🇵🇱 CENTRUM NAUKOWO-BADAWCZE PL
Materials & polymersConstructionPetrochemistry & fuelsEnvironment
CENTRUM NAUKOWO-BADAWCZE is a laboratory accredited by PCA under number AB 1280 (Józefów, Poland). Its accreditation scope covers 58 test methods in the following areas: Materials & polymers, Construction, Petrochemistry & fuels, Environment. Test objects include: Cables, electrical and fiber-optic cables E, Chemical substances and their mixtures which may pose a risk of exp…, Construction products E, Secondary cells and batteries containing alkaline or other non-acid…. Most frequently used techniques: Abel closed-cup method, Burning behaviour by the oxygen index method, Method S.
At a glance
- Accreditation number: PCA AB 1280
- Methods in scope: 58
- Types of test objects: 40
- Techniques used: 6
- City: Józefów, Poland
- Accreditation number
- AB 1280
- Accreditation body
- PCA
- Address
- OCHRONY PRZECIWPOŻAROWEJ im. Józefa Tuliszkowskiego, - PAŃSTWOWY INSTYTUT BADAWCZY, ZESPÓŁ LABORATORIÓW PROCESÓW SPALANIA I WYBUCHOWOŚCI BW, ul. Nadwiślańska 213
- City
- Józefów, Poland
What this laboratory tests (40)
- Cables, electrical and fiber-optic cables E — 7 methods
- Chemical substances and their mixtures which may pose a risk of explosion during operation or technical processes: - liquid chemical products - liquid petroleum products - solid materials in the form of dusts, powders, granules E — 3 methods
- Construction products E — 3 methods
- Secondary cells and batteries containing alkaline or other non-acid electrolytes E — 3 methods
- Cables and wires in protection circuits E — 2 methods
- Cables, electrical and fiber-optic cables — 2 methods
- Flat textilesE — 2 methods
- Insulating, structural, furnishing and decorative building materials and products — 2 methods
- Plastics and other non-metallic materials E — 2 methods
- Upholstery and filling used in upholstered seats, armchairs, seats E — 2 methods
- Aerosol products and foams E — 1 method
- Cables, electric wires and optical fibers E — 1 method
- Chemical substances and their mixtures which may pose a risk of explosion during operation or technical processes: - liquid chemical products - liquid petroleum products — 1 method
- Chemical substances and their mixtures which may pose a risk of explosion during operation or technical processes: - liquid chemical products - liquid petroleum products - solid materials in the form of dusts, powders, granules — 1 method
- Chemical substances and their mixtures which may pose a risk of fire during operation or technical processes: - liquid - gas - solid in the form of dusts, powders, granules — 1 method
- and 25 more
Analytical techniques used (6)
- Abel closed-cup method — 1 method
- Burning behaviour by the oxygen index method — 1 method
- Method S — 1 method
- Radiant panel method — 1 method
- Single flame method — 1 method
- Single-chamber test — 1 method
Laboratory locations
- CENTRUM NAUKOWO-BADAWCZE (main site) — ul. Nadwiślańska 213, Józefów
- COMBUSTION AND EXPLOSIVENESS PROCESSES LABORATORIES GROUP BW — ul. Nadwiślańska 213, 05-420 Józefów k/Otwocka
Certificate information
- Issue date
- 13.07.2026
- Issue no.
