🇵🇱 CENTRUM BADAŃ ŚRODOWISKA „SORBCHEM” Sp. z o.o. PL
EnvironmentWater & wastewaterPetrochemistry & fuelsMaterials & polymers
CENTRUM BADAŃ ŚRODOWISKA „SORBCHEM” Sp. z o.o. is a laboratory accredited by PCA under number AB 1302 (Ruda Śląska, Poland). Its accreditation scope covers 228 test methods in the following areas: Environment, Water & wastewater, Petrochemistry & fuels, Materials & polymers. Test objects include: Workplace environment - air, Waste gases, Heating boilers for solid fuels with manual and automatic fuel feeding, Water, wastewater. Most frequently used techniques: Gas chromatography with flame ionization detection (GC-FID), Inductively coupled plasma optical emission spectrometry (ICP-OES), Flame atomic absorption spectrometry (FAAS).
At a glance
- Accreditation number: PCA AB 1302
- Methods in scope: 228
- Types of test objects: 23
- Techniques used: 41
- City: Ruda Śląska, Poland
- Accreditation number
- AB 1302
- Accreditation body
- PCA
- Address
- LABORATORIUM, ul. Kokotek 6, 41-700 Ruda Śląska
- City
- Ruda Śląska, Poland
What this laboratory tests (23)
- Workplace environment - air — 73 methods
- Waste gases — 63 methods
- Heating boilers for solid fuels with manual and automatic fuel feeding — 20 methods
- Water, wastewater — 18 methods
- Automated Measuring Systems (AMS) — 10 methods
- Soil, ground — 7 methods
- O) waste codes according to the Regulation of the Minister of Climate on the waste catalogue — 4 methods
- WasteO) code: 10 01 01 20 01 99 — 4 methods
- Wastewater — 4 methods
- Workplace environment − emergency lighting — 4 methods
- Soil — 3 methods
- General environment − noise from installations, equipment and industrial plants — 2 methods
- Machinery and equipment - noise — 2 methods
- Workplace environment - electric lighting — 2 methods
- Workplace environment - noise — 2 methods
- and 8 more
Analytical techniques used (41)
- Gas chromatography with flame ionization detection (GC-FID) — 26 methods
- Inductively coupled plasma optical emission spectrometry (ICP-OES) — 24 methods
- Flame atomic absorption spectrometry (FAAS) — 13 methods
- Gravimetric method — 13 methods
- Direct measurement method — 12 methods
- Spectrophotometric method — 11 methods
- Ion chromatography with conductometric detection (IC-CD) — 7 methods
- High-performance liquid chromatography with spectrophotometric detection (HPLC-UV) — 4 methods
- Resistance method — 4 methods
- Aspiration method using absorbing solutions — 3 methods
- Gas chromatography with flame ionization detection (GC - FID) — 3 methods
- Non-dispersive infrared absorption method (NDIR) — 3 methods
- Resistance method; NDIR method — 3 methods
- Titrimetric method — 3 methods
- Chemiluminescence method (CLD) — 2 methods
- and 26 more
Certificate information
- Issue date
- 30.07.2026
- Issue no.
- 29
Accreditation scope — test methods (228)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Workplace environment - noise | A-weighted equivalent sound level Maximum A-weighted sound level Range (26 – 135) dB C-weighted peak sound pressure level Range (40 – 138) dB |
Direct measurement method | PN-N-01307:1994 | PN-ISO 9612:2011 excluding the method covering strategy 2 - cl. 10 | |
| 2 | Workplace environment - noise | Noise exposure level referred to: an 8-hour daily working time the average weekly working time (calculated) |
PN-N-01307:1994 | PN-ISO 9612:2011 excluding the method covering strategy 2 - cl. 10 | ||
| 3 | Workplace environment − emergency lighting | Illuminance Range (0,5 – 200) lx |
Direct measurement method | PN-EN 1838:2013-11 excluding cl. 4.2.3-4.2.5; 4.3.3-4.3.5; 4.3.9; 4.4.3-4.4.6; 4.5; 5. | |
| 4 | Workplace environment − emergency lighting | Ratio of minimum to maximum illuminance (calculated) | PN-EN 1838:2013-11 excluding cl. 4.2.3-4.2.5; 4.3.3-4.3.5; 4.3.9; 4.4.3-4.4.6; 4.5; 5. | ||
| 5 | Workplace environment − emergency lighting | Illuminance uniformity for the high-risk zone (calculated) | PN-EN 1838:2013-11 excluding cl. 4.2.3-4.2.5; 4.3.3-4.3.5; 4.3.9; 4.4.3-4.4.6; 4.5; 5. | ||
| 6 | Workplace environment − emergency lighting | Closing time Range (3-90) s |
Direct measurement method | PN-EN 1838:2013-11 excluding cl. 4.2.3-4.2.5; 4.3.3-4.3.5; 4.3.9; 4.4.3-4.4.6; 4.5; 5. | |
| 7 | General environment − noise from installations, equipment and industrial plants | A-weighted equivalent sound pressure level Range (26 – 135) dB |
Direct measurement method | Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023, item 1706) excluding cl. F | |
| 8 | General environment − noise from installations, equipment and industrial plants | A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) | Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023, item 1706) excluding cl. F | ||
| 9 | Machinery and equipment - noise | Sound pressure level weighted with the characteristic frequency weighting A Range (26 − 135) dB |
Direct measurement method | PN-EN ISO 3746:2011 excluding cl. 8.4 | PN-EN ISO 3746:2011/Ap1:2017-09 | |
| 10 | Machinery and equipment - noise | Sound power level (calculated) | PN-EN ISO 3746:2011 excluding cl. 8.4 | PN-EN ISO 3746:2011/Ap1:2017-09 | ||
| 11 | Workplace environment - electric lighting | Illuminance Range (5 – 5000) lx |
Direct measurement method | PN-83/E-04040.03 | |
| 12 | Workplace environment - electric lighting | Illuminance uniformity (calculated) | PN-83/E-04040.03 | ||
| 13 | Workplace environment – energy expenditure | Air temperature Range (0 – 40) °C Air flow Range (10 - 60) dm3/min |
Direct measurement method | Test procedure PB-51 issue 5 of 10.06.2025 | |
| 14 | Workplace environment – energy expenditure | Energy expenditure (calculated) | Test procedure PB-51 issue 5 of 10.06.2025 | ||
| 15 | Workplace environment − moderate microclimate | Air temperature Range (10,0 – 30,0) 0C Black globe temperature Range (10,0 – 40,0) 0C Air humidity Range (20,0 – 90,0) % Air velocity Range (0,15 – 4,0) m/s |
Direct measurement method | PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04 | |
| 16 | Workplace environment − moderate microclimate | PMV index, PPD index (calculated) | PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04 | ||
| 17 | Workplace environment − hot microclimate | Air temperature Range (15,0 – 60,0) 0C Natural wet bulb temperature Range (15,0 – 60,0) 0C Black globe temperature Range (15,0 – 40,0) 0C |
Direct measurement method | PN-EN ISO 7243:2018-01 | |
| 18 | Workplace environment − hot microclimate | WBGT index, WBGTeff index (calculated) | PN-EN ISO 7243:2018-01 | ||
| 19 | Workplace environment − cold microclimate | Air temperature Range (-10,0 – 10,0) 0C Black globe temperature Range (-10,0 – 15,0) 0C Air humidity Range (20,0 – 90,0) % Air velocity Range (0,4 – 4,0) m/s |
Direct measurement method | PN-EN ISO 11079:2008 | |
| 20 | Workplace environment − cold microclimate | IREQmin index, IREQneutral index, twc index (calculated) | PN-EN ISO 11079:2008 | ||
| 21 | Workplace environment – hand-arm vibration | Frequency-weighted r.m.s. vibration acceleration Range (0,02 – 100) m/s2 |
Direct measurement method | PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004+A1:2015-11 | |
| 22 | Workplace environment – hand-arm vibration | Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the vector sum of the r.m.s. frequency-corrected vibration accelerations determined for three directional components (ahwx, ahwy, ahwz), Exposure lasting 30 minutes or less, expressed as the vector sum of the r.m.s. frequency-weighted vibration accelerations determined for three directional components (ahwx, ahwy, ahwz) (calculated) | PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004+A1:2015-11 | ||
| 23 | Workplace environment – whole-body vibration | Frequency-weighted r.m.s. vibration acceleration Range (0,02 – 100) m/s2 |
Direct measurement method | PN-EN 14253+A1:2011 | |
| 24 | Workplace environment – whole-body vibration | Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the r.m.s. frequency-corrected vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz), Exposure lasting 30 minutes or less, expressed as the r.m.s. frequency-weighted vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz) (calculated) | PN-EN 14253+A1:2011 | ||
