEC 60068-2-5:2018 | PN-EN ISO 4892-1:2016-06 | PN-EN ISO 4892-2:2013-06 | PN-EN ISO 4892-2:2013-06/A1:2022-01 | PN-EN ISO 16474-1:2014-02 | PN-EN ISO 16474-2:2014-02 | PN-EN ISO 16474-2:2014-02/A1:2023-02 | PV 3929:2018-03 | PV 3930:2017-11 | SAE J2527:2004-02
111 Construction products and materials, builders' hardware, components of machinery and electrical equipment, including mining equipment Resistance to ultraviolet light under controlled environmental conditions PN-EN ISO 4892-3:2016-04 | PN-EN ISO 16474-3:2014-02
112 Construction products and materials, builders' hardware, components of machinery and electrical equipment, including mining equipment Resistance to salt mist, Test Ka PN-EN IEC 60068-2-11:2021-11 | PN-EN 2591-307:2012 excluding 5.4
113 Construction products and materials, builders' hardware, components of machinery and electrical equipment, including mining equipment Resistance to cyclic salt mist, Test Kb PN-EN IEC 60068-2-52:2018-05 Test NSS | VW 75174:2018-10 Test L18.2
114 Construction products and materials, builders' hardware, components of machinery and electrical equipment, including mining equipment Resistance to corrosion in artificial corrosive atmospheres PN-EN ISO 9227:2023-02 Test NSS | ASTM B117-11 | BMW AA-0324:2018-04 excluding the assessment according to standard GS 90010 (cl. 4.0) | PN-EN 1670:2008
115 Construction products and materials, builders' hardware, components of machinery and electrical equipment, including mining equipment Determination of resistance to cyclic corrosion conditions PN-EN ISO 11997-1:2017-10 | VDA-621-415
116 Construction products and materials, builders' hardware, components of machinery and electrical equipment, including mining equipment Assessment of degree of blistering PN-EN ISO 4628-1:2016-03 | PN-EN ISO 4628-2:2016-03
117 Construction products and materials, builders' hardware, components of machinery and electrical equipment, including mining equipment Assessment of degree of rusting PN-EN ISO 4628-1:2016-03 | PN-EN ISO 4628-3:2016-03
118 Construction products and materials, builders' hardware, components of machinery and electrical equipment, including mining equipment Assessment of degree of cracking PN-EN ISO 4628-1:2016-03 | PN-EN ISO 4628-4:2016-03
119 Construction products and materials, builders' hardware, components of machinery and electrical equipment, including mining equipment Assessment of degree of flaking PN-EN ISO 4628-1:2016-03 | PN-EN ISO 4628-5:2023-01
120 Empty enclosures for low-voltage switchgear and controlgear assemblies Durability of marking, Degree of protection against external mechanical impacts (IK code), Degree of protection (IP code), Thermal stability, Dielectric strength, Continuity of the protective circuit, Resistance to corrosion PN-EN 62208:2011 | PN-EN IEC 62208:2024-04 | IEC 62208:2023
121 Low-voltage switchgear and controlgear assemblies Durability of marking, Thermal stability, Resistance to dry heat, Flammability category, Impact strength, Degree of protection (IP code), Clearances and creepage distances, Effective continuity between exposed conductive parts of the assembly and the protective circuit, Power-frequency withstand voltage, Temperature-rise limits, Dielectric strength, Resistance to corrosion PN-EN 61439-1:2011 | PN-EN IEC 61439-1:2021-10 | PN-EN 61439-5:2015-02 | PN-EN IEC 61439-5:2024-04 | IEC 61439-5:2023
122 Rubber and plastics hoses and hose assemblies Linear geometric dimensions
