🇵🇱 ZABRZAŃSKIE PRZEDSIĘBIORSTWO WODOCIĄGÓW PL

PCA AB 1380 • Zabrze, Poland • 86 methods

Water & wastewaterMicrobiology

ZABRZAŃSKIE PRZEDSIĘBIORSTWO WODOCIĄGÓW is a laboratory accredited by PCA under number AB 1380 (Zabrze, Poland). Its accreditation scope covers 86 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water intended for human consumption, Water, Water, Wastewater, Wastewater. Most frequently used techniques: Spectrophotometric method, Titrimetric method, Membrane filtration method.

At a glance

  • Accreditation number: PCA AB 1380
  • Methods in scope: 86
  • Types of test objects: 5
  • Techniques used: 12
  • City: Zabrze, Poland
Accreditation number
AB 1380
Accreditation body
PCA
Address
I KANALIZACJI Sp. z o.o., ul. Wolności 215, 41-800 Zabrze, LABORATORIUM, ul. Pestalozziego 10
City
Zabrze, Poland

What this laboratory tests (5)

Analytical techniques used (12)

Laboratory sections (2)

Laboratory locations

Certificate information

Issue date
15.10.2026
Issue no.
14

Accreditation scope — test methods (86)

No. Test object Methodology / Parameters Technique Reference document
Laboratory
1 Water Sampling for microbiological testing PN-EN ISO 19458:2007 excluding cl. 4.4.3; 4.4.4; 4.4.5
2 Water Sampling for chemical and physical testing PN-EN ISO 5667-6:2016-12 excluding cl. 7.3, 7.5, 7.6, 8.2
3 Water Temperature
Range (5,0 – 50,0) °C
PB-13 issue 4 of 19.06.2020
4 Wastewater Sampling for chemical and physical testing Manual method; Automatic method PN-ISO 5667-10:2021-11
5 Wastewater Temperature
Range (5,0 – 50,0) °C
PB-13 issue 4 of 19.06.2020
6 Water pH
Range 4,0 – 10,0
Potentiometric method PN-EN ISO 10523:2012
7 Water Iron concentration
Range (0,010 – 2,500) mg/l
Spectrophotometric method PB-03 issue 9 of 06.07.2026 based on Hach methodology No. 8008
8 Water Manganese concentration
Range (0,010 – 0,500) mg/l
Spectrophotometric method PB-04 issue 8 of 19.06.2020 based on Hach methodology No. 8149
9 Water Ammonium ion concentration
Range (0,020 – 2,500) mg/l
Spectrophotometric method PB-05 issue 8 of 19.06.2020 based on Hach methodology No. 8038
10 Water Colour
Range (2 – 100) mg/l Pt
Spectrophotometric method PB-06 issue 9 of 06.07.2026 based on Hach methodology No. 8025
11 Water Electrical conductivity
Range (147 – 2500) µS/cm
Conductometric method PN-EN 27888:1999
12 Water Turbidity
Range (0,10 – 30) NTU
Nephelometric method PN-EN ISO 7027-1:2016-09
13 Water Total content of calcium and magnesium (total hardness)
Range (5 – 700) mg/l CaCO3
Titrimetric method PN-ISO 6059:1999
14 Water Chloride concentration
Range (5 – 300) mg/l
Titrimetric method PN-ISO 9297:1994
15 Water Nitrate concentration
Range (0,6 – 75) mg/l
Spectrophotometric method PN-82/C-04576/08
16 Water Calcium concentration
Range (2 – 150) mg/l
Titrimetric method PN-ISO 6058:1999
17 Water Magnesium concentration (calculated) PN-C-04554-4:1999; Annex A
18 Water Permanganate index (oxidisability)
Range (0,50 – 10,0) mg/l
Titrimetric method PN-EN ISO 8467:2001
19 Water Sulfate concentration
Range (5 – 300) mg/l
Spectrophotometric method PB-22 issue 5 of 19.06.2020 based on Hach methodology No. 8051
20 Water intended for human consumption Total chlorine concentration
Range (0,10 – 1,00) mg/l
Spectrophotometric method PB-61 issue 2 of 25.09.2024 based on Hach methodologies No. 8167 and 8021
21 Water intended for human consumption Combined chlorine concentration (calculated) PB-61 issue 2 of 25.09.2024 based on Hach methodologies No. 8167 and 8021
22 Water Fluoride concentration
Range (0,10 – 1,90) mg/l
Spectrophotometric method PB-56 issue 5 of 19.06.2020 based on Hach methodology No. 8029
23 Water Cyanide concentration
Range (0,010 – 0,200) mg/l
Spectrophotometric method PB-20 issue 5 of 19.06.2020 based on Hach methodology No. 8027
24 Water Nitrite concentration
Range (0,010 – 0,800) mg/l
Spectrophotometric method PN-EN 26777:1999
25 Water Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04
26 Water Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04
27 Water Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004
28 Water Clostridium perfringens count including spores Membrane filtration method PN-EN ISO 14189:2016-10
29 Water Total viable count at 36°C Plate method (pour plate) PN-EN ISO 6222:2004
30 Water Total viable count at 22°C Plate method (pour plate) PN-EN ISO 6222:2004