| 25 | Workplace environment - air | Sampling for the assessment of occupational exposure to: dust agents – inhalable fraction – respirable fraction organic substances, including – inhalable fraction inorganic substances, including – inhalable fraction – thoracic fraction – respirable fraction metals and their compounds, including – inhalable fraction – respirable fraction |
Personal dosimetry method | PN-Z-04008-7:2002+Az1:2004 | |
| 26 | Workplace environment - air | Sampling for occupational exposure assessment to inorganic substances | Stationary method | PN-Z-04008-7:2002+Az1:2004 | |
| 27 | Workplace environment - air | Exposure index (calculated) | PN-Z-04008-7:2002+Az1:2004 | ||
| 28 | Workplace environment - air | Concentration of harmful dust agents - inhalable fraction Apatites and phosphorites Portland cement Titanium dioxide Natural graphite Synthetic graphite Kaolin Amorphous and synthetic silica Wood dusts Flour dusts Dusts not classified according to toxicity Organic dusts of animal and plant origin, excluding wood and flour dusts Calcium sulfate (VI) (gypsum) Carbon black Talc Coal (hard, brown) Calcium magnesium carbonate (dolomite) Silicon carbide, non-fibrous Range (0,19 – 20,4) mg/m3 |
Gravimetric method | PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08 | |
| 29 | Workplace environment - air | Concentration of dust agents harmful to health- respirable fraction Apatites and phosphorites Portland cement Natural graphite Amorphous and synthetic silica Organic dusts of animal and plant origin, excluding wood and flour dusts Talc Coal (hard, brown) Range (0,10 – 6,2) mg/m3 |
Gravimetric method | PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08 | |
| 30 | Workplace environment - air | Carbon monoxide concentration Range (2,3 – 234) mg/m3 Range (2,0 – 201) ppm |
Electrochemical method | Test procedure PB-01 issue 8 of 24.06.2019 | |
| 31 | Workplace environment - air | Exposure indices (calculated) | Test procedure PB-01 issue 8 of 24.06.2019 | ||
| 32 | Workplace environment - air | Crystalline silica (quartz, cristobalite) concentration/content respirable fraction Range (0,010 – 0,4) mg/m3 Range (10,0 – 400) μg in the sample |
Fourier transform infrared spectrometry (FT-IR) | Principles and Methods of Assessing the Working Environment 2012, No. 4 (74), pp. 117–130 | |
| 33 | Workplace environment - air | Ammonia concentration/ content Range (1 – 100) mg/m3 Range (0,015 – 1,5) mg in the sample |
Spectrophotometric method | PN-71/Z-04041 | |
| 34 | Workplace environment - air | Concentration/ content of nitrogen oxide and nitrogen dioxide NO (0,09 – 10,4) mg/m3 Range (0,072 – 8,4) ppm Range (0,00045 – 0,052) mg in the sample NO2 (0,07 – 8,0) mg/m3 (0,037 – 4,2) ppm (0,00035 – 0,040) mg in the sample |
Spectrophotometric method | PN-Z-04009-11:2008 | |
| 35 | Workplace environment - air | Concentration/ content of formaldehyde Range (0,033 – 2,50) mg/m3 Range (0,0008 – 0,060) mg in the sample |
High-performance liquid chromatography with spectrophotometric detection (HPLC-UV) | Principles and Methods of Assessing the Working Environment 1999, No. 22, pp. 96-100 | |
| 36 | Workplace environment - air | Concentration / content of acrylaldehyde Range (0,005 – 2,5) mg/m3 Range (0,0021 – 1,1) ppm Range (0,00012 – 0,060) mg in the sample |
High-performance liquid chromatography with spectrophotometric detection (HPLC-UV) | PN-Z-04045-16:2010 | |
| 37 | Workplace environment - air | Concentration/ content of 1-methoxypropan-2-ol Range (4,44 – 950) mg/m3 Range (0,020 – 19) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04354:2005 | |
| 38 | Workplace environment - air | Concentration/ content of benzene Range (0,064 – 1,5) mg/m3 Range (0,020 – 0,46) ppm Range (0,00128 – 0,030) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04016-10:2005 | |
| 39 | Workplace environment - air | Concentration/ content of styrene Range (1,11 – 200) mg/m3 Range (0,005 – 19) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-86/Z-04152/02 | |
| 40 | Workplace environment - air | Concentration/ content of methanol Range (2,78 – 1000) mg/m3 Range (0,0125 – 5,0) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04476:2016-10 | |
| 41 | Workplace environment - air | Concentration/ content of highly refined mineral oils excluding metalworking fluids - inhalable fraction Range (0,4 – 32) mg/m3 Range (0,2– 3,2) mg in the sample |
Fourier transform infrared spectrometry (FT-IR) | PN-Z-04108-5:2006 | |
| 42 | Workplace environment - air | Concentration/ content of ethylbenzene Range (1,11 – 800) mg/m3 Range (0,005 – 19) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-79/Z-04081/01 | |
| 43 | Workplace environment - air | Concentration/ content of propan-2-ol Range (36 – 2400) mg/m3 Range (0,162 – 16,2) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | Principles and Methods of Assessing the Working Environment 2020, No. 1 (103), pp. 157–170 | |
| 44 | Workplace environment - air | Concentration / content of acetone Range (1,11 – 3600) mg/m3 Range (0,005 – 19) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-89/Z-04023/02 | |
| 45 | Workplace environment - air | Concentration/ content of ethanol Range (2,22 – 4222) mg/m3 Range (0,010 – 19) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | Test procedure PB-55 issue 1 of 10.09.2020 | |
| 46 | Workplace environment - air | Concentration/ content of butan-1-ol Range (1,11 – 300) mg/m3 Range (0,005 – 19) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-89/Z-04023/02 | |
| 47 | Workplace environment - air | Concentration/ content of ethyl acetate Range (1,11 – 3000) mg/m3 Range (0,304 – 821) ppm Range (0,005 – 19) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-89/Z-04023/02 | |
| 48 | Workplace environment - air | Concentration/ content of n-butyl acetate Range (1,11 – 1500) mg/m3 Range (0,005 – 19) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-89/Z-04023/02 | |
| 49 | Workplace environment - air | Concentration/ content of xylene (mixture of isomers) Range (1,11 – 400) mg/m3 Range (0,005 – 19) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-89/Z-04023/02 | |
| 50 | Workplace environment - air | Concentration/ content of toluene Range (1,11 – 400) mg/m3 Range (0,005 – 19) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-89/Z-04023/02 | |
| 51 | Workplace environment - air | Concentration/ content of tetrachloroethene Range (1,11 – 340) mg/m3 Range (0,161 – 49) ppm Range (0,005 – 19) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-83/Z-04118/02 | |
| 52 | Workplace environment - air | Concentration/ content of hexane Range (1,11 – 144) mg/m3 Range (0,005 – 19) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04136-3:2003 | |
| 53 | Workplace environment - air | Concentration/ content of butan-2-one (methyl ethyl ketone) Range (1,11 – 1800) mg/m3 Range (0,005 – 19) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-79/Z-04107/02 | |
| 54 | Workplace environment - air | Concentration/ content of acetic acid Range (0,8 – 100) mg/m3 Range (0,32 – 40) ppm Range (0,02 – 1,25) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04323:2004 | |
| 55 | Workplace environment - air | Concentration/ content of phenol Range (0,21 – 32) mg/m3 Range (0,005 – 0,500) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | Principles and Methods of Assessing the Working Environment 1999, No. 22, pp. 91-95 | |
| 56 | Workplace environment - air | Concentration/ content of pentane Range (4,44 – 6000) mg/m3 Range (0,020 – 19) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-84/Z 04135/02 | |
| 57 | Workplace environment - air | Concentration/ content of heptane Range (4,44 – 4000) mg/m3 Range (0,020 – 19) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-84/Z 04138/02 | |
| 58 | Workplace environment - air | Concentration/ content of octane Range (4,44 – 3600) mg/m3 Range (0,02 – 19) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-86/Z 04166/02 | |
| 59 | Workplace environment - air | Concentration/ content of varnish makers' naphtha C (white spirit) Range (4,44 – 1800) mg/m3 Range (0,02 – 19) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-81/Z-04134/03 | |
| 60 | Workplace environment - air | Concentration/ content of extraction naphtha Range (4,44 – 3000) mg/m3 Range (0,02 – 19) mg in the sample |