Range up to 150 mm Resistance to test pressure Range up to 2500 bar Resistance to burst pressure Range up to 2500 bar Resistance to leakage pressure Range up to 2500 bar
Measurement method: direct; Method: static pressure loading; Method: static pressure loading PN-EN ISO 4671:2022-09 | PN-EN ISO 1402:2021-10 | PN-G-32010:2012
123 Rubber and plastics hoses and hose assemblies Surface resistance - direct resistance measurement
Range R=1 x 103 - 1 x 1012 Ω
PN-EN ISO 8031:2021-01
124 Rubber and plastics hoses and hose assemblies Flammability
Flame application time 60 s
Flame method PN-EN ISO 8030:2014-09
125 Mining hydraulic drives and controls – plug-in couplings Minimum burst pressure
Range up to 2500 bar Geometric dimensions Range up to 150 mm
Method: static pressure loading; Measurement method: direct PN-G-32000:2011 | PN-EN ISO 1402:2021-10
126 Plastic products Electrostatic charging
Range up to 200 nC
Direct measurement method PN-EN 60079-32-2:2015-08 | PN-EN 80079-36:2016-07 Annex D
127 Toys Size of toys or detached components Method: small parts cylinder test PN-EN 71-1:2015-01 | PN-EN 71-1+A1:2018-08 | EN 71-1:2014+A1:2018
128 Toys Torsional strength Method: torsion test PN-EN 71-1:2015-01 | PN-EN 71-1+A1:2018-08 | EN 71-1:2014+A1:2018
129 Toys Tensile strength Method: tensile test PN-EN 71-1:2015-01 | PN-EN 71-1+A1:2018-08 | EN 71-1:2014+A1:2018
130 Toys Drop strength Method: free fall test PN-EN 71-1:2015-01 | PN-EN 71-1+A1:2018-08 | EN 71-1:2014+A1:2018
131 Toys Impact resistance Method: impact test PN-EN 71-1:2015-01 | PN-EN 71-1+A1:2018-08 | EN 71-1:2014+A1:2018
132 Toys Compressive strength Method: compression test PN-EN 71-1:2015-01 | PN-EN 71-1+A1:2018-08 | EN 71-1:2014+A1:2018
133 Toys Accessibility of a part or component of a toy Method: probes PN-EN 71-1:2015-01 | PN-EN 71-1+A1:2018-08 | EN 71-1:2014+A1:2018
134 Toys Sharpness of edges Method: test tape PN-EN 71-1:2015-01 | PN-EN 71-1+A1:2018-08 | EN 71-1:2014+A1:2018
135 Toys Sharpness of points Method: test with a test head PN-EN 71-1:2015-01 | PN-EN 71-1+A1:2018-08 | EN 71-1:2014+A1:2018
136 Toys Flexibility of wires Method: bend test PN-EN 71-1:2015-01 | PN-EN 71-1+A1:2018-08 | EN 71-1:2014+A1:2018
137 Toys Leakage of liquid-filled toys Method: needle test PN-EN 71-1:2015-01 | PN-EN 71-1+A1:2018-08 | EN 71-1:2014+A1:2018
138 Toys Geometric shape of certain toys Method: shape templates PN-EN 71-1:2015-01 | PN-EN 71-1+A1:2018-08 | EN 71-1:2014+A1:2018
139 Toys Durability of mouth-actuated toys Method: durability test PN-EN 71-1:2015-01 | PN-EN 71-1+A1:2018-08 | EN 71-1:2014+A1:2018
140 Toys Stability Method: stability test PN-EN 71-1:2015-01 | PN-EN 71-1+A1:2018-08 | EN 71-1:2014+A1:2018
141 Toys Static strength Method: static mass loading PN-EN 71-1:2015-01 | PN-EN 71-1+A1:2018-08 | EN 71-1:2014+A1:2018
142 Toys Thickness of plastic film Method: direct measurement PN-EN 71-1:2015-01 | PN-EN 71-1+A1:2018-08 | EN 71-1:2014+A1:2018
143 Toys Flammability:
flaming combustion time maximum length of burnt material above the point of application flame spread rate
Method: flammability test PN-EN 71-2+A1:2014-06 | PN-EN 71-2:2021-05 | EN 71-2:2020
144 Electrical and electronic equipment and its metal, polymer, ceramic, textile, paper and electronic components, materials used in the manufacture of electrical and electronic equipment Element content
