🇵🇱 UNI-NET POLAND SP. Z O.O. PL

PCA AB 1333 • Warszawa, Poland • 17 methods

EnvironmentMaterials & polymersElectronics & EMC

UNI-NET POLAND SP. Z O.O. is a laboratory accredited by PCA under number AB 1333 (Warszawa, Poland). Its accreditation scope covers 17 test methods in the following areas: Environment, Materials & polymers, Electronics & EMC. Test objects include: Working environment − electromagnetic field from industrial install…, Environment - electromagnetic field in the vicinity of radiocommuni…, Workplace environment - electromagnetic field from transmitting dev…, Workplace environment − electromagnetic field from equipment used i…. Most frequently used techniques: Direct measurement method, Direct measurement method (simplified).

At a glance

  • Accreditation number: PCA AB 1333
  • Methods in scope: 17
  • Types of test objects: 6
  • Techniques used: 2
  • City: Warszawa, Poland
Accreditation number
AB 1333
Accreditation body
PCA
Address
LABORATORIUM BADAWCZE, ul. Bruzdowa 94A, 02-991 Warszawa
City
Warszawa, Poland

What this laboratory tests (6)

Analytical techniques used (2)

Laboratory locations

Certificate information

Issue date
18.05.2026
Issue no.
19

Accreditation scope — test methods (17)