31 Water Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266:2009
32 Water Escherichia coli count Most probable number method (MPN) PN-EN ISO 9308-2:2014-06
33 Water Coliform bacteria count Most probable number method (MPN) PN-EN ISO 9308-2:2014-06
34 Water Chemical oxygen demand - COD-Cr
Range (5 – 30000) mg/l O2
Spectrophotometric method PN-ISO 15705:2005
35 Water Biochemical oxygen demand - BOD5
Range (0,50 – 6,0) mg/l O2
Electrochemical method PN-EN 1899-2:2002
36 Water, Water intended for human consumption Intestinal enterococci count Most probable number method (MPN) PB-18 issue 4 of 19.06.2020
37 Wastewater Chemical oxygen demand - COD-Cr
Range (30 – 5000) mg/l O2
Titrimetric method PN-ISO 6060:2006
38 Wastewater Ammonium nitrogen concentration
Range (2,00 – 1100) mg/l
Titrimetric method PN-ISO 5664:2002
39 Water, Wastewater pH
Range 2,0 – 12,0
Potentiometric method PN-EN ISO 10523:2012
40 Water, Wastewater Biochemical oxygen demand - BOD5
Range (3 – 2000) mg/l O2
Electrochemical method PN-EN ISO 5815-1:2019-12
41 Water, Wastewater Total suspended solids (TSS)
Range (2,0 – 1100) mg/l
Gravimetric method PN-EN 872:2007+Ap1:2007
42 Water, Wastewater Nitrate nitrogen concentration
Range (0,05 – 25) mg/l
Spectrophotometric method PN-82/C-04576/08
43 Water, Wastewater Total nitrogen (calculated) PB-12 issue 7 of 19.06.2020
44 Water, Wastewater Chloride concentration
Range (5,0 – 5000) mg/l
Titrimetric method PN-ISO 9297:1994
45 Water, Wastewater Sulfate concentration
Range (10 – 1000) mg/l
Gravimetric method PN-ISO 9280:2002
46 Water, Wastewater Nitrite nitrogen concentration
Range (0,010 – 2,50) mg/l
Spectrophotometric method PN-EN 26777:1999
47 Water, Wastewater Kjeldahl nitrogen concentration
Range (1,00 – 1000) mg/l
Titrimetric method PN-EN 25663:2001
48 Water, Wastewater Total phosphorus concentration
Range (0,040 – 75,0) mg/l
Spectrophotometric method PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 cl. 7
49 Water, Wastewater Electrical conductivity
Range (200 – 100 000) µS/cm
Conductometric method PN-EN 27888:1999
50 Water, Wastewater Ammonium nitrogen concentration
Range (0,05 – 1000) mg/l
Spectrophotometric method PN-ISO 7150-1:2002
51 Water, Wastewater Phenol index
Range (0,004 – 1,0) mg/l
Spectrophotometric method PN-ISO 6439:1994
52 Water, Wastewater Chemical oxygen demand - COD-Cr
Range (5 – 30000) mg/l O2
Spectrophotometric method PN-ISO 15705:2005
53 Water, Wastewater Biochemical oxygen demand - BOD5
Range (0,50 – 6,0) mg/l O2
Electrochemical method PN-EN 1899-2:2002
54 Water intended for human consumption Sampling for chemical and physical testing
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
PN-ISO 5667-5:2017-10
55 Water intended for human consumption Temperature
Range (5,0 – 20,0) °C
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
PN-77/C-04584
56 Water intended for human consumption Sampling for microbiological testing
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
PN-EN ISO 19458:2007
57 Water intended for human consumption pH
Range 4,0 – 10,0
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
Potentiometric method PN-EN ISO 10523:2012
58 Water intended for human consumption Iron concentration
Range (0,010 – 2,500) mg/l
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
Spectrophotometric method PB-03 issue 9 of 06.07.2026 based on Hach methodology No. 8008
59 Water intended for human consumption Manganese concentration
Range (0,010 – 0,500) mg/l
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
Spectrophotometric method PB-04 issue 8 of 19.06.2020 based on Hach methodology No. 8149
60 Water intended for human consumption Ammonium ion concentration
Range (0,020 – 2,500) mg/l
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
Spectrophotometric method PB-05 issue 8 of 19.06.2020 based on Hach methodology No. 8038
61 Water intended for human consumption Colour
Range (2 – 100) mg/l Pt
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
Spectrophotometric method PB-06 issue 9 of 06.07.2026 based on Hach methodology No. 8025
62 Water intended for human consumption Electrical conductivity
Range (147 – 2500) µS/cm
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
Conductometric method PN-EN 27888:1999
63 Water intended for human consumption Turbidity
Range (0,10 – 30) NTU
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
