🇵🇱 ARQUES Sp. z o.o. PL

PCA AB 1539 • Chodzież, Poland • 95 methods

Water & wastewaterEnvironmentMaterials & polymersMicrobiology

ARQUES Sp. z o.o. is a laboratory accredited by PCA under number AB 1539 (Chodzież, Poland). Its accreditation scope covers 95 test methods in the following areas: Water & wastewater, Environment, Materials & polymers, Microbiology. Test objects include: Water, wastewater, Sewage sludge, Waste O) code: 19 08 05, 19 09 03; O) Waste codes ac…, Water, Water intended for human consumption. Most frequently used techniques: Spectrophotometric method, Flame atomic absorption spectrometry (FAAS), Gravimetric method.

At a glance

  • Accreditation number: PCA AB 1539
  • Methods in scope: 95
  • Types of test objects: 16
  • Techniques used: 19
  • City: Chodzież, Poland
Accreditation number
AB 1539
Accreditation body
PCA
Address
ul. Mostowa 9a, 64-800 Chodzież
City
Chodzież, Poland

What this laboratory tests (16)

Analytical techniques used (19)

Certificate information

Issue date
07.07.2026
Issue no.
15

Accreditation scope — test methods (95)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Soil Sampling for chemical and physical testing PN-R-04031:1997 | PN-ISO 10381-4:2007 excluding cl. 8 | PN-ISO 10381-5:2009
2 Soil pH - in KCl, in H2O
Range 4,0 – 10,0
Potentiometric method PN-EN ISO 10390:2022-09
3 Soil Metal content
Pb (1,0 – 100) mg/kg Cd (0,50 – 7,0) mg/kg Ni (1,0 – 100) mg/kg Zn (1,0 – 500) mg/kg Cu (1,0 – 150) mg/kg Cr (1,0 – 250) mg/kg
Flame atomic absorption spectrometry (FAAS) PN-ISO 11047:2001
4 Soil Mercury content
Range (0,050 – 2,50) mg/kg
Cold vapour atomic absorption spectrometry (CVAAS) PN-ISO 16772:2009
5 Soil Available phosphorus content
Range (1,0 – 50,0) mg/100g P2O5
Spectrophotometric method PB-01 edition 2 of 25.01.2021
6 Soil Dry matter content
Range (20,0 – 99,9) %
Gravimetric method PN-EN ISO 11465:2026-03
7 Soil Loss on ignition
Range (5,0 – 75,0) %
Gravimetric method PB-10 edition 2 of 25.01.2021
8 Soil Metal content
Pb (1,0 – 1000) mg/kg Cd (0,50 – 10,0) mg/kg Ni (1,0 – 200) mg/kg Zn (1,0 – 2000) mg/kg Cu (1,0 – 250) mg/kg Cr (1,0 – 500) mg/kg Hg (0,050 – 2,50) mg/kg
Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN 16174:2012 | PN-EN ISO 22036:2024-07
9 Mineral soil Available phosphorus content
Range (1,0 – 100) mg/100g P2O5
Spectrophotometric method PN-R-04023:1996
10 Mineral soil Available magnesium content
Range (1,0 – 30,0) mg/100g
Flame atomic absorption spectrometry (FAAS) PN-R-04020:1994+Az1:2004
11 Mineral soil Available potassium content
Range (1,0 – 50,0) mg/100g K2O
Flame atomic absorption spectrometry (FAAS) PN-R-04022:1996
12 Mineral soil Available magnesium content
Range (1,0 – 30,0) mg/100g
Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-R-04020:1994+Az1:2004 | PN-EN ISO 11885:2009
13 Mineral soil Available potassium content
Range (1,0 – 50,0) mg/100g K2O
Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-R-04022:1996 | PN-EN ISO 11885:2009
14 Organic soil Available phosphorus content
Range (12,5 – 450) mg/100g P2O5
Spectrophotometric method PN-R-04024:1997
15 Organic soil Available magnesium content
Range (10,0 – 200,0) mg/100g
Flame atomic absorption spectrometry (FAAS) PN-R-04024:1997
16 Organic soil Available potassium content
Range (10,0 – 200,0) mg/100g K2O
Flame atomic absorption spectrometry (FAAS) PN-R-04024:1997
17 Organic soil Available potassium content
Range (10,0 – 200) mg/100g K2O
Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-R-04024:1997 | PN-EN ISO 11885:2009
