🇵🇱 KATARZYNA ROKOSSOWSKA PL
EnvironmentAutomotive
KATARZYNA ROKOSSOWSKA is a laboratory accredited by PCA under number AB 1263 (Poznań, Poland). Its accreditation scope covers 23 test methods in the following areas: Environment, Automotive. Test objects include: Workplace environment − electromagnetic field from equipment used i…, Workplace environment − electromagnetic field from industrial insta…, Workplace environment − electromagnetic field originating from radi…, Environment – electromagnetic field in the vicinity of electric pow…. Most frequently used techniques: Direct measurement method, Calculation method.
At a glance
- Accreditation number: PCA AB 1263
- Methods in scope: 23
- Types of test objects: 7
- Techniques used: 2
- City: Poznań, Poland
- Accreditation number
- AB 1263
- Accreditation body
- PCA
- Address
- PRZEDSIĘBIORSTWO USŁUGOWE „LAB-TOP”, Daszewice, ul. Pogodna 7/3, 61-160 Poznań
- City
- Poznań, Poland
What this laboratory tests (7)
- Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy units - physiotherapy diathermy units - magnetic resonance scanners — 4 methods
- Workplace environment − electromagnetic field from industrial installations and equipment: - arc welding equipment - resistance welding machines - industrial magnetisers and demagnetisers - electrolytic installations - NMR spectrometers - dielectric heating equipment - induction heating equipment - industrial microwave furnaces, heaters and dryers, - equipment for the production and processing of plastics - electric vehicles - soldering equipment - electrical discharge machines - resistance and arc furnaces - electric generators and motors - inverters - industrial static field sources — 4 methods
- Workplace environment − electromagnetic field originating from radiocommunication and anti-theft systems: - handheld radiotelephones, short range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) — 4 methods
- Environment – electromagnetic field in the vicinity of electric power substations and power lines — 3 methods
- Workplace environment – electromagnetic field in the workspace during the use of magnetotherapy or magnetostimulation devices — 3 methods
- Workplace environment – electromagnetic field in the workspace during the use of power systems and alternating current electrical supply installations in the power industry — 3 methods
- Environment – electromagnetic field (electromagnetic overhead lines without voltage limitation) — 2 methods
Analytical techniques used (2)
- Direct measurement method — 15 methods
- Calculation method — 2 methods
Laboratory locations
- KATARZYNA ROKOSSOWSKA (main site) — ul. Pogodna 7/3, 61-160 Poznań
- LAB-TOP Physical Agents Testing Laboratory — ul. Forteczna 17, 61-362 Poznań
Certificate information
- Issue date
- 07.08.2026
- Issue no.
- 20
Accreditation scope — test methods (23)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| LAB-TOP Physical Agents Testing Laboratory | |||||
| 1 | Environment – electromagnetic field in the vicinity of electric power substations and power lines | Electric field strength: in the frequency range 50 Hz Range 0,1 kV/m – 50 kV/m Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the legally regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Direct measurement method | Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630) | |
| 2 | Environment – electromagnetic field in the vicinity of electric power substations and power lines | Magnetic flux density: in the frequency range 50 Hz Range 0,02 µT – 10 mT Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the legally regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Direct measurement method | Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630) | |
| 3 | Environment – electromagnetic field in the vicinity of electric power substations and power lines | Magnetic field strength: in the frequency range 50 Hz (calculated) Regulated area: Measurements of the electromagnetic field in the environment performed for the purposes of the legally regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 – Environmental Protection Law. |
Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630) | ||
| 4 | Workplace environment – electromagnetic field in the workspace during the use of power systems and alternating current electrical supply installations in the power industry | Electric field strength: in the frequency range from 5 Hz to 1000 Hz Range 1 V/m – 50 kV/m Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the legally regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (Journal of Laws of 2018, item 331). |
Direct measurement method | Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 91–150 | |
| 5 | Workplace environment – electromagnetic field in the workspace during the use of power systems and alternating current electrical supply installations in the power industry | Magnetic flux density: in the frequency range from 5 Hz to 1000 Hz Range 0,02 µT – 10 mT Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the legally regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (Journal of Laws of 2018, item 331). |