Nephelometric method PN-EN ISO 7027-1:2016-09
64 Water intended for human consumption Total content of calcium and magnesium (total hardness)
Range (5 – 700) mg/l CaCO3
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
Titrimetric method PN-ISO 6059:1999
65 Water intended for human consumption Chloride concentration
Range (5 – 300) mg/l
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
Titrimetric method PN-ISO 9297:1994
66 Water intended for human consumption Nitrate concentration
Range (0,6 – 75) mg/l
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
Spectrophotometric method PN-82/C-04576/08
67 Water intended for human consumption Calcium concentration
Range (2 – 150) mg/l
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
Titrimetric method PN-ISO 6058:1999
68 Water intended for human consumption Magnesium concentration (calculated)
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
PN-C-04554-4:1999; Annex A
69 Water intended for human consumption Permanganate index (oxidisability)
Range (0,50 – 10,0) mg/l
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
Titrimetric method PN-EN ISO 8467:2001
70 Water intended for human consumption Sulfate concentration
Range (5 – 300) mg/l
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
Spectrophotometric method PB-22 issue 5 of 19.06.2020 based on Hach methodology No. 8051
71 Water intended for human consumption Free chlorine concentration
Range (0,10 – 0,60) mg/l
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
Spectrophotometric method PB-25 issue 5 of 19.06.2020 based on Hach methodology No. 8021
72 Water intended for human consumption Fluoride concentration
Range (0,10 – 1,90) mg/l
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
Spectrophotometric method PB-56 issue 5 of 19.06.2020 based on Hach methodology No. 8029
73 Water intended for human consumption Cyanide concentration
Range (0,010 – 0,200) mg/l
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
Spectrophotometric method PB-20 issue 5 of 19.06.2020 based on Hach methodology No. 8027
74 Water intended for human consumption Nitrite concentration
Range (0,010 – 0,800) mg/l
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
Spectrophotometric method PN-EN 26777:1999
75 Water intended for human consumption Escherichia coli count
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04
76 Water intended for human consumption Coliform bacteria count
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04
77 Water intended for human consumption Intestinal enterococci count
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
Membrane filtration method PN-EN ISO 7899-2:2004
78 Water intended for human consumption Clostridium perfringens count including spores
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
Membrane filtration method PN-EN ISO 14189:2016-10
79 Water intended for human consumption Total viable count at 36°C
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
Plate method (pour plate) PN-EN ISO 6222:2004
80 Water intended for human consumption Total viable count at 22°C
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
Plate method (pour plate) PN-EN ISO 6222:2004
81 Water intended for human consumption Pseudomonas aeruginosa count
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
Membrane filtration method PN-EN ISO 16266:2009
82 Water intended for human consumption Escherichia coli count
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
Most probable number method (MPN) PN-EN ISO 9308-2:2014-06
83 Water intended for human consumption Coliform bacteria count
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
Most probable number method (MPN) PN-EN ISO 9308-2:2014-06
Laboratory Tests performed outside the laboratory premises
84 Water intended for human consumption Total chlorine concentration
Range (0,10 – 1,00) mg/l
Colorimetric method PB-60 issue 2 of 25.09.2024 based on Hach methodologies No. 8167 and 8021
85 Water intended for human consumption Combined chlorine concentration (calculated) PB-60 issue 2 of 25.09.2024 based on Hach methodologies No. 8167 and 8021
86 Water intended for human consumption Free chlorine concentration
Range (0,10 – 0,60) mg/l
Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal.
Colorimetric method PB-59 issue 2 of 19.06.2020 based on Hach methodology No. 8021