- 19
Accreditation scope — test methods (58)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Combustion Processes and Explosibility Laboratories Team BW | |||||
| 1 | Roofs made of combustible materials, skylights, roof-lights | External and internal fire spread in an upwards and a downwards direction; Maximum length of external and internal damage; falling, burning droplets and debris from the exposed side; flaming / incandescent particles penetrating the roof structure; Area of openings; Fire spread in the transverse direction; Internal smouldering / glowing | PN-ENV 1187:2004 + A1:2007; point 4, method 1 | ||
| 2 | Textiles, elastic materials | Time until ignition of the specimen; Time until burning of the specimen ceases; Destroyed area of the specimen | PB/BW/1, 1st edition dated 17.05.2011 | ||
| 3 | Cables, electrical and fiber-optic cables | Gas acidity formed during the combustion of materials of electric cables by measuring pH and conductivity | PN-EN 50267-2-2:2001 | PN-EN 50267-2-3:2001 | ||
| 4 | Cables, electrical and fiber-optic cables | Gas acidity formed during the combustion of materials of electric cables by measuring pH and conductivity | PN-EN 50267-2-1:2001 | PN-EN 50267-2-2:2001 | PN-EN 50267-2-3:2001 | ||
| 5 | Chemical substances and their mixtures which may pose a risk of explosion during operation or technical processes: - liquid chemical products - liquid petroleum products - solid materials in the form of dusts, powders, granules | Flash point; Minimum ignition energy | ASTM D93:2013 | PN-EN 50281-2-1:2002 | PN-EN 13821:2004 | ASTM E2019:2013 | ||
| 6 | Chemical substances and their mixtures which may pose a risk of fire during operation or technical processes: - liquid - gas - solid in the form of dusts, powders, granules | Maximum explosion pressure; Maximum rate of explosion pressure rise; Explosion limits | ASTM E1226:2012 | ||
| 7 | Chemical substances and their mixtures which may pose a risk of explosion during operation or technical processes: - liquid chemical products - liquid petroleum products | Auto-ignition temperature of vapours Range 80°C to 600°C from 80°C to 600°C / 80°C to 600°C |
Method S | PN-EN 14522:2006 (liquids) | Method S | |
| 8 | Secondary cells and batteries containing alkaline or other non-acid electrolytes | Impact test; Overcharge test; Forced discharge test; BMS test (overcharge control of voltage, overcharge control of current, overheating control) | PN-EN 62619:2023 point 7.2.2, point 7.2.5 / 7.2.4, point 7.2.6, point 8.2.2, point 8.2.3, point 8.2.4 | ||
| 9 | Mobile smoke extraction fans | Static pressure; Flow rate (efficiency) | ANSI/AMCA Standard 240-22 | ANSI/AMCA Standard 210-25 | ||
| 10 | Insulating, structural, furnishing and decorative building materials and products | Smoke production smoke generation |
Single-chamber test | EN ISO 5659-2:2026 | |
| 11 | Insulating, structural, furnishing and decorative building materials and products | Lateral spread of flame critical heat flux heat release rate |
Radiant panel method | ISO 5658-2:2006/AMD1:2011 | |
| 12 | Fire-resistant cabinets for the storage of lithium-ion batteries | Temperature increase outside the test sample; Propagation | VDMA 24994:2024-08 | ||
| 13 | Construction products E | Time of persistent flaming of specimens; Relative mass loss of specimens; Temperature rise: of the furnace, inside the specimen, on the specimen surface Regulated area: E – Flexible scope of accreditation. The flexibility of the scope includes the elements indicated in the DA-10 document for the scope of accreditation of testing laboratories. The list of activities carried out under the flexible scope of accreditation is made publicly available or upon request by the accredited entity. "N" – Test method used in activities relevant for notification according to Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011 |
PN-EN ISO 1182 „N” “N” | ||
| 14 | Construction products E | Occurrence of ignition; Spread of flames; Ignition of the filter paper Regulated area: E – Flexible scope of accreditation. The flexibility of the scope includes the elements indicated in the DA-10 document for the scope of accreditation of testing laboratories. The list of activities carried out under the flexible scope of accreditation is made publicly available or upon request by the accredited entity. "N" – Test method used in activities relevant for notification according to Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011 |
PN-EN ISO 11925-2 „N” “N” | ||
| 15 | Construction products E | Total combustion heat /net combustion heat Regulated area: E – Flexible scope of accreditation. The flexibility of the scope includes the elements indicated in the DA-10 document for the scope of accreditation of testing laboratories. The list of activities carried out under the flexible scope of accreditation is made publicly available or upon request by the accredited entity. "N" – Test method used in activities relevant for notification according to Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011 |