Gas chromatography with flame ionization detection (GC-FID) | PN-81/Z 04134/02 | |
| 61 | Workplace environment - air | Concentration / content of metallic aluminium, aluminium powder (unstabilised) – inhalable fraction Range (0,10 – 10,0) mg/m3 respirable fraction Range (0,11 – 10,00) mg/m3 Range (0,075 – 7,5) mg in the sample |
Flame atomic absorption spectrometry (FAAS) | PN-Z-04263-1:2012 | |
| 62 | Workplace environment - air | Concentration / content of aluminium trioxide expressed as Al – inhalable fraction Range (0,10 – 10,0) mg/m3 – respirable fraction Range (0,11 – 11,0) mg/m3 Range (0,075 – 7,5) mg in the sample |
Flame atomic absorption spectrometry (FAAS) | PN-Z-04263-1:2012 | |
| 63 | Workplace environment - air | Concentration/ content of metallic nickel Range (0,010 – 1,0) mg/m3 Range (0,0075 – 0,75) mg in the sample |
Flame atomic absorption spectrometry (FAAS) | PN-Z-04502:2019-10 | |
| 64 | Workplace environment - air | Concentration / content of nickel compounds expressed as Ni inhalable fraction Range (0,010 – 1,0) mg/m3 respirable fraction Range (0,0095 – 0,95) mg/m3 Range (0,0075 – 0,75) mg in the sample |
Flame atomic absorption spectrometry (FAAS) | PN-Z-04502:2019-10 | |
| 65 | Workplace environment - air | Concentration / content of metallic chromium, chromium compounds: chromium (II), chromium (III), chromium (VI) - expressed as Cr Range (0,017 – 3,5) mg/m3 Range (0,013– 2,5) mg in the sample |
Flame atomic absorption spectrometry (FAAS) | PN-Z-04434:2011 | |
| 66 | Workplace environment - air | Concentration/ content of metallic chromium, Chromium (II) compounds expressed as chromium (II), Chromium (III) compounds expressed as chromium (III) (calculated) | Test procedure PB-57 issue 1 of 16.04.2021 | ||
| 67 | Workplace environment - air | Concentration / content of zinc oxide expressed as Zn - inhalable fraction Range (0.014 – 10,0) mg/m3 Range (0,01 – 7,5) mg in the sample |
Flame atomic absorption spectrometry (FAAS) | PN-87/Z-04100.03 | |
| 68 | Workplace environment - air | Concentration/ content of manganese and its inorganic compounds expressed as Mn -inhalable fraction Range (0,005 – 1,0) mg/m3 -respirable fraction Range (0,0047 – 0,95) mg/m3 Range (0,0037– 0,75) mg in the sample |
Flame atomic absorption spectrometry (FAAS) | PN-Z-04472:2015-10+Ap1:2015-12 | |
| 69 | Workplace environment - air | Concentration/ content of copper and its inorganic compounds calculated as Cu Range (0,005 – 1,0) mg/m3 Range (0,0037 – 0,75) mg in the sample |
Flame atomic absorption spectrometry (FAAS) | PN-Z-04106-3:2002 | |
| 70 | Workplace environment - air | Concentration/ content of iron oxides calculated as Fe Iron (III) oxide Iron (II) oxide Triiron tetraoxide inhalable fraction Range (0,02 – 8,0) mg/m3 -respirable fraction Range (0,02 – 8,0) mg/m3 Range (0,015 – 6) mg in the sample |
Flame atomic absorption spectrometry (FAAS) | PN-Z-04469:2015-10 | |
| 71 | Workplace environment - air | Concentration/ content of lead and its inorganic compounds - calculated as Pb inhalable fraction Range (0,005 – 1,0) mg/m3 Range (0,0035 – 0,7) mg in the sample |
Flame atomic absorption spectrometry (FAAS) | PN-Z-04487:2017-10 | |
| 72 | Workplace environment - air | Concentration/ content of manganese and its inorganic compounds calculated as Mn inhalable fraction Range (0,00347 – 0,69) mg/m3 Range (0,0025 – 0,50) mg in the sample respirable fraction Range (0,00316 – 0,63) mg/m3 Range (0,0025 – 0,50) mg in the sample |
Inductively coupled plasma optical emission spectrometry (ICP-OES) | Test procedure PB-61 issue 1 of 03.03.2025 | |
| 73 | Workplace environment - air | Concentration/ content of iron oxides calculated as Fe Iron (III) oxide Iron (II) oxide Triiron tetraoxide inhalable fraction Range (0,069 – 20,0) mg/m3 Range (0,050 – 10,0) mg in the sample respirable fraction Range (0,063 – 10,0) mg/m3 Range (0,050 – 10,0) mg in the sample |
Inductively coupled plasma optical emission spectrometry (ICP-OES) | Test procedure PB-61 issue 1 of 03.03.2025 | |
| 74 | Workplace environment - air | Concentration/ content of silver Range (0,00347 – 0,139) mg/m3 Range (0,0025 – 0,100) mg in the sample |
Inductively coupled plasma optical emission spectrometry (ICP-OES) | Test procedure PB-61 issue 1 of 03.03.2025 | |
| 75 | Workplace environment - air | Concentration / content of metallic aluminium, aluminium powder (unstabilised) – inhalable fraction Range (0,069 – 6,9) mg/m3 Range (0,050 – 5,0) mg in the sample respirable fraction Range (0,063 – 6,3) mg/m3 Range (0,050 – 5,0) mg in the sample |
Inductively coupled plasma optical emission spectrometry (ICP-OES) | Test procedure PB-61 issue 1 of 03.03.2025 | |
| 76 | Workplace environment - air | Concentration / content of aluminium trioxide expressed as Al – inhalable fraction Range (0,069 – 6,9) mg/m3 Range (0,050 – 5,0) mg in the sample – respirable fraction Range (0,063 – 6,3) mg/m3 Range (0,050 – 5,0) mg in the sample |
Inductively coupled plasma optical emission spectrometry (ICP-OES) | Test procedure PB-61 issue 1 of 03.03.2025 | |
| 77 | Workplace environment - air | Concentration/ content of calcium oxide inhalable fraction Range (0,053 – 12,0) mg/m3 Range (0,0378 – 3,78) mg in the sample respirable fraction Range (0,048 – 8,0) mg/m3 Range (0,0378 – 3,78) mg in the sample |
Inductively coupled plasma optical emission spectrometry (ICP-OES) | Test procedure PB-61 issue 1 of 03.03.2025 | |
| 78 | Workplace environment - air | Concentration/ content of calcium hydroxide inhalable fraction Range (0,069 – 12,0) mg/m3 Range (0,050 – 5,0) mg in the sample respirable fraction Range (0,063 – 8,0) mg/m3 Range (0,050 – 5,0) mg in the sample |
Inductively coupled plasma optical emission spectrometry (ICP-OES) | Test procedure PB-61 issue 1 of 03.03.2025 | |
| 79 | Workplace environment - air | Concentration/ content of cadmium and its inorganic compounds calculated as Cd inhalable fraction Range (0,00035 – 0,0139) mg/m3 Range (0,00025 – 0,0100) mg in the sample |
Inductively coupled plasma optical emission spectrometry (ICP-OES) | Test procedure PB-61 issue 1 of 03.03.2025 | |
| 80 | Workplace environment - air | Concentration/ content of cobalt and its inorganic compounds calculated as Co Range (0,00139 – 0,069) mg/m3 Range (0,00100 – 0,050) mg in the sample |
Inductively coupled plasma optical emission spectrometry (ICP-OES) | Test procedure PB-61 issue 1 of 03.03.2025 | |
| 81 | Workplace environment - air | Concentration / content of metallic chromium, chromium compounds: chromium (II), chromium (III), chromium (VI) calculated as Cr Range (0,0347 – 1,39) mg/m3 Range (0,0250 – 1,00) mg in the sample |
Inductively coupled plasma optical emission spectrometry (ICP-OES) | Test procedure PB-61 issue 1 of 03.03.2025 | |
| 82 | Workplace environment - air | Concentration/ content of copper and its inorganic compounds calculated as Cu Range (0,0139 – 0,69) mg/m3 Range (0,0100 – 0,50) mg in the sample |
Inductively coupled plasma optical emission spectrometry (ICP-OES) | Test procedure PB-61 issue 1 of 03.03.2025 | |
| 83 | Workplace environment - air | Concentration / content of potassium hydroxide Range (0,0139 – 2,00) mg/m3 Range (0,0100 – 1,00) mg in the sample |
Inductively coupled plasma optical emission spectrometry (ICP-OES) | Test procedure PB-61 issue 1 of 03.03.2025 | |
| 84 | Workplace environment - air | Concentration / content of sodium hydroxide Range (0,0139 – 2,00) mg/m3 Range (0,0100 – 1,00) mg in the sample |
Inductively coupled plasma optical emission spectrometry (ICP-OES) | Test procedure PB-61 issue 1 of 03.03.2025 | |
| 85 | Workplace environment - air | Concentration/ content of metallic nickel Range (0,00069 – 0,69) mg/m3 Range (0,00050 – 0,50) mg in the sample |
Inductively coupled plasma optical emission spectrometry (ICP-OES) | Test procedure PB-61 issue 1 of 03.03.2025 | |
| 86 | Workplace environment - air | Concentration / content of nickel compounds expressed as Ni inhalable fraction Range (0,00069 – 0,69) mg/m3 Range (0,00050 – 0,50) mg in the sample respirable fraction Range (0,00063 – 0,63) mg/m3 Range (0,00050 – 0,50) mg in the sample |
Inductively coupled plasma optical emission spectrometry (ICP-OES) | Test procedure PB-61 issue 1 of 03.03.2025 | |