18 Organic soil Available magnesium content
Range (10,0 – 200) mg/100g
Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-R-04024:1997 | PN-EN ISO 11885:2009
19 Sewage sludge, Waste O) code: 19 08 05; O) Waste codes according to the Regulation of the Minister of Climate on the waste catalogue. Sampling for chemical and physical testing PN-EN ISO 5667-13:2011 excluding cl. 6.3.4, 6.3.5, 6.3.8.5, 6.3.9, 6.3.10
20 Sewage sludge, Waste O) code: 19 08 05, 19 09 03, 19 08 02; O) Waste codes according to the Regulation of the Minister of Climate on the waste catalogue. Sampling for microbiological testing PB-13 edition 3 of 07.04.2022
21 Sewage sludge, Waste O) code: 19 08 05, 19 09 03, 19 08 02; O) Waste codes according to the Regulation of the Minister of Climate on the waste catalogue. Metal content
Pb (1,0 – 2000) mg/kg Cd (0,10 – 50,0) mg/kg Ni (2,5 – 1000) mg/kg Zn (5,0 – 9000) mg/kg Cu (2,5 – 2500) mg/kg Cr (2,5 – 4000) mg/kg Hg (0,050 – 25,0) mg/kg Ca (1,0 – 50) % Mg (0,20 – 5,0) % K (0,10 – 2,0) %
Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN 16174:2012 | PN-EN ISO 22036:2024-07
22 Sewage sludge, Waste O) code: 19 08 05, 19 09 03; O) Waste codes according to the Regulation of the Minister of Climate on the waste catalogue. pH
Range 4,0 – 13,0
Potentiometric method PN-ISO 12176:2004
23 Sewage sludge, Waste O) code: 19 08 05, 19 09 03; O) Waste codes according to the Regulation of the Minister of Climate on the waste catalogue. Metal content
Pb (1,0 – 1500) mg/kg Cd (0,25 – 50,0) mg/kg Ni (2,5 – 500) mg/kg Zn (5,0 – 5000) mg/kg Cu (2,5 – 2000) mg/kg
Flame atomic absorption spectrometry (FAAS) PN-ISO 8288:2002 Method A | PN-EN 13346:2002 Method B
24 Sewage sludge, Waste O) code: 19 08 05, 19 09 03; O) Waste codes according to the Regulation of the Minister of Climate on the waste catalogue. Chromium content
Range (2,5 – 2500) mg/kg
Flame atomic absorption spectrometry (FAAS) PN-EN 1233:2000 | PN-EN 13346:2002 Method B
25 Sewage sludge, Waste O) code: 19 08 05, 19 09 03; O) Waste codes according to the Regulation of the Minister of Climate on the waste catalogue. Metal content
Ca (2,0 – 50) % Mg (0,20 – 5,0) %
Flame atomic absorption spectrometry (FAAS) PN-EN ISO 7980:2002 | PN-EN 13346:2002 Method B
26 Sewage sludge, Waste O) code: 19 08 05, 19 09 03; O) Waste codes according to the Regulation of the Minister of Climate on the waste catalogue. Mercury content
Range (0,050 – 15,0) mg/kg
Cold vapour atomic absorption spectrometry (CVAAS) PB-08 edition 3 of 25.01.2021 | PN-EN 13346:2002 Method B
27 Sewage sludge, Waste O) code: 19 08 05, 19 09 03; O) Waste codes according to the Regulation of the Minister of Climate on the waste catalogue. Total phosphorus content
Range (0,50 – 4,0) %
Spectrophotometric method PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010 cl. 8 | PN-EN 13346:2002 cl. 8.4
28 Sewage sludge, Waste O) code: 19 08 05, 19 09 03; O) Waste codes according to the Regulation of the Minister of Climate on the waste catalogue. Dry matter content
Range (6,0 – 99,9) %
Gravimetric method PN-EN ISO 11465:2026-03
29 Sewage sludge, Waste O) code: 19 08 05, 19 09 03; O) Waste codes according to the Regulation of the Minister of Climate on the waste catalogue. Loss on ignition
Range (1,0 – 99,0) %
Gravimetric method PN-EN 15935:2022-01
30 Sewage sludge, Waste O) code: 19 08 05, 19 09 03; O) Waste codes according to the Regulation of the Minister of Climate on the waste catalogue. Kjeldahl nitrogen content
Range (0,50 – 10,0) %
Titrimetric method PN-EN 13342:2002