PN-EN ISO 1716 „N” “N” | ||
| 16 | Construction products excluding Floors E | Heat release; Smoke release; Lateral flame spread; Dripping and falling off under fire Regulated area: E – Flexible scope of accreditation. The flexibility of the scope includes the elements indicated in the DA-10 document for the scope of accreditation of testing laboratories. The list of activities carried out under the flexible scope of accreditation is made publicly available or upon request by the accredited entity. "N" – Test method used in activities relevant for notification according to Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011 |
PN-EN 13823 „N” “N” | ||
| 17 | Floors, floor coverings E | Critical heat flux / heat flux at 30 minutes; Smoke production Regulated area: E – Flexible scope of accreditation. The flexibility of the scope includes the elements indicated in the DA-10 document for the scope of accreditation of testing laboratories. The list of activities carried out under the flexible scope of accreditation is made publicly available or upon request by the accredited entity. "N" – Test method used in activities relevant for notification according to Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011 |
PN-EN ISO 9239-1 „N” “N” | ||
| 18 | Outer walls containing combustible materials, insulation E | Temperature value at the measuring points on lines L1 and L2; Burning or smouldering on lines L1 and L2; Occurrence of burning debris; Burning after the test time Regulated area: E – Flexible scope of accreditation. The flexibility of the scope includes the elements indicated in the DA-10 document for the scope of accreditation of testing laboratories. The list of activities carried out under the flexible scope of accreditation is made publicly available or upon request by the accredited entity. "N" – Test method used in activities relevant for notification according to Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011 |
PN-B-02867 | ||
| 19 | Roofs with combustible materials, skylights, rooflights E | External and internal fire spread in an upwards and a downwards direction; Maximum length of external and internal destruction; falling, burning droplets and debris from the exposed side; flaming / incandescent particles penetrating the roof structure; Area of openings; Fire spreading in the transverse direction; Internal smouldering / glowing Regulated area: E – Flexible scope of accreditation. The flexibility of the scope includes the elements indicated in the DA-10 document for the scope of accreditation of testing laboratories. The list of activities carried out under the flexible scope of accreditation is made publicly available or upon request by the accredited entity. "N" – Test method used in activities relevant for notification according to Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011 |
PKN-CEN/TS 1187 “N” | ||
| 20 | Flat textilesE | Inflammation time Regulated area: E – Flexible scope of accreditation. The flexibility of the scope includes the elements indicated in the DA-10 document for the scope of accreditation of testing laboratories. The list of activities carried out under the flexible scope of accreditation is made publicly available or upon request by the accredited entity. |
PN-EN ISO 6940 | ||
| 21 | Flat textilesE | The time from the moment of applying the ignition flame until the breaking of the bottom control thread; The time from the moment of applying the ignition flame until the breaking of the middle control thread; The time from the moment of applying the ignition flame until the breaking of the top control thread Regulated area: E – Flexible scope of accreditation. The flexibility of the scope includes the elements indicated in the DA-10 document for the scope of accreditation of testing laboratories. The list of activities carried out under the flexible scope of accreditation is made publicly available or upon request by the accredited entity. |
PN-EN ISO 6941 | ||
| 22 | Stadium and upholstered seats E | Occurrence of flaming combustion; Self-sustaining smouldering; Burning time Regulated area: E – Flexible scope of accreditation. The flexibility of the scope includes the elements indicated in the DA-10 document for the scope of accreditation of testing laboratories. The list of activities carried out under the flexible scope of accreditation is made publicly available or upon request by the accredited entity. |
BS 5852 | ||