Cd (50 – 150) mg/kg Pb (300 – 1500) mg/kg Hg (300 – 1500) mg/kg Br total (50 – 1500) mg/kg Cr total (300 – 1500) mg/kg
Energy-dispersive X-ray fluorescence spectrometry (ED-XRF) PN-EN 62321-3-1:2014-08
145 Luminaires Examination of marking, Internal and external wiring, Provision for earthing, Protection against electric shock, Resistance to dust, solid objects (IP1X-IP6X) and moisture (IPX1-IPX4, IPX5-IPX7), Insulation resistance and electric strength, touch current and protective conductor current, Creepage distances and clearances, Endurance test and thermal test, Screw terminals, Screwless terminals and electrical connections, Construction, Resistance to heat and fire PN-EN IEC 60598-1:2021-07 (excluding 4.13.6, 4.20, 4.24) | PN-EN IEC 60598-1:2021-07/A11:2022-12
146 Fixed general purpose luminaires Features and properties according to the product standard for luminaires:
PN-EN IEC 60598-1 2021-07 PN-EN IEC 60598-1 2021-07/A11:2022-12
PN-IEC 598-2-1+A1:1994 | PN-IEC 598-2-1+A1:1994/Ap1:2000
147 Recessed luminaires Features and properties according to the product standard for luminaires:
PN-EN IEC 60598-1 2021-07 PN-EN IEC 60598-1 2021-07/A11:2022-12
PN-EN 60598-2-2:2012 | PN-EN IEC 60598-2-2:2024-06
148 Road and street lighting luminaires Features and properties according to the product standard for luminaires:
PN-EN IEC 60598-1 2021-07 PN-EN IEC 60598-1 2021-07/A11:2022-12
PN-EN 60598-2-3:2006 | PN-EN 60598-2-3:2006/A1:2012
149 Portable general purpose luminaires Features and properties according to the product standard for luminaires:
PN-EN IEC 60598-1 2021-07 PN-EN IEC 60598-1 2021-07/A11:2022-12
PN-EN 60598-2-4:2018-06
150 Luminaires with built-in transformers or convertors Features and properties according to the product standard for luminaires:
PN-EN IEC 60598-1 2021-07 PN-EN IEC 60598-1 2021-07/A11:2022-12
PN-EN 60598-2-6:2000
151 Portable garden luminaires Features and properties according to the product standard for luminaires:
PN-EN IEC 60598-1 2021-07 PN-EN IEC 60598-1 2021-07/A11:2022-12
PN-EN 60598-2-7:2000
152 Portable luminaires for children Features and properties according to the product standard for luminaires:
PN-EN IEC 60598-1 2021-07 PN-EN IEC 60598-1 2021-07/A11:2022-12
PN-EN 60598-2-10:2005 | PN-EN 60598-2-10:2005/AC:2006
153 Ground recessed luminaires Features and properties according to the product standard for luminaires:
PN-EN IEC 60598-1 2021-07 PN-EN IEC 60598-1 2021-07/A11:2022-12
PN-EN 60598-2-13:2007 | PN-EN 60598-2-13:2007/A1:2012 | PN-EN 60598-2-13:2007/A2:2017-02 | PN-EN 60598-2-13:2007/A11:2021-09
154 Luminaires for emergency lighting Features and properties according to the product standard for luminaires:
PN-EN IEC 60598-1 2021-07 PN-EN IEC 60598-1 2021-07/A11:2022-12
PN-EN 60598-2-22:2015-01 | PN-EN 60598-2-22:2015-01/A1:2020-08 (excluding 22.17, 22.19) | PN-EN IEC 60598-2-22:2022-11
155 Luminaires with limited surface temperatures Features and properties according to the product standard for luminaires:
PN-EN IEC 60598-1 2021-07 PN-EN IEC 60598-1 2021-07/A11:2022-12
PN-EN 60598-2-24:2014-02