31 Sewage sludge, Waste O) code: 19 08 05, 19 09 03; O) Waste codes according to the Regulation of the Minister of Climate on the waste catalogue. Ammonium nitrogen content
Range (0,10 – 2,50) %
Titrimetric method PN-EN 14671:2007 | PN-ISO 5664:2002
32 Water, wastewater Metal concentrations
Ni (0,10 – 5,0) mg/l Zn (0,10 – 50,0) mg/l Cu (0,050 – 10,0) mg/l Pb (0,10 – 10,0) mg/l Cd (0,050 – 1,0) mg/l
Flame atomic absorption spectrometry (FAAS) PN-ISO 8288:2002 Method A
33 Water, wastewater Chromium concentration
Range (0,50 – 50,0) mg/l
Flame atomic absorption spectrometry (FAAS) PN-EN 1233:2000 cl. 3
34 Water, wastewater Chemical oxygen demand - COD-Cr
Range (6,0 – 10000) mg/l O2
Spectrophotometric method PN-ISO 15705:2005
35 Water, wastewater Total suspended solids (TSS)
Range (5,0 – 2500) mg/l
Gravimetric method PN-EN 872:2007+Ap1:2007
36 Water, wastewater Total phosphorus concentration
Range (0,10 – 40,0) mg/l
Spectrophotometric method PN-EN ISO 6878:2006 cl. 7 +Ap1:2010+Ap2:2012
37 Water, wastewater Nitrate nitrogen concentration
Range (0,10 – 50,0) mg/l N-NO3 Range (0,44 – 221) mg/l NO3
Spectrophotometric method PN-82/C-04576/08
38 Water, wastewater Nitrite nitrogen concentration
Range (0,010 – 10,0) mg/l N-NO2 Range (0,033 – 32,8) mg/l NO2
Spectrophotometric method PN-EN 26777:1999
39 Water, wastewater Kjeldahl nitrogen concentration
Range (2,00 – 500) mg/l
Titrimetric method PN-EN 25663:2001
40 Water, wastewater Total nitrogen concentration (calculated) PN-73/C-04576/14
41 Water, wastewater Chloride concentration
Range (5,0 – 1000) mg/l
Titrimetric method PN-ISO 9297:1994
42 Water, wastewater Fluoride concentration
Range (0,10 – 25,0) mg/l
Spectrophotometric method PB-12 edition 2 of 25.01.2021, using Hach Lange LCK 323 cuvette tests
43 Water, wastewater Chromium(VI) concentration
Range (0,010 – 5,0) mg/l
Spectrophotometric method PN-77/C-04604-08
44 Water, wastewater Iron concentration
Range (0,010 – 10,0) mg/l
Spectrophotometric method PN-ISO 6332:2001+Ap1:2016-06
45 Water, wastewater Total content of calcium and magnesium (total hardness)
Range (5 – 1000) mg/l CaCO3
Titrimetric method PN-ISO 6059:1999
46 Water, wastewater Biochemical oxygen demand - BOD5
Range (3,0 – 4000) mg/l O2
Electrochemical method PN-EN ISO 5815-1:2019-12
47 Water, wastewater Biochemical oxygen demand - BOD5
Range (0,5 – 6,0) mg/l O2
Electrochemical method PN-EN 1899-2:2002
48 Water, wastewater pH
Range 4,0 – 10,0
Potentiometric method PN-EN ISO 10523:2012
49 Water, wastewater Phenol index
Range (0,010 – 5,0) mg/l
Spectrophotometric method PN-ISO 6439:1994
50 Water, wastewater Mineral oil index
Range (0,10 – 100) mg/l
Gas chromatography with flame ionization detection (GC-FID) PN-EN ISO 9377-2:2003
51 Water, wastewater Sulfate concentration
Range (10,0 – 500) mg/l
Gravimetric method PN-ISO 9280:2002
52 Water, wastewater Ammonium nitrogen concentration
Range (5,0 – 300) mg/l
Titrimetric method PN-ISO 5664:2002
53 Water, wastewater Free and total chlorine concentration
Range (0,05 – 4,50) mg/l
Colorimetric method PB-15 edition 4 of 13.02.2026, using Merck cuvette tests 1.00599.0001
54 Water, wastewater Settleable solids
Range (0,5 – 100) ml/l
Volumetric method PN-72/C-04559/03
55 Water, wastewater Electrical conductivity
Range (100 – 6000) µS/cm
Conductometric method PN-EN 27888:1999
56 Water, wastewater Manganese concentration
Range (0,010 – 1,0) mg/l
Flame atomic absorption spectrometry (FAAS) PB-04 edition 2 of 25.01.2021
57 Water, wastewater Metal concentrations