| 23 | Upholstery and filling used in upholstered seats, armchairs, seats E | Spread of combustion; Destruction of the tested system; Smouldering to the sample edges; Smouldering over the entire thickness, - smouldering for more than 1 h; Presence of active smouldering in the final test; Occurrence of flames on the tested system Regulated area: E – Flexible scope of accreditation. The flexibility of the scope includes the elements indicated in the DA-10 document for the scope of accreditation of testing laboratories. The list of activities carried out under the flexible scope of accreditation is made publicly available or upon request by the accredited entity. |
PN-EN 1021-1 | ||
| 24 | Upholstery and filling used in upholstered seats, armchairs, seats E | Spread of combustion; Destruction of the tested system; Smouldering to the sample edges; Smouldering over the entire thickness; Smouldering for more than 1 h; Presence of active smouldering in the final test; Occurrence of flame burning to the sample edges; Burning throughout the thickness of the sample; Burning for more than 120 seconds once the burner tube is removed Regulated area: E – Flexible scope of accreditation. The flexibility of the scope includes the elements indicated in the DA-10 document for the scope of accreditation of testing laboratories. The list of activities carried out under the flexible scope of accreditation is made publicly available or upon request by the accredited entity. |
PN-EN 1021-2 | ||
| 25 | Noise abatement devices E | Size of damaged surface; Burning throughout; Discoloration; Duration of the flame; Destruction area; Reaction to fire Regulated area: E – Flexible scope of accreditation. The flexibility of the scope includes the elements indicated in the DA-10 document for the scope of accreditation of testing laboratories. The list of activities carried out under the flexible scope of accreditation is made publicly available or upon request by the accredited entity. |
PN-EN 1794-2 | PN-EN 1794-3 excluding cl. 5.2.3. / excluding cl. 5.2.3 | ||
| 26 | Plastics and other non-metallic materials E | Afterflame time; Afterglow time; Spread of flames and glowing; Ignition of cotton pad; Burn-through of the specimen; Damaged area Regulated area: E – Flexible scope of accreditation. The flexibility of the scope includes the elements indicated in the DA-10 document for the scope of accreditation of testing laboratories. The list of activities carried out under the flexible scope of accreditation is made publicly available or upon request by the accredited entity. |
PN-EN 60695-11-5 | PN-EN 60695-11-10 | PN-EN 60695-11-20 | ||
| 27 | Plastics and other non-metallic materials E | Flammability Regulated area: E – Flexible scope of accreditation. The flexibility of the scope includes the elements indicated in the DA-10 document for the scope of accreditation of testing laboratories. The list of activities carried out under the flexible scope of accreditation is made publicly available or upon request by the accredited entity. |
Burning behaviour by the oxygen index method | PN-EN ISO 4589-2 | |
| 28 | Insulation, construction, outfitting and decoration materials and construction products E | Rate of heat and smoke release release of heat release of smoke mass combustion rate Regulated area: E – Flexible scope of accreditation. The flexibility of the scope includes the elements indicated in the DA-10 document for the scope of accreditation of testing laboratories. The list of activities carried out under the flexible scope of accreditation is made publicly available or upon request by the accredited entity. |
ISO 5660-1 | ||
| 29 | Cables, electrical and fiber-optic cables E | Release of heat; Release of smoke; Spread of flames; Occurrence of falling burning fragments Regulated area: E – Flexible scope of accreditation. The flexibility of the scope includes the elements indicated in the DA-10 document for the scope of accreditation of testing laboratories. The list of activities carried out under the flexible scope of accreditation is made publicly available or upon request by the accredited entity. |
PN-EN 50399 | ||
| 30 | Cables, electrical and fiber-optic cables E | Vertical spread of flames along a single insulated wire or cable extent and type of damage spread of flame burning droplets Regulated area: E – Flexible scope of accreditation. The flexibility of the scope includes the elements indicated in the DA-10 document for the scope of accreditation of testing laboratories. The list of activities carried out under the flexible scope of accreditation is made publicly available or upon request by the accredited entity. |
PN-EN 60332-1-2 | PN-EN 60332-2-2 | PN-EN 60332-1-3 | ||