| 87 | Workplace environment - air | Concentration/ content of lead and its inorganic compounds - calculated as Pb inhalable fraction Range (0,00347 – 0,139) mg/m3 Range (0,00250 – 0,100) mg in the sample |
Inductively coupled plasma optical emission spectrometry (ICP-OES) | Test procedure PB-61 issue 1 of 03.03.2025 | |
| 88 | Workplace environment - air | Concentration/ content of tin and its inorganic compounds, except stannane – expressed as Sn inhalable fraction Range (0,139 – 6,9) mg/m3 Range (0,100 – 5,0) mg in the sample |
Inductively coupled plasma optical emission spectrometry (ICP-OES) | Test procedure PB-61 issue 1 of 03.03.2025 | |
| 89 | Workplace environment - air | Concentration/ content of titanium and its compounds – expressed as Ti Range (0,347 – 60) mg/m3 Range (0,250 – 15,0) mg in the sample |
Inductively coupled plasma optical emission spectrometry (ICP-OES) | Test procedure PB-61 issue 1 of 03.03.2025 | |
| 90 | Workplace environment - air | Concentration / content of zinc oxide expressed as Zn - inhalable fraction Range (0,139 – 20,0) mg/m3 Range (0,100 – 10,0) mg in the sample |
Inductively coupled plasma optical emission spectrometry (ICP-OES) | Test procedure PB-61 issue 1 of 03.03.2025 | |
| 91 | Workplace environment - air | Nitrogen oxide concentration / content Range (0,125 – 14,6) mg/m3 Range (0,100 – 11,7) ppm Range (0,003 – 0,35) mg in the sample |
Ion chromatography with conductometric detection (IC-CD) | OSHA Method 190 | |
| 92 | Workplace environment - air | Nitrogen dioxide concentration / content Range (0,063 – 4,20) mg/m3 Range (0,033 – 2,2) ppm Range (0,0015 – 0,10) mg in the sample |
Ion chromatography with conductometric detection (IC-CD) | OSHA Method 182 | |
| 93 | Workplace environment - air | Concentration / content of sulphur dioxide Range (0,046 – 6,9) mg/m3 Range (0,017 – 2,6) ppm Range (0,033 – 5,0) mg in the sample |
Ion chromatography with conductometric detection (IC-CD) | OSHA Method 1011 | |
| 94 | Workplace environment - air | Hydrogen sulphide concentration / content Range (0,63 – 14,6) mg/m3 Range (0,015 – 0,35) mg in the sample |
Ion chromatography with conductometric detection (IC-CD) | OSHA Method 1008 | |
| 95 | Workplace environment - air | Concentration / content of sulphuric (VI) acid – thoracic fraction Range (0,0043 – 0,17) mg/m3 Range (0,0025 – 0,10) mg in the sample |
Ion chromatography with conductometric detection (IC-CD) | Principles and Methods of Assessing the Working Environment 2017, No. 2 (92), pp. 5–19 | |
| 96 | Workplace environment - air | Hydrogen chloride concentration / content Range (0,14 – 20,8) mg/m3 Range (0,10 – 15) mg in the sample |
Ion chromatography with conductometric detection (IC-CD) | NIOSH 7907 Method, Issue 1, 20 May 2014 | |
| 97 | Workplace environment - air | Concentration / content of nitric (V) acid Range (0,035 – 7,1) mg/m3 Range (0,025 – 5,1) mg in the sample |
Ion chromatography with conductometric detection (IC-CD) | NIOSH 7907 Method, Issue 1, 20 May 2014 | |
| 98 | Waste gases | Gas volume flow rate for dynamic pressures > 10 Pa Velocity Range (1,0 – 35) m/s Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Stagnation pressure method; Anemometric method | PN-Z-04030-7:1994 | |
| 99 | Waste gases | Sampling for determination of dust concentration Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
PN-Z-04030-7:1994 | ||
| 100 | Waste gases | Dust concentration Range (0,001 – 10) g/m3 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Gravimetric method | PN-Z-04030-7:1994 | |
| 101 | Waste gases | Dust emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
PN-Z-04030-7:1994 | ||
| 102 | Waste gases | Sampling for determination of dust concentration Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
PN-EN 13284-1:2018-02 | ||
| 103 | Waste gases | Dust concentration Range (1,0 – 50) mg/m3 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Gravimetric method | PN-EN 13284-1:2018-02 | |
| 104 | Waste gases | Dust emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
PN-EN 13284-1:2018-02 | ||
| 105 | Waste gases | Concentration of CO, SO2, CO2, NOX, O2 O2 (1,0 – 21) % CO2 (0,1 – 20) % CO (2,0 – 1400) mg/m3 SO2 (3,0 – 3000) mg/m3 NO (9 – 435) mg/m3 NOx (14 – 700) mg/m3 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Electrochemical method; Non-dispersive infrared absorption method (NDIR) | PN-ISO 10396:2001 | |
| 106 | Waste gases | Emission of CO, SO2, CO2, NO, NOX (NO and NO2 expressed as NO2) (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
PN-ISO 10396:2001 | ||
| 107 | Waste gases | CO concentration Range (2,0 – 1400) mg/m3 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Non-dispersive infrared absorption method (NDIR) | PN-EN 15058:2017-04 | |
| 108 | Waste gases | CO emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
PN-EN 15058:2017-04 | ||
| 109 | Waste gases | NO, NOx concentration NO (1,3 – 435) mg/m3 NOx (2,0 – 700) mg/m3 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Chemiluminescence method (CLD) | PN-EN 14792:2017-04 | |
| 110 | Waste gases | Emission of NO, NOx (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
PN-EN 14792:2017-04 | ||
| 111 | Waste gases | Sampling for determination of SO2 concentration Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
PN-EN 14791:2017-04 | ||
| 112 | Waste gases | SO2 concentration Range (5,0 – 2000) mg/m3 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Thoron method | PN-EN 14791:2017-04 | |
| 113 | Waste gases | SO2 emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
PN-EN 14791:2017-04 | ||
| 114 | Waste gases | Water vapour concentration (H2O) Range (4,0 – 40) % Range (29 – 250) g/m3 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Condensation-absorption method | PN-EN 14790:2017-04 | |
| 115 | Waste gases | Oxygen concentration Range (3,0 – 21,0) % Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Paramagnetic method | PN-EN 14789:2017-04 | PN-ISO 10396:2001 | |
| 116 | Waste gases | Concentration of organic substances in the form of gases and vapours expressed as total gaseous organic carbon Range (1,8 – 1000) mg/m3 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Continuous flame ionisation detection method (FID) | PN-EN 12619:2013-05 | |
| 117 | Waste gases | Emission of organic substances in gaseous and vapour form expressed as total gaseous organic carbon (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
PN-EN 12619:2013-05 | ||
| 118 | Waste gases | Sampling for determination of the concentration of individual gaseous organic compounds Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
PN-EN 13649:2005 | ||
| 119 | Waste gases | Concentration / content of individual gaseous organic compounds acetone (0,5 – 1900) mg/m3 Range (0,005 – 19) mg in the sample butan-1-ol (0,5 – 1900) mg/m3 (0,005 – 19) mg in the sample ethanol (0,5 – 1900) mg/m3 (0,005 – 19) mg in the sample methanol (0,5 – 1900) mg/m3 (0,005 – 19) mg in the sample ethyl acetate (0,5 – 1900) mg/m3 (0,005 – 19) mg in the sample butyl acetate (0,5 – 1900) mg/m3 (0,005 – 19) mg in the sample toluene (0,5 – 1900) mg/m3 (0,005 – 19) mg in the sample xylene (mixture of isomers) (0,5 – 1900) mg/m3 (0,005 – 19) mg in the sample benzene (0,5 – 1900) mg/m3 (0,005 – 19) mg in the sample ethylbenzene (0,5 – 1900) mg/m3 (0,005 – 19) mg in the sample butan-2-one (0,5 – 1900) mg/m3 (0,005 – 19) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Gas chromatography with flame ionization detection (GC - FID) | PN-EN 13649:2005 | |
| 120 | Waste gases | Concentration / content of individual gaseous organic compounds acetic acid Range (0,5 – 125) mg/m3 Range (0,005 – 1,25) mg in the sample pentane (0,5 – 1900) mg/m3 (0,005 – 19) mg in the sample hexane (0,5 – 1900) mg/m3 (0,005 – 19) mg in the sample heptane (0,5 – 1900) mg/m3 (0,005 – 19) mg in the sample octane (0,5 – 1900) mg/m3 (0,005 – 19) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Gas chromatography with flame ionization detection (GC - FID) | PN-EN 13649:2005 | |
| 121 | Waste gases | Sum of aromatic hydrocarbons: benzene, toluene, ethylbenzene, xylenes (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
PN-EN 13649:2005 | ||