Ni (0,010 – 10,0) mg/l Zn (0,010 – 50,0) mg/l Cu (0,010 – 10,0) mg/l Pb (0,010 – 10,0) mg/l Cd (0,010 – 1,0) mg/l Cr (0,010 – 50,0) mg/l Mn (0,005 – 2,0) mg/l Ca (0,25 – 600) mg/l Al (0,010 – 50,0) mg/l Mg (0,25 – 250) mg/l Na (0,25 – 500) mg/l Sn (0,010 – 10,0) mg/l V (0,010 – 5,00) mg/l As (0,010 – 2,0) mg/l Ti (0,010 – 2,0) mg/l Se (0,050– 2,0) mg/l Mo (0,010 – 5,0) mg/l B (0,010 – 5,00) mg/l Be (0,010 – 2,00) mg/l Ba (0,010 – 5,0) mg/l Co (0,010 – 2,0) mg/l Sb (0,050 – 2,0) mg/l K (0,50 – 1000) mg/l Ag (0,010 – 2,00) mg/l
Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN ISO 11885:2009
58 Water, wastewater Mercury concentration
Range (0,005 – 2,0) mg/l
Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN ISO 11885:2009 | PB-21 edition 1 of 23.02.2026
59 Water, wastewater Dry residue
Range (10 – 250 000) mg/l
Gravimetric method PN-78/C-04541
60 Water, wastewater Total dissolved solids concentration (TDS)
Range (10 – 50 000) mg/l
Gravimetric method PN-EN 15216:2022-03
61 Water Sampling for chemical and physical testing PN-EN ISO 5667-6:2016-12 excluding cl. 7.5, 7.6, 10.6
62 Water Temperature
Range (5,0 – 35,0) °C
PN-77/C-04584
63 Water Sampling for chemical and physical testing PN-ISO 5667-11:2017-10 excluding cl. 5.2, 6.1.2, 6.2, 6.3
64 Water Temperature
Range (5,0 – 35,0) °C
PN-77/C-04584
65 Water Groundwater level
Range (0,1 – 50,0) m
PB-17 edition 1 of 29.01.2025
66 Water Sampling for chemical and physical testing PN-ISO 5667-4:2017-10 excluding cl. 13, 14, 15
67 Water Temperature
Range (5,0 – 35,0) °C
PN-77/C-04584
68 Water pH
Range 4,0 – 10,0
Potentiometric method PN-EN ISO 10523:2012
69 Water Ammonium ion concentration
Range (0,05 – 3,00) mg/l N-NH4 Range (0,06 – 3,86) mg/l NH4
Spectrophotometric method PN-ISO 7150-1:2002
70 Water Colour
Range (5,0 – 70,0) mg/l Pt
Spectrophotometric method PN-EN ISO 7887:2012 Method C
71 Water Turbidity
Range (0,20 – 40) NTU
Nephelometric method PN-EN ISO 7027-1:2016-09
72 Wastewater, rainwater and snowmelt water Sampling for chemical and physical testing Manual method PN-ISO 5667-10:2021-11
73 Wastewater, rainwater and snowmelt water Temperature
Range (5,0 – 35,0) °C
PN-77/C-04584
74 Swimming pool water Sampling for chemical and physical testing PB-20 edition 1 of 13.02.2026
75 Bathing water, swimming pool water Sampling for microbiological testing PN-EN ISO 19458:2007
76 Wastewater Mercury concentration
Range (0,005 – 2,0) mg/l
Cold vapour atomic absorption spectrometry (CVAAS) PN-EN ISO 12846:2012 cl. 7 +Ap1:2016-07
77 Water, water intended for human consumption, wastewater Phosphate concentration
Range (0,150 – 100,0) mg/l
Spectrophotometric method PN-EN ISO 6878:2006 cl. 4 +Ap1:2010+Ap2:2012
78 Water intended for human consumption Sampling for chemical and physical testing (including sensory testing) PN-ISO 5667-5:2017-10
79 Water intended for human consumption Temperature
Range (5,0 – 35,0) °C
PN-77/C-04584
80 Water intended for human consumption Sampling for microbiological testing PN-EN ISO 19458:2007
81 Water intended for human consumption Taste threshold number TFN
Range 1
Simplified method, paired, non-forced choice PN-EN 1622:2006
82 Water intended for human consumption Odour threshold number TON
Range 1
Simplified method, paired, non-forced choice PN-EN 1622:2006
83 Water intended for human consumption Total viable count at 22°C Plate method (pour plate) PN-EN ISO 6222:2004
84 Water intended for human consumption Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04
85 Water intended for human consumption Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04
86 Water intended for human consumption Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004