| 31 | Cables, electrical and fiber-optic cables E | Gas acidity formed during the combustion of materials of electric cables by measuring pH and conductivity Regulated area: E – Flexible scope of accreditation. The flexibility of the scope includes the elements indicated in the DA-10 document for the scope of accreditation of testing laboratories. The list of activities carried out under the flexible scope of accreditation is made publicly available or upon request by the accredited entity. |
PN-EN 60754-2 | ||
| 32 | Cables, electrical and fiber-optic cables E | Density of smoke emitted by burning wires or cables release of smoke Regulated area: E – Flexible scope of accreditation. The flexibility of the scope includes the elements indicated in the DA-10 document for the scope of accreditation of testing laboratories. The list of activities carried out under the flexible scope of accreditation is made publicly available or upon request by the accredited entity. |
PN-EN 61034-1 | PN-EN 61034-2 | ||
| 33 | Cables, electrical and fiber-optic cables E | Spread of flame Regulated area: E – Flexible scope of accreditation. The flexibility of the scope includes the elements indicated in the DA-10 document for the scope of accreditation of testing laboratories. The list of activities carried out under the flexible scope of accreditation is made publicly available or upon request by the accredited entity. |
PN-EN 60332-3-21 | PN-EN 60332-3-22 | PN-EN 60332-3-23 | PN-EN 60332-3-24 | PN-EN 60332-3-25 | PN-EN 50305 cl. 9.1 | ||
| 34 | Cables, electrical and fiber-optic cables E | Content of acidic halogen gas formed during combustion of materials of electric cables Regulated area: E – Flexible scope of accreditation. The flexibility of the scope includes the elements indicated in the DA-10 document for the scope of accreditation of testing laboratories. The list of activities carried out under the flexible scope of accreditation is made publicly available or upon request by the accredited entity. |
PN-EN 60754-1 | ||
| 35 | Cables, electrical and fiber-optic cables E | Measurement of low level of halogen content formed during combustion of materials of electric cables Regulated area: E – Flexible scope of accreditation. The flexibility of the scope includes the elements indicated in the DA-10 document for the scope of accreditation of testing laboratories. The list of activities carried out under the flexible scope of accreditation is made publicly available or upon request by the accredited entity. |
PN-EN 60754-3 excluding cl. 7.6 | ||
| 36 | Cables and wires in protection circuits E | Flammability, continuity of energy supply Regulated area: E – Flexible scope of accreditation. The flexibility of the scope includes the elements indicated in the DA-10 document for the scope of accreditation of testing laboratories. The list of activities carried out under the flexible scope of accreditation is made publicly available or upon request by the accredited entity. |
PN-EN 50200 | PN-EN 50362 | PN-EN IEC 60331-1 | BS 8434-2 | ||
| 37 | Cables and wires in protection circuits E | Flammability, continuity of energy supply Regulated area: E – Flexible scope of accreditation. The flexibility of the scope includes the elements indicated in the DA-10 document for the scope of accreditation of testing laboratories. The list of activities carried out under the flexible scope of accreditation is made publicly available or upon request by the accredited entity. |
PN-IEC 60331-21 | PN-IEC 60331-23 | ||
| 38 | Solid electro-insulating products E | Resistance to incandescent wire occurrence of ignition or glowing Regulated area: E – Flexible scope of accreditation. The flexibility of the scope includes the elements indicated in the DA-10 document for the scope of accreditation of testing laboratories. The list of activities carried out under the flexible scope of accreditation is made publicly available or upon request by the accredited entity. |
PN-EN 60695-2-10 | PN-EN 60695-2-11 | PN-EN 60695-2-12 | PN-EN 60695-2-13 | ||
| 39 | Chemical substances and their mixtures which may pose a risk of explosion during operation or technical processes: - liquid chemical products - liquid petroleum products - solid materials in the form of dusts, powders, granules E | Flash point Regulated area: E – Flexible scope of accreditation. The flexibility of the scope includes the elements indicated in the DA-10 document for the scope of accreditation of testing laboratories. The list of activities carried out under the flexible scope of accreditation is made publicly available or upon request by the accredited entity. |
PN-EN ISO 2719 | ||
| 40 | Chemical substances and their mixtures which may pose a risk of explosion during operation or technical processes: - liquid chemical products - liquid petroleum products - solid materials in the form of dusts, powders, granules E | Flash point Range -8,5°C to 75,0°C -8,5°C to 75,0°C Regulated area: E – Flexible scope of accreditation. The flexibility of the scope includes the elements indicated in the DA-10 document for the scope of accreditation of testing laboratories. The list of activities carried out under the flexible scope of accreditation is made publicly available or upon request by the accredited entity. |
