🇵🇱 PHILIP MORRIS POLSKA S.A. PL

PCA AB 1356 • Kraków, Poland • 9 methods

Electronics & EMCWater & wastewater

PHILIP MORRIS POLSKA S.A. is a laboratory accredited by PCA under number AB 1356 (Kraków, Poland). Its accreditation scope covers 9 test methods in the following areas: Electronics & EMC, Water & wastewater. Test objects include: Tobacco products E, Tobacco products E: - tobacco insert for an electronic heating device. Most frequently used techniques: Gas chromatography with flame ionization detection (GC-FID), Calculation method, Combustion method in a test chamber.

At a glance

  • Accreditation number: PCA AB 1356
  • Methods in scope: 9
  • Types of test objects: 2
  • Techniques used: 8
  • City: Kraków, Poland
Accreditation number
AB 1356
Accreditation body
PCA
Address
Al. Jana Pawła II 196, 31-982 Kraków
City
Kraków, Poland

What this laboratory tests (2)

Analytical techniques used (8)

Laboratory sections (2)

Laboratory locations

Certificate information

Issue date
24.07.2026
Issue no.
21

Accreditation scope — test methods (9)

No. Test object Methodology / Parameters Technique Reference document
QUALITY CONTROL LABORATORY – CONVENTIONAL TOBACCO PRODUCTS (QC-CC)
1 Tobacco products E Water in smoke per cigarette
Range (0,100 – 4,000) mg
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gas chromatography with thermal conductivity detection (GC-TCD) ISO 10362-1
2 Tobacco products E Nicotine in smoke per cigarette
Range (0,10 – 1,50) mg
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) ISO 10315
3 Tobacco products E Carbon monoxide per cigarette
Range (1,5 – 16,5) mg
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Infrared spectrometry method (IR) ISO 8454
4 Tobacco products E Total particulate matter per cigarette
Range (1,0 – 20,0) mg
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method ISO 4387
5 Tobacco products E TAR per cigarette
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Calculation method ISO 4387
6 Tobacco products E Menthol in TPM per cigarette
Range (0,10 – 2,50) mg
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) ISO 13110
7 Tobacco products E Ignition propensity of cigarettes (RCIP Full Length Burn)
Range (0 – 100) %
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Combustion method in a test chamber PN-EN ISO 12863 | ISO 12863 | ASTM E2187
QUALITY CONTROL LABORATORY – SMOKE-FREE PRODUCTS (QC-SFP)
8 Tobacco products E: - tobacco insert for an electronic heating device Concentration of organic compounds in aerosol:
Nicotine (7,50 – 75,0) µg/ml Menthol (5,00 – 200,0) µg/ml Phenol (0,0100 – 0,190) µg/ml Glycerin (35,0 – 350,0) µg/ml Content of organic compounds (calculated)
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gas chromatography with mass spectrometry detection (GC-MS) QMS-0030847
9 Tobacco products E: - tobacco insert for an electronic heating device Carbon monoxide per stick
Range (0,06 – 0,5) mg
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Spectrometry method in the infrared range (IR) QMS-0008987

Reference standards (10)

ASTM E2187
ISO 10315
ISO 10362-1
ISO 12863
ISO 13110
ISO 4387
ISO 8454
PN-EN ISO 12863
QMS-0008987
QMS-0030847

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/PL/AB%201356