| 122 | Waste gases | Emission of individual gaseous organic compounds (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
PN-EN 13649:2005 | ||
| 123 | Waste gases | Sampling for determination of metal concentrations: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
PN-EN 14385:2025-05 | ||
| 124 | Waste gases | Concentration / content of metals Antimony (0,023 – 1,0) mg/m3 Range (0,025 – 2,0) mg in the sample arsenic (0,023 – 1,0) mg/m3 (0,025 – 2,0) mg in the sample chromium (0,0023 – 1,0) mg/m3 (0,0025 – 2,5) mg in the sample cadmium (0,00093 – 1,00) mg/m3 (0,001 – 2,0) mg in the sample cobalt (0,0023 – 1,0) mg/m3 (0,0025 – 2,0) mg in the sample manganese (0,0023 – 1,0) mg/m3 (0,0025 – 2,0) mg in the sample copper (0,0023 – 1,0) mg/m3 (0,0025 – 2,0) mg in the sample nickel (0,0023 – 1,0) mg/m3 (0,0025 – 2,0) mg in the sample lead (0,0046 – 1,0) mg/m3 (0,005 – 2,0) mg in the sample thallium (0,023 – 1,0) mg/m3 (0,025 – 2,0) mg in the sample vanadium (0,0023 – 1,0) mg/m3 (0,0025 – 2,0) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Inductively coupled plasma optical emission spectrometry (ICP-OES) | PN-EN 14385:2025-05 | |
| 125 | Waste gases | Emission of metals: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
PN-EN 14385:2025-05 | ||
| 126 | Waste gases | Sampling for determination of styrene concentration Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
PN-93/Z-04152/06 | ||
| 127 | Waste gases | Concentration/ content of styrene Range (0,5 – 1900) mg/m3 Range (0,005 – 19) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Gas chromatography with flame ionisation detection (GC FID) | PN-93/Z-04152/06 | |
| 128 | Waste gases | Emission of styrene (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
PN-93/Z-04152/06 | ||
| 129 | Waste gases | Sampling for determination of tetrachloroethene concentration Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
PN-EN 13649:2005 | ||
| 130 | Waste gases | Concentration/ content of tetrachloroethene Range (0,5 – 1900) mg/m3 Range (0,005 –19) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN 13649:2005 | |
| 131 | Waste gases | Emission of tetrachloroethene (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
PN-EN 13649:2005 | ||
| 132 | Waste gases | Sampling for the determination of the concentration of aliphatic hydrocarbons sum C5 – C12 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
PN-EN 13649:2005 | ||
| 133 | Waste gases | Concentration/ content of aliphatic hydrocarbons sum C5 – C12 Range (0,5 – 1900) mg/m3 Range (0,005 – 19) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN 13649:2005 | |
| 134 | Waste gases | Emission of aliphatic hydrocarbons, sum C5 – C12 (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
PN-EN 13649:2005 | ||
| 135 | Waste gases | Sampling for determination of total mercury concentration Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
PN-EN 13211+AC:2006 | ||
| 136 | Waste gases | Total mercury emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
PN-EN 13211+AC:2006 | ||
| 137 | Waste gases | Sampling for determination of hydrogen chloride concentration Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
PN-EN 1911:2011 | ||
| 138 | Waste gases | Hydrogen chloride emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
PN-EN 1911:2011 | ||
| 139 | Waste gases | Sampling for determination of the concentration of gaseous fluorides Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
ISO 15713:2006 | ||
| 140 | Waste gases | Emission of gaseous fluorides (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
ISO 15713:2006 | ||
| 141 | Automated Measuring Systems (AMS) | AMS calibration (QAL2) for: dust, O2, CO2, CO, NOx, NO, SO2 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
PN-EN 14181:2015 | ||
| 142 | Automated Measuring Systems (AMS) | Annual surveillance test (AST) for: dust, O2, CO2, CO, NOx, NO, SO2 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
PN-EN 14181:2015 | ||
| 143 | Automated Measuring Systems (AMS) | Dust concentration Range (0,001 – 10 ) g/m3 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Gravimetric method | PN-Z-04030-7:1994 | |
| 144 | Automated Measuring Systems (AMS) | Dust concentration Range (1 – 50) mg/m3 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Gravimetric method | PN-EN 13284-1:2018-02 | |
| 145 | Automated Measuring Systems (AMS) | Oxygen concentration Range (3,0 – 21,0) % Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Paramagnetic method | PN-EN 14789:2017-04 | |
| 146 | Automated Measuring Systems (AMS) | CO2 concentration Range (0,1 – 20,0) % Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Non-dispersive infrared absorption method (NDIR) | PN-ISO 10396:2001 | |
| 147 | Automated Measuring Systems (AMS) | CO concentration Range (2,0 – 1400) mg/m3 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Non-dispersive infrared absorption method (NDIR) | PN-EN 15058:2017-04 | |
| 148 | Automated Measuring Systems (AMS) | NO, NOx concentration NO (1,3 – 435) mg/m3 NOx (2,0 – 700) mg/m3 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Chemiluminescence method (CLD) | PN-EN 14792:2017-04 | |
| 149 | Automated Measuring Systems (AMS) | SO2 concentration Range (5 – 2000) mg/m3 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Thoron method | PN-EN 14791:2017-04 | |
| 150 | Automated Measuring Systems (AMS) | Water vapour concentration (H2O) Range (4,0 – 40) % Range (29 – 250) g/m3 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Condensation-absorption method | PN-EN 14790:2017-04 | |
| 151 | Waste gases | Dust sampling for determination of the fraction composition | PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02 | ||
| 152 | Waste gases | Emission of the dust fraction (calculated) | PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02 | ||
| 153 | Waste gases | Sampling for determination of formaldehyde concentration | Aspiration method using absorbing solutions | Test procedure PB-14 issue 10 of 18.09.2019 | |
| 154 | Waste gases | Concentration/ content of formaldehyde Range (0,2 – 100) mg/m3 Range (0,0005 – 0,02) mg in the sample |
Spectrophotometric method | Test procedure PB-14 issue 10 of 18.09.2019 | |
| 155 | Waste gases | Formaldehyde emission (calculated) | Test procedure PB-14 issue 10 of 18.09.2019 | ||
| 156 | Waste gases | Sampling for determination of phenol concentration | Aspiration method using absorbing solutions | Test procedure PB-13 issue 10 of 18.09.2019 | |
| 157 | Waste gases | Concentration/ content of phenol Range (0,1 – 100) mg/m3 Range (0,005 – 19) mg in the sample |
Spectrophotometric method | Test procedure PB-13 issue 10 of 18.09.2019 | |
| 158 | Waste gases | Phenol emission (calculated) | Test procedure PB-13 issue 10 of 18.09.2019 | ||
| 159 | Waste gases | Sampling for determination of ammonia concentration | Aspiration method using absorbing solutions | PN-EN ISO 21877:2020-03 | |
| 160 | Waste gases | Ammonia concentration/ content Range (0,17 – 100) mg/m3 Range (0,005 – 2) mg in the sample |
Spectrophotometric method | PN-EN ISO 21877:2020-03 | |
| 161 | Waste gases | Ammonia emission (calculated) | PN-EN ISO 21877:2020-03 | ||
| 162 | Waste gases | Sampling for determination of metal concentrations: Fe, Zn | PN-EN 14385:2025-05 | ||
| 163 | Waste gases | Emission of metals: Fe, Zn (calculated) | PN-EN 14385:2025-05 | ||
| 164 | Waste gases | Concentration / content of metals zinc (0,0046 – 5,0) mg/m3 Range (0,005 – 10,0) mg in sample iron (0,023 – 5,00) mg/m3 (0,025 – 10,0) mg in the sample |
Inductively coupled plasma optical emission spectrometry (ICP-OES) | Test procedure PB 58 issue 1 of 16.04.2021 | |
| 165 | Waste gases | Sampling for determination of formaldehyde concentration | Test procedure PB 52 issue 3 of 28.08.2019 | ||
| 166 | Waste gases | Concentration/ content of formaldehyde Range (0,08 – 60) mg/m3 Range (0,0008 – 0,06) mg in the sample |
High-performance liquid chromatography with spectrophotometric detection (HPLC-UV) | Test procedure PB 52 issue 3 of 28.08.2019 | |
| 167 | Waste gases | Formaldehyde emission (calculated) | Test procedure PB 52 issue 3 of 28.08.2019 | ||
| 168 | Waste gases | Sampling for the determination of acrylaldehyde concentration | Test procedure PB 54 issue 1 of 15.05.2020 | ||