Abel closed-cup method | PN-EN ISO 13736 | |
| 41 | Chemical substances and their mixtures which may pose a risk of explosion during operation or technical processes: - liquid chemical products - liquid petroleum products - solid materials in the form of dusts, powders, granules E | Maximum explosion pressure; Maximum rate of explosion pressure rise; Explosion limits Regulated area: E – Flexible scope of accreditation. The flexibility of the scope includes the elements indicated in the DA-10 document for the scope of accreditation of testing laboratories. The list of activities carried out under the flexible scope of accreditation is made publicly available or upon request by the accredited entity. |
PN-EN 14034-1 | PN-EN 14034-2 | PN-EN 14034-3 | PN-EN 1839 excluding cl. 4.4. / excluding cl. 4.4 | PN-EN 15967 | ||
| 42 | Materials used in the construction of the interior of motor vehicles E | Combustibility; Fusibility; Resistance to absorption of fuels and lubricants burning time flame spread burning rate flame spread flammability occurrence of flaming droplets and particles Regulated area: E – Flexible scope of accreditation. The flexibility of the scope includes the elements indicated in the DA-10 document for the scope of accreditation of testing laboratories. The list of activities carried out under the flexible scope of accreditation is made publicly available or upon request by the accredited entity. |
Single flame method | PN-ISO 3795 | UN/ECE Regulation No. 118, Annex 6 | UN/ECE Regulation No. 118, Annex 7 | UN/ECE Regulation No. 118, Annex 8 | UN/ECE Regulation No. 118, Annex 9 | UN/ECE Regulation No. 118, Annex 10 | |
| 43 | Double acting hydraulic rescue tools E | Marking, weight, geometry (dimensions), arrangement of handles, stability, correct operation of the actuator for manual control, cycle time (openings and closings); Parameters and functional features, including: minimum operating force, tool integrity, tightness and checking of quick couplings, overload capability, grip of the spreader tips, examination of the gripping surface of the cylinder foot, cutting ability minimum potency Range (compression 20 - 290 kN, tension 20 - 180 kN) Regulated area: E – Flexible scope of accreditation. The flexibility of the scope includes the elements indicated in the DA-10 document for the scope of accreditation of testing laboratories. The list of activities carried out under the flexible scope of accreditation is made publicly available or upon request by the accredited entity. |
PN-EN 13204 | ||
| 44 | Cables, electric wires and optical fibers E | Attenuation and attenuation changes for wavelengths: 850 nm and 1300 nm (multimode fibres) 1310 nm and 1550 nm (single-mode fibres) Regulated area: E – Flexible scope of accreditation. The flexibility of the scope includes the elements indicated in the DA-10 document for the scope of accreditation of testing laboratories. The list of activities carried out under the flexible scope of accreditation is made publicly available or upon request by the accredited entity. |
PB/BW/3 (based on PN-EN 50582) | ||
| 45 | Aerosol products and foams E | Ignition distance, aerosol internal pressure, product mass, time equivalent tcq, deflagration density Regulated area: E – Flexible scope of accreditation. The flexibility of the scope includes the elements indicated in the DA-10 document for the scope of accreditation of testing laboratories. The list of activities carried out under the flexible scope of accreditation is made publicly available or upon request by the accredited entity. |
Regulation of the Minister of Economy of 5 November 2009 on detailed requirements for aerosols, Appendix No. 3 | ||
| 46 | Fire extinguishing systems used in vehicles E | The time for extinguishing test fires and the time for refraining from re-ignition Regulated area: E – Flexible scope of accreditation. The flexibility of the scope includes the elements indicated in the DA-10 document for the scope of accreditation of testing laboratories. The list of activities carried out under the flexible scope of accreditation is made publicly available or upon request by the accredited entity. |
UN/ECE Regulation 107, Annex 13 | ||
| 47 | Rachargeable Energy Storage System (REESS) used in road vehicles E | Thermal shock and cycling test; Resistance of the REESS to exposure to fire from outside; External short circuit protection; Over-temperature protection Regulated area: E – Flexible scope of accreditation. The flexibility of the scope includes the elements indicated in the DA-10 document for the scope of accreditation of testing laboratories. The list of activities carried out under the flexible scope of accreditation is made publicly available or upon request by the accredited entity. |