Direct measurement method | Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 91–150 | |
| 6 | Workplace environment – electromagnetic field in the workspace during the use of power systems and alternating current electrical supply installations in the power industry | Magnetic field strength: in the frequency range from 5 Hz to 1000 Hz (calculated) Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the legally regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (Journal of Laws of 2018, item 331). |
Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 91–150 | ||
| 7 | Workplace environment – electromagnetic field in the workspace during the use of magnetotherapy or magnetostimulation devices | Electric field strength: in the frequency range from 5 Hz to 400 kHz Range 1 V/m – 50 kV/m Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the legally regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (Journal of Laws of 2018, item 331). |
Direct measurement method | Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 151–180 | |
| 8 | Workplace environment – electromagnetic field in the workspace during the use of magnetotherapy or magnetostimulation devices | Magnetic flux density: in the frequency range from 5 Hz to 400 kHz Range 0,02 µT – 10 mT Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the legally regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (Journal of Laws of 2018, item 331). |
Direct measurement method | Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 151–180 | |
| 9 | Workplace environment – electromagnetic field in the workspace during the use of magnetotherapy or magnetostimulation devices | Magnetic field strength: in the frequency range from 5 Hz to 400 kHz (calculated) Regulated area: Measurements of the electromagnetic field in the working environment performed for the purposes of the legally regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the Regulation of the Minister of Family, Labour and Social Policy of 29.06.2016 (Journal of Laws of 2018, item 331). |
Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 151–180 | ||
| 10 | Workplace environment − electromagnetic field from industrial installations and equipment: - arc welding equipment - resistance welding machines - industrial magnetisers and demagnetisers - electrolytic installations - NMR spectrometers - dielectric heating equipment - induction heating equipment - industrial microwave furnaces, heaters and dryers, - equipment for the production and processing of plastics - electric vehicles - soldering equipment - electrical discharge machines - resistance and arc furnaces - electric generators and motors - inverters - industrial static field sources | Electric field strength: in the frequency range from 5 Hz to 400 kHz Range 1 V/m – 50 kV/m in the frequency range from 100 kHz to 18 GHz Range (0,5 – 900) V/m |
Direct measurement method | PN-T-06580-3:2002 Method adapted to the regulated area | Instruction IB-02_Z-01 issue 5 of 31.07.2026 | |
| 11 | Workplace environment − electromagnetic field from industrial installations and equipment: - arc welding equipment - resistance welding machines - industrial magnetisers and demagnetisers - electrolytic installations - NMR spectrometers - dielectric heating equipment - induction heating equipment - industrial microwave furnaces, heaters and dryers, - equipment for the production and processing of plastics - electric vehicles - soldering equipment - electrical discharge machines - resistance and arc furnaces - electric generators and motors - inverters - industrial static field sources | Magnetic flux density: in the frequency range 0 Hz Range 200 µT – 1200 mT in the frequency range from 5 Hz to 400 kHz Range 0,02 µT – 12 mT |
Direct measurement method | PN-T-06580-3:2002 Method adapted to the regulated area | Instruction IB-02_Z-01 issue 5 of 31.07.2026 | |
| 12 | Workplace environment − electromagnetic field from industrial installations and equipment: - arc welding equipment - resistance welding machines - industrial magnetisers and demagnetisers - electrolytic installations - NMR spectrometers - dielectric heating equipment - induction heating equipment - industrial microwave furnaces, heaters and dryers, - equipment for the production and processing of plastics - electric vehicles - soldering equipment - electrical discharge machines - resistance and arc furnaces - electric generators and motors - inverters - industrial static field sources | Magnetic field strength: in the frequency range from 20 Hz to 20 kHz Range 1,6 A/m – 7 kA/m in the frequency range from 0,3 MHz to 30 MHz Range (0,0105 – 16) A/m in the frequency range from 0,026 GHz to 1,0 GHz Range (0,013 – 4,2) A/m |
Direct measurement method | PN-T-06580-3:2002 Method adapted to the regulated area | Instruction IB-02_Z-01 issue 5 of 31.07.2026 | |
