🇵🇱 CENTRUM BADAŃ ŚRODOWISKA „SORBCHEM” Sp. z o.o. PL

PCA AB 1302 • Ruda Śląska, Poland • 228 methods

EnvironmentWater & wastewaterPetrochemistry & fuelsMaterials & polymers

CENTRUM BADAŃ ŚRODOWISKA „SORBCHEM” Sp. z o.o. is a laboratory accredited by PCA under number AB 1302 (Ruda Śląska, Poland). Its accreditation scope covers 228 test methods in the following areas: Environment, Water & wastewater, Petrochemistry & fuels, Materials & polymers. Test objects include: Workplace environment - air, Waste gases, Heating boilers for solid fuels with manual and automatic fuel feeding, Water, wastewater. Most frequently used techniques: Gas chromatography with flame ionization detection (GC-FID), Inductively coupled plasma optical emission spectrometry (ICP-OES), Flame atomic absorption spectrometry (FAAS).

At a glance

  • Accreditation number: PCA AB 1302
  • Methods in scope: 228
  • Types of test objects: 23
  • Techniques used: 41
  • City: Ruda Śląska, Poland
Accreditation number
AB 1302
Accreditation body
PCA
Address
LABORATORIUM, ul. Kokotek 6, 41-700 Ruda Śląska
City
Ruda Śląska, Poland

What this laboratory tests (23)

Analytical techniques used (41)

Certificate information

Issue date
30.07.2026
Issue no.
29

Accreditation scope — test methods (228)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Workplace environment - noise A-weighted equivalent sound level Maximum A-weighted sound level
Range (26 – 135) dB C-weighted peak sound pressure level Range (40 – 138) dB
Direct measurement method PN-N-01307:1994 | PN-ISO 9612:2011 excluding the method covering strategy 2 - cl. 10
2 Workplace environment - noise Noise exposure level referred to:
an 8-hour daily working time the average weekly working time (calculated)
PN-N-01307:1994 | PN-ISO 9612:2011 excluding the method covering strategy 2 - cl. 10
3 Workplace environment − emergency lighting Illuminance
Range (0,5 – 200) lx
Direct measurement method PN-EN 1838:2013-11 excluding cl. 4.2.3-4.2.5; 4.3.3-4.3.5; 4.3.9; 4.4.3-4.4.6; 4.5; 5.
4 Workplace environment − emergency lighting Ratio of minimum to maximum illuminance (calculated) PN-EN 1838:2013-11 excluding cl. 4.2.3-4.2.5; 4.3.3-4.3.5; 4.3.9; 4.4.3-4.4.6; 4.5; 5.
5 Workplace environment − emergency lighting Illuminance uniformity for the high-risk zone (calculated) PN-EN 1838:2013-11 excluding cl. 4.2.3-4.2.5; 4.3.3-4.3.5; 4.3.9; 4.4.3-4.4.6; 4.5; 5.
6 Workplace environment − emergency lighting Closing time
Range (3-90) s
Direct measurement method PN-EN 1838:2013-11 excluding cl. 4.2.3-4.2.5; 4.3.3-4.3.5; 4.3.9; 4.4.3-4.4.6; 4.5; 5.
7 General environment − noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level
Range (26 – 135) dB
Direct measurement method Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023, item 1706) excluding cl. F
8 General environment − noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023, item 1706) excluding cl. F
9 Machinery and equipment - noise Sound pressure level
weighted with the characteristic frequency weighting A Range (26 − 135) dB
Direct measurement method PN-EN ISO 3746:2011 excluding cl. 8.4 | PN-EN ISO 3746:2011/Ap1:2017-09
10 Machinery and equipment - noise Sound power level (calculated) PN-EN ISO 3746:2011 excluding cl. 8.4 | PN-EN ISO 3746:2011/Ap1:2017-09
11 Workplace environment - electric lighting Illuminance
Range (5 – 5000) lx
Direct measurement method PN-83/E-04040.03
12 Workplace environment - electric lighting Illuminance uniformity (calculated) PN-83/E-04040.03
13 Workplace environment – energy expenditure Air temperature
Range (0 – 40) °C Air flow Range (10 - 60) dm3/min
Direct measurement method Test procedure PB-51 issue 5 of 10.06.2025
14 Workplace environment – energy expenditure Energy expenditure (calculated) Test procedure PB-51 issue 5 of 10.06.2025
15 Workplace environment − moderate microclimate Air temperature
Range (10,0 – 30,0) 0C Black globe temperature Range (10,0 – 40,0) 0C Air humidity Range (20,0 – 90,0) % Air velocity Range (0,15 – 4,0) m/s
Direct measurement method PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04
16 Workplace environment − moderate microclimate PMV index, PPD index (calculated) PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04
17 Workplace environment − hot microclimate Air temperature
Range (15,0 – 60,0) 0C Natural wet bulb temperature Range (15,0 – 60,0) 0C Black globe temperature Range (15,0 – 40,0) 0C
Direct measurement method PN-EN ISO 7243:2018-01
18 Workplace environment − hot microclimate WBGT index, WBGTeff index (calculated) PN-EN ISO 7243:2018-01
19 Workplace environment − cold microclimate Air temperature
Range (-10,0 – 10,0) 0C Black globe temperature Range (-10,0 – 15,0) 0C Air humidity Range (20,0 – 90,0) % Air velocity Range (0,4 – 4,0) m/s
Direct measurement method PN-EN ISO 11079:2008
20 Workplace environment − cold microclimate IREQmin index, IREQneutral index, twc index (calculated) PN-EN ISO 11079:2008
21 Workplace environment – hand-arm vibration Frequency-weighted r.m.s. vibration acceleration
Range (0,02 – 100) m/s2
Direct measurement method PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004+A1:2015-11
22 Workplace environment – hand-arm vibration Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the vector sum of the r.m.s. frequency-corrected vibration accelerations determined for three directional components (ahwx, ahwy, ahwz), Exposure lasting 30 minutes or less, expressed as the vector sum of the r.m.s. frequency-weighted vibration accelerations determined for three directional components (ahwx, ahwy, ahwz) (calculated) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004+A1:2015-11
23 Workplace environment – whole-body vibration Frequency-weighted r.m.s. vibration acceleration
Range (0,02 – 100) m/s2
Direct measurement method PN-EN 14253+A1:2011
24 Workplace environment – whole-body vibration Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the r.m.s. frequency-corrected vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz), Exposure lasting 30 minutes or less, expressed as the r.m.s. frequency-weighted vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz) (calculated) PN-EN 14253+A1:2011
25 Workplace environment - air Sampling for the assessment of occupational exposure to:
dust agents – inhalable fraction – respirable fraction organic substances, including – inhalable fraction inorganic substances, including – inhalable fraction – thoracic fraction – respirable fraction metals and their compounds, including – inhalable fraction – respirable fraction
Personal dosimetry method PN-Z-04008-7:2002+Az1:2004
26 Workplace environment - air Sampling for occupational exposure assessment to inorganic substances Stationary method PN-Z-04008-7:2002+Az1:2004
27 Workplace environment - air Exposure index (calculated) PN-Z-04008-7:2002+Az1:2004
28 Workplace environment - air Concentration of harmful dust agents - inhalable fraction
Apatites and phosphorites Portland cement Titanium dioxide Natural graphite Synthetic graphite Kaolin Amorphous and synthetic silica Wood dusts Flour dusts Dusts not classified according to toxicity Organic dusts of animal and plant origin, excluding wood and flour dusts Calcium sulfate (VI) (gypsum) Carbon black Talc Coal (hard, brown) Calcium magnesium carbonate (dolomite) Silicon carbide, non-fibrous Range (0,19 – 20,4) mg/m3
Gravimetric method PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08
29 Workplace environment - air Concentration of dust agents harmful to health- respirable fraction
Apatites and phosphorites Portland cement Natural graphite Amorphous and synthetic silica Organic dusts of animal and plant origin, excluding wood and flour dusts Talc Coal (hard, brown) Range (0,10 – 6,2) mg/m3
Gravimetric method PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08
30 Workplace environment - air Carbon monoxide concentration
Range (2,3 – 234) mg/m3 Range (2,0 – 201) ppm
Electrochemical method Test procedure PB-01 issue 8 of 24.06.2019
31 Workplace environment - air Exposure indices (calculated) Test procedure PB-01 issue 8 of 24.06.2019
32 Workplace environment - air Crystalline silica (quartz, cristobalite) concentration/content
respirable fraction Range (0,010 – 0,4) mg/m3 Range (10,0 – 400) μg in the sample
Fourier transform infrared spectrometry (FT-IR) Principles and Methods of Assessing the Working Environment 2012, No. 4 (74), pp. 117–130
33 Workplace environment - air Ammonia concentration/ content
Range (1 – 100) mg/m3 Range (0,015 – 1,5) mg in the sample
Spectrophotometric method PN-71/Z-04041
34 Workplace environment - air Concentration/ content of nitrogen oxide and nitrogen dioxide
NO (0,09 – 10,4) mg/m3 Range (0,072 – 8,4) ppm Range (0,00045 – 0,052) mg in the sample NO2 (0,07 – 8,0) mg/m3 (0,037 – 4,2) ppm (0,00035 – 0,040) mg in the sample