156 Electrical appliances for household and similar use Protection against access to live parts, Power input and current, Heating, Leakage current and electric strength at operating temperature, Transient overvoltages, Moisture resistance (IPX1-IPX3, IPX4-IPX7), Leakage current and electric strength, Overload protection of transformers and associated circuits, Stability and mechanical hazards, Clearances, creepage distances and solid insulation thickness, Mechanical strength, Resistance to heat and glow PN-EN 60335-1:2012 cl. 8, 10, 11, 13, 14, 15, 16, 17, 20, 21, 29, 30 | PN-EN 60335-1:2012/A11:2014-10 | PN-EN 60335-1:2012/A13:2017-11 | PN-EN 60335-1:2012/A1:2019-10 | PN-EN 60335-1:2012/A2:2019-11 | PN-EN 60335-1:2012/A14:2020-05 | PN-EN 60335-1:2012/A15:2022-01 | PN-EN IEC 60335-1:2024-04 | IEC 60335-1:2020 | PN-EN IEC 60335-1:2024-04/A11:2024-10 cl. 8, 10, 11, 13, 14, 15, 16, 17, 20, 21, 29, 30
157 Vacuum cleaners and water-suction cleaning equipment Features and properties according to the product standard for household and similar electrical appliances:
PN-EN 60335-1 2012 points. 8, 10, 11, 13, 14, 15, 16, 17, 20, 29 PN-EN 60335-1 2012/A11:2014-10 PN-EN 60335-1 2012/A13:2017-11 PN-EN 60335-1 2012/A1:2019-10 PN-EN 60335-1 2012/A2:2019-11 PN-EN 60335-1 2012/A14:2020-05 PN-EN 60335-1 2012/A15:2022-01 PN-EN IEC 60335-1 2024-04 IEC 60335-1 2020 PN-EN IEC 60335-1 2024-04/A11:2024-10 points 8, 10, 11, 13, 14, 15, 16, 17, 20, 21, 29, 30
PN-EN 60335-2-2:2010 | PN-EN 60335-2-2:2010/A11:2013-05 | PN-EN IEC 60335-2-2:2024-02 | PN-EN IEC 60335-2-2:2024-02/A11:2024-04
158 Electric irons Features and properties according to the product standard for household and similar electrical appliances:
PN-EN 60335-1 2012 points. 8, 10, 11, 13, 14, 15, 16, 17, 20, 29 PN-EN 60335-1 2012/A11:2014-10 PN-EN 60335-1 2012/A13:2017-11 PN-EN 60335-1 2012/A1:2019-10 PN-EN 60335-1 2012/A2:2019-11 PN-EN 60335-1 2012/A14:2020-05 PN-EN 60335-1 2012/A15:2022-01 PN-EN IEC 60335-1 2024-04 IEC 60335-1 2020 PN-EN IEC 60335-1 2024-04/A11:2024-10 points 8, 10, 11, 13, 14, 15, 16, 17, 20, 21, 29, 30
PN-EN 60335-2-3:2016-03
159 Shavers, hair clippers and similar appliances Features and properties according to the product standard for household and similar electrical appliances:
PN-EN 60335-1 2012 points. 8, 10, 11, 13, 14, 15, 16, 17, 20, 29 PN-EN 60335-1 2012/A11:2014-10 PN-EN 60335-1 2012/A13:2017-11 PN-EN 60335-1 2012/A1:2019-10 PN-EN 60335-1 2012/A2:2019-11 PN-EN 60335-1 2012/A14:2020-05 PN-EN 60335-1 2012/A15:2022-01 PN-EN IEC 60335-1 2024-04 IEC 60335-1 2020 PN-EN IEC 60335-1 2024-04/A11:2024-10 points 8, 10, 11, 13, 14, 15, 16, 17, 20, 21, 29, 30
PN-EN 60335-2-8:2015 | PN-EN 60335-2-8:2015/A1:2016-04 | PN-EN 60335-2-8:2015/A2:2023-02 | PN-EN 60335-2-8:2015/A11:2023-01 | PN-EN 60335-2-8:2015/A12:2023-04
160 Kitchen machines PN-EN 60335-1
PN-EN 60335-1 2012/A15:2022-01
PN-EN 60335-2-14:2009 | PN-EN 60335-2-14:2009/A1:2009 | PN-EN 60335-2-14:2009/A11:2012 | PN-EN 60335-2-14:2009/A12:2016-03 | PN-EN IEC 60335-2-14:2024-03 | PN-EN IEC 60335-2-14:2024-03/A1:2024-06
161 Skin and hair care appliances PN-EN 60335-1
PN-EN 60335-1 2012/A15:2022-01
PN-EN 60335-2-23:2006 +A1:2008 | PN-EN 60335-2-23:2006/A2:2015 | PN-EN 60335-2-23:2006/A11:2010E | PN-EN IEC 60335-2-23:2023-10 | PN-EN IEC 60335-2-23:2023-10/A1:2023-10 | PN-EN IEC 60335-2-23:2023-10/A11:2024-02
162 Battery chargers PN-EN 60335-1
PN-EN 60335-1 2012/A15:2022-01
PN-EN 60335-2-29:2005 +A2:2015-03 | PN-EN 60335-2-29:2005/A11:2018-11 | PN-EN IEC 60335-2-29:2022-05 | PN-EN IEC 60335-2-29:2022-05/A1:2022-06 | PN-EN IEC 60335-2-29:2022-05/A11:2024-09
163 Room heaters PN-EN 60335-1
PN-EN 60335-1 2012/A15:2022-01
PN-EN 60335-2-30:2010 | PN-EN 60335-2-30:2010/A11:2012 | PN-EN 60335-2-30:2010/A1:2020-09 | PN-EN 60335-2-30:2010/A12:2021-02 | PN-EN 60335-2-30:2010/A2:2023-04 | PN-EN 60335-2-30:2010/A13:2023-04