87 Water, water intended for human consumption Total viable count at 36°C Plate method (pour plate) PN-EN ISO 6222:2004
88 Water, water intended for human consumption Oxidation-reduction (redox) potential vs. Ag/AgCl 3,5 mol/l KCl
Range (200 – 800) mV
Potentiometric method PB-19 edition 1 of 13.02.2026
89 Water Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004
90 Sewage sludge, Waste O) code: 19 08 05, 19 09 03; O) Waste codes according to the Regulation of the Minister of Climate on the waste catalogue. Presence of Salmonella bacteria in 100 g Culture method with biochemical and serological confirmation PB-16 edition 3 of 01.06.2022
91 Sewage sludge, Waste O) code: 19 08 05, 19 09 03; O) Waste codes according to the Regulation of the Minister of Climate on the waste catalogue. Number of viable eggs of intestinal parasites Ascaris sp., Trichuris sp. and Toxocara sp.
Range from 1 egg/50 g Range from 1 egg/kg of dry matter
Isolation, flotation, incubation and microscopic observation method PN-Z-19005:2018-10
92 Waste O) code: 10 01 01, 10 01 02, 10 01 03, 10 13 80, 10 13 81, 12 01 99, 17 03 80, 17 06 04, 17 09 04, 19 05 03, 19 05 99, 19 08 01, 19 08 02, 19 08 05, 19 09 02, 19 09 03, 19 12 12, 20 01 99, 20 03 03, 20 03 06, 20 03 99; O) Waste codes according to the Regulation of the Minister of Climate on the waste catalogue. Sampling for chemical and physical testing
Regulated area: Sampling and tests performed for the purposes of the regulated area covered by the Regulation of the Minister of Economy of 16 July 2015 on the admission of waste to landfills (Journal of Laws 2015, item 1277)
PB-03 edition 5 of 17.04.2023
93 Waste O) code: 10 01 01, 10 01 02, 10 01 03, 10 13 80, 10 13 81, 12 01 99, 17 03 80, 17 06 04, 17 09 04, 19 05 03, 19 05 99, 19 08 01, 19 08 02, 19 08 05, 19 09 02, 19 09 03, 19 12 12, 20 01 99, 20 03 03, 20 03 06, 20 03 99; O) Waste codes according to the Regulation of the Minister of Climate on the waste catalogue. pH
Range 4,0 – 10,0
Regulated area: Sampling and tests performed for the purposes of the regulated area covered by the Regulation of the Minister of Economy of 16 July 2015 on the admission of waste to landfills (Journal of Laws 2015, item 1277)
Potentiometric method PN-ISO 12176:2004
94 Waste O) code: 10 01 01, 10 01 02, 10 01 03, 10 13 80, 10 13 81, 12 01 99, 17 03 80, 17 06 04, 17 09 04, 19 05 03, 19 05 99, 19 08 01, 19 08 02, 19 08 05, 19 09 02, 19 09 03, 19 12 12, 20 01 99, 20 03 03, 20 03 06, 20 03 99; O) Waste codes according to the Regulation of the Minister of Climate on the waste catalogue. Dry matter content
Range (6,0 – 99,9) %
Regulated area: Sampling and tests performed for the purposes of the regulated area covered by the Regulation of the Minister of Economy of 16 July 2015 on the admission of waste to landfills (Journal of Laws 2015, item 1277)
Gravimetric method PN-EN ISO 11465:2026-03
95 Waste O) code: 10 01 01, 10 01 02, 10 01 03, 10 13 80, 10 13 81, 12 01 99, 17 03 80, 17 06 04, 17 09 04, 19 05 03, 19 05 99, 19 08 01, 19 08 02, 19 08 05, 19 09 02, 19 09 03, 19 12 12, 20 01 99, 20 03 03, 20 03 06, 20 03 99; O) Waste codes according to the Regulation of the Minister of Climate on the waste catalogue. Loss on ignition
Range (1,0 – 99,0) %
Regulated area: Sampling and tests performed for the purposes of the regulated area covered by the Regulation of the Minister of Economy of 16 July 2015 on the admission of waste to landfills (Journal of Laws 2015, item 1277)
Gravimetric method PN-EN 15935:2022-01