Spectrophotometric method PN-Z-04009-11:2008
35 Workplace environment - air Concentration/ content of formaldehyde
Range (0,033 – 2,50) mg/m3 Range (0,0008 – 0,060) mg in the sample
High-performance liquid chromatography with spectrophotometric detection (HPLC-UV) Principles and Methods of Assessing the Working Environment 1999, No. 22, pp. 96-100
36 Workplace environment - air Concentration / content of acrylaldehyde
Range (0,005 – 2,5) mg/m3 Range (0,0021 – 1,1) ppm Range (0,00012 – 0,060) mg in the sample
High-performance liquid chromatography with spectrophotometric detection (HPLC-UV) PN-Z-04045-16:2010
37 Workplace environment - air Concentration/ content of 1-methoxypropan-2-ol
Range (4,44 – 950) mg/m3 Range (0,020 – 19) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04354:2005
38 Workplace environment - air Concentration/ content of benzene
Range (0,064 – 1,5) mg/m3 Range (0,020 – 0,46) ppm Range (0,00128 – 0,030) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04016-10:2005
39 Workplace environment - air Concentration/ content of styrene
Range (1,11 – 200) mg/m3 Range (0,005 – 19) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-86/Z-04152/02
40 Workplace environment - air Concentration/ content of methanol
Range (2,78 – 1000) mg/m3 Range (0,0125 – 5,0) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04476:2016-10
41 Workplace environment - air Concentration/ content of highly refined mineral oils excluding metalworking fluids - inhalable fraction
Range (0,4 – 32) mg/m3 Range (0,2– 3,2) mg in the sample
Fourier transform infrared spectrometry (FT-IR) PN-Z-04108-5:2006
42 Workplace environment - air Concentration/ content of ethylbenzene
Range (1,11 – 800) mg/m3 Range (0,005 – 19) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-79/Z-04081/01
43 Workplace environment - air Concentration/ content of propan-2-ol
Range (36 – 2400) mg/m3 Range (0,162 – 16,2) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) Principles and Methods of Assessing the Working Environment 2020, No. 1 (103), pp. 157–170
44 Workplace environment - air Concentration / content of acetone
Range (1,11 – 3600) mg/m3 Range (0,005 – 19) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-89/Z-04023/02
45 Workplace environment - air Concentration/ content of ethanol
Range (2,22 – 4222) mg/m3 Range (0,010 – 19) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) Test procedure PB-55 issue 1 of 10.09.2020
46 Workplace environment - air Concentration/ content of butan-1-ol
Range (1,11 – 300) mg/m3 Range (0,005 – 19) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-89/Z-04023/02
47 Workplace environment - air Concentration/ content of ethyl acetate
Range (1,11 – 3000) mg/m3 Range (0,304 – 821) ppm Range (0,005 – 19) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-89/Z-04023/02
48 Workplace environment - air Concentration/ content of n-butyl acetate
Range (1,11 – 1500) mg/m3 Range (0,005 – 19) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-89/Z-04023/02
49 Workplace environment - air Concentration/ content of xylene (mixture of isomers)
Range (1,11 – 400) mg/m3 Range (0,005 – 19) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-89/Z-04023/02
50 Workplace environment - air Concentration/ content of toluene
Range (1,11 – 400) mg/m3 Range (0,005 – 19) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-89/Z-04023/02
51 Workplace environment - air Concentration/ content of tetrachloroethene
Range (1,11 – 340) mg/m3 Range (0,161 – 49) ppm Range (0,005 – 19) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-83/Z-04118/02
52 Workplace environment - air Concentration/ content of hexane
Range (1,11 – 144) mg/m3 Range (0,005 – 19) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04136-3:2003
53 Workplace environment - air Concentration/ content of butan-2-one (methyl ethyl ketone)
Range (1,11 – 1800) mg/m3 Range (0,005 – 19) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-79/Z-04107/02
54 Workplace environment - air Concentration/ content of acetic acid
Range (0,8 – 100) mg/m3 Range (0,32 – 40) ppm Range (0,02 – 1,25) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04323:2004
55 Workplace environment - air Concentration/ content of phenol
Range (0,21 – 32) mg/m3 Range (0,005 – 0,500) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) Principles and Methods of Assessing the Working Environment 1999, No. 22, pp. 91-95
56 Workplace environment - air Concentration/ content of pentane
Range (4,44 – 6000) mg/m3 Range (0,020 – 19) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-84/Z 04135/02
57 Workplace environment - air Concentration/ content of heptane
Range (4,44 – 4000) mg/m3 Range (0,020 – 19) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-84/Z 04138/02
58 Workplace environment - air Concentration/ content of octane
Range (4,44 – 3600) mg/m3 Range (0,02 – 19) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-86/Z 04166/02
59 Workplace environment - air Concentration/ content of varnish makers' naphtha C (white spirit)
Range (4,44 – 1800) mg/m3 Range (0,02 – 19) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-81/Z-04134/03
60 Workplace environment - air Concentration/ content of extraction naphtha
Range (4,44 – 3000) mg/m3 Range (0,02 – 19) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PN-81/Z 04134/02
61 Workplace environment - air Concentration / content of metallic aluminium, aluminium powder (unstabilised) – inhalable fraction
Range (0,10 – 10,0) mg/m3 respirable fraction Range (0,11 – 10,00) mg/m3 Range (0,075 – 7,5) mg in the sample
Flame atomic absorption spectrometry (FAAS) PN-Z-04263-1:2012
62 Workplace environment - air Concentration / content of aluminium trioxide expressed as Al – inhalable fraction
Range (0,10 – 10,0) mg/m3 – respirable fraction Range (0,11 – 11,0) mg/m3 Range (0,075 – 7,5) mg in the sample
Flame atomic absorption spectrometry (FAAS) PN-Z-04263-1:2012
63 Workplace environment - air Concentration/ content of metallic nickel
Range (0,010 – 1,0) mg/m3 Range (0,0075 – 0,75) mg in the sample
Flame atomic absorption spectrometry (FAAS) PN-Z-04502:2019-10
64 Workplace environment - air Concentration / content of nickel compounds expressed as Ni
inhalable fraction Range (0,010 – 1,0) mg/m3 respirable fraction Range (0,0095 – 0,95) mg/m3 Range (0,0075 – 0,75) mg in the sample
Flame atomic absorption spectrometry (FAAS) PN-Z-04502:2019-10
65 Workplace environment - air Concentration / content of metallic chromium, chromium compounds: chromium (II), chromium (III), chromium (VI) - expressed as Cr
Range (0,017 – 3,5) mg/m3 Range (0,013– 2,5) mg in the sample
Flame atomic absorption spectrometry (FAAS) PN-Z-04434:2011
66 Workplace environment - air Concentration/ content of metallic chromium, Chromium (II) compounds expressed as chromium (II), Chromium (III) compounds expressed as chromium (III) (calculated) Test procedure PB-57 issue 1 of 16.04.2021
67 Workplace environment - air Concentration / content of zinc oxide expressed as Zn - inhalable fraction
Range (0.014 – 10,0) mg/m3 Range (0,01 – 7,5) mg in the sample
Flame atomic absorption spectrometry (FAAS) PN-87/Z-04100.03
68 Workplace environment - air Concentration/ content of manganese and its inorganic compounds expressed as Mn -inhalable fraction
Range (0,005 – 1,0) mg/m3 -respirable fraction Range (0,0047 – 0,95) mg/m3 Range (0,0037– 0,75) mg in the sample
Flame atomic absorption spectrometry (FAAS) PN-Z-04472:2015-10+Ap1:2015-12
69 Workplace environment - air Concentration/ content of copper and its inorganic compounds calculated as Cu
Range (0,005 – 1,0) mg/m3 Range (0,0037 – 0,75) mg in the sample
Flame atomic absorption spectrometry (FAAS) PN-Z-04106-3:2002
70 Workplace environment - air Concentration/ content of iron oxides calculated as Fe Iron (III) oxide Iron (II) oxide Triiron tetraoxide
inhalable fraction Range (0,02 – 8,0) mg/m3 -respirable fraction Range (0,02 – 8,0) mg/m3 Range (0,015 – 6) mg in the sample
Flame atomic absorption spectrometry (FAAS) PN-Z-04469:2015-10
71 Workplace environment - air Concentration/ content of lead and its inorganic compounds - calculated as Pb
inhalable fraction Range (0,005 – 1,0) mg/m3 Range (0,0035 – 0,7) mg in the sample
Flame atomic absorption spectrometry (FAAS) PN-Z-04487:2017-10
72 Workplace environment - air Concentration/ content of manganese and its inorganic compounds calculated as Mn
inhalable fraction Range (0,00347 – 0,69) mg/m3 Range (0,0025 – 0,50) mg in the sample respirable fraction Range (0,00316 – 0,63) mg/m3 Range (0,0025 – 0,50) mg in the sample
Inductively coupled plasma optical emission spectrometry (ICP-OES) Test procedure PB-61 issue 1 of 03.03.2025