164 Surface-cleaning appliances using liquids or steam PN-EN 60335-1
PN-EN 60335-1 2012/A15:2022-01
PN-EN 60335-2-54:2009 | PN-EN 60335-2-54:2009/A1:2015-11 | PN-EN 60335-2-54:2009/A11:2013-05 | PN-EN 60335-2-54:2010/A2:2022-06 | PN-EN 60335-2-54:2010/A12:2022-05
165 Audio/video, information technology and telecommunications equipment Exposure test to xenon arc light PN-EN IEC 62368-1:2020-11 | PN-EN IEC 62368-1:2024-06 | IEC 62368-1:2023 | PN-EN 60950-1:2007 | PN-EN 62368-1:2015-03 | PN-EN 62368-1:2015-03/A11:2017-09
166 Audio/video, information technology and telecommunications equipment Durability of marking test PN-EN IEC 62368-1:2020-11 | PN-EN IEC 62368-1:2024-06 | IEC 62368-1:2023 | PN-EN 60950-1:2007 | PN-EN 62368-1:2015-03 | PN-EN 62368-1:2015-03/A11:2017-09
167 Audio/video, information technology and telecommunications equipment Electric strength test, Voltage range 0,5 kV - 40 kV PN-EN IEC 62368-1:2020-11 | PN-EN IEC 62368-1:2024-06 | IEC 62368-1:2023 | PN-EN 60950-1:2007 | PN-EN 62368-1:2015-03 | PN-EN 62368-1:2015-03/A11:2017-09
168 Audio/video, information technology and telecommunications equipment Measurement of insulation clearances PN-EN IEC 62368-1:2020-11 | PN-EN IEC 62368-1:2024-06 | IEC 62368-1:2023 | PN-EN 60950-1:2007 | PN-EN 62368-1:2015-03 | PN-EN 62368-1:2015-03/A11:2017-09
169 Audio/video, information technology and telecommunications equipment Testing of the degree of protection of the enclosure (IP3X, IP4X, IPX1-IPX8) PN-EN IEC 62368-1:2020-11 | PN-EN IEC 62368-1:2024-06 | IEC 62368-1:2023 | PN-EN 60950-1:2007 | PN-EN 62368-1:2015-03 | PN-EN 62368-1:2015-03/A11:2017-09
170 Audio/video, information technology and telecommunications equipment Fire hazard testing (flammability test) with a needle flame PN-EN IEC 62368-1:2020-11 | PN-EN IEC 62368-1:2024-06 | IEC 62368-1:2023 | PN-EN 60950-1:2007 | PN-EN 62368-1:2015-03 | PN-EN 62368-1:2015-03/A11:2017-09
171 Audio/video, information technology and telecommunications equipment Flammability classification of materials PN-EN IEC 62368-1:2020-11 | PN-EN IEC 62368-1:2024-06 | IEC 62368-1:2023 | PN-EN 60950-1:2007 | PN-EN 62368-1:2015-03 | PN-EN 62368-1:2015-03/A11:2017-09
172 Audio/video, information technology and telecommunications equipment Strength under the action of a force PN-EN IEC 62368-1:2020-11 | PN-EN IEC 62368-1:2024-06 | IEC 62368-1:2023 | PN-EN 60950-1:2007 | PN-EN 62368-1:2015-03 | PN-EN 62368-1:2015-03/A11:2017-09
173 Audio/video, information technology and telecommunications equipment Impact test on the enclosure PN-EN IEC 62368-1:2020-11 | PN-EN IEC 62368-1:2024-06 | IEC 62368-1:2023 | PN-EN 60950-1:2007 | PN-EN 62368-1:2015-03 | PN-EN 62368-1:2015-03/A11:2017-09
174 Audio/video, information technology and telecommunications equipment Drop test PN-EN IEC 62368-1:2020-11 | PN-EN IEC 62368-1:2024-06 | IEC 62368-1:2023 | PN-EN 60950-1:2007 | PN-EN 62368-1:2015-03 | PN-EN 62368-1:2015-03/A11:2017-09
175 Audio/video, information technology and telecommunications equipment Heating - temperature measurement PN-EN IEC 62368-1:2020-11 | PN-EN IEC 62368-1:2024-06 | IEC 62368-1:2023 | PN-EN 60950-1:2007 | PN-EN 62368-1:2015-03 | PN-EN 62368-1:2015-03/A11:2017-09
176 Plastics Determination of mechanical properties in static tension
tensile strength nominal strain
PN-EN ISO 527-1:2020-01 | PN-EN ISO 527-2:2012 | PN-EN ISO 527-2:2012/Ap1:2013-09 | PN-EN ISO 527-4:2022-06 | PN-EN ISO 527-4:2023-10