| 169 | Waste gases | Concentration / content of acrylaldehyde Range (0,012 – 60) mg/m3 Range (0,00012 – 0,060) mg in the sample |
High-performance liquid chromatography with spectrophotometric detection (HPLC-UV) | Test procedure PB 54 issue 1 of 15.05.2020 | |
| 170 | Waste gases | Emission of acrylaldehyde (calculated) | Test procedure PB 54 issue 1 of 15.05.2020 | ||
| 171 | Dust samples | Content of dust fractions (particle size distribution), including PM2,5 and PM10 Range (0,6 – 1200) μm Range (0 – 100) % |
Electrical sensing zone method | ISO 13319-1:2021 | |
| 172 | Water, wastewater | Mineral oil index (petroleum hydrocarbons C10-C40) Range (0,80 – 44,0) mg/l |
Gas chromatography with flame ionization detection (GC - FID) | PN-EN ISO 9377-2:2003 | |
| 173 | Water, wastewater | pH range (2,0 – 10,0) |
Potentiometric method | PN-EN ISO 10523:2012 | |
| 174 | Water, wastewater | Electrical conductivity Range (147 – 1600) μS/cm |
Conductometric method | PN-EN 27888:1999 | |
| 175 | Water, wastewater | Chemical oxygen demand COD-Cr Range (10,0 – 2 000) mg/l O2 |
Spectrophotometric method | PN-ISO 15705:2005 | |
| 176 | Water, wastewater | Biochemical oxygen demand BOD5 Range (0,50 – 6,0) mg/l O2 |
Titrimetric method; Electrochemical method | PN-EN 1899-2:2002 | |
| 177 | Water, wastewater | Biochemical oxygen demand BOD5 Range (3,0 – 2000) mg/l O2 |
Titrimetric method; Electrochemical method | PN-EN ISO 5815-1:2019-12 | |
| 178 | Water, wastewater | Total phosphorus concentration Range (0,050 – 40,0) mg/l |
Spectrophotometric method | PN-EN ISO 6878:2006 cl. 8 +Ap1:2010 + Ap2:2010 | |
| 179 | Water, wastewater | Phosphate concentration Range (0,050 – 40,0) mg/l |
Spectrophotometric method | PN-EN ISO 6878:2006 cl. 4 +Ap1:2010 + Ap2:2010 | |
| 180 | Water, wastewater | Total suspended solids (TSS) Range (5,0 – 1000) mg/l |
Gravimetric method | PN-EN 872:2007 + Ap1:2007 | |
| 181 | Water, wastewater | Metal concentrations zinc (0,005 – 10) mg/l cadmium (0,010 – 10) mg/l copper (0,025 – 25) mg/l nickel (0,025 – 25) mg/l lead (0,05 – 50) mg/l |
Flame atomic absorption spectrometry (FAAS) | PN-ISO 8288:2002 Method A IR-106 issue 1 of 05.11.2018 cl. 3.1.4 | |
| 182 | Water, wastewater | Iron concentration Range (0,05 – 50) mg/l |
Flame atomic absorption spectrometry (FAAS) | Test procedure PB-37 issue 5 of 24.06.2019 | |
| 183 | Water, wastewater | Total chromium concentration Range (0,05 – 8,0) mg/l |
Flame atomic absorption spectrometry (FAAS) | PN-EN 1233:2000 cl. 3 | |
| 184 | Water, wastewater | Sulfate concentration Range (10 – 1000) mg/l |
Gravimetric method | PN-ISO 9280:2002 | |
| 185 | Water, wastewater | Ammonium nitrogen concentration Range (0,10 – 160) mg/l |
Spectrophotometric method | PN-ISO 7150-1:2002 | |
| 186 | Water, wastewater | Nitrite nitrogen concentration Range (0,030 – 10) mg/l Nitrite concentration Range (0,098 – 33) mg/l |
Spectrophotometric method | PN-EN 26777:1999 | |
| 187 | Water, wastewater | Nitrate nitrogen concentration Range (0,40 – 100) mg/l Nitrate concentration Range (1,77 – 443) mg/l |
Spectrophotometric method | PN-82/C-04576/08 | |
| 188 | Water, wastewater | Dissolved solids concentration Range (10,0 – 2500) mg/l |
Gravimetric method | Test procedure PB-23 issue 7 of 24.06.2019 | |
| 189 | Water, wastewater | Metal concentrations chromium (0,0125 – 5,0) mg/l zinc (0,25 – 10) mg/l aluminium (0,050 – 10) mg/l cadmium (0,0050 – 1,0) mg/l manganese (0,025 – 5,0) mg/l copper (0,0125 – 5,0) mg/l nickel (0,0125 – 5,0) mg/l lead (0,025 – 5,0) mg/l iron (0,050 – 10) mg/l |
Inductively coupled plasma optical emission spectrometry (ICP-OES) | PN-EN ISO 11885:2009 | |
| 190 | Wastewater | Sampling for chemical testing and physical properties Temperature Range (0,0 – 50,0) oC |
Manual method | PN-ISO 5667-10:2021-11 test procedure PB-20 issue 8 of 01.03.2022 | |
| 191 | Wastewater | Kjeldahl nitrogen concentration Range (3,0 – 1000) mg/l |
Titrimetric method | PN-EN 25663:2001 | |
| 192 | Wastewater | Total nitrogen concentration (calculated) | Test procedure PB–22 issue 6 of 24.06.2019 | ||
| 193 | Wastewater | Chloride concentration Range (5,0 – 1000) mg/l |
Titrimetric method | PN-ISO 9297:1994 | |
| 194 | Water | Chloride concentration Range (5,0 – 400) mg/l |
Titrimetric method | PN-ISO 9297:1994 | |
| 195 | Soil | pH - in KCl Range (2,0 – 10,0) |
Potentiometric method | PN-EN ISO 10390:2022-09 | |
| 196 | Soil | Dry matter content Range (50,0 – 99,0) % |
Gravimetric method | PN-ISO 11465:2026-03 | |
| 197 | Soil | Water content Range (1,0 – 50,0) % |
Gravimetric method | PN-ISO 11465:2026-03 | |
| 198 | Soil, ground | Sampling for physical and chemical testing | PN-ISO 10381-4:2007 | PN-ISO 10381-5:2009 | ||
| 199 | Soil, ground | Metal content arsenic (8,3 – 500) mg/kg barium (16,7 – 5000) mg/kg chromium (3,3 – 2000) mg/kg tin (8,3 – 500) mg/kg zinc (3,3 – 5000) mg/kg cadmium (0,83 – 50) mg/kg cobalt (1,7 – 500) mg/kg copper (3,3 – 2000) mg/kg molybdenum (3,3 – 500) mg/kg nickel (3,3 – 1000) mg/kg lead (8,3 – 1000) mg/kg |
Inductively coupled plasma optical emission spectrometry (ICP-OES) | PN-ISO 11466:2002 | PN-EN ISO 11885:2009 | |
| 200 | Soil, ground | Mercury concentration and content Range (0,20 – 100) mg/kg |
Cold vapour atomic absorption spectrometry (CVAAS) | PN-ISO 16772:2009 | |
| 201 | Soil, ground | Sum of hydrocarbons C6 - C12 (petrol fraction components) Range (1,0 – 1000) mg/kg |
Headspace gas chromatography with flame ionization detection (HS-GC-FID) | Test procedure PB-59 issue 1 of 01.03.2022 | |
| 202 | Soil, ground | Sum of hydrocarbons C12 – C35 (oil fraction components) Range (30 – 5000) mg/kg |
Gas chromatography with flame ionization detection (GC-FID) | Test procedure PB-60 issue 1 of 01.03.2022 | |
| 203 | Soil, ground | Aromatic hydrocarbon content benzene (0,10 – 250) mg/kg ethylbenzene (0,10 – 250) mg/kg toluene (0,10 – 250) mg/kg xylenes (m,p,o) (0,10 – 250) mg/kg styrene (0,10 – 250) mg/kg |
Headspace gas chromatography with flame ionization detection (HS-GC-FID) | PN-EN ISO 22155:2016-07 | |
| 204 | Soil, ground | Content of polycyclic aromatic hydrocarbons PAH naphthalene (0,020 – 100) mg/kg anthracene (0,020 – 100) mg/kg chrysene (0,020 – 100) mg/kg benzo(a)anthracene Range (0,020 – 100) mg/kg dibenzo(ah)anthracene (0,020 – 100) mg/kg benzo(a)pyrene (0,020 – 100) mg/kg benzo(b)fluoranthene (0,020 – 100) mg/kg benzo(k)fluoranthene (0,020 – 100) mg/kg benzo(ghi)perylene (0,020 – 100) mg/kg indeno (1,2,3,c,d)pyrene (0,020 – 100) mg/kg |
High-performance liquid chromatography with fluorescence detection (HPLC-FLD) | PN-ISO 13877:2004 | |
| 205 | WasteO) code: 10 01 01 20 01 99 O) waste codes according to the Regulation of the Minister of Climate on the waste catalogue |
Moisture content Range (0,20 – 42,0) % |
Gravimetric method | PN-93/Z-15008/02 | |
| 206 | WasteO) code: 10 01 01 20 01 99 O) waste codes according to the Regulation of the Minister of Climate on the waste catalogue |
Combustible matter content Range (1,00 – 80,00) % |
Gravimetric method | PN-93/Z-15008/03 | |
| 207 | WasteO) code: 10 01 01 20 01 99 O) waste codes according to the Regulation of the Minister of Climate on the waste catalogue |
Content of non-combustible parts (calculated) | PN-93/Z-15008/03 | ||
| 208 | WasteO) code: 10 01 01 20 01 99 O) waste codes according to the Regulation of the Minister of Climate on the waste catalogue |
Metal content Al (10000 – 1000000) mg/kg Cd (4 – 10000) mg/kg Co (40 – 10000) mg/kg Cr (50 – 100000) mg/kg Cu (140 – 1000000) mg/kg Fe (5000 – 1000000) mg/kg Mn (200 – 100000) mg/kg Ni (75 – 100000) mg/kg Pb (40 – 10000) mg/kg Ti (5000 – 100000) mg/kg Zn (150 – 1000000) mg/kg |
Inductively coupled plasma optical emission spectrometry (ICP-OES) | Test procedure PB–53 issue 2 of 07.07.2020 | |
| 209 | Heating boilers for solid fuels with manual and automatic fuel feeding | Heat output Range (0 – 500) kW Outlet water temperature Return water temperature Ambient temperature Range (10 – 100 ) °C Water volume flow Range (0,1 – 20,0 m3/h) Fuel mass flow Range (0,5 – 100 kg/h) Exhaust flue gas temperature Range ( 50 – 300 ) °C Flue gas pressure Range ( -150 – 50 ) hPa |