73 Workplace environment - air Concentration/ content of iron oxides calculated as Fe Iron (III) oxide Iron (II) oxide Triiron tetraoxide
inhalable fraction Range (0,069 – 20,0) mg/m3 Range (0,050 – 10,0) mg in the sample respirable fraction Range (0,063 – 10,0) mg/m3 Range (0,050 – 10,0) mg in the sample
Inductively coupled plasma optical emission spectrometry (ICP-OES) Test procedure PB-61 issue 1 of 03.03.2025
74 Workplace environment - air Concentration/ content of silver
Range (0,00347 – 0,139) mg/m3 Range (0,0025 – 0,100) mg in the sample
Inductively coupled plasma optical emission spectrometry (ICP-OES) Test procedure PB-61 issue 1 of 03.03.2025
75 Workplace environment - air Concentration / content of metallic aluminium, aluminium powder (unstabilised) – inhalable fraction
Range (0,069 – 6,9) mg/m3 Range (0,050 – 5,0) mg in the sample respirable fraction Range (0,063 – 6,3) mg/m3 Range (0,050 – 5,0) mg in the sample
Inductively coupled plasma optical emission spectrometry (ICP-OES) Test procedure PB-61 issue 1 of 03.03.2025
76 Workplace environment - air Concentration / content of aluminium trioxide expressed as Al – inhalable fraction
Range (0,069 – 6,9) mg/m3 Range (0,050 – 5,0) mg in the sample – respirable fraction Range (0,063 – 6,3) mg/m3 Range (0,050 – 5,0) mg in the sample
Inductively coupled plasma optical emission spectrometry (ICP-OES) Test procedure PB-61 issue 1 of 03.03.2025
77 Workplace environment - air Concentration/ content of calcium oxide
inhalable fraction Range (0,053 – 12,0) mg/m3 Range (0,0378 – 3,78) mg in the sample respirable fraction Range (0,048 – 8,0) mg/m3 Range (0,0378 – 3,78) mg in the sample
Inductively coupled plasma optical emission spectrometry (ICP-OES) Test procedure PB-61 issue 1 of 03.03.2025
78 Workplace environment - air Concentration/ content of calcium hydroxide
inhalable fraction Range (0,069 – 12,0) mg/m3 Range (0,050 – 5,0) mg in the sample respirable fraction Range (0,063 – 8,0) mg/m3 Range (0,050 – 5,0) mg in the sample
Inductively coupled plasma optical emission spectrometry (ICP-OES) Test procedure PB-61 issue 1 of 03.03.2025
79 Workplace environment - air Concentration/ content of cadmium and its inorganic compounds calculated as Cd
inhalable fraction Range (0,00035 – 0,0139) mg/m3 Range (0,00025 – 0,0100) mg in the sample
Inductively coupled plasma optical emission spectrometry (ICP-OES) Test procedure PB-61 issue 1 of 03.03.2025
80 Workplace environment - air Concentration/ content of cobalt and its inorganic compounds calculated as Co
Range (0,00139 – 0,069) mg/m3 Range (0,00100 – 0,050) mg in the sample
Inductively coupled plasma optical emission spectrometry (ICP-OES) Test procedure PB-61 issue 1 of 03.03.2025
81 Workplace environment - air Concentration / content of metallic chromium, chromium compounds: chromium (II), chromium (III), chromium (VI)
calculated as Cr Range (0,0347 – 1,39) mg/m3 Range (0,0250 – 1,00) mg in the sample
Inductively coupled plasma optical emission spectrometry (ICP-OES) Test procedure PB-61 issue 1 of 03.03.2025
82 Workplace environment - air Concentration/ content of copper and its inorganic compounds calculated as Cu
Range (0,0139 – 0,69) mg/m3 Range (0,0100 – 0,50) mg in the sample
Inductively coupled plasma optical emission spectrometry (ICP-OES) Test procedure PB-61 issue 1 of 03.03.2025
83 Workplace environment - air Concentration / content of potassium hydroxide
Range (0,0139 – 2,00) mg/m3 Range (0,0100 – 1,00) mg in the sample
Inductively coupled plasma optical emission spectrometry (ICP-OES) Test procedure PB-61 issue 1 of 03.03.2025
84 Workplace environment - air Concentration / content of sodium hydroxide
Range (0,0139 – 2,00) mg/m3 Range (0,0100 – 1,00) mg in the sample
Inductively coupled plasma optical emission spectrometry (ICP-OES) Test procedure PB-61 issue 1 of 03.03.2025
85 Workplace environment - air Concentration/ content of metallic nickel
Range (0,00069 – 0,69) mg/m3 Range (0,00050 – 0,50) mg in the sample
Inductively coupled plasma optical emission spectrometry (ICP-OES) Test procedure PB-61 issue 1 of 03.03.2025
86 Workplace environment - air Concentration / content of nickel compounds expressed as Ni
inhalable fraction Range (0,00069 – 0,69) mg/m3 Range (0,00050 – 0,50) mg in the sample respirable fraction Range (0,00063 – 0,63) mg/m3 Range (0,00050 – 0,50) mg in the sample
Inductively coupled plasma optical emission spectrometry (ICP-OES) Test procedure PB-61 issue 1 of 03.03.2025
87 Workplace environment - air Concentration/ content of lead and its inorganic compounds - calculated as Pb
inhalable fraction Range (0,00347 – 0,139) mg/m3 Range (0,00250 – 0,100) mg in the sample
Inductively coupled plasma optical emission spectrometry (ICP-OES) Test procedure PB-61 issue 1 of 03.03.2025
88 Workplace environment - air Concentration/ content of tin and its inorganic compounds, except stannane – expressed as Sn
inhalable fraction Range (0,139 – 6,9) mg/m3 Range (0,100 – 5,0) mg in the sample
Inductively coupled plasma optical emission spectrometry (ICP-OES) Test procedure PB-61 issue 1 of 03.03.2025
89 Workplace environment - air Concentration/ content of titanium and its compounds – expressed as Ti
Range (0,347 – 60) mg/m3 Range (0,250 – 15,0) mg in the sample
Inductively coupled plasma optical emission spectrometry (ICP-OES) Test procedure PB-61 issue 1 of 03.03.2025
90 Workplace environment - air Concentration / content of zinc oxide expressed as Zn - inhalable fraction
Range (0,139 – 20,0) mg/m3 Range (0,100 – 10,0) mg in the sample
Inductively coupled plasma optical emission spectrometry (ICP-OES) Test procedure PB-61 issue 1 of 03.03.2025
91 Workplace environment - air Nitrogen oxide concentration / content
Range (0,125 – 14,6) mg/m3 Range (0,100 – 11,7) ppm Range (0,003 – 0,35) mg in the sample
Ion chromatography with conductometric detection (IC-CD) OSHA Method 190
92 Workplace environment - air Nitrogen dioxide concentration / content
Range (0,063 – 4,20) mg/m3 Range (0,033 – 2,2) ppm Range (0,0015 – 0,10) mg in the sample
Ion chromatography with conductometric detection (IC-CD) OSHA Method 182
93 Workplace environment - air Concentration / content of sulphur dioxide
Range (0,046 – 6,9) mg/m3 Range (0,017 – 2,6) ppm Range (0,033 – 5,0) mg in the sample
Ion chromatography with conductometric detection (IC-CD) OSHA Method 1011
94 Workplace environment - air Hydrogen sulphide concentration / content
Range (0,63 – 14,6) mg/m3 Range (0,015 – 0,35) mg in the sample
Ion chromatography with conductometric detection (IC-CD) OSHA Method 1008
95 Workplace environment - air Concentration / content of sulphuric (VI) acid – thoracic fraction
Range (0,0043 – 0,17) mg/m3 Range (0,0025 – 0,10) mg in the sample
Ion chromatography with conductometric detection (IC-CD) Principles and Methods of Assessing the Working Environment 2017, No. 2 (92), pp. 5–19
96 Workplace environment - air Hydrogen chloride concentration / content
Range (0,14 – 20,8) mg/m3 Range (0,10 – 15) mg in the sample
Ion chromatography with conductometric detection (IC-CD) NIOSH 7907 Method, Issue 1, 20 May 2014
97 Workplace environment - air Concentration / content of nitric (V) acid
Range (0,035 – 7,1) mg/m3 Range (0,025 – 5,1) mg in the sample
Ion chromatography with conductometric detection (IC-CD) NIOSH 7907 Method, Issue 1, 20 May 2014
98 Waste gases Gas volume flow rate for dynamic pressures > 10 Pa
Velocity Range (1,0 – 35) m/s
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Stagnation pressure method; Anemometric method PN-Z-04030-7:1994
99 Waste gases Sampling for determination of dust concentration
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
PN-Z-04030-7:1994
100 Waste gases Dust concentration
Range (0,001 – 10) g/m3
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Gravimetric method PN-Z-04030-7:1994
101 Waste gases Dust emission (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
PN-Z-04030-7:1994
102 Waste gases Sampling for determination of dust concentration
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
PN-EN 13284-1:2018-02
103 Waste gases Dust concentration
Range (1,0 – 50) mg/m3
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Gravimetric method PN-EN 13284-1:2018-02
104 Waste gases Dust emission (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
PN-EN 13284-1:2018-02
105 Waste gases Concentration of CO, SO2, CO2, NOX, O2
O2 (1,0 – 21) % CO2 (0,1 – 20) % CO (2,0 – 1400) mg/m3 SO2 (3,0 – 3000) mg/m3 NO (9 – 435) mg/m3 NOx (14 – 700) mg/m3
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Electrochemical method; Non-dispersive infrared absorption method (NDIR) PN-ISO 10396:2001
106 Waste gases Emission of CO, SO2, CO2, NO, NOX (NO and NO2 expressed as NO2) (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