177 Medical electrical equipment Power input, Humidity preconditioning, Durability of marking, Impedance and current-carrying capacity, Electric strength, Mechanical strength and resistance to heat, Distances filled with insulating compound, Measurement of creepage distances and clearances, Instability – loss of balance, Testing of the IP degree of protection, Pressure tests, Impact test, Drop test, Mechanical strength PN-EN 60601-1:2011 cl. 4.11; 5.7; 7.1.3; 8.6.4; 8.8.3; 8.8.4.1; 8.9.3; 8.9.4; 9.4.2; 11.6.5; 15.3.2; 15.3.3; 15.3.4; 15.4.7.1; 15.4.7.3; 15.5.2; | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03
178 Electric vehicle battery charging stations supplied from AC mains Insulation resistance, Touch current, AC voltage withstand, Durability of marking test PN-EN IEC 61851-1:2019-10 cl. 12.5; 12.6; 12.7; 16.5 | PN-EN IEC 61851-1:2019-10/AC:2024-02 | PN-EN 61851-22:2002
179 DC electric vehicle charging stations Insulation resistance, Touch current, AC voltage withstand, Durability of marking test PN-EN IEC 61851-1:2019-10 cl. 12.5; 12.6; 12.7; 16.5 | PN-EN IEC 61851-1:2019-10/AC:2024-02 | PN-EN 61851-23:2014-11 cl. 11.5; 11.7 | PN-EN 61851-23:2014-11/AC:2016-08
180 Motor-operated electric tools, hand-held, transportable, lawn and other garden tools Input current, Heating, Resistance to heat and fire, Mechanical strength, Earthing continuity, Insulation distances PN-EN 62841-1:2015-11 cl. 11; 12; 13; 20.2; 26.5; 28 | PN-EN 62841-1:2015-11/AC:2016-01 | PN-EN 62841-1:2015-11/A11:2023-02
181 Hand-held drills and impact drills Input current, Heating, Resistance to heat and fire, Mechanical strength, Earthing continuity, Insulation distances PN-EN 62841-1:2015-11 cl. 11; 12; 13; 20.2; 26.5; 28 | PN-EN 62841-1:2015-11/AC:2016-01 | PN-EN 62841-1:2015-11/A11:2023-02 | PN-EN 62841-1-2-1:2018-03 | PN-EN 62841-1-2-1:2018-03/A11:2020-03 | PN-EN 62841-1-2-1:2018-03/A1:2023-04 | PN-EN 62841-1-2-1:2018-03/A12:2023-05
182 Hand-held screwdrivers and impact wrenches Input current, Heating, Resistance to heat and fire, Mechanical strength, Earthing continuity, Insulation distances PN-EN 62841-1:2015-11 cl. 11; 12; 13; 20.2; 26.5; 28 | PN-EN 62841-1:2015-11/AC:2016-01 | PN-EN 62841-1:2015-11/A11:2023-02 | PN-EN 62841-1-2-2:2015-03 | PN-EN 62841-1-2-2:2015-03/AC:2016-01

Reference standards (294)

ASTM B117-11
BMW AA-0324:2018-04 excluding the assessment according to standard GS 90010 (cl. 4.0)
D45 1333 (Renault)
DIN 75200:1980-09
EN 60079-0:2012
EN 60079-11:2012
EN 60079-15:2010
EN 60079-18:2015
EN 60079-1:2014
EN 60079-1:2014 cl. 5,6,7,8,9,10,11,12,13
EN 60079-25:2010
EN 60079-26:2015
EN 60079-2:2014
EN 60079-31:2014
EN 60079-7:2015
EN 60529:1991+A1:2000
EN 60529:1991/A2:2013
EN 71-1:2014+A1:2018
EN 71-2:2020
EN IEC 60034-5:2020
EN IEC 60079-0:2018
EN IEC 60079-15:2019
EN IEC 60079-25:2022
EN IEC 60079-26:2024
EN IEC 60079-31:2024
EN ISO 80079-36:2016
FMVSS 302
GB 8410:2006
IEC 60034-5:2020
IEC 60068-2-14:2023
IEC 60079-0:2012
IEC 60079-0:2017
IEC 60079-11:2011
IEC 60079-11:2023
IEC 60079-15:2010
IEC 60079-15:2017
IEC 60079-18:2014
IEC 60079-1:2014
IEC 60079-1:2014 cl. 5,6,7,8,9,10,11,12,13
IEC 60079-25:2010
IEC 60079-25:2020
IEC 60079-26:2014
IEC 60079-26:2021
IEC 60079-28 edition 2.0 2015-05
IEC 60079-2:2014
IEC 60079-31:2013
IEC 60079-31:2022
IEC 60079-7:2015
IEC 60335-1:2020
IEC 60529:1989/AMD2:2013
IEC 60529:2001
IEC 60695-10-2:2014
IEC 60695-11-5:2016
IEC 60695-2-10:2021