Reference standards (78)

PB-01 edition 2 of 25.01.2021
PB-03 edition 5 of 17.04.2023
PB-04 edition 2 of 25.01.2021
PB-08 edition 3 of 25.01.2021
PB-10 edition 2 of 25.01.2021
PB-12 edition 2 of 25.01.2021, using Hach Lange LCK 323 cuvette tests
PB-13 edition 3 of 07.04.2022
PB-15 edition 4 of 13.02.2026, using Merck cuvette tests 1.00599.0001
PB-16 edition 3 of 01.06.2022
PB-17 edition 1 of 29.01.2025
PB-19 edition 1 of 13.02.2026
PB-20 edition 1 of 13.02.2026
PB-21 edition 1 of 23.02.2026
PN-72/C-04559/03
PN-73/C-04576/14
PN-77/C-04584
PN-77/C-04604-08
PN-78/C-04541
PN-82/C-04576/08
PN-EN 1233:2000
PN-EN 1233:2000 cl. 3
PN-EN 13342:2002
PN-EN 13346:2002 Method B
PN-EN 13346:2002 cl. 8.4
PN-EN 14671:2007
PN-EN 15216:2022-03
PN-EN 15935:2022-01
PN-EN 16174:2012
PN-EN 1622:2006
PN-EN 1899-2:2002
PN-EN 25663:2001
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10390:2022-09
PN-EN ISO 10523:2012
PN-EN ISO 11465:2026-03
PN-EN ISO 11885:2009
PN-EN ISO 12846:2012 cl. 7 +Ap1:2016-07
PN-EN ISO 19458:2007
PN-EN ISO 22036:2024-07
PN-EN ISO 5667-13:2011 excluding cl. 6.3.4, 6.3.5, 6.3.8.5, 6.3.9, 6.3.10
PN-EN ISO 5667-6:2016-12 excluding cl. 7.5, 7.6, 10.6
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6222:2004
PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010 cl. 8
PN-EN ISO 6878:2006 cl. 4 +Ap1:2010+Ap2:2012
PN-EN ISO 6878:2006 cl. 7 +Ap1:2010+Ap2:2012
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7887:2012 Method C
PN-EN ISO 7899-2:2004
PN-EN ISO 7980:2002
PN-EN ISO 9308-1:2014-12 +A1:2017-04
PN-EN ISO 9377-2:2003
PN-ISO 10381-4:2007 excluding cl. 8
PN-ISO 10381-5:2009
PN-ISO 11047:2001
PN-ISO 12176:2004
PN-ISO 15705:2005
PN-ISO 16772:2009
PN-ISO 5664:2002
PN-ISO 5667-10:2021-11
PN-ISO 5667-11:2017-10 excluding cl. 5.2, 6.1.2, 6.2, 6.3
PN-ISO 5667-4:2017-10 excluding cl. 13, 14, 15
PN-ISO 5667-5:2017-10
PN-ISO 6059:1999
PN-ISO 6332:2001+Ap1:2016-06
PN-ISO 6439:1994
PN-ISO 7150-1:2002
PN-ISO 8288:2002 Method A
PN-ISO 9280:2002
PN-ISO 9297:1994
PN-R-04020:1994+Az1:2004
PN-R-04022:1996
PN-R-04023:1996
PN-R-04024:1997
PN-R-04031:1997
PN-Z-19005:2018-10

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/PL/AB%201539