PN-ISO 10396:2001
107 Waste gases CO concentration
Range (2,0 – 1400) mg/m3
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Non-dispersive infrared absorption method (NDIR) PN-EN 15058:2017-04
108 Waste gases CO emission (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
PN-EN 15058:2017-04
109 Waste gases NO, NOx concentration
NO (1,3 – 435) mg/m3 NOx (2,0 – 700) mg/m3
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Chemiluminescence method (CLD) PN-EN 14792:2017-04
110 Waste gases Emission of NO, NOx (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
PN-EN 14792:2017-04
111 Waste gases Sampling for determination of SO2 concentration
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
PN-EN 14791:2017-04
112 Waste gases SO2 concentration
Range (5,0 – 2000) mg/m3
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Thoron method PN-EN 14791:2017-04
113 Waste gases SO2 emission (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
PN-EN 14791:2017-04
114 Waste gases Water vapour concentration (H2O)
Range (4,0 – 40) % Range (29 – 250) g/m3
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Condensation-absorption method PN-EN 14790:2017-04
115 Waste gases Oxygen concentration
Range (3,0 – 21,0) %
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Paramagnetic method PN-EN 14789:2017-04 | PN-ISO 10396:2001
116 Waste gases Concentration of organic substances in the form of gases and vapours expressed as total gaseous organic carbon
Range (1,8 – 1000) mg/m3
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Continuous flame ionisation detection method (FID) PN-EN 12619:2013-05
117 Waste gases Emission of organic substances in gaseous and vapour form expressed as total gaseous organic carbon (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
PN-EN 12619:2013-05
118 Waste gases Sampling for determination of the concentration of individual gaseous organic compounds
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
PN-EN 13649:2005
119 Waste gases Concentration / content of individual gaseous organic compounds
acetone (0,5 – 1900) mg/m3 Range (0,005 – 19) mg in the sample butan-1-ol (0,5 – 1900) mg/m3 (0,005 – 19) mg in the sample ethanol (0,5 – 1900) mg/m3 (0,005 – 19) mg in the sample methanol (0,5 – 1900) mg/m3 (0,005 – 19) mg in the sample ethyl acetate (0,5 – 1900) mg/m3 (0,005 – 19) mg in the sample butyl acetate (0,5 – 1900) mg/m3 (0,005 – 19) mg in the sample toluene (0,5 – 1900) mg/m3 (0,005 – 19) mg in the sample xylene (mixture of isomers) (0,5 – 1900) mg/m3 (0,005 – 19) mg in the sample benzene (0,5 – 1900) mg/m3 (0,005 – 19) mg in the sample ethylbenzene (0,5 – 1900) mg/m3 (0,005 – 19) mg in the sample butan-2-one (0,5 – 1900) mg/m3 (0,005 – 19) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Gas chromatography with flame ionization detection (GC - FID) PN-EN 13649:2005
120 Waste gases Concentration / content of individual gaseous organic compounds
acetic acid Range (0,5 – 125) mg/m3 Range (0,005 – 1,25) mg in the sample pentane (0,5 – 1900) mg/m3 (0,005 – 19) mg in the sample hexane (0,5 – 1900) mg/m3 (0,005 – 19) mg in the sample heptane (0,5 – 1900) mg/m3 (0,005 – 19) mg in the sample octane (0,5 – 1900) mg/m3 (0,005 – 19) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Gas chromatography with flame ionization detection (GC - FID) PN-EN 13649:2005
121 Waste gases Sum of aromatic hydrocarbons: benzene, toluene, ethylbenzene, xylenes (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
PN-EN 13649:2005
122 Waste gases Emission of individual gaseous organic compounds (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
PN-EN 13649:2005
123 Waste gases Sampling for determination of metal concentrations: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
PN-EN 14385:2025-05
124 Waste gases Concentration / content of metals
Antimony (0,023 – 1,0) mg/m3 Range (0,025 – 2,0) mg in the sample arsenic (0,023 – 1,0) mg/m3 (0,025 – 2,0) mg in the sample chromium (0,0023 – 1,0) mg/m3 (0,0025 – 2,5) mg in the sample cadmium (0,00093 – 1,00) mg/m3 (0,001 – 2,0) mg in the sample cobalt (0,0023 – 1,0) mg/m3 (0,0025 – 2,0) mg in the sample manganese (0,0023 – 1,0) mg/m3 (0,0025 – 2,0) mg in the sample copper (0,0023 – 1,0) mg/m3 (0,0025 – 2,0) mg in the sample nickel (0,0023 – 1,0) mg/m3 (0,0025 – 2,0) mg in the sample lead (0,0046 – 1,0) mg/m3 (0,005 – 2,0) mg in the sample thallium (0,023 – 1,0) mg/m3 (0,025 – 2,0) mg in the sample vanadium (0,0023 – 1,0) mg/m3 (0,0025 – 2,0) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN 14385:2025-05
125 Waste gases Emission of metals: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
PN-EN 14385:2025-05
126 Waste gases Sampling for determination of styrene concentration
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
PN-93/Z-04152/06
127 Waste gases Concentration/ content of styrene
Range (0,5 – 1900) mg/m3 Range (0,005 – 19) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Gas chromatography with flame ionisation detection (GC FID) PN-93/Z-04152/06
128 Waste gases Emission of styrene (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
PN-93/Z-04152/06
129 Waste gases Sampling for determination of tetrachloroethene concentration
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
PN-EN 13649:2005
130 Waste gases Concentration/ content of tetrachloroethene
Range (0,5 – 1900) mg/m3 Range (0,005 –19) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005
131 Waste gases Emission of tetrachloroethene (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
PN-EN 13649:2005
132 Waste gases Sampling for the determination of the concentration of aliphatic hydrocarbons sum C5 – C12
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
PN-EN 13649:2005
133 Waste gases Concentration/ content of aliphatic hydrocarbons sum C5 – C12
Range (0,5 – 1900) mg/m3 Range (0,005 – 19) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Gas chromatography with flame ionization detection (GC-FID) PN-EN 13649:2005
134 Waste gases Emission of aliphatic hydrocarbons, sum C5 – C12 (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
PN-EN 13649:2005
135 Waste gases Sampling for determination of total mercury concentration
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
PN-EN 13211+AC:2006
136 Waste gases Total mercury emission (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
PN-EN 13211+AC:2006
137 Waste gases Sampling for determination of hydrogen chloride concentration
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
PN-EN 1911:2011
138 Waste gases Hydrogen chloride emission (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
PN-EN 1911:2011
139 Waste gases Sampling for determination of the concentration of gaseous fluorides
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
ISO 15713:2006
140 Waste gases Emission of gaseous fluorides (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
ISO 15713:2006
141 Automated Measuring Systems (AMS) AMS calibration (QAL2) for: dust, O2, CO2, CO, NOx, NO, SO2
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
PN-EN 14181:2015
142 Automated Measuring Systems (AMS) Annual surveillance test (AST) for: dust, O2, CO2, CO, NOx, NO, SO2
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
PN-EN 14181:2015
143 Automated Measuring Systems (AMS) Dust concentration
Range (0,001 – 10 ) g/m3
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Gravimetric method PN-Z-04030-7:1994
144 Automated Measuring Systems (AMS) Dust concentration
Range (1 – 50) mg/m3
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Gravimetric method PN-EN 13284-1:2018-02
145 Automated Measuring Systems (AMS) Oxygen concentration
Range (3,0 – 21,0) %
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Paramagnetic method PN-EN 14789:2017-04
146 Automated Measuring Systems (AMS) CO2 concentration
Range (0,1 – 20,0) %
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Non-dispersive infrared absorption method (NDIR) PN-ISO 10396:2001
147 Automated Measuring Systems (AMS) CO concentration
Range (2,0 – 1400) mg/m3
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Non-dispersive infrared absorption method (NDIR) PN-EN 15058:2017-04
148 Automated Measuring Systems (AMS) NO, NOx concentration
NO (1,3 – 435) mg/m3 NOx (2,0 – 700) mg/m3
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Chemiluminescence method (CLD) PN-EN 14792:2017-04
149 Automated Measuring Systems (AMS) SO2 concentration
Range (5 – 2000) mg/m3
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Thoron method PN-EN 14791:2017-04
150 Automated Measuring Systems (AMS) Water vapour concentration (H2O)
Range (4,0 – 40) % Range (29 – 250) g/m3
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law.