Direct method; Resistance method; Ultrasonic method; Gravimetric method; Resistance method; Piezoresistive method | PN-EN 303-5:2021-09 cl. 5.2 | PN-EN 303-5:2021-09 cl. 5.7 | PN-EN 303-5:2021-09 cl. 5.8 | PN-EN 303-5 +A1:2023-05 cl. 5.2 | PN-EN 303-5 +A1:2023-05 cl. 5.7 | PN-EN 303-5 +A1:2023-05 cl. 5.8 | EN 303-5:2021+A1:2022 cl. 5.2 | EN 303-5:2021+A1:2022 cl. 5.7 | EN 303-5:2021+A1:2022 cl. 5.8 | |
| 210 | Heating boilers for solid fuels with manual and automatic fuel feeding | Concentration of oxygen, carbon dioxide, carbon monoxide, nitrogen oxides, sulphur dioxide, volatile organic compounds O2 (1 – 21) % CO2 (0,1 – 20) % CO (3 – 1400) mg/m3 SO2 (19 – 3000) mg/m3 NO (9,0 – 435) mg/m3 NOX (14,0 – 700) mg/m3 OGC (1,8 – 1000) mg/m3 Dust concentration in flue gases Range (1,0 – 100) mg/m3 |
Electrochemical method - O2 (3,0 – 21,0) %; Paramagnetic method; NDIR method; Chemiluminescence method; Continuous flame ionisation detection method (FID); Gravimetric method | PN-EN 303-5:2021-09 cl. 5.2 | PN-EN 303-5:2021-09 cl. 5.7 | PN-EN 303-5:2021-09 cl. 5.8 | PN-EN 303-5 +A1:2023-05 cl. 5.2 | PN-EN 303-5 +A1:2023-05 cl. 5.7 | PN-EN 303-5 +A1:2023-05 cl. 5.8 | EN 303-5:2021+A1:2022 cl. 5.2 | EN 303-5:2021+A1:2022 cl. 5.7 | EN 303-5:2021+A1:2022 cl. 5.8 | |
| 211 | Heating boilers for solid fuels with manual and automatic fuel feeding | Emission of oxygen, carbon dioxide, carbon monoxide, nitrogen oxides, sulphur dioxide, volatile organic compounds O2 (1– 21) % CO2 (0,1 – 20) % CO (3 – 1400) mg/m3 SO2 (19 – 3000) mg/m3 NO (9,0 – 435) mg/m3 NOX (14,0 – 700) mg/m3 OGC (1,8 – 1000) mg/m3 Dust concentration in flue gases Range (1,0 – 100) mg/m3 |
Electrochemical method - O2 (3,0 – 21,0) %; Paramagnetic method; NDIR method; Chemiluminescence method; Continuous flame ionisation detection method (FID); Gravimetric method | PN-EN 303-5:2021-09 cl. 5.2 | PN-EN 303-5:2021-09 cl. 5.8 | PN-EN 303-5:2021-09 cl. 5.9.4 | PN-EN 303-5 +A1:2023-05 cl. 5.2 | PN-EN 303-5 +A1:2023-05 cl. 5.8 | PN-EN 303-5 +A1:2023-05 cl. 5.9.4 | EN 303-5:2021+A1:2022 cl. 5.2 | EN 303-5:2021+A1:2022 cl. 5.8 | EN 303-5:2021+A1:2022 cl. 5.9.4 | |
| 212 | Heating boilers for solid fuels with manual and automatic fuel feeding | Nominal heat output Range (0 – 500) kW |
Direct method | PN-EN 303-5:2021-09 cl. 5.7.2 | PN-EN 303-5 +A1:2023-05 cl. 5.7.2 | EN 303-5:2021+A1:2022 cl. 5.7.2 | |
| 213 | Heating boilers for solid fuels with manual and automatic fuel feeding | Minimum heat output Range (0 – 500) kW |
Direct method | PN-EN 303-5:2021-09 cl. 5.7.3 | PN-EN 303-5 +A1:2023-05 cl. 5.7.3 | EN 303-5:2021+A1:2022 cl. 5.7.3 | |
| 214 | Heating boilers for solid fuels with manual and automatic fuel feeding | Thermal efficiency | Direct method (calculated) | PN-EN 303-5:2021-09 cl. 5.7.6 | PN-EN 303-5:2021-09 cl. 5.9.3.2 | PN-EN 303-5 +A1:2023-05 cl. 5.7.6 | PN-EN 303-5 +A1:2023-05 cl. 5.9.3.2 | EN 303-5:2021+A1:2022 cl. 5.7.6 | EN 303-5:2021+A1:2022 cl. 5.9.3.2 | |
| 215 | Heating boilers for solid fuels with manual and automatic fuel feeding | Thermal efficiency | Indirect method (calculated) | PN-EN 303-5:2021-09 cl. 5.9.3.3 | PN-EN 303-5 +A1:2023-05 cl. 5.9.3.3 | EN 303-5:2021+A1:2022 cl. 5.9.3.3 | |
| 216 | Heating boilers for solid fuels with manual and automatic fuel feeding | Auxiliary electrical energy consumption Range (1 – 4000) W |
Method: power transducer | PN-EN 303-5:2021-09 cl. 5.7.7 | PN-EN 303-5 +A1:2023-05 cl. 5.7.7 | EN 303-5:2021+A1:2022 cl. 5.7.7 | |
| 217 | Heating boilers for solid fuels with manual and automatic fuel feeding | Useful efficiency nGCV (calculated) | PN-EN 303-5:2021-09 cl. 5.9.3.4 | PN-EN 303-5 +A1:2023-05 cl. 5.9.3.4 | EN 303-5:2021+A1:2022 cl. 5.9.3.4 | ||
| 218 | Heating boilers for solid fuels with manual and automatic fuel feeding | Seasonal space heating energy efficiency ns (calculated) | PN-EN 303-5:2021-09 cl. 5.9.3.5 | PN-EN 303-5 +A1:2023-05 cl. 5.9.3.5 | EN 303-5:2021+A1:2022 cl. 5.9.3.5 | ||
| 219 | Heating boilers for solid fuels with manual and automatic fuel feeding | Energy efficiency index EEI (calculated) | PN-EN 303-5:2021-09 cl. 5.9.3.6 | PN-EN 303-5 +A1:2023-05 cl. 5.9.3.6 | EN 303-5:2021+A1:2022 cl. 5.9.3.6 | ||
| 220 | Heating boilers for solid fuels with manual and automatic fuel feeding | Seasonal space heating emissions Es (calculated) | PN-EN 303-5:2021-09 cl. 5.9.4.4 | PN-EN 303-5 +A1:2023-05 cl. 5.9.4.4 | EN 303-5:2021+A1:2022 cl. 5.9.4.4 | ||
| 221 | Heating boilers for solid fuels with manual and automatic fuel feeding | Surface temperature Range (15 – 150) °C |
Resistance method | PN-EN 303-5:2021-09 cl. 5.11 | PN-EN 303-5 +A1:2023-05 cl. 5.11 | EN 303-5:2021+A1:2022 cl. 5.11 | |
| 222 | Heating boilers for solid fuels with manual and automatic fuel feeding | Handle temperature Range (0 – 150) °C |
Resistance method | PN-EN 303-5:2021-09 cl. 5.11 | PN-EN 303-5 +A1:2023-05 cl. 5.11 | EN 303-5:2021+A1:2022 cl. 5.11 | |
| 223 | Heating boilers for solid fuels with manual and automatic fuel feeding | Operation of the temperature controller outlet water temperature Range (60 – 110) °C |
Resistance method | PN-EN 303-5:2021-09 cl. 5.13 | PN-EN 303-5 +A1:2023-05 cl. 5.13 | EN 303-5:2021+A1:2022 cl. 5.13 | |
| 224 | Heating boilers for solid fuels with manual and automatic fuel feeding | Operation of the safety temperature limiter outlet water temperature Range (60 – 110) °C Carbon monoxide content CO (0,4 – 5,0) % |
Resistance method; NDIR method | PN-EN 303-5:2021-09 cl. 5.13 | PN-EN 303-5 +A1:2023-05 cl. 5.13 | EN 303-5:2021+A1:2022 cl. 5.13 | |
| 225 | Heating boilers for solid fuels with manual and automatic fuel feeding | Operation of quick-release systems: power failure heat dissipation failure outlet water temperature Range (60 – 110) °C Carbon monoxide content CO (0,4 – 5,0) % |
Resistance method; NDIR method | PN-EN 303-5:2021-09 cl. 5.14 | PN-EN 303-5 +A1:2023-05 cl. 5.14 | EN 303-5:2021+A1:2022 cl. 5.14 | |
| 226 | Heating boilers for solid fuels with manual and automatic fuel feeding | Test under conditions of blocked fuel supply outlet water temperature Range (60 – 110) °C Carbon monoxide content CO (0,4 – 5,0) % |
Resistance method; NDIR method | PN-EN 303-5:2021-09 cl. 5.16.2 | PN-EN 303-5 +A1:2023-05 cl. 5.16.2 | EN 303-5:2021+A1:2022 cl. 5.16.2 | |
| 227 | Heating boilers for solid fuels with manual and automatic fuel feeding | Safety test in the event of air supply failure. Combustion air fan failure, air supply system failure Carbon monoxide content CO (0,4 – 5,0) % |
NDIR method | PN-EN 303-5:2021-09 cl. 5.16.3 | PN-EN 303-5 +A1:2023-05 cl. 5.16.3 | EN 303-5:2021+A1:2022 cl. 5.16.3 | |
| 228 | Heating boilers for solid fuels with manual and automatic fuel feeding | Safety test with regard to heat conduction temperature Range (15 – 150) °C |
Resistance method | PN-EN 303-5:2021-09 cl. 5.16.4 | PN-EN 303-5 +A1:2023-05 cl. 5.16.4 | EN 303-5:2021+A1:2022 cl. 5.16.4 | |
Reference standards (179)
EN 303-5:2021+A1:2022 cl. 5.11
EN 303-5:2021+A1:2022 cl. 5.13
EN 303-5:2021+A1:2022 cl. 5.14
EN 303-5:2021+A1:2022 cl. 5.16.2
EN 303-5:2021+A1:2022 cl. 5.16.3
EN 303-5:2021+A1:2022 cl. 5.16.4
EN 303-5:2021+A1:2022 cl. 5.2
EN 303-5:2021+A1:2022 cl. 5.7
EN 303-5:2021+A1:2022 cl. 5.7.2
EN 303-5:2021+A1:2022 cl. 5.7.3
EN 303-5:2021+A1:2022 cl. 5.7.6
EN 303-5:2021+A1:2022 cl. 5.7.7
EN 303-5:2021+A1:2022 cl. 5.8
EN 303-5:2021+A1:2022 cl. 5.9.3.2
EN 303-5:2021+A1:2022 cl. 5.9.3.3
EN 303-5:2021+A1:2022 cl. 5.9.3.4
EN 303-5:2021+A1:2022 cl. 5.9.3.5
EN 303-5:2021+A1:2022 cl. 5.9.3.6
EN 303-5:2021+A1:2022 cl. 5.9.4
EN 303-5:2021+A1:2022 cl. 5.9.4.4
ISO 13319-1:2021
ISO 15713:2006
NIOSH 7907 Method, Issue 1, 20 May 2014
OSHA Method 1008
OSHA Method 1011
OSHA Method 182
OSHA Method 190
PN-71/Z-04041
PN-79/Z-04081/01
PN-79/Z-04107/02
PN-81/Z 04134/02
PN-81/Z-04134/03
PN-82/C-04576/08
PN-83/E-04040.03
PN-83/Z-04118/02
PN-84/Z 04135/02
PN-84/Z 04138/02
PN-86/Z 04166/02
PN-86/Z-04152/02
PN-87/Z-04100.03
PN-89/Z-04023/02
PN-93/Z-04152/06
PN-93/Z-15008/02
PN-93/Z-15008/03
PN-EN 1233:2000 cl. 3
PN-EN 12619:2013-05
PN-EN 13211+AC:2006
PN-EN 13284-1:2018-02
PN-EN 13649:2005
PN-EN 14181:2015
PN-EN 14253+A1:2011
PN-EN 14385:2025-05
PN-EN 14789:2017-04
PN-EN 14790:2017-04
PN-EN 14791:2017-04
PN-EN 14792:2017-04
PN-EN 15058:2017-04
PN-EN 1838:2013-11 excluding cl. 4.2.3-4.2.5; 4.3.3-4.3.5; 4.3.9; 4.4.3-4.4.6; 4.5; 5.