IEC 60695-2-11:2021
IEC 60695-2-12:2021
IEC 60695-2-13:2021
IEC 61439-5:2023
IEC 62208:2023
IEC 62368-1:2023
ISO 20653:2023 (E)
ISO 80079-36:2016
JIS D 1201 (J) / cl. 6
PN-93-C-05013
PN-EN 1670:2008
PN-EN 2591-307:2012 excluding 5.4
PN-EN 50102:2001
PN-EN 50102:2001/AC:2011
PN-EN 60060-2:2011
PN-EN 60068-2-14:2009
PN-EN 60068-2-1:2009
PN-EN 60068-2-2:2009
PN-EN 60068-2-30:2008
PN-EN 60068-2-67:2004
PN-EN 60068-2-67:2004/A1:2019-11
PN-EN 60068-2-75:2015-01 (test Ehb)
PN-EN 60068-2-75:2015-01 (test Ehc)
PN-EN 60068-2-78:2013-11
PN-EN 60079-0:2013-03
PN-EN 60079-0:2013-03/A11:2014-03
PN-EN 60079-11:2012
PN-EN 60079-15:2010
PN-EN 60079-18:2015-06
PN-EN 60079-18:2015-06/A1:2018-02
PN-EN 60079-1:2014-12
PN-EN 60079-1:2014-12 cl. 5,6,7,8,9,10,11,12,13
PN-EN 60079-25:2011
PN-EN 60079-26:2015-04
PN-EN 60079-26:2024-09
PN-EN 60079-28:2015-12
PN-EN 60079-2:2015-02
PN-EN 60079-2:2015-02/AC1:2015-11
PN-EN 60079-31:2014-10
PN-EN 60079-31:2024-08
PN-EN 60079-32-2:2015-08
PN-EN 60079-7:2010
PN-EN 60079-7:2016-02
PN-EN 60079-7:2016-02/A1:2018-03
PN-EN 60204-1:2018-12
PN-EN 60332-1-2:2010
PN-EN 60332-1-2:2010/A11:2017-02
PN-EN 60332-1-2:2010/A12:2021-05
PN-EN 60332-1-2:2010/A1:2016-02
PN-EN 60332-2-2:2010
PN-EN 60335-1:2012 cl. 8, 10, 11, 13, 14, 15, 16, 17, 20, 21, 29, 30
PN-EN 60335-1:2012/A11:2014-10
PN-EN 60335-1:2012/A13:2017-11
PN-EN 60335-1:2012/A14:2020-05
PN-EN 60335-1:2012/A15:2022-01
PN-EN 60335-1:2012/A1:2019-10
PN-EN 60335-1:2012/A2:2019-11
PN-EN 60335-2-14:2009
PN-EN 60335-2-14:2009/A11:2012
PN-EN 60335-2-14:2009/A12:2016-03
PN-EN 60335-2-14:2009/A1:2009
PN-EN 60335-2-23:2006 +A1:2008
PN-EN 60335-2-23:2006/A11:2010E
PN-EN 60335-2-23:2006/A2:2015
PN-EN 60335-2-29:2005 +A2:2015-03
PN-EN 60335-2-29:2005/A11:2018-11
PN-EN 60335-2-2:2010
PN-EN 60335-2-2:2010/A11:2013-05
PN-EN 60335-2-30:2010
PN-EN 60335-2-30:2010/A11:2012
PN-EN 60335-2-30:2010/A12:2021-02
PN-EN 60335-2-30:2010/A13:2023-04
PN-EN 60335-2-30:2010/A1:2020-09
PN-EN 60335-2-30:2010/A2:2023-04
PN-EN 60335-2-3:2016-03
PN-EN 60335-2-54:2009
PN-EN 60335-2-54:2009/A11:2013-05
PN-EN 60335-2-54:2009/A1:2015-11
PN-EN 60335-2-54:2010/A12:2022-05
PN-EN 60335-2-54:2010/A2:2022-06
PN-EN 60335-2-8:2015
PN-EN 60335-2-8:2015/A11:2023-01
PN-EN 60335-2-8:2015/A12:2023-04
PN-EN 60335-2-8:2015/A1:2016-04
PN-EN 60335-2-8:2015/A2:2023-02
PN-EN 60529:2003
PN-EN 60529:2003/A2:2014-07
PN-EN 60598-2-10:2005
PN-EN 60598-2-10:2005/AC:2006
PN-EN 60598-2-13:2007
PN-EN 60598-2-13:2007/A11:2021-09
PN-EN 60598-2-13:2007/A1:2012
PN-EN 60598-2-13:2007/A2:2017-02
PN-EN 60598-2-22:2015-01
PN-EN 60598-2-22:2015-01/A1:2020-08 (excluding 22.17, 22.19)
PN-EN 60598-2-24:2014-02
PN-EN 60598-2-2:2012
PN-EN 60598-2-3:2006
PN-EN 60598-2-3:2006/A1:2012
PN-EN 60598-2-4:2018-06
PN-EN 60598-2-6:2000
PN-EN 60598-2-7:2000
PN-EN 60601-1:2011 cl. 4.11; 5.7; 7.1.3; 8.6.4; 8.8.3; 8.8.4.1; 8.9.3; 8.9.4; 9.4.2; 11.6.5; 15.3.2; 15.3.3; 15.3.4; 15.4.7.1; 15.4.7.3; 15.5.2;
PN-EN 60601-1:2011/A12:2014-12
PN-EN 60601-1:2011/A1:2014-02
PN-EN 60601-1:2011/A2:2022-03
PN-EN 60695-10-2:2014-10
PN-EN 60695-11-10:2014-02
PN-EN 60695-11-10:2014-02/AC:2017-08
PN-EN 60695-11-2:2017-11
PN-EN 60695-11-5:2017-08
PN-EN 60695-2-10:2013-12
PN-EN 60695-2-11:2015-02
PN-EN 60695-2-12:2011
PN-EN 60695-2-12:2011/A1:2014-10
PN-EN 60695-2-13:2011
PN-EN 60695-2-13:2011/A1:2014-10
PN-EN 60950-1:2007
PN-EN 61340-2-3:2016-11
PN-EN 61439-1:2011
PN-EN 61439-5:2015-02
PN-EN 61851-22:2002
PN-EN 61851-23:2014-11 cl. 11.5; 11.7