Condensation-absorption method PN-EN 14790:2017-04
151 Waste gases Dust sampling for determination of the fraction composition PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02
152 Waste gases Emission of the dust fraction (calculated) PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02
153 Waste gases Sampling for determination of formaldehyde concentration Aspiration method using absorbing solutions Test procedure PB-14 issue 10 of 18.09.2019
154 Waste gases Concentration/ content of formaldehyde
Range (0,2 – 100) mg/m3 Range (0,0005 – 0,02) mg in the sample
Spectrophotometric method Test procedure PB-14 issue 10 of 18.09.2019
155 Waste gases Formaldehyde emission (calculated) Test procedure PB-14 issue 10 of 18.09.2019
156 Waste gases Sampling for determination of phenol concentration Aspiration method using absorbing solutions Test procedure PB-13 issue 10 of 18.09.2019
157 Waste gases Concentration/ content of phenol
Range (0,1 – 100) mg/m3 Range (0,005 – 19) mg in the sample
Spectrophotometric method Test procedure PB-13 issue 10 of 18.09.2019
158 Waste gases Phenol emission (calculated) Test procedure PB-13 issue 10 of 18.09.2019
159 Waste gases Sampling for determination of ammonia concentration Aspiration method using absorbing solutions PN-EN ISO 21877:2020-03
160 Waste gases Ammonia concentration/ content
Range (0,17 – 100) mg/m3 Range (0,005 – 2) mg in the sample
Spectrophotometric method PN-EN ISO 21877:2020-03
161 Waste gases Ammonia emission (calculated) PN-EN ISO 21877:2020-03
162 Waste gases Sampling for determination of metal concentrations: Fe, Zn PN-EN 14385:2025-05
163 Waste gases Emission of metals: Fe, Zn (calculated) PN-EN 14385:2025-05
164 Waste gases Concentration / content of metals
zinc (0,0046 – 5,0) mg/m3 Range (0,005 – 10,0) mg in sample iron (0,023 – 5,00) mg/m3 (0,025 – 10,0) mg in the sample
Inductively coupled plasma optical emission spectrometry (ICP-OES) Test procedure PB 58 issue 1 of 16.04.2021
165 Waste gases Sampling for determination of formaldehyde concentration Test procedure PB 52 issue 3 of 28.08.2019
166 Waste gases Concentration/ content of formaldehyde
Range (0,08 – 60) mg/m3 Range (0,0008 – 0,06) mg in the sample
High-performance liquid chromatography with spectrophotometric detection (HPLC-UV) Test procedure PB 52 issue 3 of 28.08.2019
167 Waste gases Formaldehyde emission (calculated) Test procedure PB 52 issue 3 of 28.08.2019
168 Waste gases Sampling for the determination of acrylaldehyde concentration Test procedure PB 54 issue 1 of 15.05.2020
169 Waste gases Concentration / content of acrylaldehyde
Range (0,012 – 60) mg/m3 Range (0,00012 – 0,060) mg in the sample
High-performance liquid chromatography with spectrophotometric detection (HPLC-UV) Test procedure PB 54 issue 1 of 15.05.2020
170 Waste gases Emission of acrylaldehyde (calculated) Test procedure PB 54 issue 1 of 15.05.2020
171 Dust samples Content of dust fractions (particle size distribution), including PM2,5 and PM10
Range (0,6 – 1200) μm Range (0 – 100) %
Electrical sensing zone method ISO 13319-1:2021
172 Water, wastewater Mineral oil index (petroleum hydrocarbons C10-C40)
Range (0,80 – 44,0) mg/l
Gas chromatography with flame ionization detection (GC - FID) PN-EN ISO 9377-2:2003
173 Water, wastewater pH
range (2,0 – 10,0)
Potentiometric method PN-EN ISO 10523:2012
174 Water, wastewater Electrical conductivity
Range (147 – 1600) μS/cm
Conductometric method PN-EN 27888:1999
175 Water, wastewater Chemical oxygen demand
COD-Cr Range (10,0 – 2 000) mg/l O2
Spectrophotometric method PN-ISO 15705:2005
176 Water, wastewater Biochemical oxygen demand
BOD5 Range (0,50 – 6,0) mg/l O2
Titrimetric method; Electrochemical method PN-EN 1899-2:2002
177 Water, wastewater Biochemical oxygen demand
BOD5 Range (3,0 – 2000) mg/l O2
Titrimetric method; Electrochemical method PN-EN ISO 5815-1:2019-12
178 Water, wastewater Total phosphorus concentration
Range (0,050 – 40,0) mg/l
Spectrophotometric method PN-EN ISO 6878:2006 cl. 8 +Ap1:2010 + Ap2:2010
179 Water, wastewater Phosphate concentration
Range (0,050 – 40,0) mg/l
Spectrophotometric method PN-EN ISO 6878:2006 cl. 4 +Ap1:2010 + Ap2:2010
180 Water, wastewater Total suspended solids (TSS)
Range (5,0 – 1000) mg/l
Gravimetric method PN-EN 872:2007 + Ap1:2007
181 Water, wastewater Metal concentrations
zinc (0,005 – 10) mg/l cadmium (0,010 – 10) mg/l copper (0,025 – 25) mg/l nickel (0,025 – 25) mg/l lead (0,05 – 50) mg/l
Flame atomic absorption spectrometry (FAAS) PN-ISO 8288:2002 Method A IR-106 issue 1 of 05.11.2018 cl. 3.1.4
182 Water, wastewater Iron concentration
Range (0,05 – 50) mg/l
Flame atomic absorption spectrometry (FAAS) Test procedure PB-37 issue 5 of 24.06.2019
183 Water, wastewater Total chromium concentration
Range (0,05 – 8,0) mg/l
Flame atomic absorption spectrometry (FAAS) PN-EN 1233:2000 cl. 3
184 Water, wastewater Sulfate concentration
Range (10 – 1000) mg/l
Gravimetric method PN-ISO 9280:2002
185 Water, wastewater Ammonium nitrogen concentration
Range (0,10 – 160) mg/l
Spectrophotometric method PN-ISO 7150-1:2002
186 Water, wastewater Nitrite nitrogen concentration
Range (0,030 – 10) mg/l Nitrite concentration Range (0,098 – 33) mg/l
Spectrophotometric method PN-EN 26777:1999
187 Water, wastewater Nitrate nitrogen concentration
Range (0,40 – 100) mg/l Nitrate concentration Range (1,77 – 443) mg/l
Spectrophotometric method PN-82/C-04576/08
188 Water, wastewater Dissolved solids concentration
Range (10,0 – 2500) mg/l
Gravimetric method Test procedure PB-23 issue 7 of 24.06.2019
189 Water, wastewater Metal concentrations
chromium (0,0125 – 5,0) mg/l zinc (0,25 – 10) mg/l aluminium (0,050 – 10) mg/l cadmium (0,0050 – 1,0) mg/l manganese (0,025 – 5,0) mg/l copper (0,0125 – 5,0) mg/l nickel (0,0125 – 5,0) mg/l lead (0,025 – 5,0) mg/l iron (0,050 – 10) mg/l
Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN ISO 11885:2009
190 Wastewater Sampling for chemical testing and physical properties
Temperature Range (0,0 – 50,0) oC
Manual method PN-ISO 5667-10:2021-11 test procedure PB-20 issue 8 of 01.03.2022