| 13 | Workplace environment − electromagnetic field from industrial installations and equipment: - arc welding equipment - resistance welding machines - industrial magnetisers and demagnetisers - electrolytic installations - NMR spectrometers - dielectric heating equipment - induction heating equipment - industrial microwave furnaces, heaters and dryers, - equipment for the production and processing of plastics - electric vehicles - soldering equipment - electrical discharge machines - resistance and arc furnaces - electric generators and motors - inverters - industrial static field sources | Magnetic field strength: in the frequency range 0 Hz in the frequency range from 5 Hz to 400 kHz in the frequency range from 1 GHz to 18 GHz (calculated) |
PN-T-06580-3:2002 Method adapted to the regulated area | Instruction IB-02_Z-01 issue 5 of 31.07.2026 | ||
| 14 | Workplace environment − electromagnetic field originating from radiocommunication and anti-theft systems: - handheld radiotelephones, short range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) | Electric field strength: in the frequency range from 5 Hz to 400 kHz Range 1 V/m – 50 kV/m in the frequency range from 100 kHz to 18 GHz Range (0,5 – 900) V/m |
Direct measurement method | PN-T-06580-3:2002 Method adapted to the regulated area | Instruction IB-02_Z-04 issue 2 of 31.07.2026 | |
| 15 | Workplace environment − electromagnetic field originating from radiocommunication and anti-theft systems: - handheld radiotelephones, short range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) | Magnetic flux density: in the frequency range 0 Hz Range 200 µT – 1200 mT in the frequency range from 5 Hz to 400 kHz Range 0,02 µT – 12 mT |
Direct measurement method | PN-T-06580-3:2002 Method adapted to the regulated area | Instruction IB-02_Z-04 issue 2 of 31.07.2026 | |
| 16 | Workplace environment − electromagnetic field originating from radiocommunication and anti-theft systems: - handheld radiotelephones, short range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) | Magnetic field strength: in the frequency range from 20 Hz to 20 kHz Range 1,6 A/m – 7 kA/m in the frequency range from 0,3 MHz to 30 MHz Range (0,0105 – 16) A/m in the frequency range from 0,026 GHz to 1,0 GHz Range (0,013 – 4,2) A/m |
Direct measurement method | PN-T-06580-3:2002 Method adapted to the regulated area | Instruction IB-02_Z-04 issue 2 of 31.07.2026 | |
| 17 | Workplace environment − electromagnetic field originating from radiocommunication and anti-theft systems: - handheld radiotelephones, short range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) | Magnetic field strength: in the frequency range 0 Hz in the frequency range from 5 Hz to 400 kHz in the frequency range from 1 GHz to 18 GHz (calculated) |
PN-T-06580-3:2002 Method adapted to the regulated area | Instruction IB-02_Z-04 issue 2 of 31.07.2026 | ||
| 18 | Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy units - physiotherapy diathermy units - magnetic resonance scanners | Electric field strength: in the frequency range from 5 Hz to 400 kHz Range 1 V/m – 50 kV/m in the frequency range from 100 kHz to 18 GHz Range (0,5 – 900) V/m |
Direct measurement method | PN-T-06580-3:2002 Method adapted to the regulated area | Instruction IB-02_Z-02 issue 5 of 31.07.2026 | |
| 19 | Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy units - physiotherapy diathermy units - magnetic resonance scanners | Magnetic flux density: in the frequency range 0 Hz Range 200 µT – 1200 mT in the frequency range from 5 Hz to 400 kHz Range 0,02 µT – 12 mT |
Direct measurement method | PN-T-06580-3:2002 Method adapted to the regulated area | Instruction IB-02_Z-02 issue 5 of 31.07.2026 | |
| 20 | Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy units - physiotherapy diathermy units - magnetic resonance scanners | Magnetic field strength: in the frequency range from 20 Hz to 20 kHz Range 1,6 A/m – 7 kA/m in the frequency range from 0,3 MHz to 30 MHz Range (0,0105 – 16) A/m in the frequency range from 0,026 GHz to 1,0 GHz Range (0,013 – 4,2) A/m |
Direct measurement method | PN-T-06580-3:2002 Method adapted to the regulated area | Instruction IB-02_Z-02 issue 5 of 31.07.2026 | |
| 21 | Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy units - physiotherapy diathermy units - magnetic resonance scanners | Magnetic field strength: in the frequency range 0 Hz in the frequency range from 5 Hz to 400 kHz in the frequency range from 1 GHz to 18 GHz (calculated) |
PN-T-06580-3:2002 Method adapted to the regulated area | Instruction IB-02_Z-02 issue 5 of 31.07.2026 | ||
| 22 | Environment – electromagnetic field (electromagnetic overhead lines without voltage limitation) | Electric field strength with a frequency 50 Hz |
Calculation method | Test procedure PB-02 issue 3 of 31.07.2026 | |
| 23 | Environment – electromagnetic field (electromagnetic overhead lines without voltage limitation) | Magnetic field strength with a frequency 50 Hz |
Calculation method | Test procedure PB-02 issue 3 of 31.07.2026 | |
Reference standards (8)
Instruction IB-02_Z-01 issue 5 of 31.07.2026
Instruction IB-02_Z-02 issue 5 of 31.07.2026
Instruction IB-02_Z-04 issue 2 of 31.07.2026
PN-T-06580-3:2002 Method adapted to the regulated area
Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 151–180
Principles and Methods of Assessing the Working Environment 2016, No. 4 (90), pp. 91–150
Test procedure PB-02 issue 3 of 31.07.2026
Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022 item 2630)