UN Regulation No. 100, Annex 9B, Annex 9E, Annex 9F, Annex 9I point 4 | ||
| 48 | Secondary cells and batteries containing alkaline or other non-acid electrolytes E | External short circuit protection; Drop test; Thermal abuse test; Propagation test Regulated area: E – Flexible scope of accreditation. The flexibility of the scope includes the elements indicated in the DA-10 document for the scope of accreditation of testing laboratories. The list of activities carried out under the flexible scope of accreditation is made publicly available or upon request by the accredited entity. |
PN-EN IEC 62619 point 7.2.1, point 7.2.3, point 7.2.4, point 7.3.3 | ||
| 49 | Secondary cells and batteries containing alkaline or other non-acid electrolytes E | External short circuit protection; Drop test; Thermal abuse test Regulated area: E – Flexible scope of accreditation. The flexibility of the scope includes the elements indicated in the DA-10 document for the scope of accreditation of testing laboratories. The list of activities carried out under the flexible scope of accreditation is made publicly available or upon request by the accredited entity. |
PN-EN IEC 62133-2 point 7.3.2, point 7.3.3, point 7.3.4 | ||
| 50 | Secondary cells and batteries containing alkaline or other non-acid electrolytes E | External short circuit protection; Drop test Regulated area: E – Flexible scope of accreditation. The flexibility of the scope includes the elements indicated in the DA-10 document for the scope of accreditation of testing laboratories. The list of activities carried out under the flexible scope of accreditation is made publicly available or upon request by the accredited entity. |
PN-EN IEC 63056 point 7.6, point 7.9 | ||
| 51 | Conduit systems for cable management E | Fire spreading Regulated area: E – Flexible scope of accreditation. The flexibility of the scope includes the elements indicated in the DA-10 document for the scope of accreditation of testing laboratories. The list of activities carried out under the flexible scope of accreditation is made publicly available or upon request by the accredited entity. |
PN-EN 61386-1 point 13.1.3.1 | ||
| 52 | Photovoltaic (PV) module E | Ignitability; Fire spread Regulated area: E – Flexible scope of accreditation. The flexibility of the scope includes the elements indicated in the DA-10 document for the scope of accreditation of testing laboratories. The list of activities carried out under the flexible scope of accreditation is made publicly available or upon request by the accredited entity. |
PN-EN IEC 61730-2 point 10.18, point 10.17, Annex B point B2 | ||
| 53 | Products, materials, construction works, Electrical products and equipment, Machines and devices, Plastic and rubber products, Telecommunication products and equipment, Electronic products and equipment E | Test A – cold - operational; Test B – dry heat - operational Regulated area: E – Flexible scope of accreditation. The flexibility of the scope includes the elements indicated in the DA-10 document for the scope of accreditation of testing laboratories. The list of activities carried out under the flexible scope of accreditation is made publicly available or upon request by the accredited entity. |
PN-EN 60068-2-1 | PN-EN 60068-2-2 | ||
| Test methods | |||||
| 54 | Finishing of interior, exterior walls and ceilings | ASSESSMENT OF PERFORMANCE BASED ON TESTS (System 3) Regulated area: Type of activity: ASSESSMENT OF PERFORMANCE BASED ON TESTS (System 3). Reference document: Regulation of the European Parliament and of the Council (EU) No. 305/2011 of 9 March 2011 with subsequent amendments laying down harmonised conditions for the marketing of construction products and repealing Council Directive 89/106/EEC. Number of the decision of the Commission: 98/437/EC. Product(s) tested. Harmonised technical specifications. The laboratory meets the requirements of Regulation No. 305/2011 of 9 March 2011 with subsequent amendments in the scope of activities provided for a testing laboratory (Annex V, Section 2, point 3 of the Regulation No. 305/2011) in this respect. |
EN 13245-2:2008 | EN 13245-2:2008/AC:2009 | EN 14716:2004 | ||
| 55 | Roofing, skylights, roof windows | ASSESSMENT OF PERFORMANCE BASED ON TESTS (System 3) Regulated area: Type of activity: ASSESSMENT OF PERFORMANCE BASED ON TESTS (System 3). Reference document: Regulation of the European Parliament and of the Council (EU) No. 305/2011 of 9 March 2011 with subsequent amendments laying down harmonised conditions for the marketing of construction products and repealing Council Directive 89/106/EEC. Number of the decision of the Commission: 98/436/EC. Product(s) tested. Harmonised technical specifications. The laboratory meets the requirements of Regulation No. 305/2011 of 9 March 2011 with subsequent amendments in the scope of activities provided for a testing laboratory (Annex V, Section 2, point 3 of the Regulation No. 305/2011) in this respect. |