191 Wastewater Kjeldahl nitrogen concentration
Range (3,0 – 1000) mg/l
Titrimetric method PN-EN 25663:2001
192 Wastewater Total nitrogen concentration (calculated) Test procedure PB–22 issue 6 of 24.06.2019
193 Wastewater Chloride concentration
Range (5,0 – 1000) mg/l
Titrimetric method PN-ISO 9297:1994
194 Water Chloride concentration
Range (5,0 – 400) mg/l
Titrimetric method PN-ISO 9297:1994
195 Soil pH - in KCl
Range (2,0 – 10,0)
Potentiometric method PN-EN ISO 10390:2022-09
196 Soil Dry matter content
Range (50,0 – 99,0) %
Gravimetric method PN-ISO 11465:2026-03
197 Soil Water content
Range (1,0 – 50,0) %
Gravimetric method PN-ISO 11465:2026-03
198 Soil, ground Sampling for physical and chemical testing PN-ISO 10381-4:2007 | PN-ISO 10381-5:2009
199 Soil, ground Metal content
arsenic (8,3 – 500) mg/kg barium (16,7 – 5000) mg/kg chromium (3,3 – 2000) mg/kg tin (8,3 – 500) mg/kg zinc (3,3 – 5000) mg/kg cadmium (0,83 – 50) mg/kg cobalt (1,7 – 500) mg/kg copper (3,3 – 2000) mg/kg molybdenum (3,3 – 500) mg/kg nickel (3,3 – 1000) mg/kg lead (8,3 – 1000) mg/kg
Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-ISO 11466:2002 | PN-EN ISO 11885:2009
200 Soil, ground Mercury concentration and content
Range (0,20 – 100) mg/kg
Cold vapour atomic absorption spectrometry (CVAAS) PN-ISO 16772:2009
201 Soil, ground Sum of hydrocarbons C6 - C12 (petrol fraction components)
Range (1,0 – 1000) mg/kg
Headspace gas chromatography with flame ionization detection (HS-GC-FID) Test procedure PB-59 issue 1 of 01.03.2022
202 Soil, ground Sum of hydrocarbons C12 – C35 (oil fraction components)
Range (30 – 5000) mg/kg
Gas chromatography with flame ionization detection (GC-FID) Test procedure PB-60 issue 1 of 01.03.2022
203 Soil, ground Aromatic hydrocarbon content
benzene (0,10 – 250) mg/kg ethylbenzene (0,10 – 250) mg/kg toluene (0,10 – 250) mg/kg xylenes (m,p,o) (0,10 – 250) mg/kg styrene (0,10 – 250) mg/kg
Headspace gas chromatography with flame ionization detection (HS-GC-FID) PN-EN ISO 22155:2016-07
204 Soil, ground Content of polycyclic aromatic hydrocarbons PAH
naphthalene (0,020 – 100) mg/kg anthracene (0,020 – 100) mg/kg chrysene (0,020 – 100) mg/kg benzo(a)anthracene Range (0,020 – 100) mg/kg dibenzo(ah)anthracene (0,020 – 100) mg/kg benzo(a)pyrene (0,020 – 100) mg/kg benzo(b)fluoranthene (0,020 – 100) mg/kg benzo(k)fluoranthene (0,020 – 100) mg/kg benzo(ghi)perylene (0,020 – 100) mg/kg indeno (1,2,3,c,d)pyrene (0,020 – 100) mg/kg
High-performance liquid chromatography with fluorescence detection (HPLC-FLD) PN-ISO 13877:2004
205 WasteO) code: 10 01 01 20 01 99
O) waste codes according to the Regulation of the Minister of Climate on the waste catalogue
Moisture content
Range (0,20 – 42,0) %
Gravimetric method PN-93/Z-15008/02
206 WasteO) code: 10 01 01 20 01 99
O) waste codes according to the Regulation of the Minister of Climate on the waste catalogue
Combustible matter content
Range (1,00 – 80,00) %
Gravimetric method PN-93/Z-15008/03
207 WasteO) code: 10 01 01 20 01 99
O) waste codes according to the Regulation of the Minister of Climate on the waste catalogue
Content of non-combustible parts (calculated) PN-93/Z-15008/03
208 WasteO) code: 10 01 01 20 01 99
O) waste codes according to the Regulation of the Minister of Climate on the waste catalogue
Metal content
Al (10000 – 1000000) mg/kg Cd (4 – 10000) mg/kg Co (40 – 10000) mg/kg Cr (50 – 100000) mg/kg Cu (140 – 1000000) mg/kg Fe (5000 – 1000000) mg/kg Mn (200 – 100000) mg/kg Ni (75 – 100000) mg/kg Pb (40 – 10000) mg/kg Ti (5000 – 100000) mg/kg Zn (150 – 1000000) mg/kg
Inductively coupled plasma optical emission spectrometry (ICP-OES) Test procedure PB–53 issue 2 of 07.07.2020
209 Heating boilers for solid fuels with manual and automatic fuel feeding Heat output
Range (0 – 500) kW Outlet water temperature Return water temperature Ambient temperature Range (10 – 100 ) °C Water volume flow Range (0,1 – 20,0 m3/h) Fuel mass flow Range (0,5 – 100 kg/h) Exhaust flue gas temperature Range ( 50 – 300 ) °C Flue gas pressure Range ( -150 – 50 ) hPa
Direct method; Resistance method; Ultrasonic method; Gravimetric method; Resistance method; Piezoresistive method PN-EN 303-5:2021-09 cl. 5.2 | PN-EN 303-5:2021-09 cl. 5.7 | PN-EN 303-5:2021-09 cl. 5.8 | PN-EN 303-5 +A1:2023-05 cl. 5.2 | PN-EN 303-5 +A1:2023-05 cl. 5.7 | PN-EN 303-5 +A1:2023-05 cl. 5.8 | EN 303-5:2021+A1:2022 cl. 5.2 | EN 303-5:2021+A1:2022 cl. 5.7 | EN 303-5:2021+A1:2022 cl. 5.8
210 Heating boilers for solid fuels with manual and automatic fuel feeding Concentration of oxygen, carbon dioxide, carbon monoxide, nitrogen oxides, sulphur dioxide, volatile organic compounds
O2 (1 – 21) % CO2 (0,1 – 20) % CO (3 – 1400) mg/m3 SO2 (19 – 3000) mg/m3 NO (9,0 – 435) mg/m3 NOX (14,0 – 700) mg/m3 OGC (1,8 – 1000) mg/m3 Dust concentration in flue gases Range (1,0 – 100) mg/m3
Electrochemical method - O2 (3,0 – 21,0) %; Paramagnetic method; NDIR method; Chemiluminescence method; Continuous flame ionisation detection method (FID); Gravimetric method PN-EN 303-5:2021-09 cl. 5.2 | PN-EN 303-5:2021-09 cl. 5.7 | PN-EN 303-5:2021-09 cl. 5.8 | PN-EN 303-5 +A1:2023-05 cl. 5.2 | PN-EN 303-5 +A1:2023-05 cl. 5.7 | PN-EN 303-5 +A1:2023-05 cl. 5.8 | EN 303-5:2021+A1:2022 cl. 5.2 | EN 303-5:2021+A1:2022 cl. 5.7 | EN 303-5:2021+A1:2022 cl. 5.8
211 Heating boilers for solid fuels with manual and automatic fuel feeding Emission of oxygen, carbon dioxide, carbon monoxide, nitrogen oxides, sulphur dioxide, volatile organic compounds
O2 (1– 21) % CO2 (0,1 – 20) % CO (3 – 1400) mg/m3 SO2 (19 – 3000) mg/m3 NO (9,0 – 435) mg/m3 NOX (14,0 – 700) mg/m3 OGC (1,8 – 1000) mg/m3 Dust concentration in flue gases Range (1,0 – 100) mg/m3
Electrochemical method - O2 (3,0 – 21,0) %; Paramagnetic method; NDIR method; Chemiluminescence method; Continuous flame ionisation detection method (FID); Gravimetric method PN-EN 303-5:2021-09 cl. 5.2 | PN-EN 303-5:2021-09 cl. 5.8 | PN-EN 303-5:2021-09 cl. 5.9.4 | PN-EN 303-5 +A1:2023-05 cl. 5.2 | PN-EN 303-5 +A1:2023-05 cl. 5.8 | PN-EN 303-5 +A1:2023-05 cl. 5.9.4 | EN 303-5:2021+A1:2022 cl. 5.2 | EN 303-5:2021+A1:2022 cl. 5.8 | EN 303-5:2021+A1:2022 cl. 5.9.4