PN-EN 61851-23:2014-11/AC:2016-08
PN-EN 62208:2011
PN-EN 62262:2003
PN-EN 62262:2003/A1:2022-06
PN-EN 62321-3-1:2014-08
PN-EN 62368-1:2015-03
PN-EN 62368-1:2015-03/A11:2017-09
PN-EN 62841-1-2-1:2018-03
PN-EN 62841-1-2-1:2018-03/A11:2020-03
PN-EN 62841-1-2-1:2018-03/A12:2023-05
PN-EN 62841-1-2-1:2018-03/A1:2023-04
PN-EN 62841-1-2-2:2015-03
PN-EN 62841-1-2-2:2015-03/AC:2016-01
PN-EN 62841-1:2015-11 cl. 11; 12; 13; 20.2; 26.5; 28
PN-EN 62841-1:2015-11/A11:2023-02
PN-EN 62841-1:2015-11/AC:2016-01
PN-EN 71-1+A1:2018-08
PN-EN 71-1:2015-01
PN-EN 71-2+A1:2014-06
PN-EN 71-2:2021-05
PN-EN 80079-36:2016-07 Annex D
PN-EN IEC 60034-5:2021-01
PN-EN IEC 60068-2-11:2021-11
PN-EN IEC 60068-2-14:2024-04
PN-EN IEC 60068-2-38:2021-12
PN-EN IEC 60068-2-52:2018-05 Test NSS
PN-EN IEC 60068-2-5:2018
PN-EN IEC 60079-0:2018-09
PN-EN IEC 60079-0:2018-09/AC:2020-04
PN-EN IEC 60079-15:2019-06
PN-EN IEC 60079-25:2023-02
PN-EN IEC 60335-1:2024-04
PN-EN IEC 60335-1:2024-04/A11:2024-10 cl. 8, 10, 11, 13, 14, 15, 16, 17, 20, 21, 29, 30
PN-EN IEC 60335-2-14:2024-03
PN-EN IEC 60335-2-14:2024-03/A1:2024-06
PN-EN IEC 60335-2-23:2023-10
PN-EN IEC 60335-2-23:2023-10/A11:2024-02
PN-EN IEC 60335-2-23:2023-10/A1:2023-10
PN-EN IEC 60335-2-29:2022-05
PN-EN IEC 60335-2-29:2022-05/A11:2024-09
PN-EN IEC 60335-2-29:2022-05/A1:2022-06
PN-EN IEC 60335-2-2:2024-02
PN-EN IEC 60335-2-2:2024-02/A11:2024-04
PN-EN IEC 60598-1:2021-07 (excluding 4.13.6, 4.20, 4.24)
PN-EN IEC 60598-1:2021-07/A11:2022-12
PN-EN IEC 60598-2-22:2022-11
PN-EN IEC 60598-2-2:2024-06
PN-EN IEC 60695-2-10:2022-07
PN-EN IEC 60695-2-11:2022-07
PN-EN IEC 60695-2-12:2022-06
PN-EN IEC 60695-2-13:2022-05
PN-EN IEC 61439-1:2021-10
PN-EN IEC 61439-5:2024-04
PN-EN IEC 61851-1:2019-10 cl. 12.5; 12.6; 12.7; 16.5
PN-EN IEC 61851-1:2019-10/AC:2024-02
PN-EN IEC 62208:2024-04
PN-EN IEC 62368-1:2020-11
PN-EN IEC 62368-1:2024-06
PN-EN ISO 1120:2013-03
PN-EN ISO 11997-1:2017-10
PN-EN ISO 1402:2021-10
PN-EN ISO 148-1:2017-02
PN-EN ISO 16474-1:2014-02
PN-EN ISO 16474-2:2014-02
PN-EN ISO 16474-2:2014-02/A1:2023-02
PN-EN ISO 16474-3:2014-02
PN-EN ISO 20238:2019-05 excluding methods: A.1.2, A.2.2, B.1.2, B.2.2
PN-EN ISO 283:2023-10
PN-EN ISO 284:2013-06
PN-EN ISO 340:2022-12
PN-EN ISO 4589-2:2017-06
PN-EN ISO 4628-1:2016-03
PN-EN ISO 4628-2:2016-03
PN-EN ISO 4628-3:2016-03
PN-EN ISO 4628-4:2016-03
PN-EN ISO 4628-5:2023-01
PN-EN ISO 4671:2022-09
PN-EN ISO 4892-1:2016-06
PN-EN ISO 4892-2:2013-06
PN-EN ISO 4892-2:2013-06/A1:2022-01
PN-EN ISO 4892-3:2016-04
PN-EN ISO 527-1:2020-01
PN-EN ISO 527-2:2012
PN-EN ISO 527-2:2012/Ap1:2013-09
PN-EN ISO 527-4:2022-06
PN-EN ISO 527-4:2023-10
PN-EN ISO 6892-1:2020-05 Method B
PN-EN ISO 7438:2021-04
PN-EN ISO 80079-36:2016-07
PN-EN ISO 80079-36:2016-07/AC:2020-05
PN-EN ISO 8030:2014-09
PN-EN ISO 8031:2021-01
PN-EN ISO 9227:2023-02 Test NSS
PN-EN ISO 9241-305:2009 cl. 6.6.1; 6.6.3
PN-EN ISO 9773:2003
PN-EN ISO 9773:2003/A1:2005
PN-EN ISO/IEC 80079-38:2017-02
PN-G-15026:2017-04
PN-G-15050:2018-01
PN-G-15092:1999
PN-G-32000:2011
PN-G-32010:2012
PN-G-50003:2003
PN-IEC 598-2-1+A1:1994
PN-IEC 598-2-1+A1:1994/Ap1:2000
PN-ISO 3795:1996
PSA D45 1333:2020-01
PTL 8501 (Porsche)
PV 3929:2018-03
PV 3930:2017-11
UN Regulation No. 118 – Annex 6
SAE J2527:2004-02
STD 5031.19 (Volvo)
TL 1010:2008-01
UL 94 cl. 7, 8, 11 (HB, V-0, V-1, V2, VTM-0, VTM-1, VTM-2)
VDA-621-415
VW 75174:2018-10 Test L18.2

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/PL/AB%201552