EN 16153:2013 | EN 16153:2013+A1:2015 | ||
| 56 | Power cables, control cables and telecommunication cables | ASSESSMENT OF PERFORMANCE BASED ON TESTS (System 3) Regulated area: Type of activity: ASSESSMENT OF PERFORMANCE BASED ON TESTS (System 3). Reference document: Regulation of the European Parliament and of the Council (EU) No. 305/2011 of 9 March 2011 with subsequent amendments laying down harmonised conditions for the marketing of construction products and repealing Council Directive 89/106/EEC. Number of the decision of the Commission: 2011/284/EU. Product(s) tested. Harmonised technical specifications. The laboratory meets the requirements of Regulation No. 305/2011 of 9 March 2011 with subsequent amendments in the scope of activities provided for a testing laboratory (Annex V, Section 2, point 3 of the Regulation No. 305/2011) in this respect. |
EN 50575:2014+A1:2016 | ||
| 57 | Resistance to external fire | Essential characteristic; Technical specification Regulated area: Type of activity: ASSESSMENT OF PERFORMANCE. Reference document: Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011, as amended, laying down harmonised conditions for the marketing of construction products and repealing Council Directive 89/106/EEC. The laboratory meets the requirements of Regulation No 305/2011 of 9 March 2011, as amended, for the activities provided for a testing laboratory (Annex V, Section 2, point 3 of Regulation No 305/2011) in the above scope. |
TS 1187 | ||
| 58 | Reaction to fire | Essential characteristic; Technical specification Regulated area: Type of activity: ASSESSMENT OF PERFORMANCE. Reference document: Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011, as amended, laying down harmonised conditions for the marketing of construction products and repealing Council Directive 89/106/EEC. The laboratory meets the requirements of Regulation No 305/2011 of 9 March 2011, as amended, for the activities provided for a testing laboratory (Annex V, Section 2, point 3 of Regulation No 305/2011) in the above scope. |
EN ISO 1182 | EN ISO 1716 | EN ISO 9239-1 | EN ISO 11925-2 | EN 13823 | ||
Reference standards (99)
ANSI/AMCA Standard 210-25
ANSI/AMCA Standard 240-22
ASTM D93:2013
ASTM E1226:2012
ASTM E2019:2013
BS 5852
BS 8434-2
EN 13245-2:2008
EN 13245-2:2008/AC:2009
EN 13823
EN 14716:2004
EN 16153:2013
EN 16153:2013+A1:2015
EN 50575:2014+A1:2016
EN ISO 1182
EN ISO 11925-2
EN ISO 1716
EN ISO 5659-2:2026
EN ISO 9239-1
ISO 5658-2:2006/AMD1:2011
ISO 5660-1
Method S
PB/BW/1, 1st edition dated 17.05.2011
PB/BW/3 (based on PN-EN 50582)
PKN-CEN/TS 1187 “N”
PN-B-02867
PN-EN 1021-1
PN-EN 1021-2
PN-EN 13204
PN-EN 13821:2004
PN-EN 13823 „N” “N”
PN-EN 14034-1
PN-EN 14034-2
PN-EN 14034-3
PN-EN 14522:2006 (liquids)
PN-EN 15967
PN-EN 1794-2
PN-EN 1794-3 excluding cl. 5.2.3. / excluding cl. 5.2.3
PN-EN 1839 excluding cl. 4.4. / excluding cl. 4.4
PN-EN 50200
PN-EN 50267-2-1:2001
PN-EN 50267-2-2:2001
PN-EN 50267-2-3:2001
PN-EN 50281-2-1:2002
PN-EN 50305 cl. 9.1
PN-EN 50362
PN-EN 50399
PN-EN 60068-2-1
PN-EN 60068-2-2
PN-EN 60332-1-2
PN-EN 60332-1-3
PN-EN 60332-2-2
PN-EN 60332-3-21
PN-EN 60332-3-22
PN-EN 60332-3-23
PN-EN 60332-3-24
PN-EN 60332-3-25
PN-EN 60695-11-10
PN-EN 60695-11-20
PN-EN 60695-11-5
PN-EN 60695-2-10
PN-EN 60695-2-11
PN-EN 60695-2-12
PN-EN 60695-2-13
PN-EN 60754-1
PN-EN 60754-2
PN-EN 60754-3 excluding cl. 7.6
PN-EN 61034-1
PN-EN 61034-2
PN-EN 61386-1 point 13.1.3.1
PN-EN 62619:2023 point 7.2.2, point 7.2.5 / 7.2.4, point 7.2.6, point 8.2.2, point 8.2.3, point 8.2.4
PN-EN IEC 60331-1
PN-EN IEC 61730-2 point 10.18, point 10.17, Annex B point B2
PN-EN IEC 62133-2 point 7.3.2, point 7.3.3, point 7.3.4
PN-EN IEC 62619 point 7.2.1, point 7.2.3, point 7.2.4, point 7.3.3
PN-EN IEC 63056 point 7.6, point 7.9
PN-EN ISO 1182 „N” “N”
PN-EN ISO 11925-2 „N” “N”
PN-EN ISO 13736
PN-EN ISO 1716 „N” “N”
PN-EN ISO 2719
PN-EN ISO 4589-2
PN-EN ISO 6940
PN-EN ISO 6941
PN-EN ISO 9239-1 „N” “N”
PN-ENV 1187:2004 + A1:2007; point 4, method 1
PN-IEC 60331-21
PN-IEC 60331-23
PN-ISO 3795
Regulation of the Minister of Economy of 5 November 2009 on detailed requirements for aerosols, Appendix No. 3
UN/ECE Regulation 107, Annex 13
UN/ECE Regulation No. 118, Annex 10
UN/ECE Regulation No. 118, Annex 6
UN/ECE Regulation No. 118, Annex 7
UN/ECE Regulation No. 118, Annex 8
UN/ECE Regulation No. 118, Annex 9
UN Regulation No. 100, Annex 9B, Annex 9E, Annex 9F, Annex 9I point 4
TS 1187
VDMA 24994:2024-08