212 Heating boilers for solid fuels with manual and automatic fuel feeding Nominal heat output
Range (0 – 500) kW
Direct method PN-EN 303-5:2021-09 cl. 5.7.2 | PN-EN 303-5 +A1:2023-05 cl. 5.7.2 | EN 303-5:2021+A1:2022 cl. 5.7.2
213 Heating boilers for solid fuels with manual and automatic fuel feeding Minimum heat output
Range (0 – 500) kW
Direct method PN-EN 303-5:2021-09 cl. 5.7.3 | PN-EN 303-5 +A1:2023-05 cl. 5.7.3 | EN 303-5:2021+A1:2022 cl. 5.7.3
214 Heating boilers for solid fuels with manual and automatic fuel feeding Thermal efficiency Direct method (calculated) PN-EN 303-5:2021-09 cl. 5.7.6 | PN-EN 303-5:2021-09 cl. 5.9.3.2 | PN-EN 303-5 +A1:2023-05 cl. 5.7.6 | PN-EN 303-5 +A1:2023-05 cl. 5.9.3.2 | EN 303-5:2021+A1:2022 cl. 5.7.6 | EN 303-5:2021+A1:2022 cl. 5.9.3.2
215 Heating boilers for solid fuels with manual and automatic fuel feeding Thermal efficiency Indirect method (calculated) PN-EN 303-5:2021-09 cl. 5.9.3.3 | PN-EN 303-5 +A1:2023-05 cl. 5.9.3.3 | EN 303-5:2021+A1:2022 cl. 5.9.3.3
216 Heating boilers for solid fuels with manual and automatic fuel feeding Auxiliary electrical energy consumption
Range (1 – 4000) W
Method: power transducer PN-EN 303-5:2021-09 cl. 5.7.7 | PN-EN 303-5 +A1:2023-05 cl. 5.7.7 | EN 303-5:2021+A1:2022 cl. 5.7.7
217 Heating boilers for solid fuels with manual and automatic fuel feeding Useful efficiency nGCV (calculated) PN-EN 303-5:2021-09 cl. 5.9.3.4 | PN-EN 303-5 +A1:2023-05 cl. 5.9.3.4 | EN 303-5:2021+A1:2022 cl. 5.9.3.4
218 Heating boilers for solid fuels with manual and automatic fuel feeding Seasonal space heating energy efficiency ns (calculated) PN-EN 303-5:2021-09 cl. 5.9.3.5 | PN-EN 303-5 +A1:2023-05 cl. 5.9.3.5 | EN 303-5:2021+A1:2022 cl. 5.9.3.5
219 Heating boilers for solid fuels with manual and automatic fuel feeding Energy efficiency index EEI (calculated) PN-EN 303-5:2021-09 cl. 5.9.3.6 | PN-EN 303-5 +A1:2023-05 cl. 5.9.3.6 | EN 303-5:2021+A1:2022 cl. 5.9.3.6
220 Heating boilers for solid fuels with manual and automatic fuel feeding Seasonal space heating emissions Es (calculated) PN-EN 303-5:2021-09 cl. 5.9.4.4 | PN-EN 303-5 +A1:2023-05 cl. 5.9.4.4 | EN 303-5:2021+A1:2022 cl. 5.9.4.4
221 Heating boilers for solid fuels with manual and automatic fuel feeding Surface temperature
Range (15 – 150) °C
Resistance method PN-EN 303-5:2021-09 cl. 5.11 | PN-EN 303-5 +A1:2023-05 cl. 5.11 | EN 303-5:2021+A1:2022 cl. 5.11
222 Heating boilers for solid fuels with manual and automatic fuel feeding Handle temperature
Range (0 – 150) °C
Resistance method PN-EN 303-5:2021-09 cl. 5.11 | PN-EN 303-5 +A1:2023-05 cl. 5.11 | EN 303-5:2021+A1:2022 cl. 5.11
223 Heating boilers for solid fuels with manual and automatic fuel feeding Operation of the temperature controller
outlet water temperature Range (60 – 110) °C
Resistance method PN-EN 303-5:2021-09 cl. 5.13 | PN-EN 303-5 +A1:2023-05 cl. 5.13 | EN 303-5:2021+A1:2022 cl. 5.13
224 Heating boilers for solid fuels with manual and automatic fuel feeding Operation of the safety temperature limiter
outlet water temperature Range (60 – 110) °C Carbon monoxide content CO (0,4 – 5,0) %
Resistance method; NDIR method PN-EN 303-5:2021-09 cl. 5.13 | PN-EN 303-5 +A1:2023-05 cl. 5.13 | EN 303-5:2021+A1:2022 cl. 5.13
225 Heating boilers for solid fuels with manual and automatic fuel feeding Operation of quick-release systems:
power failure heat dissipation failure outlet water temperature Range (60 – 110) °C Carbon monoxide content CO (0,4 – 5,0) %
Resistance method; NDIR method PN-EN 303-5:2021-09 cl. 5.14 | PN-EN 303-5 +A1:2023-05 cl. 5.14 | EN 303-5:2021+A1:2022 cl. 5.14
226 Heating boilers for solid fuels with manual and automatic fuel feeding Test under conditions of blocked fuel supply
outlet water temperature Range (60 – 110) °C Carbon monoxide content CO (0,4 – 5,0) %
Resistance method; NDIR method PN-EN 303-5:2021-09 cl. 5.16.2 | PN-EN 303-5 +A1:2023-05 cl. 5.16.2 | EN 303-5:2021+A1:2022 cl. 5.16.2
227 Heating boilers for solid fuels with manual and automatic fuel feeding Safety test in the event of air supply failure. Combustion air fan failure, air supply system failure
Carbon monoxide content CO (0,4 – 5,0) %
NDIR method PN-EN 303-5:2021-09 cl. 5.16.3 | PN-EN 303-5 +A1:2023-05 cl. 5.16.3 | EN 303-5:2021+A1:2022 cl. 5.16.3
228 Heating boilers for solid fuels with manual and automatic fuel feeding Safety test with regard to heat conduction
temperature Range (15 – 150) °C
Resistance method PN-EN 303-5:2021-09 cl. 5.16.4 | PN-EN 303-5 +A1:2023-05 cl. 5.16.4 | EN 303-5:2021+A1:2022 cl. 5.16.4

Reference standards (179)

EN 303-5:2021+A1:2022 cl. 5.11
EN 303-5:2021+A1:2022 cl. 5.13
EN 303-5:2021+A1:2022 cl. 5.14
EN 303-5:2021+A1:2022 cl. 5.16.2
EN 303-5:2021+A1:2022 cl. 5.16.3
EN 303-5:2021+A1:2022 cl. 5.16.4
EN 303-5:2021+A1:2022 cl. 5.2
EN 303-5:2021+A1:2022 cl. 5.7
EN 303-5:2021+A1:2022 cl. 5.7.2
EN 303-5:2021+A1:2022 cl. 5.7.3
EN 303-5:2021+A1:2022 cl. 5.7.6
EN 303-5:2021+A1:2022 cl. 5.7.7
EN 303-5:2021+A1:2022 cl. 5.8
EN 303-5:2021+A1:2022 cl. 5.9.3.2
EN 303-5:2021+A1:2022 cl. 5.9.3.3
EN 303-5:2021+A1:2022 cl. 5.9.3.4
EN 303-5:2021+A1:2022 cl. 5.9.3.5
EN 303-5:2021+A1:2022 cl. 5.9.3.6
EN 303-5:2021+A1:2022 cl. 5.9.4
EN 303-5:2021+A1:2022 cl. 5.9.4.4
ISO 13319-1:2021
ISO 15713:2006
NIOSH 7907 Method, Issue 1, 20 May 2014
OSHA Method 1008
OSHA Method 1011
OSHA Method 182
OSHA Method 190
PN-71/Z-04041
PN-79/Z-04081/01
PN-79/Z-04107/02
PN-81/Z 04134/02
PN-81/Z-04134/03
PN-82/C-04576/08
PN-83/E-04040.03
PN-83/Z-04118/02
PN-84/Z 04135/02
PN-84/Z 04138/02
PN-86/Z 04166/02
PN-86/Z-04152/02
PN-87/Z-04100.03
PN-89/Z-04023/02
PN-93/Z-04152/06
PN-93/Z-15008/02
PN-93/Z-15008/03
PN-EN 1233:2000 cl. 3
PN-EN 12619:2013-05
PN-EN 13211+AC:2006
PN-EN 13284-1:2018-02
PN-EN 13649:2005
PN-EN 14181:2015
PN-EN 14253+A1:2011
PN-EN 14385:2025-05
PN-EN 14789:2017-04
PN-EN 14790:2017-04
PN-EN 14791:2017-04
PN-EN 14792:2017-04
PN-EN 15058:2017-04
PN-EN 1838:2013-11 excluding cl. 4.2.3-4.2.5; 4.3.3-4.3.5; 4.3.9; 4.4.3-4.4.6; 4.5; 5.
