🇵🇱 PHILIP MORRIS POLSKA S.A. PL
Electronics & EMCWater & wastewater
PHILIP MORRIS POLSKA S.A. is a laboratory accredited by PCA under number AB 1356 (Kraków, Poland). Its accreditation scope covers 9 test methods in the following areas: Electronics & EMC, Water & wastewater. Test objects include: Tobacco products E, Tobacco products E: - tobacco insert for an electronic heating device. Most frequently used techniques: Gas chromatography with flame ionization detection (GC-FID), Calculation method, Combustion method in a test chamber.
At a glance
- Accreditation number: PCA AB 1356
- Methods in scope: 9
- Types of test objects: 2
- Techniques used: 8
- City: Kraków, Poland
- Accreditation number
- AB 1356
- Accreditation body
- PCA
- Address
- Al. Jana Pawła II 196, 31-982 Kraków
- City
- Kraków, Poland
What this laboratory tests (2)
- Tobacco products E — 7 methods
- Tobacco products E: - tobacco insert for an electronic heating device — 2 methods
Analytical techniques used (8)
- Gas chromatography with flame ionization detection (GC-FID) — 2 methods
- Calculation method — 1 method
- Combustion method in a test chamber — 1 method
- Gas chromatography with mass spectrometry detection (GC-MS) — 1 method
- Gas chromatography with thermal conductivity detection (GC-TCD) — 1 method
- Gravimetric method — 1 method
- Infrared spectrometry method (IR) — 1 method
- Spectrometry method in the infrared range (IR) — 1 method
Laboratory sections (2)
- QUALITY CONTROL LABORATORY – CONVENTIONAL TOBACCO PRODUCTS (QC-CC) — 7 methods
- QUALITY CONTROL LABORATORY – SMOKE-FREE PRODUCTS (QC-SFP) — 2 methods
Laboratory locations
- PHILIP MORRIS POLSKA S.A. (main site) — Al. Jana Pawła II 196, 31-982 Kraków
- QUALITY CONTROL LABORATORY – CONVENTIONAL TOBACCO PRODUCTS (QC-CC) — Al. Jana Pawła II 196, 31-982 Kraków
- QUALITY CONTROL LABORATORY – SMOKE-FREE PRODUCTS (QC-SFP) — Al. Jana Pawła II 196, 31-982 Kraków
Certificate information
- Issue date
- 24.07.2026
- Issue no.
- 21
Accreditation scope — test methods (9)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| QUALITY CONTROL LABORATORY – CONVENTIONAL TOBACCO PRODUCTS (QC-CC) | |||||
| 1 | Tobacco products E | Water in smoke per cigarette Range (0,100 – 4,000) mg Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gas chromatography with thermal conductivity detection (GC-TCD) | ISO 10362-1 | |
| 2 | Tobacco products E | Nicotine in smoke per cigarette Range (0,10 – 1,50) mg Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gas chromatography with flame ionization detection (GC-FID) | ISO 10315 | |
| 3 | Tobacco products E | Carbon monoxide per cigarette Range (1,5 – 16,5) mg Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Infrared spectrometry method (IR) | ISO 8454 | |
| 4 | Tobacco products E | Total particulate matter per cigarette Range (1,0 – 20,0) mg Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method | ISO 4387 | |
| 5 | Tobacco products E | TAR per cigarette Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Calculation method | ISO 4387 | |
| 6 | Tobacco products E | Menthol in TPM per cigarette Range (0,10 – 2,50) mg Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gas chromatography with flame ionization detection (GC-FID) | ISO 13110 | |
| 7 | Tobacco products E | Ignition propensity of cigarettes (RCIP Full Length Burn) Range (0 – 100) % Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Combustion method in a test chamber | PN-EN ISO 12863 | ISO 12863 | ASTM E2187 | |
| QUALITY CONTROL LABORATORY – SMOKE-FREE PRODUCTS (QC-SFP) | |||||
| 8 | Tobacco products E: - tobacco insert for an electronic heating device | Concentration of organic compounds in aerosol: Nicotine (7,50 – 75,0) µg/ml Menthol (5,00 – 200,0) µg/ml Phenol (0,0100 – 0,190) µg/ml Glycerin (35,0 – 350,0) µg/ml Content of organic compounds (calculated) Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gas chromatography with mass spectrometry detection (GC-MS) | QMS-0030847 | |
| 9 | Tobacco products E: - tobacco insert for an electronic heating device | Carbon monoxide per stick Range (0,06 – 0,5) mg Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Spectrometry method in the infrared range (IR) | QMS-0008987 | |
Reference standards (10)
ASTM E2187
ISO 10315
ISO 10362-1
ISO 12863
ISO 13110
ISO 4387
ISO 8454
PN-EN ISO 12863
QMS-0008987
QMS-0030847