No. Test object Methodology / Parameters Technique Reference document
Testing Laboratory
1 Working environment − electromagnetic field from industrial installations and equipment: - resistance and arc furnaces - industrial microwave furnaces, heaters and dryers - dielectric heating equipment - induction heating equipment - equipment for the production and processing of plastics - electrical discharge machines - special equipment - metal detection equipment Electric field strength:
in the frequency range from 20 Hz to 400 kHz Zakres: 1 V/m – 25 kV/m in the frequency range from 100 kHz to 800 MHz Zakres: (1,0 – 1000) V/m in the frequency range from 800 GHz to 90 GHz Zakres: (0,8 – 300) V/m
Direct measurement method PN-T-06580-3:2002 Method adapted to the regulated area | P-14 issue 16 of 24.04.2026
2 Working environment − electromagnetic field from industrial installations and equipment: - resistance and arc furnaces - industrial microwave furnaces, heaters and dryers - dielectric heating equipment - induction heating equipment - equipment for the production and processing of plastics - electrical discharge machines - special equipment - metal detection equipment Magnetic field strength:
in the frequency range from 100 kHz to 40 MHz Zakres: (0,02 – 16,0) A/m in the frequency range from 20 MHz to 1 GHz Zakres: (0,02 – 1,2) A/m
Direct measurement method PN-T-06580-3:2002 Method adapted to the regulated area | P-14 issue 16 of 24.04.2026
3 Working environment − electromagnetic field from industrial installations and equipment: - resistance and arc furnaces - industrial microwave furnaces, heaters and dryers - dielectric heating equipment - induction heating equipment - equipment for the production and processing of plastics - electrical discharge machines - special equipment - metal detection equipment Magnetic flux density:
in the frequency range from 20 Hz to 400 kHz Zakres: 1 µT – 10 mT
Direct measurement method PN-T-06580-3:2002 Method adapted to the regulated area | P-14 issue 16 of 24.04.2026
4 Working environment − electromagnetic field from industrial installations and equipment: - resistance and arc furnaces - industrial microwave furnaces, heaters and dryers - dielectric heating equipment - induction heating equipment - equipment for the production and processing of plastics - electrical discharge machines - special equipment - metal detection equipment Magnetic field strength:
in the frequency range from 20 Hz to 400 kHz in the frequency range from 800 MHz – 90 GHz (calculated)
PN-T-06580-3:2002 Method adapted to the regulated area | P-14 issue 16 of 24.04.2026
5 Workplace environment − electromagnetic field from radiocommunication and anti-theft systems: - hand-held and cordless radiotelephones, short-range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) - anti-theft and electronic article surveillance systems Electric field strength:
in the frequency range from 200 kHz to 3 GHz Zakres: (1,0 – 1000) V/m in the frequency range from 3 GHz to 90 GHz Zakres: (0,8 – 300) V/m
Direct measurement method PN-T-06580-3:2002 Method adapted to the regulated area | P-14 issue 16 of 24.04.2026
6 Workplace environment − electromagnetic field from radiocommunication and anti-theft systems: - hand-held and cordless radiotelephones, short-range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) - anti-theft and electronic article surveillance systems Magnetic field strength:
in the frequency range from 200 kHz to 40 MHz Zakres: (0,02 – 16,0) A/m in the frequency range from 20 MHz to 1 GHz Zakres: (0,02 – 1,2) A/m
Direct measurement method PN-T-06580-3:2002 Method adapted to the regulated area | P-14 issue 16 of 24.04.2026
7 Workplace environment − electromagnetic field from radiocommunication and anti-theft systems: - hand-held and cordless radiotelephones, short-range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) - anti-theft and electronic article surveillance systems Magnetic field strength:
in the frequency range from 800 MHz – 90 GHz (calculated)
PN-T-06580-3:2002 Method adapted to the regulated area | P-14 issue 16 of 24.04.2026
8 Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy units - physiotherapy diathermy units Electric field strength:
in the frequency range from 200 kHz to 3 GHz Zakres: (1,0 – 1000) V/m in the frequency range from 3 GHz to 90 GHz Zakres: (0,8 – 300) V/m
Direct measurement method PN-T-06580-3:2002 Method adapted to the regulated area | P-14 issue 16 of 24.04.2026
9 Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy units - physiotherapy diathermy units Magnetic field strength:
in the frequency range from 200 kHz to 40 MHz Zakres: (0,02 – 16,0) A/m in the frequency range from 20 MHz to 1 GHz Zakres: (0,02 – 1,2) A/m
Direct measurement method PN-T-06580-3:2002 Method adapted to the regulated area | P-14 issue 16 of 24.04.2026
10 Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy units - physiotherapy diathermy units Magnetic field strength:
in the frequency range from 800 MHz – 90 GHz (calculated)
PN-T-06580-3:2002 Method adapted to the regulated area | P-14 issue 16 of 24.04.2026
11 Environment - electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) Electric field strength:
in the frequency range from 200 kHz to 3 GHz Zakres: (0,8 – 1000) V/m in the frequency range from 3 GHz to 90 GHz Zakres: (0,8 – 300) V/m
Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Direct measurement method Annex to the Regulation of the Minister of Climate of 17 February 2020 (Journal of Laws 2022 item 2630)
12 Environment - electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) Magnetic field strength:
in the frequency range from 200 kHz to 40 MHz Zakres: (0,02 – 16) A/m
Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Direct measurement method Annex to the Regulation of the Minister of Climate of 17 February 2020 (Journal of Laws 2022 item 2630)
13 Environment - electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) Magnetic field strength:
in the frequency range from 10 MHz to 90 GHz (calculated)
Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Clause 3 of the Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630)
14 Workplace environment - electromagnetic field from transmitting devices of radiocommunication systems (mobile telephony base stations; broadcasting and radiocommunication systems - radio, television, etc.) Electric field strength:
in the frequency range from 100 kHz to 3 GHz Zakres: (0,8 – 1000) V/m in the frequency range from 3 GHz to 90 GHz Zakres: (0,8 – 300) V/m
Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (Journal of Laws of 2018, item 331).
Direct measurement method Principles and Methods of Assessing the Working Environment 2017, No. 2 (92), pp. 89–131
15 Workplace environment - electromagnetic field from transmitting devices of radiocommunication systems (mobile telephony base stations; broadcasting and radiocommunication systems - radio, television, etc.) Magnetic field strength:
in the frequency range from 100 kHz to 40 MHz Zakres: (0,01 – 16,0) A/m in the frequency range from 20 MHz to 800 MHz Zakres: (0,02 – 1,2) A/m
Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (Journal of Laws of 2018, item 331).
Direct measurement method Principles and Methods of Assessing the Working Environment 2017, No. 2 (92), pp. 89–131
16 Workplace environment - electromagnetic field from transmitting devices of radiocommunication systems (mobile telephony base stations; broadcasting and radiocommunication systems - radio, television, etc.) Magnetic field strength:
in the frequency range from 800 MHz to 90 GHz (calculated)
Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (Journal of Laws of 2018, item 331).
Principles and Methods of Assessing the Working Environment 2017, No. 2 (92), pp. 89–131
17 Workplace environment - electromagnetic field from magnetotherapy equipment Magnetic flux density:
in the frequency range from 20 Hz to 50 Hz Zakres: 1µT – 10,0 mT
Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the legally regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (Journal of Laws of 2018, item 331).
Direct measurement method (simplified) Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 151–180

Reference standards (6)

P-14 issue 16 of 24.04.2026
PN-T-06580-3:2002 Method adapted to the regulated area
Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 151–180
Principles and Methods of Assessing the Working Environment 2017, No. 2 (92), pp. 89–131
Clause 3 of the Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630)
Annex to the Regulation of the Minister of Climate of 17 February 2020 (Journal of Laws 2022 item 2630)

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/PL/AB%201333