PN-EN 1899-2:2002
PN-EN 1911:2011
PN-EN 25663:2001
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 303-5 +A1:2023-05 cl. 5.11
PN-EN 303-5 +A1:2023-05 cl. 5.13
PN-EN 303-5 +A1:2023-05 cl. 5.14
PN-EN 303-5 +A1:2023-05 cl. 5.16.2
PN-EN 303-5 +A1:2023-05 cl. 5.16.3
PN-EN 303-5 +A1:2023-05 cl. 5.16.4
PN-EN 303-5 +A1:2023-05 cl. 5.2
PN-EN 303-5 +A1:2023-05 cl. 5.7
PN-EN 303-5 +A1:2023-05 cl. 5.7.2
PN-EN 303-5 +A1:2023-05 cl. 5.7.3
PN-EN 303-5 +A1:2023-05 cl. 5.7.6
PN-EN 303-5 +A1:2023-05 cl. 5.7.7
PN-EN 303-5 +A1:2023-05 cl. 5.8
PN-EN 303-5 +A1:2023-05 cl. 5.9.3.2
PN-EN 303-5 +A1:2023-05 cl. 5.9.3.3
PN-EN 303-5 +A1:2023-05 cl. 5.9.3.4
PN-EN 303-5 +A1:2023-05 cl. 5.9.3.5
PN-EN 303-5 +A1:2023-05 cl. 5.9.3.6
PN-EN 303-5 +A1:2023-05 cl. 5.9.4
PN-EN 303-5 +A1:2023-05 cl. 5.9.4.4
PN-EN 303-5:2021-09 cl. 5.11
PN-EN 303-5:2021-09 cl. 5.13
PN-EN 303-5:2021-09 cl. 5.14
PN-EN 303-5:2021-09 cl. 5.16.2
PN-EN 303-5:2021-09 cl. 5.16.3
PN-EN 303-5:2021-09 cl. 5.16.4
PN-EN 303-5:2021-09 cl. 5.2
PN-EN 303-5:2021-09 cl. 5.7
PN-EN 303-5:2021-09 cl. 5.7.2
PN-EN 303-5:2021-09 cl. 5.7.3
PN-EN 303-5:2021-09 cl. 5.7.6
PN-EN 303-5:2021-09 cl. 5.7.7
PN-EN 303-5:2021-09 cl. 5.8
PN-EN 303-5:2021-09 cl. 5.9.3.2
PN-EN 303-5:2021-09 cl. 5.9.3.3
PN-EN 303-5:2021-09 cl. 5.9.3.4
PN-EN 303-5:2021-09 cl. 5.9.3.5
PN-EN 303-5:2021-09 cl. 5.9.3.6
PN-EN 303-5:2021-09 cl. 5.9.4
PN-EN 303-5:2021-09 cl. 5.9.4.4
PN-EN 872:2007 + Ap1:2007
PN-EN ISO 10390:2022-09
PN-EN ISO 10523:2012
PN-EN ISO 11079:2008
PN-EN ISO 11885:2009
PN-EN ISO 21877:2020-03
PN-EN ISO 22155:2016-07
PN-EN ISO 3746:2011 excluding cl. 8.4
PN-EN ISO 3746:2011/Ap1:2017-09
PN-EN ISO 5349-1:2004
PN-EN ISO 5349-2:2004+A1:2015-11
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6878:2006 cl. 4 +Ap1:2010 + Ap2:2010
PN-EN ISO 6878:2006 cl. 8 +Ap1:2010 + Ap2:2010
PN-EN ISO 7243:2018-01
PN-EN ISO 7730:2006
PN-EN ISO 7730:2006/Ap2:2016-04
PN-EN ISO 9377-2:2003
PN-ISO 10381-4:2007
PN-ISO 10381-5:2009
PN-ISO 10396:2001
PN-ISO 11465:2026-03
PN-ISO 11466:2002
PN-ISO 13877:2004
PN-ISO 15705:2005
PN-ISO 16772:2009
PN-ISO 5667-10:2021-11 test procedure PB-20 issue 8 of 01.03.2022
PN-ISO 7150-1:2002
PN-ISO 8288:2002 Method A IR-106 issue 1 of 05.11.2018 cl. 3.1.4
PN-ISO 9280:2002
PN-ISO 9297:1994
PN-ISO 9612:2011 excluding the method covering strategy 2 - cl. 10
PN-N-01307:1994
PN-Z-04008-7:2002+Az1:2004
PN-Z-04009-11:2008
PN-Z-04016-10:2005
PN-Z-04030-7:1994
PN-Z-04045-16:2010
PN-Z-04106-3:2002
PN-Z-04108-5:2006
PN-Z-04136-3:2003
PN-Z-04263-1:2012
PN-Z-04323:2004
PN-Z-04354:2005
PN-Z-04434:2011
PN-Z-04469:2015-10
PN-Z-04472:2015-10+Ap1:2015-12
PN-Z-04476:2016-10
PN-Z-04487:2017-10
PN-Z-04502:2019-10
PN-Z-04507:2022-05
PN-Z-04507:2022-05/Ap1:2022-08
PN-Z-04508:2022-05
PN-Z-04508:2022-05/Ap1:2022-08
Principles and Methods of Assessing the Working Environment 1999, No. 22, pp. 91-95
Principles and Methods of Assessing the Working Environment 1999, No. 22, pp. 96-100
Principles and Methods of Assessing the Working Environment 2012, No. 4 (74), pp. 117–130
Principles and Methods of Assessing the Working Environment 2017, No. 2 (92), pp. 5–19
Principles and Methods of Assessing the Working Environment 2020, No. 1 (103), pp. 157–170
Test procedure PB 52 issue 3 of 28.08.2019
Test procedure PB 54 issue 1 of 15.05.2020
Test procedure PB 58 issue 1 of 16.04.2021
Test procedure PB-01 issue 8 of 24.06.2019
Test procedure PB-13 issue 10 of 18.09.2019
Test procedure PB-14 issue 10 of 18.09.2019
Test procedure PB-23 issue 7 of 24.06.2019
Test procedure PB-37 issue 5 of 24.06.2019
Test procedure PB-51 issue 5 of 10.06.2025
Test procedure PB-55 issue 1 of 10.09.2020
Test procedure PB-57 issue 1 of 16.04.2021
Test procedure PB-59 issue 1 of 01.03.2022
Test procedure PB-60 issue 1 of 01.03.2022
Test procedure PB-61 issue 1 of 03.03.2025
Test procedure PB–22 issue 6 of 24.06.2019
Test procedure PB–53 issue 2 of 07.07.2020
Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023, item 1706) excluding cl. F

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/PL/AB%201302