PN-EN 1899-2:2002
PN-EN 1911:2011
PN-EN 25663:2001
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 303-5 +A1:2023-05 cl. 5.11
PN-EN 303-5 +A1:2023-05 cl. 5.13
PN-EN 303-5 +A1:2023-05 cl. 5.14
PN-EN 303-5 +A1:2023-05 cl. 5.16.2
PN-EN 303-5 +A1:2023-05 cl. 5.16.3
PN-EN 303-5 +A1:2023-05 cl. 5.16.4
PN-EN 303-5 +A1:2023-05 cl. 5.2
PN-EN 303-5 +A1:2023-05 cl. 5.7
PN-EN 303-5 +A1:2023-05 cl. 5.7.2
PN-EN 303-5 +A1:2023-05 cl. 5.7.3
PN-EN 303-5 +A1:2023-05 cl. 5.7.6
PN-EN 303-5 +A1:2023-05 cl. 5.7.7
PN-EN 303-5 +A1:2023-05 cl. 5.8
PN-EN 303-5 +A1:2023-05 cl. 5.9.3.2
PN-EN 303-5 +A1:2023-05 cl. 5.9.3.3
PN-EN 303-5 +A1:2023-05 cl. 5.9.3.4
PN-EN 303-5 +A1:2023-05 cl. 5.9.3.5
PN-EN 303-5 +A1:2023-05 cl. 5.9.3.6
PN-EN 303-5 +A1:2023-05 cl. 5.9.4
PN-EN 303-5 +A1:2023-05 cl. 5.9.4.4
PN-EN 303-5:2021-09 cl. 5.11
PN-EN 303-5:2021-09 cl. 5.13
PN-EN 303-5:2021-09 cl. 5.14
PN-EN 303-5:2021-09 cl. 5.16.2
PN-EN 303-5:2021-09 cl. 5.16.3
PN-EN 303-5:2021-09 cl. 5.16.4
PN-EN 303-5:2021-09 cl. 5.2
PN-EN 303-5:2021-09 cl. 5.7
PN-EN 303-5:2021-09 cl. 5.7.2
PN-EN 303-5:2021-09 cl. 5.7.3
PN-EN 303-5:2021-09 cl. 5.7.6
PN-EN 303-5:2021-09 cl. 5.7.7
PN-EN 303-5:2021-09 cl. 5.8
PN-EN 303-5:2021-09 cl. 5.9.3.2
PN-EN 303-5:2021-09 cl. 5.9.3.3
PN-EN 303-5:2021-09 cl. 5.9.3.4
PN-EN 303-5:2021-09 cl. 5.9.3.5
PN-EN 303-5:2021-09 cl. 5.9.3.6
PN-EN 303-5:2021-09 cl. 5.9.4
PN-EN 303-5:2021-09 cl. 5.9.4.4
PN-EN 872:2007 + Ap1:2007
PN-EN ISO 10390:2022-09
PN-EN ISO 10523:2012
PN-EN ISO 11079:2008
PN-EN ISO 11885:2009
PN-EN ISO 21877:2020-03
PN-EN ISO 22155:2016-07
PN-EN ISO 3746:2011 excluding cl. 8.4
PN-EN ISO 3746:2011/Ap1:2017-09
PN-EN ISO 5349-1:2004
PN-EN ISO 5349-2:2004+A1:2015-11
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6878:2006 cl. 4 +Ap1:2010 + Ap2:2010
PN-EN ISO 6878:2006 cl. 8 +Ap1:2010 + Ap2:2010
PN-EN ISO 7243:2018-01
PN-EN ISO 7730:2006
PN-EN ISO 7730:2006/Ap2:2016-04
PN-EN ISO 9377-2:2003
PN-ISO 10381-4:2007
PN-ISO 10381-5:2009
PN-ISO 10396:2001
PN-ISO 11465:2026-03
PN-ISO 11466:2002
PN-ISO 13877:2004
PN-ISO 15705:2005
PN-ISO 16772:2009
PN-ISO 5667-10:2021-11 test procedure PB-20 issue 8 of 01.03.2022
PN-ISO 7150-1:2002
PN-ISO 8288:2002 Method A IR-106 issue 1 of 05.11.2018 cl. 3.1.4
PN-ISO 9280:2002
PN-ISO 9297:1994
PN-ISO 9612:2011 excluding the method covering strategy 2 - cl. 10
PN-N-01307:1994
PN-Z-04008-7:2002+Az1:2004
PN-Z-04009-11:2008
PN-Z-04016-10:2005
PN-Z-04030-7:1994
PN-Z-04045-16:2010
PN-Z-04106-3:2002
PN-Z-04108-5:2006
PN-Z-04136-3:2003
PN-Z-04263-1:2012
PN-Z-04323:2004
PN-Z-04354:2005
PN-Z-04434:2011
PN-Z-04469:2015-10
PN-Z-04472:2015-10+Ap1:2015-12
PN-Z-04476:2016-10
PN-Z-04487:2017-10
PN-Z-04502:2019-10
PN-Z-04507:2022-05
PN-Z-04507:2022-05/Ap1:2022-08
PN-Z-04508:2022-05
PN-Z-04508:2022-05/Ap1:2022-08
Principles and Methods of Assessing the Working Environment 1999, No. 22, pp. 91-95
Principles and Methods of Assessing the Working Environment 1999, No. 22, pp. 96-100
Principles and Methods of Assessing the Working Environment 2012, No. 4 (74), pp. 117–130
Principles and Methods of Assessing the Working Environment 2017, No. 2 (92), pp. 5–19
Principles and Methods of Assessing the Working Environment 2020, No. 1 (103), pp. 157–170
Test procedure PB 52 issue 3 of 28.08.2019
Test procedure PB 54 issue 1 of 15.05.2020
Test procedure PB 58 issue 1 of 16.04.2021
Test procedure PB-01 issue 8 of 24.06.2019
Test procedure PB-13 issue 10 of 18.09.2019
Test procedure PB-14 issue 10 of 18.09.2019
Test procedure PB-23 issue 7 of 24.06.2019
Test procedure PB-37 issue 5 of 24.06.2019
Test procedure PB-51 issue 5 of 10.06.2025
Test procedure PB-55 issue 1 of 10.09.2020
Test procedure PB-57 issue 1 of 16.04.2021
Test procedure PB-59 issue 1 of 01.03.2022
Test procedure PB-60 issue 1 of 01.03.2022
Test procedure PB-61 issue 1 of 03.03.2025
Test procedure PB–22 issue 6 of 24.06.2019
Test procedure PB–53 issue 2 of 07.07.2020
Annex 7 to the Regulation of the Minister of Climate and Environment of 07.09.2021 (consolidated text Journal of Laws 2023, item 1706) excluding cl. F