Reference standards (47)

PB-03 issue 9 of 06.07.2026 based on Hach methodology No. 8008
PB-04 issue 8 of 19.06.2020 based on Hach methodology No. 8149
PB-05 issue 8 of 19.06.2020 based on Hach methodology No. 8038
PB-06 issue 9 of 06.07.2026 based on Hach methodology No. 8025
PB-12 issue 7 of 19.06.2020
PB-13 issue 4 of 19.06.2020
PB-18 issue 4 of 19.06.2020
PB-20 issue 5 of 19.06.2020 based on Hach methodology No. 8027
PB-22 issue 5 of 19.06.2020 based on Hach methodology No. 8051
PB-25 issue 5 of 19.06.2020 based on Hach methodology No. 8021
PB-56 issue 5 of 19.06.2020 based on Hach methodology No. 8029
PB-59 issue 2 of 19.06.2020 based on Hach methodology No. 8021
PB-60 issue 2 of 25.09.2024 based on Hach methodologies No. 8167 and 8021
PB-61 issue 2 of 25.09.2024 based on Hach methodologies No. 8167 and 8021
PN-77/C-04584
PN-82/C-04576/08
PN-C-04554-4:1999; Annex A
PN-EN 1899-2:2002
PN-EN 25663:2001
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10523:2012
PN-EN ISO 14189:2016-10
PN-EN ISO 16266:2009
PN-EN ISO 19458:2007
PN-EN ISO 19458:2007 excluding cl. 4.4.3; 4.4.4; 4.4.5
PN-EN ISO 5667-6:2016-12 excluding cl. 7.3, 7.5, 7.6, 8.2
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6222:2004
PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 cl. 7
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7899-2:2004
PN-EN ISO 8467:2001
PN-EN ISO 9308-1:2014-12 +A1:2017-04
PN-EN ISO 9308-2:2014-06
PN-ISO 15705:2005
PN-ISO 5664:2002
PN-ISO 5667-10:2021-11
PN-ISO 5667-5:2017-10
PN-ISO 6058:1999
PN-ISO 6059:1999
PN-ISO 6060:2006
PN-ISO 6439:1994
PN-ISO 7150-1:2002
PN-ISO 9280:2002
PN-ISO 9297:1994

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/PL/AB%201380